Loading...
CC-0729-2021 Office Use Only � r ` ADDITION/ALTERATION PERMIT Permit#: CC —0 :- 202 APPLICATION Permit Fee:$ �5 Town of Qae ne sbury 742 Bay Road,Queensbury, NY 12804 Invoice #: �v P:518-761-8256 www.queensbury.net Flood Zone? Y N eyiewed Project LocationXCarey Road Bldg. 2 Basement Tax Map ID #: 309.13-2-31.2 Subdivisior I E. C E O V E OCT 0 4 2021 PROJECT INFORMATION: TOWN OF QUEENSBURY BUILDING& CODES TYPE: Residential x Commercial, Proposed Use: Single-Family Two-Family Multi-Family (#ofunits_ Townhouse Business Office Retail Industrial/Warehouse Garage (#of cars ) x Other(describe)—Health Care Facility Expansion ADDITION SQUARE FOOTAGE: ALTERATION SQUARE FOOTAGE: 1st floor: 1st 2ndfloor: floor: 31d floor: 2ndfloor: Basement (habitable 31d floor: space): Basement (habitable space): Total sq ft: 1,300 Total sq ft: Scope of work to be done: Renovation of approximately 1,300 s.f. of existing storage areas within the basement level of HHHN Building#2, located at the 161 Carey Road.The project's program is inclusive of examination and office space to be added to the existing Saratoga Hospital Pulmonary Clinic. Addition/Alteration Application Revised January2021 ADDITIONAL PROJECT INFORMATION: 1. Estimated Cost of Construction: $260,000.00 2. Source of Heat(circle one): x Gas Oil Propane Solar Other Fireplaces/inserts need a separate Fuel Burning Appliances & Chimney Application 3. Are there any structures not shown on the plot plan? YES x NO Explain: 4. Are there any easements on the property? YES x NO SITE INFORMATION: • Is this a corner lot? YES NO • Will the grade be changed as a result of the construction? YES NO • What is the water source? x PUBLIC PRIVATE WELL • What type of wastewater system is on the parcel? x SEWER PRIVATE SEPTIC DEC RATIOM: I. 1 acknowledge that no construction shall be commenced prior to the issuance of a valid permit and will be completed within a 12 month period.Any changes to the approved plans priorto/during construction will require the submittal of amended plans, additional reviews and re-approval. 2. If,foranyreason,the building permit application iswithdrawn,30%ofthefee is retained bytheTownof Queensbury. After 1 year from the initial application date, 100%of the fee is retained. 3. If the work is not completed by the 1 year expiration date the permit may be renewed, subject to fees and department approval. 4. 1 certifythatthe application,plans and supporting materials areatrueand a complete statement and/or description of the work proposed,thatall workwill be performed in accordance withthe NYS Building Codes,local building laws and ordinances, and in conformance with local zoning regulations. 5. 1 acknowledge that prior to occupying the facilities proposed I, or my agents, will obtain a certificate of occupancy. 6. 1 also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance ofa certificate of occupancy. I have read and agree to the above: PRINT NAME: SIGNATURE: DATE: 100/1 Addition/Alteration Application Revised January2021 CONTACT INFORMATION: PLEASE PRINT LEGIBLY OR TYPE, PLEASE INCLUDE AN EMAIL • Applicant: Name(s): Hudson Headwaters Health Network Address, C/S/Z: 9 Carey Road Queensburv, NY 12804 Cell Phone: (518) 857-3408 Land Line: � ) Email:-dvalentini@hhhn.org. Primary Owner(s): Name(s): Hudson Headwaters Health Network Mailing Address, C/S/Z: 9 Carey Road Queensburv, NY 12804 Cell Phone: (518) 857-3408 Land Line: Email: dvalentini@hhhn.org C Check if all work will be performed by property owner on_yl • Contractor(s): (List all additional contractors on the back of thisform) Contact Name(s): AOW Construction