2003-910 TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development-Building&Codes (518)761-8256
CERTIFICATE 0,F OCCUPANCY
Permit Number: P20030910 Date Issued: Thursday, May.27,2004
This is,to certify that work requested to.be done as shown by Permit'Number P20030910
has been completed.
Tax Map Dumber: 523400-296-008-0001.024.002-0000
Location: 3 CHELSEA PI
Owner: MICHAELS GROUP LLC THE
Applicant: MICHAELS GROUP LLC THE
This,structure may be occupied as a:
By Order of Town Board
Garage-2 Cars Attached TOWN OF QUEENSBUEY .
Townhouse
Director of Building&Code Enforcement
TOWN' OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 -
Community Developnient-Building&' Codes (518) 761-8256
BUILDING PERMIT
Permit Number: P20030910 Application Number: A20030910
Tax Map No: 523400-296-008-0001-024-001-0000
Permission is hereby granted to: MTCT4AFI.SCROTTPTJ.CTHF.
For property located at: 3 CHELSEA P1
in the Town of Queensbury,to construct or place
at the above location in accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. Type of Construction Value
Owner Address: MICHAELS GROUP LLC THE Garage-2 Cars Attached
10 BLACKSMITH Dr Townhouse $182,900.00
MALT NY NY 12020-0000 Total Value $182,900.00
Contractor or Builder's Name Address Electrical Inspection Agency
MICHAELS GROIJP
SUITE I
10 BLACKSMITH Dr
MALTA- NY 12020
Plans&Specifications
2003-910 Lot House No. 3 CHELSEA PLACE
1674 SQ FT TOWNHOUSE WITH 2-CAR ATTACHED GARAGE AS PER.PLOT PLAN
SPECIFICATIONS
$279.36 PERMIT FEE PAID-THIS PERMIT EXPIRES: Friday,November 05,2004
(if a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queenshury before the expiration date.)
Dated at the day,November 05, 2003
SIGNED BY (T� e/707 for the Town of Queensbury.
Director of Building&Code'Enforcement
Building Permit Application
Town of Qt.icensbury-Dept of Community Development, 742 Bay Road,Queensbury,NY
(518)761-8256
A permit must be obtained before beginning Construction. Permit File No.
No inspection will be made until applicant has received a Fee Paid ,
valid building permit. All applican(s' spaces on this Rec. Fee Paid
application must be completed and must appear on the Reviewed By: _1-- ✓
application form. Z J
Applicant: \f-\��-oe Owner:
Address: Address:
Phone# (5e) Phone# �eWPJ OF p _ o
AUILDING AND Cc-
Property Location: Lot umber: ✓ / House Number ?? / C-i-IEL4SPEPN -PL.Ar_EF_
Subdivision Natne: k�. Tax Map Number: a9� • Ga'_r �f,
New Building: residence /commercial Estimated Market Value of Construction: $ I +�7- 19 00
❑ Addition: residence/ commercial If an Addition, what will use of new addition be?
❑ Alteration: residence/ commercial
❑ No change to exterior size: residence/coni'I
❑ Other work(describe )
Check Occulmneylnfortnation I" Floor 2"` Floor Ofher floor Total
Bdory sq.U. sq.ft. sit. 11. Square Feet
❑ Single family dwelling
❑ Two family dwelling
:g 'Townhouse 14to"7 2o'7 1 tc'7 4-
❑ Multifamily dwelling
##Of units
❑ Ofllce
❑ Mercantile
❑ Manufacturing
❑ I cat'detached garage
❑ 2 car detached garage
❑ 3 car detached garage
❑ 1 car attached garage
�a 2 car attached garage 45o
❑ 3 car:attached garage
❑ Storage building-
commercial
❑ Storage building- ------
residential
❑ Other
Will any second-hand or ungraded lumber be used? If so, for what?
