Loading...
2002-391 TOWN OF QUEENSBURY 742 Bay Road,Queensbuq,NY 12804-5902 (518)761-8201 Community Development-Building&Codes (518)761.8256 CE RTOCCUPANrVIFICATE OF Permit Number: P20020391 Date Issued: Monday,January 24,2005 This is to certify that work requested to be done as shown by Permit Number P20020391 has been completed. - Tax Map Number: 523400-309-014-0001-080.000-0000 Location: 110 MAIN St Owner: CUMBERLAND FARMS,INC. Applicant: GLEN STREET SUBWAYS,INC.- This structure may be occupied as a: By Order of Town Board New Commercial Building TOWN OF QUEENSBERY Director of Building&Code AforceK TOWN OF QUEENSBURY 742 Bay Road,Queensbury,-NY 12804-5902 (518)761-8201 Community Development-Building&Codes (518) 161-8256 BUILDING PERMIT Permit Number: P20020391 Application Number: A20020391 Tax Map No: 523400-309-014-0001-080-000-0000 Permission is hereby granted to: GUN STREET SUBWAYS. TNC. For property located at: ] 10 NLAJN St in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: V.S.H. REALTY INC. '7'7'7 DEDHAM St New Commercial Building 150,000.00 Total Value 150,000.00 CANTON,MA. 02021 Contractor or Builder's Name/Address Electrical Inspection Agency 'Plans&Specifications BP 2002-391 Glen Street Subways,Inc. Construction of a 2,000 sq. ft. new building as per plot plan and specifications. $300.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Thursday,September 18,2003 (If a-longer period is required;an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town of Queensbury; Wednesday, September 18,2002 SIGNED BY for the Town of Queensbury. Director of Building Opode forcement Building Permit Application Town of Queensbury-Dept of Corrimunity Development, 742 BayRoad,Q y,NY (518)761-8256 A permit must be obtained before beginning construction' Permit File No. No inspection will be made until applicant has received a Fee Paid valid building permit. All applicants' spaces on this Rec. Fee Paid application must be completed and must appear on the Reviewed By: application form. Applicant: W��w Owner: Address: Address: 7» ,t-0 Z!::- , " Phone#(jr�-/ )5-23 Phone#(Cpee,) Email Address: Email Address: Property Location: Lot Number: t House Number / Subdivision Name: Tax Map Number: V--"New Building: residence /commercial Estimated Market Value of Construction: $ Li Addition: residence/ commercial If an Addition,what will use of new addition be? c3 Alteration: residence/ commercial C3 No change to exterior size: residence com'l L3 Other work(describe Xf E DID Check Occupancyllnformation I"Floor 2nd Floor Other floor 2002 Below sq.ft. sq.ft. sq.ft. Square Feet I -NSBUR TOWN OF OUEF.• I Y Ll Single family dwelling ASP. CODE c3 Two family dwelling Ll Townhouse L1 Multifamily dwelling h�of units U Office U Mercantile U Manufacturing 0 1 car detached garage C3 2 car detached garage Ll 3 car detached garage U I car attached garage 0 2 car attached garage 0 3 car attached garage &r—St4mTwbWWding- commercial , goo& 0 Storage.building- residential C3 Other What is the proposed height of the structure feet inches Will any,second-hand or ungraded lumber be used? If so, for what? lIJO Type of Heating System: electric/. oil wood /forced hot air t baseboard other: Number of Fireplaces to be installed Number of Woodstoves to be installed List below the person(s)responsible for supervision of work as regards to building codes: Name Address Phone Number Builder Plumber Mason Electrician Declaration: please sign below after you have carefully read the statement: To the best of my knowledge the statements contained in this application,together with the plans and specifications submitted,are a true and complete statement of all proposed work to be done on the described premises and that all provisions of the Building Code,the Zoning Ordinance and all other laws pertaining to the proposed work shall be complied with,whether specified or noted,and that such work is authorized by the owner. Further, it is understood that I/we shall submit,prior to a Certific of Occupancy or Certificate of Compliance being issued,as requested by the Zoning Administrator or Dirodor o Building and Codes,an As Built Survey by a licensed surveyor;drawn to scale,showing actual location of all nc�--ns n. Signature- owner,owner's agent,architect,contractor Building Permit Application Town of Queensbury-Dept of Community Development,742 Bay Road,Queensbury,NY (518)761-8256 A permit must be obtained before beginning construction. Permit File No. No inspection will be made until applicant has received a Fee Paid -ea valid building permit. All applicants' spaces on this Rec. Fee Paid $ application must be completed and must appear on the application form. Reviewed By: Applicant: ale)n Owner- \� VcA 1+-4 Address: tto yi-,N 'N,) - 'SN-y-ex!_-A Address: -7-7-7 -7 P (370;� Phone#(��/8 )1929 - 8,:R Phone# (L520)225- 2 -2-_11� j �0 Property Location: Lot Number: House Number Subdivision Name: Tax Map Number:. New Building: residence /c6nunerci- Estimated Market Value'of Construction:$ R:D" IXDO. Addition: residence/�Mom�mercial If an Addition,what will use of new additioni be?* residence C3 No change to exterior size: residence i com'l o Other work(describe Check OccupancyInformation I"Floor 2n Floor Other floor Total Below sq.ft. sq.ft. sq.ft. Square Feet 0 Single family dwelling o Two family dwelling U Townhouse U Multifamily dwelling #of units 13 Office 0 Mercantile 0 Manufacturin K F,-1 1 car detached garage U 2 car detached garage MAY IZ) 2VJ2 0 3 car detached garage U 1 car attached garage TC VVIN U-UUi-_=AM U 2 car attached garage 0 3 car attached garage 13 Storage building- commercial 0 Storage building- residential ----------- Y Other,::g� ,&�,I'J 14002> )�;5 What is the proposed height of the structure /0 feet - 0- ches 4_1_ ?Z Will any second-hand or ungraded lumber be used? If so,for whaT / Type of Heating System: electric/ oil /(g__a)i wood. / orced hot ai V elm rti'd—/other: Number. of Fire to be installed /VO/-)C Number of Woodstoves-to"be installed Listbelow the person(s)responsible for supervision of work as regards to building codes: i - t Name Address Phone Number Builder —71 91A Plumber Mason Electrician Declaration: please sign below after you have carefully read the statement: To the.best of my knowledge the statements contained in this application,together with the plans and specifications submitted,are a true and complete statement of all proposed work to be done on the described premises and that all provisions of the Building Code,the Zoning Ordinance and all,other laws pertaining to the proposed work shall be complied with,whether specified or noted,and that such work is authorized by the owner. Further,it is understood that I/we shall submit prior to a Certificate of Occupancy or Certificate of Compliance being issued,as requested by the Zoning Administrator or Director of Building and Codes,an As Built Survey by a licensed surveyor;drawn to scale,shq.wing actual location of all new co true on. Signature: owner,owner's agent,architect,contractor h.1b - - • /II'�iiii�iii-i-i i--i--ice/ " (acommunityVevelopment Office, 01 Town of Queen « 742•Bay Road- Queensbury, New York■�12804 0 If Date 01 David Hatin,;Director of Building&Codes % Craig Brown,Zoning Administrator•Michael J. Palmer, Fire Marsha/ Stam _.