Technical Specs kasselmansoLAR PV Labeling Guide* 1. RATED MPP CURRENT AMPS RATED MPP VOLTAGE VOLTS MAX SYSTEM VOLTAGE voe MAX CIRCUIT CURRENT AMPS 8. . 3. WARN ING: PHOTOVOLTAIC POWER SOURCE 13. &WAR NING PHOTOVOLTAIC SYSTEM COMBINER PANEL DO NOT ADD LOADS 1. LABEL, PV DC DISCONNECT OPERATING SPEC, PLACE 1PER INV,ERTER 2. WA RNING LABEL,DC, PLACE 1 PER INV ERTER AND DC JUNCTION BOX. 3. WARNING LABEL,DC, PLACE 1 EVERY 10' OF CONDUIT, REFLECTIVE. 4. LABEL INDICATING PV HAS RAPID SHUTDOWN, PLACE 1ON METER, REFLECTIVE. 5. LABEL INDICATING MAIN BREAKER HAS BEEN DOWNSIZED, PLACE 1 NEAR MAIN. 6. WA RNING LABEL,INDICATING METERIS BACK FED BY PV, PLACE 1ON METER 7 (a)(b). LABEL INDICATING WHERE PV DISCONN ECT IS SITE. 8. LABEL INDICATING PV DISCONNECT,PLACE 1 ANYWHERE PV CAN BE DISCONNECTED,REFLECTIVE. 4. PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN 5. 10. 11. 9. LABEL INDICATING PV OVER CURR ENT DEVICE, PLACE 1NEAR ALL PV BREAKERS EXCEPT MAIN. 10. WARNING LABEL,AC , PLACE 1PER AC JUNCTION BOX,COMBINER PANEL,DISCONNECTS,ALL ELECTRICAL LOAD CENTERS. 11. LABEL, PV AC DISCONNECT OPERATING SPEC, PLACE 1AT ALL LOCATIONS PV AC CAN BE DISCONNECTED. 6. THIS SERVICE METER IS ALSO SERVED BY A PHOTOVOLTAIC SY STEM 12. RATEDAC OUTPUT CURRENT A NOMINAL OPERATING AC VOLTAGE v DUAL POWER SUPPLY 12. WARNING LABEL, PLACE 1 ON COMBINER PANEL, DISCONN ECT,OR TAP LOCATION. 13. WARNING LABEL, PLACE 1 ON COMBINER PANEL *NOTE - LABELS AR E SITE SPECIFIC. SOURCES: UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM Kasselman Solar,LLC 279 Broadway Bldg. 2 Menands, NY ·1 2204 (518) 320-7669 A WARNING ELECTRICAL SHOCK HAZAR D TERM NALS ONTHE LINE AND LOADSIDES MAY BE ENERGIZED JNTHE OPEN POSITION &WARNING £ WAR NING TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL PV SOLAR BREAKER DO NOT RELOCATE THIS OVERCURRENT DEVICE PHOTOVOLTAIC SYSTEM A DC DISCONNECT A DO NOT UP SIZE MAIN BREAKER BREAKER WAS DOWN-SIZE FOR PV SYSTEM CONNECTION PHOTOVO LTA IC SYSTEM A AC DISCONNECT A SOLAR DISCONNECT Q.PEAK DUO XL-G10.2 475-495 ENDURING HIGH PERFORMANCE BREAKING THE 21 % EFFICIENCY BARRIER Q.ANTUM DUO Z Technology with zero gap cell layout boosts module efficiency up to 21.6 %. LOW ELECTRICITY GENERATION COSTS Higher yield per surface area, lower BOS costs and up to 80 watts more module power than standard 144 half-cell modules. ENDURING HIGH PERFORMANCE Long-term yield security with Anti LID Technology, Anti PID Technology1, Hot-Spot Protect and Traceable Quality Tra.Q™. EXTREME WEATHER RATING High-tech aluminium alloy frame, certified for high snow (5400 Pa) and wind loads (2400 Pa). A RELIABLE INVESTMENT Inclusive 12-year product warranty and 25-year linear performance warranty2. STATE OF THE ART MODULE TECHNOLOGY Q.ANTUM DUO combines cutting edge cell separation and innovative 12-busbar design with Q.ANTUM Technology. 