2003-420 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804.5901 (518)761.8201 Community Development-Building&Codes (518)761.8256 rAT ry CERTIFRA I E n0rc 01C' C1UPAN%.j I Pem t Number; P20030420 Date Issued.: Friday,January 16,2004 This is to certify that work requested to be done as shown by Permit Number P20030420 has been completed. Tax Map Number, 523400-296-008-0001-028.001-0000 Location; 16 WAVERLY PI Owner. MICHAELS GROUP LLC THE Applicant; MICHAELS GROUP LLC THE This structure may be occupied as a: By Order of Town Board Fireplace TOWN OF QUEENSBURY Garage-2 Cars Attached Townhouse Director of Building&Code EnforNment TOWN OF ,QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20030420 Application Number: A200301420 Tax Map No: 523400-296-008-0001-028-001-0000 Permission is hereby granted to: MICHAELS GROUP LLC THE For property located at: 16 WAVERLY P1 in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: MICHAELS GROUP LLC THE Garage-2 Cars Attached 10 BLACKSMITH Dr Townhouse $185,900.00 MALTA,NY 12020-0000 Total Value $185,900.00 Contractor or Builder's Name Address - Electrical Inspection Agency NEW YORK BOARD OF FIRE UNDE Plans&Specifications BP 2003-420 Lot 52,House No. 16 Waverly Place Construction of a townhouse with 2 car attached garage as per plot plan and specifications. $318.78 PERMIT FEE PAID-THIS PERMIT EXPIRES: SaturdAy,June 19,2004 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Tiewn o nee ht,June 19,2003 SIGNED BY for the Town of Queensbury. Director of Building&Code Enforcement Building-Permit Application } "I'own of Qucensbury—Dept of Conununity Development, 742 Bay Road,Queensbury,NY (518).7G 1-825b A permit must be obtained before beginning construction. Permit File No. No inspection will be made until applicant has received a Pee Paid $ valid building permit. All applicants' spaces on this Rec. Fee Paid $ application must be completed and must alipcar On the Reviewed By: application form. Applicant: i4v Owner: �(�{� Address: ?address: Phone#(%._e) - [ Phone Property Location: Lot Number: 5',_/ House Number Subdivision Name: Ito.c��, (�2c Tax Map;Number: New Building: residence 1 commercial Estimated Market Value of Construction $ ❑ Addition: residence/ commercial If an Addition, what will use of new addition be?to Alteration: residence/ commercial o No change to exterior size: residence T coni'I o Other work(describe ) Check 0ecuhancylriiformatioll I"Floor 2"` Floor Othci•door `Total Below sq. ft. sq. ft• sq.ft. Square Fect ❑ _Single family dwelling ❑ Two family dwelling Townhouse .a Multifamily dwelling #of units ❑ Office ❑ Mercantile ❑ Manufacturin ❑ 1 car detached garage ❑ 2 car detached garage ❑ 3 car detached garage ❑ I car attached,garage 2 car attached garage 0 3 car attached garage ❑ Storage building- commercial ❑ Storage building- residential ❑ Other Will any second-hand or ungraded lumber lber be used? If so, for what?- W.,i. Type of Heating System: electric/ oil / gas wood /forced hot air./ baseboard./other: Number of'Flrenlaces to be installed C)n16—L Number of Woodsfoi es to be installed �• _ List below the persons)responsible for supervision of work as regards to building-codes: Narile Address Phone Number �;' ' }� Plumber ]Mason IAEW_�_ _ � Electrician �-616- ' �{ l 1—�3°a2Z Declaration: please sign below alter you have careftilly read the slaletnenti To the best of ny knowledge the statements contained in this.application, together•with the plans and specifications submitted, u m are a trite and complete statement of all proposed work to be done on the described prernises and that all- provisions of the I3trilding Code, the Zoning Ordinance and all other laws pertaining to the proposed work sliail be complied with,whether specified or noted,and,that stich work is authorized by the owner. Further, it is understood that Ifwc shall submit,prior to a Certificate of Occupancy or Certificate orcompliance being issued,as requested by the Zoning Administrator or Director ot'Building and Codes,an its atilt Srrrvev by a licensed surveyor;drawn to scale,showing actual location of all new construction Signature: — owner,owner's agent,architect,contractor Fire Marshal's Office Town of Queensbury,742 Bay Road,Queensbury,NY (518)761-8205 Application for Fuel Burning Appliances & Chimneys applicable to solid fuel & vented gas.appliances Date , 20 Si Permit No.