Loading...
2002-844 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building&Codes (518)761-8256 CURTIFICATE OF COMPLIANCE Permit Number: P20020$4.4 Date Issued: Thursday, February 06,206 This is to certify that work requested to be done as shown by Permit Number P20020844 has been completed. Tax Map Number: 523400-239-017-0001-005-000-0000 Location: 15 ANTIGUA Rd Owner: HOWARD&JENNIFER NADLER Applicant: HOWARD&JENNIFER NADLER This structure may be occupied as a: By Otder of Town Board Garage-2 Cars Detached (7y EENSB kl-- Nector of Building&Code Enforcement w N TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 tilt Community Development- Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20020844 Application Number- A20020844 Tax Map No: 523400-239-017-0001-005-000-0000 Permission is hereby granted to: 140WARD &JENNIFERWADT.FR For property located at: 15 ANTIGUA Rd in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: HOWARD &JENNIFER NADLER Garage-2 Cars Detached 35,000-00 15 ANTIGUA Rd Total Value 35,000.00 QUEENSBURY,NY 12804-0000 Contractor or Builder's Name/Address Electrical Inspection Agency Plans &Specifications BP 2002-844 Construction of a 2 car detached garage(728 sq. ft) as per plot plan and specifications. Also, see BP 2001-581 for Single Family Dwelling permit. Applicant wants to begin construction on the garage first, therefore,this permit BP 2002-844 is separate from the single family dwelling permit. $0.00 PERMIT FEE PAID- THIS PERMIT EXPIRES: Wednesday, October 08,2003 (If a longerperiod is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town of Queensbury; Tuesday,October 08,2002 SIGNED BY for the Town of Queensbury. Director of Building&Code Enforcement BVEDEC Building Permit Application FZ Town of Queensbury-Dept of Community Development,742 Day Road, Queensbury,NY (518)761-8256 - - OCT 0 ?. 2002 QUEE14SBURY A perinii.must be obtained before beginning construction. Permit File NO A�0 CODE No insp�`ttion will be made until applicant has received a 1�11 Fee Paid valid building permit. All applicants' spaces on this Rec. Fee Paid application must be completed and must appear on the- Reviewed By: application form. Applicant: .�Aoac� , Owner: Address: NS P'N"t4l'- Address: Phone,#(-5) ) WS --R I WO Ph-one# Email Address: A4Nc�kk P MONO-1,6— Email Address: Property'Location; Lot Number: House Number Subdivision Name; Tax Map Number: New Buildir� -:�=.idenli. himercial Estimated Market Value of Construction- $ 3 Sago Me r ..i . c3 A44ition: rest en../ commercial If an Addition,what will use of new addition be? o Alferation: residence/ commercial U No change to exterior size: residence I com'l C3 Other work(describe Check OccupancyInformation 1"Floor 2° Floor Other floor Total Below sq.ft. sq.ft. sq.ft. Square Feet U Single family dwelling 0 Two family dwelling U -Townhouse Multifamily dwelling #of units 0 Office u -Mercantile U Manufacturing" L3 /I car detached garage §;( 2 car detached garage o 3 car detached garage -:0 1 car attached garage o 2 car attached garage 3 car attached garage Storage building- commercial '0 Storage building- residential 0 -Other �_What is the proposed heig t of the structure feet inches Will any second-hand or ungraded lumber be used? If so,forWhat? Type of Heating System: electric/ oil gas t wood /forced hot air baseboard othet: Number of ALrjeqlaces to be installed Number of Woodsfoves to be installed List below the person(s)responsible for supervision of work as regards to building codes: Name Address Phone Number Builder Plumb6i.