2007-614 TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development - Building & Codes (518) 761-8256
CERTIFICATE OF OCCUPANCY
Permit Number: P20070614 Date Issued: Tuesday, December 04, 2007
This is to certify that work requested to be done as shown by Permit Number P_20.070614
has been completed.
Location: 118 QUAKER Rd
Tax Map Number: 523400-302-007-0001-012-000-0000
Owner: QUEENSBURY QUAKER, L.L.C.
Applicant: QUEENSBURY QUAKER, L.L.C.
This structure may be occupied as a:
Commercial Alteration By Order of Town Board
TOWN OF QUEENSBURY
Issuance of this Certificate of Occupancy DOES NOT relieve the I ® "�
property owner of the responsibility for compliance with Site Plan, .;
p�r
Variance, or other issues and conditions as a result of approvals by the Director of Building&Co a Enforcement
Planning Board or Zoning Board of Appeals.
TOWN OF QUEENSBURY
f,
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development- Building&Codes (518) 761-8256
BUILDING PERMIT
Permit Number: P20070614 Application Number. A20070614
Tax Map No: 523400-302-007-0001-012-000-0000
Permission is hereby granted to: QUEENSBURY QUAKER, L.L.C.
For property located at: 118 QUAKER Rd
in the Town of Queensbury,to construct or place
at the above location in accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. Type of Construction Value
Owner Address: QUEENSBURY QUAKER, L.L.C. -.
90 STATE St Suite 1411 Commercial Alteration $60,000.00
ALBANY,NY 12207-0000 Total value $60,000.00
Contractor or Builder's Name/Address Electrical Inspection Agency
Plans &Specifications
2007-614
1825 SQ FT COMMERCIAL ALTERATION-AMERICAN GENERAL FINANCE
$219.00 PERMIT FEE PAID- THIS PERMIT EXPIRES: Sunday, October 05,2008
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at the To z
ay October 05,2007
zVW
SIGNED BY for the Town of Queensbury.
Director of Building&Code Enforcement
OFFICE USE ONLY `-'I r: 7
2 - ,
TAX MAP NO. PERMIT NO, l ( "` "'+'"�
FEES: PERMIT C EATION ENGINEER(fi appli a le IN . T 2ao
10
BUILDING&CODES
PRINCIPAL STRUCTURE:
APPLICATION FOR ZONING APPROVAL & BUILDING PERMIT
A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION. APPLICATION IS SUBJECT TO
REVIEW BEFORE ISSUANCE OF A VALID PERMIT FOR CONSTRUCTION.
APPLICANT/BUILDER: UA1 _ OWNER: C v 4ec-CsZJ e¢n5T�!--�
ADDRESS: ADDRESS: qo
PHONE NOS. PHONE NOS. -`f 70—ZZ
SGZ_- 6)(9C f
CONTACT PERSON FOR BUILDING & CODES COMPLIANC PHONE: 70
LOCATION OF PROPERTY: �ya •��G� �J ��
SUBDIVISION NAME:
PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW:
CHECK ALL THAT 0 1% a o H
w u_
APPLY TO YOUR z0 t= O 0 U U) (n �
CO
PROJECT" n.
0 W _j 0 =
w � w � " wu_ w ¢ Oz
o U. C1 z CY F=- � 01= � w -
z ¢ ¢ :- Cl) c14 cn O u_ I- u- (L _ 06
SINGLE FAMILY
TWO-FAMILY
MULTI-FAMILY
(NO.of UNITS )
TOWNHOUSE
BUSINESS OFFICE
RETAIL-
MERCANTILE e,
FACTORY OR
INDUSTRIAL
ATTACHED
GARAGE(1,2,3)
OTHER
IF COMMERCIAL OR INDUSTRIAL-NAME~ OF BUSINESS: fA-V `'f%aeA Ge&E? t J:: �X�iC� Jt C,
ESTIMATED CONSTRUCTION COST: FUEL TYPE:
HEAT TYPE: *HOW MANY FIREPLACE(S): O AND/OR WOODSTOVES(S):
ZONING CATEGORY: ARE THERE WETLANDS ON THIS SITE?
