2003-886 TOWYOF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 'Community Development-Building&Codes (518)761.8256 R, IFICATE',.,,OF. OCCUPANCY Perrin Number. : P2003:08$6 Date Issued...., Ffiday,November 19,2004 r =This:i's,m certify that work requested:tu be done as shown by Permit Number P200 0g$ -has been completed.. Tax Map Number:. , 523400.297-008-0001-023-000-0000 559 QUEENSBURY_Ave . Zocatson: - Owner: - SMS ENTERPRISES,'LLC Applicant: MONAKAN METALS This structure may be occupied as a: By Order of Town Board Commercial Alteration TOWN OF QUEENSBURY Director of Building&Code Enforcement TOWN OF QLTEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building&Codes (518)761-8256 BUILDING PERMIT Permit Number: P20030886 Application Number: A20030886 Tax Map No: 523400-297-008-0001-023-600-0000 Permission is hereby granted to: MONAHAN WTALS For property located at: 559 QUEENSBURY Ave in the Town of Queensbury,to construct or place at the above location in accordance with-application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Tyne of Construction Value Owner Address: SMS ENTERPRISES, LLC 559 QUEENSBURY Ave Commercial Alteration $8,000.00 Total Value $8,000.00 QUEENSBURY,NY 12804-0000 Contractor or Builder's Name/Address Electrical Inspection Agency Plans&Specifications 2003-886 MONAHAN METALS NEW TRUCK DOOR AS PER APPLICATION $50.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Sunday; October 24, 2004 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the To o eensb F ' a , October 24, 2003 SIGNED BY for the Town of Queensbury. Director of Building&Code Enforcement Building Permit'Application. Town of Queensbury—Dept of Community Development,742 Hay Road,Queensbury,NY (518)761-8256 A permit must be obtained before beginning construction. Permit File No.03 No inspection will be made until applicant has received a Fee paid $ O valid building permit. All applicants' spaces on this Rec.Fee Paid $� application must be completed and must appear on the Reviewed 8 - application form. y Applicant:\ del Owner: ��� Y`?Yit'1't G•J Address: C mac//--.il.��'. Address• Phone#(— #(5! Property Location: Lot Number: / House Number Subdivision Name: Tax Map Numben-a q_ o New Building: residence /commercial 'Estimated Market Value of Construction: $ a Addition: residence/ commercial esidence If an Addition,what will use of new addition be? teratio r / erciai a No change to exterior size: fesidence/ a Other work(describe VWla Check Oeeupancylnformation 1' Floor 2" Floor Other floor Total Below sq.ft. sq.ft. sq.ft. Square Feet o Single family dwelling o Two Pamily dwelling a Townhouse a Multifamily dwelling #of units a Office a Mercantile o Manufacturin o I car detached garage - a 2 car detached garage 0 3 car detached garage 0 1 car attached garage a 2 car attached garage a 3 car attached garage a Storage building- commercial a Storage building- residential a Other What is the proposed height of the structure feet inches Will any second-hand or ungraded lumber be used? If so,for what? Type of Heating System: electric/ oil % gas/wood /forced hot air/ .baseboard/other: Number of Flrevlace-s to be installed Number of Woodstoves to be installed List below the person(s)responsible for supervision of work as regards to building codes: Name Address Phone Number Builder Plumber Mason Electrician Declaration: please sign below after you have carefully read the statement: To the best of my knowledge the statements contained in this application,together with the.plans and specifications submitted,are a true and complete statement of all proposed work to be done on the described premises and that all Provisions of the Building Code,the Zoning Ordinance and all other laws pertaining to the proposed work shall be complied with,whether specified or noted,and that such work is authorized by the-owner. Further,it is understood that Uwe shall submit,prior to a Certificate of Occupancy or Certificate of Compliance being issued,as requested by the Zoning Administr r or Dir for of Building and Codes,an As Buffe Survey by a licensed surveyor;drawn to scale,showing actual location new nstruction. Si 17A '— owner,owner's agent,architect,contractor Commercial Final Inspection Report Office No.: (518)761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/p Depart: pm 742 Bay Road,Queensbury,NY 12804 Inspector's lnitials:� NAME: PERMIT#: —AW LOCATION: 45-5.