Type of I leating System: electric/ oil / gas)wood /forced hot air/ baseboard/other:
Number of Firentaces to be installed _ Number o£WoodLstnnes to be installed
List below the person(s) responsible for supervision'of work as regards to building codes:
Name Address
- - — - -
_ P iodic Nutnl�er
Plumber QAC 3'
Mason I OSS 1 j5eVAr3, _
Electrician k_Njt ►" -. i r --
Deelaratioll: please sign below after you have earef illy read the slatentcnt.•
To tIte best of my knowledge the statements contained in this application,together with the plans and specifications
submitted,are a true and complete statement of all proposed work to be done on the described premises and that all
provisions of the Building Code,the Zoning Ordinance and all other laws pertaining to the proposed work sliall be complied
with, whedler specified or noted,and thal stick work is authorized by(lie owner. I-uriber, it is midet;stood that Uwe sliall
submit,prior to a Certificate of Occupancy or Certificate of Compliance being issued,as requested by the Zoning
Administrator or Director of Building and Codes,an As Brdlt Sur twi,by a licensed'surveyor;drawn to scale,showing actual
location of all new cotes uctiot
Signature:__ owner,owner's agent,architect,contractor
Queensbury Building & Code Enforcement - Residential Final Inspection
Office No.(518)761-8256 Arrive: am/p Dpart: am/pm
Date Inspection request received: Inspector's Initials:
NAME: G M�-e >�� PERMIT#:
LOCATION: o >, DATE: C P; -0
TYPE OF STRUCTURE:
Comments
Chimney Ht./"B"Vent/Direct Vent Location I
Fresh Air Intake
3 inch Plumb Vent through roof minimum 6"
Roof Complete/Exterior Finish Conn plete
Guard 30 in.or more @,stairs,decks,patios
Guard at stairwell at 34 in, or more
Guard at deck,porches 36 in.or more
Exterior Finish Complete
Interior/Exterior Railings 34 in. to 38 in.
Platform at all exterior doors
Interior Handrails stairs 2 or more risers
Enclosed Stairs Sheetrock Underside minimum V2"
Gypsum A
Grade away from foundation 6 in. with 10 ft. v,
Handrail Termination at Newell Post or Wall
6 inch clearance to sill plate
Gas Valve shut-off exposed/regulator 18"above grade
Gas Furnace shut-off within 30 ft. or within line of site V
Oil Furnace shut-off at entrance to furnace area
Furnace/Hot Water Heater operating
Low water shut-off boiler
Relief Valve(s)installed/Heat Trap/Water Temp 110
Interior privacy/trim/doors/main entrance 36 in.
Bathroom/Kitchen watertight
Safety glazing/Window in stairwells safety glazing
Interior Smoke Detectors:
Every level: / Every Bedroom:
Outside every bedroom area:
Inter Coribected: Battery backup:
Carbon Monoxide Detector
Bathroom Fans,if no window
Plumbing fixtures
Foundation insulation
Floor truss,draft stopping finished basement 1,000 sf
Emergency egress below grade
Basement stairs closed rise>4 inches
Garage Floor Pitched
Garage fireproofing/3/4 hour fire door/door closer
Duct work Sealed properly
Gas Logs in Sealed or Glass Enclosure
Attic access 30 in.x 22 in.x 30 in.(ht.)In accessible area
Crawl Spaces 18"x 24"access, I sq. ft.-150 sq. ft.vents
Building No./Address isibl/from roa j/
Final Electrical LZ U
Site Plan /Variance r4quirdd
Final Survey Plot Plan As Built Septic System/Sewer Dept.Inspection Sticker IS f.
-
Flood Plain Certification, if required
Okay to issue C/C or C/0[Temporary/Permanent
L:\PamW\Building&Codes\Inspection Forms\Res.Final Insp. form 2.docLast vrinted 2/12/04
Foundation Inspection Report
Office No. (5 18)761-825 6 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: am/p Depart: am/pm
742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials:
NAME: UJ PERMIT#: C;00 0
LOCATION: ' M2 J)(20 INSPECT ON: Y)Q,
TYPE OF STRUCTURE:
Comments
Y N N/A
Footings
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Foundation Dampproofing
Foundation/Waterproofing
Type of Dampproofing/Waterproofing
Footing Drain Daylight or Sump.
