Loading...
RC-0306-2021 Kck -J Office Use Only ADDITION/ALTERATION PERMIT Permit#: APPLICATION Permit Fee: $ 742 Bay Road,Queensbury,NY 12804 Invoice#: P:518-761-8256 www.gueensbury.net Flood Zone? Y Reviewed By: Project Location: Tax Map ID #: a Subdivision Name: 01 PROJECT INFORMATION: �U (� TYPE: -,(' Residential Commercial, Proposed Use: Single-Family —Two-Family —Multi-Family(#of units ) , —Townhouse Business Office Retail Industrial/Warehouse Garage (#of cars—) —Other(describe ) ADDITION SQUARE FOOTAGE: ALTERATION SQUARE FOOTAGE: 1st floor: 3 C*a } f4'Dw` 1st floor: �'' '�Ar 2nd floor: 2"d floor. 3rd floor: 31d floor: Basement (habitable space): Basement (habitable space): Total sq ft: - Total sq ft: Scope of work to be done: i Q D R CEOVE TALPR 272,02 TOWN OF QUEENSBURY BUILDING&CODES Addition/Alteration Application Revised January 2021 ADDITIONAL PROJECT INFORMATION: 1. Estimated Cost of Construction: $ J 2. Source of Heat (circle one):_Gas _Oil X Propane _Solar_Other Fireplaces/inserts need a separate Fuel Burning Appliances & Chimney Application 3. Are there any structures not shown on the plot plan? YES X NO Explain: 4.' Are there any easements on the property? )C YES NO SITE INFORMATION: • Is=this a corner lot? YES NO • Will the grade be changed as a result of the construction? _YES X NO • What is the water source? _PUBLIC PRIVATE WELL • What type of wastewater system is on the parcel? SEWER PRIVATE SEPTIC DECLARATION: 1. 1 acknowledge that no construction shall be commenced'prior to the issuance=of a valid permit and will be completed within a 12 month period.Any changes to the approved plans prior to/during construction will require the submittal of amended plans,additional reviews and re-approval. 2. If,for any reason,the building permit application is withdrawn,30%of the fee is retained by the Town of Queensbury.After 1 year from the initial application date, 100%of the fee is retained. 3. If the work is not completed by the 1 year expiration date the permit may be renewed, subject to fees and department approval. 4. 1 certify that the application, plans and supporting materials are a true and a complete statement and/or description of the work proposed,that all work will be performed in accordance with the NYS Building Codes;'local building laws and ordinances, and in conformance with local zoning regulations. 5. 1 acknowledge that prior to occupying the facilities proposed I, or my agents, will obtain a certificate of occupancy. 6. 1 also understand that I/we are required to.provide an as-built survey by.a_.licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy: f I have read and agree to the above: PRINTNAME: SIGNATURE: / wl DATE: Addition/Alteration Application Revised January 2021 Residential Plan Review: 1- and 2- Family Dwellings Y/N/NA (1 of 2) Two (2) full sets of plans Over 1,500 sq. ft. requires engineering stamp Design loads on plans: 115 Wind Floor Loads 40 psf (North of Rte. 149 60) 50 Ground Snow Load Sleeping Areas &Attics 30 psf "CS Calculations Decks 40 psf Wind design for lake front properties �—Q S Light and vent room schedule Window schedule with glass size & main doors/Air leakage < .5 cfm for doors, < .3 cfm for windows/Tempered glass in bathrooms Door schedule/Main entrance 36" door N — Emergency Escape or Bedrooms & Habitable Space Nli4 Above-grade: 5.7 sq. ft. &/1A. Grade: 5.0 sq. ft. ,ilk 24" (h) x 20" (w) minimum n/ 44" maximum height above door A/ Window control devices 24" or less 2nd story or 72" above grade Egress window from basement 5.0 sq. ft. Floor system sizing per table 502.3.1 11-c,.r Residential check ERI or Prescriptive method c-j All foam plastic on foundation & crawl space covered by 15 minute thermal barrier Driveway length: 300' or more-12' width required/500' or more, turnaround required Foundation drainage on plans, if required 6" drop in 10' exterior grade Framing cross section for each roof line, vertical fire stopping every 10' where required/joist spans pg. 127 Ice &snow shield —24" from exterior wall eubbe-r- �S Platforms at exterior doors &AS41 ^j �Q, Stairway headroom 6'8"; all stairs 36" wi Stair run and rise Winder run and rise Spiral stairs meet requirements ff J& Smoke detectors—battery backup & proper location, interconnected Heat detectors in attached garages—as of 4/1/2021 Bathroom fixtures—proper clearance Hall width-36" width Handrails more than four risers on open sides �t- Railing &guards > 30"/basement stairs included/closed risers more than 4" in height n�l LIA Safety glazing notes for required areas Garage fire separation: %" gable end/5/8" under living space &%" on walls/20 min. door and closer Residential Plan Review Revised March 2021 Residential Plan Review: 1- and 2- Family Dwellings Y/N/NA (2 of 2) Garage floor sloped Attic access: gasket seal & R-value equal to roof insulation Roof over 30"—22" x 30"/Crawl spaces 18" x 24" access �� Carbon Monoxide detector outside lowest sleeping area, on every level & interconnected Al within 15' of sleeping area Soil test results, if required d Septic to well or water line separation S All paperwork signed �S Note on plans energy saving light bulbs 75% Blower door test agency paperwork Floodplain Permit required —check map: 2 feet above flood elevation � Hurricane clips