Loading...
2003-480 TOWN UQUEENSBURY 742 Bay Road,Queensbury,ICY 12804-5902 (518)761-8201 Community Development•Building&Codes (518)761.8256 FOCCUPANr"'�ERTZF zCATE � Permit Number: P20030480 . Date Issued: Wednesday,July 28,2004 This is to cerriif that work requested to be done as shown by Permit Number P20030480 has been completed. Tax Map Number: 523400.290.000.0001-082.016-0000 L Location: 37 STONEHURST Dr Owner: SCOTT TYNON Applicant: SCOTT TYNON This structure may be occupied as a: By Order of Town Board Fireplace TOWN OF QUEENSBURY Garage-2 Cars Attached Single Family Dwelling Director of Building&Code Enforcement Nr TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20030480 Application Number: A20030480 Tax Map No: 523400-290-000-0001-081-016-0000 Permission is hereby granted to: SCOTT TYNON For property located at: STONERURST Dr in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Tune of Construction Value Owner Address: MAINE ENTERPRISES I INC Fireplace 32 TERRACE Ln Garage-2 Cars Attached QUEENSBURY,NY 12804-0000 Single Family Dwelling $220,000.00 Total Value $220,000.00 Contractor or Builder's Name Address Electrical Inspection Agency INSPECTOR, THE 543 EASTLINE Rd BALLSTON SPA,NY,NY 12020 Plans&Specifications 2003-480 LOT 65 HSE#37 STONEHURST DRIVE 2372 SQ FT SINGLE FAMILY DWELLING WITH 2-CAR ATTACHED GARAGE AS PER PLOT PLAN SPECIFICATIONS $329.24 PERMIT FEE PAID-THIS PERMIT EXPIRES: Wednesday,July 14,2004 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at re To . Jofeju eay,July 14,2003 SIGNED BY for the Town of Queensbury. Director of Building&Code Enforcement BLDG. PERMIT NO. 90 APPLICATION FOR A TEMPORARY CERTIFICATE OF OCCUPANCY A TEMPORARY CERTIFICATE-OF OCCUPANCY is hereby requested for the property located at, for the following.uses: DATE SIGNATURE OF APP CANT TEMPORARY CERTIFICATE OF OCCUPANCY . The-TEMPORARY CERTIFICATE OF OCCUPANCY is hereby (1WlAPPROVED ( )DISAPPROVED with the following conditions: Ai"+ t � QtA Pin e TEMPORARY CERTIFICATE OF OCCUPANCY FEE: H 10.00 DEPOSIT:<H$100'.00 received on . Date of issuance Director of Bldg. & Code Enforcement Ti.IIS TEMPORARY CERTIFICATE OF OCCUPANCY,EXPIRES DAYS FROM THE DATE OF ISSUANCE. NOTE: This Certificate is NOT VALID unless signed by the Director of Bldg. & Code Enforcement or his designee. Building Pernut Application Town of Queensbury Department of Community Development,742 Bay Rd., Queensbury,NY 12804 (518)761-8256 " A permit must be obtained before beginning construction. Permit No.: No inspection will be made until applicant has received a Fee Paid: � 3 valid building permit. Form must be completed. Rec.Fee Paid: Reviewed B .;../' gel 711 Applicant: C Owner: 1` t Address: Address: 1 l Phone#: [.j S- 4..� � Tax Map Number: / - - Subdivision Name: (if applicable) 65,..-- Lot Number: /House Number: /Street Name G Q OR - Property Location: New Building: esidential Commercial Estimated Market Value of Construction: C J � ❑ Addition: Resi ential/Commercial If an Addition,what will use of addition be? ❑ Alteration: Residential/Commercial ❑ No change to Exterior size: Residential/Commercial ❑ Other work: (describe ) Check Below Occupancy Info 1"floor sq.ft. 2° floor sq.ft. Other floor sq.ft. Total Sq.Ft. f- Single Family Dwelling '0 3 � Two Family Dwelling E Townhouse UN % S 2�Q3 Multifamily Dwelling QUEE�c�C3l}R`� #of units -rNNN 11 OF ® E Office [,1 1�D1_.C'---�'" Mercantile _-Manufacturing 1 car detached garage r 2 car detached garage 3 car detached garage 1 car attached garage 2 car attached garage 3 car attached garage Storage Bldg.,Comm. i3 Storage Bldg.,Res. Other What is the proposed height of the structure: feet inches Will any second-hand or ungraded lumber be used? If so,for what? /V® No. of Fireplaces to be installed: 7— No. of Woodstoves to be installed: List below the person(s)responsible for supervision of work in regards to Building Codes: Name Address r, Phone No. Builder Q rYc. 4 - Plumber 143 Mason Electrician Declaration: Please sign below after you have carefully read the statement: --- To the best of my .knowledge the statements contained in this application, together'with the plans and specifications submitted,are a true and complete statement of all proposed work to be done on the described premises and that all provisions of the Building Code,the Zoning Ordinance and all other laws pertaining to the proposed work shall be complied with, whether specified or noted, and that such work is authorized by the owner. Further, it is understood that I/we shall submit,prior to a Certificate of Occupancy or Certificate of Compliance being d, as requested by the Zoning Administrator or Director of Building and Codes,an As Built Survey by icensed surveyor; c ra to scale,showing actual location of all new construction. Signature: {circle one: owner wrier's agent,architect,contractor) Application for Permit—Septic Disposal System Town of f Queensbury 742 Bay Road Queensbury,NY 12804 (518) 761-8256' 1. OWNER INFORMATION: .......... ............................................................................... ........................ Office Use Location of installation:7!�:� File Permit N,.0 Tax Map No. Fee Paid Owner's Name: .................................... .................... ................. ...................... Address: 2. INSTALLEW&NAME PHONE NO. 3. RESIDENCE INFORMATION: (circle year of dwelling, indicate#bedroom(s) and multiply#of bedrooms with applicable gallons per bedroom to equal total daily flow) Year of House: No. of Bedrooms x Computation = Total Daily Flow 1980 or older X 150 gal/bdrin 1980- 1991 X 130 gal/bdrm 1991 —present :: 7 X 110 gal/bdrm Garbage Grinder Installed yes no Spa or Hot Tub Installed yes no 4. PARCEL INFORMATION: (circle applicable inforinatibn&indicate measurements) Topography Soil Nature Ground Water Bedrock or Impervious Material Domestic Water Supply Flat sand at what depth at what depth nlu-ie Rolling loam feet —feet well Steep slope clay e ; water supply %slope other from any septic-system depth: absorption is )C>C> other Percolation Test: (To be completed by licensed professional engineer or architect) Rate: minute per inch 5. PROPOSED SYSTEM: For New Construction: All individua ewage disposal systerris must be designcd`bya licensed professional engineer or architect(unless installed in a Planning-Board approved subdivision). Add250 gallons to the size of the septic tank and leach field for each Garbage,Grinder,Spa or Whirlpool Tub. Septic Tank: gallon(min. size 1,000 gal.) f Tile Field: each trench v-� t. Total System Length: Seepage Pit(s): number of size of each: _ft. by_j?. Size of Stone to be used: # depth or thickness feet. Bed System Size: X Alternative System: length andlor size 6. HOLDING TANK SYSTEM: (if required) Number of tanks: Size of each: gallons TOTAL Capacity: gallons Note: Alarm System and associated electrical work must be inspected by a Town approved electrical inspection agency. 7. SIGNATURE &INFORMATION FOR RESPONSIBLE PERSON(please read) For your protection,please note that pursuant to Section 136-29 of the Code of the TovV11 of Queensbury, any permit or approval granted which is based upon or is granted in reliance upon any material misrepresentation or failure to make a material fact or circumstance known by or on behalf of an applicant, shall be void. I have read the regulations with respect to this application and agree to abide by these and all requirements of the of Queensbury Sanitary Sewage Disposal Ordinance. Doe 76ignature of re4)&r— e person Date - � � 'I issv'st•<if (Zt:c:r.