IS THIS A HISTORIC SITE? Iy f)
PROPOSED USE OF BUILDING OR ADDITION: r12,
! !� ' Z
*Please complete a separate Application for"Fuel Burning Appliances& himneys" available in our office
B 3-LGL 11-05
Town of Queensbury- Community Development Office * 742 Bay Road, Queensbury, NY 12804
ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN? ►V C7
ARE THERE EASEMENTS ON PROPERTY? ��
1 acknowledge no construction activities shall be commenced prior to issuance of a valid
permit. I certify that the application, plans, and supporting materials are a true and
complete state me nt/d escri ptio n of the work proposed, that all work will be performed in
accordance with the NY State Building Codes, local building laws and ordinances, and in
conformance with local zoning regulations. I acknowledge that prior to occupying the
facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand
that I/we are required to provide an as-built survey by a licensed land surveyor of all newly
constructed facilities prior to issuance of a certificate of occupancy.
I have read and agree to the above.
Signed
Director of Building &Codes: 761-8256 (for questions regarding Building Permits, construction
codes or septic systems)
Zoning.Ad min istrator: 761-8218 (for questions regarding required permits, the permit process,
application requirements or to schedule an appointment)
Permission is hereby granted to the above ' S This application / proposed action described
01 Applicant to erect or alter the building ; herein is found to be in accordance with the
described herein in accordance with said zoning Laws of the Town of Queensbury. S
Application: 01
, 11
11
10 0 00
0
BUILDING COD APPROVAL S ZONING APPROVAL 00
DATE DATE
0
QUESTIONS? CALL 761-8256 OR EMAIL
codesCa_Dgueensbury.net
Office Use Only VISIT OUR WEBSITE FOR MORE INFORMATION
www.gueensbury.net
Operating Permit Issued: Yes No
Occupancy Type:
Construction Classification:
Assembly Occupancy Limit:
Special Conditions: vh,
Town of Queensbui-y• Community Development Office • 742 Bay Road, Queensbuny, NY 12804
r
TIRE MARSHAL'S OFFICE
Town of Queensbury
742 Bay Road, Queensbury, NY 12804
"Home of Natural Beauty... A Good -Place fo Live ".
PLAN REVIEW
American General Finance
2007-614'
10/12/2007
I reviewed the recently submitted drawings for the above project, and°offer
the following:
1) -Please indicate on drawings locations of emergency lighting
2) Pleaser indicate on drawings exit signage w/battery backup
3) Fire.extinguisher locations to be determined
4) NFPA 13 compliance letter;required for sprinkler modifications
5) Any-changes to HVAC equipment-may require duct detection and fire
alarm compliance
: . Fire Marshal ,
Michael J Palmer
742 Bay Road
Queensbury NY 12804
518 7-61 8206
firemarshal@queensbu'ry.net
Fire Marshal 's Office Phone: 518-761-8206 Fax: 518-745-4437
firemarshalQqueensbuty.net www.queensbury.net
0
a
ID
PLEASE VERIFY ALL DIMENSIONS a
ALL INTERIOR DOORS MUST BE 3'
A 3
o
N �
N N
O
y
1
N wux-oFs �-
CWJA6Ratr n �,
v �1
co T
COMMA- �
b
Ln
]E3
. b
V
o
m
IL
m
T-2.112`
e
N
O
Ol
AGF—QUEENSBURY, NY ,•
TYPE—OPEN 1,825 SQ.FT. N
NOT TO SCALE q
ueensbury H 4 EMPLOYEES N
B-iO-O7
DISTRICT MGR SIGN OFF
�a-
a
PLEASE VERIFY ALL DIMENSIONS
ALL INTERIOR DOORS MUST BE 3' � a
a 3
o -
N �
o r
A
O� A� ty O
9'�V" 5'-2" -7" e ti
-I T
10'-011—
I ,
a0 n
T
S
N
O
0
_1
Dedleated Outlet
®�Deditated Quad Outlet
:=voias/bato outlet El v I
2-D vm Outiet 2—Ovad oullou
2-Quad Outlet tar Pha»Bernd
®Io°wdsao d a,uat
m
m
m
171-2 J 12"
e
AGF—QUEENSBURY, NY
TYPE--OPEN � 1,825 SQ.FT. N
NOT TO SCALE queensbury N TM IG' 4 EMPLOYEES
B-10-07
DISTRICT MJGR SIGN OFF
t
` Received et: 5:26PM, 8/14/2007'
Aua-14-07 04:23PO Frat-AOF HWS + T-909 P.04/06 F-322
AMERICAN GENERAL FINANCLtL SERVICES-FDn I SPECIFICATIONS
VANILLASHELL
➢ Demo walls as needed to adhere to vanilla box or tenant's layout.
3 Floors shall be level,finished smooth concrete ready for floor coveting.
>: HVAC system shall be completed including all ductwotk,electrical camp onam,registers,controls,thermostat in
office area and grills approprlawly placed thmughour the premises providing a miairmart of 1 inn per 400 N.it:
(fIVAC to be included in restroom(s)).
