2001-358 TOWN OF QUEENSBURY 742 Bay Road, Queensbury,NY 12804-5902 (518).761-8201 Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF COMPLIANCE Permit Number: P20010358 Date Issued: Friday, November 02, 2001 This is to certify that work requested to be done as shown by Permit Number P20010358 has been completed. Tax Map Number: 523400-227-018-0001-008-000-0000 Location: 10 FISHING HOLE Loop Owner: D. BROOKS TEELE Applicant: D. BROOKS TEELE This structure may be occupied as a: By Order of Town Board Septic Alteration Residential TOWN OF QUEENSBURY 4 Director of Building&Code Enforcement , TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building& Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20010358 Application Number: A20010358 Tax Map No: 523400-019-000-0001-032-001-0000 Permission is hereby granted to: D. BROOKS TEELE For property located at: 10 FISHING HOLE Loop in the Town of Queensbury, to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: D. BROOKS TEELE Septic Alteration Residential P.O. BOX 37 Total Value KATTSKILL BAY,NY 12844 Contractor or Builder's Name/ Address Electrical Inspection Agency CRANDALL EXCAVATING Plans &Specifications 2001-358 SEPTIC ALTERATION AS PER PLOT PLAN SPECIFICATIONS $25.00 PERMIT FEE PAID - THIS PERMIT EXPIRES: Thursday,June 05,2003 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town of9uee�' u ; ' es i r . ne 05,2001 SIGNED BY fl \ for the Town of Queensbury. Director of Building&Code Enforcement • • ' Application for Permit—Septic Disposal System •7own of Queensbu►y 742 Bay Rood Queelrsbury,NY 12804 (518) 761-8256 1. OWNER INFORMATION: F��a��rtcs�Hor� 1�0� Office Use Location of installation: ocF of iZ•- r_err %4&ct, t�oi )• Q Tax Map No. Ici ,/ I / v� L� Filo Permit No. 3 V 1— • Fee Paid _ 6 UfiI °vizier's Name: 3) 'i�aZcwK EE t_E Address: 10 14e,Le. Los? K►Trze,KILL_ 4ro TIY iz- 4 2. • INSTALLER'S NAME : Ey.c.A jATt PAC& PHONE NO. 3. RESIDENCE INFORMATION: (circle year of dwelling, indicate II bedroom(s) and multiply i1fv) F I E bedrooms with applicable_gallons per bedroom to equal total daily flo ' � J U N 01 2001 'Year of House: No. of Bedrooms x Computation = Total Daily Flow TOWi, OF OUl=ENssuoa • BUILDING AND CODE 1980 or older x 150 gal/bdnn = " 1980- 1991 _____ x 130 gal/bdrm = 3c1 Q 1991 -present x 110 gal/bdrm = ti= E2 Tc - tcag . A1+4. Garbage Grinder Installed yes . / no V Spa or Whirlpool Installed yes / no ✓ —ro Acces?t-moto r 4. PARCEL INFORMATION: (circle applicable information & indicate measurements) • .. . uwl •' s tu.tQ Q.C9.Untl Wnl,9r. _ 9(IroGk,Ar_JiiipotYiol! P.4Qr�!ill_._nomostic_W�LQ!.►5ip1!ly Otifiri, al wind depth al rrh4rl'rlirj,rh municipal Rolling . 4- fuel 3t*-feel well Sleep slope clay c if well; water supply %slope oilier from I ILL_ c�Y -M i�-�z. E� To fro any septic-systelil _� ►oI- T rde d: absorption is fl. corei. -rE.D5 -c, V � �ASZ*Ttrae L m�To T'other. LAKE rco atlon fast: o e completed try licensed prl fesslvna!engineer or architect) Rale, I5 minute per inch — •EEF.E;z -To i)E.