1 APT test conditions according to IEC/TS 62804-1:2015, method B (−1500 V, 168 h) 2 See data sheet on rear for further information. THE IDEAL SOLUTION FOR: Ground-mounted solar power plants PRELIMINARY Minimum Minimum MECHANICAL SPECIFICATION Format 2216 mm × 1045 mm × 35 mm (including frame) Weight 26.5 kg Front Cover 3.2 mm thermally pre-stressed glass with anti-reflection technology Back Cover Composite film 2216 mm 1308 mm 790 mm 400 mm 4 × Grounding holes, Ø 4.5 mm 4 × Drainage holes 4 × Mounting slots system Tracker (DE TAIL B) 454 mm Frame Anodised aluminium Cell 6 × 26 monocrystalline Q.ANTUM solar half cells Junction box 53-101 mm × 32-60 mm × 15-18 mm Protection class IP67, with bypass diodes Cable 4 mm² Solar cable; (+) ≥ 700 mm, (−) ≥ 350 mm* Connector Stäubli MC4-Evo2, Hanwha Q CELLS HQC4; IP68 1001 mm Label 4 × Mounting slots (DETAIL A) ≥ 700 mm ≥ 350 mm Frame 8 × Drainage holes 3 × 6 mm 1003 mm 1045 mm *Long cables (+) ≥ 1450 mm, (−) ≥ 1450 mm for landscape installation are available upon request. 35 mm 16 mm DETAIL A 21 mm 8.5 mm 10 mm DETAIL B 22 mm 7 mm ELECTRICAL CHARACTERISTICS MINI MUM PERFORMANCE AT STANDARD TEST CONDITIONS, STC1 (POWER TOLERANCE +5 W / −0 W) Power at MPP1 PMPP [W] 475 480 485 490 495 Short Circuit Current1 ISC [A] 11.24 11.26 11.29 11.31 11.34 Open Circuit Voltage1 VOC [V] 53.58 53.61 53.64 53.68 53.71 Current at MPP IMPP [A] 10.66 10.71 10.76 10.81 10.86 Voltage at MPP VMPP [V] 44.54 44.81 45.07 45.33 45.59 Efficiency1 η [%] ≥ 20.5 ≥ 20.7 ≥ 20.9 ≥ 21.2 ≥ 21.4 MI NIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS, NMOT2 Power at MPP PMPP [W] 356.4 360.1 363.9 367.6 371.4 Short Circuit Current ISC [A] 9.05 9.07 9.09 9.12 9.14 Open Circuit Voltage VOC [V] 50.53 50.56 50.59 50.62 50.65 Current at MPP IMPP [A] 8.39 8.43 8.47 8.52 8.56 Voltage at MPP V MPP [V] 42.49 42.72 42.94 43.17 43.39 1 Measurement tolerances PMPP ± 3 %; ISC; VOC ± 5 % at STC: 1000 W/m2, 25 ± 2 °C, AM 1.5 according to IEC 60904-3 • 2 800 W/m², NMOT, spectrum AM 1.5 100 98 95 90 Q CELLS Industry standard for linear warranties* At least 98 % of nominal power dur- ing first year. Thereafter max. 0.5 % degradation per year. At least 93.5 % of nominal power up to 10 years. At least 86 % of nominal power up to 25 years. 110 100 90 86 85 80 0 5 10 15 20 All data within measurement toler- ances. Full warranties in accordance with the warranty terms of the Q CELLS sales organisation of your 25 respective country. 80 200 400 600 800 1000 IRRADIANCE [W/m²] *Standard terms of guarantee for the 10 PV companies with the highest production capacity in 2014 (as at: September 2014) YEARS Typical module performance under low irradiance conditions in comparison to STC conditions (25 °C, 1000 W/m2). TEMPERATURE COEFFICIENTS Temperature Coefficient of ISC α [% / K] +0.04 Temperature Coefficient of VOC β [% / K] −0.27 Temperature Coefficient of PMPP γ [% / K] −0.34 Nominal Module Operating Temperature NMOT [°C] 43 ± 3 PROPERTIES FOR SYSTEM DESIGN Maximum System Voltage VSYS [V] 1500 PV module classification Class II Maximum Reverse Current IR [A] 20 Fire Rating based on ANSI / UL 61730 C / TYPE 1 Max. Design Load, Push / Pull Max. Test Load, Push / Pull [Pa] [Pa] 3600 / 1600 5400 / 2400 Permitted Module Temperature on Continuous Duty −40 °C - +8 5 °C QUALIFICATIONS AND CERTIFICATES IEC 61215:2016; IEC 61730:2016. This data sheet complies with DIN EN 50380. Certification in process. Note: Installation instructions must be followed. See the installation and operating manual or contact our technical service department for further information on approved installation and use of this product. Hanwha Q CELLS GmbH Sonnenallee 17-21, 06766 Bitterfeld-Wolfen, Germany | TEL +49 (0)3494 66 99-23444 | FAX +49 (0)3494 66 99-23000 | EMAIL sales@q-cells.com | WEB www.q-cells.com Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE POWER CLASS 475 480 485 490 495 RELATIVE EFFICIENCY COMPARED TO NOMINAL POWER [%] RELATIVE EFFICIENCY [%] Specifications subject to technical changes © Q CELLS Q.PEAK DUO XL-G10.2_475-495_2021-01_Rev01_EN PRELIMINARY PV power optimization at the module-level Specifi designed to work with SolarEdge inverters Up to 25% more energy Fast installation with a single bolt Next generation maintenance with module- level monitoring Superior effi (99.5%) Mitigates all types of module mismatch losses, from manufacturing tolerance to partial shading Flexible system design for maximum space utilization Meets NEC requirements for arc fault protection (AFCI) and Photovoltaic Rapid Shutdown System (PVRSS) Module-level voltage shutdown for installer and fi efi er safety solaredge.com Power Optimizer For North America P320 / P340 / P370 / P400 / P401 / P405 / P485 / P505 25 YEAR WARRANTY POWER OPTIMIZER Power Optimizer For North America P320 / P340 / P370 / P400 / P401 / P405 / P485 / P505 P340 P370 Optimizer model P320 (for high- (for higher- (typical module (for 60-cell power power compatibility) modules) 60-cell 60 and 72- modules) cell P400 P401 P405 (for 72 & (for high (for high- 96-cell power 60 voltage modules) and 72 cell modules) modules) P485 P505 (for high- (for higher voltage current modules) modules) INPUT Rated Input DC Power(1) 320 340 370 400 405 485 505 W Absolute Maximum Input Voltage (Voc at lowest temperature) 48 60 80 60 125(2) 83(2) Vdc MPPT Operating Range 8 - 48 8 - 60 8 - 80 8-60 12.5 - 105 12.5 - 83 Vdc Maximum Short Circuit Current (Isc) 11 10.1 11.75 11 14 Adc Maximum Efficiency 99.5 % Weighted Efficiency 98.8 98.6 % Overvoltage Category II OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Maximum Output Current 15 Adc Maximum Output Voltage 60 85 Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) Safety Output Voltage per Power Optimizer 1 ± 0.1 Vdc STANDARD COMPLIANCE EMC FCC Part15 Class B, IEC61000-6-2, IEC61000-6-3 Safety IEC62109-1 (class II safety), UL1741 Material UL94 V-0 , UV Resistant RoHS Yes INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc Compatible inverters All SolarEdge Single Phase and Three Phase inverters Dimensions (W x L x H) 129 x 153 x 27.5 / 5.1 x 6 x 1.1 129 x 153 x 33.5 / 5.1 x 6 x 1.3 129 x 153 x 29.5 /5.1 x 6 x 1.16 129 x 159 x 49.5 / 5.1 x 6.3 x 1.9 129 x 162 x 59 / 5.1 x 6.4 x 2.3 mm / in Weight (including cables) 630 / 1.4 750 / 1.7 655 / 1.5 845 / 1.9 1064 / 2.3 gr / lb Input Connector MC4(3) Single or dual MC4(3)(4) MC4(3) Input Wire Length 0.16 / 0.52 m / ft Output Wire Type / Connector Double Insulated / MC4 Output Wire Length 0.9 / 2.95 1.2 / 3.9 m / ft Operating Temperature Range(5) -40 - +85 / -40 - +185 ˚C / ˚F Protection Rating IP68 / NEMA6P Relative Humidity 0 - 100 % (1) Rated power of the module at STC will not exceed the optimizer “Rated Input DC Power”. Modules with up to +5% power tolerance are allowed (2) NEC 2017 requires max input voltage be not more than 80V (3) For other connector types please contact SolarEdge (4) For dual version for parallel connection of two modules use P485-4NMDMRM. In the case of an odd number of PV modules in one string, installing one P485 dual