Loading...
Site-Plan-Review APP_COMPILED1 Site Plan Review application – Revised October 2016 Town of Queensbury Planning Office-742 Bay Road, Queensbury, NY 12804 TOWN OF QUEENSBURY Site Plan Review Application Review Process: 1. Required Pre-submission meeting with staff to determine general completeness to be held no later than 1 week prior to deadline day. Call (518) 761-8265 or (518) 761-8220 for an appointment. 2. Submittal of complete application: 1 original and 14 copies of the application package by monthly deadline. 3. Determination of application completeness. All necessary information must be provided and appropriate fee(s) paid for consideration for placement on an agenda for that month. 4. Incomplete applications will not be considered for placement on any agenda until all missing information has been submitted. 5. Submittal to Warren County Planning, if applicable. 6. Planning Board meeting, generally the third & fourth Tuesday of each month. You will be advised in writing as to which meeting to attend. 7. Following the meeting you will be provided with a copy of the resolution stating the Board’s decision on your application. If your application was approved, the next likely step is a Building Permit. Final drawings must be provided for the next phase of review. If your application was denied, your project cannot proceed as submitted. DOCUMENTATION REQUIREMENTS (hard copy & electronic): Please submit 1 original & 14 copies of the completed application package to include: • Completed Application pages 2-9, signed & dated • Pre-Submission Meeting Notes: signed by staff • Copy of Deed • Checklist & Plot Plan • Environmental Assessment Form for any non-residential project • Fee: $100 (0 – 10,000 sq. ft.); $250 (10,001 – 30,000 sq. ft.); $500 (30,001 -100,000 sq. ft.); $1,000 (100,000+ sq. ft.) Staff & Contact Information: Craig Brown, Zoning Administrator craigb@queensbury.net Laura Moore, Land Use Planner lmoore@queensbury.net Sunny Sweet, Office Specialist – Planning sunnys@queensbury.net (518) 761-8220 Visit our website at www.queensbury.net for further information and forms 2 Site Plan Review application – Revised October 2016 Town of Queensbury Planning Office-742 Bay Road, Queensbury, NY 12804 General Information Tax Parcel ID Number: ____________________ Zoning District: ____________________ Lot size: _____________________ Detailed Description of Project [includes current & proposed use]: __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ Location of project: ________________________________________________________________________________ Applicant Name: Address: Home Phone Cell: Work Phone Fax E-Mail: Agent’s Name: Address: Home Phone Cell: Work Phone Fax E-mail Owner’s Name Address Home Phone Cell Work Phone Fax E-mail 3 Site Plan Review application – Revised October 2016 Town of Queensbury Planning Office-742 Bay Road, Queensbury, NY 12804 Site Development Data Area / Type Existing sq. ft. Proposed Addition sq. ft. Total sq. ft. A. Building footprint B. Detached Garage C. Accessory Structure(s) D. Paved, gravel or other hard surfaced area E. Porches / Decks F. Other G. Total Non-Permeable [Add A-F] H. Parcel Area [43,560 sq. ft. / acre] I. Percentage of Impermeable Area of Site [I=G/H] Setback Requirements Area Required Existing Proposed Front [1] Front [2] Shoreline Side Yard [1] Side Yard [2] Rear Yard [1] Rear Yard [2] Travel Corridor Height [max] Permeability No. of parking spaces 4 Site Plan Review application – Revised October 2016 Town of Queensbury Planning Office-742 Bay Road, Queensbury, NY 12804 Additional Project Information 1. Will the proposal require a Septic Variance from the Town Board of Health? _______________ 2. If the parcel has previous approvals, list application number(s): _________________________ 3. Does this project require coverage under the New York State Pollutant Discharge Elimination System (SPDES) Permit Program ? _______________ 4. Estimated project duration: Start Date __________ End Date __________ 5. Estimated total cost of project: _______________ 6. Total area of land disturbance for project: _______________ Floor Area Ratio Worksheet FLOOR AREA RATIO (FAR) -- The relationship of building size to lot size, derived by dividing the total building floor area by the lot size in square feet, yielding a percentage. Zoning District Symbol Floor Area Ratio [FAR] Waterfront Residential WR 0.22 Commercial Moderate/ Intensive CM/ CI 0.3 A. The combined area of all square footage, as measure from exterior walls of all structures on the property, including all floors of the structures, garages, basements and attics with more than five (5) feet of ceiling height and covered porches. Building square footage does not include: Open deck, docks and that portion of covered docks extending over water and one storage shed of one hundred twenty (120) square feet or less. Any additional sheds will be included. (See “FLOOR AREA RATIO”). B. Commercial or industrial: the total area in square feet as measured from the exterior of the outside walls of a building or structure, and when applicable, the sum total of all floor areas of the principal and accessory buildings or structures on the project site. A. Parcel Area ___________________________ sq. ft. B. Existing Floor Area ___________________________ sq. ft. [see above definition] C. Proposed Additional Floor Area ___________________________ sq. ft. D. Proposed Total Floor Area ___________________________ sq. ft. E. Total Allowable Floor Area ___________________________ (Area x _____) [see above table] *If D is larger than E. a variance or revisions to your plan may be needed. Consult with Staff. 