__._- ESTABLISHMENT OF A NEW BUSINESS , CERTIFICATE--OF OCCUPANCY PERMIT APPLICATION! *Note: This application is for occupancy only, with no work requidag a building permit TAX MAP# ; BLDG. PERMIT FILE�pplicable-�'3 � Name of Business: J t��wrt Address -t of Business: 0Mo,cv. - QUESTIONS? CALL 761-8256 OR c�,ct;�. •EMAIL codes0aueensburvnet VISIT OUR WEBSITE FOR MORE Person in Charge or Manager., S 5 F�a d e r� INFORMATION wwiw:aueensbucy.net Business`Phone NumWr (' I G , - Type.of Business ra S4' aOt is G6 S Owner of Property: Phone Numtier(s): -7os - &" `216. Hama cea Owners Address: ,� Sf. Ciao �� .0 /V1 . Oa oa - Provide an acCur-ate:,+a}%oiit of yvur wore,showing ail trvalis, exits;stockrooms, rest rooms, counters and fixture:layout on.a-separate sheet of paper. .signature: Date: Of person submitting this form. Notes I Comments: EMERGENCY CONTACT UPDATE= TO: WARREN COUNTY SHERIFF'S DEPT. F"- 743-2502 RtEASE PRINT DATE: y l 1e2 r BUSINESS NAME: BUSINESS ADDRESS: I4 t� A/�c.;n Sf (' 5� �� tiy % . S-nq BUSINESS PHONE: CS( E-) -7 19-- 7 fa] ;CONTACT 1: F7 . HOME PHONE Wb rI ?b-3 7/4 ADDRESS; 02 ct G i _ . 5 njw a5j2t-ih V C kof CONTACT., 2: v Gee HOME PHON , a 2 -/Z(6 S ADDRESS: Fr✓t rw�� S�;s-t t, (�1 e� 11c , Al -- -- This forrri i �sd to assist emergency Service personnel who:may be called.to your business after-hours;, Please be'sure that the persons,listed on'this-form-will be willing and:available--to respond during.off-hours to assist Police and/or Fire.personnel in. gaining-entry to your building: PLEASE BE.ADVISED THATfAILURE-TO RESPOND TO-ASSIST EMERGENCY SERVICE PERSONNEL MAY RESULT'IN DAMAGE TO-YOUR BUILDING TO FACILITATE ENTRY BY POLICE AND/OR FIRE PERSONNEL. ENERGY CODE COMPLIANCE: APPLICATION TOWN OF QUEENSBURY, WARREN COUNTY 9000 HEATING DEGREE DAYS Compliance Methods: PART 5 - Acceptable Practice Method 1&2 Family Dwellings (only) jeoffa PART 6* - Thermal Rating - Component Trade Offs 1&2 Family Dwellings;. Multi-Family Dwellings (3 stories or less) PART 4* - Design by Component Performance Commercial Buildings-Hi Rise Residential *Requires submission of worksheets P�t r_7 0 APPLICANT'S NAME: PROPERTY LOCATION: MAY Chen aky �-o . qS -�Ao_ ma wjn�, -K\ I-ARC�! r UuEENSSURy r),�'FQ 0 : PART 5 METHOD OF COMPLIANCE. BY ACCEPTABLE PRACTICE: 1 . Gross Floor Area - _'LQ_0D square feet 2 . Type of Heat - Electric Oil Gas Other 3 . Is building mechanically cooled? Yes No 4 . Percentage of area of windows and doors X Over 17% Under 17% 5 . R-VALUES FOR INSULATION GIVEN BELOW MUST CORRESPOND TO R-VALUES AS SHOWN ON PLANS SUBMITTED: Cuxr.Xr_r)ou-\6 Voxn-6 -:s Corlsiruxj,i" +he_ lotk,06 93- a. Roof bUANC\_u--�!3 R b. Exterior walls C. Glazed areas d. Exterior door's R e. Floors over unheated spaces R f. * Edge of slab on grade (heated building) R g. Ba6ement/cellar walls (above grade) R h. Basement/cellar walls (below grade) R 3.. Hedting/coo 1 ing-ducts-piping in unheated space R 6 . Service (domestic) hot water heating device Conforms to. minimum efficiency per code Yes No TEMPERATURE CONTROL MAXIMUM SETTING 1400 - WILL NOT BE EXCEEDED ApplicanVs Sig ature Date Phone Number 1011A, 45� Rcva 70-79R-77-799j- d 365--78.Q_5--Ce I INSPECTOR'S REMARKS: eN .BLDG. PERMIT NO APPLICATION FOR A TEMPORARY CERTIFICATE OF OCCUPANCY A TEMPORARY CERTIFICATE OF OCCUPANCY is hereby requested for the property located at f1 for the following uses: . 1'�'IYp�E? ^ ",-S ZO . DATE SIGNATURE OF APPLICANT TEMPORARY CERTIFICATE OF OCCUPANCY The TEMPORARY CERTIFICATE OF OCCUPANCY is hereby ( APPROVED ( )DISAPPROVED with the following conditions: c- i /,�� E-c�'t-- : TEMPORARY CERTIFICATE OF OCCUPAN DE $10`0.00 received on Date of Issuance Director,of Bldg. & ode nforcement THIS TEMPORARY CERTIFICATE OF OCCUPANCY EXPIRES DAYS FROM THE DATE OF ISSUANCE. NOTE: This Certificate is NOT VALID unless signed.by the Director of Bldg, & Code Enforcement or his designee. Commercial Final Inspection Report Office No.: (518)761-8256 Date Inspection qu t r cei d: Queensbury Building&Code Enforcement Arrive: am/p Depart: _am/pm 742 Bay Road,Queensbury,NY 12804 Inspector's Initi NAME: PERMIT LOCATION: I IC Q DATE: 1-4 — COADMNTS: Y N NA Chimney/"B"Vent/Direct Vent Location Plumbing Vent Through Roof 6"/Roof Complete Exterior Finish Grade Complete 6"in 10' or Equivalent Interior/Exterior Guardrails 42 in.Platform/Decks Interior/Exterior Ballisters 4 in. Spacing Platform/Decks Stair Handrail 34 in.—38 in,/Step Risers 711/Treads 11 Vestibules For Exit doors>3000 sq. ft. All Doors 36 in.WLever Handles/Panic Hardware,if re uired Exits At Grade Or Platform 36(w)x 44"(1)/Canopy or Equiv. Gas Valve Shut-off Exposed&Regulator(18')Above Grade Floor Bathroom Watertight/Other Floors Okay Relief Valve,Heat Trap/Water Temp.110 Degrees Maximum Boiler/Furnace Enclosure I hi% or Fire Extinguishing System Fresh Air Supply for Occupancy/Ventilation Combustion Low Water Shut Off For Boilers Gas Furnace Shut Off Within 30 ft.or Within Line Of Site Oil'Furnace Shut Off at Entrance to Furnace Area Stockroom/Storage/Receiving/Shipping Room(2 hr.), I V2doors >10%> 1000 sq.ft. 1/4 Hour Corridor Doors&Closers Firewalls Fire Separation,2 Hour, 3 Hour Complete/Fire Dampers Fire Doors Ceiling Fire Stopping, 3,000 sq. ft.Wood Frame Attic Access 30"x 20"x 30"(h),Crawl Space Access 18"x 24" Smoke Vents Or Fan,if required Elevator Operation and Signage/Shaft Sealed Handicapped Bathroom Grab Bars/Sinks/Toilets — Handicapped Bath/Parking Lot Signage 3L Public Toilet Room Handicapped Accessible Handicapped Service Counters, 34 in., Checkout 36" Handicap ped Ramp/Handrails Continuous/12 in,Beyond Active Listening System and Si age Assembly Space_ Final Electrical Site Plan/Variance required Final Survey,New Structure/Flood Plain certification,if req. As-built Septic System Layout Required or On File Building Number or Tenant Address on Building or Driveway Water Fountain or Cooler Building Access All Sides by 20' /Driveable Surface 201 wide Okay To Issue Temp. or Permanent C/O Okay To Issue C/C Last printed 6/3/2003 9:27 AML:\PamW\BuiId1ng&Codes\Commercial Final Inspection Report.doc COM31ERCIAL FINAL INSPECTION REPORT ` Building& Code Enforcement Date inspection request received: Office No. (518)761-8256 f Dept. of Community Development �- (-, Town of Queensbury Arrive am/pm Depart 742 Bay Road Inspector's Initial Queeensbury,NY 12804 =LOCATION PERMIT#f 0_ DATE TYPE OF STRUCTURE N/A YES NO COMNfI?'NTS ChimneyP'B"Vent/Dired Vent location C C�Iv 1 �b Plumbing Vent Roof Complete Exteriorfinish grade complete interior/exr/exterior guardrails 42 in.platform/decks h ieeior/exeaior ballastess 4 in.spacing platform/decks Stair handrail 34 in.-38 in. Step risers 7%in. Ruin door 44 in. All others 36 in. Lever handleExits at s Candy to platformade or over req.exit doors Gas valve shut-off exposed&regulator(18 in.)above gra Floor bathroom watertight Other floors okay Hot water relief valve Boiler/furnace enclosure <250,000 BTU N/R 250,000 BTU to 1,000,000 BTU's(I hour) >11000,000 BTU's(2 hour) Gas furnace shut off within 301 or within line of site Oil furnace shut off at entrance to furnace area Stockroom enclosure(1 hour),3/s hour door Storage/receiving/shipping room(2 hour), I '/:doors 1 14 hour doors and closers '4 hour corridor doors and closers Firewalls/fire separation,2 hour,3 hour complete Fire dampers,2 hour fire wall/separation or greater Fire door/shutters 1 '/2 hour,3 hour Ceiling fire stopping 3,000/5,000 sq.ft. Fan shutdown,smoke vents or fan Exit door/panic bars assembly hardware Elevators Elevator signagc Handicapped bathroom grab bars/sinks/toilets Handicapped bath/parking lot signage Handicapped service counters 34 in.,checkout 36 in. Handicapped ramp/handrails continuous/12 in.beyond Active listening system and signage assembly space Final Electrical Site PlanNariance required Final Survey,new structures :As-built septic system layout required ] Okavto issue temp.C/O(Certif of Occupancy) Okay to issue permanent C/O(Ca f.of Occupancy) EDGE of Q� Okay to issue C/C(Certif.of Compliance) \ �� COMMONWEALT9 ELECTRICAL INSPECTION SERVICE, INC. Main Office 357 Elwyn Temce — Manheim, PA 17545 MUNICIPAL CERTIFICATE a ELECTRICAL APPROVAL r i [j`�1Board Cert, . 