Contractor Trade: General Contractor Mailing Address, C/S/Z: 30 Essex St Albany, NY 12206 Cell Phone:) Land Line: (518) 482-3400 Email: apelfrev@aowconstruction.com **Workers' Comp documentation must be submitted with this alplication** • Arch itect(s)/Engi nee r(s): Business Name: The Architectural Collaborative Contact Name(s): Jon P r i m e a u Mailing Address, C/S/Z: 33 Church Street Saratoga Springs, NY 12866 Cell Phone:) Land Line: (518) 796-6236 Email: ion@the archcollaborative.com Contact Person for Compliance in regards to this project: Jon Primeau Cell Phone:) Land Line: Email: ion@the archcollaborative.com Addition/Alteration Application Revised January2021 • Contractor(s): Workers' Comp documentation must be submitted with this application Contractor Name(s): Absolute Fire Protection LLC Contractor Trade: Fire Suppression Mailing Address, C/S/Z: 1182 US Route 9W (PO Box 10) Selkirk, NY 12158 Cell Phone: Land Line: (518) 767-3700 Email: • Contractor(s): Workers' Comp documentation must be submitted with this application Contractor Name(s): Tri Valley Plumbing & Heating, Inc Contractor Trade: Plumber Mailing Address, C/S/Z: 2617 Hamburg St. Schenectady, NY 12303 Cell Phone: Land Line: (518) 355-8039 Email: • Contractor(s): Workers' Comp documentation must be submitted with this application Contractor Name(s): JDJ Comfort Systems Contractor Trade: HVAC Mailing Address, C/S/Z: 44 Brickyard Rd. Mechanicville, NY 12118 Cell Phone: Land Line: (518) 857-6131 Email: • Contractor(s): Workers' Comp documentation must be submitted with this application Contractor Name(s): Prediletto Electric Contractor Trade: Electrician Mailing Address, C/S/Z: 56 Clifton Country Rd. Suite 108 Clifton Park, NY 12065 Cell Phone: Land Line: (518) 371-2511 • Contractor(s): Workers' Comp documentation must be submitted with this application Contractor Name(s): Jimco Painting Contractor Trade: Painter Mailing Address, C/S/Z: 14 Cliff View Lane Voorheesville, NY 12186 Cell Phone: Land Line: (518) 368-2932 Email: Addition/Alteration Application Revised January2021 FIRE MARSHAL'S OFFICE Town of Queensbury 742 Bay Road, Queensbury, NY 12804 "Home of Natural Beauty ... A Good Place to Live " LAN RE iE ` HHHN / Saratoga Hospital 151 Carey Road B-100 CC-0729-2021 10/7/21 I have reviewed the submitted drawings for the above project; and offer the following comments: 1) Verify Fire extinguisher Inspection & locations per plan. 2) Locks / latches shall comply with 2020 NYSFC. 3) Exit-emergency light plan appears adequate. Fire Marshal to witness a function test prior to CO. 4) Verify Knox Box keys. 5) Verify aisles & storage. 6) Provide NFPA 72 letter for fire alarm modifications. 7) Provide NFPA 13 letter for sprinkler modifications. 8) Carbon Monoxide detection required. 4n, Deputy Fire Marshal Gary K. Stillman 742 Bay Road Queensbury NY 12804 518 761 8205 garys@queensbury.net Fire Marshal 's Office • Phone: 518-761-8206 Fax: 518-745-4437 Crenuirslual@queensbuni.net • WWW.queensbun .net COMcheck Software Version 4.1.5.3 Interior Lighting Compliance Certificate OF Epy Project Information COS° Energy Code: 2018 IECC `�� z Project Title: 2 Project Type: New Construction 07788-rA � ssfoNP�' Construction Site: Owner/Agent: Designer/Contractor: Additional Efficiency Package(s) REVIEWED FOR Credits: 1.0 Required 1.0 Proposed Reduced Lighting Power,1.0 credit ENERGY CODE COMPLIANCE Allowed Interior Lighting Power A B C D Area Category Floor Area Allowed Allowed Watts (ft2) Watts/ft2 (B X C) 1-Health Care-Clinic 1250 0.74 922 Total Allowed Watts= 923 Proposed Interior Lighting Power A B C D E Fixture ID: Description/Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D) Fixture Fixtures Watt. 1-Health Care-Clinic LED 1:Al:Other: 1 10 33 331 LED 2:131:Other: 1 7 38 269 LED 3:Cl:Other: 1 6 10 62 LED 4:D1:Other: 1 5 8 40 Total Proposed Watts= 702 Interior Lighting PASSES: Design better than code Interior Lighting Compliance Statement Compliance Statement. The proposed interior lighting design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application.The proposed interior lighting systems have been designed to meet the 2018 IECC requirements in COMcheck Version 4.1.5.3 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name-Title Signature Date Project Title: Report date: 10/11/21 Data filename: \\albafilel\alba_Projects\2021\21-3100\213184\Design\Deslnfo\ComCheck\213184_Comcheck.c Page 1 of 12 COMcheck Software Version 4.1.5.3 Mechanical Compliance Certificate OF e Project Information Energy Code: 2018 IECC z Project Title: 2 Location: Glens Falls, New York Climate Zone: 6a 'sjpNP+ Project Type: New Construction Construction Site: Owner/Agent: Designer/Contractor: Additional Efficiency Package(s) Credits: 1.0 Required 1.0 Proposed Reduced Lighting Power,1.0 credit Mechanical Systems List Quantity System Type&Description 1 GF-2(Single Zone): Heating:1 each-Duct Furnace,Gas,Capacity=38 kBtu/h Proposed Efficiency=95.00%Ec,Required Efficiency: 80.00%Ec Cooling:1 each-Split System,Capacity=25 kBtu/h,Air-Cooled Condenser,No Economizer,Economizer exception:None Proposed Efficiency=14.00 SEER,Required Efficiency: 13.00 SEER Fan System: FAN SYSTEM 1—Compliance(Motor nameplate HP method):Passes Fans: FAN 1 Supply,Constant Volume,984 CFM,0.5 motor nameplate hp,0.0 fan efficiency grade Mechanical Compliance Statement Compliance Statement. The proposed mechanical design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application.The proposed mechanical systems have been designed to meet the 2018 IECC requirements in COMcheck Version 4.1.5.3 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name-Title Signature Date Project Title: Report date: 10/11/21 Data filename: \\albafilel\alba_Projects\2021\21-3100\213184\Design\Deslnfo\ComCheck\213184_Comcheck.c Page 2 of 12 COMcheck Software Version 4.1.5.3 Inspection- Checklist Energy Code: 2018 IECC Requirements: 100.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement,the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed.Where compliance is itemized in a separate table, a reference to that table is provided. Section # Plan Review Complies? Comments/Assumptions & Req.ID C103.2 ;,Plans, specifications, and/or ;❑Complies ;Requirement will be met. [PR2]1 calculations provide all information :❑Does Not ;with which compliance can be ; ;Location on plans/spec: Drawings determined for the mechanical ❑Not Observable systems and equipment and ,❑Not Applicable ;document where exceptions to the standard are claimed. Load calculations per acceptable engineering standards and ; handbooks. I C103.2 ;,Plans,specifications, and/or ;❑Complies ;Requirement will be met. [PR4]1 :calculations provide all information :❑Does Not ;with which compliance can be determined for the interior lighting ;❑Not Observable and electrical systems and equipment :❑Not Applicable ;and document where exceptions to ;the standard are claimed. Information provided should include interior I lighting power calculations,wattage of; ; bulbs and ballasts,transformers and control devices. C406 ;Plans,specifications, and/or ;❑Complies ;Requirement will be met. [PR9]1 calculations provide all information :❑Does Not with which compliance can be i determined for the