version power optimizer connected to one PV module. When connecting a single module seal the unused input connectors with the supplied pair of seals. (5) For ambient temperature above +85°C / +185°F power de-rating is applied. Refer to Power Optimizers Temperature De-Rating Technical Note for more details. PV System Design Using Single Phase Three Phase for Three Phase for a SolarEdge Inverter(6)(7) HD-Wave Single phase 208V grid 277/480V grid Minimum String Length (Power Optimizers) P320, P340, P370, P400, P401 8 10 18 P405, P485, P505 6 8 14 Maximum String Length (Power Optimizers) 25 25 50(8) Maximum Power per String 5700 (6000 with SE7600-US - SE11400- US) 5250 6000(9) 12750(10) W Parallel Strings of Different Lengths or Orientations Yes (6) For detailed string sizing information refer to: http://www.solaredge.com/sites/default/files/string_sizing_na.pdf (7) It is not allowed to mix P405/P485/P505 with P320/P340/P370/P400/P401 in one string (8) A string with more than 30 optimizers does not meet NEC rapid shutdown requirements; safety voltage will be above the 30V requirement (9) For 208V grid: it is allowed to install up to 7,200W per string when the maximum power difference between each string is 1,000W (10) For 277/480V grid: it is allowed to install up to 15,000W per string when the maximum power difference between each string is 2,000W © SolarEdge Technologies Ltd. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 07/2020/V02/ENG NAM. Subject to change without notice. Single Phase Inver ter with HD-Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US / SE7600H-US / SE10000H-US / SE11400H-US 12-25 YEAR WARRANTY Optimized installation with HD-Wave technology Specifi designed to work with power optimizers UL1741 SA certifi for CPUC Rule 21 grid compliance Record-breaking 99% weighted efficiency Small, lightweight, and easy to install both outdoors or indoors Quick and easy inverter commissioning directly from a smartphone using the SolarEdge SetApp Built-in module-level monitoring Fixed voltage inverter for longer strings Integrated arc fault protection and rapid shutdown for NEC 2014, NEC 2017 and NEC 2020 per article 690.11 and 690.12 Optional: Faster installations with built-in consumption metering (1% accuracy) and production revenue grade metering (0.5% accuracy, ANSI C12.20) solaredge.com INVERTERS Single Phase Inver ter with HD-Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US/ SE7600H-US / SE10000H-US / SE11400H-US MODEL NUMBER SE3000H-US SE3800H-US SE5000H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US APPLICABLE TO INVERTERS WITH PART NUMBER SEXXXXH-XXXXXBXX4 OUTPUT Rated AC Power Output 3000 3800 @ 240V 3300 @ 208V 5000 6000 @ 240V 5000 @ 208V 7600 10000 11400 @ 240V 10000 @ 208V VA Maximum AC Power Output 3000 3800 @ 240V 3300 @ 208V 5000 6000 @ 240V 5000 @ 208V 7600 10000 11400 @ 240V 10000 @ 208V VA AC Output Voltage Min.-Nom.-Max. (211 - 240 - 264)        Vac AC Output Voltage Min.-Nom.