5 Site Plan Review application – Revised October 2016 Town of Queensbury Planning Office-742 Bay Road, Queensbury, NY 12804 § 179-9-080 Requirements for Site Plan Approval. The Planning Board shall not approve a Site Plan unless it first determines that such site plan meets the following Standards. Please prepare responses to each of the following topics: STANDARDS A. The proposed project furthers or is consistent with the policies of the Town’s Comprehensive Plan. B. The proposed project complies with all other requirements of this Chapter, including the site plan review standards as set forth in Paragraph F of this section, the dimensional, bulk and density regulations of the zoning district in which it is proposed to be located (Article 3 and Table 1), the applicable requirements of all other Articles that apply. C. The site plan encourages pedestrian activity internally and, if practicable, to and from the site with pedestrian paths or sidewalks connected to adjacent areas. D. The site plan must conform to Chapter 136 Sewage and Sewage Disposal, Chapter 147 Stormwater Management Local Law, and other applicable local laws. E. The proposed use shall be in harmony with the general purpose or intent of this Chapter, specifically taking into account the location, character and size of the proposed use and the description and purpose of the district in which such use is proposed, the nature and intensity of the activities to be involved in or conducted in connection with the proposed use and the nature and rate of any increase in the burden on supporting public services and facilities which will follow the approval of the proposed use. F. The establishment, maintenance and operation of the proposed use will not create public hazards from traffic, traffic congestion or the parking of vehicles and/or equipment or be otherwise detrimental to the health, safety or general welfare of persons residing or working in the neighborhood or to the general welfare of the town. Traffic access and circulation, road intersections, road and driveway widths and traffic controls will be adequate. G. Off-street parking and l9oading facilities will be appropriately located and arranged and sufficient to meet traffic anticipated to be generated by the new use. The establishment of vehicle links between parking areas of adjacent properties are provided where feasible. This furthers the Town’s goal of reducing curb cuts and reducing congestion. A twenty-foot wide connection is required. If adjacent properties are either undeveloped or previously developed without having made provision for future linkage, then a future connection must be identified and provided for in the site plan under review for such future linkage when the time arises. The Planning Board may require proof that the applicant has made contact with adjacent property owners for purposes of coordinating linkages with adjacent properties. H. The project shall not have an undue adverse impact upon the natural, scenic, aesthetic, ecological, wildlife, historic, recreational or open space resources of the town or the Adirondack Park or upon the adequate provision of supporting facilities and services made necessary by the project, taking into account the commercial, industrial, residential, recreational or other benefits that might be derived from the project. In making the determination hereunder, the Planning Board shall consider those factors pertinent to the project contained in the development considerations set forth herein under § 179-9-080 of this Chapter, and in so doing, the Planning Board shall make a net overall evaluation of the project in relation to the development objectives and general guidelines set forth in § 179-9-080 of this Article. I. The provision for and arrangement of pedestrian traffic access and circulation, walkway structures, control of intersections with vehicular traffic and overall pedestrian convenience shall be safe and adequate for pedestrian movement. Pedestrian connections between adjacent sites shall be provided to encourage pedestrian use. J. Stormwater drainage facilities will prevent an increase of post development drainage flows as compared to pre-development drainage flows. Drainage of the site shall recharge ground water to the extent practical. Surface waters flowing off-site shall not degrade any streams or adversely affect drainage on adjacent properties or public roads. Facilities shall be in conformance with the drainage standards of Chapter 147 of the Town Code and the Town of Queensbury Subdivision Regulations where applicable. K. The water supply and sewage disposal facilities will be adequate and will meet all applicable and current requirements set forth by Department of Health regulations and Chapter 136 of the Town Code. L. The adequacy, type and arrangement of trees, shrubs and other suitable plantings, landscaping and screening shall effectively provide a visual and/or noise buffer between the applicants and adjoining lands, including the maximum retention of existing vegetation and maintenance, including replacement of dead or deceased plants. M. Fire lanes, emergency zones and fire hydrants will be adequate and meet the needs and requirements of emergency service providers. N. The design of structures, roadways and landscaping in areas susceptible to ponding, flooding and/or erosion will minimize or avoid such impacts to the maximum extent practicable. O. The site plan conforms to the design standards, landscaping standards and performance standards of this chapter. 