Footing Drain Stone:
12 inch width
6 inches above footing
-- 6 mil of for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\Sueliemingway\Building.Codes.Inspection.FORMS\Foundaflon Inspection Reportdoc January 28,2003
Rough Plumbing / Insulation Inspection Re �.Aort
Office No. (518)761-8256 Date inspection request received:
Queensbury Building&Code Enforcement Arrive: am/ Dopart: /am/prA
742 Bay Road,Queensbury,NY 12804 Inspector's Initials:
NAME: PERMIT #: C)LOO-S-Do'-Do'
q-/
?)
LOCATION: INSPECT ON:
TYPE OF STRUCTURE:
Y N N/A
PVC: R-1,R-2,R-3,R4 Drain I Vents
Cast Iron, Copper Drain/Vent 1 Comm.
Plumbing Vent/Vents in Place
Rough Plumbing/Nail Plates
I % inch min.Drain Size
Washing Machine Drain 2 inch min.
Head or Air Supply Test
Drain and Vents
5 PSI or 10 feet above highest
connection for 15 minutes
Cleanout every 100 feet/change of direction
Water Supply Piping
Cooper Commercial
Co .CPVC,Pex One and Two-Family
n�sation,l#esidential Check/Commercial Check
Pro
Properr Ve
nt,Attic Vent
Duct[Hot Water Piping Insulation
If required unheated spaces
1 Combustion Air Supply for Furnace
Duct work sealed properly No duct tape
COMMENTS:
L:\SueHemingway\Building.Codes.Inspection.FORMS\Rough Plumbing Insulation Report.doc November l7,2003
Framing/Firestopping Inspection Report
Office No. (518)761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: am/phi part _ m/pm
742 Bay Road, Queensbury,NY 12804 Inspector's Initials: 'l .: --- ---- ---
NAME: i Gh �, PERMIT#: D
LOCATION: V INSPECT ON: — F
TYPE OF STRUCTURE:
Y N N/A COMMENTS
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 3 6 in. or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 !2(w) 16 gauge(8) 16D nails each side
Draft stopping 1,000 sq. ft, floor trusses
Anchor Bolts 6 ft. or less on center
Ice and snow shield 24 inches from wall
Fire separation 1, 2,3 hour
Fire wall 2,-3 .4 hour: ,
stopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
Douse side 1/2 inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows-Habitable Space/Bedrooms
24 in.(H)
20 in. (W)
5.7 sf above!below grade
5.0 sf grade
"
LASueHemingway\Building.Codes.InspectionTORMSTraming Firestopping Inspection Report.doe January 28,2003
Rough Plumbing Insulation Inspection Report
Office No. (518)761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive:_am/JV��a
742 Bay Road, Queensbury,NY 12804 Inspector's Initials:-
NAME: ltnw-nc_�) PERMIT#: C>
LOCATION: o INSPECT ON:
TYPE OF STRUCTURE:
Y N N/A
PVC: R-1,R-2,R-3,R-4 Drain Vents 7/
Cast Iron, Copper Drain/Vent I Comm.
Plum g Vent Vents in Place
Xbugh Plumbing/Nail Plates
Head or Air Supply Test
Dfain and Vents
5 PSI or 10 ft. above highest
Connection for 15 minutes
Water Supply Piping
Copper Commercial
Copper, CPVC,Pex One &Two Family
Insulation/Residential Check/Commercial Check
Proper Vent,Attic Vent
Duct/Hot Water Pip mig insulation
If required unheated spaces
Combustion Air Supply for Furnace
.Duct Work Sealed Properly
COMMENTS:
-L:\SueHemingway\]3uilding.Codes.Inspeefion.FORMS\Rough Plumbing Insulation Report.doe January 28,2003
Rough Plumbing / Insulation Inspection Report
Office No. (518)761-8256 Date Inspection request received: /tA
Queensbury Building&Code Enforcement Arrive:-am/pm e art: am/pm
742 Bay Road,Queensbury,NY 12804 Inspector's Initials:
NAME: �i ���.LA9 PERMIT#:
LOCATION: INSPECT ON:
TYPE OF STRUCTURE:
N N/A
PVC: R-1,R-2,R-3,R-4 Drain Vents
Cast Iron,Copper Drain/Vent Comm.