required Floors less than 2 x 10 covered by%" gypsum or 5/8" wood panel pi A Manuals S &J required for heating system. Cold air return hard piped „r Separate room for draft HVAC or hot water heater with fresh air HRV shown and calculations S Baffles at eaves for insulations and knee walls Makeup air for range hood >400 cfm ,./ Continuous header for garage doors to end wall/3" nailing pattern/strapping Chimney rain cap shown for fireplaces Deck hold down shown not less than 4 lags and bolts per table 507.2 Residential Plan Review Revised March 2021 Generated by REScheck-Web Software Compliance Certificate Project Wallace.Residence -Studio Addition ] Energy Code: 2018 IECC Location: Glens Palls; New York 1 Construction Type: Single=family Project Type: Addition FILE COPY Climate Zone: 6 (7635 HDD) OF Permit Date: Permit Number: Construction Site: Owner/Agent: Designer/Contractor.- 12 Reardon Road Margaret Wallace Gary McCoola Queensbury,NY 12804 12 Reardon Road Gary McCoola,Architect,PLLC Queensbury, NY 12801 3 Broad Street-3rd Floor 518-793-4853 Glens Falls, NY 12801 margaretw63@gmail.com mtcooia-.Prchitect@msn.com I'l. UAtrade-off Compliance: 22.1%Better Than Code Maximum UA: 66 Your UA: 58 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-of tV It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home.. (EWE D F O R ENERGY CODE COMPLIANCE Envelope Assemblies Gross Area cavity Cont. Perimeter Ceiling: Flat Ceiling or Scissor Truss I` 367 39.0 10.0 0.023 8 Wall:Wood Frame,16"o.c.. A l 145 20.0 5.0 0.044 6 Window: Other P � � G`_2 155 20.0 5.0 0.044 3 Wall 1:Wood Frame, 16 o.c. _ Door:Solid Door(under 50%glazing) TC1NN OF QUEENASia'JR`( 50 - 0.200 10 Window 1:-Other BUILDING&CODES_,. 33 0.280 9 Floor:Slab-On-Grade (Unheated) 38 10.0 0.480 18 Insulation depth:4.0' Compliance Statement: The proposed building design described here is consistent with the building plans;specifications;and other calculations submitted with the permit application.The proposed building ha been designed to meet the 2018 IECC requirements in REScheck Version:REScheck-Web and to comply with the mandatory requ' ments l�isfeed in the.REScheck Inspection Checklist. Name-Title - Signaebre Dat 289.7-1-48 RC-0306-2021 Wallace, Margaret 12 Reardon Rd Residential Addition 367 s.f. Project Title: Wallace Residence-Studio Addition Report date: 08/05/20 Data filename: Page l of 9 REScheck Software Version : REScheck-Web Inspection Checklist Energy Code: 2018 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. S ti d" �V r' i ie d e if ed.Pl'a�ii e ified F e oritir' rit"s'Ass� ti ns• ;• #: R'r. lns`action/Pin„Review Cori;pli s. C /. .Um' p - 'Value Value. �; 103.1 'Construction drawings and u:,l:; ;,4;i ?<l;,.. - . ,,;:' Complies 103.2 idocumentation demonstrate Does Not [PRlenergy )1 code comPlianceforthe E]Not Observable buildin e.Thermal 9 envelo ''u::`n';•; `' ''$' ^-,F P ONot Applicable envelope represented on t.} ,'r. construction documents. I �;_ 103.1, 'Construction drawings and i ti-" ' : .n.,r a,• LJComplies 103.2, documentation demonstrate E]DoesNot 403.7 energy code compliance for ' ; ? .'° [PR3]1 'lighting and mechanical systems. >• ;�; ;�;, y:� - []Not Observable rr (''t%+; C]Not Applicable 1 :Systems serving multiple •;%, >' Awelling units must demonstrate .compliance with the IECC ,;';.• ;,,y ',. Commercial Provisions. - ,,,., 3 , x..::;,:..;; eating and cooling equipment is, Heating: Heating:' ❑Complies H A> k7 ;•1�sized per ACCA Manual S based Btuihr Btu/hr Does Not ion loads calculated per ACCA Cooling: Cooling: 9: E)Not Observable ' Manual J or other methods r u '•a < ONot Applicable Btu/h Bt /hr z,• approved by the code official: Additional Comments/Assumptions: 1 High Impact(Tier 1) 2? Medium Impact(TierLow Impact(Tier 3) Project Title: Wallace Residence- Studio Addition Report date: 08/05/20 Data filename: Page 2 of 9 402.1.2 'Slab edge insulation R-value. R- R- .[]Complies See the Envelope Assemblies [FO111 Unheated Unheated E]Does Not Jable for values. E] Heated E] Heated EINot Observable T]Not Applicable 402-.1.2 :Slab edge insulation ft ft :[]Complies :See the Envelope Assemblies [F0311 'depth/length. table for values. EINot Observable []Not Applicable oco -z..EINot Applicable Snow-and ice-melting system lies controls installed. El Does Not ',,E]Not Observable Not Applicable AdditiomaUCommmamts/Assommp@mms: 1 High Impact(Tier 1) pact(Tier 2T 3 Low Impact(Tier 3) Project Title: Wallace Residence ' Studio Addition Report date: 08/05/30 Datafi|ename: Page 3of 9 ;.Value:,, �ip Ud"' 402.1.1, Door U-factor. U_ U_ DComplies See the Envelope Assemblies 402.3.4 CDoes Not table for values. (FRI]1 C]Not Observable ONot Applicable ................ .................. ...... .............- 402.1.1, :Glazing U-factor(area-weighted U_ U_ DComplies See the Envelope Assemblies 402.3.1, average), ZIDoes Not table for values. 402.3.3, 402.5 :E]Not Observable JFR2J1 EINot Applicable 303.13 U-factors of fenestration products ��,.;�i",`C]Corri plies [FR4]1 e determined in accordance W []Does Not :with the NFRC test procedure or :taken from the default table. E]Not Observable ,`1'X,?,E1Not Applicable 402.4.1.1 iAir barrier and thermal barrier Complies [FR23]1 'installed per manufacturer's s jl 0Does Not instructions. EDNot Observable 'rt..