Loading...
ApplicationArea Variance [ZBA approved: November 15, 20191 239.12-2-11 Tax Parcel ID Number: WR Zoning District: General Information Detailed Description of Project [include current & proposed use]: The proposed project consists of a new 10' wide paved driveway, +/-1,734 sf building addition consisting of a second story, two bay garage, on site stormwater management and shoreline buffer additions. Location of Project: 42 Old Assembly Point Road Applicant Name: Jeffrey Randles Mailing Address 82 East Claremont Drive Home Phone City, State, Zip Voorheesville NY 12186 Work Phone 518-894-1821 Cell Phone E-Mail: effrey.randles@ymail.com FAX No. r Agent's Name: Environmental Design Partnership Mailing Address 900 Route 146 Home Phone City, State, Zip Clifton Park NY, 12065 Work Phone 518-371-7621 Cell Phone E-mail nzeglen@edpllp.com cdemyer@edpllp.com FAX No. Owner's Name mmASameas Applicant Mailing Address Home Phone City, State, Zip Work Phone Cell Phone E-mail FAX No. Page 1 Area Variance [ZBA approved: November 15, 20191 Site Development Data Area / Type Existing sq. ft. Proposed Additions . ft. Total sq. ft. A. Building footprint 1,630 1,230 2,860 B. Detached Garage _ _ _ C. Accessory Structure(s) 130 0 130 D. Paved, gravel or other hard surfaced area 526 2,273 3,249 E. Porches / Decks 450 (-450) +488 488 F. Other G. Total Non -Permeable [Add A-F] 2,736 3,991 6,727 H. Parcel Area [43,560 sq. ft. / acre] 37.951 37,951 37,951 I. Percentage of Impermeable Area of Site [I=G/H] 7.21% 10.52% 17.73% Setback Requirements Area Required Existing Proposed Front Yard [ 1 ] 30' 228' 189, Front Yard [2] Shoreline 50' 53.75' (adj lots) 49' 46' Side Yard [ 1 ] 20' 8' 8' Side Yard [2] 20' 20' 20' Rear Yard [ 1 ] Rear Yard [2] Travel Corridor Height [maximum] 28' _ _ Permeability 75% 92.79% 82.27% Number of parking spaces _ 4 4 Page 2 Area Variance [ZBA approved: November 15, 20191 Additional Project Information 1. Will the proposal require a Septic Variance from the Town Board of Health? NO 2. If the parcel has previous approvals, list application number(s): SEP-000798-2016 AST-0117-2019 3. Does this project require coverage under the New York State Pollutant Discharge Elimination System (SPDES) Permit Program? _ Yes / x No 4. Estimated project duration: Start Date: FALL 22 End Date: SPRING23 5. Estimated total cost of project: $150,000 6. Total area of land disturbance for project: 10,000 SF Floor Area Ratio Worksheet FLOOR AREA RATIO (FAR) -- The relationship of building size to lot size, derived by dividing the total building floor area by the lot size in square feet, yielding a percentage. Zoning District ■ Symbol Floor Area Ratio [FAR] Waterfront Residential WR 0.22 Commercial Moderate / Commercial Intensive CM / Cl 0.3 A. The combined area of all square footage, as measure from exterior walls of all structures on the property, including all floors of the structures, garages, basements and attics with more than five (5) feet of ceiling height and covered porches. Building square footage does not include: Open deck, docks and that portion of covered docks extending over water and one storage shed of one hundred twenty (120) square feet or less. Any additional sheds will be included. (See "FLOOR AREA RATIO"). B. Commercial or industrial: the total area in square feet as measured from the exterior of the outside walls of a building or structure, and when applicable, the sum total of all floor areas of the principal and accessory buildings or structures on the project site. Parcel Area 17 os i 0 s . ft. Existing Floor Area i (Inn 0 s . ft. see above definition Proposed Additional Floor Area S,iFR 0 s . ft. Proposed Total Floor Area A QASZ 0 s . ft. Total Allowable Floor Area Q gad 0(Area x ),) 0 see above table Page 3 Area Variance [ZBA approved: November 15, 20191 Compliance with Zoning Ordinance Requesting relief from SECTION: 179-4-010 ❑+ Need relief from the requirement(s) listed below which can not be met by the project as proposed. [Check all that apply] %K Setback ❑ Buffer Zone ❑ Lot Width ❑ Other The following questions reflect the criteria for granting this type of variance. Please complete them; use additional sheets if needed. 1. Whether an undesirable change will be produced in the character of the neighborhood or a detriment to nearby property will be created by the granting of this area variance? No, an undesirable change will not be produced in the character of the neighborhood or a detriment to the nearby property. The neighboring parcels views will not be obstructed by the shoreline setback and the setbacks will not encroach on the neighboring parcels any further than as they exist currently. 