IUM>
dG Vent Vents in Place
t� ugh Plumbing/Nail Plates
Head or Air Supply Test
Drain and Vents
5 PSI or 10 ft.above highest
Connection for 15 minutes
Water Supply Piping
Copper Commercial
Copper, CPVC,Pex One &Two Family
Insulation/Residential Check/Commercial Check
Proper Vent,Attic Vent
Duct/Hot Water Piping Insulation
If required unheated spaces
Combustion Air Supply for Furnace
Duct Work Sealed Properly
COMMENTS:
L:\SucHemingwaylBuildina,.Codes.Inspection.FORMS\Rough Plumbing Insulation Report.doc January 28,2003
Framing / Firestopping Inspection Report
Office No. (518)761-8256 Date Inspection request received: C1
Queensbury Building&Code Enforcement Arrive: a :>epart: m
742 Bay Road, Queensbury,NY 12804 Inspector's Initials---
NAME: Z/� ?� j PERMIT#: r l
LOCATION: INSPECT ON: 3-b 6
TYPE OF STRUCTURE:
Y N 'N/A COMMENTS
Framing .
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 12(w) 16 gauge(8) 16D nails each side
Draft stopping 1,000 sq. ft, floor trusses
Anchor ft. or less on center
Ice and snow- h 4 inches from wall
Fire separation 1,2,3 hour
Fire wall,2, 3,4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side '/z inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above I below grade
5.0 sf grade
L:1SueHemingway\Building.Codes,lnspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003
Framing / Firestopping Inspection Report
Office No. (518)761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: am/ Depart: ain/pm
742 Bay Road, Queensbury,NY 1.2804 Inspector's Initials:
NAME: 1 CL19 PERMIT#:
LOCATION: INSPECT ON:
TYPE OF STRUC RE:
Framing COMMENTSY N N/A COMMENTS
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 3 6 in. or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 lz(w) 16 gauge($) 16D nails each side
Draft st ing 1,000 sq. ft, floor trusses ,�-
An or Bolts 6 ft. or less on center
ce and snow shield 24 inches from walk
Fires ration 1,2,3 hour separation
Fire wall 2, 3,4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min,
Garage Fire Separation.
House side %2 inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceilin Iwall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
L:1SueHemingway\Building.Codes.Inspection.FORMS\Framing Firestopping Inspection Report.doc January 28,2003
) e
Foundation Inspection Report
Office No. (518)761-8256 Date Inspection reqfstc : c dQueensbury Building&Code Enforcement Arrive: a Depart: am/pm
742 Bay Rd., Queensbury,NY 12804 Inspector's InitialNAME:
LOCATION: INSPECT ON: Q
TYPE OF STRUCTURE- ,
-- / Coniments
( Y N N%A
Footings
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection fro freezing
for 48 hours following tMplacement i €/
of the concrete. f
Materials for this purpose on site. ,
Foundation/Wallpour
Reinforcement in Place f 77 .
Foundation Dampproofing
1 Foun ion/Waterpra ing
Type of Dampproofing/Waterproof yk -
Footing Drain Daylight or Sump 4,i1 - k
Footing Drain Stone: r 4
12 inch width '
6 inches above footin
g;
6 mil p ly for wet areasnder slab
Backfill ApprovalT4
Plumbing Under Slab,` '
PVC/Cast/Co of
Copp E
Foundation Insulati-&.jnterior/Exterior
R-
Rough Grade 6`Iinch drop within 10 ft.
L;\Sucliemingway\Building•Codes.Inspection.PORMS\roundation Inspection Report.doc January 28,2003
Foundation Inspection Report
Office No.(518)761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: a D '�!��7 2am/pm
742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials:
PERMIT#:
NAME: LL C,Y-a
LOCATION: Qjl-�V,/-)C2 a L_ INSPECT ON:
TYPE OF STRUCTtTXE:
c-
60mments
Y N/A
FWtings
Piers
Monolithic Slab
Reinforcement in Place
The contractor is responsible fo
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place
Foundation Dampproofing
Foundation/Waterproofing
Type of Dampproofing/Waterproofing
Footing Drain Daylight or Sump.