Plumbing shall provide good water and sewer services and shall comply with all applicable legal requirements.Ia
addition to"rows,plumbing m include piping to location outside oiresnoom to location where tenant will install
sink and cabinets.
➢ Restroom(s)shall be built in a back wall location,shall comply with all applicable govemnaerM4 codes and ADA
requirements and shall include completed phaohing and sewer,toilet,sink with bot end cold water,grab bats,mdet
paper holder,papertowel dispenser,rheas and floomig.Exhaust faa shall be included.The walls shall be
sheettocked,taped,finished,sanded and ready for Terrain's paint (One or two resroams per code.)
➢ Demising walls exreaded to roofdeck.All perimeter walls constructed,drywaRed,taper!,sanded,and ready forpamt
T Drop ceiling-new tiles shall be installed complete with standard white 2X2 or 2X4 acoustical dies and new or freshly
painted grid.
➢ Lighting shall be four(4)]amp 2 x 4 messed Ught fixtures with diffuses with at least one(1)fixture per 80 square feet
otfthe leased prertdsm complete withlaraps.
➢ Completed 150 amp elecafcal system m space. Service panel shall be located on reazwan of leased premises.Duplex
wall oudcts per code.
➢ Phone service to be brought into space ro the back wall of space,
➢ Rear and from eutrance%edt doors,exit lights and emergency lights installed per code.
D Ennyway completely f aA04
➢ Landlord shall install far sprinkler systems per code as needed
AMERICAN GENERAL FINISH SPECH7CATION/DETAH,
• Consauct wall,if ruwe:dst with door to separate front office area&omback mom.(see layout)
• Consnact approximate 10'X IO'conference%losing room(with adequate HVAC dnetwodddiffuser).This office
needs a 4'X 4'window and a medium-grade,prehung,hollow-core,painted door.
• Install 4'X 6'plywood board(if noaxtdstent)at eye level for n w r ing phone equipment(see Electrical#5)
• Install kitchenette and sink with box and cold water supply and overhead cabinet(cabinets can be prefebricatrd with 4'-
6'counter top far coffee per,microwave,toaster oven,etc.).
• Sbelvhrg in baclacom. Construct two floor-to-ceiliag units approxitnately 48"wide,%."thick wood shelves
(CDX),16"deep,secured to the wall,with 12"between each shelf. Lightly sanded with a polyuretbane finish or
painted:(verify)
• Ductwork BVAC ductwork rind diflbsers installed uxtD maialftnt office area and balanced.
• 1pla0 slur:Imaill mail slot in front doorof'Prormses.
• Security bar:Install manual security bar inside backdoor ofpremises(preferece is for a bar tbat pulls down to
engage and pulls up to disengage).
• Extinguishers Famishand fnsrell code—approved fito extiaguisha;locate in as inconspicuous of a location as local
code will allow(backtoomprefared).
• Blinds,Purchase and install fabric verticalblinds(preferred)orhormutalmini-bUa&-ftoaviuylonmainsmref=t
windows(white,off-white,or shade of gray to match carpet).Also have mbuLblinds installed on the windows of any
private offices,
• Paint:Walls painted Bo 4arah Moore#961 off-white flan finish on all interior walls;ifcim and doors need to be
painted use the same color as walls with satin or eggshell finish. (2 coats)
• Moor Coverings!
I. Install uvalk-off carpet tiles in the font area ofthe otfico space to create an enayway(see the line on layout)
(Catpet the suppliedby T—=-AGF)(Color is navy)
2. Install carpet Was with 4"carpet base in office area
(Carpet We and base supplied by Tonant-AM(Color is navy and gay)
3. Install VCT,vinyl cove base,and transition strip in backroem and restrooms
(Materials conteactor-supplied in color to bleadleowdlnate wuh carpet)
Electrical and notes on following page 2
PLEASE VERIFYDIMENSIONS ON OUR FLOOR-PLAN WITH THE ACTUAL
.-OCATIONAND LET US KNOW IF THERE ARE ANY DIFM986CES
Page 1 of 3 Revised 212D2007 DPB
+ Received at: 5:26PM, 8/14/2007
Auts-14-07 04:23pm From-AGF NDOM + T-960 P-05/06 F-322
AMEIUCAN CxENERAL FINANCIAL SERVICES—FINISH SPECUICATIONS
• Electrical wotic(Tenant will provide layout for placement of coadtd;dedicated circuits,and outlets)
1. Woal6Wtioas:
One single gang box for electrical and one single gang box forvoice/data.