(), _0 Application is hereby made to the Building& Codes Office for the issuance of a.Building and Use Permit pursuant to'the New York State Fire Prevention and Building Code. The applicant or owner agrees to comply with all applicable laws, ordinances, regulations, and all conditions that are part of these requirements and also will allow all inspectors to enter premises to perform required inspections. NOTE to applicant: Rough-in and Final Inspections are required. Applicant Information Fuel Burning Appliance Information f (circle appropriate words) Name: 7TAS wood coal pellet gas Fire ace insert Address: 1� Vt�� ���C� '%Xireplace, factory-built: wood as lZ � c�0,4 'Fu Fireplace, masonry: wood gas --T 6rnace: wood gas it Phone: If non-masonary applicance,please provide Owner: Ziem Manufacturer Name: ! i Address: Model Number: Chimney Information Phone: (circle appropriate words) Masonry block bgirk stone Flue the steel size: inches Exact Address: of construction or inst lotion Factory-Built Manufacturer name: Model Number: Note: Listed By: Number: Construction 1 Installation must conform to NYS Fire Prevention &Building Indicate(circle) chimney material: Code. Consult available Town of Queensbury Handouts regarding required inspections. Double wall / Triple wall / Insulated / Direct venting Chimney Liner � Cas�hfer'rs�e�nar�mezxt—�To�zi. of Queensbury, lV"e�-Yor,� , ! Fire Marshal Code# S Collected S Refunded Received ftorn(refunded to): address: A 173 3389 (190) Public Safety A 233 2655 (230) inor S es DATE: yi�,tia�svb�- 7own. �i�c nz C� �, Whit (Appl' ant) 1 Green(Fire Marshal) / Yellow(Bldg.Dept.) / Pink&Goldenrod(Cashier's Dept.) Town of Queensbury Fire Marshal 742 Bay Road Queensbury,NY 12804 761-8205/761-8206 fax 745-4437 Factory Built Gas FireRlace/Stove Inspection Report Notice:New York State requires that all UL Listed,factory built appliances be installed according to the instructions and specifications contained in the Installation Manual accompanying the appliance.No deviation from the manufacturer's instructions or specifications is allowed. Permit# — Schedule Inspection j/I�'��� Time I `UU �'pm anytime Inspecto .Name —6iAddress l Rough In Final Appliance Manufacturer Model# Direct Vent Factory Built Chimney Flue Size Double Wall Triple Wall Insulated Yes No N/A Comments Floor Protection Clearances to Combustibles (all sides) F+irestop(s) Vertical Chase Nall Penetration Vent Clearances to Combustibles Vent/Chimney Termination Chimney height must be 3 feet above roof penetration,2 feet above any combustible construction within 10 feet Gas Shut-Off Valve Combustion Air Hearth extension (if any) Mantel Height above f/p opening 'Fitness Operation Tank Placement(if LP) White—BtdIdWgDept. Yellow Cast er Pink—Fire Marshal Residential Final Inspection Office No. (518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/ J?epar—t: a pin 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: NAME: PERMIT#: LOCATION: DATE: TYPE OF STRUCTURE: Comments N N/A Chimney Ht./"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumb Vent through roof Roof Complete Guard 30 in.or more @ stairs,decks,patios Guard at stairwell at 34 in. or more Guard at deck,porches 36 in.or more Exterior Finish Complete Interior/Exterior Railings 34 in.to 38 in. Platform at all exterior doors Interior Handrails stairs 2 or more risers Gradeaway from foundation 6 in.with 10 ft. Handrail Termination at Newell Post or Wall 8 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18"above grade A/ Gas Furnace shut-off within 30.ft. or within line of site I/ Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating 17' -Low water shut'-off boiler Relief Valve(s)installed Interior privacy/ft-fin/doors/main entrance 36 in. Bathroom/Kitchen watertight Safety glazing Window in stairwells safety glazing Interior Smoke Detectors: Every level: Every Bedroom: Outside every bedroom area: Inter Connected: — / Battery backup: Bathroom Fans,if no window Carbon Monoxide detector Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sf Emergency egress below grade Basement stairs closed rise>4 inches Khour fire door/door closer Garage fire proofing Duct work Scaled properly Attic access 30 in.x 24 in.x 30 in.(ht.)In accessible area Crawl Spaces 18"x 24,"access, 1 sq. ft.