Loading...
2003-852 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 1280475902 (518)761-8201 Community Development-Building&Codes (518)761.8256 C "I F ATEOF' OCCUPANry E I IC Permit Number: P20030852 Date Issued: Tuesday,April 13,2004 This is to certify that work requested to be done as shown by Permit Number P20030852 has been completed. Tax Map Number: 523400-308-008-0001-053-000-0000 Location: I I BURNT HILLS Dr Owner: BURNT HILLS LLC Applicant: CLUTE ENTERPRISES INC. This structure may be occupied as a: By Order of Town Board Garage-2 Cars Attached TOWN OF QUEENSBURY Single Family Dwelling Director of Building&Code Enforcement TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20030852 Application Number: A20030852 Tax Map No: 523400-308-008-0001-053-000-0000 Permission is hereby granted to: CTJJTFFNTFRPRTSES INC. For property located at: I I BURNT HILLS Dr in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans,and other information hereto filed and.approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: BURNT HILLS LLC 15 F BIRDIE Dr Garage ' 2 Cars Attached - Single Family Dwelling $130,000.00 QUEENSBURY,NY 12804-0000 Total Value $130,000.00 Contractor or Builder's Name Address Electrical Inspection Agency CLUTE ENTERPRISES INC. 13 DAWN Rd 01JEENSBURY. NY 12804 Plans&Specifications 2003-852 LOT#28 HSE#1'I BURNT HILLS DRIVE 1-580 SQ FT SINGLE FAMILY DWELLING WITH 2-CAR ATTACHED GARAGE AS PER PLOT PLAN SPECIFICATIONS $219.60 PERMIT FEE PAID-THIS PERMIT EXPIRES: Saturday, October 23,2004 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Quebnsbury before the expiration date.) Dated at thvfo—w'n-of Que b T ursday, October 23, 2003 for the Town of Queensbury. SIGNED BY lg$ Director of Building&Code Enforcement Building Permit Application Town of Queensbury-Dept of Community Development,742 Bay Road,Queensbury,NY (518)761-8256 A permit must be obtained before beginning construction. Permit File No. d No inspection will be made until applicant has received a Fee Paid $ valid building permit. All applicants' spaces on this Rec.Fee Paid $ application must be completed and must appear on the Reviewed By -I application form. Applicant: Owner: Address: Address: f"�4 1 c � Phone#(5-c Phone# Property Location: Lot Number: �- / douse Number / i' a< - --� 1`� )� Subdivision Name: Tax Map Number: .f!' ew Buil �rXsaijftgo-4e mmercial Estimated Market Value of Construction:$❑ Addition: mmercial If an Addition,what will use of new addition be? ❑ Alteration: residence I commercial ❑ No change to exterior size: residence/com'1 ❑ Other work(describe ) Check OeeupancyInformation 1` Floor Z" Floor Other floor Total Below sq.ft. sq.ft. sq,ft. Square Feet Single family dwelling . ❑ Two family dwelling ❑ Townhouse ❑ Multifamily dwelling #of units ❑ Office RA ❑ Mercantile 0 V E m ❑ Manufactunn ti ❑ 1 car detached garage ❑ 2 car detached garage ❑ 3 car detached garage F'F M 1'S8Agf-- 0 1 car attached garage 2 car attached garage �, c_lc� ❑ 3 car attached garage ❑ Storage building- commercial ❑ Storage building- residential ❑ Other What is the proposed height of the structure -�`? feet inches Will any second-hand or.ungraded lumber be used? if so,for what? . Type of Heating System- electric/ oil ;-Zs ;�- od /forced hot air/ baseboard/other: Number of