-Max. (183 - 208 - 229) -  -  - -  Vac AC Frequency (Nominal) 59.3 - 60 - 60.5(1) Hz Maximum Continuous Output Current @240V 12.5 16 21 25 32 42 47.5 A Maximum Continuous Output Current @208V - 16 - 24 - - 48.5 A Power Factor 1, Adjustable - 0.85 to 0.85 GFDI Threshold 1 A Utility Monitoring, Islanding Protection, Country Configurable Thresholds Yes INPUT Maximum DC Power @240V 4650 5900 7750 9300 11800 15500 17650 W Maximum DC Power @208V - 5100 - 7750 - - 15500 W Transformer-less, Ungrounded Yes Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 400 Vdc Maximum Input Current @240V(2) 8.5 10.5 13.5 16.5 20 27 30.5 Adc Maximum Input Current @208V(2) - 9 - 13.5 - - 27 Adc Max. Input Short Circuit Current 45 Adc Reverse-Polarity Protection Yes Ground-Fault Isolation Detection 600k Sensitivity Maximum Inverter Efficiency 99 99.2 % CEC Weighted Efficiency 99 99 @ 240V 98.5 @ 208V % Nighttime Power Consumption < 2.5 W (1) For other regional settings please contact SolarEdge support (2) A higher current source may be used; the inverter will limit its input current to the values stated Single Phase Inver ter with HD-Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US/ SE7600H-US / SE10000H-US / SE11400H-US MODEL NUMBER SE3000H-US SE3800H-US SE5000H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US ADDITIONAL FEATURES Supported Communication Interfaces RS485, Ethernet, ZigBee (optional), Cellular (optional) Revenue Grade Metering, ANSI C12.20 Optional(3) Consumption metering Inverter Commissioning With the SetApp mobile application using Built-in Wi-Fi Access Point for Local Connection Rapid Shutdown - NEC 2014, NEC 2017 and NEC 2020, 690.12 Automatic Rapid Shutdown upon AC Grid Disconnect STANDARD COMPLIANCE Safety UL1741, UL1741 SA, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07 Grid Connection Standards IEEE1547, Rule 21, Rule 14 (HI) Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size / AWG Range 1'' Maximum / 14-6 AWG 1'' Maximum /14-4 AWG DC Input Conduit Size / # of Strings / AWG Range 1'' Maximum / 1-2 strings / 14-6 AWG 1'' Maximum / 1-3 strings / 14-6 AWG Dimensions with Safety Switch (HxWxD) 17.7 x 14.6 x 6.8 / 450 x 370 x 174 21.3 x 14.6 x 7.3 / 540 x 370 x 185 in / mm Weight with Safety Switch 22 / 10 25.1 / 11.4 26.2 / 11.9 38.8 / 17.6 lb / kg Noise < 25 <50 dBA Cooling Natural Convection Operating Temperature Range -40 to +140 / -40 to +60(4) ˚F / ˚C Protection Rating NEMA 4X (Inverter with Safety Switch) (3) Inverter with Revenue Grade Meter P/N: SExxxxH-US000BNC4; Inverter with Revenue Grade Production and Consumption Meter P/N: SExxxxH-US000BNI4 . For consumption metering, current transformers should be ordered separately: SEACT0750-200NA-20 or SEACT0750-400NA-20. 20 units per box (4) Full power up to at least 50˚C / 122˚F; for power de-rating information refer to: https://www.solaredge.com/sites/default/files/se-temperature-derating-note-na.pdf How to Enable Consumption Monitoring By simply wiring current transformers through the inverter's existing AC conduits and connecting them to the service panel, homeowners will gain full insight into their household energy usage helping them to avoid high electricity bills © SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 12/2020/V01/ENG NAM. Subject to change without notice. Smart EV Charger For North America Smart EV Charging with SolarEdge Wi-Fi enabled, level 2 charging station, with up to 40A (9.6kW) charging power Control and monitoring via app - including remote operations, smart scheduling and charging history Industry-leading 5-year warranty(1) Rated for indoor or outdoor use Plug-in