Loading...
2003-649 (2) 1 3 2 17 3 J Jr 0)N �r Nr N Q Q r r p a tD N N tJ N to SS c `S 0 , OL CO N co 7411� �' 2 Af fordable Residential Communities FOREST PARK MHC 183 PITCHER ROAD QUEENSBURY, NY 12804 fl 96 6 �6 66 � PITCHER ROgp it f - x - f3� UN BATH ` LiV NG ROC IM BEDROOM 8 BEl7Rt1DM 3 .- BEDROOM E WALK-IN � KITCI4E�4 ClH 7-� lr N49r-4• r---------------------------------�------------------_ -I------------------------------__------_--- _-------_------------_---_------_-_,.------------------------------- i G7' 1 r y r i- I I 1 1 I I 1 or I f �5 I I r r I r I r r r I N I 1 1 i I 1 `-- . T_, r I I I I j 37' a 314•.ow I I I I SJ�W'afr-Bff I 9W -� r__...._� r__,,•...-ry r...._.«.__w , r-».r_..y r__...-....� r__.I.»... r_-...._y i i i I i i I r r I I i i i i i 'I 11 I 1 1 I 1 I I 1 1 1 1 h I i i i i i i R ---------t------4---------------T - __----T---------------T---------------T-- -------___=`-------------t--------------r---------------r Nrs" rrn 16g49-4' 133'4" 1.-s=�= 4. = " I--�'1 l 4r . er V ER NET i 7s'O' Pk►P►uft based on 2000 psf RrY�r ene■w.as-a2oxa�' } 1aK1betniag_p_jy...j. n,. ` �r�oap�faoxewdwapcb• ;ENR IAL NOTES.: T UNDER HIE. SCHULT HOMES CORP.. ODEL # (N)8016-499 - _ PIER SELI V S1 V J ,r NOTE: LONGITUDINAL TIEDOWNS ATTACHED TO THE " CROSSMEMBERS SHALL BE NO MORE THAN 3" FROM THE I—BEAM. LONGITUDINAL TIEDOWNS AND OUTRIGGERS NOT SHOWN FOR CLARITY. APPROVED BUCKLE g —I—BEAM APPROVED TIE— & LONGITUDINAL DOWN STRAPS TIEDOWNS PER CROSSMEMBER APPROVED ANCHOR WITH PAGE 4.19. SINGLE TENSIONING HEAD $ PIER BEYOND `^ ANGLE OF ANCHOR TO a GROUND BE IN LINE WITH STRAP FOOTING UNLESS APPROVED STABILIZER PLATE IS INSTALLED. 6- MAX. INSET TYPICAL.TIEDOWN REQUIREMENTS JA NOTE: LONGITUDINAL TIEDOWNS ATTACHED TO THE CROSSMEMBERS SHALL BE NO MORE THAN 3" FROM THE I—BEAM. LONGITUDINAL TIEDOWNS AND OUTRIGGERS NOT SHOWN FOR CLARITY. APPROVED BUCKLE APPROVED TIE—DOWN I—BEAM STRAP AND END TREATMENT (i.e. BUCKLE). STRAP SHOULD NOT / INTERFERE WITH CROSSMEMBER CONTENTS IN BELLY. i tittllllllttlJ — < — PIER BEYOND r \�\�w AR0�///f/� / r GROUND �`yQ 4�1 'ss / APPROVED ANCHOR WITH TWIN TENSION - E�aJi £ j HEAD. 372 = __ ALT. FOR SINGLE WIDES: STABILIZER PLATES I �naroz ` STRAP MAY LOOP COMPLETELY AROUND i—BEAM MUST BE INSTALLED AND ATTACH TO DOUBLE—HEADED ANCHOR ON WITH OTHERBE PROVIDED PER CORN R SIDE. PROTECTION MUST ANCHORSUBLE HEADED 6" MAX �i/iOI CAMN.t�'�0��\ INSET 11111111100 TYPICAL TIEDOWN REQUIREMENTS-CROSS-STRAPPING B Ram 1. SEE PAGES 4.14 TO 4.19 FOR TIEDOWN SPACING REQUIREMENTS. APPROVED TIEDOWN ,---APPROVED TIEDOWN STRAPPING 2. TIEDOWN STRAPPING, BUCKLES, ANCHORS AND END TREATMENTS ARE NOT BUCKLE --'� COMES OFF THE TOP OF THE SUPPLIED BY HOME MANUFACTURER. VERTICAL TIES ARE REQUIRED AT EACH [—BEAM. HORIZONTAL TIEDOWN ALONG THE SIDEWALL FOR WIND ZONES 2 & 3. 