FOwplaces to be installed Number of Woodstoves to be installed List below the person(s)responsible for supervision of work as regards to building codes: Name Address Phone Number Builder Plumber -__- ,. __ Mason Electrician Declaration: please sign below after you have carefully read the statement: To the best of my knowledge the statements contained in this application,together with the.plans and specifications submitted,are a true and complete statement of all proposed work to be done on the described premises and that all provisions of the Boil the Zoning Ordinance and ll other laws pertaining to the proposed work shall be complied with,whether a hied or n ted,and that such work is ed by the owner. Further,it is understood that I/we shall submit,p ' r'10 a Certificate f cup ate o Compliance being issued,,as requested by the Zoning A ator or Director o an ,an s B' It S iv by a licensed surveyor;drawn to scale,showing actual loc�an n a c Si a-- owner,owner's agent,arcbitect,contractor _ Application for Permit-Septic Disposal System Town of Queensbury 742 Bay Road Queensbury,NY 12804 (518) 761-8256 1. OWNER INFORMATION: kZ4- -C--OLar ............................................­1....................................................... .......... Office Use Location'of installation: Tax Map NO. Cyc 7 d SLT> File Permit No. Fee Paid Owner's Name: ................................... ...................................... .................................... Address: 2. INSTALLER'S NAME PHONE NO.'?:�> -7-!;-,-7'7 3. RESIDENCE INFORMATION: (circle year of dwelling,indicate#bedroom(s) and multiply#of bedrooms with applicable gallons per bedroom to equal total daily flow) Year of House: No.of Bedrooms x Computation Total Daily Flow 1980 or older x 150 gal/bdrm 1980- 1991 x 130 gal/bdrm 1991 -present x 110 gal/bdrm Garbage Grinder Installed yes Spa or Hot Tub Installed yes 4.' PARCEL INFORMATION: (circle applicable information&indicate measurements) ToRogrg p h� -Soil Nature Ground Water Bedrock or Impervious Material Dkomestip-Water SuDDIV a Rolling-- at what depth at what depth municipal h7am­ feet -feet we Steep slope clay if well; water supply %slope other from any septic-system depth: absorption is_ft. other Percolation Test: (To be completed by licensed professional engineer or architect ) Rate: minute per inch 5. PROPOSED SYSTEM: For New Construction: All individual sewage disposal systems must be designed by a licensed professional engineer or architect(unless installed in a Planning Board approved subdivision). Add 250 'gallons to the size of the septic tank and leach field for each Garbage Grinder, Spa or Whirlpool Tub, Septic Tank: gallon(min. size 1,000 gal.) Tile Field: each trench t. Total System Length: e240D ft. fi SeepagePit(s): number of size ofeach: ft. by_ft. Size of Stone to be used: # depth or thickness 1 11 feet Bed System Size: x Alternative System: length andlor size 6. HOLDING TANK SYSTEM: (if required) Number of tanks: Size of each:_gallons TOTAL Capacity: gallons Note: Alarm System and associated electrical work must be inspected by a Town approved electrical inspection-agency.. 