6 Site Plan Review application – Revised October 2016 Town of Queensbury Planning Office-742 Bay Road, Queensbury, NY 12804 § 179-9-050 Checklist-Application for Site Plan Review. Application materials and site plan shall include sufficient information for the Board to review and provide a decision. The applicant is to provide a site plan drawing and all attachments that address items A-V. The applicant may request a waiver from A-V and is to provide reasons for waiver(s) requested. Please label information to be submitted. REQUIREMENTS Sheet # A. A vicinity map drawn at the scale that shows the relationship of the proposal to existing community facilities which affect or serve it, such as roads, shopping areas, schools, etc. The map shall also show all properties, identify owners, subdivisions, streets and easements within 500 feet of the property. Such a sketch may be superimposed on a United States Geological Survey map of the area. B. The site plan shall be drawn at a scale of forty feet to the inch (1” = 40 feet) or such other scale as the Planning Board may deem appropriate, on standard 24” x 36” sheets, with continuation on 8 l/2 “x 11” sheets as necessary for written information. The information listed below shall be shown on the site plan and continuation sheets. C. Name of the project, boundaries, date, north arrow, and scale of the plan. D. Name and address of the owner of record, developer, and seal of the engineer, architect or landscape architect. If the applicant is not the record owner, a letter of authorization shall be required from the owner. E. The location and use of all existing and proposed structures within the property, including all dimensions of height and floor area, all exterior entrances, and all anticipated future additions and alterations. F. The location of all present and proposed public and private ways, off-street parking areas, driveways, outdoor storage areas, sidewalks, ramps, curbs, paths, landscaping, walls and fences. Location, type and screening details for all waste disposal containers shall also be shown. G. The location, height, intensity and bulb type (sodium, incandescent, etc.) of all external lighting fixtures. The direction of illumination and methods to eliminate glare onto adjoining properties must also be shown in compliance with § 179-6-020. H. The location, height, size, materials and design of all proposed signs. I. The location of all present and proposed utility systems including: 1. Sewage or septic system; 2. Water supply system; 3. Telephone, cable and electrical systems; and 4. Storm drainage system including existing and proposed drain lines, culverts, catch basins, headwalls, endwalls, hydrants, manholes and drainage swales. J. Plans to prevent the pollution of surface or groundwater, erosion of soil both during and after construction, excessive runoff and flooding of other properties, as applicable. A Stormwater Pollution Prevention Plan (SWPPP) for all land development activities (excluding agricultural activities) on the site that results in land disturbance of one acre or more. A SWPPP shall comply with the requirements of the DEC SPDES MS-4 General Permit and Chapter 147 of the Town of Queensbury Code. It shall be at the discretion of the Planning Board as to whether a SWPPP or an erosion and control plan shall be required for a site plan review project land disturbance of less than one acre. K. Existing and proposed topography at two-foot contour intervals, or such other contour interval as the Planning Board shall allow. All elevations shall refer to the nearest United States Coastal and Geodetic Bench Mark. If any portion of the parcel is within the 100-year floodplain, the area will be shown and base flood elevations given. Areas shall be indicated within the proposed site and within 50 feet of the proposed site where soil removal or filling is required, showing the approximate volume in cubic yards. L. A landscape plan showing all existing natural land features than may influence the design of the proposed use such as rock outcrops, stands of trees, single trees eight or more inches in diameter, forest cover and water sources and all proposed changes to these features, including sizes and types of plants. Water sources include ponds, lakes, wetlands and watercourses, aquifers, floodplains and drainage retention areas. M. Land Use District boundaries within 500 feet of the site’s perimeter shall be drawn and identified on the site plan, as well as any Overlay Districts that apply to the property. 7 Site Plan Review application – Revised October 2016 Town of Queensbury Planning Office-742 Bay Road, Queensbury, NY 12804 REQUIREMENTS (CONTINUED) Sheet # N. Traffic flow patterns within the site, entrances and exits, loading and unloading areas, as well as curb cuts on the site and within 100 feet of the site. The Planning Board may, at its discretion, require a detailed traffic study for large developments or for those in heavy traffic areas, which shall include: 1. The projected number of motor vehicle trips to enter or leave the site, estimated for weekly and annual peak hour traffic levels; 2. The projected traffic flow pattern including vehicular movements at all major intersections likely to be affected by the proposed use of the site; 3. The impact of this traffic on levels of service on abutting public streets and at affected intersections. Existing and proposed weekly and annual peak hour traffic levels and road capacity levels shall also be given. O. For new construction or alterations to any structure, a table containing the following information shall be included: 1. Estimated area of structure to be used for particular purposes such as retain operation, office, Storage, etc.; 2. Estimated maximum number of employees; 3. Maximum seating capacity, where applicable; and 4. Number of parking spaces existing and required for the intended use. P. 1. Floor Plans. 