unit, easily modified to support hardwired installations(2) Suitable for use with or without a SolarEdge PV system Optimized charging, when connected to a SolarEdge inverter(3): Charges EV with up to 100% renewable energy by using excess-solar mode(4) Synchronizes with the full SolarEdge ecosystem (PV, home backup, and smart home devices), all managed by a single mobile app Faster charging with the unique Solar Boost mode, utilizing both grid and available PV simultaneously(3) (1) For additional information regarding the EV charging cable warranty terms please refer to: https://www.solaredge.com/warranty (2) Hardwired installation by professional installer only (3) Supports AC connection to Energy Hub and HD-Wave inverters only. A dedicated solar boost kit (SE-EV-KIT-V3UPG-01) is required for connection to standard HD-Wave inverters (4) SolarEdge import/export meter and communication connectivity with the SolarEdge inverter are required for controlled excess solar charging solaredge.com 5 YEAR WARRANTY SMART ENERGY Smart EV Charger For North America EV CHARGER SPECIFICATIONS Charging Mode AC Level 2 Rated AC Power Output 9.6 kW Maximum Continuous Output Current @240Vac 40(1) A Nominal AC Output Voltage @240Vac 240(2) Vac Nominal AC Frequency 60 Hz Ground Fault Detection Threshold 5 mA Supported Communication Interfaces Wi-Fi (built-in antenna included)(3), Ethernet, RS485 and Cellular (optional)(4) CABLE SPECIFICATIONS EV Connector SAE J1772-2009 Length 25 / 7.6 ft / m Weight 12.5 / 5.7 lb / kg FEATURES SUPPORTED WITH COMPATIBLE SOLAREDGE INVERTERS Smart Energy Management Smart schedules, excess solar charging(5), solar boost mode ADDITIONAL FEATURES Status LEDs, Fault Indicator Yes Unplugging Detection Yes, current termination according to SAE J1772 Ground Connection Monitoring Yes, continuous Monitoring and Control Installer commissioning via SetApp Homeowner configuration, controls and monitoring via mySolarEdge mobile app STANDARD COMPLIANCE EMC FCC Part 15 Class B Safety UL2594, UL2231-1, UL2231-2, NEC Article 625 compliant , CSA C22.2#280 Energy StarTM Certified - SE-EV-SA-US-40 INSTALLATION SPECIFICATIONS AC input NEMA 6-50 / NEMA 14-50 / Hardwired Dimensions (H x W x D) 12 x 7.3 x 6 / 309 x 190 x 154 in / mm Weight 6.3 / 2.85 lb / kg Protection Rating (connected to EV or with dust cap) NEMA 3R Operating Temperature Range -22 to +122 / -30 to +50 F / ˚C (1) Additional available settings: 16A, 24A, 32A and 40A (2) Connected to L1, L2, G; No need for neutral (3) To extend Wi-Fi communication, use optional Wi-Fi antenna. For antenna specification refer to: https://www.solaredge.com/sites/default/files/se-wifi-zigbee-wireless-antenna-datasheet-na.pdf (4) Optional cellular kit can be ordered (5) When Smart EV Charger is connected to the inverter, an import/export meter is required for controlled excess solar charging Product Number Description SE-EV-SA-KIT-LJ40N Smart EV Charger- including cable and holder. NEMA 14-50 AC plug SE-EV-SA-KIT-LJ40P Smart EV Charger- including cable and holder. NEMA 6-50 AC plug SE-EV-KIT-25J40-2 Replacement EV charging cable SE-EV-HLD-T1-V2 Replacement cable holder © SolarEdge Technologies Ltd. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 08/2021 DS-000097-1.0-NA. Subject to change without notice. ORDERING INFORMATION