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil of for wet areas under slab
Backfill-Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
USucHerningway\Building.Codes Inspection,FORMSToundation Inspection Report.doc January 28,2003
0 G
Permit Number
REScheck Compliance Certificate Checked By/Date
New York State Energy Conservation Construction Code
REScheckSoftware Version 3.5 Release lc
Data filename:F:\SHARE\Design\Energy Calc\WAVERLY PLACE\3 Chelsea.cck
TITLE:WP 322 Woodruff
COUNTY:Warren
STATE:New York.{ 2003
HDD:7635
CONSTRUCTION TYPE:Detached 1 or 2 Family r
HEATING TYPE:Non-Electric i'OWN OF OL;,-- 3UF�Y
DATE: 10/23/03 N
DATE OF PLANS: October 22,2003
PROJECT INFORMATION:
3 Chelsea Place
Waverly Place
Queensbury,N.Y:12804
COMPANY INFORMATION:
The Michaels Grop
10 Blacksmith Dr. - �
Malta,NY 12020 e»
NOTES: YV
°/
Standard Woodruff,no options
Silverline 2900 windows
COMPLIANCE:Passes *�w N'� ,
Maximum UA=406
Your Home UA=355 r'
12.6%Better Than Code(UA)
Gross Glazing
Area or Cavity Cont. or Door
Perimeter R-Value R-Value U-Factor UA
Ceiling 1:Raised or Energy Truss 1422 30.0 0.0 46
1st fl walls:Wood Frame, 16"o.c. 1534 19.0 .6.0 78
Ix Mbr(AE): Vinyl Frame,Double Pane with Low-E 40 .0.380 15
Ix Bed#2(AF):Vinyl Frame,Double Pane with Law-E 32 0.380 12
Living#17: Glass 54 0.380 21
Ix Living(D): Vinyl Frame,Double Pane with Low-E 9 0.380 3
lx Dining(AR):Vinyl Frame,Double Pane with Low-E 3.2 0.380 12
lx Brkfst(P): Vinyl Frame,Double Pane with Low-E 17 0.380 6
Foyer#IA: Solid 29 0.350 10
Laundry#20:Solid 19 0.240 5
2nd floor walls:Wood Frame, 16" o.c. 784 19.0 0.0 44
Ix Foyer(AR):Vinyl Frame,Double Pane with Low-E 32 0.380 12
Ix Loft(AID:Vinyl Frame,Double Pane with Low-E I J 0.380 4
Basement Wall I:Solid Concrete or Masonry 1295 0.0 11.0 84
Wall height: 7.6'
Depth below grade: 6.6'
Insulation depth: 6.0'
3x Bsmnt windows:Wood Frame,Double Pane with Low-E . 5 0.520 3
Furnace 1:Forced Hot Air,80 AFUE
COMPLIANCE STATEMENT: The proposed building represented in this document is consistent with the building plans,
specifications,and other calculations submitted with this permit application. The proposed systems have been designed to meet the
New York State Energy Conservation Construction Code requirements. When a Registered Design Professional has stamped and
signed this page,they are attesting that to the best of his/her knowledge,belief,and professional judgment,such plans or
specifications are in comp ance w s Code.
Builder/Designer Date l D Z Z 6 3
" REScheck Inspection Checklist
New York State-Energy Conservation Construction Code,
REScheckSoftware Version 3.5 Release lc
DATE: 10/23/03
TITLE:WP 322 Woodruff
Bldg.
Dept.
Use
Ceilings:
[ ] 1. Ceiling 1:Raised or Energy Truss,R-30.0 cavity insulation
Comments:
Insulation must achieve full height over the plate lines of exterior walls.
Above-Grade Walls:
[ ] 1. 1st fl walls:Wood Frame, 16"o.c.,R-19.0 cavity insulation
Comments:
[ ] 2. 2nd floor walls:Wood Frame, 16"o.c.,R-19.0 cavity insulation
Comments:
Basement Walls:
[ ] 1. Basement Wall 1:Solid Concrete or Masonry,7.6' ht/6.6' bg/6.0' insul,
R-11.0 continuous insulation
Comments:
Exterior insulation must have a rigid,opaque,weather-resistant protective covering that
covers the exposed(above-grade)insulation and extends at least 6 in:below grade.