-",te ri t'�,._,+4t-1. TE -r Gorki Er S-t I-oI erw 14A-T i LDE �o tL� t'�jEtt�4 UL�£� Fau-TO -5Y H»t c. ,c-€EVPFtw -r-"1-ET>h 5. PROPOSED SYSTEM: For New Construction: All individual sewage disposal systems must be designed by n licensed professional engineer or architect (unless installed in a Planning hoard approved sulxlivision). Add 250 gallons to the sin of the septic tank and leach field for each Garbage Grinder, Spa or Whirlpool Tub. Septic Tank: 02,000 gallon (min, size 1,000 gal.) - " -1100O GltL r-fti.`TAt rt.t--Dem%E'' Tile Field: each trench f!. Total Systorn Length: fl. 'Seepage Pit(s): number of size of each: f!. by 11. Size of Stone to be used; 1! / depth or thickness Ji'et $Bed System Size: IC) x pAA.N a �At8 EAG-1t 9 Co -Tart-AL Alternative System: length and/or size 6.. HOLDING TANK SYSTEM: (if required) Number of tanks: . / Size of each: gallons /TOTAL Capacity: gallons • Note: Alarm System and associated eioctricai_work_rust.be.inspected_by_a.Town_approved - electrical inspection agency. • 7, SIGNATURE &INFORMATION FOR RESPONSIBLE PERSON (please read) For your protection, please noto that pursuant to Section 136-29 of the Code of the Town of Quoonsbury, any permit or approval granted which is based upon or is granted in rolianco upon any material misrepresentation or failure to make a material fact or circumstance known by or on behalf of an applicant, shall be void. I have rend the regulations with respect to this application and agree to abide by those end all requirements of the Town of Quecusbury Sanitary Sewage Disposal Ordinance. • S gn‘)11.4e.01144. of responsible person to • COMMONWEALTH ELECTRICAL INSPECTION SERVICE,INC. e( Main Office 176 Doe Run Road-Manheim,PA 17545 MUNICIPAL CERTIFICATE - ELECTRICAL APPROVAL Permit No. �^�%,�Cerrt. NO 7 3 5 2 4 Cut-in Card No. Owner / rr�-e ,60- Location . / 7/J G 70 L r. 0 p �A�` Installation Consisting of..S t�� �� � 1JY2JG g''5 merZ6 Installed By 9`e A' Lic.No. The conditions following governed the issuance of this certificate,and any certificate previously issued is cancelled:- This certificate only covers the electrical equipment and installation conditions as of date. Upon the introduction of additional equipment or alterations,application shall be promptly made for inspection. Inspectors of this Company shall have the privilege of makin ections at any time, and if its rules are violated,the Company shall have the right to revoke thi ertif ate. Date //—Z / INSPECTORMember N.F.P.A..I.A.E.I. TOWN OF QUEENSBURY BUILDING & CODE ENFORCEMENT 742 Bay Road : ,n\ Queensbury NY 12804 U(J (518) 761-8256 SEPTIC DISPOSAL SYSTEM INSPECTION Name ' 1 G c.& Location F=i3k) n 1--,o6- 1--6'60 Date tb 151 IS ( Permit # 0 (---71)13 SOIL TYPE: Sand-Loam-Clay- Results of Percolation Test- (if applicable) Rate-Minute/Inch TYPE OF SYSTEM: ABSORPTION FIELD: Tot.l Length Length of each tr-nch Depth of trenches Size of stone SEEPAGE PITS: Nu• ber- Size - ft x ft. Stone sib PIPING: Size Type Bldg. to Tank rbile Tank to Dist. Box - 54-715 Dist. Box to Field ' Openings Sealed? , No Partial LOCATION/SEPARATIO • Foundation to Tank feet Foundation to Absorttion . feet Separation of Pits . eet Conforms as per P10 P1 an es No LOCATION OF SYSTEM IN PROPERT . (circle one) Front - Rear - Left bide - Right Side Middle Front - Middl : Rear COMMENTS: . ✓& p. Ai4 C - , L, . ( C / °K r)oc -p re-Si 0K- SYSTEM.USE APPROVED: YES NO Arrived: Departed: _.'