Loading...
2001-515 Of TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: P20010515 Date Issued: Tuesday, December 18, 2001 This is to certify that work requested to be done as shown by Permit Number P20010515 has been completed. Tax Map Number: 523400-295-018-0002-010-000-0000 Location: 133 AVIATION Rd Owner: UNITED CEREBRAL PALSY ASSOC. OF THE TRI CO INC Applicant: PROSPECT SCHOOL NORTH This structure may be occupied as a: By Order of Town Board Commercial Addition TOWN OF QUEENSBURY 7 Director of Building&Code Enforcement g �� TOWN OF QUEENSBURY Fig y 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building& Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20010515 Application Number: A20010515 Tax Map No: 523400-295-018-0002-010-000-0000 Permission is hereby granted to: UNITED CEREBRAL PALSY ASSOC. OF THE TRI For property located at: 133 AVIATION Rd • in the Town of Queensbury, to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: UNITED CEREBRAL PALSY ASSO Commercial Addition 365,333.00 133 AVIATION Rd Total Value 365,333.00 QUEENSBURY,NY 12804 Contractor or Builder's Name/ Address Electrical Inspection Agency V & H CONSTRUCTION.INC. 746-1520 PO BOX 126 FORT EDWARD.NY Plans &Specifications 2001=515--PROSPECT--SCHOOL_NORTH- 2,740 SQ FT COMMERCIAL ADDITION AS PER PLOT PLAN SPECIFICATIONS S383.60 PERMIT FEE PAID- THIS PERMIT EXPIRES: Friday,July 12,2002 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer. of the Town of Queensbury before the expiration date.) Dated at the Town of Queensb ; Thurs s ay,July 12,2001 SIGNED BY /4 for the Town of Queensbury. Direct r of Building& t!•a orcement Building Permit Application '?'own ofQucensbury— Dept of Community I)cvclopment, 7,12 13ay Road, Quccnsbury, NY (518) 761-8256 A permit must be obtained before beginning construction. Permit File No. 51.5 No inspection will be made until applicant has received a lee Paid $ valid building permit. All applicants' spaces on Ibis Itec. Fee Paid $ _3 ✓ ,GC) application must be completed and must appear on the Reviewed By: application form. Applicant: V(F (-I en I\ -24— , IN L _ Owner: 9"los Address: ,�c)�((ric�.� l��e�CC,tx:�= Address: j, 3 ,4v/a g _ Phone# (5S ) 79 - /s—,90 Phone if ( ) - 1 .641� Property Location: Lot Number: / House Number / TOW 2007 Subdivision Name: Tax Map Number: � " 4 QVFFN ❑ Ncw Building: residence /commercial Estimated Market Valuc.of Construction: $ tS Addition: residence/ commercial if an Addition, what will use of new addition be? U Alteration: residence/ commercial O No change to exterior size: residence/com'I U Other work(describe • Cheek Occupancyln forma lion I'' Moor 211Floor ) Crt floor 'Total Below sq. I•t. sq. II, sq. I•I. Square Feet ❑ Single family dwelling ❑ Two fatnil dwellin ❑ Townhouse u Multifamily dwelling #I of units ❑ Office ❑ Mercantile u Manufacturing — — ❑ 1 car detached garage _ u 2 car detached garage _ CI 3 car detached garage ❑ 1 car attached garage ❑ 2 car attached garage U 3 car attached garage ---- u Storage building- ---.. ----------- --- ----- --- coinmeteial U Storage building - residential Other — L/0 -- Will any second-hand or ungraded lumber be used'? If so, for what'? k)C) Type of I?eating System: electric/ oil / gas/wood /forced hot air/ baseboard/other: Number of Fireplaces to be installed (I) Number of II'oodtiIores to be installed • List below the person(s) responsible (ilr supervision of work as regards to building codes: Name Address Phone Number Builder \/k'\ • 796 -/SRO Plumber �( c(-0ry 1c-k ti _ • Mason tv`rcc1-e- Electrician Pc*\-: \t- `Ou'- ec1nrntign: please sign below tiller you have carefully react the statement:: • To the best of my knowledge the statements contained in this application, together with the plans and specifications submitted, arc a true and complete statenre nt of all proposed work to he done on the described premises and that all provisions ol'Ihe !Wilding('ode, the honing Ottlinanee and a:l other laws pertaining to the proposed work shall he complied with, whether specified or noted, and that such work is authorized by the owner. Further, it is understood that I/we shall submit, prior to a ('crlificatc ol•Occupancy or Certificate of Compliance being issued, as requested by the 'honing Administrator or Director of Building and('odes,an As Built Surrey by a licensed surveyor;drawn to scale,showing actual location of all new construction. Signature: /1_0,0Z;V:4,7e2 owner,owner's agent,architect,contractor • • Application for Permit— Septic Disposal System Town of Queensbury 742 Bay Road Queensbury,NY 12804 (518) 761-8256 1. OWNER INFORMATION: pp � Office Use - Location of installation: c \ .