�t�tst,ii•y . S (!%VVM ::I1(2 Sewsis;e3 Dbq)t sal (:Itstlslcr . �hlx-talix (: If'IIAil ' SIB:I'11II.A'i`IL)1`�i 'ILI.t2t.Jliti�iLII�:N'I`�; � . Y#t!i M4 �. _ _•. _._ .._ -_.. __ �ttT POwl> V'I[:.LL ttt �thTtz•R- � ` �„/ .fit lt'�t•d 3!P" —7t Mr�YL tpSt 1 ttt•t f A�t!,•trRt"trcti 1 • i`;A.Lfi� 7. SiGNA E &INFOgMAII01i FOIL %vats --..,..w ' Jul 02 03 02: 07p bill herl,ih3 793-2157 -p. l -3co TT t ". d i0 ENERGY CODE CC�►MPLIANCE'..AA P,PLICA',, TOWN OF QUEENSBTJ.R.'Y", WARREN COUNTY 0000 BEATING DEGREE DAYS Part S -Acce table Practice 3Ylethod-- 18c2 Family DwelXinly Compliance Methods.• ) . p Part 6* Thermal Rating-Component trade Offs 1&2 Family Dwilin Multi-Family Dwellings.(3 Stories or,less}rmance,Cozzimercial B � ��Part 4*--Design by'Component PerfoND COS - Rise Residential ��1 *Requires submission- f,worksheets APPLICANT'S NAME: PROPERTY--LOCATION: PART S METHOD OF COMPLIANCE BY ACCEPTABLE PRA�+ iOC3 6�[+!!f`i1 feet WE �-p ii aT 1. Gross.Floor Area-- - 0:3 7a square _ 2 _ Type of heat'- Electric Oil as Other 3.. Is building mechanically cooled? yes 4: Percentage.of area of windows-and doors /Over 17% Under 17%n R VALUES FOR INSULATION GIVEN BELOW MUST CORRESPOND,TO R VALUES AS 5. SHOWN ON PLANS SUBMITTED:' a., Roof '-_ .. r, Rom_. b. Exterior walls R. c. Glazed areas R .-31 d. Exterior doors R=- = e, Floors over unheated spaces R_ - f. Edge of slab on grade(heated building) R. g. Basementicellar walls(above grade) R�Sf� R [ h. Basement1cellar wads(below grade) J i, Heating/cooling-ducts-piping in iunheated'space R 6, Service (domestic)hot water heating device Conforms to minimum efficiency per code 9C Yes No TEMPERATURE CONTROL MAXIMUM SETTING 140--WILL NOT BE EXEEDED Appl' is Sig at Dat - Phone Number sib INSPECTOR'S REMARKS': Fare Marshal's Office . Town of Queensbury,742.Bay Road,Queensbury,NY (518)761-8205 Application for Fuel Burning Appliances-& Chimneys applicable to solid fuel& vented gas appliances Date 20 Petrait No.� a Application is hereby made to the Building& Codes Officefor the issuance of a Building and Use Permit pursuant to'the.New York State Fire Prevention and Building Code. The applicant or owner agrees to c`oniply with all applicable laws, ordinances, regulations, crud all conditions that are part of, these requirements and also will allow all inspectors to enter preinises.10 per form required.inspections. NOTE to applicant: Rough-in and Final Inspections are required. Applicant Information Fuel Burning Appliance Information (circle appropriate words) Name: ca Stove: wood coal' pellet gas : � ."" ``�t �) :Fireplace insert Address t 1.`..) rc` ,4. f` Fireplace, factory woodgasD__ Fireplace,,masonry wood - gas 4-0- Furnace: wood .gets oil Phone: s If non-masonary applicance,please provide Owner• l is Manufacturer Name. Address: Model Number Chimney Information Phone: (circle appropriate words) Masonry block brick stone Flue tile steel size inches Exact Address: F` 7 :nm ; of eonstrucdon o'r,insiallatirrrr Factory-Bitilti +` "" Manufacturer name: Model Number Note: Listed.By: Number: _. Construction Ilnstallation must con orrn to NYS Fire Prevention &Building llidieate(circle) chimney material: Code. Consult available Town of Queensbut), Handouts regarding required inspections. Double ivall / Triple wall % Insulated / Direct.venting Chimney Linei l Ca.���zr'rr3 Dep�-ts�e�t—2'©�� 'of Queen�buz-y, At®�Yoram: f Fire Marshal Corte#1 S Collected $Rq�funded Received fi-orn (refunded,to):�1� �� � � - 0 address.--_ r_ A 173 338.9 (190) Public Safety A 233 2655 (230),Minor Sales C �y, White(Applicant) 1 Green(tire Marshal) f Yellow(Bldg.Dept.) ! Pink&Goldenrod(Cashier's.Dept.) O QueensburY Building & Code Enforcement - Residential Final Inspection Arrive: —am/pV epart q �aam/pmoffice No�(518)761-8256 Inspector's Initials: Date inspection request received: PERMIT#: R NAME: DATE: 0 Ll LOCATION: I TYPE OF STR ZEUCTI- S-D Comments Y N NIA B 13"Vent/Direct Vent Location D Chimney-hake- -- Q ake 019 , , F T V� Tesh mb Vent through roof minimum 6" 3 i in�o`mplete Exterior Finish CoLnpfete �aW @ d 30 in,or more stairs,decks,patios rd at stairwell at 34 in, or more 'Guard at deck,porches 3 6 in. or more / Exterior Finish Complete Interior/Exterior Railings 34 in.to 38 in. Platform at all exterior doors Interior Handrails stairs 2 or more risers Enclosed Stairs Sheetrock Underside minimum V2*' Gypsum Grade away from foundation 6 in.with 10 ft. Handrail Termination at Newell Post or Wall 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18"above grade Gas Furnace shut-off within 30 ft. or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp I 10 Interior privacy/trim/doors/main entrance 36 in. Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: / Every Bedroom: Outside every bedroom area: Inter Connected: - / Battery backup: Carbon Monoxide Detector Bathroom Fans, if no window Plumbing fixtures Foundation insulation ooftruss,draft stop2ing finished basement 1,000 sf mergency egress below grade Basement stairs closed rise>4 inches G, Garage Floor Pitched Garage fireproofing hour fire door/door closer Duct work Seated properly Gas Logs in Sealed or Glass Enclosure Attic access 30 in.x 22 in.x 30 in.(ht,)In accessible area Crawl Spaces 18"x 24"access, I sq. f1.-150 sq. ft.vents Building No./Address visible from road Final Electrical Site Plan /Variance required Final Survey Plot Plan As Built Septic System/Sewer Dept.Ins pegliptrtST0:g Flood Plain Certification., if required Okay to issue C/C or C., 0 [Temporar 1 Permanent L:\Parn.W\Building&Codes\Insvection Formse�sFinal Ing). form 2.docLast vrinted 2/12/04 Queensbury Building & Code'Enforcement - Residential Final Inspection Office No. (518)761-8256 Arrive: _am/pm Depart: am/pm Date Inspection request received: Inspector's Initials: NAME: PERMIT#: LOCATION: DATE: -7 4q10,V TYPE OF STRUCTURE: Comments Y N N/A Chimney Ht./"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumb Vent through roof minimum 6" Roof Complete/Exterior Finish CoLnplete Guard 30 in. or more @ stairs,decks,patios Guard at stairwell at 34 in. or more Guard at deck, orches 36 in. or more Exterior Finish Complete 'Interior/Exterior Railings 34 in.to 38 in. Platform at all exterior doors Interior Handrails stairs 2 or more risers Enclosed Stairs Sheetrock Underside minimum 1/2" Gypsum Grade away from foundation 6 in.with 10 ft. Handrail Termination at Newell Post or Wall 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18"above grade Gas Furnace shut-off within 30 ft. or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s) installed/Heat Trap/Water Temp 110 Interior privacy/trim/doors/main entrance 36 in. Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: _ / Every Bedroom: Outside every bedroom area: Inter Connected: — / Batted b ckup: Carbon Monoxide Detector Bathroom Fans,if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sf Emergency egress below grade Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/3/4hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Attic access 30 in,x 22 in.x 30 in.