Loading...
RC-0860-2021 .► Office Use Only SO—= ADDITION/ALTERATION PERMIT Permit#: ?Z —Og b O-ZO Zl APPLICATION Permit Fee: Town of Queensbwy 742 Bay Road,Queensbury,NY 12804 Invoice#: � P:518-761-8256 www.4ueensbury.net Flood Zone? Y Reviewed By:C�Oz) Project Location: JJ- J`f- Tax Map ID#: Subdivision Name: PROJECT INFORMATION: TYPE: Residential Commercial, Proposed Use: Single-Family _Two-Family _Multi-Family (#of units ) _Townhouse _Business Office _Retail _ Industrial/Warehouse —Garage (#of cars_) _Other(describe ) ADDITION SQUARE FOOTAGE: ALTERATION SQUARE FOOTAGE: 1st floor: I 8 [ 1st floor: 2nd floor: 76 2nd floor: 3rd floor: 3rd floor: Basement(habitable space): Basement (habitable space): Total sq ft: /-5. Total sq ft: - "A b ., Scope of work to be done: D EC E0 E DEC 0 3 2021� TOWN OF QUEENSBURY BUILDING &CODES Addition/Alteration Application Revised January 2021 CONTACT INFORMATION: PLEASE PRINT LEGIBLY OR TYPE, PLEASE INCLUDE AN EMAIL • Applicant: Name(s): Mailing Address, C/S/Z: ,Uo x 6, :S7 C- L-1 %t&-PP��E �) i��`Z� Cell Phone: Land Line: 6 S6 9°S 7 3 Email: Odl L Lc nc_ • Primary Owner(s): Name(s): Lt ,s 14 Ili u-s Mailing Address, C/S/Z: o 33 1�,o Cell Phone: Q1 '7 8 e 3 4'7 Land Line: Email: Q.s1 61f41L& J4" � ��� � � , ��►'� ❑ Check if all work will be performed by property owner only • Contractor(s): (List all additional contractors on the back of this form) Contact Name(s): cAouP, itj e--. Contractor Trade: 6 ,X'Ab g,r9- I- Crcl N T �Tin�6 Mailing Address, C/S/Z: Box, S - C t-1c.Ji�:-",6L#-F- 00/ Cell Phone: :51 F ) 7 Zb 4. o R3 Land Line: �'/T ) L 5% '?5 73 Email:-- d/ t-c- a, -zs�K [ A)p 6 1- iDA--r- , e-�o rrl **Workers' Comp documentation must be submitted with this application** Architects Eneineer(s): Business Name: Contact Name(s): 4/Z« —, r,- j2A s Mailing Address, C/S/Z: .7 n L-Axe. lSrse a �,D , 4os2T le Al N��J�,Y Cell Phone: ( S) g ) zy3 S/ Land Line: � ) Email: 6 r6-9,9 s 0� ' /y o , co /"I Contact Person for Compliance in regards to this project: _ od/ e- N/19-s o 0 Cell Phone: ,3) 9 ) 7 P,6 6 0 17,3 Land Line: S1 .6 d-6 4'g,5- 7-:3 . Email:-- 0) L-i- �+. �f�Kua4Fu7/.A t!:- Addition/Alteration Application Revised January 2021 ADDITIONAL PROJECT INFORMATION: 1. Estimated Cost of Construction: $ 2. Source of Heat (circle one):_Gas —Oil _Propane _Solar X Other 0 cX C-rAle. r3Jr-<CP'0X4'A0 Fireplaces/inserts need a separate Fuel Burning Appliances & Chimney Application 3. Are there any structures not shown on the plot plan? YES XNO Explain: 4. Are there any easements on the property? YES NO SITE INFORMATION: • Is this a corner lot? _YES ENO • Will the grade be changed as a result of the construction? _YES ><NO • What is the water source? J6 PUBLIC _PRIVATE WELL (7 Xun�D���DE kld3" � • What type of wastewater system is on the parcel? ASEWER _PRIVATE SEPTIC �v M &J l L L- coo A)N E DECLARATION: 1. 1 acknowledge that no construction shall be commenced prior to the issuance of a valid permit and will be completed within a 12 month period.Any changes to the approved plans prior to/during construction will require the submittal of amended plans,additional reviews and re-approval. 2. If,for any reason,the building permit application is withdrawn,30%of the fee is retained by the Town of Queensbury.After 1 year from the initial application date, 100%of the fee is retained. 3. Ifthework is not completed by the 1 year expiration date the permit may be renewed, subject to fees and department approval. 4. 1 certify that the application, plans and supporting materials are a true and a complete statement and/or description of the work proposed,that all work will be performed in accordance with the NYS Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. 5. 1 acknowledge that prior to occupying the facilities proposed I, or my agents, will obtain a certificate of occupancy. 6. 1 also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: PRINT NAME: l� L�' 1Jjja��►'? M )t-SoA) SIGNATURE: DATE: Addition/Alteration Application Revised January 2021 SEPTIC DISPOSAL PERMIT office use only APPLICATION Permit#: C(— Town of Quccnsbury Permit Fee:$ Invoice#: 742 Bay Road,Queensbury,NY 12804 P:518-761-8256 www.gueensbury.net Septic Variance? Y N Flood Zone? Y N Wetlands? Y N Reviewed By: Project Location: v-n v 9-14 0 Lf—j 4y Tax Map #: 2 3 9. 