�"E]Not Applicable 402.4.3 :Fenestration that is not site built ElComplies [FR20]1 ;is listed and labeled as meeting Not AAMA/WDMA/CSA 101/1,S.2/A440 "ONot Observable !or has infiltration rates per NFRC ' ,400 that do not exceed code ONot Applicable limits. es 'ElComplies IC-rated recessed lighting fixtur sealed at housing/interior ish Does Not and labeled to indicate :s2.0 cfm J-]Not Obser ble va leakage at 75 Pa, Not Applicable 403.3.1 ;Su pply and return ducts in attics Ejcomplies _ii;[FR12]1 !insulated >=R-8 where duct is El Does Not 3 inches in diameter and >= ::CINot Observable R-6 where< 3 inches.Supply and :return ducts in other portions of EINot Applicable ::the building insulated >= R-6 for ..........., ;diameter>= 3 inches and R-4.2 .for< 3 inches in diamet er, 403.3.2 Ducts, air handlers and filter 'nComplies [FR13]1 !boxes are sealed with i!;,'.E)Does Not joints/seams compliant with E]Not Observable International Mechanical Code or �NVL Applicable 'International Residential Code, :applicable. Building cavities are not used as av, OComplies ducts E]Does Not or plenums. Observable C]Not Applicable piping conveying fluids R- R- ElComplies 4 0 1 4�,�,, il�,;H V A C F )above 105 QF or chilled fluids E]Does Not ...",ibelow 55 QF are insulated to ?R []Not Observable 3. :DNot Applicable 403.4.1 Protection of insulation on HVAC omplies [FR2411 piping. -]EDo es Not �:-'.,E]Not Observable IN ot Applicable insulated to R- R- UComplies Hot water pipes are insu ?R.3. ElDoes Not UNot Observable ENot Applicable 1 High Impact(Tier 1) J .,,2;]Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Wallace Residence - Studio Addition Report date: 08/05120 Data filename: Page 4 of 9 - r�,r«.:.#, rr• rti�t�r ,', ."ou�M,,. " #' .,�. ,a "I-1<Uer�€i `>< :�:� ��- I s ;�,� ",;,Automatic or gravity dampersare`rr°a,,,, z � `r+ i,EComplies L+.t1 �g3m�-,;installed on all outdoor air '��;� tiq� ,�•`air 411y< ,,~ti �mtakes and exhausts. - � ! � , , Does Not •r�?k. �< -w' ^ �,�,• _ .,: `. r,;_"❑Not't:;,< Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) LowIm ct(Tier 3)Medium Impact(Tier 2) Project Title: Wallace Residence-Studio Addition Report date: 08/05/20 Data filename: Page 5 of 9 r in der tei, •ii )ar Plans Uerifi''d. F�e1d::V r ,, � y .$• ,,; .'- ,,� Ua'Itte�; ':,F; :,Co�pli�5 Co�nrnEtti�s/�ssYirrr •eons 3 ' ' AII installed insulation is labeled $ r t �f ' 4 t; st "k ',, f e ' ❑Complies $] ,�or the installed R-values �,", ❑Does Not ``'i• �s�t<'.;.F�provided. '�z..'=y�' : : � >�, ;,,+z; _ ' r `ir, n2 " 'f❑Not Observable ❑Not Applicable ; 402.1.1, ;Wall insulation R-value. If this is a R- R ❑Complies ;See the EnvelopeAssemblres 402.2.5, ;mass wall with at least 1/2 of the ❑ Wood ❑ Wood ❑Does Not ;table for values. 402.2.6 ;wall insulation on the wall [IN3]1 :exterior,the exterior insulation ❑ Mass ❑ Mass :[]Not Observable :requirement applies (FR10). ❑ Steel ❑ Steel ❑Not Applicable ; 303.2 :Wall insulation is installed per %` '=°'r:;10'z1: `.❑Com lies instructions. ❑D [IN4]1 manufacturer's ., p r oes Not :7 ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) Medium Impact(Tier 2) $„ Low Impact(Tier 3) --ir—' _ Project Title: Wallace Residence-Studio Addition Report date: 08/05/20 Data filename: Page 6 of 9 � ' - ' 402.1.1, ;Ceiling insulation R-value, R- R- ;E]Complies :See the Envelope Assemblies 402.2.1, Jable for values. 402.2.2, Steel Steel 402.2.6 Observable 303.1.1.1,'Ceiling insulation installed per 303.2 ::manufacturer's instructions. [F1211 insulation marked every :300 ft2. -]Not Observable KII ot Applicable ',.,,,Vented attics with air permeable Complies insulation include baffle adjacent to soffit and eave vents that Does Not Not Observable extends over insulation. Not Applicable 402.2.4 'Attic access hatch and door R- R- OComplies :adjacent assembly. 'FINot Observable F_]Not Observable ONot Applicable F12711 !,determine air leakage with Tt2— ft2 :'E]Does Not ,either: Rough-in test:Total :E]Not Observable ileakage measured with a :E]Not Applicable ipressure differential of 0.1 inch ;w.g.across the system including ,;the manufacturer's air handier ::enclosure if installed at time of itest,Postconstruction test:Total ,leakage measured with a ;pressure differential of 0.1 inch ;:w.g.across the entire system including the manufacturer's air handler enclosure. 'E]Does Not -Eests,verification_may need to E]Not Applicable ::Occur during Framing Inspection. 403.3.2.1 !Air handier leakage designated [F124]1 :by manufacturer at<=2-/o or ­-ElDoes Not ;design air flow. E]Not Observable E]Not Applicable DComplies -for control of primary if heating and cooling systems an initially set by manufacturer to 4- code specifications. 6 Heat pump thermostat installed 11 on heat pumps. Not Observable ONot Applicable Circulating service hot water systems have automatic or iaccessible manual controls. Not `LJNot Applicable ' Project Title: Wallace Residence' Studio Addition Report date: 08/05/20 Data M|enanne: Page 7 of 9 i Plans Verified Heid Verified insgect!on R,rdvrs�ons: Value Vaiue Caiimplie! ments/ Ssucllpt gCis:; !ie tlb, ` �� �<l alns not part of tested system t W ❑Com hies „-,, d and listed ' ' n { err " , ❑ p ,,- i2$ f r 2r ., " � Does Not HVAC equipment meet efficacy ;f' ' 'c„ A s and airflow limits per Table ' ❑Not Observable R403.6.1. n, ;,s ;❑Not Applicable 40 'r2, Hot water boilers sup I i -- --` ---'---" PP Y ng heat ! ? „ ❑Com lies t16� , '•:;through one or two-pipe heating ❑ ; i : Does Not systems have outdoor setback :.