�,A Q c - - O�C.C14S J-' o File Permit No. Tax Map No. / • / • /� l • FeO Paid • Owner's Name: �` 'C OS ' s( \oo \ • Address: \ A U. ta.\va r J q i)e eu . C • • 2. ••INSTALLER'S NAME : a eo tV ti O NC (10 c\A-- • - PHONE NO. 3. 'RESIDENCE INFORMATION: (circle year of dwelling, indicate#bedroom(s) and multiply Il.of bedrooms with applicable gallons per bedroom to equal total daily flow) Year of House: No. of Bedrooms x Computation = Total Daily Flow 1980 or older • x 150 gal/bdnn = 1980— 1991 x 130 gal/bdrtn = . 1991 —present x 110 gal/bdrm = Garbage Grinder Installed yes` / no Spa or Whirlpool Installed yes ; / no • 4. PARCEL INFORMATION: (circle applicable information &indicate measurements) • • 9uradt 119 Q.rQund_Watpr _Bed.roGk_primPer_vio s Domestic Water.SMPIY �hlat :rand at what depth at what depth nnththapal • lolling loam feet feet well Steep slope clay if well; water supply _%slope other from any septic-system . depth: absorption is ft. other Percolation Test: (To be completed by licensed professional engineer or archllect) Rate: minute per Inch 5. PROPOSED SYSTEM: For New Construction: All individual sewage disposal systems must be designed by n licensed professional engineer or architect(unless installed in a Planning Board approved subdivision). Add 250 gallons to the size of the septic lank and leach field for each Garbage Grinder, Spa or Whirlpool Tub. Septic Tank: /MO gallon (min. size 1,000 gal.) Tile Field: each trench ft. Total System Length: fl. Seepage Pit(s): number of size of each: fl. by Jl. Size of Stone to be used: 11 " / depth or thickness Bed System Size: x Alternative System: length and/or size 6, HOLDING TANK SYSTEM: (if required) Number of tanks: / Size of each: - gallons /TOTAL Capacity: gallons Note: Alarm System and associated electrical work must be inspected by a Town approved electrical inspection agency. • 7. SIGNATURE &INFORMATION FOR RESPONSIBLE PERSON(please read) For your protection, please note that pursuant to Section 136-29 of the Code of the Town of Quoensbury, any permit or approval granted which is based upon or is granted in reliance upon any material misrepresentation or failure to make a material fact or circumstance known by or on behalf of an applicant, shall be void. I have read the regulations with respect to this application and agree to abide by these and all requirements of the Town of Queensbury Sanitary Sewage Disposal Ordinance. Agaii/e,a/kir 7% /o f Signature of responsible person Date Ink G COMMERCIAL FINAL INSPECTION REPORT Building& Code Enforcement Date inspection request received: Office No. (518)761-8256 Dept. of Community Development Town of Queensbury Arrive\; , .ry ptn . • +art '_,Y ,1°j�� 742 ay Road •4. tor's Initial, Queensbury, NY 12804 NAME PR0,6 C bRTNA PERMIT# LOCATION e1„..)‘'{-AT1cc, cAn DATE 12— TYPE OF STRUCTURE N/A YES NO COMMENTS Chimney/'3"Vent/Direct Vent location / Plumbing Vent Roof Complete N.6 Exterior finish grade complete interior/exterior guardrails 42 in.pl. orm/ / Interior/exterior ballasters 4 in.spa ;Igplatf decks _ Vit Stair handrail 34 in.-38 in. • • Step risers 7 3/4 in. Main door 44 in. • J All others 36 in. / Lever handles Exits at grade or platform Canopy to cover req.exit doors Gas valve shut-off exposed&regulator(18 . above grade Floor bathroom watertight I / Other floors okay Hot wafer relief valve sN / Boiler/fu nac enclosure <250,000 BTU N/R 250.000 BTU to 1,000,000 BTU's(1 hour) >1,000,000 BTU's(2 hour) Gas furnace shut off within 301 or within line of ite Oil furnace shut off at entrance to furnace area Stockroom enclosure(1 hour),'/4 hour door Storage/receiving/shipping.room(2 hour), 1 '/z doo 1 `4 hour doors and closers ?4 hour corridor doors and closers 1 lie,- _ Firewalls/fire separation,2 hour,3 h ur complete Fire dampers,2 hour fire