8 RESIDENCE INFORMATION: Year Built Gallons #of bedrooms: X gallons per =total daily flow per day bedroom Garbage Grinder Yes No 1980 or older 150 4 o o Installed? (choose one) ❑ 1981-1991 130 Spa or Hot Tub Yes No 1992-Present 110 Installed? (choose one) ❑ PARCEL INFORMATION: Topography Flat Rolling ❑ Steep Slope % Slope Soil Nature ❑ Sand 'Loam ❑ Clay ❑ Other, explain: Groundwater At what depth? Bedrock/Impervious material At what depth? Domestic Water Supply ❑ Municipal ❑ Well ❑Lake (if well or lake, water supply from any septic system absorption is ft.) Percolation Test Rate: per minute per inch (test to be completed by a licensed engineer/architect) PROPOSED SYSTEM INFORMATION: Tank size gallons (min. size 1,000 gallons, add 250 gallons for each garbage cylinder or spa/hot tub System Absorption field w/#2 stone Total length ft.; Each Trench ft. Seepage Pit w/#3 stone How many: ; Size: Alternative System Bed or other type: Holding Tank System Total required capacity? ; tank size # of tanks fl-D D tir-o M -V-04K u tj p&d #oN g-ocJ -- ,5 p1M a a9 Septic Application Revised April 2021 CONTACT INFORMATION: PLEASE PRINT LEGIBLY OR TYPE, PLEASE INCLUDE AN EMAIL • Applicant: Name(s): It I fl-w� irrsc rJ Mailing Address, C/S/Z _lQoy, Ss, c 1FE,Y46- 4.0 p %,.E Cell Phone: Land Line: 73 Email:' jai L )o E_ , Q�o� • Primary Owner(s): Name(s): c,i,3 4 P ?C_i4ya ws Mailing Address, C/S/Z: la 3 3 1'� '� ��', V.0 o K rto, tay i Cell Phone: q 17 - g198 P,b 347Land Line: Email: _ I's sA ,p•-Qio.n�ts @,, �••,a.: 1 . e.Q,r... ❑ Check if all work will be performed by property owner only • Contractor: Contact Name(s): G K Y-i 3 Contractor Trade: f- x c�4 r Mailing Address, C/S/Z: t, -s woo-ye, ,ac.K F3�.-. u-P. I�I� o-+Eor�b4-.)IJ y Cell Phone: Land Line: Email: "Workers' Comp documentation must be submitted with this application" • Eneineer(s)• Name(s): kT�-rtr�JS Mailing Address, C/S/Z: j56+L)i4.ft,0p R-0 S�U4f-1J.s.8eA ��,► i Cell Phone: land Line:_5I"a' 7 0 S-y-0 3 07 Email: _7'#u-rd -lA)s H-t471_-�/Pt5 enl &Id i Ria ra . c.0n Contact Person for Compliance in regards to this project: A) f 4.c-/A_ r7 o**#) ,ems C�,J Cell Phone: Land Line: S-6-g3- Email: -,gi 7777/�Kc pAjc a).0, , c.oP-1 NOTES: 1. Alarm system and associated electrical work must be inspected by a Town approved electrical inspection agency; 2. We will no longer allow systems to be covered until such time as an as-built plan is received and approved. The installed system must match the septic layout on file—no exceptions. 3. As- built drawings must be submitted prior to the inspection, if there has been a change to the submitted plans. 4. If, for any reason, the building permit application is withdrawn, 30% of the fee is retained by the Town of Queensbury. After 1 year from the initial application date, 100% of the fee is retained. Declaration: Any permit or approval granted which is based upon or is granted in reliance upon any material representation or failure to make a material fact or circumstance known by or on behalf of an applicant, shall be void. I have read the regulations and agree to abide by these and all requirements of the Town of Queensbury Sanitary Sewage Disposal Ordinance. PRINT NAME: !N t�t-1�4 v+1 �✓i+�S o� SIGNATURE: DATE: Septic Application Revised April 2021 Residential Plan Review: 1- and 2- Family Dwellings Y/N/NA (1 of 2) ��. Two (2)full sets of plans Over 1,500 sq. ft. requires engineering stamp ,j,6( Design loads on plans: 115 Wind Floor Loads 40 psf `1 l (North of Rte. 149 60) 50 Ground Snow Load Sleeping Areas &Attics 30 psf Calculations Decks 40 psf Wind design for lake front properties + � Window schedule with glass size & main doors/Air leakage < .5 cfm for doors, < .3 cfm for l windows/Tempered glass in bathrooms Door schedule/Main entrance 36" door Emergency Escape or Bedrooms & Habitable Space Above-grade: 5.7 sq. ft. Grade: 5.0 sq. ft. 