Windows:
[ ] I. Ix Mbr(AE):Vinyl Frame,Double Pane with Low-E,U-factor:.0.,380
For windows without labeled U-factors,-describe features:
#Panes Frame Type Thermal Break?[ ]Yes [ ]No
Comments:
[ ] 2. lx Bed#2(AF):Vinyl Frame,Double Pane with Low-E,U-factor:0.380
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break?j ]Yes[ ] No
Comments:
[ ] 3. Ix Living(D): Vinyl Frame,Double Pane with Low-E,U-factor: 0.380
For windows without Iabeled U-factors,describe features:
#Panes Frame Type Thermal Break?[ ]Yes[ ]No
Comments:
[ ] 4. Ix Dining(AR): Vinyl Frame,Double Pane with Low-E,U-factor:0.380
For windows without labeled_ U-factors,describe features:
#Panes -"Frame Type Thermal Break?j ] Yes j ] No
Comments:
[ ] 5. Ix Brkfst(P):Vinyl Frame,Double Pane with Low-E,U-factor: 0.380
For windows without labeled U-facto_rs,describe features:
#Panes' Frame Type Thermal.Break?[ ]Yes j ] No
Comments:
[ ] 6. Ix Foyer(AR):Vinyl Frame,Double Pane with Low-E,U-factor: 0.380
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break?j ] Yes j ]No
Comments:
[ ] 7. Ix Loft(AH):Vinyl Frame,Double Pane with Low-E,U-factor: 0.380
For windows without labeled U-factors,describe features:
#Panes Frame Type Thermal Break?[ ]Yes{ ] No
' ( Comments:
8. 3x Bsmnt windows:Wood Frame,Double Pane with Low-E,U-factor:0.520
( For windows without labeled U-factors,describe features:
( #Panes Frame Type Thermal Break?[ ]Yes[ ]No
( Comments:
( Doors:
[ ] ( I. Living#17:Glass,U-factor: 0.380
( Comments:
[ ] ( 2. Foyer#IA:Solid,U-factor: 0.350
( Comments:
[ ] ( 3. Laundry#20:Solid,U-factor: 0.240
( Comments:
( Heating and Cooling Equipment:
[ J ( 1. Furnace 1:Forced Hot Air,80 AFUE or higher
( Make and Model Number
(
( Air Leakage:
[ J ( Joints,penetrations,and all other such openings in the building envelope that are sources of air
( leakage must be sealed.
[ ] ( Recessed lights must be 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly
( with a 0.5" clearance from combustible materials.If non-IC rated,the fixture must be installed with a _
( 3"clearance from insulation.
(
( Vapor Retarder:
[ J ( Required on the warm-in-winter side of all non-vented framed ceilings,walls,and floors.
(
( Materials.Identification:
[ ] ( Materials and equipment must be installed in accordance with the manufacturer's installation instructions.
Materials and equipment must be identified so that compliance can be determined.
[ ] ( Manufacturer manuals for all installed'heating and cooling equipment and service water heating
( equipment must be provided.
[ ] ( Insulation R-values,glazing U-factors,and heating equipment efficiency must be clearly marked on
( the building plans or specifications.
( Duct Insulation:
, J ( Supply ducts in unconditioned attics or outside the building must be insulated to R-11.
Return ducts in unconditioned attics or outside the building must be insulated to R-6.
[ ] ( Supply ducts in unconditioned spaces must be insulated to R-11.
[ ] ( Return ducts in unconditioned spaces (except basements)must be insulated to R-2.
( Insulation is not required on return ducts in basements.
(
( Duct Construction:
[ ] ( All joints,seams,and connections must be securely fastened with welds,gaskets,mastics
( (adhesives),mastic-plus-embedded-fabric,or tapes. Duct tape is not permitted.
( Exception:Continuously welded and locking-type longitudinal joints and seams on ducts
( operating at less than 2 in.w.g.(500 Pa).
[ ] ( Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions.
[ T ( Cooling ducts with exterior insulation must be covered with a vapor retarder.
[ ] ( Air filters are required in the return air system.
[ ] ( The HVAC system must provide a means for balancing air and water systems.
( Temperature Controls:
[ ] ( Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space
( temperature set point of the largest zone.