-150 sq.ft.vents Iluilqjgg No./Addr ib fr d Final Electrical -.4 4 L11 61r— 11&e—` 1 Site Plan /Varia ce equired Final Survey Plot Plan Vill As Built Sept System/Sewer Dept.Inspection Sticker V� Flood Plain Certification,if required Okay to issue C/C(Cert.Of Compliance) 7 Okay to issue Temporary C 0(Cert.'Of Occupancy) Okay to issue Permanent C 0(Cert. Of Occupancy) L:\Sueliernifi gNvay\Building.Codes.Inspection.FORMS\Res.Final Insp.form 2.doc edited January 28,2003 r Mahoney PO.BOX 7F,7 GLENS FALLS,NEW YORK 1U01 Notify-Plus Inc. 510/793-7780 FAX:5181703.0602 January 12, 2004 - qj Michaels Group 10 Blacksmith Drive Suite 1 Malta, NY 12020 Re; 16 Waverly Place Queensbury, NY To whom it may concern: This letter will confirm testing of the fire alarm system at the above referenced property as at January 12, 2004. At the time of the inspection, all devices were in correct operating order. Should you have,any question;please do not hesitate to contact our office. Sincerely, Edward J. Boeer Installation Supervisor 100'd dSS:E0 170/ZT/T0 Z090S64STS fi}i;oN FiaU0geW o H y t7 r z 0 H H H ; r X H H H H z 0 r C� x o r x z 0 K > 0 �► z �3 z z z z > H H x H ro 0 0 r y g 0 C H 00 ro q n q > 0 0 0 g q q M r N n 0 H y m I G q m M > [ H 0 C r H H H N H x 0 � M H % H W z rH 14, ro n n 0 0 N 0 d z G H H z H z o H H m HNrr > > > g00' c� � �, 00q 000Z �0P4 0 z , N G r ro ro ro 0 0 z 0 P H N z t� ro ro ro H I ro H 0 x = 0 fit C 0 G �7 r N x t� H C 9 dol� n k Cn n N z H t� z z C H 0 0N � rxN bN . 0 0r � � nqH roNc � x roz nc z 0zrxxmor > m0 o y n H N N x N ro N C ro c ro C N N H ro H x H a G 10 H n r C M C G1 • C ro H nz z NW c'n � r � zz0 r H C� „ I N oo C R+ z PN 0 C N Ms OJi � Wu0 Oo zkC iz t-Im ozz H Np'1 N ro oCo[ zw � � v Rough Plumbing / Insulation Inspection Report Office No. (S 18)761-8256 Date Inspection request received: - av Queensbury Building&Code Enforcement Arrive: am/p part: pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: G� -� -:� NAME: (` PERMIT #: LOCATION: INSPECT ON: J I c)4—a-ev.3 TYPE OF STRUCTURE: � �;,� Y N N/A PVC: R-1,R-2,R-3,R4 Drain/Vents . :Cast Iron, Copper Drain/Vent/Comm. Plu mbing Vent/Vents in Place ]Rough Plumbing/Nail Plates. 1 % 'inch,loin:Drain Size Woshin 'Machilie Drain 2 inch min. Head.or Air'SuppIy Test Drain aliid:Vents SPSI`or 101eet above highest ,.,connection for 15 minutes Cleanout 6irery 100 feet/change of direction Water Supply Piping ] �- Cooper Commercial Cfvq CPVC,Pex One and Two-Famil nsul"atloil >kesiileintial Check/Commercial'Check ( rU er Vent,Attic Vent Duct[Hot Water Piping Insulation If required unheated spaces y Cqimbustion Air Supply for Furnace ,�15uct work sealed propLrly/No duct tape 1 C ,S! 1n J • y 1 . COMMENTS: �t . L;\SueHemingway\Building.Codes.Inspection.FORMS\Rough Plumbing Insulation Report.doc November 17,2003 Rough Plumbing / Insulation Inspection Report Office No. (518)761-8256 Date Inspection request received: it� 4 Queensbury Building&Code Enforcement Arrive:-am/um Depart: a1 pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initial NAME: kk,,cj+f�5 PERMIT LOCATION: INSPECT ON: —M&9* TYPE OF STRUCTURE: Y N N/A PVC: R-1,R-2,R-3,R-4 Drain Vents Cast Iron, Copper Drain/Vent Comm. Plumbing Vent Vents in Place Rough Plumbing/Nail Plates Head or Air Supply Test Diain and Vents 5 PSI or 10 ft. above highest Connection for 15 minutes Watd upply Piping e opper Commercial per,CPVC,Pex One&Two Family YCOP11 Ansulation/Residential Check/Commercial Check -Proper Vent,Attic Vent Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for furnace Duct Work Sealed Properly COAMENTS: �L.\SueHemingway\Building.Codes.Inspection.FORMS\Rough Plumbing Insulation Report.doc January 29,2003 Framing /Firestopping Inspection Report / Office No.(518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/p ep rt �m 742 Bay Road,Queensbury,NY 1.2804 Inspector's Initials: NAME: M Je PERMIT#: LOCATION: f ' Z�r�_ - INSPECT ON: !l TYPE OF STRUCTURE: Y N N/A COMMENTS g � Jack Studs 1 Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. ,Headroom 6 ft. 8 in. Stairwells 3 6 in.or more Headroom 6 ft. 8 in. Notches/Doles/Bearing Walls Metal Strapping for Notches Top Plate 1 V2(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1,2,3 hour Fire wall 2, 3,4 hour Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side t/2 inch or 5/8.inch Type X Garage-side 5/8.inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) -5.7.sf above/below grade 5.0 sf grade L:1SueHemingway\Building.Codes.Inspection.FORMS1Framing Firestopping Inspection keport.doc January 28,2003 Framing / Firestopping Inspection Report Office No. (5 18)761-8256 Date Inspection request received: /hA ) Queensbury Building&Code Enforcement Arrive: am/ am/pm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials:) 'NAME: PERMIT#: LOCATION: INSPECT ON: TYPE OF STRUCTURE: Y N N/A Framing COMMENTS aml Jac tads Headers Bridging n racing Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in.or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate I Y2(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq.ft.floor trusses Anchor Bolts 6 ft.or less on center Ice and snow shield 24 inches from wall Fire separation 1,2,3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side V7.inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above below grade 5.0 sf grade Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: -)-A-o Queensbury Building&Code Enforcement Arrive: am/ am/pm . 