570 Cut Panel No. .....,,.....oW4R 65 -in Card No, t Owner0.6 1Y 1i to 11 .1 U . .Y1;##§*III#$@'I Ufll{41{li{{li f il4 N 41l411i41fiif1.1..44i 1411.1 H u i 141Y 4i1li!!11 YL44 Occupant !4i 11 {IIIf Y{lfififii444 ilillM44fYO loii Yli411411/i14i411i41ff{lfilf4iliiiiiiililY4Y.iff1144YY+4Y Big 1119614 �L}}} [} 1Y`�y't anonlfi f1f !4!! +..++.fl1! !i4li 3#41i�f!!fli Y+ ff11�61# l4411#904101 $1.4{i i! 11!110i40+0+1 111lii11+1lfilltoll toll flf Installation Consisting of 140 lQ. Y/40# 41# i.R fY /i.�. 114.ii14!N 4111+f� � 111 1 I 1114lfiti!!iflfffFl loll 11iliilii114lllfili++++il+.Rii+l11{{!{lfit;11141•1i1611141114#11461614 s m o/t4f 111R.1++f it Yl4/1i1!!1l44111.1111+1 f 0#144#0101 toil kill 14I111lI evil 116 loll fill 4RiY++li4lRfl tiff 144 iiiit1 Hfi Installed By.. +I 1 . Lie. #66/11f 4 1ff .1+i1f114Yli4646411 The conditions following governed the issuance of this certificate, and any certificate previously issued is cancelled.— This certificate only covers the electrical equipment and installation conditions as of date, Upon the introduction of additional equipment or alterations, application shall be promptly made for inspection. Inspectors of this Company shall have the privilege of along inspection, at a t1 e 1 d if its rules are vi lated, the Company shall have the right to revok is certificate) 4 6 Date .,10 1 a I I#.I 19#0 wool Ito IN iECTORt41444f4141R414.iili!!ll4RiifYili 4141.Yf1.\..1 Y f/61110016 Memhpr NY A.. i.A.F.1. Town of Queensbury Fire Marshal's Office 742 Bay Road Queensbury, NY 12804 Phone (518)761-8205 Fax(518) 745-4437 Fire Marshal's Inspection Report Request SCHEDULE Received: Permit# INSPECTION ON: Name: 5u,(, -,-340 _AM 6)ANYTIME Location: APPROVED N/A Y S NO COMMENTS A EXITS V1 ISLE WIDTHS EXIT SIGNS-NORMAL - BATTERY EMERGENCY LIGHTING FIRE EXTINGUISHERS FIRE ALARM SYSTEM FIRE SPRINKLER SYSTEM FIRE SUPPRESSION SYSTEM �i '� AIL ` HOOD INSTALLATION INTERIOR FINISHER STORAGE COMPRESSED GAS CLEARANCE TO SPRINKLERS CLEARANCE TO HEATING wq?.010A 6 mo,.4-V UNITS CLEARANCE TO ELECTRICAL REQUIRED SIGNAGE EMERGENCY PLAN MAXIMUM OCCUPANCY SIGN -VK CHIMNEY iy) P E)5 , MASONRY ROUGHIN CHIMNEY FINAL A OK FACTORY BUILT ROUGH IN FINAL WOOD STOVE ROUGH IN FINAL VENTED GAS APPLIANCE ROUGH IN FINAL FIREPLACE ROUGH IN MASONRY OK THIS DATE OK I- R"Cd) NOT OK FINAL FIREPLACE FACTORY BUILT ROUGH IN INSPE D BY FINAL 1 V COMDEV/CHRISJIWORD/LETTERS200I/FIREMARSHAUNSPECTIONREPORT11022001 WHITE-BUILDING DEPARTMENT COPY YELLOW-OCCUPANT COPY TIA:L - COMMERCIAL INSPECTION REPORT Request received: Town of Queensbury (518) 761-8256 ARRIVE] az m: .DEPART '; a in Office Use 742 Bay Road Ready at time: Queensbuiy, NY 12804 Inspector's Initi ' Meet: NAME PERMIT# �� 1 At time: f LOCATION 1 s - TYPE OF STRUCTURE INSPECT ON(date): L-21fl-03 Notes: j N/A YE NO '- ChimneyP'B"VentlDirect Vent location Plumbing Vent Roof Complete COMMENTS Exterior finish grade complete r/exterior guardrails 42 in.platform/decks Irk/exterior balusters 4 in.spacing platform/decks Stair handrail 34 in.-38 in. Step risers 7'/4 in. V, Main door 44 in. `�" •��� � All others 36 in. Lever handles 2S-P61C A. ---O\ Exits at grade or platform Canopy to cover req.exit doors Gas valve shut-off exposed&s regulator(18 in.)above grade �>-.VE.#1�, Y--\ Floor bathroom watertight 1�l__ _ Other floors okay c V UafW11 Hot water relief valve Boiler/furnace enclosurep"� (�`-� � <250,000 BTU N/R �l�fT �AC �flL�vG � 250,000 BTU to 1,000,000 BTU's(1 hour) �LCf-1t21>�CE �5 ( [L P lC 6 - >1,000,000 BTU's(2 hour) , ► - L� ,cs�cc�L \ �-��} t Gas furnace shut off within 30 ft. or within line of site {�Qi►i� F Oil furnace shut off at entrance to furnace area VY Stockroom enclosure(I hour),'/4 hour door Storage/receiving/shipping room(2 hour), 1 'I/z doors �� - ,1 >r I %hour_dto_ors and closers ��� -� p 1�� P PQ Jfl %hour oor�;�,4�n,d closers ��"'�"'{'�t�,.. �4vC."1-.t�',y --fit�'E., 'D t>��.- Q- V)C>C`%btA C7 C= Ar`�M�J F + ailslfire sep\aratiol't',21 r;a�-1rcP1 e>osnpl to f�t�� v�c�L LP%TC-vk _ Fire dampers,2-hour fire wall/separation or greater rj SFr�- P-luk -- � J�t 1 K+ Fire door/shutters I %z. hour,3 hour 13P-4m ec\ E Lt t i Fl vz Ceiling fire stopping 3,000/5,000 sq. ft. Fan shutdown,smoke vents or fan Exit door/panic bars assembly hardware V Elevators CDT• BVV--9,-Rl t oG c-0 o Elevator signage Handicapped bathroom grab bars/sinks/toilets — p � -t c p ¢tom -rp LAd _Handicapped ba par lot si a e ©�� Handicapped service counters 34 in.,checkout 36 in. Handicapped raiilli Active listening system and signage assembly space Final Electrical Site Plan/Variance required 1�.5� �["� fit~x'�t� t t�� `�.\'�C) Final Survey,new structures As-built septic system layout required Okay to issue TEMPORARY CIO-Certificate of Occupancy yes no_j Okay to issue PERMANENT CIO-Certificate of Occupancy yes no Okay to issue C/C-Certificate of Compliance yes no Town of Queensbury Fire Marshal's Office 742 Bay Road Queensbury, NY 12804 Phone (518) 761-8205 Fax(518)745-4437 Fire Marshal's Inspection Report Request -39 ) SCHEDULE 1-� Received: Permit# INSPECTION ON: Name: AM PM ANYTIME Location: D APPROVED N/A YES NO COMMENTS EXITS AISLE WIDTHS PA. " LO CAC O�OYM EXIT SIGNS-NORMAL - BATTERY EMERGENCY LIGHTING FIRE EXTINGUISHERS FIRE ALARM SYSTEM FIRE SPRINKLER SYSTEM FIRE SUPPRESSION SYSTEM HOOD INSTALLATION INTERIOR FINISHES STORAGE COMPRESSED GAS FIWA CLEARANCE TO SPRINKLERS CLEARANCE TO HEATING UNITS CLEARANCE TO ELECTRICAL (lb e- Y'ro, REQUIRED SIGNAGE EMERGENCY PLAN MAXIMUM OCCUPANCY SIGN CHIMNEY MASONRY ROUGH IN FINAL CHIMNEY FACTORY BUILT ROUGH IN hm FINAL WOOD STOVE ROUGHIN FINAL VENTED GAS APPLIANCE ROUGH IN FINAL FIREPLACE MASONRY ROUGH IN OK THIS DAT OK OR CO NOT OK FINAL FIREPLACE FACTORY BUILT ROUGH IN _U INSPECTED BY FINAL COMDEV/CHRISJNVORD/LETTERS20011FIREMARSHALINSPECTIONREPORT11022001 WHITE-BUILDING DEPARTMENT COPY YELLOW-OCCUPANT COPY Office Use GENERAL INSPECTION REPORT Inspector: Town of Queensbury Ready at time: Dept. of Community Development Request received: Meet: Building& Code Enforcement At time: 742 Bay Road Queensbury, NY 12804 ARRII - a Notes: (518) 761-8256 Inspector's Initi NAME: PERMIT# LOCA4W INSPECT ON(date): TYPE OF STRUCTURE: k)�ZA RECHECK N/A YES NO COMMENTS Footings/Piers Monolithic Pour Form Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site Foundation/Wallpour Reinforcement in Place Foundation/Dampproofing_ Backfill Approval Plumbing Under Slab Plumbing Vent/Venti in Place Roug>,01umbing_ HeOng Rough-In sulation ter Foundation Walls Interior R- Foundation Walls Exterior R- Floors R- Wal s R- Ceiling R- ?2D Duct work or piping in. unheated spaces (f �- _ �— Proper Vent,Attic Vent Framing Jack Studs/Headers Bracing/Bridgmig— Joist Hangers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1,2,3,hour Penetration Sealed Fire Wall 2,3,4 hour Firestopping L:\Suel-lemingway\Building.Codes.Inspection.FORMS\GENERAI.,INSPECTION REPORT.doc Use INSPECTION PCORT � Inspector: Town of Queensbury Ready at time::" Dept. of Community Development Request received. f 'I 6 Meet: Building chi Code Enforcement At time:. �� 742 Bay Road Queensbury,-AT 12804 ARRIVE a /per AR 1 D C> p Notes: (518) 761-82M Inspector's In' NAME: PERMIT 4��M2 LOCATION: n Aw,: Lyj INSPECT ON(date): TYPE OF STRUCTURE: RECHECK _ N/A YES NO COMMENTS Footings/Piers Monolithic Pour Form Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site F'oundation/W allpour Reinforcement in Place r I;oundation/D ampproofing Backfill Approval Plumbing Under Slab Plumbing Vent/Vents in Place Rough Plumbing ng Rough-In aS' _ oundation Walls Interior R� Foundation Walls Exterior R- Floors R- Walls R- Ceiling R Duct work or piping in unheated spaces R- Proper Vent,Attic Vent w Framing _ { Jack Studs/Headers Bracing/Bridging Joist Hangers Jack Posis/Main Beam Air Infiltration Barrier Fire Separation 1;2,3,hour Penetration Sealed Fire Wall 2,3;4 hour_ Firestopping V3 Z