2. Elevations at a scale of one-quarter inch equals one foot (1/4” = 1 foot) for all exterior facades of the proposed structure(s) and/or alterations to or expansions of existing facades, showing design features and indicating the type and color of materials to be used. Q. Soil logs, water supply well and percolation test results, and storm water runoff calculations as needed to determine and mitigate project impacts. R. Plans for disposal of construction and demolition waste, either on-site or at an approved disposal facility. S. Plans for snow removal, including location(s) of on-site snow storage. T. An Environmental Assessment Form (“EAF”) as required by the SEQRA regulations, with Part 1 completed by the Applicant shall be submitted as part of the application. If the proposed project requires a special use permit and an EAF has been submitted in conjunction with a special use permit application, a duplicate EAF is not required for the site plan application. U. If an application is for a parcel or parcels on which more than one use is proposed, the applicant may submit a single application for all such uses, provided the proposed uses are accurately delineated on a site plan drawn pursuant to the requirements set forth above. The Planning Board may grant the application with respect to some proposed uses and not others. For purposes of reviewing an application (and for SEQRA compliance) all proposed uses on a single parcel or on contiguous parcels shall be considered together. V. A brief narrative statement on how the project proposed for review furthers or is consistent with the vision, goals and policies in the Town’s Comprehensive Plan. Town of Queensbury Site Plan Pre-Submission Conference Form / Section 179-9-040 1. Applicant Name: __________________________________________________ 2. Tax Map ID ________________ Location: _______________________ 3. Zoning Classification __________ 4. Reason for Review: __________________________________________________________ 5. Zoning Section #: ________________________ 6. Pre-Submission Meeting Notes:Provided Outstanding; Please provide by Deed __X__ _____________ General Information complete ____ _____________ Site Development Data Complete ____ _____________ Setback Requirements Complete ____ _____________ Additional Project Information Complete ____ _____________ FAR addressed ____ _____________ Requirements for Site Plan-Standards ____ _____________ Checklist items addressed ____ _____________ Environmental Form completed ____ _____________ Signature Page completed ____ _____________ Staff Representative: ________________________________ Applicant / Agent: ________________________________ Date: ___________ Foothill Builders 309.10-1-24&25 78-80 Main Street MS -0.76 ac Tear down construct new building with first floor office/retail with a second and third floor of 24 apartment -footprint of 8,663 sq ft 179-3-040MS,179-7-030, 179-7-020, 179-7-070, 140 X X X X NA X X X review green space for site review green space for parking Main Street checklist and SPApplication Checklist Unlisted-agenda, staff notes,reso Laura Moore via email 03/21/2022 Applicant proposes removal of existing structures and to construct a new building with a footprint of 8,663 sq ft for first floor office/retail with a second and third floor of 24 apartment. Site work to include parking/drive area, lighting, landscaping and stormwater. Site plan for new uses and multi story building in the Main Street zone. Items reviewed - site plan application, elevations, floor plans, site plans, stormwater Items to be updated or provided 1) 2)Checklist page 6 and 7 and Main Street Checklist a) floor plan for first floor, how many tenants, b)side setback 79% proposed minimum is 60% however a waiver is trigger for the need to access the rear property for parking, c) setback to rear of building on plan sheet should be noted, d)elevation views are limited - noting primary shop entrances will be located on main street with recessed doors -there are only two doors shown and no defined tenant spaces it is not clear if this would access two shops- there probably should be more than two, e) generic facade provided-attractive open store fronts are to be provided 179-7-020 D Design Standards specific to Main Street, f) tenants for first floor, g) calculation to be provided for the front facade-50% of front facade at least 18 inches deep and 3 ft wide but no more than 10ft deep, h) interconnect to the adjoining lot to be shown on plans and details for interconnect should be provided, i) supporting parking information will be needed where if the max required 49 spaces and 25 spaces would be the 50% for shared and 38 spaces would be provided - parking only seems to be provided for apartments, j) landscaping very few trees are provided will need explanation may be need larger tree species --also sidewalk plantings, k) if greater than 20 stalls then at least 10% of interior - applicant to explain 1,504 sq ft, large shrubs - not sure if provided, l) buffer needs to be review between uses, additional information on fence between properties, m) elevation view need for parking/services, n) will need lighting information, o) side walk information, p) outdoor dining not identified , q) elevation plan indicates 12 ft but second floor 11 ft and third floor is 9 ft -where code indicated 12 ft for each floor, r) building transparency and interior lighting - calculation needs to be provided, s) floor to ceiling windows need to be evaluated to confirm they are code compliant, noting tinted glass is prohibited, t) sign information will need to be provided, u) building material needs to be provided, screening information needs to be provided, v) rooftop mechanicals information will be needed. -Additional discussion may be needed prior to submission of materials. 