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: NAME: PERMIT #: C% - LOCATION: INSPECT ON: TYPE OF STRUCTURE: Y N N/A PVC: R-1,R-2,R-3,R4 Drain/Vents Cast Iron,Copper Drain/Vent/Comm. VpPjumbing Vent/Vents in Place, Rough Plumbing/Nail Plates I % inch min.Drain Size, Washing Machine Drain 2 inch min. Head or Air Supply Test Drain and Vents' 5 PSI or 10 feet above highest connection for 15 minutes Cleanout every 100 feet/change of direction Water Supply Piping Cooper Commercial Cooper,CPVC,Pex One and Two-Family Insulation/Residential Check/Commercial Check Proper Vent,Attic Vent Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly No duct tape COMMENTS: L:\SueHemingway\Building.Codes.Inspection.FORMS\Rough Plumbing Insulation Reportdoc November 17,2003 Town of Quecusbury Fire Marshal 742 lay Road Queensbury,NY 12804 761-8205/761-8206 fax 7454437 FactoKy]Built G ire lase/ tove Ins ection Re ort Notice:New York State requires that all IJL Listed,fa Cory built appliances be installed according to the instructions and specifications contained in the Installation Manual accompanying the appliance.No deviation from the manufacturer's instructions or specifications is allowed. Permit# 13 D.& Schedule Inspection 101A L�03TDne. _am Spmanytime Inspector Name l Address 1 tS� i ough in +final ApplianceManuf turer Model# � ��� ���t � ��A'o� 3 Direct Vent Factory Built Chimney Flue Size Rouble Wall Triple Wall Insulated Yes No NIA Comments Floor Protection Clearances"to Combustibles(all sides) Pirestop(s) vertical Chase Wall Penetration Vent Clearances to Combustibles Vent/Chimney Termination Chimney height must be 3 feet above roof penetration;2 feet above any combustible construction within 10 feet Gas Slant-Off Valve Combustion Air Hearth Extension(if any) Mantel Height above f/p opening Witness Operation Tank Placement{if LP) White—Building Dept. yellow Oust er Pink—Tire Marshal a6,cw /� Rough Plumbing I Insulation Inspection Report Office No. (518)761-8256 Date Inspection request received- Queensbury Building&Code Enforcement Arrive: am/ (,,part: 47 742 Bay Road, Queensbury,NY 12804 Inspector's Initials:4�f 7 PM NAME: PERMIT #: , LOCATION: INSPECT ON: TYPE OF STRUCTURE: Y N N/A PVC: R-1,R-2,R-3,R4 Drain/Vents Cast Iron,Copper Drain/Vent/Comm. UIPlain 9 Vent/Vents in Place -ail-I'lates I 1/2,inch nun. Drain Size YA(ashing Machine Drain 2 inch min. Mead or Air Supply Test Drain and Vents- 5 PSI or 10 feet above highest connection for 15 minutes Cleanout every 100 feet/change of direction Water Supply Piping Cooper Commercial Cooper,CPVC,Pex One and Two-Family Insulation/Residential Check/Commercial Check Proper Vent,Attic Vent Duct/.Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: L:\SueHemingway\Building.Codes.Inspection.FORMS\Rough Plumbing Insulation Report.doc November l7,2003 Framing/Firestopping Inspedion Re-port Office Na. (518) 761-8256 Date Inspection requ cei rcei a Queensbury Building&Code Enforcement Arrive: Ut D a It: am/ 742 Bay Road,Queensbury,NY 12804 Inspector's Initial . 7, PERMIT#: LO,NAME: Cka-S GYC LOCATION: 1 ((2 A rU Row- INSPECT ON: TYPE OF STRUCTURE: Framing Y N '7 NIA COMMENTS Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate I V2(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq.ft. floor trusses Anchor Bolts 6 ft. or less on center Ke and snow shield 24 inches from wall Fire separation 1,2, 3 hour Fire wall 2,3,4 hour Firestopping Penetration scaled 16 inch insulation in cavity min. Garage Fire Separation House side Y2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7*sf above below grade 5.0 sf grade L:\Suel-Iemingway\Building.Codes.Inspection.FORMSTraming Firestopping Inspection Report.doc January 28,2003 Foundation Inspection Report 1 Office No.