Voicceldata require 3/4'conduits(mum)with pull strings.
Now. Workstationsidesks have a panel that will block the ontire wall except for 6"along the bottom Install
the receptacles as close to the floor as possible/aflowabie without cutting into the 4"c upet.
2. Booth:
Duplex outlet and one sm&gang box for voice/data bath at 42"-45"above floor.
3. from Coanrer.
One dedicated 110V circuits and one single gang box for voice/data. Set for whip connection.
Voice/data requires conduits(minimarn)with pull strings.
4. Tech Center:
Two dedicated 110V circuits and one single gang box for voiceldata.One dedicated circuit should be set for
a whip connection,and the second dedicated circuit set for a duplex outlet 42145"above the fluor.
Valeeidata requites%"ceaaduits(minimum)withpull strings at 42"45"above floor.
5. Phone system(baclzroom):
Install 4'X 6'plywood board(ifncn-existnnr)at eye level for mounting phone egcupmmt.
Two gaadplex outlets(or equivalent)by plywood backboard.
3/;'conduit must be ran fkum the telephone company's box(D-Mack)on the a-mide of ffie bwlding into our
office space and terminating m the back room where the phone system win be mounted oathe wall.
The phone system and mail computer should not be located in a mechanical room or closet.
6. Main cornpmcr uaidAS400(backroom):
One dedicated I I"circuit(duplex outlet)below the plywood board for powering the train
compurrdAS400.
7. Kitchenette(baclsoom):
Dedicated quad GPI outlet(120 amp)42"high for microwave,refrigerator etc.
S. Misc.dupkx ouders:
Otuleis,in front office area and back room for vacuuming,etc.,and as needed m treat code.
9. Light swiocbes(three):
One in mar,one in fron;and one in 10 X 10 closing mom
For wxztruy purpose;one to three tights need ro rmain on when switches turned offi
10. Sign: Conduit and wire fora the electrical panel m the sigaband with one junctioabox mounted behind the
sign fleld.Timers will not be necessary other tbau anon exception basis.
11. NO POWER POLES OR EXPOSED CONDUITS WITHOUT PRIOR APPROVAL
12_ Phone and voicodam cable only will be installed by an AGF nationally contracted vendor.
13. Lighting:Cbeck the light bulbs to make sure all arc:working,and if no;install new tubes/bulbs.Also,
make sure light diffusers are in good condition.Clean or replace as necessary.
14. Furniture IastaMon: The electrician Is needed dining installation of furniture to connect the whip that
attaches our front counter and teem center lathe wall outlets.(If this office Is relocating from another
local site,the electrician will need to go to the old location we are moving from to disconnect,and return
to the now location to reconnect,untm otherwise instructed.)
NOTES:
• HVAC system—please provide an idea of age nauf/or operating condition.
• Utilities(gas,electric,and water)—please advise if service not activated.
• All systems—electrical,lighting,plumbing,sewage facilities,HVAC,and sprinkler—are to be in good
working ordta. Please advise ofany apparent defects.
• Upon completion of the job and flooring installation,the office Haut be vaatumed,all windows cleaned inside and
outside,and the restroom(s)and window sills wiped down_All construction debris musr be disposed ofwiththe
exception of 1-2 paint cans that canremafa far much-up wady_
• Please price quote for scaled architectural prints if needed above and beyond our standard layout to gain our
permits.(If scaled prints are necessary,we need the invoice to you for this service in order to reimburse your
company for the service_)
• A walkthroueh most be scheduled and completed with the office's Mstrict MiWger or Branch Manager
prior to submission of final reauest for Payment.Punch list items most be resolved for the final payment to
be released.
PLEASE VERIFYDIMENSIONS ON OUR FLOORPLAN WITH THE ACTUAL
LOCATTIONAND LET US IOVOW IF THERE ARE ANYDIFFLRENCES.