3. GROUND ANCHORS AND FRAME TIES SHALL BE CAPABLE OF RESISTING AN ULTIMATE TENSION LOAD OF 4725 LBS. (WORKING LOAD = 3150 LBS.) AND MUST BE INSTALLED PER MANUFACTURERS INSTALLATION INSTRUCTIONS. THESE ANCHORS ARE NOT TO EXTEND BEYOND THE SIDEWALL OF THE HOME. CUT PIECE OF STRAPPING 4. STEEL ANCHORING EQUIPMENT EXPOSED TO THE WEATHER,SHALL BE PRO— CROSSMEMBERS,PROTECT STRAPS AGAINST SHARP CORNERS AT I—BEAMS OR TECTED WITH AT LEAST 0.30 OZ. OF ZINC PER SQUARE FOOT OF STEEL. I—BEAM BEFE CUT A PIECE OF STRAPPING TO WRAP AROUND THE I—BEAM BEFORE 7N£ TIEDOWN STRAP IS WRAPPED AROUND THE 5. ANCHORING EQUIPMENT SHALL BE CERTIFIED BY A REGISTERED PROFESSIONAL MEMBER. ENGINEER OR ARCHITECT TO RESIST THESE SPECIFIED FORCES IN ACCOR— ALTERNATE: WRAP THE TIEDOWN STRAP COMPLETELY AROUND DANCE WITH TESTING PROCEDURES IN ASTM STANDARD SPECIFICATION 03953— THE I—BEAM TWICE. —91, STANDARD SPECIFICATION FOR STRAPPING, FLAT STEEL AND SEALS. ANOTHER ALTERNATE FOR SHARP CORNER 6. ANCHORS SHALL BE CERTIFIED FOR THESE CONDITIONS BY A PROFESSIONAL 'PROTECTION IS TO USE AN APPROVED CONNECTOR ENGINEER, ARCHITECT OR A NATIONALLY RECOGNIZED TESTING LABORATORY INSTALLED PER MFG. INSTRUCTIONS FOR RATED AS TO THEIR RESISTANCE, BASED ON THE INSTALLED ANGLE OF DIAGONAL TIE CAPACITY (3150 LBS. WORKING LOAD). AND/OR VERTICAL TIE LOADING AND ANGLE OF ANCHOR INSTALLATION, AND TYPE OF SOIL IN WHICH THE ANCHOR IS TO BE INSTALLED. 7. GROUND ANCHORS SHALL BE INSTALLED TO THEIR FULL DEPTH, EMBEDDED BELOW THE FROST LINE, AND BE AT LEAST 12" ABOVE THE WATER TABLE. SHARP CORNER PROTECTION 1C 8. STRAPS MUST BE TENSIONED PER TIEDOWN MANUFACTURER'S INSTRUCTIONS SO WIND ZONE 1 THEY WILL PERFORM AS DESIGNED.9. OVER—THE—ROOF TIEDOWN STRAPS ARE OPTIONAL AND NOT REQUIRED. THESE Strapping &Anchoring OVER—THE—ROOF STRAPS MAY BE USED TO PROVIDE ADDITIONAL STABILITY Requirements FOR SINGLE—SECTION HOMES, ABOVE AND BEYOND THE MANDATORY FRAME TIEDOWNS. PRAWN BY: JBM HBOS MPanufacturing, IO.LONGITUDINAL TIEDOWN STRAPS ARE ATTACHED TO PLANT WELDED BRACKETS ON THE DATE:11/30/98 MAIN [—BEAMS OR WRAPPED AROUND THE ENDS OF CROSSMEMBERS, MAXIMUM 3" FROM THE 1—BEAM. SEE PAGE 4.19 FOR SPACING