(518)761-8256 Date Ins ection r q t rec ive . Queensbury Building&Code Enforcement Arrive: a De a m 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initial NAME: IT#: 4),b LOCATION: INSPECT ON: —( TYPE OF STRUC �� v Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation J Wallpour Reinforcement in Place Foundation Dampproofing Foundation l Waterproofing Type of Dampproofing f Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width ches above footing 6 mil poly for wet areas under slab Bacxfill Approval Plumbing Under Slab PVC I Cast I Copper Foundation Insulation Interior 1 Exterior R- Rough Grade 6 inch drop within 10 ft. L:\SueHemingway\Building.Codes.Inspection.FORMS\Foundation Inspection Report.doc January 28,2003 -Am Foundation Inspection Report Office No.(5 118)761-825 6 Date Inspection request received: P//Jl Queensbury Building&Code Enforcement Arrive: am/p am/pm ": j oe/ 742 Bay Rd., Queensbury,NY 12804 Inspector's Initial Depart: NAME: "J.1 clxadly C",p PERMIT#: cPOel,3 Y LOCATION: 14 4)R wo-, V INSPECT ON: TYPE OF STRUCTURE: - Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Foundation Darappro6fing Foundation/Waterproofing Type of Dampproofing/Waterproofin*g Footing Drain Daylight or Sump VFooting Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab 44'Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. LASueHemingway\B ui Wing,Codes.Inspection.rORMS\Fouiidation Inspection Report.doc January 28,2003 Foundation Inspection Report Office No. (518)761-8256 Date Inspection req st ec ....................... Queensbury Building&Code Enforcement Arrive: p Depart: Z��6aig�—m � 742 Bay Rd., Queensbury,NY 12804 Inspector's Ini is NAME: RMIT#: 03 —_q an LOCATION: lP INSPECT ON: TYPE OF STRUCTU Comments N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Found �n Darapproofing X6undation/Waterproofing Type of Dampproofing ftroofiri Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L;\SueHemingway\Building.Codes,Inspection.FORMS\Fouiidadon Inspection Report.doc January 28,2003 Foundation Inspection Report Office No. (51-8)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: - am/p D rt: am/pm 742 Bay Rd,, Queensbury,NY 12804 Inspector's Initials: NAME: 1G PERMIT#: L4 d C> LOCATION: cv,j: INSPECT ON: 7 rs 2 TYPE OF STRUCTMf: Comments Y N N/A- Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Foundation Darapproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil of for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. LASuefferningwayNBuilding.Codes.InspectionYORMSTounda don Inspection Report.doc January 28,2003 Permit Number REScheck C6mpliance Certificate Checked By/Date New York State Energy Conservation Construction Code REScheekSoftware Version 3.5 Release lc Data filename:F:\SHARE\Design\Energy Calc\WAVERLY PLACE\16 Woodruff.cck TITLE:WP 322,Woodruff COUNTY:Warren STATE:New York HDD:7635 CONSTRUCTION TYPE:Detached I or 2 Family BEATING TYPE:Non-Electric DATE: 07/09/03 DATE OF PLANS:July 7,2003 PROJECT INFORMATION: 16 Waverly Place Queensbury,N.Y. 12804 COMPANY INFORMATION: The Michaels Grop 10 Blacksmith Dr. Malta,NY 12020 NOTES: All options are included. Silverline 2900 windows COMPLIANCE:Passes Maximum UA=428 Your Home UA=415 3.0%BetterThan Code(UA) Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA Ceiling 1:Raised or Energy Truss 1422 30.0 0.0 46 opt.Mbr bay ceiling:Raised or Energy Truss 17 30.0 0.0 1 opt.Mbr bay wall: Wood Frame, 16"o.c. 18 19.0 0.0 1 opt.Pining bay ceiling:Raised or Energy Truss 19 30.0 0.0 1 opt.Dining Bay wall:Wood Frame, 16"o.c. 15 19.0 0.0 1 opt.Brkfst bay ceiling:Raised or Energy Truss 19 30.0 0.0 1 opt Brkfst bay wall:Wood Frame, 16" o.c. 15 19.0 0.0 1 1st R'walls:Wood Frame, 16"o.c. 1534 19-.0 0.0 73 2x opt.Mbr(AG):Vinyl Frame,Double Pane with Low-E 25 0.400 10 Ix opt.Mbr(AF):Vinyl Frame,Double Pane with Low-E 32 0.400 13 Ix Bed#2(A):Vinyl Frame,Double Pane with Low-E 34 0.400 14 Living#17:Glass 54 0.350 19 Ix Living(D):Vinyl Frame,Double Pane with Low-E 9 0.400 4 Ix opt.Living(D):Vinyl Frame,Double Pane with Low-E 9 0.400 4 Ix Dining(L):Vinyl Frame,Double Pane with Low-E 30 0.400 12 2x Dining(K):Vinyl Frame,Double Pane with Low-E 20 0.400 8 Ix opt.Brkfst(L):Vinyl Frame,Double Pane with Low-E 30 0.400 12 2x opt.Brkfst(K):Vinyl Frame,Double Pane with Low-E 21 0.400 8 Foyer#IA: Solid 29 0.350 10 Laundry#20: Solid 19 0.240 5 2nd floor walls: Wood Frame, 16" o.c. .910 19.0 0.0 50 Ix Foyer(AH):Vinyl Frame,Double Pane with Low-E 11 0.400 4 Ix Loft(AR):Vinyl Frame,Double Pane with Low-E 32 0.400 13 lx Bed#3(A):Vinyl Frame:Double Pane with Low-E 34 0.400 14 Basement Wall 1: Solid Concrete or Masonry 1295 0.0 11.0 84 Wall height: 7.6' Depth below grade: 6.6' Insulation depth:6.0' 3x Bsmnt windows:Wood Frame,Double Pane with Low-E 5 0.520 3 Bsmnt opt.Mbr.bay wall: Solid Concrete or Masonry 13 0.0 11.0 1 Wall height: 7.6' Depth below grade:6.6' Insulation