Location
Contractor:
Date Sent:
Page 2 of 3 Revised 212012007 APB
- Received at: 5:26PM, 8/14/2007
Au¢-14-07 04:24vm From-AGF HARTS + T-999 P.06/06 F-322
BID FOR
AMEWCAN GENERAL FINANCIAL SERVICES
Location:
Contractor:
Comments
Demo: $
HVAC: $
Plumbing: $
Carpentry--
Walls: $
Doors/Windows: $
Shelving: $
Kitchenette: $
Ceiling. $
Painting: $
Floor covering—
vinyl( tpnMeea): $
All install labor: $
Electric:
Lighting $
Outlets/nms/etc. $
Mail slot: S
Blinds: $
Cleanup: $
Permits: $
Plans: S
Fire protection: $
Mist: S
Misc: $
Misc• $
Mise: $
Total: $
Additional information/Comments:
Page 3 of3 Revised2/20/2007 OPB
Commercial Final Report Inspection n
� P
Office No.: (518) 761-8256 Date Inspectio uest ei d:
Queensbury Building&Code Enforcement Arrive: Z, am/ m epart: a'11 M
742 Bay Road, Queensbury,NY 12804 Inspector's I 'itia .
NAME: c
LOCATION: DATE: j
COMMENTS:
Y N NA
Chimney/"B"Vent/Direct Vent Location
Plumbing Vent Through Roof 6"/Roof Complete
Exterior Finish/Grade Complete 6"in 10' or Equivalent
Interior/Exterior Guardrails 42 in. Platform/Decks
Interior/Exterior Ballisters 4 in. Spacing Platform/Decks
Stair Handrail 34 in.—38 in./Step Risers 7"/Treads 11"
Vestibules For Exit doors>3000 s . ft.
All Doors 36 in. w/Lever Handles/Panic Hardware,if required
Exits At Grade Or Platform 36 (w)x 44"(1)/Cano or Equiv.
Gas Valve Shut-off Exposed&Regulator 18" Above Grade,
Floor Bathroom Watertight/Other Floors Oka
Relief Valve,Heat Trap/Water Temp.110 Degrees Maximum
Boiler/Furnace Enclosure 1 hr. or Fire Extinguishing System;
Fresh Air Supply for Occupancy/Ventilation Combustion
Low Water Shut Off For Boilers
Gas Furnace Shut Off Within 30 ft. or Within Line Of Site
Oil Furnace Shut Off at Entrance to Furnace Area
Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 '/z doors
> 10%> 1000 s .ft.
3/a Hour Corridor Doors&Closers
Firewalls/Fire Separation,2 Hour, 3 Hour Complete/Fire
Dampers/Fire Doors
Ceiling Fire Stopping,3,000 s . ft.Wood Frame
Attic Access 30"x 20"x 30"(h),Crawl Space Access 18"x 24"
Smoke Vents Or Fan,if required
Elevator Operation and Si a e/Shaft Sealed AA l
Handicapped Bathroom Grab Bars/Sinks/Toilets \
Handicapped Bath/Parking Lot Si na e
Public Toilet Room Handicapped Accessible ` �
Handicapped Service Counters, 34 in., Checkout 36" 0
Handicapped Ramp/Handrails Continuous/12 in.Beyond[Both sides] J
Active Listening System and Si na a Assembly Space
Final Electrical
Site Plan/Variance required
Final Survey,New Structure/Flood Plain certification,if req.
As-built Septic System Layout Required or On File
Building Number or Tenant Address on Building or Driveway
Water Fountain or Cooler /
Building Access All Sides by 20' /Driveable Surface 20'wide /
Okay To Issue Temp. or Permanent C/O
Okay To Issue C/C
L:\Building&Codes Forms\Building&Codes\Inspection Forms\Commercial Final Inspection Report.doc
I.