-." nb Electrician Declaration:`please sign below after you have carefully read the statement: To the best of my knowledge the statements contained in this application,together with the plans and specifications submitted,are a true and complete statement of all proposed work to be done on the described premises and that all provisions of the Building Code,the Zoning Ordinance and all other laws pertaining to the proposed work shall be complied with,whether specified or noted,and that such work is authorized by the owner. Further,it is,understood that I/we shall submit,prior.,to a Certificate of Occupancy or Certificate of Compliance being issued,as requested by the Zoning Administratoi or Dire or of Building and Codes,an As Built Survev by a licensed surveyor;drawn to scale,showing actual location ofall new o tru/'on. Signature owner,owner's agent,architect,contractor RESIDENTIAL FINAL INSPECTION REPORT Office No.(518)761-8256 Date inspection request received: Building&Code Enforcement Dept.of Community Development Arrive am/pm Depa rtl�- Town of Queensbury Inspector's Initials 742 Bay Road Queensbury,New York'12804 r r NAME PER.NII'f c � , LOCATION DATE `�I — TYPE OF STR.UC ' NIA YES NO COMMENTS ' Chimney Height/"B"VentlDirect Vent Location _ Fresh Air Intake t, Plumb Vent through roof Roof Complete T Exterior Finish Complete Intedor/Extedor Railings 30"to 36" Exterior Handrails,balconies,landing 18 in.or more Interior Handrails stairs both sides 3 or more risers Grade 2%away from foundation , 8"clearance to sill plate Gas Valve shut-off exposed/regulator 18"above grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Relief Valve(s)installed headroom,6 ft.6 in.on stairs Basement stairs,6 ft.4 in. Handrail exterior stairs both sides more than 3 risers Interior privacy/t im/doors/main entrance 36" Floor Finish Bathroom/Kitchen watertight Interior Handrails Balconies/Landing 18 in.or more Railing across window in stairwells Smoke Detectors: every level every bedroom outside every bedroom inter connected Bathroom fans Plumbing fixtures Foundation insulation 3/a hour fire door/door closer Garage fireproofing Garage penetrations sealed Furnace in separate room protected(in garage) Light ventilation per room Safety glazing 18"or less from floor Final Electrical Site P1anlVariance required Final Survey Plot Plan As Built Septic System layout required Okay to issue C/C(Certif.of Compliance) Okay to issue temp.C/O(Certif.of Occupancy)__ Okay to issue permanent C/O(Certif.of Occupancy) RESIDENTIAL FINAL INSPECTION REPORT Office No.(518)761-8256 Date inspection request received: Building&Code Enforcement ` Dept.of Community Development Arrive am/pm Depart 1 I n/pm �> Town of Queensbury Inspector's Initials 742 Bay Road + Queensbury,New York 12804 NAME PERMIT# LOCATION r, DATE — TYPE OF STRUCTURE N/A YES NO COMMENTS Chimney HeightPT"Vent/Direct Vent Location Fresh Air Intakev Plumb Vent through roof Y Roof Complete Exterior Finish Complete : — Interior/Exterior Railings 30"to 36" Y Exterior Handrails,balconies,landing 18 in.or more Interior Handrails stairs both sides 3 or more risers ' Grade 2%away from foundation 8"clearance to sill plate Gas Valve shut-off exposed/regulator 18"above grade Gas Furnace shut-off within 30 feet or within line of site l Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating (l Relief Valve(s)installed