2. Whether the benefit sought by the applicant can be achieved by some method, feasible for the applicant to pursue, other than an area variance? No, the requested area variance cannot be achieved by some other method. The house is an existing non-confonning structure that is maintaining a similar footprint. It is not economically feasible to move the entire house location to avoid this variance. 3. Whether the requested area variance is substantial? The requested variances are not substantial, the side yard setback is maintained, and the shoreline setback is only being increased by 3 feet (from 49 feet to 46 feet) from the existing. Many improvements are being made on site to limit runoff entering into Lake George, along with and enhanced shoreline buffer. 4. Whether the proposed variance will have an adverse effect or impact on the physical or environmental conditions in the neighborhood or district? The proposed construction with have a positive impact on the physical and environmental conditions with proper stormwater management devices installed on site and additional plantings. 5. Whether the alleged difficulty was self-created? The shoreline setback are not self created, the 46' proposed setback is maintained on the existing structure that is lawful nonconforming, the average distances of the two neighboring parcels is 53.75 feet, which adds additional setback relief from the typical 50 foot setback requirement in this zone. Page 4 Area Variance [ZBA approved: November 15, 20191 Section 179-14-030 Application materials and site plan drawing is to include sufficient information for the Board to review and provide a decision. The applicant is to provide a site plan drawing(s) — a survey showing existing conditions, a proposed conditions map (see page 00 for specific criteria) and include any other attachments that address A - D as applicable to the proposed project. A. General Shown on Sheet # 1 Title, Name, Address of applicant & person responsible for preparation of drawing 2 Deed attached 3 North arrow, Tax Map ID, date prepared and scale [minimum: 1 inch = 40 feet ] 2-6 4 Boundaries of the property plotted to scale, zoning boundary 5 Principal structures, accessory structures with exterior dimensions 2-6 6 Site improvements incl. outdoor storage areas, driveways, parking areas, etc.: existing & proposed 2.6 7 Setbacks for all structures and improvements: existin & proposed 3-6 8 Elevations and floor plans of all proposed and affected structures B. Water & Sewer E Shown on Sheet # 1 Project sewage disposal facilities, design details, construction details, flow rates, and number of bedrooms proposed n/a 2 Water supply [i.e. well] & septic on adjoining lots with separation distances to existing or proposed on -site water supply and septic 2 3 Separation distances for proposed sewage disposal system to well and water bodies 4 Existing public or private water supply [well, lake, etc.]. Method of securing public or private water, location, design and construction of water supply including daily water usage 2 5 Percolation test location and results C. Parkin / Permeable Areas Shown on Sheet # 1 Number of spaces required for project including calculations and justification: existing & proposed n/a 2 No. of existing parking spaces, number to be removed, number to maintain and type of surfacing material [e.g., gravel,paved] n/a 3 Provision for pedestrian and handicap access and parking: existing & proposed 4 Design details of ingress, egress, loading areas and cutting: existing & proposed 5 Location and character of green areas [existing and proposed], modification to green area, buffer zone to remain undisturbed „/a 6 Li htin , location and design of all existing and proposed outdoor lighting D. Additional Site Development and Miscellaneous Shown on Sheet # 1 On -site & adjacent watercourses, streams, rivers, lake and wetlands 2 Utility / energy distributions stem as, electric, solar, telephone]: existing & ro osed 3 Location, design and construction details of all existing and proposed site improvements including: drains, culverts, retaining walls, fences, fire & emergency zones and hydrants, etc. „/a 4 Square footage of bldg. area proposed for office, manufacturing, retail sales or other commercial activities: existing & proposed n/a 5 Si a e: Location, size, type, design and setback: existin & proposed 6 Waiver Request: provide letter with application requesting any waivers: please reference specific items n/a 7 Commercial / Industrial Development requires submission of Landscaping, Stormwater Management, Grading & Lighting Plans „/a 8 Identification of Federal, State or County permits required for the project together with a record of application for all necessary permits n/a Pagc 5 Area Variance Pre -Submission Conference Form / Section 179-9-040 1. Applicant Name: Jeffrey Randles 2. Tax Map ID 239.12-2-11 Locati011• 42 Old Assembly Point Road 3. Zoning