wall/separation or greater Fire door/shutters 1 1/2 hour,3 hour Ceiling fire stopping 3,000/5,000 sq.fl. Fan shutdown,smoke vents or fan Exit door/panic bars assembly hardware Elevators Elevator signage Handicapped bathroom grab bars/sinks/toilets Handicapped bath/parking lot signage Handicapped service counters 34 in.,checkout 36 in. Handicapped ramp/handrails continuous/12 in.beyond Active listening system and signage assembly space Final Electrical Site Plan/Variance required_ Final Survey,new structures As-built septic system layout required Okay to issue temp.CIO(Certif.of Occupancy) ttik)kay to issue permanent C/O(Certif.of Occupancy) 1'tizOkay to issue C/C(Certif.of Compliance) COMMERCIAL FINAL INSPECTION REPORT ____-A. 14/)----, ' Building& Code Enforcement Date inspection request received: Office No. (518)761-8256 Dept. of Community Development Town of Queensbury Arrive f r ain—De..' 742 Bay Road spector's Ini • Queensbu NY 12804 G r M NAE . A I� c)) N1 ()t, PERMIT LOCATION , Ccx_ 1 � o;�_ DAT — TYPE OF STRUC ' Co rn if 1j o PDD,, �: N/A YES NO COMMENTS Chimneyf'B"Vent/Direct Vent 1 an\ Plumbing Vent ��, ii Roof Complete \ \� Exterior finish grade complete / Interior/exterior guardrails 42 in.pl.' orm/dedcs -✓ Interior/exterior ballasters 4 in.spacin< platform/decks Stair handrail 34 in.-38 in. 1 Step risers 7 3/a in. 1/ Main door 44 in. 1 All others 36 in. I >f Lever handles \ (//. Exits at grade or platform Vii . Canopy to cover req.exit doors Gas valve shut-off exposed&regulat. N .)above grade V/j Floor bathroom watertight •,/ Other floors okay ` •✓ Hot water relief valve •,/ •t Boiler/furnace enclosure <250,000 BTU N/R 250.000 BTU to 1,000,000 BTU's(1 ho r) • >1,000,000 BTU's(2 hour) Gas furnace shut off within 30 ft or within lin of site Oil furnace shut off at entrance to furnace area • Stockroom enclosure(1 hour),3/6 hour door Storage/receiving/shipping room(2 hour), 1 '/A oors 1 '4 hour doors and closers '.hour corridor doors and closers t-*-4Q FR\ u +� g ,\�� � Firewalls/frre separation,2 hour,3 hour complet ti`3-v1`5 Fire dampers,u 2 hour fire 3 ouration or gr F 1 LS/ ������ Fire door/shutters 1 '/2 hour,3 hour Ceiling fire stopping 3,000/5,000 sq.fl. ti ,r� Fan shutdown,smoke vents or fan �_ �V �'�1-1� . lam'J� `� Exit door/panic bars assembly hardware Y `) Cl _ Elevators �=�i�� \ \, o Elevator signage l Handicapped bathroom grab bars/sinks/toilets Handicapped bath/parking lot signage ? ' - Handicapped service counters 34 in.,checkout 36 in. Handicapped ramp/handrails continuous/12 in.beyond Active listening system and signage assembly space ` Final Electrical ✓ Site Plan/Variance required_ Final Survey,new structures As-built septic system layout required Okay to issue temp.C/O(Certif.of Occupancy) / Okay to issue permanent C/O(Certif.of Occupancy) Okay to issue C/C(Certif.of Compliance) • 11/40 RESIDENTIAL FINAL INSPECTION REPORT Office No.(518)761-8256 Date inspection request received: Building&Code Enforcement 11 Dept.of Community Development Arrive i,/GJ am/pm Depart m/pm Town of Queensbury Inspector's Initials ( �' 742 Bay Road Queensbury,New York 12804 NAME �G`7 c �C�bC%131i_`-A— 1..,3,0WrirA PERMIT#27tCyl S)5 LOCATION "27-17 f�J t e'r\ DATE 0 % '- Z f 6 TYPE OF STRUCTURE C'N NI"-ic$ )V) N/A YES NO COMMENTS Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake Plumb Vent through roof Roof Complete Exterior Finish Complete Interior/Exterior Railings 30"to 36" Exterior Handrails,balconies,land'.`.: 18 in.or more Interior Handrails stairs both side- .r more risers Grade 2%away from foundation 8"clearance to sill plate Gas Valve shut-off exposed/re: :: .r 18"above grade Gas Furnace shut-off within 30 fe. or within line of site Oil Furnace shut-off at entrance t.furnace area Furnace/Hot Water Heater opera !n g Relief Valve(s)installed Headroom,6 ft.6 in.on stairs Gekv� AAJA, fe- Basement stairs,6 ft.4 in. l� Handrail exterior stairs bo sides I ore than 3 risers Interior privacy/trim/d s/main en' . ce 36" Floor Finish Bathroom/Kitchen watertight Interior Handrails Balconies/Landin.18 in.or more Railing across window in stairwells Smoke Detectors: every level every bedroom outside every bedroom inter connected Bathroom fans Plumbing fixtures