additional energy ![]Not Observable efficiency package options. ;❑Not Applicable ; Additional Comments/Assumptions: 11 High Impact(Tier 1) 1 2 1 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Report date: 10/11/21 Data filename: \\albafilel\alba Projects\2021\21-3100\213184\Design\Deslnfo\ComCheck\213184_Comcheck.c Page 3 of 12 Section # Footing/Foundation Inspection Complies? Comments/Assumptions & Req.ID C403.12.2;Snow/ice melting system and freeze ;[ Complies ;Exception: Requirement does not apply. i protection systems have sensors and :❑Does Not C403.12.3;controls configured to limit service for ;❑Not Observable [F09]3 ;pavement temperature and outdoor ; #temperature.future connection to ;❑Not Applicable controls. Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3, Low Impact(Tier 3) Project Title: Report date: 10/11/21 Data filename: \\albafilel\alba_Projects\2021\21-3100\213184\Design\Deslnfo\ComCheck\213184 Comcheck.c Page 4 of 12 Section # Plumbing Rough-in Inspection Complies? Comments/Assumptions & Req.ID C404.5, ;Heated water supply piping conforms ;❑Complies 1 Exception: Requirement does not apply. C404.5.1, to pipe length and volume :❑Does Not C404.5.2 i requirements. Refer to section details. [PL6]3 ; :❑Not Observable i :❑Not Applicable C404.6.3 Pumps that circulate water between a ;❑Complies ;Exception: Requirement does not apply. [PL7]3 j heater and storage tank have controls :❑Does Not that limit operation from startup to I 1❑Not Observable<= 5 minutes after end of heating cycle. ;❑Not Applicable C404.7 !Demand recirculation water systems ;❑Complies ;Exception: Requirement does not apply. [PL8]3 have controls that start the pump ;❑Does Not i upon receiving a signal from the i action of a user of a fixture or 1,❑Not Observable 3 appliance and limits the temperature ❑Not Applicable of the water entering the cold-water ; piping to 104°F. 1 Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Report date: 10/11/21 Data filename: \\albafilel\alba_Projects\2021\21-3100\213184\Design\Deslnfo\ComCheck\213184 Comcheck.c Page 5 of 12 Section # Mechanical Rough-In Inspection Complies? Comments/Assumptions & Req.ID C402.2.6 Thermally ineffective panel surfaces of;❑Complies Requirement will be met. [ME41]3 sensible heating panels have :❑Does Not insulation >= R-3.5. :[]Not Observable;Location on plans/spec:Schedule ;❑Not Applicable C403.11.3;HVAC piping insulation insulated in ;❑Complies ;Requirement will be met. [ME61]2 ;accordance with Table C403.11.3. PDoes Not ;Insulation exposed to weather is ;❑Not Observable; on plans/spec: Drawings protected from damage and is , !provided with shielding from solar .❑Not Applicable radiation. C403.8.4 !Motors for fans that are not less than ;❑Complies !Requirement will be met. [ME142]2 �1/12 hp and less than 1 hp are ' ;❑Does Not electronically commutated motors or 1 ;Location on plans/spec: Schedules ',have a minimum motor efficiency of ;❑Not Observable 1 70 percent.These motors have the ;❑Not Applicable means to adjust motor speed. ; C403.8.5 'Each DX cooling system >65 kBtu ;❑Complies ;Requirement will be met. [ME143]2 and chiller water/evaporative cooling E❑Does Not system with fans> 1/4 hp are ;❑Not Observable;Location on plans/spec: Schedules ,designed to vary the indoor fan airflow, as a function of load and comply with �❑Not Applicable ;detailed requirements of this section. ; C403.12.1!,Systems that heat outside the building;❑Complies ;Exception: Requirement does not apply. [ME71]2 envelope are radiant heat systems ;❑Does Not ;controlled by an occupancy sensing ; device or timer switch. ❑Not Observable ;❑Not Applicable C403.2.3 ;HVAC equipment efficiency verified. ;❑Complies ;See the Mechanical systems list for values. [ME55]2 ;❑Does Not I.