/S / Building Inspector TOWN OF QUEENSBURY B ILDING & CODE ENFORCEMENT 742 Bay Road Queensbury NY 12804 (518) 761-8256 SEPTIC DISPOSAL SYSTEM INSPECTION Name 1 C��6: Location PLo- '&Uo6 Date __ 2-5 v/ Permit # O f - 35-8 SOIL TY • -nd- oam-Clay- Results o Percolat,"on Test- (if applica le) Rate- inute/Inch TYPE OF SYST : ABSORPTION FIE : Total Lengths /?6 Length of each t ench r. . Depth of trenches 1 Size of stone �cL "C . SEEPAGE PITS: Numbe, - Size - ft. x ft. Stone size PIPING: ize Type Bldg. to Tank Tank to Dist. Box z —7,.'\ Dist. Box to Field/P" A • _ Openings Sealed? Yes No . artia ! LOCATION/SEPARATIO` • Foundation to Tank -et %42Foundation to Absorptions ZLi-/y.fe-t . . Separation of Pits __ feet Conforms as per Plot Plan 4110, No LOCATION OF SYSTEM ON PROPER . (circle n: Front Rear - Left Side - Right Side Middle -. t - ddle Rear COMMENTS: �(A.c.._ 156e_ aNC y. . . Calk l d rci- -(2 SYSTEM.USE APPROVED: • YES NO Arrived: f , Departed: /AIL cylL,, Building Inspector �--DEL — LYtT Wastewater Disposal System: Basis'of Design The existing Teele residence is a three(3)bedroom home served by a holding tank system installed in approximately 1988 when the pre-existing camp was renovated. Evidently, at that time the applicable setback standards precluded the placement of a conventional absorption system.The holding tank system installed consists of three(3)- 1000 gallon precast concrete tanks in series located in a lawn area just east of the house. This plan proposes a replacement system in compliance with the Town of Queensbury On-Site Sewage Disposal Ordinance—Chapter 136. With the approval of the Eljen In-Drain system by the New York State DOH(March 1999)an absorption system requiring less area can be installed on this site and still meet the current setbacks to neighboring wells,property lines, and the shoreline of Lake George. The system as proposed herein consists of reuse of two of the holding tanks as the septic tank, a duplex pump pit and a fill absorption field using Eljen In-Drain units. This replacement system will meet all setback requirements and will comply with today's standards for hydraulic capacity and material specification. Hydraulic Loading: 550 gallon per day system design With a daily flow based on 110 gallons/day/bedroom the system could accommodate a five(5)bedroom home. As it exists the residence has 3 bedrooms. Soils Analysis: Raised(Fill) System The proposed replacement system will be a raised(fill)system at a location meeting the Town of Queensbury standards (100' min.)from the lake. The actual absorption field location (300') would also satisfy the lake setback distance even if this was considered a new system. In consideration of the fill system standards three test holes within the area of the proposed absorption field indicate conditions suitable for a fill system,i.e.-three(3') feet of naturally occurring soil exists above an impervious layer or seasonally high groundwater. The soils consisted of 24" to 27" of sand to sandy-silt material before encountering a silty soil to 36" and deeper. One of the holes had evidence of • water at 25". There was no evidence of mottling in any of the holes within the 15" to 18" of sandy loam. It is proposed that the sand to sandy-silt soils will be supplemented with 24"of specified fill soil(thus meeting the 3' separation requirement)to