Foundation insulation 3/a hour fire door/door closer Garage fireproofing Garage penetrations sealed Furnace in separate room protected(in garage) Light ventilation per room Safety glazing 18"or less from floor Final Electrical Site Plan/Variance required Final Survey Plot Plan As Built Septic System layout required Okay to issue C/C(Certif.of Compliance) Okay to issue temp.C/O(Certif.of Occupancy)_ Okay to issue permanent C/O(Certif.of Occupancy) COMMONWEALTH ELECTRICAL INSPECTION SERVICE,INC. Main Office 176 Doe Run Road-Manheim,PA 17545 MUNICIPAL CERTIFICATE - ELECTRICAL APPROVAL Permit No. Cert. N© 7 3 5 6 7 Cut-in Card No Owner P/vV J Per 'C1.1461-6 £ A O 2T44— A-u Location 1�, � Installation Consisting of.�� . G L�) gj..$Y2"�-"-'y er1 6-6 Z.,/ S:a 3-ee-J2• G/72-5) ei T 6T Installed By W i ' 1u Lam ' Lic.No. The conditions following governed the issuance of this certificate,and any certificate previously issued is cancelled:- This certificate only covers the electrical equipment and installation conditions as of date. Upon the introduction of additional equipment or alterations,application shall be promptly made for inspection. Inspectors of this Company shall have the privilege of makin inspections at any time, and if it: rules are violated, the Company shall have the right to eyeke thi e ificate. Date / 2 ` l / INSPECTOR iiii: COMMERCIAL FINAL INSPECTION REPORT Jo .66/4itl Building& Code Enforcement Date inspection request received: is _ // B i Office No. (518)761-8256 Dept. of Community Development _ Town of Qiaeensbury Arrive�b-to an n Depart N 742 .;,ay Road Inspector's Initi Queeets /33Ay bu 12804 NAME Iee5 #„_____a,v-e_ PERMIT# - (` S . LOCATION Ap j DATE I a /17L/O/ TYPE OF STRUCTURE _.?)h. •( .Ac .4r2-.. N/A YES NO CO S Chimney/'3"Vent/Direct Vent location Plumbing Vent Roof Complete Exterior finish e Interior/exterior guardrai sl compi42 V in. atform/decks 0::itA7`i-��C `3,1 c.36 Interior/exterior ballasters 4 in spa g platform/dedcs Stair handrail 34 in.-38 in. Step risers 7 3/4 in. Main door 44 in. All others 36 in. ./ Lever handles / 1/ 1 e e.>-VOttl.- QeoFe_ Vik;k 7 1%( Exits at grade or platform . / . Canopy to cover req.exit doors �� Gas valve shut-off exposed&r.4 ator(18 in.)above grade J Floor bathroom watertight Other floors okay Hot water relief valve Boiler/furnace enclosure <250,000 BTU N/R 250,000 BTU to 1,000,000 BTU's 1 hour) , >1,000,000 BTU's(2 hour) Gas furnace shut off within 30 ft.or with-' line of site Oil furnace shut off at entrance to furnace: ea Stockroom enclosure(1 hour),3/4 hour d i Storage/receiving/shipping room(2 hour), 'A doors 1 "i hour doors and closers 4 hour corridor doors and closers id' //7PF-Cc.--A• ��J sv^VV\ 1;\ �� Firewalls/fire separation,2 hour,3 hour co ,,lete • Fire dampers,2 hour fire wall/separation of greater j-"T-v - t . cYL Fire door/shutters 1 '/2 hour,3 hour Ceiling fire stopping 3,000/5,000 sq.ft. � Fan shutdown,smoke vents or fan r 1 -C-C- v keic.-1c ci Avk ,` Exit door/panic bars assembly hardware v Elevators Elevator signage Handicapped bathroom grab bars/sinks/toilets 1( {�' .2) ---- e,l `Handicapped bath/parking lot signage C- ` �� \•• � Handicapped service counters 34 in.,checkout 36 in. Handicapped ramp/handrails continuous/12 in.beyond Active listening system and signage assembly space Final Electrical Site Plan/Variance required_ Final Survey,new structures As-built septic system layout required Okay to issue temp.C/O(Certif.of Occupancy) Okay to issue pa nanent C/O(Certif.of Occupancy) Okay to issue C/C(Certif.of Compliance) I Art" Town of Queensbury �, Fire Marshal's Office 742 Bay Road Queensbury, NY 12804 Phone (518) 761-8205 Fax(518) 745-4437 1 Fire Marshal's Inspection Report Request ii G Received: 1 �_ ( Permit# — 5- I INSPECTION ON: rZ'�I �® Name: 1Q5 A- L.DC,k19 I Nor Li-- I OOO p PM ANYTIME Location:_1_3.____Rv 1ri-loin pcj n1 ( ) APPROVED N/A YES NO COMMENTS EX AISLE WIDTHS J 1 w p1 eed .0 l-i inu.15 v , EXIT SIGNS-NORMAL X (t\ 1►1 r r ,e--to4 - BATTERY 'air EMERGENCY LIGHTING 3< Z� �� t �� ;, fir. �CL'i� FIRE EXTINGUISHERS X FIRE ALARM SYSTEM X PCr ,0°1 * FIRE SPRINKLER SYSTEM 1 - l FIRE SUPPRESSION SYST 3) CO 111 e --;f� c k - -T i ij 0 HOOD INSTALLATION i 1 doINTERIOR FINISHES ii) Aced 't'0 - P*4' -WnG ��t,1` w i STORAGE Will \\ COMPRESSED GA 3e" JJ Wilt Merl to e, ci 'i anA CLEARANCE TO SP- ` LE•S CLEARANCE TO HEATING . t fdr G 1.e. UNITS X (� ] CLEARANCE TO ELECTRIC A L E) -{'1 M.