•-: Not Observable:c `;,...1''" - ='❑ able r.� ontrol to lower boiler water :1�' - �•` ht., '+❑N of Applicable I etemperature based on outdoor �,- ."".g�. _"..'.';'p" ....r ..:rat:;i;,� r•:.�'+���. -�.._.,�__.y n:i tedHeawater circulationsystems t`G'C41S`'SY,t+;"+ra: .#,:Y;:>~•i%°F h.''r.;F..st•,SdL'yc';''a+:'...;.r.;,:.1.,`."—,a• iT„'.:�;;,i`.•a?':>.�..'r::r ❑Complies r ,Shave a circulation pump.The ? , ❑ ,system return pipe is a dedicated Does Not return pipe or a cold water supply ' r ❑Not Observable i pipe.Gravity and thermos- ❑Not Applicable hsystems �s on circulate -:, Yp on are not present. Controls for circulating hot waters stem "s pumps start the pum Pwith signal - ape for hot water demand within theoccupanc „ automatically Controls lly turn-off the pump 'r .�gY when water is in circulation loop a. ;.$*k ,is at set-point temperature and no demand for hot water exists ! `5•xks Electric heat traces stems y ❑Complies ,comply with IEEE 515.1 or UL ' ❑Does Not =515.Controls automatically ;adjust the energyinput to the Not Observable P "•3:�;, -�:,' ;❑Not Applicable tracing to maintain the z•.;••�•• ;i•:3�°<}desired water temperature in the ZRI�..:rxx,Y, .y1.`q, '''4:.r.'i: ;Demand recirculation water 5 ' ❑Complies systems have controls that �,r '? �'' s� ' v - r^ ❑Does Not rrwn , a;manage operation of the pump "z{, , gand limit the temperature of the s 'i„ ❑Not Observable a water entering the cold water ❑Not Applicable *' 3<`;xpiping to<= 1042F. Drain water heat recovery units :4 a a'tr,.,,,k <'.z; :❑Complies :tested in accordance with CSA �'i;- �3i; Does Not c- B55. �',: x`+ 1. Potable water-side�;, de J.'s; ?>,•r> pressure loss of drain water heat _ ❑Not Observable t ❑Not Applicable recovery units psi for individual units connected to one VrO,`l 'or two showers. Potable water- side`� `� er :side pressure e loss of drain water .rheat recovery <ery units 2 psi for F ,l;a;';•�!: 'ea;. .fit:: indivdual units connected to - 8. three ee or more showers, 404.1 ;90%or more of permanent ❑Complies L. , t [FI611 :fixtures have high efficacy �':❑Does Not P rz '�- J' r,• d l , []Not Observable `.'..:. ...,;:.: ❑Not Applicable 404:1-,1,: ;Fuel as lighting systems have ':;r,: : '' "'" ,.:, 9 9 9 Y '�?�?�'--„ .{� �.,,;,: ::a'�>t`❑Complies 'F12 .no continuous i �,,:.,�i`� "': - '`'t=.� ' uous pilot light. ❑ !==' Does Not y;` .+a', ,, ``a:�';•PX:,��„xi:: ❑Not Observable ,jig.;. .r.3. .,i;.�i":i'l`.e'' ,'}�i'SSnt3•%, a�;.,;.,.. ❑Not Applicable 1�:e.C;[!'';;{;$"i'sa,:a?t{;7i.5.L :.'n, 's e r„c.::,,s',,�;r .— ��w','-w Compliance certificate posted. ";, ,, 'Srs„z,'g t,.`"" �:..a;.:+,`..:y:s,.. P P ,;;4 r ';5� .,i�.:j i�,y:� "�F.i:;.-?fir::-5?>�i'."�' c,y'.:": ❑COm piles .;., .�,�,6;..3,:',T` w�,k;��•��,,*,.s.ry:?<�r{;,��r,';';• �t�'+�,�: :.t...,;;,'; ��5�"i❑Does Not , ❑Not Observable []NotApplicable 1 High Impact (Tier 1) 2,. Medium Impact(Tier 2) 3 Low Impact(Tier 3) _ _____....__.____...W__.....--------,---........L_.�_�__— 1 Project Title: Wallace Residence -Studio Addition Report date: 08/05/20 Data filename: Page 8 of 9 f � � ii.i'. rr'r ►y i � ttl" t at SIO�* P. y t Co t3 `{ bm' �. a a „ r.; �'tT3+33e.,r Manufacturer manuals for �Gr,..:},�s , ��,{s�;t p�,74,` ; `h>r ,�,;� spCompliesJ :mechanical and water heating u,;. y,;. ,i.. uz„ :U ::i :=,w:, s ,;,,,.., ,,} 1 systems have been provided. c ! t Does Not � rI x .0Not Observable Applicable Additional Comments/Assumptions: 1_ High Impact(Tier 1) ;: ; Medium Impact(Tier 2) 3?: Low Impact(Tier 3) Project Title: Wallace Residence - Studio Addition Report date: 08/05/20 Data filename: Page 9 of 9 � 6 A( 201E IECC Energy I Efficiency Certificate Insulation Rating R-Value Above-Grade Wall 25.00 Below-Grade Wall 0.00 Floor 10.00 Ceiling/Roof 49.00 Ductwork (unconditioned spaces): Glass&Door Rating . Window 0.28 Door 0.20 CoolingHeating& Heating System: Cooling System: Water Heater: Name: Date: Comments V , .� Number 374 ' `Originally Issued: 01/16/2015 Revised: 01/28/2021 Valid Through: 01/31/2022 SES FOAM,LLC 2.5 The contractors that will be installing the insulations 4008 Louetta Road,#5385' a~n�"'�-sk be certified by SES Foam,LLC. Spring,Texas 77388 www.sesfoam.com a of the insulation in areas of"very heavy" termite NEXSEALTM 2.0 AND NEXS TM DEC 7 2®21 s ation shall be in accordance with 2018 and 2015 IBC t on 2603.8, 2012 IBC Section 2603.9, or 2009 IBC SPRAY FOAM INSULATIO S BU v p tr C�UEE�S c ion 2603.8,or IRC Section 318.4,as applicable. CSI Section: NO& CODE'.3 Y 2. The insulations at a V/8-inch (41.3 min) thickness or 07 2100 Thermal Insulation . ater are Class II vapor retarders as defined in Section 1.0 RECOGNITION R202 of the IRC and Section 202 of the IECC. NexsealTM 2.0 and NexsealTM 2.0 LE Spray Foam Insulations 2.8 Labeling and jobsite certification of the insulation and recognized in this report have been evaluated for use as spray coatings shall comply with 2018 and 2015 IRC 1101.10 and foam insulation complying with IBC Section 2603, IRC 1101.10.1.1, 2012 IRC Sections 1101.12 and 1101.12.1, Section R316, 2018, 2015 and 2012 IECC