be placed so that it will stabilize prior to the installation of the Eljen bed system. Percolation Tests: Native soils Two(2)perc tests were conducted within the native soils in the area of the proposed field. Results were a stabilized rate of 5 minutes/inch for PT#1 and 15 minutes/inch for PT#2. The fill soils will no doubt have a perc rate of 5 minutes/inch but as this raised (fill)system is using the native soils in part for the treatment zone the design is based on a perc rate of 11 -15 min./inch. Q/a Design Criteria: Septic Tank size: Minimum size for a five bedroom design is 1500 gallons as per NYS Dept. of Health standards. The proposed tank is a combined 2000 gallon capacity with two 1,000 gallon tanks in series. Effluent Pump Station: The system will require a duplex effluent pump system capable of 6 gpm at 15' TDH. The pump pit shall be a precast concrete structure(or approved equal)with the control panel wired for placement within the house. An audible alarm shall be provided with the controls. The dosing volume of the pump cycle shall be equal to 75 to 100% of the force main and distribution pipe capacity. This volume is calculated to be approximately 85 gallons. Set pump controls to pump 80±gallons per cycle. Pump will operate approximately 7 cycles per 'design flow' day. The third existing 'holding tank° will be connected by a 4" PVC pipe to the pump pit to serve as an overflow tank. This will allow the pump pit to be sized for the dosing volume while the overflow tank can handle emergency storage. Force Main: Piping to be 1'h" HDPE pipe to a distribution box at the raised system site. The force main shall self drain back to the pump pit upon pump shutdown. Raised Disposal Field: The system shall consist of'Eljen In-Drain units: Type B', installed in a bed configuration within the stabilized fill soils. The daily flow rate of 550 gallons requires 961f of Eljen Type B units at the design application rate. Use 2 runs of 481f each in a bed configuration to total 961f of Eljen units. The separation distance between the Type B units shall be 2'. The area required for this absorption field shall be approximately 10' x 50'. SITE LOCATION MAP SCALE: 1" = 2,000' 7000 GAL HEAVY DUTY STRUCTURE TO BE SUPPLIED BY THE FORT MILLER CO. OR APPROVED EQUAL SEE DESIGN NOTES FOR PROBE SETTINGS PUMPJ 'D" GALVANIZED- i (SEE SPECS) MALE N.P.T. OUTLET OSP J3 DISCHARGE TO OVERFLOW CONNECRON PIPE \ NOTE 11, ALL DIMENSION ARE APPROXIMATE AND ARE NOT TO BE USED FOR CONSTRUCTION PUPOSES N07E JZ VERIFY NTH FACTORY THAT THE PUMP BOND APPLIED IS DIMMENSIONALLY SUITABLE FOR USE V4774 THIS SYSTEM IN THE DIAMETER AND DEPTH REQUIRED. PUMP INSTALLATION DETAIL NOT TO SCALE GENERAL SANI TAR Y NOTES, 1. MAINTAIN 700' SEPARATION BETWEEN SEPTIC SYSTEM AND ANY WELL. CONTRACTOR SHALL VERIFY THE LOCATION OF ALL EXISTING WELLS PRIOR TO CONSTRUCTION. 2. MINIMUM SEPARATION BETWEEN SEPTIC TANK AND BUILDINGS SHALL BE 10 FEET. 3. MINIMUM SEPARATION BETWEEN EDGE OF BED AND BUILDINGS SHALL BE 15 FEET. 4. MINIMUM SEPARATION BETWEEN PROPERTY LINE AND EDGE OF BED OR TOE OF FILL (RAISED SYSTEMS) SHALL BE 10 FEET. 5. MINIMUM SEPARATION BETWEEN WELL AND SEPTIC TANK TO BE 50 FEET. 6. ALL CONSTRUCTION TO BE IN COMPLIANCE WITH THE NEW YORK STATE SANITARY CODE. 7. REQUIRED INSPECTIONS (TO BE PERFORMED BY PROFESSIONAL ENGINEER): A) PRIOR TO PLACEMENT OF SEPTIC TANK OR COMMENCEMENT OF THE ABSORPTION FIELD CONSTRUCTION. B) DURING THE INSTALLATION OF ANY REQUIRED FILL MATERIAL. C) PRIOR TO BACKFILLING BED. D) FINAL INSPECTION UPON COMPLETION OF THE SYSTEM. 