2003-886 TOWYOF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
'Community Development-Building&Codes (518)761.8256
R, IFICATE',.,,OF. OCCUPANCY
Perrin Number. : P2003:08$6 Date Issued...., Ffiday,November 19,2004
r =This:i's,m certify that work requested:tu be done as shown by Permit Number P200 0g$
-has been completed..
Tax Map Number:. , 523400.297-008-0001-023-000-0000
559 QUEENSBURY_Ave
. Zocatson: -
Owner: - SMS ENTERPRISES,'LLC
Applicant: MONAKAN METALS
This structure may be occupied as a:
By Order of Town Board
Commercial Alteration TOWN OF QUEENSBURY
Director of Building&Code Enforcement
TOWN OF QLTEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development-Building&Codes (518)761-8256
BUILDING PERMIT
Permit Number: P20030886 Application Number: A20030886
Tax Map No: 523400-297-008-0001-023-600-0000
Permission is hereby granted to: MONAHAN WTALS
For property located at: 559 QUEENSBURY Ave
in the Town of Queensbury,to construct or place
at the above location in accordance with-application together with plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. Tyne of Construction Value
Owner Address: SMS ENTERPRISES, LLC
559 QUEENSBURY Ave Commercial Alteration $8,000.00
Total Value $8,000.00
QUEENSBURY,NY 12804-0000
Contractor or Builder's Name/Address Electrical Inspection Agency
Plans&Specifications
2003-886 MONAHAN METALS
NEW TRUCK DOOR AS PER APPLICATION
$50.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Sunday; October 24, 2004
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at the To o eensb F ' a , October 24, 2003
SIGNED BY for the Town of Queensbury.
Director of Building&Code Enforcement
Building Permit'Application.
Town of Queensbury—Dept of Community Development,742 Hay Road,Queensbury,NY
(518)761-8256
A permit must be obtained before beginning construction. Permit File No.03
No inspection will be made until applicant has received a Fee paid $ O
valid building permit. All applicants' spaces on this Rec.Fee Paid $�
application must be completed and must appear on the Reviewed 8
- application form. y
Applicant:\ del Owner: ��� Y`?Yit'1't G•J
Address: C mac//--.il.��'. Address•
Phone#(— #(5!
Property Location: Lot Number: / House Number
Subdivision Name: Tax Map Numben-a q_
o New Building: residence /commercial 'Estimated Market Value of Construction: $
a Addition: residence/ commercial esidence If an Addition,what will use of new addition be?
teratio r / erciai
a No change to exterior size: fesidence/
a Other work(describe VWla
Check Oeeupancylnformation 1' Floor 2" Floor Other floor Total
Below sq.ft. sq.ft. sq.ft. Square Feet
o Single family dwelling
o Two Pamily dwelling
a Townhouse
a Multifamily dwelling
#of units
a Office
a Mercantile
o Manufacturin
o I car detached garage
- a 2 car detached garage
0 3 car detached garage
0 1 car attached garage
a 2 car attached garage
a 3 car attached garage
a Storage building-
commercial
a Storage building-
residential
a Other
What is the proposed height of the structure feet inches
Will any second-hand or ungraded lumber be used? If so,for what?
Type of Heating System: electric/ oil % gas/wood /forced hot air/ .baseboard/other:
Number of Flrevlace-s to be installed Number of Woodstoves to be installed
List below the person(s)responsible for supervision of work as regards to building codes:
Name Address Phone Number
Builder
Plumber
Mason
Electrician
Declaration: please sign below after you have carefully read the statement:
To the best of my knowledge the statements contained in this application,together with the.plans and specifications
submitted,are a true and complete statement of all proposed work to be done on the described premises and that all
Provisions of the Building Code,the Zoning Ordinance and all other laws pertaining to the proposed work shall be complied
with,whether specified or noted,and that such work is authorized by the-owner. Further,it is understood that Uwe shall
submit,prior to a Certificate of Occupancy or Certificate of Compliance being issued,as requested by the Zoning
Administr r or Dir for of Building and Codes,an As Buffe Survey by a licensed surveyor;drawn to scale,showing actual
location new nstruction.