\ IC l.� 6c, REQUIRED SIGNAGE ,it" Ca I' ,1 i�. EMERGENCY PLAN SC '7) C'UpG�+n� ;;I1 fo p-�r MAXIMUM OCCUPANCY SIG . )C ,�_` ,, CHIMNEY _ irti 4l 4L MASONRY ROUG IN FINAL CHIMNEY FACTORY BUILT ROUGH IN FINAL WOOD STOVE ROUGH IN FINAL VENTED GAS APPLIANCE ROUGH IN _ FINAL FIREPLACE - MASONRY ROUGH IN OK7AclokCF®R CO NOT OK FINAL k FIREPLACE `° \ � �Y FACTORY BUILT ROUGH IN ���� IN "`�_T BY FINAL COMDEV/CHRISJ/WORDILETTERS2001/FIREMARS HALI NS PECTIONREPORT19022001 WHITE-BUILDING DEPARTMENT COPY YELLOW-OCCUPANT COPY 1 /o/% • GENERAL INSPECTION REPORT ( 518 ) 761-8256 Town of Queensbury Dept.of Community Development Date inspection request received: /0/S-A7/ Building& Code Enforcement 742 Bay Road Queensbury,NY 12804 Arrive . 403 Depart , m spector's Initial NAME: P� ��, t / PERMIT# LOCATION:_ _! DATE : /6 TYPE OF STRUCTURE: RECHECK N/A YES NO COMMENTS Footings/Piers I- I Monolithic Pour Form Reinforcement in Place The contractor is responsible 'or providing protection from fre:zi g for 48 hours following the pla,-ment of the concrete. Materials for this purpose o ite Foundation/Wallpour Reinforcement in = ace Foundation/Dampproofing Backfill Approval Plumbing Under Slab Plumbing Vent/Vents in Place Rough Plumbing Heating Rough-In Insulation ` Q,(4.0 ✓ Foundation Walls Interior R- Foundation Walls Exterior R-L Floors R- v / \ \ Walls R- i�t / Lf:dil L \ 14/7 0 L �,`1^ GN Ceiling R- �-�-- Duct work or piping in ^� E ,�tJ 4�1.L l ii unheated spaces R- Proper Vent, Attic Vent 173 106z, Framing Jack Studs/Headers Bracing/Bridging Joist Hangers Jack Posts/Main Beam_ Air Infiltration Barrier Fire Separation 1,2, 3,hour Penetration Sealed Fire Wall 2, 3,4 hour Firestopping GENERAL INSPECTION REPORT ( 518 ) 761-8256 Town of Queensbury Dept.of Community Development Date inspection request received: Building&Code Enforcement 742 Bay Road Queensbury,NY 12804 Arrive '2' Depart'', <_.t� spector's Ini ads " ~ NAME: Pei)c c6 C} d PERMIT# LOCATION: eiN �"T!i cis rt() DATE : TYPE OF STRUCTURE: C Q i`1t•-•‘CRC VA L- A C • RECHECK N/A YES-NO COMMENTS Footings/Piers Monolithic Pour Form Reinforcement in Place The contractor is respo • ble fo providing protection fro freezin;. for 48 hours following the placem:i t of the concrete. Materials for this purpose on site Foundation!Wallpour Reinforcement in Place Foundation/Dampproofing Backfill Approval Plumbing Undcr-Slab. Plumbing Vent/Vents in Place Rough Plumbing Heating Rough-In S Insulation Ec.NE_c, Foundation Walls Interior "- Foundation Walls Exterior '•- Floors R- .Walls R- Ceiling R- Duct work or piping in unheated spaces R- Proper Vent,Attic Vent Framing Jack Studs/Headers Bracing/Bridging Joist Hangers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1,2,3,hour Penetration Sealed Fire Wall 2, 3,4 hour Firestopping C ha' GENERAL INSPECTION REPORT ( 518 ) 761-8256 Town of Queensbury Dept. of Community Development Date inspection request received: Building& Code Enforcement 742 Bay Road Queensbury,NY 12804 Arriwagn Depart -D . , •�Allo -\ or's Initia's ,_. NAME: C C I PERMIT# . -S LOCATION:(11)\(0 _,P 1;p` L�J DATE : / TYPE OF STRUCTURE: o PiT N ,5\S=W flM1T\Dtv_ RECHECK N/A YES NO COMMENTS Footings/Piers I F Monolithic Pour Form Reinforcement in Place n, The contractor is respo ible or providing protection fr freg for 48 hours following th` place ent of the concrete. Materials for this purpose on site Foundation/Wallpour Reinforcement in Place Foundation/Dampproofing Backfill Approval Plumbing Under Slab Plumbing Vent/Vei is in.Place Rough Plumbing Heating Rough-In Insulation Foundation Walls Interior R- Foundation Walls Exterior R- Floors R- Walls R- Ceiling R- Duct work or piping in u eated spaces R- •r Pro Ve' Attic Vent / raming N �`l . •- V., O O 16,l) rc Jack Stu. /Headers ✓ 1�� � Bracing/Bridging 3, Joist Hangers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1,2,3,hour Penetration Sealed Fire Wall 2, 3,4 hour Firestopping Al. athi1has ' GENERAL INSPECTION REPORT L-�- ( 518 ) 761-8256 Town of Queensbury ' Dept.of