8. CONCRETE SAND SHALL BE A MEDIUM TO COARSE SAND WITH AN EFFECTIVE SIZE OF 0.25 TO 2.0 MM AND NO MORE THAN 5% PASSING A #200 SIEVE. 9. WHEN THE BED AREA HAS HAVE BEEN EXCAVATED, THE SIDES AND BOTTOM SHALL BE RAKED TO SCARIFY ANY SMEARED SOIL SURFACES. 10. CONSTRUCTION EQUIPMENT NOT NEEDED TO CONSTRUCT THE SYSTEM SHOULD BE KEPT OFF THE AREA TO BE UTILIZED FOR THE ABSORPTION FIELD SYSTEM TO PREVENT UNDESIRABLE COMPACTION OF THE SOILS. 11. EACH DISTRIBUTION LINE SHALL CONNECT INDIVIDUALLY TO THE DISTRIBUTION BOX AND EXIT AT THE SAME SLOPE FOR THE FIRST 5 FEET TO 10 FEET FROM THE BOX (1/8" PER FOOT). 12. THE DISTRIBUTION BOX SHALL BE SET LEVEL AND ARRANGED SO THAT EFFLUENT IS EVENLY DISTRIBUTED TO EACH DISTRIBUTION LINE. ADEQUATE PROVISIONS SHALL BE TAKEN TO ASSURE STABILITY AND PROVIDE ACCESS FOR INSPECTION OF THE DISTRIBUTION BOX. 13. THE PIPES CONNECTING THE DISTRIBUTION BOX TO THE DISTRIBUTION LINES SHALL BE TIGHT JOINT CONSTRUCTION LAID ON UNDISTURBED EARTH OR PROPERLY BEDDED THROUGHOUT ITS LENGTH. 14. THE SYSTEM DESIGN DOES NOT INCLUDE PROVISIONS FOR GARBAGE GRINDERS. IN THE EVENT THAT GARBAGE GRINDERS ARE TO BE INSTALLED, THE CONTRACTOR SHALL NOTIFY ENGINEER PRIOR TO SEPTIC INSTALLATION FOR NECESSARY MODIFICATIONS. 15. FOOTING DRAINS, SUMP PUMPS OR WATER SOFTENER DISCHARGES SHALL NOT BE CONNECTED INTO THE SEPTIC SYSTEM. 16. CONTRACTOR TO COMPLY WITH ALL O.S.H.A. AND OTHER STATE AND LOCAL SAFETY REQUIREMENTS DURING CONSTRUCTION. 17. AS PER NEW YORK STATE INDUSTRIAL CODE 53: CALL 1-800-962-7962 TO LOCATE BURIED CABLES, OR OTHER UNDERGROUND UTILITIES, NO LESS THAN TWO, OR MORE THAN TEN WORKING DAYS, PRIOR TO DIGGING, DRILLING, EXCAVATING, DRIVING POSTS, ETC. WASTEWATER DISPOSAL SYSTEM. BASIS OF THE EXISTING TEELE RESIDENCE IS A THREE (3) BEDROOM HOME SERVED BY A HOLDING TANK SYSTEM INSTALLED IN APPROXIMATELY 1988 WHEN THE PRE-EXISTING CAMP WAS RENOVATED. EVIDENTLY, AT THAT TIME THE APPLICABLE SETBACK STANDARDS PRECLUDED THE PLACEMENT OF A CONVENTIONAL ABSORPTION SYSTEM. THE HOLDING TANK SYSTEM INSTALLED CONSISTS OF THREE(3) - 1000 GALLON PRECAST CONCRETE TANKS IN SERIES LOCATED IN A LAWN AREA JUST EAST OF THE HOUSE. THIS PLAN PROPOSES A REPLACEMENT SYSTEM IN COMPLIANCE WITH THE TOWN OF QUEENSBURY ON -SITE SEWAGE DISPOSAL ORDINANCE - CHAPTER 136. WITH THE APPROVAL OF THE ELJEN IN -DRAIN SYSTEM BY THE NEW YORK STATE DOH (MARCH 1999) AN ABSORPTION SYSTEM REQUIRING LESS AREA CAN BE INSTALLED ON THIS SITE AND STILL MEET THE CURRENT SETBACKS TO NEIGHBORING WELLS, PROPERTY LINES, AND THE SHORELINE OF LAKE GEORGE. THE SYSTEM AS PROPOSED HEREIN CONSISTS OF REUSE OF TWO OF THE HOLDING TANKS AS THE SEPTIC TANK, A DUPLEX PUMP PIT AND A FILL ABSORPTION FIELD USING ELJEN IN -DRAIN UNITS. THIS REPLACEMENT SYSTEM WILL MEET ALL SETBACK REQUIREMENTS AND WILL COMPLY WITH TODAY'S STANDARDS FOR HYDRAULIC CAPACITY AND MATERIAL SPECIFICATION. HYDRAULIC LOADING: 550 GALLON PER DAY SYSTEM DESIGN WITH A DAILY FLOW BASED ON 110 GALLONS/DAY/BEDROOM THE SYSTEM COULD