Classification wR alterations to an existing single story home with a second story and attached garage,slonnwater and shoreline planting 4. Reason for Review: 5. Zoning Section #: 179-3-040 NR 6. Pre -Submission Meeting Notes: Deed General Information complete Site Development Data Complete Setback Requirements Complete Additional Project Information Complete FAR addressed Compliance with Zoning Ordinance Checklist items addressed Environmental Form completed Signature Page completed Provided Outstanding; Please provide by X x' shoreline setback X X X x NA x Applicant proposes alterations to an existing single family home with a second story addition and an attached garage. The additions include additional basement area of 537 sf. The main floor would alter the north side with a new dining area, a new garage would be included on the main floor 720 sf, then on the south side bedroom areas to be added to the footprint of the structure. The second floor would include 1,498 sq ft with additional bedroom with a deck, bunk room and storage. The project includes stormwater management and shoreline plantings. Site Plan review for new floor area and alteration to the existing home. Area variance for setbacks to the north side 8 ft is proposed where 20 ft is required, stormwater device setbacks 48 ft and88 ft where 100 ft is required, shoreline setback where 51 ft is proposed and required for avg of two adjoining homes. reviewed: site plans, survey variance and site plan applications, elevations, floor plans, ors to be updated or provided: confirm setback for shoreline signature page Staff Representative: Lanm Meore via si2lzozz Applicant /Agent: ►"'U'wLCLS t&(p,(1 At'ea Variance [ZBA approved: November 15, 2019) This page includes the 1.) Authorization to Act as Agent Form: 2.) Engineering Fee Disclosure; 3.) Authorization for Site Visits; 4.) Other Permit Responsibilities; 5.) Official Meeting Disclosure and 6.) Agreement to provide documentation required. ONNER'S AGENT FORM: Complete the following if the OWNER of the property is not the same as the applicant: Owner: Designates: as Agent regarding the following: Variance Site Plan Subdivision For Tax Map No.: Deed Reference: Book_ Page Date OWNER SIGNATURE: DATE: APPLICANT'S AGENT FORM: Complete the following if the APPLICANT is unable to attend the meeting or wishes to be represented by another party: Owner: Jeffrey Randles Designates: Environmental Design Partnership as Agent regarding the following: x Variance Site Plan x Subdivision For Tax Map No.: 239.12-241 Deed Reference: Book_ Page _ Date OWNER SIGNATURE: XUa 4 kaA� DATE: June 13, 2022 V- 2.) ENGINEERING FEE DISCLOSURE: Applications nray be referred to the Town consulting engineer for review of septic design, storm drainage, etc. as determined by the Zoning or Planning Department. Fees for engineering review services will be charged directly to the applicant. Fees for engineering review will not exceed $ 1,000 without notification to the applicant. 3.) AUTHORIZATION FOR SITE VISITS: By signing this page and submitting the application materials attached herein, the Owner, Applicant, and his/her/their agent(s) hereby authorize the Zoning Board or Planning Board and Town Staff to enter the subject properties for the purpose of reviewing the application submitted. 4.) OTHER PERMIT RESPONSIBILITIES: Other permits may be required for construction or alteration activity subsequent to approval by the Zoning Board or Planning Board. It is the applicant's responsibility to obtain any additional permits. 5.) OFFICIAL MEETING MINUTES DISCLOSURE: It is the practice of the Community Development Department to have a designated stenographer tape record the proceedings of meetings resulting from application, and minutes transcribed from those tapes constitutes the official record of all proceedings. 6.) AGREEMENT TO PROVIDE DOCUMENTATION REpUIRED: I, the undersigned, have thoroughly read and understand the instructions for submission and agree to the submission requirements, I acknowledge no construction activities shall be commenced prior to issuance of a valid permit. I certify that the application, plans and supporting materials are a time and complete statement/description of the existing conditions and the work proposed, and that all work will be performed in accordance with the approved plans and in conformance with local zoning regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents, will obtain a certificate of occupancy as necessary. I also understand that Uwe may be required to provide an as -built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy I have read and agree to the above. rCR«�f� Signa [Ap scant Signature Jeffrey Randles Pr��igqt Namees� [Applicant] Print Name [Agent] June 13, 2022 Date signed DateDate sigded �7