Community Development Date inspection request received: ? a(jj I Building&Code Enforcement 742 Bay Road Queensbury,NY 12804 Arrive VA5—amepart " im Inspector's Inn ' NAME: yS�g�G ( IIJ PERMIT# —S/5 LOCATI : j 3 3 A,'aD( et DATE: TYPE OF STRUCTURE: —71/Dn/-4 — RECHECK ' - Ai) N/A YES NO COMMENTS Footings/Piers Monolithic Pour Form Reinforcement in Place The contractor is responsible for providing protection frori fre ing for 48 hours following te pla ent of the concrete. Materials for this purpose o A site Foundation/Wallpour Reinforcement in Place Foundation/Dampproofing Backfill Approval Plumbing Under Slab Plumbing Vent/Vents in Pl.r- Heating Rout -In Insulation Foundation Walls Interior R- Foundation Walls Exterior R- Floors R- Walls R- Ceiling R- Duct work or piping in unheated spaces R- Proper Vent,Attic Vent 7 Framing Jack Studs/Headers Bracing/Bridging Joist Hangers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1,2,3,hour Penetration Sealed Fire Wall 2,3,4 hour Firestopping I Pin GENERAL INSPECTION REPORT ( 518 ) 761-8256 Town of Queensbury Dept.of Community Development Date inspection request received: Building& Code Enforcement 742 Bay Road Queensbury,NY 12804 Arrive- Dep ►' mom-' In•i'.•ctor's i i.':i• �• NAME: 1 0"Ak PERMIT# b/ 5`S LOCATION: c,. ci U.^ DATE: - TYPE OF STRUCTL`RE: RECHECK N/A YES NO COMMENTS Footings/Piers 1 Mon ethic Pour Form rcement in ' a The contractor is re .•nsible for providing pro ection from freezing for 48 hours following the placement of the concret:. Materials for this .urpose on ite Foundation/Wall..ur VA; /� Reinforcement in " ace t/ Foundation/Dampp .ofing _ - Backfill Approval Plumbing Linder Sla• Plumbing Ven e i :in Place Rough Plumbing - Heating Rough-In Insulation Foundation Walls In crior R- Foundation Walls Ext•,rior R- Floors R Walls R- Ceiling - Duct work or piping in unheated spaces "- Proper Vent,Attic Vent Framing - Jack Studs/Headers Bracing/Bridging Joist Hangers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1,2,3,hour Penetration Sealed Fire Wall 2,3,4 hour • Firestopping GENERAL INSPECTION REPORT ( 518 ) 761-8256 Town of Queensbury Dept.of Community Development Date inspection request received: LS v/ Building&Code Enforcement 742 Bay Road il Queensbury,NY 12804 Arrive 4.._ •y► Depart P � Inspector's Ini 'NAME: G� Ov PERMIT# /-57-5 LOCATION: . Ar-re S41,, DATE: ,AI/ a�/ TYPE OF STRUC J RECHECK / ' ;# '4__T - - k .7( —- ::-.,4,,,- i ,,,- 32 ,_. 3 .:., N/A YES 4 O COMMENTS Footings/Piers l ~----1, I Monolithic Pour F n Reinforcement h. lac The contracto is responsible for providing pro ction from freezing for 48 hours '.11owing khe placement of the concret-. Ma :1. or thi• purpose on site ::!tion/Wa�;y: '/ Reinforcement in Foundation/Damp, ,fing Backfill Approva Plumbing Under Sla• Plumbing Vent/Ven in Place Rough Plumbing Heating Rough-In Insulation Foundation Walls In erior R- Foundation Walls E erior R- Floors R- ° Walls R- Ceiling R- Duct work or piping i unheated spaces \R- Proper Vent,Attic Vent Framing Jack Studs/Headers Bracing/Bridging Joist Hangers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1,2,3,hour Penetration Sealed Fire Wall 2,3,4 hour Firestopping Y- GENERAL INSPECTION REPORT ise,,,,/, - ( 518 ) 761-8256 Town of Queensbury Dept.of Community Development Date inspection request received: 4 Building& Code Enforcement 742 Bay][toad r `, Queensbury,NY 12804 Arriv� m Depart 1 am/. 4117 spector's Initi. : - r. L -.) &,,c,\c,,,,L_N6acipRmiT#1,NAME: �(��LOCATION: /3 3 }lL`, Lk. (KC DATE: — - CO/ TYPE OF STRUCTURE: (y)<-), t RECHECK N/A YES-NO COMMENTS Footings/Piers I Monolithic Pour Form Reinforcement in Place The contractor is respons' le or providing protection fro free 'ng for 48 hours following t e place ent of the concrete. Materials for this purpose on site Foundation/Wallpour Reinforcement in Place Founda►'on/Damppro g �_Mom:.:__:,:;6:_a \_\ - Plumbing Under Slab Pl bing VentNents ' lace Roi g lumb. g / Heating Rough-In Insulation Z.