ACCOMMODATE A FIVE (5) BEDROOM HOME. AS IT EXISTS THE RESIDENCE HAS 3 BEDROOMS. SOILS ANALYSIS: RAISED (FILL) SYSTEM THE PROPOSED REPLACEMENT SYSTEM WILL BE A RAISED(FILL) SYSTEM AT A LOCATION MEETING THE TOWN OF QUEENSBURY STANDARDS (100' MIN.) FROM THE LAKE. THE ACTUAL ABSORPTION FIELD LOCATION (300) WOULD ALSO SATISFY THE LAKE SETBACK DISTANCE EVEN IF THIS WAS CONSIDERED A NEW SYSTEM. IN CONSIDERATION OF THE FILL SYSTEM STANDARDS THREE TEST HOLES WITHIN THE AREA OF THE PROPOSED ABSORPTION FIELD INDICATE CONDITIONS SUITABLE FOR A FILL SYSTEM, I.E.- THREE (3) FEET OF NATURALLY OCCURRING SOIL EXISTS ABOVE AN IMPERVIOUS LAYER OR SEASONALLY HIGH GROUNDWATER. THE SOILS CONSISTED OF 24" TO 27" OF SAND TO SANDY -SILT MATERIAL BEFORE ENCOUNTERING A SILTY SOIL TO 36" AND DEEPER. ONE OF THE HOLES HAD EVIDENCE OF WATER AT 25 THERE WAS NO EVIDENCE OF MOTTLING IN ANY OF THE HOLES WITHIN THE 15" TO 18" OF SANDY LOAM. IT IS PROPOSED THAT THE SAND TO SANDY -SILT SOILS WILL BE SUPPLEMENTED WITH 24"OF SPECIFIED FILL SOIL (THUS MEETING THE 3' SEPARATION REQUIREMENT) TO BE PLACED SO THAT IT WILL STABILIZE PRIOR TO THE INSTALLATION OF THE ELJEN BED SYSTEM. PERCOLATION TESTS: NATIVE SOILS TWO (2) PERC TESTS WERE CONDUCTED WITHIN THE NATIVE SOILS IN THE AREA OF THE PROPOSED FIELD. RESULTS WERE A STABILIZED RATE OF 5 MINUTES/INCH FOR PT#1 AND 15 MINUTES/INCH FOR PT#2. THE FILL SOILS WILL NO DOUBT HAVE A PERC RATE OF 5 MINUTES/INCH BUT AS THIS RAISED (FILL) SYSTEM IS USING THE NATIVE SOILS IN PART FOR THE TREATMENT ZONE THE DESIGN IS BASED ON A PERC RATE OF 11 - 15 MIN./INCH. DESIGN CRITERIA: SEPTIC TANK SIZE: MINIMUM SIZE FOR A FIVE BEDROOM DESIGN IS 1500 GALLONS AS PER NYS DEPT. OF HEALTH STANDARDS. THE PROPOSED TANK IS A COMBINED 2000 GALLON CAPACITY WITH TWO 1,000 GALLON TANKS IN SERIES. EFFLUENT PUMP STATION: THE SYSTEM WILL REQUIRE A DUPLEX EFFLUENT PUMP SYSTEM CAPABLE OF 6 GPM AT 15' TDH. THE PUMP PIT SHALL BE A PRECAST CONCRETE STRUCTURE (OR APPROVED EQUAL) WITH THE CONTROL PANEL WIRED FOR PLACEMENT WITHIN THE HOUSE. AN AUDIBLE ALARM SHALL BE PROVIDED WITH THE CONTROLS. THE DOSING VOLUME OF THE PUMP CYCLE SHALL BE EQUAL TO 75 TO 100 % OF THE FORCE MAIN AND DISTRIBUTION PIPE CAPACITY. THIS VOLUME IS CALCULATED TO BE APPROXIMATELY 85 GALLONS. SET PUMP CONTROLS TO PUMP 80+ GALLONS PER CYCLE PUMP WILL OPERATE APPROXIMATELY 7 CYCLES PER DESIGN FLOW DAY. THE THIRD EXISTING 'HOLDING TANK' WILL BE CONNECTED BY A 4" PVC PIPE TO THE PUMP PIT TO SERVE AS AN OVERFLOW TANK. THIS WILL ALLOW THE PUMP PIT TO BE SIZED FOR THE DOSING VOLUME WHILE THE OVERFLOW TANK CAN HANDLE EMERGENCY STORAGE. FORCE MAIN: PIPING TO BE 1�" HDPE PIPE TO A DISTRIBUTION BOX AT THE RAISED SYSTEM SITE. THE FORCE MAIN SHALL SELF DRAIN BACK TO THE PUMP PIT UPON PUMP SHUTDOWN. RAISED DISPOSAL FIELD: THE SYSTEM SHALL CONSIST OF 'ELJEN IN -DRAIN UNITS. TYPE B', INSTALLED IN A BED CONFIGURATION WITHIN THE STABILIZED FILL SOILS. THE DAILY FLOW RATE OF 550 GALLONS REQUIRES 96LF OF ELJEN TYPE B UNITS AT THE DESIGN APPLICATION RATE. USE 2 RUNS OF 48LF EACH IN A BED CONFIGURATION TO TOTAL 96LF OF ELJEN UNITS. THE SEPARATION DISTANCE BETWEEN THE TYPE B UNITS SHALL BE 2'. THE AREA REQUIRED FOR THIS ABSORPTION FIELD SHALL BE APPROXIMATELY 10' X 50'. FILL SYSTEM INSTALLATION CONSTRUCTION NOTES, 1. WHEN PLACING FILL ON TOP OF EXISTING GRADE, ORGANIC DEBRIS, INCLUDING LEAVES, ROOTS AND OTHER PLANT FORMS, SHALL BE REMOVED 1. CONSTRUCTION OPERATIONS SHALL BE IN COMPLIANCE WITH THE RECOMMENDED PRIOR TO THE PLACEMENT OF THE FILL AND THE NATURAL SOIL PLOWED OR STANDARDS FOR EROSION CONTROL AS DETAILED IN THE "NEW YORK GUIDELINES SCARIFIER FOR EROSION AND SEDIMENT CONTROL". 