AND ALTERNATE DETAILS. REv: 4/15/02 I-4.12 NOTE: LONGITUDINAL TIEDOWNS ATTACHED TO THE CROSSMEMBERS SHALL 'BE NO MORE THAN 3" FROM THE w 'I-BEAM LONGITUDINAL TIEDOWNS AND OUTRIGGERS NOT SHOWN FOR CLARITY. VERTICAL TIEDOWN -BRACKET IS INSTALLED IN, THE PLANT. (CAN BE ADDED OR RELOCATED IN THE FIELD 1F } NECESSARY TO MEET SPACING REQUIREMENTS. APPROVED BUCKLE BRACKETS ARE INSTALLED ACCORDING TO PAGE=4.21) -BEAM APPROVED TIE- AL . DOWN STRAPS CROSSMEMBER z -APPROVED ANCHOR WITH - TWIN TENSIONING HEAD $ PIER BEYOND 04 GROUND _ FOOTING STABILIZER PLATES MUST. ` BE INSTALLED WITH APPROVED 6" DOUBLE HEADED ANCHORS. MAX. INSET TYPICAL TIEDOWN REQUIREMENTS-NEAREST I-BEAM A NOTE: LONGITUDINAL TIEDOWNS ATTACHED TO THE CROSSMEMBERS SHALL BE NO MORE THAN_3" FROM THE [-BEAM. LONGITUDINAL TIEDOWNS AND OUTRIGGERS NOT SHOWN FOR CLARITY. VERTICAL TIEDOWN,-BRACKET IS - INSTALLED AN THE-PLANT. (CAN"BE ADDED-OR RELOCATED IN THE FIELD IF APPROVED BUCKLE NECESSARY.TO 'MEET'SPACING I=BEAM REQUIREMENTS. BRACKETS ARE STRAP SHOULD NOT INSTALLED ACCORDING TO PAGE 4.21). " INTERFERE WITH. CROSS CONTENTS,IN BELLY. �'^•�., _APPROVED TIE-DOWN • PIER BEYOND } STRAPS-AND END TREATMENT,,(i.e. BUCKLE). GROUND APPROVED ANCHOR WITH . TWIN TENSIONING HEAD STABILIZER PLATES MUST BE INSTALLED•WITH APPROVED :DOUBLE HEADED ANCHORS. ` 16- MAX. INSET TYPICAL.TIEDOWN REQUIREMENTS'-OPPOSITE I-BEAM B NOTES 1. SEE PAGES *14 TO 4.19 FOR TIEDOWN SPACING REQUIREMENTS. 2. SEE PAGE 4.12 FOR STRAPPING & ANCHORING •GENERAL, NOTES. AND TYPICAL •SHARP CORNER PROTECTION :DETAIL. CAR '. Q�:CAMP�Gi>>`� - !hrN11ui111���, ' WIND ZONES 2 &3 Strapping-'&Anchoring Requirements DRAWN 9Y:.•dBM HBO.Mpnufactu,ha, ,.. DATE:11 REV, 6/30/90 1-4.13 LJ w z z tF W V) Q 2( t FLOOR ASSEMBLY /-STRAP CONNECTED r- w FLOOR ASSEMBLY STRAPS CONNECTED CHASSIS m HASSI NEAREST I-BEAM s TO BOTH BEAMS. ONLY. t 00 USE DOUBLE HEADED ANCHORS. z z 4"�V WIND ZONE 1, TIEDOWN SPACING CHART WIND ZONE 1 TIEDOWN SPACING CHART HOME BOX I=SEAM MAX. TIEDOWN MAX. FLOOR ANCHOR HOME BOX I-BEAM MAX. TIEDOWN MAX. FLOOR ANCHOR SIZE WIDTH SPACING SPACING HEIGHT (H) ANGLE SIZE WIDTH SPACING SPACING HEIGHT (H) ANGLE 14 WIDE 168- 99 1/2- 8 ft. 43 In. 6'1' 14 WIDE 168- 99 1/2- 12 ft. 80 In. 48* 14 WIDE 168" 99 1/2" 10 ft. 31 In. 52" 16 WIDE 190- 99 1/2- 12 ff. 80 In. 48* 14 WIDE 168" 112" 8 ft. 32 In. 1 61' 6 WIDE J 1.90- 99 1/2- 12 ft. 78 in. 3T 14 WIDE 168" , 112" 10 ft. 23 In. 52- *INDICATES MAX. SIDEWALL HEIGHT OF 9'-7" 6 6 0 D 6 6 8 8 X WI DTH 16 