Headroom,6 ft.6 in.on stairs Basement stairs,6 ft.4 in. Handrail exterior stairs both sides more than 3 risers Interior privacy/trim/doors/main entrance 36" Floor Finish Bathroom/Kitchen watertight Interior Handrails Balconies/Landing 18 in.or more Railing across window in stairwells Smoke Detectors: every level every bedroom outside every bedroom inter connected Bathroom fans Plumbing fixtures Foundation insulation 3/4 hour fire door/door closer Garage fireproofing Garage penetrations sealed Furnace in separate room protected(in garage) Light ventilation per room Safety glazing 18"or less from floor Final Electrical Site Plan/Variance required Final Survey Plot Plan As Built Septic System layout required Okay to issue C/C(Certif.of Compliance) Okay to issue temp.C/O(Certif.of Occupancy)__, Okay to issue permanent C/O(Certif.of Occupancy) 1"I COMMONWEALTH ELECTRICAL INSPECTION SERVICE, INC t Nam Office 176 Igoe Run Road ofManheim, PA 17545 00 MUNICIPAL CERTIFICATE • ELECTRICAL APPROVAL Permit No. NO Cut-in Card No,„pi„iff4f lMii YtHfifpp►pi#!M# i iYP Owner,,,,,,,,,M,, iltt!!!t!N!i tttiMNitDHi_4ftlff#pltplliitti!ltiitlf!!ii#!}t}i}p#ififlq/pii!/liiiN!!tlpttiNtttlN,f}#pfi}i}}}}}}i}},pffliiittit !tl!lti,llil f V Ow h R41 Locationip iif Nltt!!tt !!i!tlttil,l+lf}},t,if„ffp/ff!lipflpN!ltipiit!!ttlf,Nfiiflp,f,liNlplpfifi!liii!!liltit# i}lil,pilHpt!!i ,lifN/!iilt!littlt+ i M� � 4 ��1R ■ Installation Consisting of if t#t##fii iiffifiiH►f ti►if iHi! iitii}flfiffii ffflfifif/f##Nt NfJtlififf/1f/ifit+itfip iNffif# •ifiii/tip#Hf Mif/f iffi }},piffi ipNf ff#f,/ffffitli#}plfifif fpiftiff ppff it,f,#ff pf fi/i+N+it+lilp#lit tlflfllf,iplpipippitpff i„pf►ff if,iffp##lipip/pf►pp/f//lii N,f,pfipf/f fppf!! plfFlil+i►Mi//iipppi/f#p#p►t!f#ifi►f,lNiili} ,!/}Iipfppffi,ppff f,liNN#fillli!/#fN#Nffi#+lpplif}i,ilflifip#iflfff,fif#pf►+►ifif Nfifff+#f,!lifpii,!#if#/iif/f/i Installed By,,,,,,,,,fi# f #fipfff ifffff,if►fpllY,Yilp#ii#pfii,pfifffi,ffpfppfpfiippfff##Lie. No. iifiip/plfi/IltffHpi,}p,Nifffifp/Nlt,lfi The conditions following governed the issuance of this certificate, and any certificate previously issued i cancelled: This certificate only covers the electrical equipment and installation conditions as of date, Upon th+ introduction of additional equipment or alterations, application shah be promptly made for inspection. Inspectors of this Company shall have the privilege of maki ' pect'ons at any time, and if it rules are violated, the Company shall have the right to r ke t ' ce ` icate, Date }+!il,i,f„i,Nf#ffpfH,lfi#f!#fiif Niif,!►lii+ Ii SPECT�/ f,► pfpiH 4 fp►pffii►pii,ip„iit tii i,iffp E ti,llf,uuip,pffftfffititi Residential Final Inspection Office No.(518)761-8256 Date Inspection request received: 12-30-0 2 . Queensbury Building&Code Enforcement Arrive: /0 (a3M)rrt D (pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials:Wart: AV L_j(a NAME: Awew /l✓"ill)ep PERMIT#: 2002— g�4f LOCATION: 1Sxh-)4Y,4&e1 xleod DATE: 12 —3D-102 TYPE OF STRUCTURE Comments Y N N/A Chimney Ht./"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumb Vent through roof Roof Complete Guard 30 in.or more(o),stairs,decks,patios Guard at stairwell at 34 in. or more Guard at deck,porches 36 in.or more Exterior Finish Complete Interior/Exterior Railings 34 in.to 38 in. Platform at all exterior doors V ������-�, Interior Handrails stairs 2 or more risers 4 Grade away from foundation 6 in.with 10 ft. Handrail Termination at Newell Post or Wall 8 