f
r4
I•
Inspection for Permit t0 Occupy
Fire Marshal's Office Request Rec'd ° Permit No. �
Town of Queensbury
742 Bay Road
Queensbury,NY 12804 Scheduled Inspection Date: 1 Al2 Time: J
Phone: (518)761-8206 Business Na'rne:
Fax: (518) 745-4437 Location:
{
Type of Ins ecfion N/A Yes: No
EXITS:
Exit Access COMMENTS
Exit Enclosure
Exit Discharge
AISLES:
Main Aisle Width
Secondary Aisle Width
EXIT SIGNAGE
Sign—normal
Sign-battery
EVAC signs in rooms
TRUSS ID SIGNAGE
EMERGENCY LIGHTING
FIRE EXTINGUISHER:
Hun
Inspection of extin uisher
i
FIRE ALARM SYSTEM
Fan Shutdown
Fire Sprinkler System
Fire Suppression—kitchen
Fire Suppression—.Gas Islan
Generator
Hood Installation
Elevator
Interior Finishes
Storage
Compressed Gas
Clearance to Sprinklers
Clearance to Electrical
Electric Wiring Enclosed/Labeled
Combustible Waste
Vehicle impact Protection
Knox Box 1 L1i 2�`Cll12TiL r2
F.D.Si na e-UtilityRooms
No Smoking Signs
Maximum Occupancy Sin ,mid
EmeMency Evacuation Plan
Approved (If no other approvals apply;the B&C Office will issue the Certificate of Occupancy)
o Denied / call for Recheck
Inspe, ed By:
L:\FireMarshal\New Folder\permitto occupyform.doc
V0
Inspection for Permit to Occupy
Fire Marshals Office Request Rec'd Permit No. ® / v 6l�
Town of Queensbury
742 Bay Road -rime: i
Queensbury,NY 12804 Scheduled Inspection Date:
Phone: (518)761-8206 Business Name:
Fax: (518) 745-4437 Location: 62M
Type of Inspection N/A Yes No
EXITS:
Exit Access COMMENTS
Exit Enclosure
Exit Dischar e AC
LID
AISLES: �`�Ur�.rv � Ct
Main Aisle Width
Secondar Aisle Width
EXIT SIGNAGE
Sign—normal
Sign-battery
EVAC signs in rooms
TRUSS ID SIGNAGE x
EMERGENCY LIGHTING
FIRE EXTINGUISHER: _
Hung
Inspection of extinguisher S �11,--��\ �
FIRE ALARM SYSTEM
Fan Shutdown
Fire Sprinkler System
Fire Su ression—kitchen
Fire Suppression—Gas Islan
Generator
Hood Installation
Elevator 16
Interior Finishes
Stora e
Compressed Gas
Clearance to Sprinklers
Clearance to Electrical
Electric Wiring Enclosed/Labeled
Combustible Waste
Vehicle impact Protection
Knox Box
F.D.Si na e—Utility Rooms
No Smoking Signs
Maximum Occupancy Sign,
Emergency Evacuation Plan
Approved (If no other approvals apply,the B&C Office will i e e C rtificate of Occupancy)
Denied / call for Recheck
r
Inspected By:
L:\HreMarshal\New Folder\permitto occupyform.doc
Commercial Final Inspection Report
Office No.: (518) 761-8256 Date Inspection re u t rec if
Queensbury Building&Code Enforcement Arrive: a rt:
742 Bay Road, Queensbury,NY 12804 Inspector s Initia sNAME: ME 1Cel) CE,Ji: L x AA)U PERMIT : [ZLOCATION: (` )R6ER PLAzA DATE: / [ 0 7
COMMENTS:
I
i YY N NA
Chimney/"B"Vent/Direct Vent Location
Plumbing Vent Through Roof 6"/.Roof Complete
Exterior Finish/Grade Complete 6"in 10' or Equivalent
Interior/Exterior Guardrails 42 in. Platform/Decks
Interior/Exterior Ballisters 4 in. Spacing Platform/Decks
Stair Handrail 34 in.—38 in./Step Risers 7"/Treads 11" 11
Vestibules For Exit doors>3000 sq. ft.
All Doors 36 in.w[Lever Handles/Panic Hardware,if required
Exits At Grade Or Platform 36 (w)x 44"(1)/Canopy or Equiv.
Gas Valve Shut-off Exposed&RP lator 18" Above Grade"
Floor Bathroom Waterti s Oka
Relief Valve,Heat Trap Water Temp. 110 Degrees Maximum
Boiler/Furnace Enclosure 1 hr. or Fire Extinguishing System,
Fresh Air Supply for Occupancy/Ventilation Combustion
Low Water Shut Off For Boilers
Gas Furnace Shut Off Within 30 ft. or Within Line Of Site
Oil Furnace Shut Off at Entrance to Furnace Area
Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 %Z doors
> 10%> 1000 s .ft.
3/4 Hour Corridor Doors&Closers 1
Firewalls/Fire Separation,2 Hour, 3 Hour Complete/Fire
Dampers/Fire Doors
Ceiling Fire Stopping, 3,000 s . ft.Wood Frame
Attic Access 30"x 20"x 30"(h),Crawl Space Access 18"x 24"
Smoke Vents Or Fan, if required J
Elevator Operation and Si a e/Shaft Sealed 1
Handicapped Bathroom Grab Bars/Sinks/Toilets
Handicapped Bath/Parking Lot Si na e
Public Toilet Room Handicapped Accessible
Handicapped Service Counters, 34 in., Checkout 36"
Handicapped Ramp/Handrails Continuous/12 in.Beyond [Both sides]
Active Listening System and Signage Assembly Space
Final Electrical
Site Plan/Variance required
Final Survey,New Structure/Flood Plain certification,if re` .