L:\SueHemiugway\Building.Codes.Inspection.FORMS\GENERAI.INSPECTION REPORT.doe W200 W-1-0 Office Use .GENERAL SPECTION REPORT Inspector: Town of Queensbury Ready at time:­ Dept. of Community Development Request received: Meet, Building& Code Enforcement At time: 742 Bay Road Queensbury, NY 12804 ARRIVE a Notes: (518) 761-8256 Inspector's Iniu* NAME: vaq PERMIT# LOCATION; C( o INSPECT ON(date): TYPE OF STRUCTURE: RECHECK N/A YES NO COMMENTS Footings/Piers Monolithic Pour Form. Reinforcement in Place The contractor is responsible for providing protection fiom freezing for 48 hours following the placement of the concrete. Materials for this purpose on site Foundation[Wallpour Reinforcement in Plake Foundation/Dampproofing_ Backfill Approval Plumbing Under Slab Vurnbing Vent/Vents in Place C> ough Plumbing__ Heating Rough-In —C>\ kA, Insulation Foundation Walls Interior R- Foundation Walls Exterior R- Floors R- Walls R- Ceiling R- Duct work or piping in . unheated spaces R- Proper Vent,Attic Vent "Framing eaders r acin 'idging T angers Jack Posts/Main Beam. Air Infiltration Barrier ck) Fire Separation 1,2,3,hour Pi-n tr ti0n S ale d reTa112 3,4 h o ur �`� � L'�J' � Firestoppin —\7t> L:\SueHemiligway\Building,Codes.Inspection.FORMS\GENE-RAL INSPECTION ORT.doc Office Use GENERAL INSPECTION REPORT Inspector: Town of Queensbury Ready at time: Dept. of Community Development Request received: Meet: Building& Code Enforcement At time: 742 Bay Road Queensbury, NY 12804 ARRIVE L a In: E �qm Notes: (518) 761-8256 Inspector's Initi NAME: Bf a-n::;l PERMIT# 2-9�� LOCATION: 5jQq4* INSPECT ON(date): V TYPE OF STRUCTURE: RECHECK 0C N/A YE VI NO COMMENTS �Ootings/Piers Monolithic Pour Form V - k Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site Foundation/Wallpour Reinforcement in Place Foundation/Dampproofin Backfill Approval Plumbing Under Slab Plumbing Vent/Vents in Place Rough Plumbing-_ Heating Rough-In Insulation Foundation Walls Interior R- Foundation Walls Exterior R- Floors R- Walls R- Ceiling R- Duct work or piping in unheated spaces R- Proper Vent,Attic Vent Framing Jack Studs/Headers Bracing/Bridging Joist Hangers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1,2,3,hour Penetration Sealed Fire Wall 2,3,4 hour Firestoppig- L:\SueHemingway\Building.Codes.hispection.FORMS\GENERAT,INSPECTION REPORT.doc t � 11 Q 4- 4- 4. �r Q N „ w u a v .w Oc La c -c 4W �- .. \�cil- C � a �MOVN co o Y) Yr 0 � of- � �4� v v M 44 M N AA�''I 4j v oO 0. � `mod; 'v W1 0 I S. , 4J Ulr- 0 a U A. 0 �w , { a ro ijO NC a 0On ad �� � � , . aPC ro ro E ° ro x 0 Or+ . T3W °,� -� r a , n � N 0 P a 5 �1 'r � W �Al in 1 0 P Z 0 4 .r- Q. S. Ap ~ i" r c �. v w s (f v N U C v ° ,X r-+ 00 4- ro v)�l /� WIL v W T '"' r 14" "�"� N �~ or. U}Y/ it C C C (U 0 o au. C4-W � �. 0 40 rrr � u, y) � pCI I� � � +� v I m " d i C N it � (� �N r» 0 Z `D W v S N J � roW0MOIJ N �H ' O 0).� 4C� >» Cro' � ,� � r~ W IOU a1. V) U 4j N (n4-10CaNLuN0aL -0Cv) vU � � p.cU., a � C} ro r� C Gl �r Nr a>� v - Wr � w ro ,r. p.QpQvQGUS ,rr CIO 0 Ix � JQ � U1N � �. m� na. 1.LU- (4 �' w Office Use GENERAL INSPECTION REPORT Inspector: t4t,P mV Town of Queensbury Rea a Dept. of Community Development Request received:2 Meet: Building& Code Enforcement At time: 742 Bay Road Queensbury, NY 12804 ARRIVE-am/pm: DEPART dam/pm Notes: (518) 761-8256 Inspector's Initials NAME: Wqj PERMIT# 2,- 111 vkat, LOCATION: INSPECT ON(date): 1016 TYPE OF STRUCTURE: RECHECK N/A YES NO COMMENTS Footings,Tiers Monolithic Pour Form Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site Foundation/Wallpour Reinforcement in Place FoundationfDampproofing_ ackfill Approval Plumbing Under Slab Plumbing Vent/Vents in Place Rough Plumbing_ Heating Rough-In Insulation Foundation Walls Interior R- Foundation Walls Exterior R- Floors R- Walls R- Ceiling R- Duct work or piping in unheated spaces R- Proper Vent,Attic Vent Framing Jack Studs/Headers Bracing/Bridging Joist Hangers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1,2,3,hour Penetration Sealed Fire Wall 2,3,4 hour Firestoppin L:\SueHemingway\Building.Codes.Inspection.FORMS\GENERAL INSPECTION REPORT.doc Office Use GENERAL INSPECTION REPORT Inspector: Town of Queensbury Ready at time: Dept. of Community Development Request received. Meet: Building& Code Enforcement At time: 742 Bay Road Queensbury, NY 12804 ARRIVE am/pm; DEPART �} - am/pm Notes: (518) 761-8256 Inspector's Initials NAME: "V�6 PERMIT# 67 LOCATION: N'--pytd e INSPECT ON(date): 10110 f� TYPE OF STRUCTURE: RECHECK N/A YES NO COMMENTS Footings/Piers Monolithic Pour Form Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site Foundation/Wallpour Reinforcement in Place Foundation/Dampproofmg Backfill Approval Plumbing Under Slab Plumbing Vent/Vents in Place Fati �hPlumbingng Rough-Ination F�oizndation Walls Interior R- oundation Walls Exterior R- 1 Floors R- WaI1s R Ceiling R- Duct work or piping in unheated spaces R! Proper Vent,Attic Vent Framing Jack Studs/Headers BracingBridging Joist Hangers _ Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1,2,3,hour Penetration Sealed Fire Wall 2,3,4 hour +1 Firestopping L:\SueHemingway\Buiiding.Codes.Inspection.FORMS\GENERAL INSPECUON REPORT.doc Office Use GENERAL INSPECTION REPORT Inspector: Town of Queensbury Ready at time: Dept. of Community Development Request received: 7 Meet: Building& Code Enforcement At time: 742 Bay Road Queensbury, NY 12804 ARRIVE2,�*�a** m- P T7,-�M amlpm Notes: (518) 761-8256 Inspector's Ini als - & I I NAME: PERMIT# 2002--3 q I LOCATION: INSPECT ON(date): TYPE OF STRUCTURE: RECHECK N/A YES NO COMMENTS Footings/Piers Monolithic Pour Form Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site *oundation/Wallpour Reinforcement in Place (LED w)i Foundation/Dampproofm Backfill Approval GL Plumbing Under Slab Plumbing Vent/Vents in Place Rough Plumbing_- VtA Heating Rough-In Insulation Foundation Walls Interior R- Foundation Walls Exterior R- Floors R- Walls R- Ceiling R- Duct work or piping in unheated spaces R- Proper Vent,Attic Vent Framing Jack Studs/Headers Bracing/Bridging_ Joist Hangers Jack Posts/Main Bearn Air Infiltration Barrier Fire Separation 1,2,3,hour Penetration Sealed Fire Wall 2,3,4 hour Firestoppmi L:tSucHemiiigway\Building.Codes.Inspection.FORMS\GENERAL INSPECTION REPORT.doc Office Use GENERAL INSPECTION REPORT Inspector: Town of Queensbury Ready at time: Dept. of Community Development Request received. Meet: Building& Code Enforcement At time: Jg 742 Bay Road Queensbury, NY 12804 ARRIVE ; a Z DEP RT otes: (518) 761-8256 Inspector's Initi s NAME: PERMIT# LOCATION: INSPECT ON(date): TYPE OF STRUCTURE: RECHECK N/A YE i NO COMMENTS oting-tonolitsh Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site Foundation/Wallpour Reinforcement in Place Foundation/Dampproo frog _ Backfill,Approval Plumbing Under Slab Plumbing Vent/Vents in Place Rough Plumbing_ Heating Rough-In Insulation Foundation Walls Interior R- Foundation Walls Exterior R- Floors R- Walls R- Ceiling R- Duct work or piping in unheated spaces R- Proper Vent,Attic Vent Framing_ Jack Studs/Headers Bracing/Bridging Joist Hangers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1,2,3,hour Penetration Sealed Fire Wall 2,3,4 hour Firestoppmi L:\SueHemingway\Buildin&Codes.Inspection.FORMS\GENERAL INSPECTION REPORT.doc STATE OF NEW YORK 2,&02-- 391 DEPARTMENT OF HEALTH Glens Falls District Office 77 Mohican Street, Glens Falls NY 12801 (518)793-3893 Fax(518)793-0427 Antonia C. Novello, M.D., M.P.N.,Dr.P.H. Dennis P.Whalen Commissioner Executive Deputy Commissioner September 25, 2002 Kevin F. Brough; 870 State Route 9 Queensbury,NY, 12804 - Re: Proposed Subway (T) Queensbury, Warren County Facility Code# 56-AC46 Dear Mr. Brough, f I have reviewed and approved the plan submitted for the above proposed food service establishment. Please contact this office when the facility is ready for a pre-operation inspection. Sincerely, i Joseph Curatolo Principal Sanitarian Cc: Anita'Gabalski, District Director . Michael Sh u at senior Sanitarian Cade enforcement O{rice, (T)Queenst FINAL, -- C MMERCLAL INSPECTION PORT Request received. 