24" (h)x 20" (w) minimum 44" maximum height above door indoor control devices 24" or less 2nd story or 72" above grade Egress window from basement 5.0 sq. ft. IL Floor system sizing per table 5 Residential check E r Prescriptive method M Ac Driveway length: 300' or more— 2' iiidth required/500' or more,turnaround required Foundation drainage on plans, if required 6" drop in 10' exterior grade Framing cross section for each roof line, vertical fire stopping every 10' where required/joist spans pg. 127 Ice & snow shield —24" from exterior wall Platforms at exterior doors Stairway headroom 6'8"; all stairs 36" width Stair run and rise � Winder run and rise Spiral stairs meet requirements Smoke detectors—battery backup & proper location, interconnected Bathroom fixtures—proper clearance r Hall width-36" width Handrails more than four risers on open sides Railing&guards >30"/basement stairs included/closed risers more than 4" in height Safety glazing notes for required areas f Garage fire separation:%" gable end/5/8" under living space &%" on walls/20 min. door and closer Garage floor sloped Attic access: gasket seal & R-value equal to roof insulation Roof over 30"—22"x 30"/Crawl spaces 18" x 24" access Continued on back 4 4 Residential Plan Review Revised October 2021 Residential Plan Review: 1- and 2- Family Dwellings Y/N/NA (2 of 2) Carbon Monoxide detector outside lowest sleeping area, on every level & interconnected within 15' of sleeping arean2 _ Soil test results, if re uir Septic toA*L- or water line separation Z All paperwork signed Note on plans energy saving light bulbs 90% Blower door test agency paperwork Floodplain Permit required—check map: 2 feet above flood elevation Hurricane clips required MA-Floors less than 2 x 10 covered by%" gypsum or 5/8" wood panel Manuals S &J required for heating system. Cold air return hard piped Separate room for draft HVAC or hot water heater with fresh air A- HRV shown and calculations Baffles at eaves for insulations and knee walls Xf Makeup air for range hood >400 cfm OkContinuous header for garage doors to end wall Chimney rain cap shown for fireplaces ' -Deck hold down shown not less than 4 lags and bolts per table 507.2 Residential Plan Review Revised October 2021 Generated by REScheck-Web Software Compliance Certificate Project Paplanus Residence 2nd floor addition EI L COPY Energy Code: 2018 IECC Location: Warren County, New York Construction Type: Single-family Project Type: Addition Y� Climate Zone: 6 (8499 HDD) Permit Date: Permit Number: Construction Site: Owner/Agent: Designer/Contractor: 15 Tuscarora Drive Lisa Paplanus Designer:Eric Teras Town of Queensbury Contractor:Takundewide Mgt. Cleverdale,New York 12820 Group(Bill Mason) Compliance: 11.3%Better Than Code Maximum UA: 115 Your UA:~102 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate or energy use or cost relative to a minimum-code home. Slab-on-grade tradeoffs are no longer considered in the UA or performance compliance path in REScheck.Each slab-on-grade assembly in the specified climate zone must meet the minimum energy code insulation R-value and depth requirements. Envelope Assemblies Ceiling:Cathedral Ceiling 858 49.0 0.0 0.022 0.026 19 22 Wall:Wood Frame, 16"D.C. 896 21.0 6.0 0.041 0.045 29 32 Window:Wood Frame 184 0.260 0.300 48 55 Wall 1:Wood Frame,16"D.C. 144 21.0 6.0 0.041 0.045 6 6 Compliance Statement: The proposed building design described here is consistent with the building plans,specifications,and other calculations submitted with the permit application.The proposed building has been designed to meet the 2018 IECC requirements in REScheck Version:REScheck-Web and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Eric Teras Designer �jr: 12/08/2021 Name-Title Signature Date Project Title: Paplanus Residence 2nd floor addition Report date: 12/08/21 Data filename: Page 1 of 9 REScheck Software Version : REScheck-Web Inspection Checklist Energy Code: 2018 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement,the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section Plans Verified` Field Verified. Pre=Ins ection/Plan .