(ht.)In accessible area Crawl Spaces 18"x 24"access, I sq.ft.-150 sq. ft.vents B iilding No./Address visible from road Final Electrical Site Plan /Variance required Final Survey Plot Plan As Built Septic System/Sewer Dept. Inspection Sticker Flood Plain Certification, if required Okay to issue iC/C or C/0[Temporary/Permanent L:\PamW\Building&Codes\lnsi)ection Forms\Res.Final Insn. form 2.docLast minted 2/12/04 Town of Queensbury Fire Marshal tJ 742 Bay Road Queensbury,NY 12804 761-8205/761-8206 �� fax 7454437 Factory Built Gas Fireplace/Stove In�sgection_Report_ Notice:New York State requires that all UL Listed,factory built appliances be installed according to the instructions and specifications contained in the Installation Manual accompanying the appliance.No deviation from;the manufacturer's instructions o sp *H ations is allowed, ' Permit# oat V Schedule InspectionTime✓ am pm anytime Inspector Name .5&O f;r%N�QA1 Address n Y4 �c f Rough Finale Appliance Manufacturer. Pwtv Model# 6 U0 LT-Z—.� Direct Vent Factory Built Chimney Fine Size Double Wall Triple Wall Insulated Yes No N/A Comments Floor Protection Clearances to Combustibles (all sides) Ficestop(s) Vertical Chase Wall Penetration Vent Clearances to Combustibles �-. /���,a �1 G Vent/Chimney Termination � Chimney height must be 3 feet above roof p � �� � heA ��„�/.�r�f penetration;2 feet above any combustible C construction within 10 feet Gas Shut-off Valve Combustion Air Hearth Extension(if any) Mantel Height above flp opening Witness Operation Tank Placement(if LP) White--Bu Ning Dept. -- Yellow er Pink—Fire Marshal Town of Queensbury Fire Marshal ` 742 Bay Road Queensbury,NY 12804 761-8205 1761-8266 1 fax 7454437 Factory Built Gas Fire lace 1 Stove 1ais ection Re ort Notice:New York State requires that all UL Listed,factory built appliances be installed according to the instructions and specifications contained in the Installation Manual accompanying the appliance.No deviation from the manufacturer's instructions or sp ci cations is allowed. Permit# d� '- ( � Schedule Inspection �71t Time am' pm anytime Inspector �s Name tJv� 6d Address � l�ti z Rough In___,FinaIX", Appliance Manufacturer Model# . Direct Vent Factory.Built Chimney Flue Size Double Wall Triple Wall Insulated— Yes No N/A Comments Floor Protection. Clearances to Combustibles wall skies) Firestop(s) Vertical Chase Wall Penetration Vent Clearances to Combustibles V l Vent/Chimney Termination Chimney height mush be 3 feet above roof penetration,2 feet above any combustible . ! construction within 10 feet ) Gas Shut-Off Valve Combustion Air [earth Extension(if any) a5e Mantel. Height above f/p opening Witness Operation i i Tank Placement(if LP) White—Building Dept. Yellow er Pink—Fire Marshal '2"g & o re 1:1fb ia 7Final r1nsp=WL&" Queensbury Building Office No. (518)761-8256 Arrive: am/ m Depart:, am/pm Date Inspection request received: Inspector's Initials: NAME: h PERMIT#: 100_ -q-,20 LOCATION: 11� JULAAJI UJY—Vi-- DATE: 00 TYPE OF STRUCTURE: �i Piz) Comments Y N N/A CIO Chimney Ht./"B"Vent/Direct Vent Location Fresh Air Intake 3 inch PlumbVent through roof minimum 6" Roof Complete/Exterior Finish CoLnplete Guard 30 in.or more @ stairs,decks patios t24q % Guard at stairwell at 34 in. or more Guard at deck,porches 36 in.or more Exterior Finish Complete Interior/Exterior Railings 34 in.to 38 in. Platform at all exterior doors 'i CILAZ`ld�l Mf5-0&A4'f-'f Interior Handrails stairs 2 or more risers Enclosed Stairs Sheetrock Underside minimum V2" Gypsum Grade away from foundation 6 in.with 10 ft. Handrail Termination at Newell Post or Wall 6 inch clearance to sill plate Gas Valve shut-off ex2osed/regulator 18"abo�vejgKade Gas Furnace shut-off within 30 ft. or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s) installed/Heat Trap/Water Temp 110 Interior privacy/trim/doors/main entrance 36 in. Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: — / Every Bedroom: Outside every bedroom area: Inter Connected: 1 Battery backup: Carbon Monoxide Detector Bathroom Fans, if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sf Emergency egress below grade Basement stairs closed rise>4 inches Gara e Floor Pitched Garage fireproofing/'/4 hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Attic access 30 in.x 22 in.x 30 in.(ht.)In accessible area Crawl Spaces 18"x 24"access, I sq. ft.-150 sq.ft.vents Building No./Address visible from road Final Electrical Site Plan /Variance required Final Survey Plot Plan As Built Septic System/.a_ewer P�0—pfj%§pection Sticker Flood Plain Certificatiq6,1f-1V,4uired- I Oka yto issue C/CorC/0 Tempora /Permanent I U j �6 In c *L:\PamW\Building&Codes\Ln FOrn15\ReS.Final Inst). form 2.docLast printed 2/12/04 Queensbury Building & Code Enforcement - Residential Final Inspection r Office No.(518)761-8256 Arrive: am/ Depart: am/pm Date Inspection request received: Inspector's Initials: 111(4 a-5-opm- 14�7 NAME: )A� PERMIT LOCATION: 31 iiA DATE: 00 &n-- TYPE OF STRUCTUAE: Fb Comments N N/A Chimney Ht./"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumb Vent through roof minimum 6" ,goof Complete/Exterior Finish Co nplete IV"Guard 30 in.or more @ stairs,decks,patios Guard at stairwell at 34 in. or more Guard at deck,porches 36 in.or more ,Exterior Finish Complete Interior/Exterior Railings 34 in. to 38 in. Platform at all exterior doors Interior Handrails stairs 2 or more risers Enclosed Stairs Sheetrock Underside minimum 1/2" . ypsum V Grade away from foundation 6 in,with 10 ft. Handrail Termination at Newell Post or Wall 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18"above grade Gas Furnace shut-off within 30 ft. or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating lAli-rh&—1�U d— WADIA!'�� Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 110 Interior privacy/trim/doors/main entrance 36 in.. /Bathroom/Kitchen watertight AAS• 5A:M Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: 4Y- /Ve Every level: — I Every Bedroom: Outside every bedroom area: Inter Connected: — / Battery backup: Carbon Monoxide Detector A Bathroom Fans,if no window j ,Plumbing fixtures V 0, V'Foundation insulation Ai IAc;�ed Floor truss,draft stopping finished basement 1,000 sf p iA Emergency egress below grade 18 NSA V P,6,. Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/1/4hour fire door/door closer Duct work Sealed properly Act, Gas Logs in Sealed or Glass Enclosure Attic access 30 in.x 22 in.x 30 in.(ht.)In accessible area Qrawl Spaces 18"x 24"a9cess, I sq. ft.-150 sq. ft.vents ,(Building No./Addrgss v/,5jbV fro jn road Final Electrical (le 1 15 ow 74— /Site Plan /Variance ikqiTi d V Final Survey Plot Plan As Built Septic Sy stem/Sewer Dept.Inspection Sticker Flood Plain Certification,if required A Okay to issue C/C or C/Cl[Temporary/Permanent V I L:\PamW\Building&Codes\lnsvection Forms\Res. Final Insi).form 2.docLast winted 2/12/04 Queensbuly Building & Code Enforcement - Residential Final Inspection . t Office No.