2 2 Office Use Town of Queensbury (518) 761-8256 ARRIlrE� pm: DEPART am/ rn 742.Bay Road (.) Ready at time: Queensbury,NY 12804 Inspector's Initials_ NAME CLJP'aeP1akol Form j � PERMIT# ��a2 - 3q l' At time: LOCATION f?1 TYPE OF STRUCTURE INSPECT ON(date): .2 Z Notes: 3' �5 , Chimne /"B"Vent/Direct Vent location N/AYES NO Uq 7 Plumbing Vent Roof Complete COMMENTS Exterior finish grade complete Interior/exterior guardrails 42 in.platform/decks 0 60ACYAP- c urb a a 1d Interior/exterior balusters 4 in.spacing platformtdecks i J c� t° Stair handrail 34 in.-38 in. AY155��cnvPSS o`� 415t .e of isla, � umw Step risers 7%in. �a�« �� and fVA Sa Main door 44 in. All Others 36 in. �1`fta�F�`pnu� 51gqpS� �1� cox �1OU TI)OA E'A Lever handles `C4uj,DOS J sP tc� 5i�,�yea, N 5 f e no-Fin. Exits at grade or platform �j rrc�dUS i f�QVltc a 11 iUin I`tt �`QSS 4- Gas to cover req.exit doors 8 Gas valve shut-off exposed&:regulator(18 in.)above grade P_5i'-bS_ M- JS51n 9 a ttd C 106 9J of OW5 m f55t�iv Floor bathroom watertight ,� Other floors okay y �e:�wt?�� c"�,.ttol a�.r� ��Y�2a Hot water relief valve I Boiler/furnace enclosure �+ t / #Z) c250,000 BTij N1R Id we izo fl d�flaiwA Ctrs fer coal Y 250,000 BTU to 1,000,000 BTU's(1 hour) j�11 U g >1,000,000 BTU's(2 hour) cue)M5 - ° '� 52��241 yG��^oSt' ded) Gas furnace shut off within 30 ft.or within line of site 1 Oil furnace shut off at entrance to furnace area Stockroom enclosure(I hour),%hour door Storage/receiving/shipping room(2 hour), 1 'Iz doors . 1 'Y2 hour doors and closers %hour corridor doors and closers Firewalls/fire separation,2 hour,3-hour complete f Fire dampers,2-hour fire wail/separation or greater Fire door/shutters 1 'Y2 hour,3 hour Ceiling fire stopping 3,000/5,000 sq.ft. Fan shutdown,smoke vents or fan Exit door/panic bars assembly hardware Elevators Elevator signage Handicapped bathroom grab bars/sinks/toilets Handicapped bath/parking lot signage Handicapped service counters 34 in.,checkout 36 in. Handicapped ramp/handrails continuous/12 in.beyond Active listening system and signage assembly space oe Final Electrical ly ` ��, �i mite Plan/Variance required a rtetl " Final Survey,new structures Q u �v �v� n0 So ,,, As-built septic system layout required ( } 0J '�(�.�'(02 o Okay to issue TEMPORARY C/O-Certificate of Occupancy yes n 41 Okay to issue PERMANENT C/O-Certificate of Occupancy yes no 46 Okay to issue C/C-Certificate of Compliance yes no j:z- . e Use GENERAL INSPECTION REPORT Inspector: Town of Queensbury Ready at time: Dept. of Community Development Request received.- Meet: Building& Code Enforcement At time: 742 Bay Road Queensbury, NY 12804 ARRIVE a R otes: DE5 _2;L,T am 4��M (518) 761-8256 Inspector's Init;, � L NAME: L-,-) PERMIT# GqQ 2--3 9 Y,- LOCATION: V V V X4,: INSPECT ON(date): M TYPE OF STRUCTURE: RECHECK N/A YES, NO COMMENTS Footin ie it is i Pour Forni Reinforcement in Place V1— The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site ic Pour Foundation/Wallpour Aeinforcernent in Place Foundation/Dampproofing_ Backfill Approval Plumbing Under Slab ....... Plumbing Vent/Vents in Place Rough Plumbing_ Heating Rough-In Insulation Foundation Walls Interior R- Foundation Walls Exterior R- Floors R- Walls R- Ceiling R- Duct work or piping in unheated spaces R- Proper Vent,Attic Vent Framing Jack Studs/Headers Bracing/Bridging. Joist Hangers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1,2, 3,hour Penetration Sealed Fire Wall 2,3,4 hour Firestopping L:\SueHemingway\Building.Codes.Inspection.F,ORrvfS\GENERAT,INSPECTION REPORT.doc 1 v �- vvvz a +) vvv M w I� U a v 4J w � � �, 4 w 4 v 0 T i I- '�- o� M 1 U) 4J r v >1 �4 C► ' N ' v h- C v4ro��roNQ1�J'rb`tlYrCvvr1»' �tG �� 1p ,r r * 0 U i 1 +,, v ,ra I +J-C is ,JW E 0U vxpw 0 � C � 0 ro v A S. 0 E m z o N V)0.W CO C I C (DEW-C U � 0)4M � Mv) +) vW wcr U � 41M UV?I 1 v �-. �r- V)oCCCroC� cvo . © W 0 " V? N Q x 0 0 0 0 t S. e w CQ u C r- M 04. 4r. 0 0 0 -F- -r'r- !I1 LL LV) I-q 0 0 O.w � 0 4~W }J 0 M 0 -P 4J 4 v I �". r ' v m 'N rro .000 I z � ^ CMb,(om Mw a) W :3 W 0 M+) a)L Q) c H �'c Ic c c It'4.Ic S. E NJ ol� vj F U 41 M N4-Q. illCO. NWNOLOCVIQ)U:3 :5QCU ,r. O 'o � z ..! o 0 rl'� (v 'rW ro .r. 0L000 $ 0GUSgr- o � �• � TOWN OF QUEENSBURY 742 Bay Road, Queensbury, NY 12804-5902 518-761-8201 May 16,2002 Kevin Br6 e Main Street Queensbury3 NY 12804 Dear Kevin: The following is a Est of items whit own on the plans in order for this Department to issue a buildi L e need structural drawings e of construction for this building,with all design loads and details. This should include the basement drawing as well. The plans must be stamped. 2. ere needs to be a second exit directly from the public space, as two exits are required because the occupant load is over 50 people. i-A e need a detail on the structural drawing showing the run and rise of the stairs. The run and rise must be seven inch rise,eleven inch tread. /The-interior stairwell of the basement must have a one hour rating,which requires 3/4hour fire doors at top and bottom of the stairs. !oJX,,_ !� e need'a complete fire protection plan showing smoke detectors, heat detectors,pull stations, horn strobes,as required-throughout the building. Along with this,any HVAC units must shut down upon activation of the fire alarm system. Also,signage will be required if this alarm system is not monitored by central station,stating that this is a local alarm only and occupants are to dial 911. There needs to be a note on the plans that says that all plumbing will be cast iron or copper. .,o0000Description of the type of heating and cooling system that will be provided for this building. Exit light and emergency light layout for this building. D rtification from the architect stating that the building is in compliance with Part Four of the Energy Code. counter at the cash register must be at a maximum height of 34 inches for handicapped accessibility. (qjd�hancap bathrooms do not meet the dimensional requirements for handicap bathrooms. The w he the fixtures are placed must be seven foot six inches wide, and the depth of the bathroom must be six foot,seven inches in depth. If you need details for this,please contact me for the proper standards. A14 15 "HOME OF NATURAL BEAUTY. . .A GOOD PLACE TO LIVE" SETTLED 1763 Based on a review of the plans submitted, this appears to be all the,items that need to be addressed. Once all tliese items have been submitted and reviewed by this office for acceptance,a building permit will be issued. If you have any questions,please don't hesitate to contact me. Sincerely, TOWN OF QUEENSBURY David Hatin,Director Building and Code Enforcement DH/mg GENERAL' BUILDING CONSTRUCTION CHECKLIST Subchapter E Applications Owner: 5L)'64N-7 Reviewed by: Location: me',, E4 Date:' Type of Work: Pet-, Within Fire Limits: Date of Substantial Completion: Note: To.pies listed in italics__are.._available. only to buildings which are 10 years or older. Is this a Minor Building_? See Table 'l-1233 Yes or No No Topic Code Required or Actual Section Allowed 1 Occupancy proposed 701.4 Fire Hazard Class 702 2 Construction Type 704.1 3 Height & Fire Area 705.4 Basic Area Tables 705 Basic Height Accessibility 705.5b goo( Sprinkler Increase 705.5c 109 allowance 1233.2c 3 Story -wood frame 1233.2d 4 Space I Requirements Ceiling Height 762.3 762.4 Existing Calling 1233.3b 5 Light & Ventilation 763 Artificial Light 763.1 Natural.Light 763.2 Ventilation 763.3 Existing 1233.3c '6 Special Stairs 764.1 r C-1 No _ Topic Code Required or Actual Section Allowed 7a Exits J Number 765.8 jVW o. 4`�f One Exit Permitted Tb X-765 -Units of Exit Width Distance of Travel Tb VI'-765 Dead End Corridor 765.lj Enclosure Tb III-704 Existing Enclosure . 