2. THE SOIL USED FOR FILL SHALL BE WELL -GRADED LOAMY SAND OR WELL - GRADED LOAMY SANDY GRAVELS AND SHOULD CONTAIN A MINIMUM OF TWELVE PERCENT (12X) OF SILTS OR CLAYS CONTAINING NO ORGANIC DEBRIS OR NO SOLID OBJECT LARGER THAN THREE (3) INCHES IN DIAMETER, AND THE FILL SHALL BE ALLOWED TO STABILIZE NATURALLY FOR A LEAST SIXTY (60) DAYS. 8% MAX. SLOPE 30" MAX. 4" PERF. PIPE 10"-,17" f`� 12- '1 CONCRETE SAND -/ L24" USABLE SOIL PERCOLATION RATE 1-30 MIN./IN. NOT TO SCALE SUITABLE BACKFILL PLUS A MIN. 4" 3. SUFFICIENT FILL MUST BE INSTALLED TO ENSURE A MINIMUM OF TWO (2) FEET TOPSOIL & SEED BETWEEN ANY TRENCH BOTTOM AND MAXIMUM SEASONAL GROUNDWATER, IMPERVIOUS MATERIAL OR BEDROCK. THIS SEPARATION MUST BE THREE (3) GEO TEXTILE COVER FEET WITHIN ONE THOUSAND (1,000) FEET OF LAKE GEORGE. FABRIC 4. ONLY ABSORPTION FIELDS SHALL BE USED AS THE LEACHING FACILITY IN FILL SYSTEMS. 5_ A CHANNEL OR DIVERSION SYSTEM SHALL BE PLACED ABOUT THE FILL SYSTEM IN THE UP -SLOPE DIRECTION AND OF SUFFICIENT LENGTH TO DIVERT SURFACE AND SHEET WATER RUNOFF AROUND THE FILL SYSTEM. ;s. 6" MIN. 12"� 6. THE TOP OF FILL OVER THE LEACHING FACILITY SHALL BE CROWNED OR SLOPED TO ALLOW NATURAL SURFACE RUNOFF AND SHALL BE SEEDED. 3' MIN. TO IMPERVIOUS STRATA, BEDROCK 7. SIDE SLOPES OF FILL SHALL BE GRADED TO A SLOPE NOT STEEPER THAN ONE OR DWATER SEASONAL HIGH GROUND (1) VERTICAL ON THREE (3) HORIZONTAL. * SEE NOTES B(1 AND (5) MAP REFERENCE- 1) MAP ENTITLED: "MAP OF PORTION OF LANDS OF STEWART, TEELE & MERCLE" DATED MARCH 20, 1972 AND LAST REVISED EXISTING 1,000 GALLON JUNE 14, 1976 AS PREPARED BY COULTER & McCORMACK. CONCRETE TANKS NO TE• 1) FIELD MONUMENTATION NOTED ON THIS PLAN AS PER MAP EXISTING BUILDING REFERENCE No. 1 SEWER #1 ---- - INSTALL NEW 4" PVC SDR 26 #2 INSTALL NEW DUPLEX PUMP PIT ELIMINATE EXISTING CONNECTION 1-1/2" HDPE FORCE MAIN #3 TO ABSORPTION FIELD `` OVERFLOW PIPE SEPTIC TANK CONFIGURATION NOT TO SCALE BASEMAP-BROOKS TEELE LAKE GEORGE.DWG L A K E_ 000000 WOOD DOCK HOAT USE ELJEN IN -DRAIN DIMENSION & ! F'ECIFICATION SHEET TYPE B IN -DRAIN UNIT 36" W x48" L x7" H LARGE CORE WIDTH 1.250" SMALL CORE WIDTH .750" DESIGN FLOW LESS THAN 1,000 GAL/DAY LARGE CORE WIDTH 90% VOIDS / 50 GAL. DISTANCE TO SEASONAL HIGH WATER TABLE, IMPERVIOUS STRATA OR BEDROCK 2' MINIMUM DEPTH OF TRENCH 29" MINIMUM DEPTH OF COVER OVER DISTRIBUTION PIPE 6" MINIMUM SETBACKS: HOUSE 10 FEET MINIMUM WELL 100 FEET MINIMUM PROPERTY LINE 10 FEET MINIMUM ALL SETBACKS ARE MEASURED FROM THE EDGE OF CONCRETE SAND IN SITU SOIL INTERFACE PIPE ENDS TO BE CAPPED BACKFILL 12" MINIMUM 6" CONCRETE SAND DIRECTLY BELOW SURROUNDING THE NEW YORK DEPARTMENT OF TRANSPORTA- SIDES OF THE IN -DRAIN UNITS FOR TION CONCRETE SAND SPECIFICATION ABSORPTION TRENCHES 703-07 DISTRIBUTION PIPE PERFORATED 4" DISTRIBUTION PIPE NON -PERFORATED 4" GEOTEXTILE COVER FABRIC TYPAR 3401 PROVIDE WITH THE IN -DRAIN UNITS TRENCH WIDTH 4' SPACING BETWEEN IN -DRAIN ROWS 4' ABSORPTION TRENCH (See figures 3, 5) 2' ABSORPTION BED CONCRETE SAND DEPTH DIRECTLY 6" MINIMUM BELOW IN --DRAIN UNITS CONCRETE SAND AT THE SIDE OF 6" ABSORPTION TRENCH IN -DRAINS 12" ABSORPTION BED ACCEPTABLE SOIL PERCOLATION RATE 1-60 MIN/IN ABSORPTION TRENCH 1-30 MIN/IN ABSORPTION BED ACCEPTABLE SOIL PERCOLATION RATE GRAVITY / PUMP / SIPHON ALL APPENDIX 75-A SEPARATION REQUIREMENTS ARE APPLICABLE CONCRETE SAND BED 10' x 50' (MIN.) ------ 36.