As-built Septic System La out Required or On File
Building Number or Tenant Address on Building or Driveway,
Water Fountain or Cooler
Building Access All Sides by 20' /Driveable Surface 20'wide
Okay To Issue Temp. or Permanent C/O
Okay To Issue C/C
L:\Building&Codes Forms\Building&Codes\Inspection Forms\Commercial Final Inspection Report.doc
Commercial.Final Inspection Report
Office No: (518) 761-8256 Date In ectio .re ce ed-
Queensbury Building&Code Enforcement Arrive: ��, a ,� Depart: ��a�
742 Bay Road, Queensbury,NY 12804 Inspector Initials.
NAME: - i�?f PERM ,
LOCATION: / )n s�{r DATE
COMMENTS:
Y N NA
Chimney/"B"Vent/Direct Vent Location
Plumbing Vent Through Roof 6"/Roof Complete
Exterior Finish/Grade Complete 6"in 10' or Equivalent
Interior/Exterior Guardrails 42 in. Platform/Decks _
Interior/Exterior Ballisters 4 in. Spacing Platform/Decks
Stair Handrail 34 in.—38 in. /Step Risers 7"/Treads 11"
Vestibules For Exit doors>3000 s . ft. <
All Doors 36 in.w/Lever Dandles/Panic Hardware,if required
Exits At Grade Or Platform 36 (w)x 44"(1)/Canopy or Equiv.
Gas Valve Shut-off Exposed&Regulator 18" Above Grade
Floor Bathroom Watertight/Other Floors Okay V
Relief Valve,Heat Trap/Water Temp. 110 Degrees Maximum
Boiler/Furnace Enclosure 1 hr. or Fire Extinguishing System
Fresh Air Supply for Occupancy/Ventilation Combustion
Low Water Shut Off For Boilers
Gas Furnace Shut Off Within 30 ft. or Within Line Of Site
Oil Furnace Shut Off at Entrance to Furnace Area
Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 %.doors
> 10%> 1000 s . ft.
3/a Hour Corridor Doors&Closers
Firewalls/Fire Separation,2 Hour, 3 Hour Complete/Fire
Dampers/Fire Doors
Ceiling Fire Stopping,3,000 s . ft.Wood Frame
Attic Access 30"x 20"x 30"(h),Crawl Space Access 18"x 24"
Smoke Vents Or Fan, if required
Elevator Operation and Si a e/Shaft Sealed
Handicapped Bathroom Grab Bars/Sinks/Toilets
Handicapped Bath/Parking Lot Si na e
Public Toilet Room Handicapped Accessible
Handicapped Service Counters, 34 in.,Checkout 36"
Handicapped Ramp/Handrails Continuous/12 in.Beyond [Both sides]
Active Listening System and Signage Assembly Space
Final Electrical
Site Plan/Variance required
Final Survey,New Structure/Flood Plain certification,if req.
As-built Septic System La out Required or On File
Building Number or Tenant Address on Building or Driveway
Water Fountain or Cooler
Building Access All Sides by 20' /Driveable Surface 20'wide
Okay To Issue Temp. or Permanent C/O
Okay To Issue C/C
L:\Building&Codes Forms\Building&Codes\Inspection Forms\Commercial Final Inspection Report.doc
.. _ q,;
i �
}1�
\' - � - -
,,
MIDDLE DEPARTMENT INSPECTION AGENCY, INC.
Ve that the electrical wiring to the electrical equipment listed below has been examined and is approved as
being in accord with the National Electrical Code, applicable governmental, utility and Agency rules in effect on the date
noted below and is issued subject to the following conditions.
Owner: America Finance Date: 11/19/2007
Occupant: Unknown Location:
Quaker Plaza
Occupancy: Non-Residential Queensbury, Warren Co. NY
Applicant
C &G ElectricDEP
840 Eastern Avenue ,��
Schenectady, NY 12348'
Raymond A. Nouak
No.
- - - - - 140719165.1,99E .> �. _:, —,
Equipment:
8-Switches p ,23 -Rece tacles 24 Fixtur'es� =This certificate applies to the electrical wiring to the electrical equipment listed immediately null and void.'This certificate applies only to the use,occupancy and
above and the installation inspected as of the above noted date based on a visual ownership as indicated herein. Upon a'change in the use,occupancy or ownership
inspection. No'warranty is expressed or implied as to the mechanical safety,effi- of the property indicated above,this certificate shall be immediately null and void.