• , ' - p_ '� �` Review` Complies? , Comments%Assumptions. &'Req.ID Value .. Value; 103.1, :Construction drawings and ❑Com lies 103.2 documentation demonstrate ❑Does Not [PRll �ener codecom compliance l 9Y P `x:building envelope. _ <b":❑Not Observable y 9 P Thermal ;: :, ;env . ,,;_,>r; r : <;` []Not A licable elope represented on t , r: : PP construction documents. 103.1, ;Construction drawings and e` - _ - ', _ .{❑Com lies 103.2, documentation demonstrate i' '' :4r,❑Does Not 403.7 ;energy code compliance for PR3 1 :lighting and mechanical s stems. ,;?;<_ ;.y,_:. s r; .°i :: ; J ❑Not Observable [ ] 9 9 Y N•j tr'F7,y'< i❑Not Applicable Systems serving multiple ;;:`.•.;5,';�_�.:_.��r „, - ,,;.�;;_,_ _ _ _ .:, PP , :dwelling units must demonstrate ;compliance with the IECC Commercial Provisions. 302.1, ;.Heating and cooling equipment is!' Heating: Heating: ;❑Complies 403.7 sized per ACCA Manual S based Btu/hr Btu/hr :❑Does Not [PR2]2 ;on loads calculated per ACCA Cooling: Cooling: ,0 ;Manual J or other methods Btu/hr Btu/hr ❑Not Observable approved by the code official. ; ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Paplanus Residence 2nd floor addition Report date: 12/08/21 Data filename: Page 2 of 9 Section # Foundation Inspection. Complies? Comments/Assumptions•. & Reob 303.2.1 ,A protective covering is installed to ;❑Complies j [F011]Z !protect exposed exterior insulation ElDoes Not land extends a minimum of 6 in.below : � ;grade. !❑Not Observable ❑Not Applicable 403.9 ;Snow-and ice-melting system controls;❑Complies [FO12]2 installed. UDoes Not ;❑Not Observable; ;❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Paplanus Residence 2nd floor addition Report date: 12/08/21 Data filename: Page 3 of 9 ,section* Plans Verified Rield.Verified # Framing'/Rough-ln Inspection Complies? Comments/Assumptions &:Req:ID Value .. ; Value 402.1.1, :Glazing U-factor(area-weighted U- U- ;❑Complies ;See the Envelope Assemblies 402.3.1, ;average). ;❑Does Not ;table for values. 402.3.3, 402.5 ;❑Not Observable [FR2]1 ; ;❑Not Applicable I 1 1 1 303.1.3 products U-factors of fenestration 1 P ❑Complies [FR4] are determined in accordance ❑Does Not ;with the NFRC test procedure or a ; �j .,,,❑Not Observable ; ,taken from the default table. .-�❑Not Applicable 402.4.1.1 ;Air barrier and thermal barrier ; = .?ai''`- :,❑Complies [FR23]1 ;installed per manufacturer's "I`` ;❑ P Does Not instructions. 3 ` .. ._,❑Not Observable ;;❑Not Applicable 402.4.3 ;Fenestration that is not site built ❑Complies [FR20] -is listed and labeled as meeting ❑Does Not AAMA/WDMA/CSA 101/LS.2/A440 ' - =rt:r�`.• - - :or has infiltration rates per NFRC = - :<<::" -- ,❑Not Observable , 400 that do not exceed code ,❑Not Applicable ; limits. <>, 402.4.5 ;IC-rated recessed lighting fixtures;':`'s': ' ';° ; `'"` 4 "I} '' -- Y. "' " ❑Com lies [FR16]2 ;sealed at housing/interior finish ;.; ;;,,1;. 3.• .y. :_:7ayy_ ;,; ,,; r:❑Does Not ; ;and labeled to indicate:52.0 cfm `a leakage at 75 Pa '❑Not Observable ,,,❑Not Applicable 403.3.1 ;Supply and return ducts in attics ;` -`=?; " ❑Complies FR12 1 ;insulated>_ [ I R-8 where duct is ❑Does Not 3 inches in diameter and>_ I ❑Not Observable 3 inches.Su , R-6 where< Supply and returnt _';' =- ' " =' ❑Not Applicable ducts in other portions of L. _ _ __ _ the >_ - building insulated R 6 for diameter>=3 inches and R-4 2 '47 !for<3 inches in diameter. 403.3.2 ;Ducts,air handlers and filter 'i^ ❑Complies [FR13]1 ;boxes are sealed with `° _ ❑ Does Not joints/seams compliant with ' ❑Not Observable ' ;International Mechanical Code or , ,:,• `'.;,:_, -,,.r> ` ,,,,lr_,' .; ,z .International Residential Code,as; i'a-. ; '" —z= ';❑Not Applicable j 'applicable. 403.3.5 ;Building cavities are not used as „-, = - r` ❑Complies [FR15]3 !ducts or plenums. []Does Not ❑Not Observable ' ❑Not Applicable ' 403.3.7 Ducts declared to be within the ❑Com lies FR28 3 !conditioned space are either 1 P ; [ ] P ) ❑Does Not :completely within the continuous Lt+!) p y ; F ❑Not Observable ;air barrier and within the building ;thermal envelope,2) buried r-:..