❑Not Observable; ;❑Not Applicable C403.2.2 Natural or mechanical ventilation is ;❑Complies :Requirement will be met. [ME59]1 :provided in accordance with ;❑Does Not International Mechanical Code :Location on plans/spec: Drawings ;Chapter 4. Mechanical ventilation has ![]Not Observable capability to reduce outdoor air supply!❑Not Applicable ;to minimum per IMC Chapter 4. ; C403.7.1 {Demand control ventilation provided ;,[]Complies ;Exception: Requirement does not apply. [ME59]1 :for spaces>500 ft2 and >25 ;❑Does Not people/1000 ft2 occupant density and ; ; served by systems with air side []Not Observable economizer, auto modulating outside ;❑Not Applicable ; air damper control,or design airflow >3,000 cfm. C403.7.2 'Enclosed parking garage ventilation ;❑Complies ;Exception: Requirement does not apply. [ME115]3 has automatic contaminant detection :❑Does Not 3 and capacity to stage or modulate fans to 50%or less of design capacity.;❑Not Observable ;❑Not Applicable C403.7.6 (HVAC systems serving guestrooms in ;❑Complies ;Exception: Requirement does not apply. [ME141]3 Group R-1 buildings with >50 ;❑Does Not guestrooms: Each guestroom is provided with controls that ;❑Not Observable; automatically manage temperature ;❑Not Applicable setpoint and ventilation (see sections C403.7.6.1 and C403.7.6.2). ; C403.7.4 ;Exhaust air energy recovery on ;❑Complies ;Requirement will be met. [ME57]1 systems meeting Table C403.7.4(1) T❑Does Not ;and C403.7.4(2). ;❑Not Observable; ;❑Not Applicable 1 I High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Report date: 10/11/21 Data filename: \\albafilel\alba_Projects\2021\21-3100\213184\Design\Deslnfo\ComCheck\213184_Comcheck.c Page 6 of 12 Section # Mechanical Rough-In Inspection Complies? Comments/Assumptions & Req.ID C403.7.5 ;Kitchen exhaust systems comply with ;❑Complies ;Exception: Requirement does not apply. [ME116]3 !replacement air and conditioned E❑Does Not }supply air limitations, and satisfy hood ❑Not Observable rating requirements and maximum ;exhaust rate criteria. ;❑Not Applicable C403.11.1HVAC ducts and plenums insulated in :[]Complies ;Requirement will be met. accordance with C403.11.1 and ;❑Does Not C403.11.2;constructed in accordance with ❑Not Observable!Location on plans/spec:Specs [ME60]2 ;C403.11.2,verification may need to ; occur during Foundation Inspection. ❑Not Applicable C403.4.1. ;Heating for vestibules and air curtains ;❑Complies ;Exception: Requirement does not apply. 4 with integral heating include ;❑Does Not [ME63]2 automatic controls that shut off the heating system when outdoor air [--]Not Observable temperatures>45F.Vestibule ;❑Not Applicable heating and cooling systems controlled by a thermostat in the ; vestibule with heating setpoint<_ 1.60F and cooling setpoint>=80F. C403.3.3 :Hot gas bypass limited to: <=240 ;❑Complies ;Requirement will be met. [ME35]1 kBtu/h-50%>240 kBtu/h-25% :❑Does Not ❑Not Observable:Location on plans/spec:Schedule ❑Not Applicable C408.2.2. Air outlets and zone terminal devices ;❑Complies ;Requirement will be met. 1 have means for air balancing. T❑Does Not [ME53]3 Location on plans/spec: Drawings $ ,❑Not Observable ❑Not Applicable C403.5, Refrigerated display cases,walk-in ;❑Complies ;Exception: Requirement does not apply. C403.5.1, coolers.or walk-in freezers served by T❑Does Not C403.5.2 3 remote compressors and remote [ME123]3 condensers not located in a UNot Observable; r condensing unit, have fan-powered ,❑Not Applicable condensers that comply with Sections C403.5.1 and refrigeration compressor; systems that comply with C403.5.2.. Additional.Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3, Low Impact(Tier 3) Project Title: Report date: 10/11/21 Data filename: \\albafilel\alba_Projects\2021\21-3100\213184\Design\Deslnfo\ComCheck\213184_Comcheck.c Page 7 of 12 Section # Rough-In Electrical Inspection Complies? Comments/Assumptions & Reci.ID C405.2.2. ;Spaces required to have light- ;❑Complies ;Requirement will be met. 2 :reduction controls have a manual ;❑Does Not [EL22]1 ;control that allows the occupant to reduce the connected lighting load in ;❑Not Observable a reasonably uniform illumination ;❑Not Applicable pattern >=50 percent. ; C405.2.1, ;Occupancy sensors installed in ;❑Complies ;Requirement will be met. C405.2.1. classrooms/lecture/training rooms, ;,❑Does Not 1 ;conference/meeting/multipurpose [EL18]1 !rooms, copy/print rooms, :❑Not Observable lounges/breakrooms, enclosed offices, 1❑Not Applicable ;open plan office areas, restrooms, ;storage rooms, locker rooms, ; warehouse storage areas,and other ;spaces<=300 sqft that are enclosed by floor-to-ceiling height partitions. ;Reference section language C405.2.1.2 for control function in ; warehouses and section C405.2.1.3 ; :for open plan office spaces. C405.2.1. :Occupancy sensors control function in ;❑Complies ;Exception: Requirement does not apply. 2 :warehouses: In warehouses,the ! Does Not [EL19]1 :lighting in aisleways and open areas i ❑ s controlled with occupant sensors that ;❑Not Observable automatically reduce lighting power �❑Not Applicable by 50%or more when the areas are ; unoccupied.The occupant sensors control lighting in each aisleway independently and do not control ; :lighting beyond the aisleway being ; !controlled by the sensor. C405.2.1. !Occupant sensor control function in ;❑Complies ;Exception: Requirement does not apply. 3 :open plan office areas: Occupant :❑Does Not [EL20]1 ;sensor controls in open office spaces ❑Not Observable >= 300 sq.ft. have controls 1) configured so that general lighting can�❑Not Applicable be controlled separately in control ; zones with floor areas<=600 sq.ft. within the space, 2)automatically turn: off general lighting in all control zones within 20 minutes after all occupants have left the space,3) are configured so that general lighting power in each ; control zone is reduced by>=80%of. ; ;the full zone general lighting power ;within 20 minutes of all occupants ; leaving that control zone, and 4) are configured such that any daylight responsive control will activate space ; general lighting or control zone general lighting only when occupancy for the same area is detected. ; C405.2.2, ;Each area not served by occupancy ;❑Complies ;Requirement will be met. C405.2.2. :sensors(per C405.2.1)have time- :❑Does Not 1, ;switch controls and functions detailed ; C405.2.2. ;in sections C405.2.2.1 and C405.2.2.2.;❑Not Observable 2 ;❑Not Applicable [EL21]z ; 1 I High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Report date: 10/11/21 Data filename: \\albafilel\alba Projects\2021\21-3100\213184\Design\Desinfo\ComCheck\213184_Comcheck.c Page 8 of 12 Section # Rough-In Electrical Inspection Complies? Comments/Assumptions & Req.ID C405.2.3, ;Daylight zones provided with ;❑Complies ;Exception: Requirement does not apply. C405.2.3. individual controls that control the PDoes Not 1, ;lights independent of general area C405.2.3. ;lighting.See code section C405.2.3 1❑Not Observable 2 Daylight-responsive controls for ;❑Not Applicable [EL23]2 ;applicable spaces,C405.2.3.1 Daylight; ;responsive control function and ; section C405.2.3.2 Sidelit zone. C405.2.4 ;Separate lighting control devices for ;❑Complies :Requirement will be met. [EL26]1 :specific uses installed per approved :❑Does Not `lighting plans. UNot Observable; ❑Not Applicable C405.2.4 ;Additional interior lighting power ;❑Complies ;Requirement will be met. [EL27]1 :allowed for special functions per the :❑Does Not ;approved lighting plans and is ;automatically controlled and ❑Not Observable; separated from general lighting. :❑Not Applicable C405.3 ;Exit signs do not exceed 5 watts per ;❑Complies ;Requirement will be met. [EL6]1 ;face. ;❑Does Not ❑Not Observable; ;❑Not Applicable C405.6 ;Low-voltage dry-type distribution ;❑Complies ;Exception: Requirement does not apply. [EL26]2 ;electric transformers meet the ;❑Does Not minimum efficiency requirements of ;Table C405.6. :, Not Observable; ;❑Not Applicable C405.7 ;,Electric motors meet the minimum . ;❑Complies ;Requirement will be met. [EL27]2 !efficiency requirements of Tables :❑Does Not C405.7(1)through C405.7(4). Efficiency verified through certification;❑Not Observable under an approved certification :❑Not Applicable program or the equipment efficiency ; ; ratings shall be provided by motor ; !manufacturer(where certification ; programs do not exist). C405.8.2, :Escalators and moving walks comply ;❑Complies ;Exception: Requirement does not apply. C405.8.2. iwith ASME A17.1/CSA B44 and have T❑Does Not 1 ;automatic controls configured to ; [EL28]2 ;reduce speed to the minimum ;❑Not Observable permitted speed in accordance with ,❑Not Applicable ;ASME A17.1/CSA B44 or applicable ; )local code when not conveying passengers. C405.9 ;Total voltage drop across the ;❑Complies ;Requirement will be met. [EL29]2 �combination of feeders and branch ;❑Does Not ;circuits <=5%. :❑Not Observable; :1--]Not Applicable Additional Comments/Assumptions: 111 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Report date: 10/11/21 Data filename: \\albafilel\alba Projects\2021\21-3100\213184\Design\Deslnfo\ComCheck\213184_Comcheck.c Page 9 of 12 Section # Final Inspection Complies? Comments/Assumptions & Req.ID C303.3, IFurnished O&M instructions for I❑Complies ;Requirement will be met. C408.2.5. ;systems and equipment to the ;❑Does Not 2 ;building owner or designated [FI17]3 representative. �❑Not Observable ;❑Not Applicable C303.3, Furnished O&M manuals for HVAC ;❑Complies ;Requirement will be met. C408.2.5. systems within 90 days of system E❑Does Not 3 acceptance. [F18]3 ;❑Not Observable; I i ❑Not Applicable C403.2.2 HVAC systems and equipment ;❑Complies !Requirement will be met. [F127]3 capacity does not exceed calculated ;❑Does Not loads. :Location on plans/spec: Schedule ;[-]Not Observable ❑Not Applicable C403.2.4, s Heating and cooling to each zone is ;[]Complies ;Requirement will be met. 1 controlled by a thermostat control. ;❑Does Not [F147]3 Minimum one humidity control device ❑Not Observable;Location on plans/spec: M1.0 per installed humidification/dehumidification �❑Not Applicable system. C403.4.1. Thermostatic controls have a 5 °F ;❑Complies ;Requirement will be met. 2 deadband. ;❑Does Not [F138]3 ;Location on plans/spec: Specs ❑Not Observable ❑Not Applicable C403.2.4. (Temperature controls have setpoint I❑Complies ;Requirement will be met. 1.3 overlap restrictions. ;❑Does Not [F120]3 ; :Location on plans/spec: Specs ❑Not Observable ❑Not Applicable C403.2.4. !Each zone equipped with setback X❑Complies !Exception: Requirement does not apply. 2 controls using automatic time clock or ❑Does Not [FI39]3 ;programmable control system. 