depth:6.0' Bsmnt opt.Dining bay wall: Solid Concrete or Masonry 13 0.0 11.0 1 Wall height: 7.6' Depth below grade: 6.6' Insulation depth:6.0' Bsmnt opt.Brkfst bay wall: Solid Concrete or Masonry 13 0.0 11.0 '1 Wall height:7.6' Depth below grade: 6.6' Insulation depth:.6.0' Furnace 1:Forced Hot Air,80 AFUE COMPLIANCE STATEMENT: The proposed building represented in this document is consistent with the building plans, specifications,and other calculations submitted with this permit application. The proposed systems have been designed to meet the New York State Energy Conservation Construction Code requirements. When a Registered Design Professional has stamped and signed this page,they are attesting that to the best of his/her knowledge,belief,and professional judgment,such plans or specifications are in compliance wit this Code. Builder/Designer— Date -711 REScheck Inspection Checklist. New York State Energy Conservation_ Construction Code ` REScheckSoftware Version 3.5 Release lc DATE:07/09/03 TITLE:WP 322 Woodruff Bldg. Dept. Use Ceilings: [ ] 1. Ceiling 1:Raised or Energy Truss,R-30.0 cavity insulation Comments: Insulation must achieve full height over the plate lines of exterior walls. [ ] 2. opt.Mbr bay ceiling:Raised or Energy Truss,R 30.0 cavity insulation Comments: Insulation must achieve full height over the plate lines of exterior walls.. [ ] 3. opt.Dining bay ceiling:Raised or Energy Truss,R-30.0 cavity insulation Comments: Insulation must achieve full height over the plate lines of exterior walls. [ ] 1 4. opt.Brkfst bay ceiling:Raised or Energy Truss,R-30.0 cavity insulation Comments: Insulation must achieve full height over the plate lines of exterior walls. Above-Grade Walls: [ ] 1. opt.Mbr bay wall:Wood Frame, 16"o.c.,R-19.0 cavity insulation Comments: [ ] 2. opt.Dining Bay wall:Wood Frame, 16"o.c.,R 19.0 cavity insulation Comments: [ ] 3. opt.Brkfst bay wall:Wood Frame, 16"o.c.,R-19.0 cavity insulation Comments: [ ] 4. 1st fl walls:Wood Frame, 16"o.c.,R-19.0 cavity insulation Comments: [ ] 5. 2nd floor walls:Wood Frame, 16"o.c.,R-19.0 cavity insulation Comments: Basement Walls: [ "] 1. Basement Wall 1: Solid Concrete or Masonry,7.6'ht/6.6'bg/6.0'insul, R-11.0 continuous insulation Comments: Exterior insulation must have a rigid,opaque,weather-resistant protective covering that covers the exposed(above-grade)insulation and extends at least 6 in.below grade. [ ] 2. Bsmnt opt.Mbr.bay wall: Solid Concrete or Masonry,7.6'ht/6.6'bg/6.0'insul, R-I1.0 continuous insulation Comments: Exterior insulation must have a rigid,opaque,weather-resistant protective covering that covers,the exposed(above-grade)insulation and extends at least 6 in:below grade. [ j 1 3. Bsmnt opt.Dining bay wall: Solid Concrete or Masonry,7.6'ht/6.6'bg/6A'insul, R-11.0 continuous insulation Comments: Exterior insulation must have a rigid,opaque,weather-resistant protective covering that covers the exposed(above-grade)insulation and extends at least 6 in.below grade. C ] 4. Bsmnt opt.Brkfst bay wall: Solid Concrete or Masonry,7.6'ht/6.6'bg/6.0'insul, R-11.0 continuous insulation Comments: Exterior insulation must have a rigid,opaque,weather-resistant protective covering that covers the exposed(above-grade)insulation and extends at least 6 in.below grade. Windows: 1. 2x opt.Mbr(AG):Vinyl Frame,Double Pane with Low-E,U-factor: 0.400 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: 2. Ix opt.Mbr(AF):Vinyl Frame,Double Pane with Low-E,U-factor: 0.400 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: 3. Ix Bed#2(A):Vinyl Frame,Double Pane with Low-E,U-factor:0.400 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: 4. Ix Living(D): Vinyl Frame,Double Pane with Low-E,U-factor:0.400 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: 5. Ix opt.Living(D):Vinyl Frame,Double Pane with Low-E,U-factor:0.400 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: 6. Ix Dining(L):Vinyl Frame,Double Pane with Low-E,U-factor:0.400 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: 7. 2x Dining(K):Vinyl Frame,Double Pane with Low-E,U-factor:0.400 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: 8. Ix opt.Brkfst(L): Vinyl Frame,Double Pane with Low-E,U-factor:0.400 For windows without labeled U-factors,describe features: #Panes .Frame Type Thermal Break? Yes No Comments: 9. 