-' 05 A0K Z1116- DATE, eelif M!� COACqENTS: Y N NA Chimney/"B"Vent/Direct Vent Location L Plumbing Vent Through Roof 6"/Roof Complete 7 Exterior Finish Grade Complete 6"in 10' or Equivalent Interior/Exterior Guardrails 42 in.Platform/Decks Interior/Exterior Ballisters 4 in. Spacing Platform/Decks Stair Handrail 34 in.—38 in./Step Risers 7"/Treads 11" Vestibules For Exit doors>3000 sq. ft. All Doors 36 in.w/Lever Handles/Panic Hardware,if required Exits At Grade Or Platform 36 (w)x 44"(1)/Canopy or Equiv. Gas Valve Shut-off Expos d&Regulator(18")Above Grade Floor Bathroom Watertight/Other Floors Okay Relief Valve,Heat Trap/Water Temp.110 Degrees Maximum Boiler/Furnace Enclosure 1 In% or Fire Extinguishing System Fresh Air Supply for Occupancy/Ventilation Combustion Low Water Shut Off For Boilers Gas Furnace Shut Off Within 30 ft, or Within Line Of Site Oil*Furnace Shut Off at Entrance to Furnace Area Stockroom/Storage/Receiving/Shipping Room(2 hr.), I V2doors > 10%> 1000 sq.ft. 3/411our Corridor Doors&Closers Firewalls Fire Separation,2 Hour, 3 Hour Complete/Fire Dampers Fire Doors Ceiling Fire Stopping, 3,000 sq. ft.Wood Frame Attic Access 30"x 20"x 30"(h),Crawl Space Access 18"x 24" Smoke Vents Or Fan,if required Elevator Operation and Signage/Shaft Sealed Handicapped Bathroom Grab Bars/Sinks/Toilets Handicapped Bath/Parking Lot Signage Public Toilet Room Handicapped Accessible Handicapped Service Counters, 34 in., Checkout 36" Handicapped Ramp/Handrails Continuous/12 in.Beyond Active Listening System and Signage Assembly Space Final Electrical Site Plan/Variance required Final Survey,New Structure Flood Plain certification, As-built Septic System Layout Required or On File Building Number or Tenant Address on Building or Driveway Water Fountain or Cooler I Building Access All Sides by 20' /Driveable Surface 201 wide Okay To Issue Temp. or Permanent C/O Okay To Issue C/C Last printed 6/3/2003 9:27 AML:\Pa:nW\Suild1ng&Codes\Cornwerclal Final Inspection Report.doc �- I I A-,4->Nr,\ vim, 1l /d�l Queensbury Building & Cade Enforcement - Residential Final lnspec o Office No. (518)761-8256 Arrive: any/ n• Dppart) Date Inspection request received: Inspector's Initial NAME: - IT##: LOCATION: , DATE: TYPE OF STRUCTURE- -- Comments Y N N/A Chimney Ht./"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumb Vent through roof minimum 6" Roof Complete/Exterior Finish Co m lete Guard 30 in.or more @ stairs,decks,patios Guard at stairwell at 34 in. or more Guard at deck,porches 36 in.or more Exterior Finish Complete Interior/Exterior Railings 34 in.to 38 in. Platform at altexterior doors Interior Handrails stairs 2 or more risers Enclosed Stairs Sheetrock Underside minimum '/" Gypsum Grade awa •from foundation 6 in. with 10 ft. Handrail Termination at Newell Post or Wall 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18"above grade Gas Furnace shut-off within 30 ft. or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 Interior privacy/trim/doors/main entrance 36 in. Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: / Every Bedroom: Outside every bedroom area: Inter Connected: / Battery backup: Carbon Monoxide Detector Bathroom Fans, if no window Plumbing fixtures Foundation insulation Floor truss, draft stopping finished basement 1,000 sf Emergency egress below grade Basement stairs closed rise>4 inches Gara e Floor Pitched Garage fireproofing/'/4 hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Attic access 34 in.x 22 in.x 30 in.