-" 11w'j \Fou non Walls Inte 'or R- t ��Edfindation Walls Ext 'or R- Floors / R- Walls ? R- Ceiling R- Duct work or piping in unheated spaces R- Proper Vent,Attic Vent Framing Jack Studs/Headers Bracing/Bridging Joist Hangers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1,2,3,hour Penetration Sealed Fire Wall 2,3,4 hour Firestopping 06-P.4-01 11 :SS RICHARD E. JOINS ASSOC. ID=5167932223 P.01 Richard (. Jones Associates Architects-Environmental Planners 339 Aviation Road Queensbury,NY 12804 Telephone(518)793-1015 Fax(518)793-2223 e-mail:rejrany@capital.net Fax Memo To: Dave Hatln,Town of Queensbury(Fax:745-4437) From: Richard Jones Date: 8/9/01 Re: Prospect Child& Family Center Dove: In order to facilitate construction,the General Contractor V &H Construction requested us to change the thickness of our foundation walls from 8" wide to 10" wide. We reviewed the request and approve it. This change will affect the drawings F-1 details 1/F-1 and 2/F-1 dated 5-24-01, entitled foundation plan and details already submitted to your office. Thank you. If you have any questions,please contact me. Sincerely, Jorge Correa Cc: V&H Construction(Rob Holbrook) E:11998198271Regulatory Agency FilelFax Memo 010809.doc ot-, ,\41,1 2__ \\. 1•, ). .,cc-, ,,, ,, .__,,,,,,,,„„.„-„,„,„;,,...„ GENERAL INSPECTION REPORT 'c)' � ( 518 ) 761-8256 Town of Queensbury ' Dept.of Community Development Date inspection request received: `-� Building& Code Enforcement 742 Bay Road Queensbury,NY 12804 Arrive r m Depart % i Alli fy.m y Inspector's Initial. NAME: ( Cr- Th PERMIT#_i 0. )- S LS LOCATION: \ 3 c o tc ) DATE: •--.1--At. TYPE OF STRUCTURE: RECHECK A N/A YES/NO COMMENTS otengs/Piers ,dj-rog ACT_ 43 AN.( VI l onolithic Pour Form ` ' G. ✓ enforcement in Place rt ,i k' 1,R ot5 of The contractor is responsible.'or le:FT I J providing protection from ` g for 48 hours following the p'. -ment of the concrete. Mate 'als for this purpose o 4 to dateon/Wallpour `" 11.c'nR., v// _ Reinforcement in Place r/ Foundation/Damppro• ng Backfill Approy,al' Plumbing Under Slab Plumbing Vent/Vents in Plac Rough Plumbing Heating Rough-In Insulation Foundation Walls Interior R- Foundation Walls Exterior - Floors R- Walls R- Ceiling R- Duct work or piping in unheated spaces R- Proper Vent,Attic Vent Framing Jack Studs/Headers Bracing/Bridging Joist Hangers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1,2,3,hour Penetration Sealed Fire Wall 2,3,4 hour , Firestopping . GENERAL INSPECTION REPORT ( 518 ) 761-8256 Town of Queensbury ) Dept.of Community Development Date inspection request received: 5V /D Building& Code Enforcement 742 Bay Road Queensbury,NY 12804 Arrive 3 Depart °le .m/ Nor ���E( 5;l`' spector's hi '. f ff NAME: 3 ro. ' '1 GA `�1 f^(air c�4' +PERMIT# - * (— 75 LOCATION: ", J,q- -i C (U>- DATE: i ()/ a,— TYPE OF STRUC : l l J RECHECK N/A YE�NO COMMENTS Footings/Piers �, I Monolithic Pour Form Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the p .•;ment of the concrete. Materials for this purpose o Foundation/Wallpour Reinforcement in Place Foundation/Dampproofing Backfill Approval Plumbing Under Slab Plumbing Vent/Vents in PI- Rough Plumbing Heating Rough-In Insulation Foundation nterio R- Foundation Walls Exterio t R • - Floors R Walls R- Ceiling R- Duct work or piping in unheated spaces R- Proper Vent,Attic Vent Framing Jack Studs/Headers Bracing/Bridging Joist Hangers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1,2,3,hour Penetration Sealed Fire Wall 2,3,4 hour Firestopping 0 NOTE I REMOVE METAL STORAGE 81 . NiCLWNIG POUNDATION 1 SLAB. EXTERM L"T I POOR SIMPLY. RELOCATE AS INDICATED 04 SP-2 NOTE 2 REMOVE / DISPOSE OP SMUG SET. NOTE 8 REMOVE 1 DISPOSE OP SHED 11M. NOTE 4 REMOVE !PENCE t GATE. TEMPORARILY RELOCATE FENCE 1 GATE AS INDICATED ON T145 DWG.. FINAL LOCATION AS INDICATED dt SP-2. NOTE 6 REMOVE ASPHALT TALK 1 BASE MATERIAL. NOTE I REMOVE SEPTIC SYSTEM IN ITS ENTIRETY. SALVAGE SEPTIC TANK POR RELOCATION AS INDICATED ON SP-2 NOTE 1 REMOVE DRYIELL AND PORTION OF PIPE AS INOCATED. SALVAGE DRYWELL FOR RELOCATION AS INDICATED ON SP-2.. NOTE I PREPARE AREA TO RECEIVE NEW ASPHALT PAVING INCLUDING CLEARING OF TREES. STUMPS. ROOTS t GMBING. NOTE 1 REMOVE SECTION OF EMT. FENCE t GATE FOR CONTRACTOR ACCESS TO SITE WORK AREA. PROVIDE TEMPORARY GATE ACCESS TO SECURE WORK AREA. REINSTALL ORIGINAL GATE t PENCE AT COMPLETION OF PROJECT t RESTORE ALL WALK SURFACES 1 LAWN AREAS. Application R 5 1 ZOnina Administrator 'qj: , Z'.; W� Z