7. SIGNATURE &INFORMATION FOR RESPONSIBLE PERSON(please read) For your protection,please note that pursuant to Section 136-29 of the Code of the Town of Queensbury,any permit or approval granted which is based upon or is granted in reliance upon any material misrepresentation or failure to make a material fact or circumstance known by or on behalf of an applicant, shall be void. I have read th egulations wi resppeft- this application and agree to abide by these and all requirem of the Town of u sb Sewage Disposal Ordinance.. t,i9nnttrre-of&rgp-onsible person Date �i ENERGY CODE COMPLIANCE APPLICATION + TOWN OF QUEENSBURY, WARREN COUNTY 9000 HEATING DEGREE DAYS Compliance Methods:Part 5 -Acceptable Practice Method— 1&2 Family Dwellings(only) Part 6*-Thermal Rating—Component trade Offs 1&2 Family Dwellli Multi�Family Dwellings(3 Stories or less) ZQjj3 iPart 4*-Design by Component Performance,Commercial Bu ll(I Rise Residential ; �� t� ju,,'168 *Requires submission of worksheets '�" C j APPLICANT'S NAME: PROPERTY LOCATION: PART 5 METHOD OF COMPLIANCE BY ACCEPTABLE PRACTICE: 1. Gross Floor Area �, square feet 2. Type of heat- Electric Oil Gas Other 3. Is building mechanically cooled? yes No: 4. Percentage of area of windows and doors Over 17% Under 17% ` 5. R VALUES FOR INSULATION GIVEN BELOW MUST CORRESPONDt TO R VALUES AS SHOWN ON PLANS SUBMITTED: a: Roof R ' b. Exterior walls R t c C. Glazed areas R '2-`T d. Exterior doors R tv- --5 C. Floors over unheated spaces R 9 f. Edge of slab on grade(heated building) R �--� g. Basement/cellar walls(above grade) R �— h. Basement/cellar walls(glow grade) R i. Heating/cooling-ducts-piping in unheated space R�� 6. Service(domestic)hot water heating device Conforms to minimum efficiency per code Y No TE )J TU NT 0. AXIMUM SETTING 140—WILL NOT BE EXEEDED Applic ature Date Phone Number - IN TO a MARKS: r� 0 z w w� W �u 0 can a zzo- H 04 w 0 � �W�z Ham✓ z ao� u41 H H z w wu � N w14u Ow © a H W ° ItD 0 co z rxH z i HH w a ,� H a z H z 0 W 4 u . a w z c� w 0 H W a H c� a u H a Q HH w H x H H a cn w W z W a D wa a w H M a cn a x a v, N N H u I H 0 w a cn ►a 0 w 4 a 0 W x x a z 0 wz xu zw xH Q 04 Hsn , HHU 4440 0 H. 9 1 W w 9 W a a 4 0 0 Q 9 4 u 9 9 u H a H u m > H H z H u > GA a H W, u o I x x z w Hz uaw . u '� w xa � G = W H H > H W W cn a 0 Q A H > W W W H z Q > w 0 a z co cn W H N w w w w w u N > 0 a 0 0 Z H a W W H a a a W z a N w z cnH Nu aN > H a 0 Z 0 0 4 a a a 9 4 ] N H 0 w 0H �+ z 0 0 0 H 0 0 w 0 0 0 H �t w a w H 0 zw W H z H z W N H x a Q z A 0 N 0 u u u a > H Ha z M H a H W a Q a H H H H a 0 H W W H H 0 z W u W W 4 W H H Q Q Q W w H H u H a 0w H 0 0 H 4 4 0 0 H 0 H 9 H H 9 z z z z H ' a 0 9 0H x 0 W w 0 z H H H W H X a Q ►� H H x 9 A H a U 4� a w a. W W H N w W Ul W . Wi W1 NI xj x 4 w V)j 1 0 MAP REFERENCE: BURNT HILLS SUBDIVISION DKC HOLDINGS, INC. DATED: JULY 23, 2001 LAST REVISED: JANUARY 17, 2002 BY: VAN DUSEN & STEVES, LLC 1 I HEREBY CERTIFY THAT THIS MAP WAS PREPARED FROM AN ACTUAL FIELD SURVEY. THIS CERTIFICATION SHALL RUN ONLY TO THE PERSONS FOR WHOM THE SURVEY WAS PREPARED. AND ON THEIR BEHALF TO THE TITLE COMPANY. GOVERNMENTAL AGENCI AND LENDING INSTITUTION LISTED HEREON. CERTIFICATIONS ARE NOT TRANSFERABLECRG INSTITUTIONS OR 5UBSEQUENT OWNERS. CERTIFIED TO@ RU55ELL J. DARLENE WELLS FARGO HOME MOINC.. IT'S SUCCESSORS AND/ GHIGAGO TITLE, "sue CERTIFIED BY,___---_ MATTHEW DATEDs MARCH 25. 