Si 17A '— owner,owner's agent,architect,contractor
Commercial Final Inspection Report
Office No.: (518)761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: am/p Depart: pm
742 Bay Road,Queensbury,NY 12804 Inspector's lnitials:�
NAME: PERMIT#: —AW
LOCATION: 45-5.-' 05 A0K Z1116- DATE, eelif M!�
COACqENTS:
Y N NA
Chimney/"B"Vent/Direct Vent Location L
Plumbing Vent Through Roof 6"/Roof Complete 7
Exterior Finish Grade Complete 6"in 10' or Equivalent
Interior/Exterior Guardrails 42 in.Platform/Decks
Interior/Exterior Ballisters 4 in. Spacing Platform/Decks
Stair Handrail 34 in.—38 in./Step Risers 7"/Treads 11"
Vestibules For Exit doors>3000 sq. ft.
All Doors 36 in.w/Lever Handles/Panic Hardware,if required
Exits At Grade Or Platform 36 (w)x 44"(1)/Canopy or Equiv.
Gas Valve Shut-off Expos d&Regulator(18")Above Grade
Floor Bathroom Watertight/Other Floors Okay
Relief Valve,Heat Trap/Water Temp.110 Degrees Maximum
Boiler/Furnace Enclosure 1 In% or Fire Extinguishing System
Fresh Air Supply for Occupancy/Ventilation Combustion
Low Water Shut Off For Boilers
Gas Furnace Shut Off Within 30 ft, or Within Line Of Site
Oil*Furnace Shut Off at Entrance to Furnace Area
Stockroom/Storage/Receiving/Shipping Room(2 hr.), I V2doors
> 10%> 1000 sq.ft.
3/411our Corridor Doors&Closers
Firewalls Fire Separation,2 Hour, 3 Hour Complete/Fire
Dampers Fire Doors
Ceiling Fire Stopping, 3,000 sq. ft.Wood Frame
Attic Access 30"x 20"x 30"(h),Crawl Space Access 18"x 24"
Smoke Vents Or Fan,if required
Elevator Operation and Signage/Shaft Sealed
Handicapped Bathroom Grab Bars/Sinks/Toilets
Handicapped Bath/Parking Lot Signage
Public Toilet Room Handicapped Accessible
Handicapped Service Counters, 34 in., Checkout 36"
Handicapped Ramp/Handrails Continuous/12 in.Beyond
Active Listening System and Signage Assembly Space
Final Electrical
Site Plan/Variance required
Final Survey,New Structure Flood Plain certification,
As-built Septic System Layout Required or On File
Building Number or Tenant Address on Building or Driveway
Water Fountain or Cooler I
Building Access All Sides by 20' /Driveable Surface 201 wide
Okay To Issue Temp. or Permanent C/O
Okay To Issue C/C
Last printed 6/3/2003 9:27 AML:\Pa:nW\Suild1ng&Codes\Cornwerclal Final Inspection Report.doc
�- I I A-,4->Nr,\ vim, 1l /d�l
Queensbury Building & Cade Enforcement - Residential Final lnspec o
Office No. (518)761-8256 Arrive: any/ n• Dppart)
Date Inspection request received: Inspector's Initial
NAME: - IT##:
LOCATION: , DATE:
TYPE OF STRUCTURE- --
Comments
Y N N/A
Chimney Ht./"B"Vent/Direct Vent Location
Fresh Air Intake
3 inch Plumb Vent through roof minimum 6"
Roof Complete/Exterior Finish Co m lete
Guard 30 in.or more @ stairs,decks,patios
Guard at stairwell at 34 in. or more
Guard at deck,porches 36 in.or more
Exterior Finish Complete
Interior/Exterior Railings 34 in.to 38 in.