1233'.4c Corridor Width Tb *I-76S"' Door Width Tb V-765 Existing Doors 1233.4b Smoke Stops 765.2a Opening Protectives Tb III-771 Panic Hardware ' 765.5a4 Door Alarms 1060.9a 7b Stairways 765.4 Access to.Roo£ 765.4a . Dimensions Tb IV-765 Existing Dimensions- 1233.4a4 Combustible stairs 765.462 765.4c3 Existing Comb. Stair 1233.4a2 Minor Bldg 1233.4a6&7 Handrails 765.4all 8. Safety Glazing 766.1 9. Garages .and-Parking 767 Structures 10 Malls. and Passageways Passageways 768.1 Malls 768.2 11 ; Atriums 769 Existing 1233.8 12 , Exterior Fire Spread Part 770 Distance Separation Tb-I-770 Existing 1233.5b Tb IV-1233 Construction Limits- 770.2c&d Type 4b & 5 1233.5c Party Walls 770.6 Parapet 1233.5a Finishes 770.8 C-2 No Topic Code Required or Actual Section Allowed 13 Interior Fire Spread Part 771 Fire Separation Th 11-771 , Mixed Occupancy 771.4a6 Allowable Mix 1233.6b Openings 771.41 Existing Openings 123'3.6a Fire Stopping 771.5c 14 Interior Finish -772.2 Existing 1233.7 15 Plastic Materials Part 773 Part 1120 Existing 1237.3 16 Fire Protection Equip Fire Alarm System 774.2 Zoned System lb60.2a5 Battery Backup 1060.2dl Pull Box travel Th 1-1060 Fire Dept Connection 774.1b Detection system 774.3 Sprinkler System 774.4 Standpipe System 774.5 Yard- Hydrants 774.6 Watchman System 774.7 Auto Vent Alarm 774.8 Cqodinated Fire Safety 774.9 17 SPECIAL HAZARDS Areas of Pub. Assemb. Fire & Smoke Det. 791 Sprinkler System 792 Gas Pumps I 774.10 1231.3e Emergency Ventilation 1004.2f Fan Shutdown 1004.2e Exhaust Hood System 1064.2b 18 -Design Loads Snow 803.3 Floor Th 111-803 Wind Th V-803 Th VI-803 Existing Adequate 1 1237.2 F c-3 No Topic Code Required or Actual Section Allowed 19 Plumbing Fixtures 900.2 Materials 904.6. .Freezing 850.7 Existing Adequate 1237.1 20 Heat Producing Equip. Prohibited Locations 1000.2d Enclosure .771-4j Air Supply 1000.2g Vents and Chimneys Prohibited Uses 1005.2 Outlet Location Th 1-1005 'Ex.isting Adequate 1237.1 21 'Electrical Metal Veneers 1030.lg Emergency Power 1032.2 Emergency Lights Th 1-1032 Exit Lights 1033 Existing Adequate 1237.1 22 Accessibility A117.1-92 Extdrior Facilities 1101.1 Interior Routes 1101.3 Interior Elements 1101.4 Areas of Refuge 1101.5c Assembly Space 1101.6 Specific Occupancies 1102 Existing Buildings Part: 1236 23 Energy Requirements Energy Code Certification 7810.10 '�, l�,j�lLv,� ,�L ae�' /,d�- J'h f v(� r/j.//rChlta•.a/ /��. - C-4 02/28/03 FRI 11:56 FAX 5742692426 Company Fax 121 002 E " PES' ASSOCIATES, INC. Engineer's•Surveyors•Construction Land Planning 105 Enterprise.Drive Office:(219) 269-5988 Warsaw, IN 46580 Fax:(219) 269-2426 February 28,2003 ME Doug Childrose Cumberland Farms 777 Dedham.Street. ' Canton,Ma 02021 , RE: Superior Canopy Job B-42-009 Queensbury,NY Dear Mr. Childrose: This is-to certify that the Queensbury Subway building was built according-to the design drawings for this project. If you have any question please contact us. Jarl �p�E OF^F r, .... N. TO emeter,P.E.,S.E. w ' Ra�'fSS10Na�' 02/2NO3 FRI 11:56 FAX 5742692426 Company Fax IM001 PES ASSOCIATES., INC. Consulting Engineers e Surveyors a Project Managers 105 Enterprise Drive Office: (574) 269-5988 Warsaw, IN 46580 Fax: (574) 269-2426 E—mail: pes0keonline Date: Fax Memo is From: 10(Actyl-e— Fax Memo is To: r i z, Re: -S er(dv- Memo: MY , Y%F_' z4 2.4 t t doe L Signed: This FAX contains a Total of e� pages including this page. Please notiry us at the number above if you did not receive all orthe pages. OCT 02 2002 13:13 FR CFI—PLANNING DEPT —781 830 4090 TO 915187454437 P.02/03 GENEFAL NOTES: m 5TATE AMLWA M b IMLL RE WARA1FCAS. ES NOSE: ALL SItSi SIIAT> BC ATE 092,70 MIJO s INIS STEEL t5 IN Si tuaNG 4r;K S+uLL ADDITION TO NORMAL G'DMt YL ON pmA-90,wx I FOUNDATION WAIL AND FOOTING STEEL 3,ALL 1 c om w4gss NOlmo mHr rtSL stuul RE Ft�mtwm IN Tme jw PIM 10 tROrItiNT.Ir! T .ALL I= SIWPiGTIWd E»4T�RAOCS 1TEIOERS Allo 10 T1TG { NATDHi1L 11AICFTEB Olt YLK (6)i�5 NERiti RER�R WRIT 11 WAIL'RIDArORCINC NOT / ►pETUL4 TIES AS NEEDED FOR SNOWN FOR =90015 p P1Mt fps ARE tlE C(1N6TRUCRON ONLY. FIDDTER NDTM' 1 314'� 1.Taps OF ALL M=MUST ROOM TFE WME"A'" UKE4 cBIRR a 0 0• 1-2' }' 9,mmm FOUICITm ,of CMA=M-'W.SH4L STUAYALL HAYS A IME-4 [ONPN M SMUVN IV MOD PST AT B • am. T .S/r JI . uL�To RdMWEE <O Inmd"BE,AM Bets �aat bD,AND A.A.WL KOM rRsWRE Or 2=5 P'F AN'4.PASIX 3M. T.S.COLUMN PR,S=op IM P5pM WK UM AssaNm FW a=NW- ns/6 N b'-8 YnTM THE Fvjn,*&F srt[earmmWs UOCATE mmoami (2) 5/B14I--024,SL W sm COF M R SI14L f ro NtaT tz rETa E DINI riN A FM Fv�l 9MW#fOWM TOR 0�R M • 14' 6' r1/2'"-FLOOR ERTLTIDN NOTES a e �5` Ir +T DE KPAN T,xL i>mm os mun eE ww"W N a TRFN'Sr1 M-w"(I I(F dows NCoL ` W16926 S5 3/4' FLOOR BEAM Z,ALL Mu IE:=NA w4%No 1£REDO CAG y 1' B TRECtEO KW WE FUL AN Jp7ER IT NAS A All AMU A125 BOLTS SHALL M iNSTk=PER UZ TIES AS NEEDED FOR Ir STUD Vw MM SFWWATtON FOR SSSTpCNM us1w AM OR AMWJ5, CONSTRUCTION ONLY WELD PLATE 'F V-7' 60DE:1>�NYSTAMpi ONANb _ PlUII D9i I GOOF-miz9 VQL 9 i6¢DWEl5.4 )2'O.C. (TYP.) ROOF SNOW LOAD: 64 P5FROOF LIVE LOAD: - 20 ASF ROOF DEAD Loan: — PsF WIND SPEED & EXPOSURE: 75 MP),. NA LATERAL WIND LOAD: 1s PSF UPLWr WIND LOAD: ' PSF sm=zm ar • A 14%fRATtON GDEr3tpENIS TaNJ•DMR 2g" NOTE: OPTION TO WET SET a" ` 6 it (3) #4 REBAR CONTINUOUS `� DOWELS IN CONCRETE AS a`" � ! NEEDED, SECTIONAT PILAR�TJ� f�TEAR_ (Typ) NOT TO SCAL Er ,t� OF NEW ASSOCIATES.INC. g*StP pI. D'I: rD'9.f soeDir'eiro�.tAr ,raurAletau smam1a1 >bctr•aoa+ltr n SUPERIOR CANOPY CORFMTIONi � ,� �,�'' 3NIaN.GY�AwMbMM�1laaMan.NAi1'/1I�+a�,,, �Qp "� 5 �,,'� ctAl�waeLs.uaaFARtAe I P�" to—Vo w SUDWAYQUEENNKURYOUiDM tTIJEeNEptTRr.W QEVA710M scuR7Au4S ' TAr.,rruNa L3Oi�Qd13 �TO1N>rif I'i7l�¢ 1 DFE nnT R;)'7 AP 12:30 5742692426 PAW.02 UU I Ud GI Ue 1Ji lJ rK k-r i—rLHNIN i INU Utr 1 —(0l tSJLJ 4UVU 1 U 71J1tY(4J44J f t'.t3J/YJJ aEN m Nam. �. 1.w.cmwm s WOAK W"JK e IN A uwa to FQWW ALL STARE M:oO4.:M Ave"61AA'W' z Au.AtItU¢IAF:AI.SiTa EIWL III;ASiN AM ft mmou NOTE: SHAPES,11AM,LYC..10,W gTxLCnom tLWC AMID+mml THIS STEEL IS IN mupLY VW MIA A-15M I21ADC 6 ADDITION TO NORtdAL kon VNNDATION WALL s Au.ttEI p WaLSs OVE attr WSE.StW2 ALL FGAFDNiIfD AND FOOTING STEEL. N ttl6 SW W tg pg o SMPU Hy ff FILP U ALL 1 ' WOm Misr B�ICNFa1DAD er CLRitFtW>�AAfD m tfg IIMFCAMONS E7W tAier AM LN1OtIK Dlmanp ON inE DAwPN�",ro mAiS, WALL RE114FORCNG NOT 4.�MXIM y ,CAM AND SPW-S AM M BE (6)JS>ETIrAL'RE�WITH SHOWN FOR CIARIT7 wo PUMA FOR cONSTRtsC m ONLY, I FODTfR NDTES: 1.Ws or AL romm f4u5T UN1t."SS VNIR L'N?i7CO3 AiiAdNl AN[3M#O� C0900t FCU*UrAK BYE WC4N 3,om pm M%1r AS'B STEWWALL KK A tout Au M K G 44 TWWAI.As,W Aetis cwne EL ANo A.A_nL BWM iRMqj Or y.WO KF AND A M74 5mL Ffrr. M OF 2C0 FSFfFT KAvE Ka A3SWED FUR OEM" i.5.CI}Lt1NN THE Fl"IM IF slit:DDNOIIICI�MW-RE CWTAWAAS Q 3"y5/8 ir0'-8'tVftN 5m.mi mxs,ski.me=Via K FEA "Ep"TN A t2) �/a o-s tANC GWY aF rHE&Z JOW FMWWM m 7K BETA t7+CAm WELDED STU05 iFt FIADt OL9�i A tlF FOUNaAONs ttaoR to cDnaiRucr Lar t4" o a S 5Ug-L007 ERCTON NOW. 3/4"PLYWOOD t�mm BE v4AtFitIl um A 1t"Lm P� D PAN 1 W12mis 12 I/8• 2.ALL MU M s VJA MS)LT tA»�kIE�CLa�ELr FLO R 2W TU VWy -a AND 15 Pu�fiiAt.ADAYSit LEVIL MIR 11 MS MN 1, S.AIL AMM A=NjS qL&L it WMALL0 M THE t2"STUD 2000 1L9G9 l2 tPAIQI/GIF 51>o�IttML NliNis um A aN MW PKI& 7E6 A5 NEEPEO FOR - CONSTRUCTION OPT.Y WELD PLATE 5/8• 7 unttooaKFrotFA is 9-t0 1ttOL uY.n'IA1E IRRW PREVEaii1L7NANt} CaOE: euNDSN3cWtTTTLE®VIOLB ROdF SNOW LOAD: psr p9F Roor LME LOAD: 29 #6 OOWELS 6 12'D.G. MR) - - ROOF DEAD LOAD-- - 20 PsF WIND SPUD ; EXPOSURE: Psi'+ LATERAL WIND LOAD- I- psF UPLIFT WIND LOAD: R_ _ sr1zLl�Sala v NA ACcisYAlAtgM Cq(CAtCLNf6r ND19i OPYION TO WET SET (4) /4 IMM CONTINUOUS DOWr1S IN CPNCRSIE AS NEEDED• SECTION AT PILASTER W120,%,19 FLOOR SEAM . 