2004 k CB CB W uu0- 0 4 U)Ir,,-q UTILITIE5 40.43' I — O � I STONE DRIVE I I I lfl 58—�'21 1�I nr.. 56.88' 28 27,669 sq. ft. 0.64 acres N Ln TN D/// 1GO.G5' N8G 13'50'W BUF LANDS OF NI AGARA MOHAWK POWER CORPORATION 3 LO O U) 0 '.0 D us e /, _ •� i/ Steves Land Survey ors 169 Haviland Road Queensbury, New York 12804 (518) 792-8474 New York Lic. No. 50135 "UNAUTHORIZED ALTERATION OR ADDITION TO A SURVEY NAP BEARING A LICENSED LAND SURVEYORS SEAL IS A VIOLATION OF SECTION 7209. SUB-DiViS10N 2. OF THEJVCCP. NEW YORK STATE EDUCATION LAW." 'ONLY COFILS FROM THE ORIGINAL OF TM15 SURVEY MARKED W&" AN ORIGINAL OF THE LAND 9URYEYOR9 SEAL SHALL BE CONSIDERED TO BE VMJO TRUE COPIES." "CERTIFICATIONS INDICATED HEREON SIGNIFY THAT THIS SURVEY WAS PREPARED IN ACCORDANCE WITH THE FOR LINO SURVEYORS ADOPTED BY THE NEW YORK STATE ASSOCIATION OF PROFESSIONAL CODE S. SAID TICECERTIFICATIONS IIND SURVEYORS. SAID CERTIFICATIONS SHALL RUN ONLY LAND SURVEYORS. TO THE PERSON FOR WHOM THE SURVEY IS PREPARED, AND ON HIS BEHALF TO THE TITLE COMPANY, GOVERNMENTAL AGENCY AND LENDING INSTITUITION LISTED HEREON, AND TO THE ASSIGN"5 Or THE LENDING INSTRUfION.• Map of a Survey made for D 1 S S ell & Darlene L. Palmer Russ i V Town of Queensbury, Warren County, New York Scale III -/COI S SHEET1 OF 1 PALMER DWG. NO. 99241-28 NO. DATE DESCRIPTION Y_r " Residential Final Inspection �Offige No. (518) 761-8256 Date Inspection request received: J 1 Queensbury Building&Code Enforcement Arrive: am/p epart: r J. am/pm `+ 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials:. NAME: PERMIT#:. LOCATION: / rr. ! DATE: 3 GAS "TYPE OF STRUCTURE: , �. // : ' ` Comments N N/A Chimney Ht.,/"B"Vent/Direct Vent Location Fresh Air IntakeCt� :i. 3"inch Plumb Vent through roof , Roof.Complete Guard 30 im.or more 2 stairs;decks,patios' Guard'at stairwell at 34 in.or more Guard'.at deck,porches 36 in.or more Exterior.Finish Complete Interior/Exterior Railings 34 in.to 38 in: j Platform at all exterior doors �Interior Handrails stairs.2 or more risers Grade away from foundation 6-in.with 10 ft. Handrail Termination at Newell Post or Wall 8 inch clearance to sill plate Gas Valve shut-off ex osed/regulator 18"above grade Gas Furnace shut-off within 30.ft,or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating , -Low water shut-offboiler Relief Valve(s)installed Interior privacy/trim./doors/main entrance 36 in. Bathroom/Kitchen watertight Safety lzin Window in stairwells safety,glazing Interior Smoke Detectors: Every level: % Every Bedroom: Outside every bedrooin area: Inter Connected: ! Batteiy backup: Bathroom Fans,if no window Carbon Monoxide detector Plumbing fixtures Foundation insulation Floor truss,draft stop2ing finished basement 1,000 sf Emergency Rmergency egress below grade ?C (��E 1/jd t.)<s f�. Basement stairs closed rise>4`inches i %hour fire door/door closer ' Garage fireproofing Duct work Sealed pr2p6dy Attic access 30 in.x 24 in.x 30 in.(ht.)In accessible area Crawl Spaces-18"x 2 'acce s, 1 s ,ft.-150 s . ft.vents ,Building No./Ad visi e m r d Final Electrical . nq Site Plan-/Vnri c -re u ed Final Survey Plot Plan ark 1 As Built Septic System/Sewer Dept,Ins ection.Sticker : Flood Plain Certification,if re aired Okay to issue C-/C(Cert.Of Compliance) Okay to issue Tempor C/O-(Cert: Of Occii anc Okay to issue Permanent C 1 O(Cert. Of Occupancy) L:\SueHemingwaylBuilding.Codes.Inspection.FORMS\ es.Final Insp.form 2.doe'edited January 28, 03 Queensbury Building & Code Enforcement-- Residential Final Inspection ffice No.