2x opt.Brkfst(K):Vinyl Frame,Double Pane with Low-E,U-factor:0.400 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: 10. lx Foyer(AH):Vinyl Frame,Double Pane with Low-E,U-factor:0.400 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: 11. Ix Loft(AR):Vinyl Frame,Double Pane with Low-E,U-factor:0.400 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: 12. Ix Bed#3 (A):Vinyl Frame:Double Pane with Low-E,U-factor:0.400 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: . 13.. 3x Bsmnt windows: Wood Frame,Double Pane with Low-E,U-factor: 0.520 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: Doors: 1. Living#17:Glass,U-factor:0.350 Comments: 2. Foyer#lA: Solid,U-factor: 0.350 Comments: [ ] I 3. Laundry#20: Solid,U-factor:0.240 I Comments: Heating and Cooling Equipment: [ ] I 1. Furnace 1:Forced Hot Air, 80 AFUE or higher Make and Model Number I' Air Leakage: [ ] I Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage must be sealed. [ ] I Recessed lights must be 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly I with a 0.5"clearance from combustible materials.If non-IC rated,the fixture must be installed with a 3"clearance from insulation. I Vapor Retarder: [ ] I Required on the warm-in-winter side of all non-vented framed ceilings,walls,and floors. . Materials Identification: [ ] I Materials and equipment must be installed in accordance with the manufacturer's installation instructions. [ ] I Materials and equipment must be identified so that compliance can be determined. C ] I Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. [ ] I Insulation R-values;glazing U-factors,and heating equipment efficiency must be clearly marked on the building plans or specifications. I Duct Insulation: [ ] I Supply ducts in unconditioned attics or outside the building must be insulated to R 11. [ ] I Return ducts in unconditioned attics or outside the building must be insulated to R-6. Supply ducts in unconditioned spaces must be insulated to R-11. [ ] I Return ducts in unconditioned spaces(except basements)must be insulated to R-2. Insulation is not required on return ducts in basements. I I Duct Construction: [ ] I All joints,seams,and connections must be securely fastened with welds,gaskets,mastics (adhesives),mastic-plus-embedded-fabric,or tapes. Duct tape is not permitted. Exception:Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in.w.g.(500 Pa). [ ] I Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions. [ ] I Cooling ducts with exterior insulation must be covered with a vapor retarder. . [ ] I Air filters are required in the return air system. [ 1 I The HVAC system must provide a means for balancing air and water systems. I I 'Temperature Controls: [ ] I Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space I temperature set point of the largest zone. I Electric Systems: [ ] I Separate electric meters are required for each dwelling unit. i Fireplaces: [ ] I Fireplaces must be installed with tight fitting non-combustible fireplace doors. C ] I Fireplaces must be provided with a source of combustion air,as required by the Fireplace construction provisions of the Building Code of New York State,the Residential Code offew York State or I the New York City Building Code,as applicable. I Service Water Heating: [ ] I Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the I water heater has an integral heat trap or is part of a circulating system. [ ] I Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: [ ] Insulate circulating hot water pipes,to the levels in Table 1. Swimming Pools: [ ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20% j of the heating energy is from non-depletable sources. Poolpumps require a time clock. Heating and Cooling Piping Insulation: [ ] HVAC piping conveying fluids above 105 OF or chilled fluids below 55 T must be insulated to the levels in Table 2. Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. : Insulation Thickness in Inches by Pipe Size's Heated Water Non-Circulating Runouts Circulating Mains and Runonts . Temperature(F) _Up to I" "Up.to 1.25" 1.5"to 2A" Over 2" 170-180 0.5 1.0 1.5 2.0 140460 0.5 0.5 1.01 1.5 100-130 0.5 '0.5 0.5 Lo Table 2: Minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range F 2"Runouts l"and Less 1.25"to,2" 2.5"to 4" Heating Systems - Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5- Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water,Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only) Project NameL /ll/i BP# Q5. , $ Address: o � t t , Building Pen-nit Submission SFD Checklist 2-Family All items below must be checked either yes,no or not applicable prior to-submission of any building permit to the Town of Queensbury Building Department If any of the below items:are lacking,the permit will not be accepted until such time as.the application is deemed complete for submission: 1. Building Permit Application Gompleted ............... ...... ...... 