8 9 Site Plan Review application – Revised October 2016 Town of Queensbury Planning Office-742 Bay Road, Queensbury, NY 12804 Signature Page This page includes the 1.)Authorization to Act as Agent Form: 2.)Engineering Fee Disclosure; 3.)Authorization for Site Visits; 4.) Other Permit Responsibilities; 5.) Official Meeting Disclosure and 6.)Agreement to provide documentation required. OWNER’S AGENT FORM: Complete the following if the OWNER of the property is not the same as the applicant Owner: ____________________________________ Designates: ____________________________________ As agent regarding: _____ Variance _____ Site Plan _____ Subdivision For Tax Map No.: _____ Section _____ Block _____ Lot Deed Reference: _____ Book _____ Page _____ Date OWNER SIGNATURE: ___________________________________DATE: _______________ APPLICANT’S AGENT FORM: Complete the following if the APPLICANT is unable to attend the meeting or wishes to be represented by another party: Owner: ____________________________________ Designates: ____________________________________ As agent regarding: _____ Variance _____ Site Plan _____ Subdivision For Tax Map No.: _____ Section _____ Block _____ Lot Deed Reference: _____ Book _____ Page _____ Date OWNER SIGNATURE: ___________________________________DATE: _______________ 2.) ENGINEERING FEE DISCLOSURE: Applications may be referred to the Town consulting engineer for review of septic design, storm drainage, etc. as determined by the Zoning or Planning Department. Fees for engineering review services will be charged directly to the applicant. Fees for engineering review will not exceed $ 1,000 without notification to the applicant. 3.) AUTHORIZATION FOR SITE VISITS:By signing this page and submitting the application materials attached herein, the Owner, Applicant, and his/her/their agent(s) hereby authorize the Zoning Board or Planning Board and Town Staff to enter the subject properties for the purpose of reviewing the application submitted. 4.) OTHER PERMIT RESPONSIBILITIES:Other permits may be required for construction or alteration activity subsequent to approval by the Zoning Board or Planning Board. It is the applicant’s responsibility to obtain any additional permits. 5.) OFFICIAL MEETING MINUTES DISCLOSURE: It is the practice of the Community Development Department to have a designated stenographer tape record the proceedings of meetings resulting from application, and minutes transcribed from those tapes constitutes the official record of all proceedings. 6.) AGREEMENT TO PROVIDE DOCUMENTATION REQUIRED: I, the undersigned, have thoroughly read and understand the instructions for submission and agree to the submission requirements, I acknowledge no construction activities shall be commenced prior to issuance of a valid permit. I certify that the application, plans and supporting materials are a true and complete statement/description of the existing conditions and the work proposed, and that all work will be performed in accordance with the approved plans and in conformance with local zoning regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents, will obtain a certificate of occupancy as necessary. I also understand that I/we may be required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy I have read and agree to the above. ____________________________ ___________________________ __________________ Signature [Applicant]Print Name [Applicant] Date signed ____________________________ ___________________________ __________________ Signature [Agent]Print Name [Agent]Date signed                      Matthew Huntington 1/12/2021 Studio A Landscape Architecture and Engineering, DPC (Contact: Matthew Huntington) X 309.10 1 25 and 309.10-1-24 38 High Rock Ave, Suite 3 | P.O. Box 272 | Saratoga Springs, NY 12866 | 518.450.4030          FHB MAIN STREET APARTMENTS   78‐80 Main Street  Queensbury, NY     SITE PLAN REVIEW APPLICATION – Responses to Standards    A. The proposed project furthers or is consistent with the policies of the Town’s Comprehensive Plan.    The proposed project is located within the Main Street Zoning District and is consistent  with the policies of the Town’s Comprehensive Plan.     B.  The proposed project complies with all other requirements of this Chapter, including the site plan  review standards as set forth in Paragraph F of this section, the dimensional, bulk and density  regulations of the zoning district in which it is proposed to be located (Article 3 and Table 1), the  applicable requirements of all other Articles that apply.    The proposed project and related site usage comply with the Site Plan Review standards  set forth in this Chapter. The proposed project is not seeking any Zoning Board Approvals  and generally meets all the criteria set forth in the dimensional bulk and area table for  Main Street Zoning District.     C.  The site plan encourages pedestrian activity internally and, if practicable, to and from the site with  pedestrian paths or sidewalks connected to adjacent areas.     The proposed site layout encourages pedestrian use and internal flow through  integration of an internal courtyard, and walkways throughout the entirety of the parking  lot area. A. Connection to adjacent areas is not proposed at this time as adjoining parcels  are currently residential properties.    D.  The site plan must conform to Chapter 136 Sewage and Sewage Disposal, Chapter 147 Stormwater  Management Local Law, and other applicable local laws.    