(518)761-825.6- Arrive: 1 Com} a D t "f Date Inspection requ st received;. Inspector's Initia NAME: l' 0,IT M 3-&Sa LOCATION: ATE: 44 - TYPE OF STRUCTURE: Comments Y N . NIA f Chimney Ht./"B"Vent/Direct Vent Location ,� t ���D S2 �✓' Fresh Air Intake 1 3 inch Plumb Vent through roof minimum 6" Roof Complete/Exterior Finish Co m lete F Guard 30 in.or more(q),stairs,decks,patios Guard at stairwell at 34 in. or more Guard at deck,porches,36 in.or more Exterior Finish Complete Interior/Exterior Railings 34 in.to 38 in. `�C _ Platform at all exterior doors Interior Handrails stairs 2 or more risers V � Enclosed Stairs Sheetrock Underside minimum 'fs" Gypsum Grade away from foundation 6 in:with 10 ft. Handrail Termination at Newell Post or Wall 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18"above grade ��� Gas Furnace shut-off within 30 ft.or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler AAN:� Relief Valves installed/Heat Trap/Water Temp 110 Interior privacy/trim/doors/main entrance 36 in. Bathroom/Kitchen watertight Safety glazing/Window in stairwells safet glazing Interior Smoke Detectors: Every level: _ ,/ / 'Every Becj#oom: ✓ � — l _ Outside every bedroo rea: Inter Connected: 7 / Batter backu Carbon Monoxide Detector Bathroom Fans,if no window <✓ b-�"�. Plumbin fixtures - - - - _ n.� b Foundation insulation Floor truss,draft stopping finished basement 1,000 sf Emer ncy egress below grade Basement stairs closed rise>4 inches V. Garage Floor Pitched a Garage fireproofing/3/4 hour fire door/door closer Duct work Sealed, ro erl Gas Logs in Sealed or Glass Enclosure Attic access 30 in.x 22 in.x.30 in.(lit.)In accessible area . Crawl Spaces 18"x 24"access, 1-s .11.-150 s . ft.vents Building No./Address visible from road Final Electrical Site Plan /Variance required Final Survey Plot Plan As Built Septic System/ I e t' r Flood Plain Certificao6n,if fired Okay to issue C/C fr C./O em orar /Permanent] L:IPamWlBuilding&Codesiinspection Forms\Res.Final Insp. form.2.docLast printed 2/12/04 Rough Plumbing/ Insulation Inspection Report--v--__,._ Office No. (518)761-8256 Date Inspection e eive AP Queensbury Building&Code Enforcement Arrive. De r am/pm 742 Bay Road,Queensbuly,NY 12804 Inspecto 's is NAME: PERMIT#: LOCATION: INSPECT ON: A J_\T TYPE OF STRUCTURE: XD N N/A PVC: R-1,R-2,R-3,R-4 Drain Vents Cast Iron,Copper Drain/Vent Comm. Plumbing Vent/Vents in Place Rough P!upbing/Nail Plates Hea r Air Supply Test fain and Vents 5 PSI or 10 ft. above highest Connection for 15 minutes Water Supply Piping Copper Commercial Copper, CPVC,Pex One&Two Family Insulation/Residential Check/Commercial Check Proper Vent,Attic Vent Duct/Hot Water Piping Insulation If required unheated Taces Combustion Air Supply for Furnace Duct Work Sealed Properly COMMENTS: ,L:\SucIieming�vay\Building.Codes.Inspection.FORMS\Rough Plumbing Insulation Report.doc January 28,2003 -z- � Q6'R�\N'cD�� 0 Rough Plumbing/ Insulation Inspection Report 14,� Office No. (518)761-8256 Date Inspection requ eceived: Queensbury Building&Code Enforcement Arrive: a pm an-Jpm 742 Bay Road,Queensbury,NY 12804 Inspector's