Sections C303, 2009 IRC Sections N1101.4 and N1101.4.1,IECC Sections C402,R303 and R402 and 2009 IECC Sections 303 and 402. C303.1.1 and C303.1.2,as applicable. The following code editions are recognized: 2.9 The insulations produced at SES Foam,LLC,located in • 2018, 2015, 2012 and 2009 International Building St.Louis,Missouri shall be under a quality control program Code®(IBC) with inspections by Quality Control Consultants,LLC. • 2018,2015,2012 and 2009 International Residential Code®(IRC) 3.0 PRODUCT USE • 2018, 2015, 2012 and 2009 International Energy Conservation Code®(IECC) 3.1 General:When installed in accordance with Section 3.3 • 2017 Florida Building Code, Building (FBC, of this report, NexsealTM 2.0 and NexsealTM 2.0 LE Spray Building),2017 Florida Building Code,Residential Foam Insulations may be used in wall cavities, floor (FBC,Residential)and 2017 Florida Building Code, assemblies or ceiling assemblies, and in attic and crawl Energy(FBC,Energy)-supplement attached. spaces as nonstructural thermal insulation material. The spray-applied foam plastic insulations are used in Type V-B 2.0 LIMITATIONS construction under the IBC and in dwellings under the IRC. The spray-applied foam plastic Insulations also may be used Use of NexsealTM 2.0 and NexsealTM 2.0 LE Spray Foam in Type I, II, III or IV construction when installed in Insulations recognized in this report is subject to the accordance with Section 3.5 of this report. following limitations: NexsealTM 2.0 and NexsealTM 2.0 LE Spray Foam 2.1 The insulations shall be installed in accordance with the Insulations may be used as air impermeable insulations manufacturer's published installation instructions.They shall when installed in accordance with Section 3.2.4 of this also be installed in accordance to this evaluation report and report. the applicable code,and if there are any conflicts between the manufacturer's published installation instructions and this 3.2 Design: report,the more restrictive governs. 3.2.1 General.NexsealTM 2.0 and NexsealTM 2.0 LE Spray 2.2 Except as indicated in Section 3.3.3 of this report or by Foam Insulations shall comply with requirements in 2018, the applicable code, the insulations shall be separated from 2015 and 2012 IECC Sections C402.1 and R402, or 2009 the interior of the building by a code approved thermal IECC Section 402,as applicable. barrier. 3.2.2 Thermal Resistance.(R-Values): NexsealTM 2.0 and 2.3 As noted in Sections 3.3.3 and 3.3.4 of this report,the NexsealTM 2.0 LE Spray Foam Insulations have a thermal insulations shall not exceed the nominal density and resistance(R-Value)at a mean temperature of 75°F(24°C) thickness. as shown in Table 1 of this report. 2.4 During installation the insulations and the surfaces to which they are applied shall be protected from exposure to weather. The product described in this Uniform Evaluation Service(UES)Report has been evaluated as an alternative material,design or method of construction in order to satisfy and comply with(N7� the intent of the provision of the code,as noted in this report,and for at least equivalence to that prescribed in the code in quality,strength,effectiveness,fire resistance,durability and safely, as applicable,in accordance with IBC Section 104.11.This document shall only be reproduced in its entirety. Copyright©2021 by International Association of Plumbing and Mechanical Officials.All rights reserved.Printed in the United States. Ph:1-877-41ESRPT•Fax:909.472.4171 web:www.uniforrn-es.org•4755 East Philadelphia Street,Ontario,California 91761-2816-USA In) ao�cmas Porn 4 of R hoauct Ccrtllkatbn eaav ql 1 • - -374 Originally Issued: 01/16/2015 Revised: 01/28/2021 Valid Through: 01/31/2022 Table 1-Thermal Resistance (R-Value) 55-gallon (208L) drums. When stored in factory-sealed (°F•ft2•h/Btu) containers at temperatures between 50°F(10 °C) and 80°F (27°C),the coating has a shelf life of 24 months. Thickness NexseaTM 2.0 and (inch) NexseaTM 2.0 LE 3.3 Installation: 1 7.2 3.3.1 General. The manufacturer's published installation instructions for NexsealTM 2.0 and NexsealTM 2.0 LE Spray Foam Insulation and this report shall be available on the 3 21 jobsite during installation for quality control purposes. 2 4 28 NexsealTM 2.0 and NexsealTM 2.0 LE Spray Foam Insulations 5 35 shall be spray-applied on the jobsite using a volumetric 42 positive displacement pump in accordance with the manufacturer's published installation instructions. The --� 7 49 applied insulation shall be sprayed in multiple passes having a maximum thickness of 2 inches (50.8 mm) per pass for 9 64 NexsealTM 2.0 and 4 inches (50.8 mm) per pass for 10 71 NexsealTM2.0 LE up to the maximum insulation thickness specified in this report.The maximum in-service temperature 11 78 for all areas shall not exceed 180°F(82°C).The spray-applied 12 84 foam plastic insulation shall not be used in electrical outlets For SI: 1 inch=25.4 mm,I°F•ft2-h/Btu=0.176 110 K•mz/W. Or junction boxes or in continuous contact with rain or water. 'R-Values are calculated based on tested K values at 1-inch and 3.5- The spray-applied foam plastic insulation shall be sprayed inch thicknesses. onto a substrate that is protected and clean from any debris or 2 R-Values greater than 10 are rounded to the nearest whole number. weather related conditions during application. 