WIDE 190- 99 1/2- 10 ft. 43 In. 52' 16 WIDE 190" 99 1/2- 12 ft. 31 In. 43* 16 WIDE* 190" 99 1/2' 8 ft. 51 In. 57* 16 WIDE* 190" 99 1/2' 10 ft. 35 In. 47- 16 D 190" 112" to ft. 35 In, 52 16 WIDE 1[90" 112" 12 ft. 25 In. *INDICATES MAX. SIDEWALL HEIGHT OF 9'-7" TIEDOWN SPACING REQUIREMENTS-NEAREST I-BEAM JAI TIEDOWN SPACING REQUIREMENTS-CROSSED STRAPS JB TYPICAL SIDE ELEVATION SHOWING TIE-DOWN SPACING 'TO OPPOSITE ANCHOR MAIN I-BEAM To OPPOSITE ANCHOR MAIN I-BEAM . . . . EACH STRAP MUST BE flT . . . ! * . . . . T I_B LOOPED AROUND THE I-BEAM A S CU E I LY T AND SECURED TIGHTLY TO EACH ANCHOR. TIE6OWN STRAPS DOUBLE HEADED ANCHOR. ANCHORS N-QM- SHARP CORNER PROTECTION MUST BE PROVIDED BY WRAPPING A PIECE OF 2 STRAP AROUND THE BEAM UNDER THE MAX MAX. TIEDOWN SPACING PER CHARTS,ABOVE MAX TIE-DOWN STRAP. TYPICAL SIDE ELEVATION SHOWING TIEDOWN SPACING F0 CROSSED STRAP DETAIL NOTES: 1. REFER TO PAGE 4.12 FOR ALL STRAPPING,AND ANCHORING REQUIREMENTS. 2. ROOF SLOPE MAY NOT EXCEED 20 DEGREES. MAX. EAVE IS 1 1/2". 3. MAX. SIDEWALL HEIGHT AS NOTED. .......... 4. BOX WIDTHS STATED ABOVE REPRESENT MAXIMUM WIDTHS FOR EACH HOME 0, WIND ZONE 1 SIZE. Z� q7 z: SINGLEWIDE SIDEWALL a 72 TIEDOWN REQUIREMENT ORAWN ElY.- JBM Manufa HRUM LP DATE:11/30/98 REV: 10/25/00 1-4.14 ' nFLOORASSEMBLY J > .dWFLOOR ASSEMBLY STRAP CONNECTEDrn,,, STRAP CONNECTED CHASSIS TO NEAREST aTO OPPOSITE 1—BEAM. 4 I—BEAM. VERTICAL TIES = VERTICAL TIES REQUIRE REQUIRE _ a-z-N ' p WIND ZONE 2 TIEDOWN SPACING CHART WIND ZONE 2 TIEDOWN SPACING CHART HOME BOX I—BEAM MAX. TIEDOWN MAX. FLOOR ANCHOR HOME BOX I—BEAM MAX. TIEDOWN MAX. FLOOR ANCHOR SIZE WIDTH SPACING SPACING HEIGHT (H) ANGLE SIZE WIDTH SPACING. SPACING HEIGHT H) ANGLE 14 WIDE 168" 99 1/2" 6 ft. 36 in. 54' 14 WIDE 168" 89 1/2" 6 ft. 65 In. 53' 16 WIDE 190" 99 1/2" 6 ft. 52 In. 54' 16 WIDE 190" 99 1/2" 6 ft. 65 in. 51' 16 WIDE* 190" 99 1/2" 6 ft. 33 In. 45' 16 WIDE" .190" 99 1/2" 6 ff. 65 in. 33' *INDICATES MAX. SIDEWALL HEIGHT OF 9'-7" *INDICATES MAX: SIDEWALL HEIGHT OF 9'-7" WIND ZONE 3 TIEDOWN SPACING CHART WIND ZONE 3 TIEDOWN SPACING CHART HOME BOX I—BEAM MAX. TIEDOWN MAX. FLOOR ANCHOR HOME BOX I—BEAM MAX. TIEDOWN MAX. FLOOR ANCHOR SIZE WIDTH SPACING, SPACING HEIGHT (H) ANGLE' SIZE WIDTH SPACING SPACING HEIGHT (H). ANGLE 14 WIDE 168" 99 1/2" 5 ft. 36 In. 54' 14 WIDE 168" 99 1/2" 5 ft. 65 In. 55' 16 WIDE 190" 99 1/2" 5 ft. 52 In. 54' 16 WIDE 190" 99 1/2" 5 ft. 65 in. 53' TIEDOWN SPACING REQUIREMENTS-NEAREST I-BEAM JAI TIEDOWN SPACING