ciency or fitness of the equipment for any particular purpose. This certificate shall In the event that this certificate becomes invalid based upon the above conditions,
be valid for a period of one year from the above noted date. Should the electrical this certificate may be revalidated upon reinspection by Middle Department
system to which this certificate applies be altered in any way,including but not limit- Inspection Agency, Inc. An application for inspection must be submitted to Middle
ed to,the introduction of additional electrical equipment and/or the replacement of Department Inspection Agency, Inc, to initiate the inspection and revalidation
any of the components installed as of the above noted date,this certificate shall be I process. A fee will be charged for this sarvir
vvAk--)
Framing/ Firestopping Inspection Re ort
Office No. (518) 761-8256 Date inspection req e ceive
Queensbury Building&Code Enforcement Arriv,,-: :�3O a D art: am/
742 Bay Road, Queensbury,NY 12804 Inspector's Initial
NAME: PERMIT#: o
LOCATION: INSPECT ON: — —
TYPE OF STRUCTURE: '' t-A
Y N N/A
Framing COMMENTS
Attic Access 22"x 30"minimum
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 %z w 16 gauge 8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
Ice and water shield 24 inches from wall
Fire separation 1, 2, 3 hour
Fire wall 2, 3,4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side %z inch or 5/8 inch Type X
Garage side 518 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
Rough Plumbing / Insulation Inspection Report
Office No. (518) 761-8256 Date Inspection request received: l'
Queensbury Building &Code Enforcement Arrive: am/q a art: am/pm
742 Bay Road, Queensbury, NY 12804 Inspect is Initials:
�
NAME: A�k�f") ����1C c_ ;- PERMIT #: ta-
LOCATION: aU, r< G� INSPECT ON: /a- /�d
TYPE OF STRUCTURE:
Y N N/A-
Rough Plumbin - Nail Plates
Plumbing Vent Vents in Place
1 1/2 inch minimum Drain Size
Washing Machine Drain 2 inch minimum
leanout every 100 feet , change of direction
Press est
Drrd
ye
Air
5 P ft. above highest connection for 15 minutes
Press est
Water Supply Piping
Air/ Head
50 P.S.1 for 15 minutes
Insulation Residential Check Commercial Check
Proper Vent Attic Vent
Duct/ Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace i
Duct work sealed properly No duct tape
COMMENTS:
LAPam Whiting\Building&CodeAInspection Forms\Rough Plumbing Insulation Report.revised Nov 0 2003.doo Revised February 15,2005
Framing / Firestopping Inspection Report i
Office No. (518)761-8256 Date Insge 4o equest received: JO l( U�
Queensbury Building&Code Enforcement Arrive: 1 . OUam/ D part: m/pm
742 Bay Road,Queensbury,NY 12804 Inspectof s Initials:
NAME: / -r -'�.(�ie� ��� `--PPRMIT#:
LOCATION: INSPECT ON: `7
TYPE OF STRUCTURE:
Y N N/A COMMENTS
Framing 1
J
Attic Access 22"x 30"minimum
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly .i
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Headroom 6 ft. 8 in. I
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 '/z(w) 16 gauge(8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
Ice and water shield 24 inches from wall
Fire separation 1,2, 3 hour
Fire wall 2, 3,4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side %inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
Rough Plumbing / Ins.ula. Lion Inspection Report
Office No. (518) 761-8256 Date Inspection request received: t u�
Queensbury Building & Code Enforcement Arrive: am/ iDepart: am/pm
742 Bay Road, Queensbury, NY 12804 Inspector's Initials:C�
NAME: >°�Lsi.�.6- CPERMIT #: ��
LOCATION: L 1 INSPECT ON: 1g)
TYPE OF STRUCTURE: c--
Y N N/A
ou h;_Pfurvt�in/SNail Plates
Plum in ent/ Vents in Place
1 1/2 inch minimum Drain Size
as ing Machine Drain 2 inch minimum
eanout every,100 feet change of direction
C:APressurTest'
Drain / Vent
Air/ Head
5 P.S.I. or 10 ft. above highest connection for 15 minutes
ter Supply Piping
it Head
P.S.I for 15 minutes ;� �C C' K/ 1 a
Insulation Residential Check/ Commercial Check '
Proper Vent Attic Vent
Duct/ Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct work sealed properly / No duct tape
1-9Uc
LAPam Whiting\Building&Codes\Inspection Formsaough Plumbing Insulation Report.revised Nov 17 2003.doe Revised February 15,2005
. . ... _ _. .� - �. - �...,�_a •-� .,.�,. �-„�.s-r.-.��-.ter.--•- -----
��
'1 .
,. �
♦ �'
�- .• '
,�
1 �M�/.
� � �
S ..