Initia . i 'P NAME: PERMIT#,. t/ ` LOCATION: &jjAj INSPECT ON: r TYPE OF STRUCTURE- Y N N/A PVC: R-1,R-2,R-3,R-4 Drain Vents Cast Iron,Copper Drain/Vent Comm. Plumbing Vent/.Vents in Place Rough Plumbing/Nail Plates Head or Air Supply Test Diain and Vents 5 PSI or 10 ft. above highest Connection for 15 minutes Water Sup ly Piping '�'Up Cop Commercial C per,CPVC,Pex One&Two Family N lation/Residential Check/Commercial Check Proper Vent,Attic Vent Duct/Hot Water Piping Insulation If required unheated Eaces Combustion Air Supply for Furnace Duct Work Sealed Properly COMMENTS: -L:\Suellemingway\Building.Codes.Inspection.FORMS\Rotigh Plumbing Insulation Report.doc January 28,2003 Framing / Firestopping Inspection Report Office No. (518)761-8256 Date Inspection request receivedc>4 Queensbury Building&Code Enforcement Arrive: am/ in z......Zt-am/pm 742 Bay Road,Queensbuly,NY 1.2804 Inspector's lnitials: �f`7- NAME: PERMIT D-� LOCATION: INSPECT ON: TYPE OF STRUJAC Y N N/A COMMENTS Framing Jack Studs Headers Bracing Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12'?O.C. Headroom 6 ft. 8 in. Stairwells 3 6 in.or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate I V2(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Ane r Bolts 6 ft. or less on center Xe and snow shield 24 inches from wall Fire separation 1, 2,3 hour Fire wall,2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min, Garage Fire Separation House side Vz inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in (H) 20 in. (W) 5.7 sf above I below grade 5.0 sf grade L:\SueHemingNvay\Building,Codes,lnspection.FORMS\FramingFirestopping Inspection Report.doc January 28,2003 Rough Plumbing/ Insulation Inspection Report Office No. 518 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/p Depart: am/pm 742 Bay Road,Queensbury,NY 12804 Inspector's Initials: NAME: PERMIT#: V LOCATION: ,LLS INSPECT ON: "c 0q TYPE OF STRUCTURE: Y N N/A PVC: R-1,R-2,R-3,R-4 Drain/Vents Cast Iron,Copper Drain/Vent/Comm. Pi bing Vent/Vents_in Place h P�luinb g%NairPlates eacl or,Air'-S pp y Test -Drain and Vents 5 PSI or 10 ft. above highest Connection for 15 minutes Water Supply Piping ��-- b Copper Commercial Copper,CPVC,Pex One&Two Family Insulation/Residential Check/Commercial Check Proper Vent,Attic Vent Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct Work Sealed Properly COMMENTS: •L:1SueIlemingway\Building.Codes.Inspection,PORMS\Rough Plumbing Insulation Report.doc January 28,2003 Framing Firestopping Inspection Report Office No. (518)761-8256 Date Inspection request received. Queensbury Building&Code Enforcement Arrive: am/ m Depart: ,,, m/pm 742 Bay Road, Queensbury,NY 1.2804 Inspector's Initials NAME: PERMIT#: LOCATION: - I�,` ,/ INSPECT ON: — TYPE OF STRUCTURE: Y N /A COMMENTS --- .aming Jack Studs-/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 3 6 in.or more Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal S ping for Notches Top Plate I 1 ) 16 gauge(8) 16D nails each side ft stopping 1,000 sq. ft, floor trusses Anchor Bolts 6 ft. or less on center Ice and snow shield 24 inches from wall Fire separation 1,2,3 hour Fire w , 3,4 hour Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side Yz inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\Sueliemingway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003 