(518)761-8256 Arrive: am/p" e'pa am/pm Date Inspection request received: Inspector's Initials: NAME: `i�'�ll � PERMIT#: C '"#6 LOCATION: DATE: TYPE OF STRUCTURE: Comments Y N N/A Chimney Ht./"B"Vent/Direct Vent LocationLL Fresh Air Intake 3 inch Plumb Vent through roof minimum 6" Roof Complete/Exterior Finish Complete Guard 30 in.or more cry stairs,decks,patios Guard at stairwell at 34 in. or more Guard at deck,porches 36 in.or more Exterior Finish Complete Interior/Exterior Railings 34 in.to 38 in. Platform at all exterior doors - Interior Handrails stairs 2 or more risers Enclosed Stairs Sheetrock Underside minimum %"Gypsum _ Grade away from foundation 6 in, with 10 ft. Handrail Termination at Newell Post or Wall 41 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18"above grade Gas Furnace shut-off within 30 ft. or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp, 110 Interior privacy/trim/doors/main entrance 36 in. Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing1,J Interior Smoke Detectors: rj Every level: / Every Bedroom: Qv�r 66 Outside every bedroom area: Inter Connected: / Battery backup: Carbon Monoxide Detector Bathroom Fans, if no window Plumbing fixtures n Foundation insulation Floor truss,draft stopping finished basement 1,000 sf Emergency egress below grade y� Basement stairs closed rise>4 inchesOS�� Garage Floor Pitched 01 Garage fireproofing/3/4 hour fire door/door closer V1, Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Attic access 30 in.x 22 in.x 30 in.(bt.)In accessible area Crawl Spaces 18"x 24"acce s, Y s . ft.-150 s .ft.vents Building No./Address vi ib f road Final Electrical Site Plan /Variance re uir Final Survey Plot Plan VN�rG-^ 7U�VU� As Built Septic System/Sewer Dept. Inspection Sticker Flood Plain Certification, if required Okay to issue C/C or C/0 Temporary/Permanent] L:\PamW\Building&Codes\Insvection Forms\Res.Final Inst3. form 2.docLast printed 2/12/04 Town of Queensbury Fire Marshal 742 Bay Road Queensbury,NY 12804 761-8205/761-8206 t fax 7454437 Factory Built Gas Eireplace/Stove insuection Reuort Notice,New York State requires that all UL Listed,factory built appliances be installed according to the instructions and specifications contained in the Installation Manual accompanying the appliance.No deviation from the manufacturer's instructions or specifications is allowed. Permit# t 00 /10�v Schedule Inspection 1 Time aMloanytime Inspector Name �i} ��j Address J� ___ Dough In�I+ nal.,X__ Appliance Manufacturer—K -t? Model# Direct Vent Factory Built Can haney Flue Size Double Wall- Triple Wall Insulated Yes No N/A Comments Floor Protection l�01 - " � 0 Clearances to Combustibles (all sides) i Firestop(s) Vertical Chase Wall Penetrat. Vent Clearances to Combustibles Vent/Chimney Termination Chimney height must be 3 feet alcove roof penetration;2 feet above may combustible construction within 10 feet Y, Gas Shut-Off Valve Combustion Air Hearth Extension if any) I Lx Mantel Height above f/p opening Witness Operation Tank Placement(if LP) White—BuihaingDept. � 'yellow Cas er Pink—Fire Manhoi � e i} f Town of Queensbury Fire Marshal 742'Bay Load Queensbury,NY 12804 n a ,��1 4a,i If 761-8205/761-8206 �i/ LVN fax 745-4437 Factory Built Gas Fireplace/Stove In,siDection Report Notice:New York State requires that all UL Listed,factory built appliances be installed according to the instructions and spec cations contained in the Installation Manual accompanying the appliance.No deviation from the manufacturer's instructions or s ec' cations is allowed.. `V/� Permit# y Schedule Inspection Time � L� arcs pan ytinxe �Gcaspeetor 22 Name ` " Address i7 D� Rough In __ Final, Appliance Manufacturer 'Model# F-,%2(n —LF i Direct Vent Factory Built Chamaley .Flue Size ? r� Double Wall Triple Wall Insulated Yes No N/A Comments Floor Protection Clearances to Combustibles (all sides) ✓ 0 el Ftrestop(s) Vertical ChaseX, Wall Penetration Vent Clearances to Combustibles v od (� -Qm&l eA - aA /-S ou c. te a Vent/Chimney Termination • Chimney height merit be 3 feet above roof penetration;2 feet above may combustible construction within 10 feet tbo Gas Shut-Off Valve x Combustion Air Dearth Extension if any) .4kA Mantel � �- Height above f/p opening Witness Operation Tank Placement{if LP) White—Duitaling Dept. ellow Cleat er Pink—Fire Marshal Septic Inspection Report Office No. (518)761-8256 Date Inspection request received- Queensbury Building&Code Enforcement 'Arrive: arn�/p rLepart- am/pm 742 Bay Rd.,Queen�s­bury,NY 12804 Inspector's Initial NAME: /Ae".) PERMIT NO.: LOCATION: 61-0 �o INSPECT ON: RECHECK: Comments and/or diagram Soil Type: nd L Cl Type of Water: Municipal(Well Water Waterline separation distan Well separation distance ft, Other,wells: ft. Absorption Field: Total length ft. Length of each trenches ft.- Depth of trenches ft. Size of Stone Zi- See Pits: Number Size: x Stone Size: Piping Size Building to tank tj00 Tank to Distribution$ox a 7� Distribution Boy/,fo- Fi ld Pit Opening Sealej: Y/&/Partial Location/Separations Foundation to tank ft. Foundation to absorption ft. Separation of Pits ft. I Conforms as per Plot Plan --"'Y N o� A )641a'r Location of System on Property. )Front(Re oLe� Side Right Side Middle Front Middle Rear System Use 4Statu Approved Partial Approved and needs to be re-inspected,please call the*Building&Codes Office Di8approved L:\SueHemingway\Building.Codes.Inspection.FORMS\Septic Inspection Report.dw January 28,2003 , +L n r F have seen or observed or �jP 'Rt� all oblints sulch as huou r �!„�v I.S�S, Creel S ^t.N.r} l thisCi1C1! i}cn . also r2:.).?SE uersonal1y " I red tflie distances set SIGNAT a 15' Y j 1 L�R,�ya 'o(psL I PROPOSED �L9 �C� WELL A - PROPOSED 0 g2.Q. HOUSE p�fie kW CL - { � !�1 as In 15' c 350.53' N86037'30"W MAP REFERENCE: 00 MAP OF SECTION TWO O 5TONEHUR5T A SUBDIVISION DEVELOPED BY CHARLES + BEVERLY MAINE DATED, JULY 2g. 1gB7 I AAT RFVI4Fni .IANI IARY 95_ 1clq-9 Framing /Firestopping Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/p 4f tP ani(pm ! ft !_T_V 742 Bay Road,Queensbuiy,NY 1.2804 Inspector's Initials NAME: PERMIT#: 6 LOCATION: Z)P-� INSPECT ON: 6f TYPE OF STRUCTURE: Y N N/A Framing COMMENTS Jack Studs I Headers Bracing Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 V2(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1,2,3 hour wall 2,3,4 hour t Firestopping Penetration scaled 16 inch insulation in cavity min, Garage Fire Separation House side Y2inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade LAS=Hemingway\Building.Codes.InspectionTORMSTraming Firestopping Inspection Report.doo January 28,2003 Rough Plumbing/Insulation Inspection Report Office No. (518)761-8256 Date Inspection request received: j Queensbury Building&Code Enforcement Arrive:-am/dpLart: M 742 Bay Road,Queensbury,NY 12804 Inspector's Initials: NAME: PERMIT#: 0;3 A 4 LOCATION: INSPECT ON: ";K-. TYPE OF STRUCTURE: N N/A PVC:. R-1,R-2,R-3,R-4 Drain Vents Cast Iron,Copper Drain/Vent Comm. Plumbing Vent Vents in Place Rough Plumbing/Nail Plates FN P-..�-k A- Head or Air Supply Test Drain and Vents 5 PSI or 10 ft. above ove highest Connection for 15 minutes Water Supply Piping -6 pper Commercial tK)A,u—c�,Copper,CPVC,Pex One&Two Family C Insulation/Residential Check/Commercial Check -Proper Vent,Attic Vent Duct/Hot Water Piping insulation If required unheated spaces Combustion Air Supply for Furnace Duct Work Sealed Properly COMMENTS: :L:\SueHemingway\Building.Codes.Inspection.FORMS\Rotigh Plumbing Insulation Report.doc January 28,2003 Rough Plumbing./ Insulation Inspection Report Office No. (518)761-8256 Date Inspection request received: Queensbury Building&Cade Enforcement Arrive: am/p D part: am/p 742 Bay Road, Queensbury,NY 12804 Inspector's Initials:�� NAME: Gy `t _ _ _ PERMIT#: 003� .