4.1 -----.�. TYP NOT T �,f of: New PES ASSOCIATES,INC. _ AAArOFa�idA:� 4 tar n �w SUPERIOR cANopY CORPORATION 8{afRA1AiFNAY�YYY►ttAAF�,NAAit#putAsrw•.a....�r++ =WW CLIOERANDFAFAtAS t{t SLIYWAYOUMIdltIJIMMING QUEENSSUFff.NY "� ELlYATt4NSd15�f1D1i.8 tAt•alya'tAMA, t'Sd1-0� BY�EM y22.0;t S DIi OCT 02, F02 12:31 5742692424 PAGE. * TOTAL PAidL03 ** OCT-10-2002 11:56 RHRRONIRN ASSOCIRTES 401 334 4057 P.02/04 ''AHARONIAN ' & A55.00ATES; INC. p1 r C h i• t'e G't• S' E n i n.e.eI s October 10,2002: David Hatin ; Director, Building.and.Cdde-Enforcement Tow6.6f Queensbury Community Development Department 742 Bay. Roy d Oueensbury, NY' :12804 . RE: Proposed CumberlandFarms Convehfance Store—•"SubWay".'Buiiding,'"B" tocated..4t 110 Main Street @ Ryan Street, Queensbury, New York;. Exterior stairway tc,fiasement Level Dear Mr. Hatin:.' Attached pleasa ind a•copy of sketch drawing SK-1 "Part of Plan Q Exterior Stairwell" which provides for a revision to the exterior.stairwell constructibn at this location.. , This letter and sketch plan will hereby allow for the substitution of a,steel'stair with concrete filled steel-pan treads and,aluminum, abrasive tread.nosings in lieu'of the--concrete stair'construction as previously indicated on,the Cbristruction Documents'dated May 04;.2002. revised September.06, 2062. The steel:stairway structure along with the risers'will be.shop primed and finish painted an the field. Steel'shapes and members shall,conform to the requirements-of Standard Specifications for Structural Steel. .A steel pipe railing`will be provided on both'sides of the stair.'wel[.Such railing,system;wilt be 1-1/2fl:dia. schedule'40 pipe confortming'to..'ASTM A53, seoured*with steel•handrail support. brackets.@ W-Ow o.c. max., lagged,toihe-concrete walls at both sides of the well..All rallings,and brackets will'be'shop primed'arid'fiinish painted•in'thefield. All fasteners to be corrosion.resistant and sized'to.accommodate all.imposed loads. Handrail assemblies to be designed to'resist a.Uniform load'.of 50 Ibs. pei'lineal:foot' applied in any directi at ffie'top and a single concentrated toad of 20(}lbs, applied"in on any direction At'any:point•along the tip_ .' Steel to be shop primed with a`modified Alkyd prim G''ar equal to Tnemec No. 1-0.99 . . Green Ntstal Primer, Dupont 681 FD.Primer.or Hempel Primer 1205'and finish painted' 6 Blackstone Va'fley Plaice Suite 100 • Lincoln,:Rhoile Island 02865 T•401-33j-5Q5. • F401 -334.4057 i y OCT-10-2002 11:56 AHARONIAN ASSOCIATES 401 334 4057 P.03f04 with.tw6•(2)•coats•of a high gval4..exterior,alkyd se'M'*Igloss-•finishi Color to be similar to . ' that of e'kterior'brick veneer. If you should:have any further:questioi' or coincems'please feel free•.to:contact me directly: - :Sincerely, Aharonian&.Associates,*Inc. Craig D. Anderson Project Manager. Attachments: SK 1 'Partial Plan-@ Ezter'io'r Stairwell" S -Wanny Paiva ' QUmtaa i irid Farms Plarinin' via.fax: (781)830-4090 _ Andy Boftiird A.V. Bombard Construction;Inc:`. = via.fax- (518)47T2949 :Cutubur,tigd Farms Qucensbury',NY :':' ' NO 2 op C� t Ro rPo 20 --- J f� i " Q Z C r` r Mo 20 1 %�. XXom `' tFj Mai ;_ mow on ♦ �va ;do ��`� • °= My 7 /STEEL STAIR TO � 5ASEMENT i- • - p a,r • �r - :] C a '00 a SIDE OF — — ► rA P.a l r M M2j■ is = ROMOCK w arr i i� }KZow cm PARTIAL PLAN MUM?GEXTERIOR STAMM Y. BUILDING AHA ` MAIN SMUT — CORIMM ROAD ASSOCUMSQUEENSBURY, NY ENGINEERS ARCHITECTS iwianny ratva:-.rwq: .c�uLtfV513URY B.�•� . ..... �.: _ . .. Fade 1 .From: <KBrough@aol.com> To:' <MPaiva@cumberiandfarms.com,> , Date: 8/14/02 11:31 AM r . Subject:- Fwd: QUEENSBURY B.U.H. S " �. Manny, i EP 2 �002 ` (lrtQ�Tlrr I take your reference to B.O.H. as meaning the"Board of Health"or New York State Health Department? The Town-of Queensbury has nothing to do with health permits and Warren county utilizes the New York State Dept. of Health located out of Glens Falls, NY. as it is NOT like Albany County who has it's own Health.Dept. - I'll wait to hear from you, but from the packet that they send out for permitting,you and Andy will need a lot of.information. Such as specs on the equipment (I have spec sheets from Subway corporate) and more. Lot me know....I will not approach the Health Department...FYi..however they have a disclaimer that NO construction should begin PRIOR to obtaining a permit which will need to be in Glen Street Subways, Inc.`s name. _.. ___ _ .._......._._ ....._..............:........................................_.............. ....... Kevin Brough, President Glen Street Subways Ina. ^' 870 State Route 9 Queensbury, NY 12804-1705 518-798-7825 Office 518-798-7827 Store 518-365-7825 Celt qljolgl CC: <KBrough@aol.com> 6-ey+ d' v �. - t4jc� OV, ASSOt-IATES, INC, :. . r c h- i Y .e .c•t S. E rig i n e e rs September 110;2002 David hlatin- .Director, Building and Code Enforcement T6.Wn4:Quee,hsbciry •Community Development'Department ' . 742 Bay Road% :.. Queensbury,'NY. 112804• RE: : Plan.re'view remarks dates MU y 16, 2002'for Proposed Cumberland Farms Converiierice Store—."Subway" Building"B" located at 1-10 Main-Street d@ Ryan.S feet, Queensbury, NY. ..Dear.Mr. ftatin:..,. .: I.rr regard he.--above''referenced.letter,'the following is a respanse to'fhose ' ;.; . items requiring:clarification 1:} Compfefe structural drawings haue been incorporated.'Refer to revised 'Construction Drawings, Superior*Cah6py.Corporatlon sheets 1-5, revised5- . ; 17-02,and PES Associates, Inc. letters,, dated'June 20, 2002 in regard to design'loads'and.roof trussattachment. 2.).'A second means of egress from the public space has:been incorporated into : the east (left,,side)wail: Refer to'revised Constructton.Drawings, Sheet A2:•9' "Floor Plan", revlsed 9-06�02; 3.},.lnte6or stairwell to basement will'have I V treads arid.6-11116•N risers.-Refer to revised Canstructiori.Drawings;Sheet A2.1 "Floor_Plan";'revised 9-06=02. ' 4:}.•.interior stairwell'to basement will have a-1 hour fire resistive rating..R6fer to. revised Constriction Drawings, Sheef A2.1 "Floor Plan" and A4:3 "Walf . Sections"; revised 9-06-02. 5.� Comp[e#e Tire alarm'draWings have-been incorporated. Refer to revised Constuction Drawings, Sheet E1.5 "Fire Protection Plan", revised 7103102. 6.� Plumbfrig Design. Refer to revised Construction Drawings, sheet P1:1 "Plumbing Plan —Upper, Level. Details g•Notes",sheet P1.2"plumbing.Plan —,Basement Level"., revises 9-06-02 and,"Subway"Tuscany Back-up.-sheet#3, revised'6128/01•. ; 7.)' Mechanical.(hvac)-system;design; r Refer to revised Construcfiorl.Drawings, sheet MI.•1 "tti/lechanical'Plan, Details& Motes",:revised 906-02.' b Suite 100 Linco1n,�Rh�ode Island 0'a&6'5 BlaClstcsne Valley Pla:c,e, '• T401'•;333.501 a! F401•334.4057 8.) Com' Idte:fire alarm. and emergency egreis drawings-have been incorporated; Refer'to revised:Construction:Drawings, Sheet E1.5 'Fire Protection Plan', revised 7/03102. 9.) -An'edVelope Comoliarice'Report has been provided. Refdt to letter and report.- dated June 28,2002:.' "10.)' A Handicap.accessible counter has been provided at 34"aboa e finish:. ' floor. Refer to revised Construction btawings,, Front service counter• elevation" on"Subwey"••Tusbany Decor Specs.1 sheet, revised 3:-22-02. 11.). Handicap accessible toilet rooms are provided,.conforming to ANSI:1.17A ' reguiations.',Refdr to revised,Construction Drawings, sheet A2,1 "Floor.Plan" `''- and' A6.1 "Restrobm'•Plans &.Elevations", revised 9-06-02. If you should have any further 06&stions-or.concern' pless'e feel•fcee to contktlma; , d rectly. " Sincerely,: " v .Aharonian.�Associates,.lnc.