The site plan conforms to the Town’s ordinances noted above. Wastewater disposal and  potable water service is proposed by connection to existing municipal services. The  project proposes to accommodate stormwater management through the use of  subsurface infiltrator chambers located beneath the parking lot area.     E. The proposed use shall be in harmony with the general purpose or intent of this Chapter, specifically  taking into account the location, character and size of the proposed use and the description and  purpose of the district in which such use is proposed, the nature and intensity of the activities to  be involved in or conducted in connection with the proposed use and the nature and rate of any  increase in the burden on supporting public services and facilities which will follow the approval of  the proposed use.    The proposed use is in harmony with the purpose and intent of this Chapter and is in  conformance with design criteria set forth for the Main Street Zoning District. The  proposed development is not a significant amount in which it will produce a burden on  the public services.     F.  The establishment, maintenance and operation of the proposed use will not create public hazards  from traffic, traffic congestion or the parking of vehicles and/or equipment or be otherwise  detrimental to the health, safety or general welfare of persons residing or working in the  neighborhood or to the general welfare of the town. Traffic access and circulation, road  intersections, road and driveway widths and traffic controls will be adequate.    The proposed project will not create an unsafe condition for traffic, traffic congestion or  the parking of vehicles. A new driveway entrance will be constructed to accommodate  two‐way traffic. The entrance has been designed in general conformance with NYSDOT  minor commercial design criteria. The parking lot has been designed to accommodate  vehicle traffic generated by the proposed mixed office and apartment‐use. All required  distances for vehicle circulation and drive widths are adequate to accommodate  anticipated vehicle use.     G. Off‐street parking and loading facilities will be appropriately located and arranged and sufficient to  meet traffic anticipated to be generated by the new use. The establishment of vehicle links  between parking areas of adjacent properties are provided where feasible. This furthers the  Town’s goal of reducing curb cuts and reducing congestion. A twenty‐foot wide connection is  required. If adjacent properties are either undeveloped or previously developed without having  made provision for future linkage, then a future connection must be identified and provided for in  the site plan under review for such future linkage when the time arises. The Planning Board may  require proof that the applicant has made contact with adjacent property owners for purposes of  coordinating linkages with adjacent properties.     Adequate off‐street parking and loading facilities are provided within the site to  accommodate anticipated vehicle traffic generated from the proposed mixed  office/apartment‐use. All proposed parking areas are located at the rear of the building.  The proposed quantity of parking spaces does not meet the quantity required as  determined in accordance with Section 179‐4‐090 of the Town Code. In accordance with  Section 179‐7‐070(b)(4)(a)[2] of the Town Code, the Planning Board may reduce parking  requirements for development having more than one use. As such, the applicant is  seeking a reduction in required parking. A new driveway entrance is proposed under this  project scope to accommodate two‐way traffic.  The adjacent properties are currently  residential‐use and future linkage is therefore not a consideration at this time.       H. The project shall not have an undue adverse impact upon the natural, scenic, aesthetic, ecological,  wildlife, historic, recreational or open space resources of the town or the Adirondack Park or upon  the adequate provision of supporting facilities and services made necessary by the project, taking  into account the commercial, industrial, residential, recreational or other benefits that might be  derived from the project. In making the determination hereunder, the Planning Board shall  consider those factors pertinent to the project contained in the development considerations set  forth herein under § 179‐9‐080 of this Chapter, and in so doing, the Planning Board shall make a  net overall evaluation of the project in relation to the development objectives and general  guidelines set forth in § 179‐9‐080 of this Article.      The proposed project does not have an undue adverse environmental impact on the  natural, scenic, aesthetic, ecological, wildlife, historic, recreational or open space  resources of the Town. The existing site is developed and is serviced by the Town’s  municipal sewer and water utilities. The proposed development will utilize these  facilities. The proposed mixed‐use development is in conformance with the Main Street  Zoning District intent.     I. The provision for and arrangement of pedestrian traffic access and circulation, walkway structures,  control of intersections with vehicular traffic and overall pedestrian convenience shall be safe and  adequate for pedestrian movement. Pedestrian connections between adjacent sites shall be  provided to encourage pedestrian use.    The proposed site plan allows for safe pedestrian access and circulation within the site  through the use of sidewalks and walkways. Vehicular traffic is controlled by signage and  road markings.     