�� 1-0 LOCATION: 7G"r. ``tc v S '% INSPECT ON: TYPE OF STRUCTURE: Y N N/A PVC: R-1,R-2,R.-3,R-4 Drain/Vents Cast Iron,Copper Drain/Vent/Comm. Plumbing Vent 1 Vents in Place Rough Plumbing/Nail Plates Head or Air Supply Test Drain and Vents 5 PSI or 10 ft. above highest Connection for 15 minutes Water Supply Piping PP Y p g Copper Commercial P66 VO,04 Copper, CPVC,Pex One &Two Family Asulati :/.Residential Cheek/Commercial Check F �, 601 • Proper Vent,Attic Vent Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace uct Work Sealed Properly CCIl!E TENTS: L:\SueHemingway\Building.Codes.Inspection.FORMS\Rough Plumbing Insulation Report.doc January 28,2003 Rough Plumbing/Insulation Inspection Report Office No. (518)761-8256 Date Inspection reques received: , ar Queensbury Building&Code Enforcement Arrive: am/pm We a� , 4 4-6&Pm 742 Bay Road,Queensbury,NY 12804 Inspector's Initials:"�'- C 22��G " - z74�?D NAME: PERMIT#: j LOCATION:. UAA INSPECT ON: TYPE OF STRUCTURE: N N/A PVC: R-1,R-2,R-3,R-4 Drain Vents Cast Iron,Copper Drain/Vent Comm. Plumbing Vent/Vents in Place Rough Plumbing/Nail Plates Head or Air Supply Test Dfain and Vents 5 PSI or 10 ft. above highest Connection for 15 minutes Water Supply Piping Co er Commercial --,4(gper,CPVC,Pex One&Two Family Xs 1�4(:Lnj Residential Check/Commercial Check V,/ 2, Proper Vent,AttiOVent V/ L(A)(— Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace et Work Sealed Properly CONIMENTS: L:\SueHbmingNvay\Building.Codes.Inspection.FORMS\Rough Plumbing Insulation Report.doc January 28,2003 Framing/Firestopping Inspection Report 7—/6/k Office No. (518)761-8256 Date Inspection request received- Queensbury Building&Code Enforcement Arrive: am/��epa am/pm 742 Bay Road,Queensbury,NY 12804 Inspector's Initials: NAME: PERMIT#: LOCATION: INSPECT ON: TYPE OF STRUCTURE: ng Y N NIA COMMENTS 27mi Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 V2(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2,3 hour 'Fire a11.2, 3,4 hour stopping A4— /4 Penetration sealed 16 inch insulation in cavity min, Garage Fire Separation House side Y2 inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in.(H) 20 in. (W) 5,7 sf above/below grade 5.0 sf grade L:\SueHemingway\Building.Codes.Inspection.FORMS\FramingFirestopping Inspection Report.doc January 28,2003 Rough Plumbing/Insulation Inspection Report Office No. (518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: rrvp part: am/prn 742 Bay Road,Queensbury,NY, 12804 Inspector's Initials. NAME: 0,11-r PERMIT#: LOCATION: INSPECT ON: TYPE OF STRUCTURE: Y N N/A PVC: R-1,R-2,R-3,R-4 Drain Vents Cast Iron,Copper Drain/Vent COMM. Pi bing Vent Vents in Place ough Plumbing/Nail Plates Head or Air Supply Test Dfain and Vents 5 PSI or 10 ft. above highest Connection for 15 minutes &ater Supply Piping Copper Commercial er, VC,Pex One&Two Family Q�sulati esidential Cheek/Commercial Check Proper Vent,Attic Vent Duct/Hot Water Piping insulation If required unheated spaces Combustion Air Supply for Furnace Duct Work Sealed Properly COMMENTS: -L-.\Sueliemingway\Building.Codes.Inspection.FORMS\Rough Plumbing Insulation Report.doc January 28,2003 Framing/Firestopping Inspection Report Office No. (518)761-8256 Date Inspection request received.,*'l Z_ Queensbury Building&Code Enforcement Arrive: aIn/p D paro;� ---�Iam/pm 742 Bay Road, Queensbury,NY 1.2804 Inspector's Initials: NAME: PERMIT#: LOCATION: INSPECT ON: TYPE OF STRUCTURE: Sz Framing Y N N/A COMMENTS Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 3 6 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate I V2(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center and snAshi6d 24 inches from wall nx-.C Fire separation 1,2,3 hour Fire wall.2, 3,4 hour Firestopping Penetration scaled 16 inch insulation in cavity min. Garage Fire Separation House side Y2inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) . 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\SueHemingway\Building,Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doe January 28,2003 Framing /Firestopping Inspection Report Office No. (518)761-825 6 Date Inspection request received- Queensbury Building&Code Enforcement Arrive: am/ art-S—�'�M/pm _ 742 Bay Road, Queensbury,NY 12804 Inspector's Initial NAME: PERMIT#: LOCATION: INSPECT ON: Q 42 TYPE OF STRUCT z Y N N/A COMMENTS Framing Jack Studs/Headers Bracing/Bridging Iv&tt3- Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 V2,(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft, floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1, 2,3 hour Fire wall.2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side V2inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\SueHemingway\Building.Codes,lnspectioTi.FORMS\FramingFirestopping Inspection Repbrt.doc January 28,2003 0 AJ 304CIZ r`) Foundation Inspection Report Office No. (518)761-8256 Date Inspection reques -receiv Queensbury Building&Code Enforcement Arrive: am/p6 Depart: am/pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: -- 4 ' NAME. PERMIT#: ~-' LOCATION: a INSPECT ON: 4 TYPE OIi'STR URE: � Comments Y N . N/A el�ootings Piers Monolithic Slab Reinforcementin Place The contractor is responsible r providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump_ Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:1Sueliemingway\Building.Codes.Inspection.FORMS\Foundation Inspection Reporkdoe January 28,2003 " s Foundation Inspection Report Office No. (518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/pI#/L( Depart: pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: ��J NAME: ��` ' PERMIT#: LOCATION: 5i INSPECT ON: -1 ' C3 TYPE OF STRUCTURE: Comments Y N/A outings Piers Monolithic Slab Reinforcement in Place 2 The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width . 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\,SucHemingway\Building.Codes.Inspection.FORMS\Foundation Inspection Report.doc January 28,2003 Foundation Inspection Report Office No. (518)761-8256 Date Inspection request eceived: Queensbury Building&Code Enforcement Arrive: am/p D part: pm 742 Bay Rd., Queensbuly,NY 12804 Inspector's Initials: NAME: 10 4� PERMIT#: - 0 LOCATION: INSPECT ON: v ` TYPE OF STRUCTURE: Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing r Mooting Drain Daylight or Sump. Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under SIab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:1SueHemingway\Building.Codes.Inspection.FORMS\Foundation Inspection Report.doc January 28,2003 Foundation Inspection Report Office No. (5 8)761-8256 Date Inspection request received: fo ct Queensbury ilding&Cod NY 128 rO.4 forcement Arrive:Inspector's Initialve: am/ Depart. �� m/pm 742 Bay Rd., Qu s NAME: J- PERMIT#: LOCATION:h%V L INSPECT ON: 03 TYPE OF sTkTcTuRE-. ' Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump. I Y Footing Drain Stone:-� I i4ftekAw4�� V 6 inches above footing 6 mil of for wet areas nder slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior Exterior R- Rough Grade 6 inch drop within 10 ft. L:\SueHemingway\Btiilding.Codes.Inspection.FDRMS\Foundation Inspection Report doc January 28,2003 Foundation Inspection Report Office No. (518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/-PAi Depart: -;`ar@pm. 74213ay Rd., Queensbury,NY 12804 Inspector's Initials: S YAL", NAME: PERMIT#: 03- L Fo LOCATION: 3:j INSPECT ON: TYPE OF STRUCTURE: Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Foundation Dampproofing F —tion> a,,-,I /Waterproofing Itype of Dampproofing/Waterproofing Footin rain Daylight or Sump. --TZ-inch width 6 inches above footfing 1/6 mil of for wet areas under slab Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Suellemingway\Building.Codes.Inspectioii.FORMS\Foundation Inspection Report.doc January 28,2003 AA4 a 36 Foundation Inspection Report Office No. (518)761-8256 Date Inspection request received: o /uu Queensbury Building&Code Enforcement Arrive: am/p Depart: : m/pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: NAME: JC 1 r.o PERMIT#: q 6b 3-q o6 LOCATION: kC INSPECT ON: TYPE OF STRUCTURE: Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials LLhis_2urpose on site. undatMn/Wallpour ' Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior 1 Exterior R- Rough Grade 6 inch drop within 10 ft. L:1SueHemingway\BuiIding.Codes.Inspection.FORMS\Foundation Inspection Report.doc January 28,2003 Foundation Inspection Report Office No. (518)761-8256 Date Inspection request received: , Queensbury Building&Code Enforcement Arrive: am/pr > f/Depart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: -1+"-� NAME: PERMIT#: n ,— LOCATION: o INSPECT ON: - — TYPE OF STRUCTURE: Comments Y N/A ootings Piers Monolithic Slab Reinforcement in Place i The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump. Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\SueHemingway\Building.Codes.Inspection.FORMS\Foundation Inspection Report.doc January 28,2003 JohSlic Address: Date: Owner Application No, File No, Building Permit — Calculation Sheet Natural Light, Ventilation & Emergency Egress Requirements r Habitable Area of Req.Light Actual Req,Vent Actual Sq.Ft, Remarks R00111 Room 8%of Room Light 4%of Room Vent Opuing for in Area Square Area Square Egress Square Footage Footage Fee( PA I)A .9 Ir S O'g q. Z 1 54' 201 fl, 0d I 1 17 Check Residential Plan Review: One&Two Family Dwellings Y/N/N/A (2)Full sets of plans Over 1,500 sq. ft.—Stamped Design Loads On Plans: 90 Wind Floor Loads 40 psf 70 Ground Snow Load Sleeping Areas and Attics 30 psf Calculations: Window Schedule With Glass Size Door Schedule/Main Entrance 36"Door Emergency Escape Or Bedrooms and Habitable Space Above/Below grade, 5.7 sq.ft. Grade,5.0 sq. ft. 24"(h)x 20"(w)min. 44"Max.Hei t above floor Residential Check Paperwork Compliance and Inspectors Checklist: OK Dampproofing/W�erproofing Materials Chi Plans Foundation Drainage On Plans,if required 6"Drop in 10' Exterior Grade Framing Cross Section For Each Roof Line,Vertical Fire Stopping Every 10'Where Required Ice and Snow shield 24"Inside Exterior Wall/24"Inside Knee Walls Platforms At Exterior Doors Stairway Headroom 6' 8' All Stairs 36"Width Stair Run and Rise Winder Run and Rise Spiral Not Allowed From 2n Story Ny Smoke Detectors Battery Backup and Proper Location Bathroom Fixtures Proper Clearance Hall Width,36"min. Handrails More Than One Riser On Open Sides Railing and Guards>30"/Basement Stairs Included/Closed Risers More Than 4"in Ht. Safety Glazing Notes For Required Areas Garage Fire Separation Garage Floor Sloped Attic Access Roof over 30"—22"x 30"/Crawl Spaces 18"x 24"Access Carbon Monoxide Detector Lowest Sleeping Level Soil Test Results, if required Septic To Well Or Water Line Separation All Paperwork Signed Town of Queensbury 742 Bay Road, Queensbury, NY 12804' lRuMing & Code Enforcement Building Permit# Phone:(518)761-8256 Date: Fax: (518)745-4437 Email: codes@qucensbury.nct Dear ' Your building permit application:has been reviewed and found to be deficient in the following areas: 4 r . ttd r These details need to be added to or noted on both sets of plans. Please feef five to contact this office with any eons regarding this 3natter. sincerely, BLTIL,DING&CODES OFFICE 4 L:NSucHemingwaytBuilding.Parr itFORMStdelicient building permithu 2003•aoe Parftt NofiDer MECcheck Compliance Report Ch d By/Date New York State Energy Conservation Construction Codf MECcheck Software Version 3.3 Release lc Data filename: C:\Program FiIes\Check\WCcheck\SCOTT TYNON.cck TITLE: STONEHURST LOT 65 RECEIVED COUNTY:Warren JUN 7. 6 Z003 STATE:New York HDD:7635 QUEENSBURY CONSTRUCTION TYPE:Detached I or 2 Family 'TOWN OF HEATING TYPE:Non Electric DING AND CO1)E DATE:06117103 DATE OF PLANS: 6-8-2003 PROJECT INFORMATION: SCOTT TYNON COMPLIANCE:Passes- Maximum UA=928 Your Home=647 30.3%Better Than Code Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA Ceiling 1:Flat Ceiling or Scissor Truss 1352 38.0 0.0 41 Wall 2:Wood Frame, 16"o.c. 6384 19.0 0.0 351 Window 1:Wood Frame,Double Pane with Low-E 519 0.340 176 Door 1: Solid 20 0.070 1 Basement Wall 1: Solid Concrete or Masonry,8.0'ht17.0'bg/8.0'insuI 1040 13.0 0.0 61 Basement Wall 2:Wood Frame,8.0'ht/0.0'bg18-0'insuI 272 19.0 0.0 17 Boiler 1:Other(Exept Gas-Fired Steam),87 AFLJE COMPLIANCE STATEMENT: The proposed building represented in this document is consistent with the building plans,specifications,and other calculations submitted with this permit application. The proposed systems have been designed to meet the New York State Energy Conservation Construction Code requirements. When a Registered Design Professional has stamped and signed this page,they are attesting that to the best of his/her knowledge,belief and bessional judgmerf,sucb plfins or specifications are in compliance with this Code. Builder/Designer Date MECcheck Inspection Checklist New York State Energy Conservation Construction Code MECcheck Software Version 33 Release le DATE:06/17/03 TITLE: STONEHURST LOT 65 Bldg. Dept. Use Ceilings: 1. Ceiling 1:Flat Ceiling or Scissor Truss,R-38.0 cavity insulation Comments: Above-Grade Walls: 1. Wall 2:Wood Frame, 16"o.c.,R-19.0 cavity insulation Comments: Basement Walls: 1. Basement Wall 1: Solid Concrete or Masonry,8.0'ht17.0'bg/8.0'insul, R-13.0 cavity insulation Comments: 2. Basement Wall 2:Wood Frame,9.0'ht/0.0'bg/8.0'insul,R-19.0 cavity insulation Comments: Windows: 1. Window 1:Wood Frame,Double Pane with Low-E,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?.[ I Yes I No Comments: Doors: 1. Door 1: Solid,U-factor:0.070 Comments: Heating and Cooling Equipment: 1. Boiler 1:Other(Exept Gas-Fired Steam),87 AFUE or higher Make and Model Number Air Leakage: Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage must be seated. Recessed lights must be 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly with a 0.5"clearance from combustible materials.If non-IC rated,the ffix-ture must be installed with a 3"clearance from insulation. Vapor Retarder: Required on the warm-in-winter side of all non vented framed ceilings,walls,and floors. Materials Identification: Materials and equipment must be installed in accordance with the manufacturer's installation instructions. Y [ ] I Materials and equipment must be identified so that compliance can be determined, [ ] I Manufacturer manuals for all installed heating and cooling equipment and service water heating I equipment must be provided. [ J . I Insulation R-values, glazing U-factors, and heating equipment efficiency must be clearly marked on I the building plans or specifications. 