Foundation Inspection Report Office No. (518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/p Depart: am/pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: NAME: ( -:7 YI, PERMIT#: LOCATION: INSPECT ON: TYPE OF STRUCTURE: Comments N N/A Fo i gs Piers 1?46nolit&' Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump. Footing Drain Stone: 12 inch width 6 inches above footing 6 mil of for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\SucHemingway\Building.Codes.Inspectioii.FORMS\FoundationlnspqctionReport.doe January 28,2003 r._ Septic Inspection Report Office No. (518)761-8256 Date Inspection request received: f /�3 }�+� Queensbury Building& Code Enforcement Arrive: am/p epart: _ am/pm 742 Bay Rd.,Queensbug,NY 1,2804 Inspector's Initials: ar r NAME: PERMIT NO.: �ZoO 34o r�- LOCATION) 1 - r,,, INSPECT ON: l3 RECHECK.: Comments and/or diagram Soil t 5A4, y Type of WaterEMuni'cipZ Well Water Waterline separltiffdistance ft. Well separation distance ft. Other wells: ft. Absorption Field: Total length ft. Length of each trench ft. Depth of trenches ft. Size of Stone '7--✓ Seepage Pits: Number Size: x Stone Size: Piping Si Type, Building to tank Tank to Distribute ox u �� Distribution Box VT* ld/Pit Opening Sealed:LY/ /Partial Location/Separations Foundation to tank ft. Foundation to absorption ft. Separation of Pits ft. Conforms as per Plot Plan —V—Y N / �,. "r 0 Ci O Location Of System 0 0 y: Front Re eft Si Right Side Middle Fr nt 1 e Rear S stem Use Stat s: Approved Partial Approved and needs to be re-inspected,please call the Building&Codes Office Disapproved L:xSueHemingway\Building.Codes.Inspeation.FORMSISeptic Inspection Report.doc January 28,2003 - - r r : r ....,..,_... .�� k37 I , I I •• r 1 : r , I « r I , t , t. . , , I I i , .E t « • i I • I , , I r ' I f10i 9A)// Foundation Inspection Report Office No. (518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/p De rt: �amlpm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: NAME: PERMIT#: LOCATION: INSPECT ON: TYPE OF STRUCTURE: Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 i hes above footing mil-oolv for wet areas under slab ackfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:ISueRemingway\Building.Codes.Inspection.FORMS\Fbundation Inspection Report.doc January 28,2003 Foundation Inspection Report Office No. (518)761-8256 Date Inspection refit} st re e' ed: Queensbury Building&Code.Enforcement Arrive: ,� plm epart: a 'p 742 Bay Rd., Queensbuiy,NY 12804 Inspector's Initi ! r NAME: Q-DPERMIT#: l✓ LOCATION: �- SPECT ON: -- TYPE OF STRUCT . Comments Y N N/A Footings Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place" Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump_ Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior --- R- Rough Grade 6 inch drop within 10 ft. L:1SueHemingway\Building.Codes.Inspection.FORMs\Foundation Inspection Report.doe January 28,2003 r � r w Job Site Address: Date: o ' Ovcmer: . .t;z:? C _ Application No. File No. WINDOW SCHEDULE , Window Window Mfg, Window Unit or houghot}gh STpT( r SQ F Clear Clear Special Hardware or Number or Name Model Stock OpeAlrtg' Oentngc Glasss�b trent Egress/Cleat 0 e�m 0 enm filet ht Instructions Letter on Or Type Number r, i 2qw� °I eig ` lei" ' O entng dth In l"'Echesg Plan Cali Size rx f w aA 1 fip F t MRvm iR n a .: 37 Zip 37 .