J. Stormwater drainage facilities will prevent an increase of post development drainage flows  as compared to pre‐development drainage flows. Drainage of the site shall recharge  ground water to the extent practical. Surface waters flowing off‐site shall not degrade  any streams or adversely affect drainage on adjacent properties or public roads. Facilities  shall be in conformance with the drainage standards of Chapter 147 of the Town Code  and the Town of Queensbury Subdivision Regulations where applicable.    Currently there are no stormwater management practices on site. Proposed stormwater  management practices include a series of precast catch basins, roof leaders and  subsurface infiltrator chamber units located beneath the parking lot area.  The proposed  stormwater management system has been designed to attenuate peak discharge rates  for the 50‐year storm event to that less than pre‐existing.      K. The water supply and sewage disposal facilities will be adequate and will meet all applicable and  current requirements set forth by Department of Health regulations and Chapter 136 of the Town  Code.    The proposed sewage disposal and water supply will be connected to existing municipal  services. All requirements of the Town of Queensbury will be met.  All connections will be  made in coordination with the applicable Town Departments.     L. The adequacy, type and arrangement of trees, shrubs and other suitable plantings,  landscaping and screening shall effectively provide a visual and/or noise buffer between  the applicants and adjoining lands, including the maximum retention of existing  vegetation and maintenance, including replacement of dead or deceased plants.    Proposed buffering methods from adjacent uses are in conformity with requirements of  the Town Code. All property bounds with the exception of the northern property line will  be buffered with privacy fence to establish screening between adjacent residential  properties.      M. Fire lanes, emergency zones and fire hydrants will be adequate and meet the needs and  requirements of emergency service providers.    Fire lanes and emergency access is provided via Main Street. The proposed building will  we equipped with a fire suppression system.      N. The design of structures, roadways and landscaping in areas susceptible to ponding, flooding and/or  erosion will minimize or avoid such impacts to the maximum extent practicable.     The proposed development is within a relatively level area and is not susceptible to  ponding, flooding, and/or erosion. Positive drainage and several catch basins have been  integrated within the parking lot area to mitigate the potential for ponding.     O. The site plan conforms to the design standards, landscaping standards and performance  standards of this chapter.     The proposed site plan generally complies with the requirements listed in this chapter.  The applicant is seeking a reduction in parking requirements at the discretion of the  Planning Board, in accordance with Section 179‐7‐070(b)(4)(a)[2] of the Town Code.      Page 1 of 3 Short Environmental Assessment Form Part 1 - Project Information Instructions for Completing Part 1 – Project Information. The applicant or project sponsor is responsible for the completion of Part 1. Responses become part of the application for approval or funding, are subject to public review, and may be subject to further verification. Complete Part 1 based on information currently available. If additional research or investigation would be needed to fully respond to any item, please answer as thoroughly as possible based on current information. Complete all items in Part 1. You may also provide any additional information which you believe will be needed by or useful to the lead agency; attach additional pages as necessary to supplement any item. Part 1 – Project and Sponsor Information Name of Action or Project: Project Location (describe, and attach a location map): Brief Description of Proposed Action: Name of Applicant or Sponsor: Telephone: E-Mail: Address: City/PO: State: Zip Code: 1.Does the proposed action only involve the legislative adoption of a plan, local law, ordinance, administrative rule, or regulation? If Yes, attach a narrative description of the intent of the proposed action and the environmental resources that may be affected in the municipality and proceed to Part 2. If no, continue to question 2. NO YES 2.Does the proposed action require a permit, approval or funding from any other government Agency? If Yes, list agency(s) name and permit or approval:NO YES 3.a. Total acreage of the site of the proposed action? __________ acres b. Total acreage to be physically disturbed? __________ acres c. Total acreage (project site and any contiguous properties) owned or controlled by the applicant or project sponsor? __________ acres 4.Check all land uses that occur on, are adjoining or near the proposed action: 5. Urban Rural (non-agriculture) Industrial Commercial Residential (suburban) Aquatic Other(Specify):□ Forest Agriculture □ Parkland Page 2 of 3 5.Is the proposed action, a.A permitted use under the zoning regulations? b.Consistent with the adopted comprehensive plan? NO YES N/A 6.Is the proposed action consistent with the predominant character of the existing built or natural landscape?NO YES 7.Is the site of the proposed action located in, or does it adjoin, a state listed Critical Environmental Area? If Yes, identify: ________________________________________________________________________________ NO YES 8.a. Will the proposed action result in a substantial increase in traffic above present levels? b.Are public transportation services available at or near the site of the proposed action? c.Are any pedestrian