1 Duct Insulation: [ ] ( Supply ducts in unconditioned attics or outside the building must be insulated to R-11. [ ] ( Return ducts in unconditioned attics or outside the building must be insulated to R-6. [ J I Supply ducts in unconditioned spaces must be insulated to R-11. [ J I Return ducts in unconditioned spaces(except basements)must be insulated to R-2. I Insulation is not required on return ducts in basements. 4 Duct Construction: [ J I All joints,seams,and connections must be securely fastened with welds,gaskets, mastics (adhesives), mastic-plus-embedded-fabric, or tapes. Duct tape is not permitted. I Exception: Continuously welded and locking-type longitudinal joints and seams on ducts I operating at less than 2 in.w.g. (500 Pa). [ ] Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions. [ J I Cooling ducts with exterior insulation must be covered with a vapor retarder. [ ] I Air filters are required in the return air system. J I The HVAC system must provide a means for balancing air and water systems. I I Temperature Controls: [ J I Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space temperature set point of the largest zone. I I Electric Systems: [ J ( Separate electric meters are required for each dwelling unit. I Fireplaces: j ] y Fireplaces must be installed with tight fitting non-combustible fireplace doors. [ ] I Fireplaces must be provided with a source of combustion air, as required by the Fireplace construction I provisions of the Building Code of New York State,.the Residential Code of New York State or I the New York City Building Code,as applicable. I I Service Water Heating: [ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. [ J I Insulate circulating hot water pipes to the levels in Table 1. I I Circulating Hat Water Systems: [ ] I Insulate circulating hot water pipes to the levels in Table 1. I Swimming Pools: [ ] I All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. I { Heating and Cooling Piping Insulation: [ ] ( HVAC piping conveying fluids above 105°F or chilled fluids below 55 °F must be insulated to the levels in Table 2. Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes _ Heated Water Non-Circulating Runouts Circulating Mains and Runouts Temperature(F) Up to 1" Up to 1.25" 1.5"to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100430 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for RVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes wing System Types Range(F) 2"Runouts 1"and Less 1.25"to 2" 2.5"to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water,Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD(Building Department Use Only) AquaSEAL product clato shoot A9+f1 WEAL Technical Data Color glace Thickness ASTM D 3767 mlla Imm) 40 11;0161 PliablGly 0.45`F 1,43•C) ASTM D 19-70M No effect Tensile Strength,Membrane ASTM D Al2 psi Ra) 6I0 (4203) Unsile U-Bih,Film ASTM D'682 Psi IkPd) 5000 (3d,500) Elongolion ASTM D 412 96 400 min Puncture Resistance,Membrane ASTM 6 154 Ibt IN), 7.5 I300) Pool adheslon,'concrete ASTM D 903 Ibs/In IN/m) 10 (17521 Lop Adhesion ASTM D 167,6 IbaAn Wml S 1876) Water Absorption ASTM D 470 % .02 Permeancu ASTM E 96 Perna Ing/Pa.S.rt ) 0.02(i_>5) Hydrostatic Head R,al#lonc■ ASTM Oi 741 psi (kPa) 93(641) Cycling over Crack @.131 O1•CI,100 Cycles ASTM C 834 No effect Sail Burial GSATO$4.071211 16 weeks No effect niuuda w.a� VMWIAM s ti rs�wsstsaW�c t r r •M A. _ re3r�+►.sar KOW-0 M PA"04M�T uni�IbY NOTES: 1. TC MlraORI recommends AquoDUCT as a drainage composite and pratawan course, In Ileu of ApuoUUCT,MiwDR)1,OOY 300HV is an approved protection course, 2. Place 9"scrip ofAquoSEAL at all consmicU0n jolrta. 3. All exposed edges of the AgwPUCT Saacompomte shed drain must be cawrad v4th Wmr- Standard Foundation AiiswOly .Detail Agtuwoo I AquaSIAL DtSClAIMfLRcTDs tmiwmtuon}r� h.�;n wipl nasrrtr ra�r IsusJirrbn,Ippl(>,>3ytp d p+va�.rt1 nry aq s nsuu or�ue mnapone and waeuaua�p�ee.ewa,Fpni rla+tr� M=Om dOw sw pr otaq h�or +US tar tlw+ra off to maenad sM wlfalfvtl�s ua s it 441,ats � � e0P°v'K "ei'a^t�d4`ofda�su, PASv44 �•D2/bt MMIRIEW ,noW"Pwrl.dta„PM*JC s 800/900`d Z00# 99:91 500Z/01/90 809009 mn88N33n0,,S1 i8fYJ:WOJJ .......... y-_"."`-"-.._-,,, �.• c ,+� � product data ql sheet .!, CT 40 , p�rrliu�Wnir4>r1h�d Wan drilds' j PRODUCT NAME proarq;seem-by dunnetlr{g waiter TECHNICAL DATA AquvVVCt 40 away and providing a s wridary water See table for physical prcparties. Prefabricated brianso Composite' retention layer, Aypllc+sble Stdmttards:AquaDUGT 40 is PRODUCT DESCRIPTION paw eilinleaca 00 need'for brine g approved for mas with wnwtproofini AgaaISUCT 40 H an Intortnadim flow MU%u to the corwruttlon-slm wxwm by mast major waterproofing drainage composite conalatlag of a thee- - Aq wDUCT 40 allows for backGlling manufdcturor4 dirtt9stsiortal.hyllt dnnsitr polyethylene witFt use seinni exqvated svN. PACKAGING INFORMATION (MPE)core,and a nonwoven filer • Th►u dates the dndngye elBci -7- Fadcagfag AquaDUCT 40 Is available In fabr�se. compered to sand car-gravel: rolls of Z by 50'(0.61in by I5.7Am)and The Altar fabric Is bonded w that INSTALLATION A'by SO'(122M by 1514 n). Individual dimples of the molded AgusrdUGT 40 an ba aaaily trimNad Ave tobAtr.AWaDUCT 40 is made In the polyethylene cote to.mintrNze fabrle wing the following procadurax VSA and Is sold through a highly Intruslon into the flow channels caused Attach�a uall#led stein repraaentadvit network, AguOPUCT!40 peals using q by beckflll pressure-The fabric serval as the apP'opriaTe pastel aarMchment Agv4DUCr 40 is readily avihme fi ore a i fl>tar medium w preveni the pas W systems-M1,MCK.M1,BOND tope "ud m of TC MIraDRI of soil particlim Into the core while or mechanical lwtmars=compatible warehouses. allowing subgrade moisture to pass 'yO the xubstnot.1hoAquoDUCf'40 Coat Consult your TC MI ORI freely. - will be parmanently secured when back. represantaltivna for price quotes. &vk Use'AquaDUCT 40 Is dasigneci'ler filling has been completed CAUTIONILIMITAT14yN5 use In vertical strigla-sided subsurface The fabric din AqupDUCT 40.panala " LbttiR ulsravtolat exposure by baclxGUing drWQW VIRIkattons,tie lreWmedtatta . extends beyond the Roof the within 7 days.of irtsUllation,Any panels flow rate and compressW strtir t polyetb`ylerte core°ta provide overlap for ' 60god during btsta l lan should be makes AWOUCt 40 ideal for use In the adjacent panels.When placing panels r eplacv!by the Installer. rostdendml and shallow depth applica- aid rmato each other,overlap fabric In MAMiTENANCE Bona where h1yh4low.high-rompreasive the direction of water ffew.Cover all ter- atvangth requirwttents do not exist elm)eta with the Alter fabric Nap by AquabUC C 40 wait dreams require no tucift k behind the core. maintaitvtce after.installation. The flat side of AQuaDUCT 40 flea .. diraegy aVdnst wall surfaces ma"it For.an Allgregati five dtdnagn