3.2.3 Surface Burning Characteristics. At a maximum 3.3.2 Installation with a Prescriptive Thermal Barrier: thickness of 4 inches(102 mm)and a nominal density of 2.0 NexsealTM 2.0 and NexsealTM 2.0 LE Spray Foam Insulations pcf(32 kg/m'), the NexsealTM 2.0 and NexsealTM 2.0 LE shall be separated from the interior by an approved thermal Spray Foam Insulations have a flame spread index of 25 or barrier of minimum '/z inch thick (12.7 mm) gypsum less and smoke-developed index of 450 or less when tested wallboard or an equivalent thermal barrier.When installed in in accordance with ASTM E84.Thicknesses are not limited accordance with this section the spray foam may be any for ceiling cavities and wall cavities when covered by a code thickness when installed behind a prescriptive thermal complying prescriptive thermal barrier, such as minimum barrier. The barrier shall comply with, and be installed in '/2-inch thick(12.7 mm)gypsum board. accordance with IBC Section 2603.4 or IRC Section R316.4, as applicable. 3.2.4 Air Permeability. When tested in accordance with ASTM E2178 at a minimum thickness of 1 inch(25.4 mm), 3.3.3 Installation with an Alternative Thermal Barrier NexsealTM 2.0 and NexsealTM2.0 LE Spray Foam Assembly: The thermal barrier required by IBC Section Insulations are classified as air-impermeable insulations in 2603.4 or IRC Section R316.4 may be omitted when all of accordance with Section 1202.3 of the 2018 IBC, Section the following apply: 1203.3 of the 2015 IBC, and Section R806.5 of the 2018, 2015 and 2012 IRC or Section R806.4 of the 2009 IRC, as a. The thickness of NexsealTM 2.0 and NexsealTM applicable. 2.0 LE Spray Foam Insulations shall not exceed 5'/2 inches (140 mm) on walls and other vertical 3.2.5 Vapor Permeance: When tested in accordance with surfaces and 10`/4 inches(260 mm)on ceilings and the ASTM E96 desiccant method(Procedure A),NexsealTM other horizontal and overhead surfaces;and 2.0 and NexsealTM 2.0 LE Spray Foam Insulations have a b.The NexsealTM 2.0 and NexsealTM 2.0 LE Spray vapor permeance of less than 1.0 perms [57.4 x 10-1 Foam Insulations are coated with a minimum 14 g/(Pa•s•m2)], at a minimum thickness of V/a inches (41.3 mils (0.36 mm) wet film thickness (9 mils [0.23 mm)and qualify as a Class II vapor retarder in accordance mm.] dry film thickness)of DC315 Fireproof Paint with IBC Section 202 and IRC Section R202. intumescent coating as described in Section 3.2.6 of this report. The coating shall be applied in 3.2.6 DC315 Fireproof Paint. DC315 Fireproof Paint, accordance with the coating manufacturer's recognized in ER-499, is a water-based latex intumescent instructions and this report. Surfaces to be coated coating manufactured by International Fireproof shall be dry,clean and free of dirt,loose debris and Technology,Inc. and is supplied in 5 gallon(19L)pails and other contaminants that could impact adhesion of the coating. Page 2 of 6 r ' q , , r • - 374 Originally Issued: 01/16/2015 Revised: 01/28/2021 Valid Through: 01/31/2022 3.3.4 Installation for Attics and Crawl Spaces: When space, and the thickness of the NexsealTM 2.0 and used in an attic or crawl space where entry is made only for NexsealTM 2.0 LE Spray Foam Insulation does not exceed service of utilities, NexsealTM 2.0 and NexsealTM 2.0 LE 11'/2 inches(292 mm.),and when applied to vertical surfaces Spray Foam Insulations shall be installed in accordance with the maximum thickness does not exceed 7'/2 inches (190 this section. The insulation shall be separated from the mm),the NexsealTM 2.0 and NexsealTM 2.0 LE Spray Foam interior of the building by an approved thermal barrier as Insulation do not require the application of either an ignition described in Sections 3.3.2 and 3.3.3 of this report, as barrier or a fire protective coating. applicable. Optional: If desired,NexsealTM 2.0 and NexsealTM 2.0 LE 3.3.4.1 Installation with a Prescriptive Ignition Barrier: Spray Foam Insulation may be coated with 4 mils(0.1 mm) Where entry is made only for the service of utilities, wet film thickness (2.7 mils dry film thickness [0.07 mm]) NexsealTM 2.0 and NexsealTM 2.0 LE Spray Foam of DC315 Fireproof Paint as described in Section 3.2.6. Insulations may be installed within attics or crawl spaces with an ignition barrier in accordance with 3.4.2.3 Unvented Attics: NexsealTM 2.0 and NexsealTM 2.0 LE Spray Foam Insulation may be installed in unvented attic IBC Section 2603.4.1.6, or IRC Sections R316.5.3 and assemblies and unvented enclosed rafter assemblies in R316.5.4, as applicable. The ignition barrier shall be accordance with Section 1202.3 of the 2018 IBC, Section installed in a manner such that the foam plastic insulation is 1203.3 of the 2015 IBC or Section R806.5 of the 2018,2015 not exposed,and is consistent with the requirements of the and 2012 IRC, or Section R806.4 of the 2009 IRC, as type of construction required by the applicable code. applicable. 