`'= ,`' _ _ ` .=': ❑Not Applicable within ceiling insulation in ,accordance with Section ;R403.3.6 and the air handier is ;located completely within the continuous air barrier and within ,the building thermal envelope :and the duct leakage is<= 1.5 ;cfm/100 square feet of ;conditioned floor area served by the duct system,or 3)the ceiling - . insulation R-value installed ;against and above the insulated >_ ;duct to the proposed ceiling Y• ,insulation R-value,less the R- ;value of the insulation on 1 I High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Paplanus Residence 2nd floor addition Report date: 12/08/21 Data filename: Page 4 of 9 Section `` . Plans;Verified Field Verified .' Framing/Rough=ln'Inspection ' Complies? Comments/A"ssumptions & Req':ID :.. Value" Value 403A. ";HVAC piping conveying fluids R- R- ElComplies [FR17]? -above 105 QF or chilled fluids ❑Does Not below 55 QF are insulated to>_R- «' ` 13 ;❑Not Observable ' ❑Not Applicable 403.4.1 ;Protection of-insulation on HVAC ', = ':t 4-_x 'N ;❑Complies [FR2411 piping. 4:: ;` ;<E.. }.l>>:.`j;❑ q>�f: �;:, _ -_���-`:�r;�,`' v� Does Not - i � '.sue°��°` _= - ., �;� '_�� �,�;,- - - _ _, ❑Not Observable ❑Not Applicable 403.5:3 ;Hot water pipes are insulated to R- R-.._ ;❑Complies [FR18]2 I>_R-3. PDoes Not g' ;❑Not Observable !❑Not Applicable 403.6 ;Automatic or gravity dampers are `r:;:° ';' ;5 i=*R{ ' " '' - '=a;❑Com lies '2. .r>�',�R; (.,.�� art. p [FR19] . installed on all outdoor air ',:> ` ,' -!❑ Does Not intakes and exhausts. Not Observable f.': a'ft`-'t ~?.y'•Ct''(Tfi'y��?�•�"r'wu".:'`.`iri�:.j ❑Not Applicable , Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Paplanus Residence 2nd floor addition Report date: 12/08/21 Data filename: Page 5 of 9 Section. ;<. mns•.Vetified,•; Field-Ve'-ified #`..`. Insulation lnspection. - - - - -Complies?- -Comments%Assumptions- & RegslD, . Value :: ..' Value 303.1 iAll installed insulation is labeled ❑Com lies IN13 Z o _ r _ ; . 4=, F°r `bb ,: [ ] r the installed R values '- , 2,. L`{':?=-t El Not ;provided. E]Not Observable ❑Not Applicable ; 402.1.1, :Wall insulation R-value.If this is a: R- L. R- ;❑Complies ;See the Envelope Assemblies 402.2.5, :mass wall with at least'/2 of the ❑ Wood El ;❑Does Not ;table for values. 402.2.6 ;wall insulation on the wall ;❑ Mass ❑ Mass ;❑Not Observable ' [IN3)1 ;exterior,the exterior insulation requirement applies(FR10). ;❑ Steel ❑ Steel ❑Not Applicable 1 ; ; 1 , 1 303.2 ;.Wall insulation is installed per ❑Complies IN4 :manufacturer's instructions. [ ] :: }' ❑ -�`a Does Not ❑Not Observable E]Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Paplanus Residence 2nd floor addition. Report date: 12/08/21 Data filename: Page 6 of 9 Section J ;Plans Verified Field Verified Final Inspection Provisions Value Value complies? Comments/Assumptions - 402.1.1, ;Ceiling insulation R-value. R- R- ;❑Complies ;See the Envelope Assemblies 402.2.1, - ❑ Wood ;❑ Wood ;❑Does Not table for values. 402.2.2, ❑ Steel ❑ Steel �❑Not Observable 402.2.E[Fill' i❑Not Applicable , 303.1.1.1,;Ceiling insulation installed per ❑Complies P ti y, 303.2 imanufacturer's instructions. ❑Does Not [FI2] ;Blown insulation marked every ❑Not Observable ❑Not Applicable ' - - - y" - ' _:.l,:x,._a.o 402.2.3 ;Vented attics with air permeable ❑Complies [FI22]z baffle . !insulation include bae adjacent a� " " ;. jr. ` „❑ i 1•,: �� ��; ;r:; ;hh Does Not to soffit and eave vents that = -•,r=:u s %+a';`=❑Not Observable ;extends over insulation. ❑NotApplicable 402.2.4 ;Attic access hatch and door R i R- ;❑Complies [FI3]1 :insulation>:R-value of the ;❑Does Not adjacent assembly. ,❑Not Observable ❑Not Applicable 402.4.1.2 ;Blower door test @ 50 Pa.