accommodations or bicycle routes available on or near the site of the proposed action? NO YES 9.Does the proposed action meet or exceed the state energy code requirements? If the proposed action will exceed requirements, describe design features and technologies: _____________________________________________________________________________________________ _____________________________________________________________________________________________ NO YES 10.Will the proposed action connect to an existing public/private water supply? If No, describe method for providing potable water: _________________________________________ _____________________________________________________________________________________________ NO YES 11.Will the proposed action connect to existing wastewater utilities? If No, describe method for providing wastewater treatment: ______________________________________ _____________________________________________________________________________________________ NO YES 12. a. Does the project site contain, or is it substantially contiguous to, a building, archaeological site, or district which is listed on the National or State Register of Historic Places, or that has been determined by the Commissioner of the NYS Office of Parks, Recreation and Historic Preservation to be eligible for listing on the State Register of Historic Places? archaeological sites on the NY State Historic Preservation Office (SHPO) archaeological site inventory? NO YES 13. a. Does any portion of the site of the proposed action, or lands adjoining the proposed action, contain wetlands or other waterbodies regulated by a federal, state or local agency? b.Would the proposed action physically alter, or encroach into, any existing wetland or waterbody? If Yes, identify the wetland or waterbody and extent of alterations in square feet or acres: _____________________ _____________________________________________________________________________________________ _____________________________________________________________________________________________ NO YES b. Is the project site, or any portion of it, located in or adjacent to an area designated as sensitive for Page 3 of 3 14.Identify the typical habitat types that occur on, or are likely to be found on the project site. Check all that apply: □Shoreline □ Forest Agricultural/grasslands Early mid-successional Wetland □ Urban Suburban 15.Does the site of the proposed action contain any species of animal, or associated habitats, listed by the State or Federal government as threatened or endangered?NO YES 16.Is the project site located in the 100-year flood plan?NO YES 17.Will the proposed action create storm water discharge, either from point or non-point sources? If Yes, a.Will storm water discharges flow to adjacent properties? b.Will storm water discharges be directed to established conveyance systems (runoff and storm drains)? If Yes, briefly describe: _____________________________________________________________________________________________ _____________________________________________________________________________________________ NO YES 18.Does the proposed action include construction or other activities that would result in the impoundment of water or other liquids (e.g., retention pond, waste lagoon, dam)? If Yes, explain the purpose and size of the impoundment:______________________________________________ ____________________________________________________________________________________________ _ NO YES 19.Has the site of the proposed action or an adjoining property been the location of an active or closed solid waste management facility? If Yes, describe: _______________________________________________________________________________ _____________________________________________________________________________________________ NO YES 20.Has the site of the proposed action or an adjoining property been the subject of remediation (ongoing or completed) for hazardous waste? If Yes, describe: _______________________________________________________________________________ _____________________________________________________________________________________________ NO YES I CERTIFY THAT THE INFORMATION PROVIDED ABOVE IS TRUE AND ACCURATE TO THE BEST OF MY KNOWLEDGE Date: _____________________ Applicant/sponsor/name: ____________________________________________________ __________________________ Signature: _____________________________________________________Title:__________________________________ EAF Mapper Summary Report Monday, January 10, 2022 3:54 PM Disclaimer: The EAF Mapper is a screening tool intended to assist project sponsors and reviewing agencies in preparing an environmental assessment form (EAF). Not all questions asked in the EAF are answered by the EAF Mapper. Additional information on any EAF question can be obtained by consulting the EAF Workbooks. Although the EAF Mapper provides the most up-to-date digital data available to DEC, you may also need to contact local or other data sources in order to obtain data not provided by the Mapper. Digital data is not a substitute for agency determinations. Part 1 / Question 7 [Critical Environmental Area] No Part 1 / Question 12a [National or State Register of Historic Places or State Eligible Sites] No Part 1 / Question 12b [Archeological Sites]Yes Part 1 / Question 13a [Wetlands or Other Regulated Waterbodies] No Part 1 / Question 15 [Threatened or Endangered Animal] No Part 1 / Question 16 [100 Year Flood Plain]Digital mapping data are not available or are incomplete. Refer to EAF Workbook. Part 1 / Question 20 [Remediation Site]Yes 1Short Environmental Assessment Form - EAF Mapper Summary Report