Platform at altexterior doors
Interior Handrails stairs 2 or more risers
Enclosed Stairs Sheetrock Underside minimum '/"
Gypsum
Grade awa •from foundation 6 in. with 10 ft.
Handrail Termination at Newell Post or Wall
6 inch clearance to sill plate
Gas Valve shut-off exposed/regulator 18"above grade
Gas Furnace shut-off within 30 ft. or within line of site
Oil Furnace shut-off at entrance to furnace area
Furnace/Hot Water Heater operating
Low water shut-off boiler
Relief Valves installed/Heat Trap/Water Temp 110
Interior privacy/trim/doors/main entrance 36 in.
Bathroom/Kitchen watertight
Safety glazing/Window in stairwells safety glazing
Interior Smoke Detectors:
Every level: / Every Bedroom:
Outside every bedroom area:
Inter Connected: / Battery backup:
Carbon Monoxide Detector
Bathroom Fans, if no window
Plumbing fixtures
Foundation insulation
Floor truss, draft stopping finished basement 1,000 sf
Emergency egress below grade
Basement stairs closed rise>4 inches
Gara e Floor Pitched
Garage fireproofing/'/4 hour fire door/door closer
Duct work Sealed properly
Gas Logs in Sealed or Glass Enclosure
Attic access 34 in.x 22 in.x 30 in.(ht.)In accessible area
Crawl Spaces 18"x 24"access, 1 s . ft.-150 s .ft. vents
Building No./Address visible from road
Final Electrical
Site Plan /Variance required
Final Survey Plot Plan
As Built Septic System/Sewer Dept,Inspection Sticker
Flood Plain Certificatio r uired
Okay to issue C/C - C/0 jaemporary/Permanent]
L:\PamW\Building&CodesUnspection Forms\Res. Final Insp.form 2.docLast printed 2/12/04
2Ol : r
r memo ��d
p
k ZNth 0
Pr'laS eY p,'1��ice mm�� �y� w
t �, masgzMHX! "
m
a 7
x ,12 Poor F,XO,')17 G, �wl. m
�,,td•u. � � � � S1G - 2, Q � bt N
t ► � U o
(r?/v/l
t, fit
1' C
of
"a
o '
Oct 21 03 12: 46p schoder rivers associates , 668-2919 p. 3
SCHODER RIVERS PROJECT TITIZ DRAWING NO.
CHASSOCIA TES 4"?
CONSULTING ENGINEERS, P.C. SHEET THE
2315-2 Route ON )'ke
Lake George, New York 12845 -
T. (518) 668-2918 Pro]- 3- m
F., (518) 668-2919 Drown
te t oe
(:7 e-
5; T
I-M
X4 U,
4v
-Z
— New
>e
Typ-
q., $CHODER RIVERS PROJECT TmEMONAHAN METALS DRAWING NO.
'YI ASSOCIATES
CONSULTING ENGINEERS, P.C. SHEET THE ��. TRUCK DOOR FRAME
2315-2 -Route 9N SK-2
Lake George, New York 12845
T. 518) 668-2918 Proj..No.. pjg_37¢ DoM: 1�1-14-1�3 saute: As Noted
F- r518) 668-2919 Drown 811 yr SAIR Chk ey: Modiffm Dw9. No.:
1 .
8" YSK
W16x45
REINFORCE .BLOCK CELL CLOSEST
TO DOOR WCONT TO
C 12x2 .7 FOOTING &/FI L#VOID W/GROUT.
h
>� 1/8" THK. x6" LG. STRAP
N N ANCHORS @ 16" C—C (TYP.)
c� 12" C.M.U. WALL
2
SK-2
TYPICAL 7RUCK DOCK DOOR FRAME
N.T.S.
2" 2"
3 SIDES
----I 1/4
12" C.M.U. C 12
WALL j
t L4x4x 1/4 x 8" LG.
W16
C12— tti r ►
' � r: ie ' i -� •b
• e e (2} 1/2"0 EXP. BOLTS
4 4". MIN. EMBEDMENT.