<=5 ACH 50= ; ACH 50= ;❑Complies [FI17]1 ach in Climate Zones 1-2,and PDoes Not <=3 ach in Climate Zones 3-8. j ,❑Not Observable ' ❑Not Applicable ' 403.3.3 ;Ducts are pressure tested to cfm/100 cfm/100 ;❑Complies [FI27]1 determine air leakage with ftZ ftz PDoes Not either: Rough-in test:Total leakage measured with a ; ,❑Not Observable pressure differential of 0.1 inch ; ;❑Not Applicable ;w.g.across the system including ;the manufacturer's air handler ,enclosure if installed at time of 1 test.Postconstruction test:Total 1 , leakage measured with a pressure differential of 0.1 inch i ;w.g.across the entire system ;including the manufacturer's air ; :handier enclosure. I i 403.3.4 ;,Duct tightness test result of<=4 ; cfm/100 cfm/100 ;❑Complies [FI4]1 :cfm/100 ft2 across the system or 1 ftz ftz ❑Does Not <=3 cfm/100 ft2 without air ;handler @ 25 Pa.For rough-in ; ,❑Not Observable ;tests,verification may need to :❑Not Applicable ;occur during Framing Inspection. 403.3.2.1 'Air handler leakage designated ; ' '❑Com lies [FI24] :by manufacturer at<-2/o of �s� ;;;;• 1 � nor=={�� �_;�°�- :�❑Does Not design airflow. Not Observable >Y _ ..,,❑ :]Not Applicable 403.1.1 ;Programmable thermostats ,❑Complies z `_.� ti::i='` _ •, �'rN"-- -- - �'� [Fl9] i installed for control of primary .a' ,-- ❑Does Not 1 heating and cooling systems and `i''- ;�T• - ;:' Not Observable i initial) set b manufacturer to Y Y ��� - r` i:3''z ❑Not A (code specifications. PPlicable 40 .1.2 'Heat pump thermostat installed 'r ':?== ::_ s.==`i'.'❑Com lies [FI10] ,on heat pumps. k.: r _ - - ;i❑Does Not Not Observable ' ❑Not Applicable 403.5.1 Circulating service hot water w a ❑Complies [Flll]? 'systems have automatic or ❑Does Not accessible manual controls. , r�:•��<- _ tip" �c.�:���- �..���'°_a❑Not Observable ❑Not Applicable 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Paplanus Residence 2nd floor addition Report date: 12/08/21 Data filename: Page 7 of 9 Section . Plans;Verified Field.Verified # Final Inspection`Provisions: Complies? Comments/Assumptions &",;Req:ID Value . Value ' II mechanical ventilation system �^ :•- .,:. :z;❑Complies [FI25]2 ;fans not part of tested and listed ❑ Does Not HVAC equipment meet efficacy ` - = ''❑Not Observable ;and airflow limits per Table - -- - ,�`""-��`'`" '`_'" ' R403.6.1. yi❑Not Applicable 4032 i Hot water boilers supplyingheat 'J' 'W = _ TM-� I I� _ --_ _- _ <„•:�,.-;Y-�� •.,❑Complies [FI2fi]z ,throw h one-or two- i e heating 1``N' "f`", ' 9 P P 9 "; tlrl . <yY' t ❑Does Not :systems have outdoor setback ' ❑Not Observable control to low I er boiler water .1 I ;temperature based on outdoor fs'" - - a> rc `;❑Not Applicable ; ;temperature. 403.5.1.1 ;Heated water circulations stems ❑Com lies [FI28]2 ;have a circulation .The um P P ,,,> ❑Does Not system return pipe is a dedicated ,;=-' ` []Not Observable ' return pipe or a cold water supply,. _ S❑Not Applicable ;pipe.Gravity and thermos- ;syphon PP circulation systems are �;,'; �•- I not resent.Controls for P circulating hot waters stem pumps start the pump with signal ;for hot water demand within the occupancy.Controls automatically turn off the pumpwhen water is in circulation loop :is atset-point temperature and ;no demand for hot water exists. Zy ti t• 'I 403.5.1.2 ;Electric heat trace systems ❑Comp lies [F129]2. :comply with IEEE 515.1 or UL 'i[_""N w ':: =' I ; I -r - --- - ":,,;,,:;.�t - - ' •,_.:_❑Does Not ;515.Controls automatically _`'•-`" �'"`_" ,•.''� _ _ 3; = `` _ ; ;adjust the energy input to the `'" �:��:�.' - - ))❑Not Observable heat tracing to maintain the �`;; ,;; ;`- ' '' '';='t;€S:c>t?,'^`;`'' >,,❑Not Applicable ; desired water temperature in the ;piping. 4035.2 ;Demand recirculation water 4 "' �s _''':•' ':: '+-v %' ❑Complies [F136]2- ;systems have controls that ❑Does Not :manage operation of the pump -- >? ;_.,❑Not Observable ,and limit the temperature of the :, = . ,,:: - h,' ❑Not Applicable I water enteringthe cold water ' piping to<= 1044F. ',r`:;e 403.5.4_ :Drain water heat recovery units ❑Complies [FI31]2 ;tested in accordance with CSA ❑Does Not ;B55.1.Potable water-side pressure loss of drain water heat E - ❑Not Observable ' ;recove units< i f J Yf~` . ` ❑Not A licable :individual ry 3 psi or 1, �:.{"_e' - _,,;=`�°,'� n:�- • _� PP ; ,individual units connected to one _` ai•f, _ , or two showers.Potable water- ;side pressure loss of drain water I.•u ='- __. heat recovery units<2 psi for 'individual units connected to ' ,three or more showers. 