(ht.)In accessible area Crawl Spaces 18"x 24"access, 1 s . ft.-150 s .ft. vents Building No./Address visible from road Final Electrical Site Plan /Variance required Final Survey Plot Plan As Built Septic System/Sewer Dept,Inspection Sticker Flood Plain Certificatio r uired Okay to issue C/C - C/0 jaemporary/Permanent] L:\PamW\Building&CodesUnspection Forms\Res. Final Insp.form 2.docLast printed 2/12/04 2Ol : r r memo ��d p k ZNth 0 Pr'laS eY p,'1��ice mm�� �y� w t �, masgzMHX! " m a 7 x ,12 Poor F,XO,')17 G, �wl. m �,,td•u. � � � � S1G - 2, Q � bt N t ► � U o (r?/v/l t, fit 1' C of "a o ' Oct 21 03 12: 46p schoder rivers associates , 668-2919 p. 3 SCHODER RIVERS PROJECT TITIZ DRAWING NO. CHASSOCIA TES 4"? CONSULTING ENGINEERS, P.C. SHEET THE 2315-2 Route ON )'ke Lake George, New York 12845 - T. (518) 668-2918 Pro]- 3- m F., (518) 668-2919 Drown te t oe (:7 e- 5; T I-M X4 U, 4v -Z — New >e Typ- q., $CHODER RIVERS PROJECT TmEMONAHAN METALS DRAWING NO. 'YI ASSOCIATES CONSULTING ENGINEERS, P.C. SHEET THE ��. TRUCK DOOR FRAME 2315-2 -Route 9N SK-2 Lake George, New York 12845 T. 518) 668-2918 Proj..No.. pjg_37¢ DoM: 1�1-14-1�3 saute: As Noted F- r518) 668-2919 Drown 811 yr SAIR Chk ey: Modiffm Dw9. No.: 1 . 8" YSK W16x45 REINFORCE .BLOCK CELL CLOSEST TO DOOR WCONT TO C 12x2 .7 FOOTING &/FI L#VOID W/GROUT. h >� 1/8" THK. x6" LG. STRAP N N ANCHORS @ 16" C—C (TYP.) c� 12" C.M.U. WALL 2 SK-2 TYPICAL 7RUCK DOCK DOOR FRAME N.T.S. 2" 2" 3 SIDES ----I 1/4 12" C.M.U. C 12 WALL j t L4x4x 1/4 x 8" LG. W16 C12— tti r ► ' � r: ie ' i -� •b • e e (2} 1/2"0 EXP. BOLTS 4 4". MIN. EMBEDMENT. 1/4 2"-12" CONC. WALL SEC770N . SEC770N 2 1 1/2"=1 —r- SK-2 SK-2 t¢�,SCHODER RIVERS pRaEcr TITLEONAHAN META 16f'7,0',SSOCIATES LS DRAWING NO. CONSULTING ENGINEERS, -P.C: SHEET ME 2315-2 Route 9N NOTES Lake George, New:York 12845" Seale: NONE ` �5 T'. (51.8) 668-2918 P-j. No.c 03-37•b Date:, tk1-14-03 F. (518) 668-29.19 Dmwn. tly SMR 6k By. Atodtt7ee Dwq. No.: GENERAL' NOTES 1. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND ELEVATIONS OF: EXISTING STRUCTURAL ELEMENTS AND .FACILITIES. INSTALLATION" SEQUENCE 1. : INSTALL- NEW "CMU INFILL TO':DIMENSIONS REQUIRED. 2. INSTALL TEMPORARY SHORING AND NEEDLE BEAMS.,, JACK NEED LE BEAMS -TIGHT TO EXISTING MASONRY. 3. REMOVE MASONRY BELOW NEEDLE BEAMS-AND INSTALL NEW LINTEL AND DOOR~'FRAME. INSTAL MASONRY AROUND NEW LINTEL BEAM AND .DOOR FRAME AND REMOVE TEMPORARY SHORING. CONCRETE MASONRY. NOTES 1. ARCHITECTURAL MASONRY UNITS SHALL COMPLY WITH .ASTM C 90, WITH AN AVERAGE NET COMPRESSIVE "STRENGTH OF 3500 psi 'MINIMUM. UNITS SHALL BE PRODUCED WITH A 'LIQUID'` POLYMERIC,. INTEGRAL WATER REPELLENT ADMIXTURE. ADMIXTURE SHALL BE "DRY— BLOCK' A'S MANUFACTURED BY W.R:. GRACE,-& CO. -OR EQUIVALENT. -2. MORTAR SHALL COMPLY WITH ASTM C270,•„TYPE N. 3. REINFORCEMENT SHALL CONFORM TO ASTM ,A615, GRADE 60. INSTALL- REINFORCEMENT IN ACCORDANCE WITH ASCE 6-951ACI 530.1�95, SECTION 3.4. STEEL NOTES 1. FABRICATE AND ERECT ALL- STEEL IN ACCORDANCE WITH THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION CODE OF STANDARD.PRACTICE FOR STEEL BUILDINGS AND BRIDGES. ' LATEST EDI TI:ON. 2. MATERIAL REQUIREMENTS FOR VARIOUS STEEL SHAPES ARE AS'.. . FOLLOWS. 3. ' ALL WIDE FLANGE SHAPES--.- ASTM A992, GR. •50 TUBE STEEL — ASTMA500, GR. B PIPES. .— ASTM A53 MISC. ;PLATES AND ANGLES — ASTM A36 4.• ANCHOR: BOLTS SHALL CONFORM -TO ASTM ,A30X 5. WELDING SHALL BE- IN CONFORMANCE, WITH. THE LATEST AW_S CODE. WELDING ELECTRODES SHALL -CONFORM °.TQ E70 SERIES.• 6. . ALL STRUCTURAL STEEL SHALL- BE PREPARED IN ACCORDANCE WITH SSPC—SP3 POWER TOOL CLEANING. ALL STEEL-SHALL BE SHOP COATED WITH ONE COAT, 2 =- 3 mils D.F.T. ALKYD PRIMER./FINISH , CARBOLINE MULTI—BOND 150 OR EQUIVALENT. TOP COAT IN THE FIELD .WITH ONE COAT OF-HIGH QUALITY ALKYD .ENAMEL-"PER .OWNER'S. INSTRUCTIONS