�`� -THIS .LINE HAS EXAMPLES OF SAMPLE ENTRIES nio::c. r'^, P"w°lir9#fir �c �' � f arro p"x;1 IS)' �1.7.1 R.i.t�.�wr y '" .e� "N., .r, w'';h ''9±:c' t4 xn:� Y ;If *e r. �Cr „•.a „y�,d'j, 5'1.4.5,�. Nn„ 'a^'1^ Giazm w iSU .. .j✓ �i ,5•. �"�C,'"<, ,,�'S".y t., .;�t.��� rM.rf��tt� t,��(� '� '� ,"',�tf• 'i f7h, .�"°�e� t ,,, �. '�..+:;1 r�� �' J t`r r k. .�,1 `�:� ,r5`+� t�S-. �r+.• nk.,:�Y.� ii»r"'1i�" a»5u,"ins rra'�ti`.�,i��'„�k���^ °�'+"v, ,i•;;R74`�.T�'Y.";��,�^�� �.�S��a , .,P;. L.1 ueHemingwaylBuilding.Pemit,FORMSiWindow Sehedule.doc "IN .rJ Job Site Address; o (��� �' .,� Date; 6 Owner: IZ t I LI , r =- -C A libation No, �� He No. Building Permit— Calculation Sheet Natural Light,'Ventilation & Emergency Egress Requirements Habitable Area of 112; Re .•Lit Actualw q gh Req.Vent Actual Sq.Ft, Remarks Room Room 8%of Room, Light 4°Ip of Room Vent Opening for m Area Square 41 Area Square r Egress q E q re Square , ` Footage ; Footage Feet hwA x^r� c � - 56" a a Sri ye• p,s w1'� M x WRI �^rtKa z ;1tN 0 �prl s + Dili von PSAJ�r �i �y4 cxy L:1SueHemingwaouilding.Permit.FQRMSWat.Light.Ventil.Calcuiation.Sheet.doc Y Check Residential Plan Review: One&Two Family Dwellings Y/N/N/A 2)Full sets of plans Over 1,500 sq. ft.—Stamped Design Loads On Plans:90 Wind Floor Loads 40 psf 70 Ground Snow Load Sleeping Areas and Attics 30 psf Calculations: in ow Schedule With Glass Size Door Schedule/Main Entrance 36"Door mergency Escape Or Bedrooms and Habitable Space Above/Below grade,5.7 sq.ft. Grade,5.0 sq.ft. 4"(h)x 20"(w)min. 44"Max.Hei t above floor Residential Check Paperwork Compliance and Inspectors Checklist: OK Dampproofing/Waterproofing Materials On Plans 40 Foundation Drainage On Plans,if required b"Drop in 10'Exterior Grade 'Framing Cross.Section For Each Roof Line,Vertical Fire Stopping Every 10'Where uired Ice and Snow shield 24"Inside Exterior Wall/24"Inside Knee Walls Platforms At Exterior Doors fairway Headroom 6' 8'All Stairs 36"Width air Run and Rise Winder Run and Rise ,? Spiral Not Allowed From 2n Story Smoke Detectors Battery Backup and Proper Location Bathroom Fixtures Proper Clearance 11 Width,36"min. drails More Than One Riser On Open Sides Railing and Guards>30"/Basement Stairs Included/Closed Risers More Than 4"in Ht. afety Glazing Notes For Required Areas Garage Fire Separation Garage Floor Sloped Attic Access Roof over 30"—22"x 30"/Crawl Spaces 18"x 24"Access Carbon Monoxide Detector Lowest Sleeping Level Soil Test Results, if required Septic To Well Or Water Line Separation All Paperwork Signed Town of Queensbury"742 Bay Road, Queensbury, 12804 Bonding & Code Enforcement Building Permit# phone:(518)761-8256 Date: - Pax: (518)745-4437 Email: codes@gaeewburynet Dear 9 t + Your bm7dmg Permit application has been reviewed and found to be deficient in the knowing are= f These det ds need to be added to or noted on both sets ofplans. Please feet f=to contact this oTwc-with any gnestnons regarding this matter. Sincerely, BUILDING&CODES OFFICE L-LS-Hemingway)Buiid'mg-YcmutFORMSIdeficient build ng pemnt:m 2003-doc r : 2y�t n O Fv "C � M cu : r � e v : r � y .. .. ... .M+'. 41 CO rv.. . .. to w ! i o r ... ! r � r : , i , r + i r r , r t r i , : I r , , P , ! I