1/4 2"-12" CONC. WALL
SEC770N . SEC770N 2
1 1/2"=1 —r- SK-2 SK-2
t¢�,SCHODER RIVERS pRaEcr TITLEONAHAN META
16f'7,0',SSOCIATES LS DRAWING NO.
CONSULTING ENGINEERS, -P.C: SHEET ME
2315-2 Route 9N NOTES
Lake George, New:York 12845" Seale: NONE `
�5
T'. (51.8) 668-2918 P-j. No.c 03-37•b Date:, tk1-14-03
F. (518) 668-29.19 Dmwn. tly SMR 6k By. Atodtt7ee Dwq. No.:
GENERAL' NOTES
1. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND
ELEVATIONS OF: EXISTING STRUCTURAL ELEMENTS AND .FACILITIES.
INSTALLATION" SEQUENCE
1. : INSTALL- NEW "CMU INFILL TO':DIMENSIONS REQUIRED.
2. INSTALL TEMPORARY SHORING AND NEEDLE BEAMS.,, JACK NEED LE BEAMS -TIGHT
TO EXISTING MASONRY.
3. REMOVE MASONRY BELOW NEEDLE BEAMS-AND INSTALL NEW LINTEL AND DOOR~'FRAME.
INSTAL MASONRY AROUND NEW LINTEL BEAM AND .DOOR FRAME AND REMOVE
TEMPORARY SHORING.
CONCRETE MASONRY. NOTES
1. ARCHITECTURAL MASONRY UNITS SHALL COMPLY WITH .ASTM C 90, WITH
AN AVERAGE NET COMPRESSIVE "STRENGTH OF 3500 psi 'MINIMUM. UNITS
SHALL BE PRODUCED WITH A 'LIQUID'` POLYMERIC,. INTEGRAL WATER
REPELLENT ADMIXTURE. ADMIXTURE SHALL BE "DRY— BLOCK' A'S
MANUFACTURED BY W.R:. GRACE,-& CO. -OR EQUIVALENT.
-2. MORTAR SHALL COMPLY WITH ASTM C270,•„TYPE N.
3. REINFORCEMENT SHALL CONFORM TO ASTM ,A615, GRADE 60. INSTALL-
REINFORCEMENT IN ACCORDANCE WITH ASCE 6-951ACI 530.1�95, SECTION 3.4.
STEEL NOTES
1. FABRICATE AND ERECT ALL- STEEL IN ACCORDANCE WITH THE AMERICAN
INSTITUTE OF STEEL CONSTRUCTION CODE OF STANDARD.PRACTICE FOR
STEEL BUILDINGS AND BRIDGES. ' LATEST EDI TI:ON.
2. MATERIAL REQUIREMENTS FOR VARIOUS STEEL SHAPES ARE AS'.. .
FOLLOWS.
3. ' ALL WIDE FLANGE SHAPES--.- ASTM A992, GR. •50
TUBE STEEL — ASTMA500, GR. B
PIPES. .— ASTM A53
MISC. ;PLATES AND ANGLES — ASTM A36
4.• ANCHOR: BOLTS SHALL CONFORM -TO ASTM ,A30X
5. WELDING SHALL BE- IN CONFORMANCE, WITH. THE LATEST AW_S CODE.
WELDING ELECTRODES SHALL -CONFORM °.TQ E70 SERIES.•
6. . ALL STRUCTURAL STEEL SHALL- BE PREPARED IN ACCORDANCE WITH
SSPC—SP3 POWER TOOL CLEANING. ALL STEEL-SHALL BE SHOP COATED
WITH ONE COAT, 2 =- 3 mils D.F.T. ALKYD PRIMER./FINISH , CARBOLINE
MULTI—BOND 150 OR EQUIVALENT. TOP COAT IN THE FIELD .WITH ONE
COAT OF-HIGH QUALITY ALKYD .ENAMEL-"PER .OWNER'S. INSTRUCTIONS