(
( Electric Systems:
[ ], Separate electric meters.are required for each dwelling unit.
(
Fireplaces:
[ ] ( Fireplaces must be installed with tight fitting non-combustible fireplace doors.
[ ] + Fireplaces must be provided with a source of combustion air,as required by the Fireplace construction
provisions of the Building Code of New York State ,the Residential Code of New York State or
the New York City Building Code ,as applicable.
Service Water Heating:
[ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the
water heater has an integral heat trap or is part of a circulating system.
[ ] Insulate circulating hot water pipes to the levels in Table I.
Circulating Hot Water Systems:
[ ] ( Insulate circulating hot water pipes to the levels in Table 1.
Swimming Pools:
[ ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20%
of the heating energy is from non-depletable sources. Pool pumps require a time clock.
Heating and Cooling Piping Insulation:
[ ] HVAC piping conveying fluids above 105 OF or chilled fluids below 55 OF must be insulated to the
levels in Table 2.
Table]: Minimum Insulation Thickness for Circulating Hot Water Pipes.
Insulation Thickness in Inches by Pipe Sizes
Heated Water Non-Circulating Runouts Circulating Mains and Runouts
Temperature(F) Up to 1" Up to 1.25" 1.5"to 2.0" Over 2"
170-180 0.5 1.0 1.5 2.0
140-160 0.5 0.5 1.0 1.5
100-130 0.5 0.5 0.5 1.0
Table 2: Minimum.Insulation Thickness for HVAC Pipes.
Fluid Temp.. Insulation Thickness in Inches by Pipe Sizes
Piping.System Types Range(F) 2"Runouts 1"and Less 1.25"to 2" 2.5"to 4"
Heating Systems
Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0
Low Temperature 120-200 0.5 1.0 1.0 1.5
Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0
Cooling Systems
Chilled Water,Refrigerant, 40-55 0.5 0.5 0.75 1.0
and Brine Below 40 1.0 1.0 1.5 1.5
NOTES TO FIELD (Building Department Use Only)
1 .
Check Residential Plan Review: One&Two Family Dwellings
Y/N/N/A
}Full sets of plans
Over 1 1,500 sq. ft.—Stamped
Design Loads On Plans: 90 Wind Floor Loads 40 psf
V 70 Ground Snow Load Sleeping Areas and Attics 30 psf
Calculations:
Window Schedule With Glass Size dt
V 'Door.Schedule/Main Entrance 36"Door
Emergency Escape Or Bedrooms and Habitable Space
Above/Below grade,5.7 sq.
Grade,5.0 sq.A.
24"'(h)x 20"(W. )min.
44"Max.Heigh .1
A above floor
tj Residential Check Paperwork Compliance and Inspectors Checklist: OK
Dampproofing/Waterproofing Materials On Plans
/Foundation Drainage On Plans,if required
%"Drop in 10' Exterior Grade
Framing Cross Section For Each Roof Line,Vertical Fire Stopping Every 10'Where
Required
---',Xce and Snow shield 24"Inside Exterior Wall/24"Inside Knee Walls
X Platforms At Exterior Doors
L//Stairway Headroom 6' 8' All Stairs 36"Width
Stair Run and Rise
Winder Run and Rise
1piral Not Allowed From 2ndStory
L./Smoke Detectors Battery Backup and Proper Location
Bathroom Fixtures Proper Clearance
�Iall Width,36"min.
Handrails More Than One Riser On Open Sides
Railing and Guards>30"/Basement Stairs Included Closed Risers More Than 4"in Ht.
C/ Safety Glazing Notes For Required Areas
Garage Fire Separation
Garage Floor Sloped
V /Attic Access
of over 30"—22"x 30"/Crawl Spaces 18"x 24"Access
I/ Carbon Monoxide Detector Lowest Sleeping Level
Soil Test Results,if required
Septic To Well Or Water Line Separation
All Paperwork Signed
>C
Mo
m N \V mz
1*
y
ba 0 rn
y
0 0 �
0
W N
CT co
orw
m � lit Res
$�� $ 124.96,
N 'v
U l
y It
co
rr
v y ? 1
CN
y m R 25,0
69*
p 00' 2 CY
r%