3.3.4.2 Installation with an Alternative Ignition Barrier 3.5 Exterior Walls of Buildings of Type I, II, III or IV Assembly: When installation is in accordance with this Construction. When NexsealTM 2.0 and NexsealTM 2.0 LE section,the ignition barrier specified by Section 2603.4.1.6 Spray Foam Insulations are used in exterior walls of of the IBC or Sections R316.5.3 and R316.5.4 of the IRC, buildings of Type I, II, III or IV construction of any height as applicable,may be omitted. the insulation shall comply with Section 2603.5 of the IBC and this section. NexsealTM 2.0 and NexsealTM 2.0 LE Spray 3.3.4.2.1 General: When NexsealTM 2.0 and NexsealTM 2.0 Foam insulation shall be installed at a maximum thickness LE Spray Foam Insulations are installed in attics and crawl of 4-inches(102 nun). spaces without a prescriptive ignition barrier,the following 3.5.1 Complying Exterior Wall Assemblies. Wall conditions apply: a. The thickness of the foam plastic insulation applied assemblies that comply with Section 2603.5_of the IBC and underside of the top of the space shall not this report that may be used in exterior walls of buildings of to the u mm). Type I,II,III or IV construction of any height are described exceed inches(the b. The thickness of the foam plastic insulation applied in Table 2 of this report. to the vertical surfaces shall not exceed 7'/2 inches 4.0 PRODUCT DESCRIPTION (190 m). NexsealTM 2.0 and NexsealTM 2.0 LE Spray Foam c. Entry is only to service utilities in the attic or crawl Insulations are a spray-applied, polyurethane foam plastic space and no storage is permitted. and comply as medium-density insulation in accordance d. Attic or crawl space areas cannot be interconnected. with Section 3.1.1 and Table 1 of AC377.The insulation is e. Air from the attic or crawl space cannot be a two-component spray foam plastic with a nominal in-place circulated to other parts of the building. density of 2.0 pcf(32 kg/m3). f. In accordance with IBC Section 1203.2 or IRC Section R806, as applicable, attic ventilation is The spray-applied insulation is mixed in the field by provided,as applicable. combining a polymeric isocyanate(A component)and a resin g. In accordance with IBC Section 1203.3 or IRC blend(B component).The liquid components shall be stored Section R408.1, as applicable, crawl-space in 55-gallon(208 L)drums at temperatures between 50OF and ventilation is provided,as applicable. 70°F(10°C and 21°C).When Component A and Component h. In accordance with IMC (International Mechanical B are stored in factory-sealed containers at the recommended Code®)Section 701,combustion air is provided. temperatures,the maximum shelf life is six months. 3.3.4.2.2 Attics and Crawl Spaces: NexsealTM 2.0 and NexsealTM 2.0 LE Spray Foam Insulations may be spray- applied in attics to the underside of roof sheathing, roof rafters and/or vertical surfaces, and in crawl spaces to the underside of floors and/or vertical surfaces as described in this section. When applied to the underside of the top of the Page 3 of 6 N �eEVALUATION REPORT374 S o Originally Issued: 01/16/2016 Revised: 01/28/2021 Valid Through: 01/31/2022 5.0 IDENTIFICATION 7.0 STATEMENT OF RECOGNITION The spray foam insulation containers are identified with the This evaluation report describes the results of research following: carried out by IAPMO Uniform Evaluation Service on SES a. Manufacturer's name(SES Foam,LLC) Foam's NexsealTM 2.0 and NexsealTM 2.0 LE Spray Foam b. address and telephone number, - Insulations to assess conformance to the codes shown in c. the product trade name (NexsealTM 2.0 or NexsealTM 2.0 Section 1.0 of this report,and serves as documentation of the LE Spray Foam Insulation) product certification. Products are manufactured at the d. use instructions location noted in Section 2.9 of this report under a quality e. density,flame-spread and smoke-development indices control program with periodic inspection under the f, date of manufacture or batch/run number supervision of IAPMO UES. g. the IAPMO Uniform ES evaluation report number (ER- 374)and Mark of Conformity ) h. the name or logo of the inspection agency(Quality Control �/z`°-'- v Consultants,LLC) Brian Gerber,P.E.,S.E. Each container of the DC315 Fireproof paint is labeled Vice President,Technical Operations with the manufacturer's name (International Fireproof Uniform Evaluation Service Technology,Inc.),the product name,and use instructions. Either Mark of Conformitymay be used as shown below: Y Richard Beck,PE,CBO,MCP Vice President,Uniform Evaluation Service 1ApM UE C/� 0 S GP Russ Y ES CEO,The IAPMO Group For additional information about this evaluation report please visit www.uniform-es.ore or email us at info()uniform-es.org or IAPMO UES ER-374 6.0 SUBSTANTIATING DATA 6.1 Data in accordance with the ICC-ES Acceptance Criteria for Spray-applied Foam Plastic Insulation, AC377, dated April 2016, including reports of tests in accordance with Appendix X of AC377. 6.2 Reports of room comer testing in accordance with NFPA 286. 6.3 Reports of fire characteristics testing in accordance with NFPA 285. 6.4 Reports of potential heat of building material testing in accordance with NFPA 259. 