1 ;❑Not Observable R ;❑Not Applicable C403.2.4. jAutomatic Controls: Setback to 557 I❑Complies :Requirement will be met. 2.1, (heat)and 85°F (cool); 7-day clock, 2- ;❑Does Not C403.2.4. hour occupant override, 10-hour Location on plans/spec: Specs 2.2 lbackup ;❑Not Observable; [F140]3 ;❑Not Applicable C403.2.4. I Systems include optimum start ;❑Complies ;,Exception: Requirement does not apply. 2.3 controls. ;❑Does Not [F141]3 ;❑Not Observable; ❑Not Applicable C405.4.1 i Interior installed lamp and fixture ;❑Complies ;See the Interior Lighting fixture schedule for values. [F[18]1 :lighting power is consistent with what :❑Does Not is shown on the approved lighting ; !plans, demonstrating proposed watts ;❑Not Observable are less than or equal to allowed :❑Not Applicable watts. C408.1.1 i Building operations and maintenance ;❑Complies ;Requirement will be met. [FI57]1 �documents will be provided to the I❑Does Not ;owner. Documents will cover manufacturers' information, :❑Not Observable :specifications, programming ;❑Not Applicable procedures and means of illustrating ; I to owner how building,equipment and; systems are intended to be installed, maintained, and operated. 1 I High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Report date: 10/11/21 Data filename: \\albafilel\alba_Projects\2021\21-3100\213184\Design\Deslnfo\ComCheck\213184_Comcheck.c Page 10 of 12 Section # Final Inspection Complies? Comments/Assumptions &Req.ID C408.2.1 ;Commissioning plan developed by ;❑Complies ;Requirement will be met. [FI28]1 :registered design professional or T❑Does Not approved agency. :Location on plans/spec: Specs ❑Not Observable j ;❑Not Applicable C408.2.3. ;HVAC equipment has been tested to ;❑Complies ;Requirement will be met. 1 censure proper operation. ;❑Does Not [F131]1 !Location on plans/spec: Specs ❑Not Observable ❑Not Applicable C408.2.3. ;HVAC control systems have been ;❑Complies ;Requirement will be met. 2 tested to ensure proper operation, ;❑Does Not [FI10]1 :calibration and adjustment of controls.:❑Not Observable on plans/spec: Specs ❑Not Applicable C408.2.4 ;Preliminary commissioning report ;❑Complies ;Requirement will be met. [F129]1 completed and certified by registered :❑Does Not ;design professional or approved ;Location on plans/spec:Specs agency. :❑Not Observable ;❑Not Applicable ; C408.2.5. 1 Furnished HVAC as-built drawings ;❑Complies ;Requirement will be met. 1 submitted within 90 days of system ;❑Does Not [FI7]3 acceptance. ![:]Not Observable ❑Not Applicable ; C408.2.5. Furnished as-built drawings for ;❑Complies ;Requirement will be met. 1 ;electric power systems within 90 days ;❑Does Not [FI16]3 of system acceptance. ❑Not Observable; ❑Not Applicable C408.2.5. An air and/or hydronic system ;❑Complies ;Requirement will be met. 3 balancing report is provided for HVAC �,❑Does Not [F]43]1 ;systems. I Location on plans/spec:Specs ❑Not Observable; ❑Not Applicable C408.2.5. ;Final commissioning report due to ;❑Complies ;Requirement will be met. 4 building owner within 90 days of ;❑Does Not [F130]1 receipt of certificate of occupancy. I❑Not Observable:Location on plans/spec:Specs ❑Not Applicable C408.3 ;Lighting systems have been tested to ;❑Complies :Requirement will be met. [F133]1 :ensure proper calibration,adjustment,QDoes Not I programming,and operation. ; ❑Not Observable; El Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Report date: 10/11/21 Data filename: \\albafilel\alba_Projects\2021\21-3100\213184\Design\Deslnfo\ComCheck\213184_Comcheck.c Page 11 of 12 Project Title: Report date: 10/11/21 Data filename: \\albafilel\alba_Projects\2021\21-3100\213184\Design\Deslnfo\ComCheck\213184_Comcheck.c Page 12 of 12