REQUIREMENTS-OPPOSITE I-BEAM IB TYPICAL SIDE ELEVATION SHOWING TIE—DOWN SPACING ` o FM TE TIEDOWN STRAPS & = ANCHORS MAX MAX. TIEDOWN SPACING PER CHARTS ABOVE MAX TYPICAL SIDE ELEVATION SHOWING TIEDOWN SPACING Ic NOTES; 1. REFER TO PAGE 4.13 FOR ALL STRAPPING AND ANCHORING REQUIREMENTS. ?. ROOF SLOPE MAY NOT EXCEED 20 DEGREES. MAX. EAVE IS 1 1/2". \\111��7111I�AR/'jtt/// S. MAX. SIDEWALL HEIGHT IS T-10" UNLESS OTHERWISE NOTED. Q ,�/ ��ii t. BOX WIDTHS STATED ABOVE REPRESENT MAXIMUM WIDTHS FOR EACH HOME Zti,.�4�ESS/�ti'��'� WIND ZONES 2 & S SIZE. '�± SINGLEWIDE SIDEWALL ~_ 3722 S TIEDOWN REQUIREMEN 1116/00 ��� DRAWN BY; ,IBM HBM Manufacturing, ......( E DATE;11 30 98 LP CAMA RfiC��� nEv. 9/25/00 I-4.15 FLOOR INSULATION DETAILS U_ FLOOR FRAMING A ell OUTRIGGER AREA BASEMENT (BELLY) AREA C)S OLITRIGGER co MN-1—BEAM R-33 FLOOR INSULWAO L L .............I..................... (2x6 FLOOR) O co SO BOTTOM BOARD R-22 (26 FLOOR) U_ 8,1 R-19 Ch T�� R-7 R-9 R-1 1 The details shown above illustrate the use of fiberglass insulation in 2x6 M and 2x10 floor construction. Refer to the Insulation Disclosure Form for specific information regarding the insulation. *— Compressed area. FORM FTC-002 09/16/93 (ALL) 919E DP32099 EXTERIOR 'WALE INSULATIONS DETAILS , -3 1/2 --7(1(-3 1/2a r /�--5 1/2" TOP PLATE (TYPICAL} INSTALLED THICKNESS INSTALLED INSTALLED THICKNESS THICKNESS INTERIOR INTERIOR INTERIOR SURFACE SURFACE SURFACE BOTTOM PLATE (TYPICAL) 2x4 2x4 26 (R-7) (R-1 1 MIN.) (R-19 MIN.) The details shown above illustrate the use of fiberglass insulation in 2x4 and 2x6 wall 'construction. The exterior iding'.and any sheathing that may be used is not shown. for sake of clarity., Refer to the Insulation Disclosure F&m for specific information regarding the insulation. — Compressed slightly: FORA FTC-003 09 1 6 W (ALL) '9/98 DP 32099 SINGLE WIDE VENTED ROOF INSULATION DETAILS INSULATION REDUCED TO PROVIDE FOR VENTILATION. (*2) 5E kMIMU FLAT CEILING THICKNESS AREA BLOWN IN INSULATION Mz M.4 INSULATION REDUCED TO PROVIDE FOR VENTILATION. (*2) BLOWN IN INSULATION CATHEDRAL CEILING AREA The details shown above illustrate the use of loose fill insulation in the vented roof cavity of a single wide home. Refer to the insulation Disclosure Form for specific information regarding the insulation. ADVERTISED VALUE (*2) R—VALUE AND THICKNESS WILL BE LESS THAN ADVERTISED AT SHALLOW END OF ROOF. FORM FTC-M 09/16/93 (M,P,N.B,R,L.H) 9/98 DP 32099 4 , —40 17 . pir c son yo rc '_ + ! �