6.5 Reports of water vapor transmission testing in accordance with ASTM E96. Page 4 of 6 CESO ' . -Originally Issued: 01/16/2015 Revised: 01/28/2021 Valid Through: 01/31/2022 Table 2—NFPA 285 Complying Exterior Wall Assemblies Wall Component Material Description Base Wall System(BWS) 1—concrete wall Use either 1,2 or 3 2—concrete masonry wall 3—1 layer Of'/8-inch thick Type X gypsum wallboard installed on the interior side of minimum 35/8-inch-deep minimum No.20-gauge thick steel studs spaced a maximum or 24 inches on center.Lateral bracing installed minimum every 4 feet vertically or as requited. Wall stud cavities shall be filed at each floor line with minimum 4 pcf density mineral wool(e.g.Thermafiber friction fit between steel wall studs. Resilient Channel Double-leg `hat' shaped steel resilient channel, minimum 30 gage, installed when used with BWS 3 above perpendicular to the wall studs (interior side only) and spaced a maximum of 24- inches on center between steel studs and Type X gypsum wallboard.Entire perimeter of window opening to be framed with resilient channel. Perimeter Fire Barrier System Perimeter fire barrier system complying with Section 715.4 of the 2012 IBC shall be installed,as applicable,to fill the void created at the intersection of the exterior curtain wall assembly and the concrete floor slab. Interior Insulation 1—None Use either 1 2 3 4 or 5• or 2—Maximum 35/8-inch thickness of EasySeal.S(Sucrasea10.5)applied to the interior combination of and 4;or combination surface of BWS 1 or 2 above.''4 of 3 and 5 3—EasySeal.S lb. (Sucraseal 0.5)applied to the full depth of the wall stud cavity, or less,with exterior gypsum sheathing(see BWS 3 above)as the substrate covering the width of the cavity and the inside of the steel wall stud framing flange.4 4—Fiberglass batt insulation(faced or unfaced) 5—Mineral wool insulation faced or unfaced Exterior Sheathing 1—None(for BWS 1 or 2 above) Use either 1,2 or 3 2-'/2 inch thick exterior gypsum sheathing(for BWS 3 above) 3—5/8-inch-thick Type X exterior type gypsum sheathing for BWS 3 above Exterior Insulation Maximum 4-inch thick NexsealTM 2.0 and NexsealTM 2.0 LE Spray Foam Insulation 3 Exterior Wall Covering2 1 — Brick - steel brick veneer anchors, installed a maximum 24-inches on-center, Use either 1,2,3,4 or 5 vertically on each stud with maximum 2-inch air gap between exterior insulation and brick.Brick to be standard nominal 4-inch thick clay brick installed in a running bond pattern using Type S mortar. 2 — Stucco - minimum 3/4-inch thick, exterior cement plaster and lath. A secondary water-resistive barrier(WRB) shall be installed between the exterior insulation and the lath. The Secondary WRB shall not be full-coverage asphalt or butyl-based self- adhering membranes. 3=Minimum 2-inch thick natural stone.Joints shall be mortared(non-open jointed). 4—Minimum 1'/z-inch thick concrete masonry unit,pre-cast concrete or artificial cast stone.Joints shall be mortared. 5—Minimum 1'/4-inch thick terra cotta.Joints shall be mortared. Flashing of windows, doors or other As an option, flash around windows, doors and other exterior wall penetrations with exterior wall penetrations limited amounts of maximum 12-inch wide flashing tape (acrylic, asphalt or butyl- based)or liquid-applied membrane material with or without fiber mesh reinforcement. SI: 1 inch=24.4 min: 1 pcf=16.0 kg/m3; I BTU/ft2=0.01128 mJ/m2 1Fireblocking per Section 718 of the 2018,2015 and 2012 IBC and Section 717 of the 2009 IBC and thermal barrier material requirements per Section 2603.4 of the IBC shall be met for Base Wall Systems 1 and 2, as required by specific wall construction details when a combustible concealed space is created on interior side of exterior wall assembly. 2 Exterior wall coverings shall be installed in accordance with the manufacturer's installation instructions and shall comply with the provisions of Chapter 14 of the IBC and Chapter 7 of the IRC,as applicable. 3 The potential heat of 4-inch-thick NexsealTM 2.0 and NexsealTM 2.0 LE Spray Foam Insulation is 2,066 Btu/ft2 per inch of thickness when tested in accordance with NFPA 259. 4 The potential heat of V/s-inch-thick SES 0.5 lb.Spray Foam Insulation is 466 Btu/ft2 per inch of thickness when tested in accordance with NFPA 259. Page 5 of 6 ve • - y374 Originally Issued: 01/16/2015 Revised: 01/28/2021 Valid Through: 01/31/2022 FLORIDA SUPPLEMENT 4408 Louetta Road,#538 Spring,Texas 77388 www.sesfoam.com NEXSEALTM 2.0 AND NEXSEALTM 2.0 LE SPRAY FOAM INSULATION CSI Section: 07 2100 Thermal Insulation 1.0 RECOGNITION NexsealTM 2.0 and NexsealTM 2.0 LE Spray Foam Insulations evaluated in IAPMO UES Evaluation Report ER-374 are satisfactory alternative to the following codes and regulations: • 2017 Florida Building Code,Building(FBC, Building) • 2017 Florida Building Code,Residential(FBC, Residential) • 2017 Florida Building Code,Energy(FBC, Energy) 2.0 LIMITATIONS 2.1 The clearance between the foam insulation installed above grade and exposed earth shall be in accordance with Section 2603.8 of the FBC, Building or Section R318.8 of the FBC,Residential,as applicable. 2.2 Verification shall be provided that a quality assurance agency audits the manufacturers quality assurance program and audits the production quality of products,in accordance with Section (5)(d) of Florida Rule 61G20-3.008. The quality assurance agency shall be approved by the Commission(or the building official when the report holder does not possess an approval by the Commission). For additional information about this evaluation report please visit www.uniform-es.ore or email at infoQuniform-es.ore Page 6 of 6