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18"above grade Gas Furnace shut-off within 30 ft.or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler 0 Relief Valve(s)installed Interior privacy/trim/doors/main entrance 36 in. Bathroom/Kitchen watertight Safety glazing Window in stairwells safety glazing Interior Smoke Detectors: Every level: Every Bedroom: Outside every bedroom area: _ Inter Connected: / Battery backup: Bathroom Fans,if no window Carbon Monoxide detector Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sf Emergency egress below grade Basement stairs closed rise>4 inches '/4hour fire door/door closer Garage fireproofing 14 rn IL /0 Duct work Sealed properly V1 iJ Attic access 30 in.x 2 in. x 30 in.(ht.)In accessible area J5 0 Crawl Spaces 18"x 24"access, I sq. ft.-150 sq.ft.vents t Building No./Address visible from road 5 Final Electrigat=z, ')Site Plan Variance required Final Sury an Gres As Built Septic System/Sewer Dept.Inspection Sticker Flood Plain Certification, if required Okay to issue C/C(Cert.Of Compliance) Okay to issue Temporary C 0(Cert. Of Occupa cy) Okay to issue Permanent C I 0(Cert. Of Occupan y) Framing/ Firestopping Inspection Report Office No. (518)'161-8256 Date Inspection request received: v� Queensbury Building&Code Enforcement Arrive: am/pm Depart. 11' mlpm 742 Bay Road, Queensbury,NY 12804 Inspector's Initials: NAME: �\j PERMIT#: ) .jqq, LOCATION: INSPECT ON: TYPE OF STRU Y N N/A coNTS Framing ���� Jack Studs/Headers CsL.7 Bracing/Bridging 6!'Vl'�('-�� Joist hangers /� Jack Posts/Main Beams t-� L� L R+r Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in.or more . Headroom 6 ft. 8 in. - Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 '/z(w) 16 gauge(8) 16D nails each side Draft stopping 1,000 sq. ft.floor trusses Anchor Bolts 6 ft.or less on center Ice and snow shield 24 inches from wall Fire separation 1,2,3 hour Fire wall 2, 3,4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side %inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiliri wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade Office Use GENERAL INSPECTION REPORT Inspector: Town of Queensbur Ready at time: Dept. of Community Development Request received: //6h/,)-Z_ Meet: Building& Code Enforcement At time: 742 Bay Road Queensbury, AT 12804 ARRIVE_amIpm: DEPARTRI, la�inl pm Notes: (518) 761-8256 Inspector's Initials NAME: PERMIT# LOCATION; INSPECT ON(date): TYPE OF STRUCTURE: RECHECK � N/A YES NO CoNi� NTS otingiF er Monolithic PourForm Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. vaterials for this purpose on site oundation/Wallpour Z Reinforcement in Place V Foundation/Dampproofing_ Backfill,Approval Plumbing Under Slab .Plumbing Vent/Vents in Place Rough Plumbing_ Heating Rough-In Insulation Foundation Walls Interior R- Foundation Walls Exterior R- Floors R- Walls R- Ceiling R- Duct work or piping in unheated spaces R- Proper Vent,Attic Vent Framing_ Jack Studs/Headers Bracing/Bridging Joist Hangers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1,2,3,hour Penetration Sealed Fire Wall 2,3,4 hour Firestopping_ L:\SueHemingway\Building.Codes.hispection.FORMS\GENERAL INSPECTION REPORT.doc Office Use GENERAL INSPECTION REPORT Inspector: Town of Queensbury Ready at time: Dept. of Community Development Request received: Meet: Building& Code Enforcement At time: 742 Bay Road Queensbuty, AT 12804 ARRIVE am/pm: DEPART Pm Notes: (518) 761-8256 Inspector's Initials NAME: ✓ PERMIT# 6 Z,— LOCATION: INSPECT ON(date): mAlla'- TYPE OF STRUCTURE: RECHECK N/A YES NO COMMENTS Footings/Piers Monolithic Pour Form Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. ,�otM erials for this purpose on site ndation/Wallpour 14 Reinforcement in Place Foundation/D ampproo fing Backfill Approval Plumbing Under Slab Plumbing Vent/Vents in Place Rough Plumbing_ Heating Rough-In Insulation Foundation Walls Interior R- Foundation Walls Exterior R- Floors R- Walls R- Ceiling R- Duct work or piping in unheated spaces R- Proper Vent,Attic Vent Framing Jack Studs/Headers Bracing/Bridging Joist Hangers Jack P6sts/Main Beam Air Infiltration Barrier Fire Separation 1,2,3,hour Penetration Scaled Fire Wall 2,3,4 hour Firestopping L:\SueHemingway\Building.Codes.inspection.PORMS\GENERAL INSPECTION REPORT.doc Office Use OINERAL INSPECTION REPOR40 Inspector: Town of Queensbury Ready at time: Dept. of Community Development Request received: ol- Meet: Building& Code Enforcement At time: 742 Bay Road Notes: Queensbury, AT 12804 ARRIVE am/pm: DEPART am/pin (518) 761-8256 Inspector's Initials U NAME: PERMIT# LOCATION: 15- & INSPECT ON(date): G �/ 13 /�2 TYPE OF STRUCTURE: RECHECK M(ootings/Piers A N/ArYE NO COMMENTS X*2onolithic Pour Form Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. ' Materials for this purpose on site Foundation/Wallpour Reinforcement in Place Foundation/Dampproofing Backfill Approval Plumbing Under Slab Plumbing Vent/Vents in Place Rough Plumbing Heating Rough-In Insulation Foundation Walls Interior R- Foundation Walls Exterior R- Floors R- Walls R- Ceiling R- Duct work or piping mi unheated spaces R- Proper Vent,Attic Vent Framing_ Jack Studs/Headers Bracing/Bridgmig— Joist Hangers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1,2,3,hour Penetration Sealed Fire Wall 2,3,4 hour Firestopping L:\SueHemingway\Building.Codes.Inspection.FORI\4S\GENERAT,INSPECTION REPORT.doc i i a 74t 19 '. ,1 x . - " . . rit Ait Ali .�► 0000 Am IWA too 1*4 Il.,�f� ,t�. -��• � :•G..'. .r'•. 1} ''u yS'4 i�>-:+,•4�'r?+(•S'1•_'k. lllsf"IN �f7 .1 %% './, •(r ^,r 'ems::.. i - Ail INA " .. ..r _ .. _. ...,� _. -- rya•.._. v> liFm ! October 2002 Mr. Howard Nadler Adirondack Dream Homes �sW, 15 Antiqua Road, New York 12845 518-668-9810 Re: Supplemental Design Specifications Insulation Requirements R-60 Roof&Ceilings R-50 Envelope Walls R-60 Floor Over Unconditioned Basement Plans&Specifications Sealed by the Engineer, 9/5/02 Proposed Stg�_a_mily Residence` Dear Mr. Nadler: As we discussed,to meet the New York State Energy Conservation Construction Code effective 3 July 2002,the builder of the above referenced project must meet the following requirements: 1) R-60 cavity insulation in all cathedral ceilings-2"x12"rafters 16"oc This may be accomplished with four layers of two inch Hi R-14 rigid insulation and one layer of 3/41"Hi R-6. 2) R-60 cavity insulation in all flat ceilings. This may be accomplished by two layers of R-30 batt insulation. 3) R-50 cavity insulation in all walls-2"x10"studs 16"oc. This may be accomplished with four layers of two inch Hi R 14 rigid insulation. 4) R-60 cavity insulation in all floors-Same as#f1 above. Also; plea es install a W12x40 steel<girdevover the center line of the I'll a su ortin the f1-- sy emaboe. ----- -- a ,- _.. 9 pp g Please feel free to contact me if you have any questions or comments. rel. , Edward KKoFf,P.E. Ward Lane,PO Box 190 Cieverdale,New York 12820 518-656-3059