rXern. WARRANTY ideal for foundstlon waft,rot gniing walls. Place Qu dcORAIN as required In dwlilp TC MirmPRl warrants that the product and other almllar structurst. ' details.The QukkDRAlN should be that,It sells will conform to the AquaDUCT 40 afsa sm V. as a protec- Installed sdlacent=o the AquaDUCT40. spotfllaldons P41111ited M this llcornua-a On tootle wmrAquoSEAL Wain- Care mein be taken to ehlum a For Itdorntation on limiradom to this coritinuous drainu�e path betwanett tin. `"'�t4•ccntace TG MiraM proofing Membranes, QukkDFWN and the AquaDUCT gO ponds, FEATURES AND SENEIRM Far installations where a collector pipe Ica - Non Rotting specified,encapsulate the collector pipe - Imptxvlous eta root penetraWM In a gravel bad whit a supplimmerntal sec. - Excellent thernid resistance. den of Niter fabric as a sepamtodilke _ - Waffectud by bacterW attack or frme `gockf ilpngr Baddilf 9hnuld be placed thaw gmlet Imunadtateil,eaddlll to at Wan six. - Conslstnt grin Proved IWW MM Inclt�t agave dta.eop edge of the ' perfamtrico due to a muht-directional .A4mPUCT CIO. core con9gur ittlon providing a uniform *these vdd*ets sun ar a halls p m aadadarl, flow pmsh for waver w escape; ddaased irsat VWME for h9ft*Vqn xnnd air - Enhancement of wWrprgafls�/eiamp- tim are hieWded b dia pm&a padoft 800/LOO'd ZOO# 99.9E, SWZ/01/90 8098MOS Mn8SN]3nq_sua:wojj T ♦ oa ♦ • • • sheet - .��tfvil�brfrinp wah�reoflsg 1�ifi�fl6lr+vilg� Pi4ODUCT t1AML or block must helve jolne struck of Avwla ?fity:AonNAL is made in AquoSFAL ".When walls arwrough,,use a well the USA and Is sold thrau;h,s 41bly PRODUCT DIS,9CRIPTION adhered Pkvw ooac vo crvm a smooth qualified salas hsprosarwtadve network uaSE.fAi.Is a Palkalharing sheet su hoe.When appiftAgWNAL to AgtwSEAL is rnadlllr shakable from>< wood surfaces,Iniurha that this substrate national system ofTC"mPlIAi membrane'"'WAS AS of 36"Is(91 rnm) is dry,darn.Ilrm.slid smooth. warehouaaa, I of rubbe*ed asphaltI mMaW tc 4 mica • (1mm).atpehhadtylsfnecsslafma Apply MinaDli(AYVrarf3804Frbnar Cam Consult yourTChllraDRl - minimum 40 mil(i.D rnm)membrane. Gn conenite.blocit and dl"o panels we reprasantndva for price quotes. The combination of two axceltant w,tta, htthiy.,ccommend the use of P 104 CA1!3'lIQNiLI["ItTAT1ONlS p^oailrtg nratarGsls pmmldsa!an inwnsadl- pArow.Prktte A*the am'which can ace battler for ilwllow dapFh fohrrdsdcn- be W Mrmsd widr man+bme In a worldna ��-should not be appltad on deu!a- ju*bsad r!asidast l applica6 fu da*Arsas 9rimad and not coves id with 4Wmn walls higher than IMAquaSSAL murnbranewithin 24 hours should b4 should be applied at tampetatury above f3atk t/se: reprimed.trouble cover on ItWde and , 257(•3,99Q.Do not story AqucVAL in AguMAL'mambrana.M wad for verdod outside Corners using a 9"(229rm�t)swp dlreCt sunlight or at temp!Grlinxriss ' wstetgrvollne on betvw-grade structural °f membrane. dint 951 QVC). krreper tdundwdon walls. could t aee ad to product ditaiorstion On vertical satiate more dien making proper installrtion of AqudSPAI S(Mrn)h10- wAgxSMmimbwe dff .cute. AWMAL should be ceevarad with hdther should.be applied in two-or more sec. 200Yt3W V Pmsasction Course or fins with*in upper section i MAINTINANCIE Aeitroi7t,tCTdralnW composites, oa+arh"ft Vus lower.&gln u(ttM ApdMAL requires no maintenum afbw. bosom, orthe vertical place ind work installation. _ FEATURES 6,NO dENEisi'F5. upward,conetnsnrlly pneft the mam- YIIARRa4NT9 •Fully adhered rnambrane.EI'anirusprs basset to alas surfaa.Sldti laps 9h!aiEid bet TC MOM warrens that the product' winter mkmdon which can otherwise rt minimum of 2•fl2"(b3,5n'an)surd end cause loaiage through crida. taps a minlnurrn of 5"(127mrn).AgvoSatrl that it sells Will conform to dw spne& . •Facto controlled thickness. membrane should be roped Y It h plsced cations published its this Ilwaturo,For Factory ass ban good hhfaf atdlrnsion. Information on Iasi tadons to this •Say to apply.Can be applied*Iddy warrant;contaceTG~PA.. and+sadly in th!s 541d. All cut wise wrmhitlon s must,be sealed wWa ouvft eel bend of MM0 Mudc,Ire ,TEGMN1CAwr.51:RYICE3 INS TAF1ATit3N Compacts technical assistanca is avast. Concrim surki es which will r ece" (3.173mcn)dick by 3W(19115mm)wide. able fiom TC Mkoopj and Its:alas membrane muff be thus.'dry hind free represeriiiadves.Services Include olvolds,pna(acdans loose mitariais, 3J4"jl90Sntrh)beret ofUM-i101l, assistance during dseign and spaalfica- dust,oil,urncograbie curing compounds . item stages as welt as Inklal stages In or other conwntnants,whirls could -membrane ehould not- instal�lan. lrnpatr peNbrsrtanea, belslkesposed eQ uttrw4olet rMs fore pwW wmading 10 drgs vdsheuter promo. 14ANUFACTURP-R Concrete must be dry before application 'a"a vourwa such a>I Minis Wv/39ow or "f'C MUM of membrane:Conc'rmst!a should be ACT drairalgo wmposlars. MlrnCiltl Mire)won Products curasi a mininiurn of 7 d ys.lightweight `Aeu Jatdef M nm a v basis for 60260MIL 2170 Satft ON&Idte 350 structural connate must be dried for a t aMW t aucuum P ko0gv*n And mrnmsfr on Dtk*CA 30097AW4 minimum of Sit days.Curing compounds Rmw., VM 60 2627•P"464-7234 should be a dear rresirr+bamrd rnetmial 'iECHNICAL DATA 669 26M wRheut waxes.olls,or pylmenes,Form 'See tablil for phyflcai properties. rahase agents that do not transfer to � the coreciete fie also MCOMmended. MCKMIM I14PtiRMAT1ON AvaSlFAI,may also be applied to f it membrane Is 3 L>° concrete blodc,brick masonry, (.914trr)wide by 75'92JMm)•long, - polyAtyrene tnsuladon veal{Farirslrlg �`j21m)per rail. !' f syaaat er Wood WdWay.Smooth brick Rats vwdghf'7i lbs.(35.9ira- J 800/VoOod Z00#. tr9*1 8OOZ/0I/90 809009 Mn85N33n0-S11dn3:W0a3 3i� PIE �. i l�• �J r �a FA,Er+ta� N. co ?� Cb '] - ' � � y•F A C3mo CD ' to L �=CID:r B3 b'c C yCD i y)o3 5 CD ) �1 120 /1 D(o7. c? 3"a 5OM OCO Li to 8 37 ' t8(.Sy me C> r UTILITIES W 72,21. MAP REFERENCE: MAP OF SECTION TWO 5TONEHURST A SUBDIVISION DEVELOPED BY CHARLES + BEVERLY MAINE DATED, JULY 2g. 1g87 LAST REVISEDs JANUARY 25. ig95 BY- VAN DUSEN + STEVES 0 N 0 6) — — � — 20' DRAINAGE — S86 ° 37' 30"E — - - EASEMENT — 1067.49 — 15' SETBACK v 350.53' N86037'30"W 15' SETBACK DS 'UNAUTHORIZED ALTERATION OR ADDITION TO A SURVEY BEARING A LICENSED LAND SURVEYORS SEAL IS A ^MAP &�(/� VIOLATION OF SEC RON n09. SUB -DIVISION z, OF THE /^y NEW YORK STATE EDUCATION LAW.' RIXfDLY COPESPROM THE OrThELN WXSURVEY MARKfD W7m All OIUfAlto-1 OF mL LAND WRVCYORS SEAL SHALL BE CONSIDERED TO BE VAUD TRUE COPIES.' 'CERTIFlCATIONS INDICATED HEREON SIGNIFY THAT L a n d S i V THIS SURVEY WAS PREPARED IN ACCORDANCE VAm THE BY THE CODE OF PRACTICE FOR LAND SURVEYORS ADOPTED THE NEW STATE ASSOCIATION OF PROFESSIONAL V y LA ORS. LAND SURVEYORS. SAID CERTIFICA110NS SHALL RUN ONLY TO THE PERSON FOR WHOM THE SURVEY IS PREPARED. AND 169 Haviland Road Queensbur New !York 12804 y, ON HIS BEHALF TO THE TITLE COMPANY, GOVERNMENTAL AGENCY AND LENDING LISTED HEREON, AND To me Ass�crve�s or me w�al�c Ir:STITUnoN LENDING (518) 792-8474 New York Lic., No. 50135 28. 77' N86031'20"W 65 278,152 sq.ft. 6.39 acres 1028.20 Map made for SCOTT A. & MARIE A. TYNON Town of Queensbury, Warren County, New York 795.88' 76°14'20"W 1 6129104 NO. DATE MCI HOUSE LOCATION DESCRIPTION I �o 1 0 N w Scale 1'=50' S-1 SET 1 OF 1 TYNON DWG- NO. 031GO