------------------ I24 10' ELJEN IN -DRAIN UNIT - TYPE 'B' 48 LF PER RUN WITH 4" PERFORATED PVC PIPE 12 TYPE 'B' UNITS EACH ABSORPTION SCALE: 1" - 10' - #1 DISTRIBUTION BOX 1-1/2" HDPE FORCE MAIN FROM PUMP PIT RECEIVED 4" SOLID PVC PIPE JUN 0 4 2001 TOWN OF QUEENSBURY BUILDING AND CODE GRADE NOTE: 1. PIPE JI ASPHALTIC TO BE SE 'MM MATERIALS OR 12" MIN REMOVABLE COVER -7 2. INVERT ELEVATIONS OF ALL / OUTLET PIPES MUST BE EOUAL. 3. THE SLOPE OF OUTLET PIPES BETWEEN THE DISTRIBUTION BOX AND THE DISTRIBUTOR LATERALS F BAFFLE INVEf T ' SHOULD BE 118' PER FOOT. INLET 2"MIN ELEV. O OUTLET CONTRACTOR TO USE SPEED LEVELERS AS SUPPLIED BY FORT MILLER TO EQUALIZE FLOW. 12" MIN CLEAN SAND OR PEA GRAVEL 1##1 DISTRIBUTION BOX NOT TO SCALE J"V �O Q o�- 1�6 I n p AREA=/'� J� CAMP 4B, 71 7f SQ. FT . ! I . CAMP V WELL CASING FILL SYSTEM AS PER TOWN PORCH OF QUEENSBURY STANDARDS. O TWO FEET OF FILL MATERIAL ABOVE: NATIVE SOILS. w N ,001E I LANDS N/F OF 7O ,I Q N85 c3 I FORGE C. JAMES DEED LINE EXISTING WASTEWATER SYSTEM 0.3 t GRAVEL OR;vE CONSISTS OF (3) 1,000 GALLON Nm HOLDING TANKS IN SERIES. PROPOSED > uS F-- ---- i � - \ SOILS A-4A l..Y 51 S SYSTEM WILL USE TANKS #1 AND #2 AS SEPTIC TANKS AND #3 AS AN OVERFLOW i «=_ �`--- HOLDING TANK FOR THE PUMP PIT. z! M.�3 , --- ® ±] I 10' 1 t - `T,L-v �OL� ELIMINATE CONNECTIONS BETWEEN TANKS �� #2 AND #3. W J / /�l - - _ _ I �j" Q 2 - t _rwuc wTE�'1" -' I EXISTING SEPTIC (HOLDING) , ' 1 Rt r, 1 pf �r� p TANKS: (3) 7,000 GALLON S77, 02 E �- \ 178. Q' / tl I \ l '' ClUE-ENSBURY 6 Lf 1"T P L�Ir�LE. IiRTMEiVT PRECAST CONCRETE TANKS I m? 'Id on our limited examination, IRON�_-_ o / menu shall PIN SET `� l'J ABSORPTION BED: compliance Wlth our comments ��� 10' x 50' CONCRETE r1 not be construed as indicatingthe \ PUMP PIT SAND (SEE DETAIL) plan and speciiica 'ons are �-'' e in full O RC \MAIN --j cornplianre With the de ADDITION F DISTRIBUTION ,...._:; kApE \ BOX a DECK G a FORGE ASPHALT \\ O 46 WEA CUP :�,_ A ExlsnN OVERFLOW COTTAGE PIPE FROM OAK£ G PARKING `�.\` (SETS(\ CONC.) W w LANDS N/F OF ANNA BAR THEL BOOK 425 OF DEEDS AT PAGE 789 i00 F5NCI SE ------------------ ram' W Z C)O ```````_'------ GRAVEL DRIVE _ _ ----------- N W ��'�� N77.OZ'W STONE MASONRY WALL ,I `t- 340.5' `� q RAMP GARAGE ((�� `� F WE.L T� iSSU LANDS N/F OF CASING ETHEL G. APPLEBAUM & SERNA G. BOYD BOOK 337 OF DEEDS AT PAGE 109 MAY 3 1 2001 SEPTIC PLAN THE ENV vNmENTAL DES1f1w] TNEPSHIP SCALE: 1 " = 20' w P4o 0 00 rzq >-, 4m � Z>.4 U) h J � z W � A ° Li m W W �rZ E-+ w W w V) L Cl V '-' z I- H Z. m w WIC Fq Ix j Z 0 Zo V Z zmA wj qe m w O 0inz IC 10 W O� wIzw Z �- ~ z F U Z O V) U W a Q 0 V) Z Ld z L.J ~ 0 O yj Z r, Q m LL1 Q Q 0 z 0 LL I �* w� Mo z N 4i LICE ` BURYp a �1�,;-E` ,j`�i„y 11 DING & 7Q PT. WED BY Nvir b zLLj o LLJ ~ ~ z _I O U Uz _Dj W (� V) 0 w Q