10_5�s ❑no. ❑n/a 2. EnergyFonn or Checkmate Energy Code Compliance Form Complete.. ❑no ❑nla (2 copies) 3. Energy Gode Inspector's Report from-Clrejd&te Program.. ...... ...... :. Q no F1'rr/a (2 copies) t if a hca le ... no nla 4. Septic application completely filled out( pp ) ❑yes [] ❑ 5. Solid Fuel Burning or Gras Appliance Form... ...... ... ...... ...... ...... ... ... .❑yes Qno �,❑'nIa 6. Electrical Inspection Form... ...... .... ... ... ❑ a 7. Two(2)complete sets of structural drawings......... ... ...... ... ... ...... ... ... . yes ❑no ❑ula a)-floor plan;b);foundation plan;c)cross sections:d)elevations; e)window and door'schedule 8. Two(2)site plans showing location of the structure to be built,...... ... ... - ❑iro 'Elh/a location of well or water lines location of septic systems or sewer line. 1. Setbacks from property linen to new structure......... ...... ............ ......- yes Ono Onla lo. Setbacks to neighboring wells and septic systems,including onsite well.... IrTyes. ❑no ❑nla and septic systems (if applicable) 11. Driveway Permit.. ... ... ... ... .:............ ..................... ...... ❑ a Ono Dater " 69 _ Staff Initial: I.\SueHemiugway\BuRding.Pernit.FORMS\Generic(:iecklisedoe. Jmuary28,2003 ' Residential Plan Review: One&Two Family Dwellings r Check Y/N/N/A 2)Full sets of plans Over 1,500 sq. ft.—stamped Design loads on plans: 90 wind Floor Loads 40 psf 70 ground snow load Sleeping areas and Attics 30 psf Calculations: Window Schedule with glass size Door Schedule/Main Entrance 36"Door Emergency escape for Bedrooms and Habitable Space - /` Above/Below grade,5.7 sq.ft. / Grade,5.0 sq.ft. V 24"(h)x 20"(w)min. 44"Max.Height above floor Residential Check paperwork compliance and inspectors checklist: OK Vertical Rebar as required by code/Anchor Bolts%x 7 6'O.C. Dampproofing/Waterproofing materials on.plans Foundation Drainage on plans,if required 6;:Drop in 10' Exterior Grade Framing cross section for each roof line,Vertical Fire Stopping every 10'.where required Ice and Snow shield 24"inside exterior wall/Proper Vent,Attic Vent , Platforms at exterior doors Stairway headroom 6 ft. 8 in.all stairs 36"Width Stair,run and rise Winder run and.-rise Spiral not allowed from 2" story moke,detectors battery backup,and proper.location throom Fixtures proper clearance all,width,3,6"`min. andrails more than one riser on open"sides Railing and.Guards>30"/Basement Stairs included/Closed Risers more.than 4".in height Safety. Glazing Notes for required areas arage Fire Separation Garage Floor Sloped Attie Access Roof over 30"—22"x 30" Crawl Spaces-18"x 24"Access Carbon Monoxide Detector lowest sleeping level Soil Test Results,if required Septic to well,or'water line separation All paperwork signed G-� 14 O z L) a� a � W g8'644 m W a; c H,•a m cr IPA 0) � '�I o IVARigtx —o fill lot@ $a ��� eN CQ 0 �ECk a uuN r 3 2003 � TO[1V AI I F OUE '^ ENSBURy z ;�-- NG A;r11D CODE i � z � C � MAP REFERENCE: WAVERLY PLACE 5UBDIV15ION DATED AUGUST 24, 2000 LAST REVISED JANUARY 1g. 2001 BY VAN DU5EN + 5TEVE5 LAND SURVEYORS. LLG S89017'53"E 119.86' 3a A2 > 0 \� 51 m N 0 5,°?�M� ` 8,202 sq.ft. FFN 0.19 acres ?0RG" w oww 0 3A Q3, 720 33 50 S l � 0 52 7g• f'n 33 5�O\z 8,194 sq.ft. w000 oUSti 0.19 acres ASPS PLC � �� 0 CP 2 0•�` °3� 0 9$ 0 • S5b Zi/ s �1 Q. - I a t-+L Datei DECEMBER 9, 2003 "UNAUTHORIZED ALTERATION OR ADDITION A SURVEY Map of a Survey made for Scale 1"=20' MAP OF A LICENSED S LAND SURVEYORS SEAL IS A VIOLATION TION OF SECTION 7209,SUB-DINSICN 2,OF THE NEW YORK STATE EDUCATION LAW." 'ONLY COFIE5 FROM THE ORIGINAL OF TH15 5URVEY MARKPD N"TH AN O'JGINA,OF TH!LAND 5URVVO,R5 S t �T /� s SEAL SHALL BE CONSIDERED TO BE VALID RUE TH TH ' THE M I C HA E L S GROUP S - 1 C V C "CERTIFICATIONS INDICATED HEREON SIGNIFY THAT THIS SURVEY WAS PREPARED IN ACCORDANCE W1 TH THE EXISTING CODE OF PRACTICE FOR LAND SURVEYORS ADOPTED Land Surveyors LA THE NEW YORK STATE ASSOCIATION OF PROFESSIONAL LAND SURVEYORS.SAID CERTIFICATIONS SHALL RUN ONLY 70 THE PERSON FOR WHOM THE SURVEY IS PREPARED,AND SHEET 1 OF 1 ON HIS BEHALF TO THE TITLE COMPANY,GOVERNMENTAL AGENCY AND LENDING INSTITUITION LISTED HEREON,AND Town of Queensbury, Warren County, New York 169 Havlland Road Queensbury, New York 12804 TO THE A551GNEE5 OFT HE LENDING IN5TIP1TION." N.�iGhaels (518) 792-8474 New York Lie. No. 50135 NO. DATE DESCRIPTION DWG. NO. g9312-51-52