• CraigQ..Anderson`. Project Managdr Cumbcrknd Farms Quccnsbury,NY*' r Pagc 2 0 _ E- PEA" O IATE% INC. Engineers Surveyors a Construction Land Planning 105 Enterprise Drive Office: (219) 269-6988 Warsaw, IN 48580 Fax: (219)269-2426 June 20, 2002 3&. David Hatin Director Builairi ,ode Enforcement .Towzi of Queensbury 74 Bay k�ad Queensbu�y,.NY 12804-5902 RE: 'B-02-009 Queensb try,Tom' Dear2&. liatin: ' This-is to:certify hat the design loads for the floor system are as follows: 100 psf live load,Mpsf dead load.' If yoa-haue any question please contact us. cerely OF NEW �V Carl A.Demeter, ., S.E. A. 1POFESS10K1`� E DES ASSOCIATES, INC. Engineers• Surveyors-Construction• Land Planning 105 Enterprise Drive Office: (219) 269.5988 Warsaw, IN 46580 Fax: (219)269-2426 June 20,2002 Mt.Francis F. Sheflin Cumberland Farms,Inc. 777 Dedham Street Planning Department Canton,MA. 02021 RE: B-02.008 &B-02-009 Qneensburp,NY Dear Mr. Sheflin: This-is to certify that using two or more iV2" diameter x 1 1/2"Ion- lag bolts with a 3/s"pre- drilled hole in lieu of the(2) 1/2"diameter carriage bolts as shown on the desi-n.drawirfg is acceptable. If you have any question please contact us. �j� 4F NEW Si er � , p,. DEfy�,��Y Dem ,. R, S.F. r' RRQ�`ES54oN�'�"� -AHARO•NIAN, & t�550CI•ATE5',.Nc. - A r c h i t: e•c i s E n g i n' e,:a..r s'' Juno,28,"2002 David'Hahn Direeto>,''�uilding'and Code Enforcement ToA.df`2ueensbury .Community Develop merit•Department : 742 Bajt Road Queensbury,"NY 12804 RE;, Proposed'Cuh be�land'Farms Cbnvenience Store-- "Subway" Building 45' , rsca'ted'at•110'Main Street d.Ryan Street; Queensbury,,MY. ; L'iear'Mr-LHatin; The attached.•Enveiope Contipliance Report.for'the aboue.referenced ptrojectfis : Being_submitted with the understanding.that the following modifications.are hereby made= an integral.pa it of the-original-Oon&u6tion documents,.dated May 24,•2002: • 1.)•instalI'R-13'(3%")-fiberglass batt'insulation.between the vertical.ribs of"the :•4'"ki2' strucfbral steel floor deck.panels, 2,) ,install two (2) layers of 518"type. X, gypsum wallboard on 7180 metal hat: J chartriels, run ning:perpehdicul'ar to and secured to steel deck:panel ribs @, , 24" +o:c. System shall'cover the entire basement ceiling area,'to'provide a 1 hour':€ire resistive rating between the.basement floor'level and the upper-floor ' - level. The option for,.providing spray-on-fireproofing at the basement ceiling. area is hereby'deleted. 3.} liicrease 1" (R-5)insulating drainage board on exterior face of concrete . :. foundation'wall to 2".(R 10) insulating drainage board. Rigid insulation to'be : lnstailed'at entire perimeter of building foundation, extending from top"of . concrete footing to•bottom edge'6f brick shelf. if you.shotild bave*any further•questions or concerns please feel free to contact,me• ; directly: ' 6 Blackstone �V�I(ey Piz Suitt"10U Lincoln, Cthdrie isl'aPd' 0?fiGS TA01•333n5010 F401 .334*'4057 Sincerely, , Aharonian••&Associates,,Inc. Craig JD.-Anderson . Projact Managet'• Attachments: Energy Compliance Report(Proposed New Fork State Energy .' Conservation Construction Code)" r Typical Pre-Engineered Nall-Sysiem Sect oi n,Qetail• CC:. 'Manny_Paiva (Cumbe'rlarid Farms): . - Andy'Bornbard (AV. Bombard Construction, Inc.) • .. .. 1. •• 1' - ...' ., .. •!. ? rt , t .' ,• 'r ` Cumberland Farms•Qup�nsbipy,NY Pagc of 2 ' Envelope Compliance Report . roposed New York State Fnergy Conservation Construction Conde COMeheck-EZ;Software Version 2.3 Release I Data filename:C:\?rogram Files\Check\COMcheck-F—Z\Queensbwy.cck Section 1: Project Information Project Name: Cumberland'Farms-Building "B 110 Main Street @ Ryan Street Quzensbury,Warren County,New York Designer/Contractor. Aharonian&Associates,Inc. 6 Blackstone Valley Place- Suite 100 Lincoln,RI 02865 A.V.Bombard Construction,Inc. 81 New Road East Greenbt;sh,NY 12061 Document Author: Aharonian&Associates,Inc, 6 Blackstone Valley Place.-Suite I00 Lincoln,Ri 02865 Section 2: Gen.er2l Information Building-Location: Warren,New York Climate Zone: 15 Keating Degiee Days(base 65 degrees F): 7635 Cooling Degs'ee Days(base 65 degrees F): 390 Building Use.-Method of Compliance: Whole Building Method Building Type Floor Area Retail Sales,Wholesale Showroom 2000 Figs ect Description(check one):' New Construction ,_,,,Addition Alteration _ Unconditioned Shell(File Affidavit) Seetixon 3: Reiquirements Check st Air Leakage,Component Certification,and Vapor Retarder Requirements Inspection Approved Initial Date (YIN) 'All joints and penetrations are eauiked,gasketed, weather-stripped,or"otherwise sealed Fireplaces installed with tight fitting non-combustible fireplace doors Dampers integral to the building envelope are equipped with,motorized dampers C;aargp doors and loading dock doors are weather sealed Recessed lusting fixtures are sealed or gasketed Windows,doors,and skylights certified as meeting leakage requirements _ Component R-values&U factors labeled as certified Vapor retarder installed Climate-Specifie Requirements Gross Cavity. Cont. Proposed Budget 6amborient-Name/Descrip rea A R-VA lue R-Value TJ-Fact P--Factor _ Sloped Roof: oof:All-Wood Joist/Rafter/Truss 1460 0.0 30.0 0.032 0.01 Cortnents:Asphalt shingles wl fiberglass bast insulation Flat Roof-Metal Roof with Thermal Blocks 540 0.0 22.0 0,044 0.051 Comments:EPDM membrane w/polyiso rigid insulation Exterior W":Composite wall system,14C 1.0 . 2160 ... 0.040 0.074 Comments:BrickSIFS veneer over pre-engineered insulated wall panels Storefront CWihdo�/s): Metal Frame with Thermal Break,Double Pane with Low-E Clear,shgc 0.87,pf 0.50 328 0.560 0.520 Door 1.1 00(Front Entry):Glass,Clear,shgc 0.56 42 --- 0.560- 0.520 Door#101'(Side Entry):Glass,Clear,shgc 0.56 21 0.560 0.520 Door,9 103(Rear Loading):Solid 28 0.190 0.120 Baserrierit*,Wa21:�Solid Concrete or Masonry>8" Furring:Noiie,'Wall Ht 9.5,Depth B.O.9.0' 1710 10.0 0.085 0.099 Comments: 14"poured.concrete w/2" insulating drainage board at exterior face bo&r#061 (Basement): Solid 28 — — 0.190 0.120 1 st Floor.Non-Wood Joistl cuss 1795 0.0 13.0 0.063 0.042 Comments:47'xI2"structural steel deck panels w/fiberglass Batt insulation Fa)Budsat U-factors are used for software baseline calculations ONLY,and are.not cod=-requirements. EUVeIDpe PASSES: 'Design 19%better than code Sectioft 4: Compliapee Statement The proposed envelope design represented in this document is consistent with the building plans,specifications and other calculati4s submitted with this permit application- The proposed envelope system has been designed to meet the Proposed New York State Energy Conservation Construction Code Tequirern=ts.in COMcheck-EZ V rsion 2.3 Release Principal Envelope Designer-Name Signature Date i FOUND. WALL 8" BRICK SHE BRIGK fl�-RHAN "= :� -' r I.. r' 1 -AIR INFILTRATION 5ARRIER 5l8 E9YPSUM YdA._L BOARO .{.•-..._�, ON �/8" MTL. HAT CHANN-L5 i••.: .I (WRA ENTIRE B111LDIN6) a 24" D.G. z`--T I1 Ii---__ OttT51DE FACE OF FOUNDATION TS 3x5:KAL.L STUD - TYP. WALL BELOW- 51-IOWN Vtk5HED (TS 5x5 TYP, 0 C.ORNERS) -' e I` I Va" AIR SPACI= LIME OF S"xa" BRICK SHELF BELOt^i .� •'• .t. `• t - BRIGK F1El=r'� (-4"x5" NOM) I RUNNING BOND ICE/ J. GALV. WALL TIES FARE-FAB. INSTIL. IN ALL PANEL 4 I%2"-EXF'ANI-J-V POLYSTYREN-= INSULATION BARD SANDWICHED Dr=TNEEN 2 LAYER5 -7/16" EXT. _ &RARE 055 5HEATHIN19 - THERMAL RESISTANC r= VALUES (R) 5/5" &YPWM WALL BOARD R a .45 7/16" 055 SHEATHIN& R a 2.0 4. 1/2" EPS INVJLATION R a 20..43 'i/16" 055 SHEATHINS R = :2.0 1 '7/5" AIR SPACE R = 0.5 4" BRICK VENEER R = 0.6 TOTAL A) VALUE R = 26.45 &SYISIOKS Pftw=r rrrld DimrflG rrru. TYPICAL EXTERIOR WALL xUksax freuexxs D<ss SYSTEM SECTION DETAIL D6T8 scar m ombm swe,Cwim =1 6/2e/02 1 1/2"-1'—O` BUILDING — 8 DFAM ar cftJC=,D Dr MAIN STREET — CORINTH ROAD CA. AHARONIAN a RYAN STREET JOB NM Plts Z ASSOCIAM DC. OUEENSBURY, NEW YORK murjAc AvvsrR ARCHITECTS ENGINEERS