404.1 ;90%or more of permanent „ s . . Co [F16 1 :fixtures have high efficac lamps. ❑Do es Not ; ❑Not Observable ' a: .:�r;:,.- a'%,rt>'.t:':';==' ❑Not Applicable 404.I:1. !Fuel gas lighting systems have ❑Com plies [F12313 !no continuous pilot light. ❑ - Does Not � :i ' ❑Not Observable ❑Not Applicable 461.3 ;Compliance certificate posted. ❑ Complies ' [FI7]'z 1=.• __ F' —Does Not ; ❑Not Observable .,![]Not A PPlicable 1 1 High Impact(Tier 1) 12.1 Medium Impact(Tier 2) 131 Low Impact(Tier 3) Project Title: Paplanus Residence 2nd floor addition Report date: 12/08/21 Data filename: Page 8 of 9 section Plans Verified Field Verified_ " # Final Inspection.:Provisions .Complies? ' Comments/Assumptions & Re q.ID Value: Value 303.3. ,Manufacturer manuals for . _- -A. 5 - i❑Complies [FI18] ;mechanical and water heating y `r;.i.:. -_ - ❑Does Not ;systems have been provided. IV' ._';:,fit`';,,`•` ;. {<<;=, -]Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 1,3'°`J Low Impact(Tier 3) Project Title: Paplanus Residence 2nd floor addition Report date: 12/08/21 Data filename: Page 9 of 9 2018 iECC Energy Efficiency Certificate p Above-Grade Wall 27.00 Below-Grade Wall 0.00 Floor 0.00 Ceiling / Roof 49.00 Ductwork (unconditioned spaces): C t• 11 Window 0.26 Door Heating System: Cooling System: Water Heater: Name: Date: Comments T .j "� •' y�� . I = 7 w, . . 'sire ir tz ► . s Oil so ' + - 'f t J.ii, ♦. .'}. '-0lit:7aC.4,'t!�'t?Y.tt'h. Al , , '.• . � .� 169 Haviland Road Queensbury, NY 12804 Hutchins Engineering PLLC Phone: (518)745-0307 9 9 Fax: (518)745-0308 PE December 6, 2021 DEC 0 6 Town of Queensbu Buildings and Codes 74.S Bay Road ry g TO BUILDING&ECODSSRY Queesbury, NY 12804 Reference: Takundewide Sewage Works Corporation Centralized Wastewater System Connection of Cabin #15 to Centralized System Our office designed the centralized wastewater system serving 8 private cottages within the Takundewide Homeowners Association. The system was constructed in 2008 and has a design capacity of 3630 GPD. Based upon design flow data, water usage information and existing building connections, there is available capacity in the system to serve proposed 4-bedroom cabin 15. Attached is a system record plan showing proposed connection of cabin #15. Should you require additional information or wish to discuss, please feel free to contact me. Regards, U�1 , G. T omas Hutchins, P.E. Cc. Bill Mason; Takundewide G.Thomas Hutchins,P.E. . To: Town of Queensbury, NY No. of pages including this page: 11 Buildings & Code Enforcement . Aft: Mr. Charles Dyer From: Eric Teras Northern Design CC: Bill Mason Takundewide Management Group inc. Date: December 8, 2021 Et - CIO Re: Residential Addition/renovation plans for Lisa Paplanus 15 Tuscarora Dr.,Cleverdale, NY 12820 Mr. Dyer, he following is per our phone converstion today. This letter is a addendum to the permit plans dated 11-18-2021 Items below are to be included in construction/permit plans. 1.The ceiling insualtion as shown on pg. 3, cross section "A"of the permits plans is to be changed from R-38 to R-49 The use of electric heat requires the Energy Code to follow the Prescriptive path for compliance. Attached is the revised REScheck with R-49 ceiling insulation. Included is the Inspection Checklist and Energy Efficiency Certificate. Please feel free to call or email if you have any other questions. Respectfully Eric Teras eteras@yahoo.com 518-223-5152 MAINTENANCE PLAN � RIM=329.65 INDIVIDUAL SEPTIC TANKS CONNECTED TO COMMUNITY SYSTEM �, ANNUALLY OPEN ACCESS COVERS, INSPECT TANK STRUCTURE, BAFFLES AND PIPING. CLEAN EFFLUENT FILTERS AND INSPECT SOLIDS / s Pvc / INV. 32&30 ACCUMULATION. TANKS ARE TO BE PUMPED BY A LICENSED SEWAGE HAULER WHEN THE SOLIDS ACCUMULATION REACHES 113 OF THE LIQUID DEPTH OF THE TANK. REGARDLESS OF SOLIDS ACCUMULATION, TANKS ARE TO BE PUMPED AT A 3—YEAR MAXIMUM TIME INTERVAL. / 6' Pvc ►NV. 327.44/ yyy MANHOLES 8' PVC ANNUALLY OPEN MANHOLE COVERS, INSPECT STRUCTURE AND PIPING AND CHECK FOR ANY SOLIDS ACCUMULATION OR LEAKAGE. ANY CB-5 INV. 32739 SOLIDS ACCUMULATIONS ARE TO BE PUMPED BY A LICENSED SEWAGE HAULER. c RIM=329.14\ / / \ 8' PVC INV. 327.32 PUMP STA TIONS 13-4 RIM=329.57 ANNUALLY OPEN PUMP STATION HATCHES, INSPECT STRUCTURE, PIPING AND FLOAT SWITCHES. CHECK FOR ANY SOLIDS ACCUMULATION. ANY SOLIDS ACCUMULATIONS ARE TO BE PUMPED BY A LICENSED SEWAGE HAULER. MANUALLY ACTIVATE "LAG PUMP ON" FLOAT TO VERIFY / s" Pvc / C / INV. 327.37 THAT AUDIBLE AND VISUAL ALARM IS ACTIVATED. MANUALLY ACTIVATE HIGH LEVEL ALARM FLOAT TO VERIFY THAT SOLENOID VALVE ON COMMUNITY WATER SYSTEM IS CLOSED AND THAT THE AUTODIALER FUNCTIONS PROPERLY. ounEr TO LAKE (NOT SURVEYED) // 330 ABSORPTION FIELDS ,� `• \ TURF ESTABLISHED ON ABSORPTION FIELDS IS TO BE MAINTAINED AS LAWN AREA. ANNUALLY INSPECT ABSORPTION FIELDS FOR SIGNS OF \ i SEEPAGE OR OTHER SIGNS OF FAILURES WHICH ARE EVIDENT AT E SURFACE. IN132Z3s2- CUP V.IMN,� 9..2 INV. 6.5J / 25 CABINS SHOWN HATCHED TO 12' CUP // s, Pwc GRAVEL RKIN4 26 BE SERVED BY COMMNI TY INV. 326.45-►NV. 326.60 SYSTEM B-3 CB- =32$. 0 r' 4" PVC SCH-40 HOUSE RIM=328.05 `` ` ; PROP ' o' LAXE SEWER (TYPICAL) �' % 30 TK/CMP INV. 326. 1000 GAL PRECAST CONCRETE SEPTIC TANK (TYPICAL) �' �, n "OE � �g`` 4" PVC SCH 40 EFFLUENT SEWER (TYPICAL)Ic 18 f: EXISTING WASTEWATER SYSTEMS TO / 330 D BE DECOMMISIONED AND 19 ABANDONED TYPICAL --' ?:, 335 APPROXIMATE -LOCATION _OF • Y — I COMMUNITY .WATER SUPPLY c 2 a • 111 6" PVC 3 .9 r 6" PV SDR-35 , GRACE . -/ P ACING _ - EFFLUE SEWER I ` /. ASPHALT, I 0 Z35X LOPE i �2 PARKING 5 27 / c i 33s 29 s GRAVEL 21 / PARKING EF 28 " v v` :� 11.' '' SEWER PVC 326.0. V " , I MH-2 �+ --� v NEW 11,250 GALLON .V. 6 / RIM 331 S v v i3 c SEPTIC TANK PVC 3259 INV -35 6" /G� " / 20 , ,� J �G 6 PV SDR 1.000 GAL SEP71C PVC 325.3 Q Q��� — EFFL NT SEWER TANK TYP. q 0 0 _. v m G Wv I 290 LF, 6' _ •y — —_ _.. INV. 6" ——__— — ' PVC 325.6 — — — — XIST7NG CABIN 15 7t6 BE 8' DIAMETER `PUMP z STA770N, ?71M 331 CONNECT NEW 4", MH-3 ADDED TO EXISTIN COMMUNITY " ; EFFLUENT SEWER ,.. _� RIM �336.5 WASTEWATER SYS M i+ INV 6 ; TO EXISTING 1.6" INV. 6 v l� PVC 325.0 PVC 331.4 czb APPRO MATE LOCATION OF v GRAVITY SEWER I COMMUNITY WATER SUPPLY HILLMAN ROAD I I PROPOSED SEDIMENT ENVIRONMENTAL AREA 1\ �6� \ CONTROL FENCE \ / - / PROPOSED HONEYSUCKL HEDGEROW \ \ 3a5 :FOR VEHICULAR BARRIER PROPOSED 3" OBSE NATION \ \ \ WELL \ GRAVEL PARKIN L , 3 3 I 3S3 3S3FS 33 I , r I i I /I I I � I TENNIS,,COURTS I i APPROXIMA Tq EXISTING I DRAINAGES ALE i 1 EN LEGEND: 6" PVC SDR- 5 v v EFFLUENT SEWER 3 ®1 SLOPE v .' �- v i '10 (3) 2"-PVC SDP-26 FORCE ,MAINS; PROVIDE / 335 5' MINIMUM FROST PROTECTION 12 32 & `INV. 6" / 14 PVC 326.E j i MH=4 / RIM \ %\ 31 = UTILITY POLE _ c = LIGHT POLE ' wv M = WATER VALVE * = WATER SHUTOFF ASPHA PARING I I( I I I I I MAP REFERENCE I I ILIMIT OF CRITICAL ENVIRONMENTAL AREA I BoNS Xo�s� g0A9 FOR COMPLETE SURVEY INFORMATION SEE. "MAP MADE FOR TAKUNDEWIDE" PREPARED BY VAN DUSEN & STEVES LAND SURVEYORS, DATED MARCH 13, 2003, LAST REVISED 101112003. OVERALL SITE PLAN SCALE. 1 "=50' I f I 1 I LIMIT OF CRITICAL \ o SHALLO ABSORPTION FIELD; (10) ll PIPE—IN�STONE TRENCHES 0100 I BOTTOM IOF TRENCH EL.. 350 ! I I I ti APPROXIMATE 1 I EXISTING TREELINE 1 I 1 4 SHALLOW ABSORPTION FIEL ; (10) I 1 1 PIPE -IN -STONE TRENCHES ® 100' I I BOTTOM OF TRENCH EL. 31 9 � I � I , I I SHALLOW ABSORPTION FIELD; i1o) I PIPE —IN —STONE TRENCHES ® 1100- i BOTTOM OF TRENCH EL. 349 I I I LIMIT OF DISTURBANCE I I ' 80,000 SF± �3" OBSERVATION WELL 1 I I I I (3) 2" PVC SDR-26 FORCE MAINS , I I I .'/ I I I 1�1\ i I I I I I APPROXIMATE EXISTING I I I I DRAINAGE SWALE I I 1 I I I � I - I.VW-t I AW1 V iW IV NTS Dig Safely. Now York ■ Call Before You Dig ■ Walt The Required Time ■ CoMlem Ufllity Response ■ Respect The III ■ Ng With Care 300.962-7962 rww.d19-felynswyork.— I I I I 1 I I I I I 1 / / / / I I + I I I I I 1 I I I I + I + I \ 1 � I I , I I I , 1 I I I I I , I I I I 1 I I I I , I I I , I I I I I I I I I 1 I Eadc E 0 6 021 RC-086 )W O QUE NSBURY 239.8-1-44 BUILDING & CODES Paplanus, Lisa 15 Tuscarora Dr 768 s.f Residential Add (2nd floor) TAX PARCEL ID; 240.5-1-13 ALTERATION OF THIS DOCUMENT EXCEPT BY A LICENSED PROFESSIONAL ENGINEER IS A VIOLATION OF NYS EDUCATION LAW.