Z Wk' V � ,. x�. t 00 R� -a cq �- o a on L5 y ,£ .,,.4 ui w Y C3 }„ w o W LL. z m cc U �- 0 o_ < V t- z > W Ifl0U MONO 93 4 tY�a c» a-._' 'Q to ...IN 4 C 0) O PCs A= 0 W� ui 0% t . I n co h U co Qom/ ... � -.. - \ A` R U UZn 0 N3 SANITARY DRAINAGE CONNECTION SP-2 1/2• - 1'-0' 3' SHREDDED BARK MULCH 3' HIGH SAUCER AMENDED PLANTING I SOIL SHRUB PLANTING DETAIL yr DRYWELL DETAIL SP-2 1/2• - 1'-0• FRAME I GRATE. T.O.P. ELEV. EPAGE PIT. 7-0' COVER MIN. PRECAST CONC. EXTENSION TO GRADE r CONC. COVER 82 CRUSHED STONE: 8' O.D. PRECAST CONC. DRYWELL -V PVC EQUALIZER PIPE • 7-0 ABOVE BOTTOM. GEOTEXTILE FABRIC. FOUNDATION RING. PROVIDE HIGH DENSITY POLYETHYLENE PIPE SEALS AT ALL PIPE CONECTIONS. OUTLET TEE -- ;[& MIN. 1/I6' PER FT l: PRECAST REINP. CON I.000 GAL. SEPTIC T, J n t' D. C"ACTED PEA a NEW 7-0 • FRAME AND COVER ACCESS. W/ PRECAST GRADE EXTENSIONS. NEW 7-0 • TAPERED HOLE t PLUG `• •PVC TYP. 2 PLACES.---n MOPE MIN. VA' PER FT. 5'-0' LIQUID L a RELOCATED SEPTIC TANK DETAIL ( 1000 GAL. ) SP-2 yr - r-o• SITE LEGEND CRP O - CAPPED IRON ROD POUND EXISTING BUE.OING IPP O - IRON PIPE POUND RP O - IRON ROD POUND NEW BUILDING CB ❑ - CATCH BASIN TEL t] - TELEPHONE PEDISTAL NEVI ASPHALT PAVING Illt!'NR TO DETAIN. i/SP-2. D4 HATER VALVE ? - HYDRANT 'llult" Or BUINDING REFER TO VOIDV -EDIT -�- - SIGN - TREES - EXIST. LIGHT POLE - UTILITY POLE T.O.P. TOP OF FRAME — O - EXIST. CHANT LINK PENCE f ETR) EXISTING TO REMAIN - EXIST. WOOD PENCE PROPERTY LINE X - EXIST. WOOD t WE PENCE i i i i i i i• STORM DRAIN E UNDERGROUND ELECTRICAL I UNDERGROUND WATER LINE G UNDERGROUND GAS LINE 102.li MEW SPOT ELEVATION i00 NEW CONTOUR ----------- 45----- EXISTING CONTOUR GENERAL NOTES: ALL SITE INFORMATION OBTAINED PROM SURVEY PREPARED BY VAN DUSEN I STEVE$. LAND SURVEYORS, LLC. 31 CHESTER STREET, GLENS FALLS. NEW YOM a" (NY LIC s50316). SURVEY DATED FEBRUARY 1[. 2000. THE CONTRACTOR SHALL STAKE OUT ALL LOCATIONS PRIOR TO COMMENCING CONSTRUCTION. ANY DISCREPANCIES SHALL IMMEDIATELY BE BROUGHT TO THE ATTENTION OF THE ARCHITECT BEFORE PROCEEDING WITH THE WORK. LOCATE ALL EXISTING UNDERGROUND UTILITIES PRIOR TO EXCAVATION WORK. EACH CONTRACTOR SHALL PROTECT ALL EXISTING TREES t SRE IMPROVEMENTS THAT ARE NOT DESIGNATED TO BE REMOVED. BENCH MARK ELEVATION OF vur IS TAKEN FROM THE NO NUT ON HYDRANT LOCATED AT THE CORNER OF MOUNTAINVINW LANE t AVIATION ROAD. REPER TO SP-1 FOR SITE WORK REMOVAL. LANDSCAPE AND EROSION CONTROL NOTES: ALL ALAS DISTURBEDBYDEVELOPMENT SHALL BE RECOVERED WITH MINIMUM HEAL HT S TA! 0 OF GRAbS� EAST AND AND A�F,UNTIL AD. ALL PLANTS SHALL BE NURSERY GROWN AND SHALL BE DELIVERED FREE FROM INJURY. INSECT D II'ESTATION AND DISEASE PLANT SIZE AND GRADING STAND SHALL CONFORM TO THE LA T EDITION OF 'AMERICAN STANDARD FOR STOCK' SPONSORED BY THE AMMAN ASSOCIATION OF NURSERYMEN. INC. EROSION CONTROL MEASURES IN CONFORMANCE WITH THE UDA GUIDELINES FOR URBAN THROUGNIOUT CONSTRUCTION ANDOM AND �IMCONTROL ADEQUALT ESTANDMAINTAINED OOFF DAIS IS ESTABLISHED. LIGHTING SCHEDULE ( NEW t msTING). -NEW SOFFIT LIGHT: 50 WATT ( REFER TO DWG. E-2 ). -EXIST. SOFFIT LIGHT: 10 WATT HPS. -EXIST. WALL LIGHT: 100 WATT HIPS. MAIN CENTER PARKING: EXISTING 22 (INCLUDING 3 HC) PROPOSED 1 i' TOTAL PROVIDED 1 CLASSROOMS X 4 EACH 28 2140 SP (ADO)/ 60 SF 18 VISITORS 5 51 REQUIRED PROSPECT SCHOOL AND ADMINISTRATION BUILDING PARKING: EXISTING (SCHOOL) 102 + (ADMIN) 23 (INCLUDING 5 HC) PROPOSED 39 144 TOTAL REQUIRED 9 CLASSROOMS X 4 EACH 31 ADMINISTRATIVE BUILDING 2212 SF/150 SF 15 IOS35 (2 STORY ADD.)/150 SP 10 VISITORS 21 142 REQUIRED PARKING ENTIRE CAMPUS: REQUIRED - PROVIDED = TOPSOIL t SEED COMPACTED FILL li:1•:F1 . ._. PIPE SIZE AS 1REQ'D. REFER TO SITE PLAN. PIPE BEDDING MATERIAL SAND OR FINE GRAVEL 4 TYPICAL PIPE BEDDING SP-Z 1/2' - 1'-0' EXISTING PAVEMENT SAWCUT It REMOVE SECTION OF EXISTING PAVING AS REQ'D TO FEATHER NEW TOP COURSE INTO EXISTING PAVING. 11 PAVEMENT BLEND DETAIL SP-2 I. . r-O' NTSDOT TYPE L) 2 1/2' BINDER COURSE (NYSDOT TYPE 3) 10' COMPACTED BASE COURSE (NYSDOT TYPE 4) 193 TOTAL 143 TOTAL U 2 V2' BINDER COURSE (NYSDOT TYPE 3) NO• COMPACTED BASE COURSE (NYSDOT TYPE 4) 5 NEW ASHPALT PAVING DETAIL SP'2 I• - i'-o• TNK Rom. cw- SLAB VLx�-l�Wxl*or. %44 16 CONT. CONC. SLAB t HAUNCH FTG. SP-2 r - r-o'