2002-966 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building&Codes (518)761-8256 CERTIFICATE OF COMPLIANCE Permit Number: P20020966 Date Issued: Friday,August 06,2004 This is to certify that work requested to be done as shown by Permit Number P20020966 _ has been completed. Tax Map Number: 523400-309-015-0001-059-000-0000 Location: 56 CAROLINE St Owner: CATHLEEN DALY Applicant: CATHLEEN DALY This structure may be occupied as a: By Order of Town Board Deck TOWN OF QUEENSBURY Director of Building&Code Enforcement TOWN- OF QUEENSBURY : 742 Bay Road,Queensbury,NY' 12804-5902 (518)761-8201 Community Development-Building&Codes (518)'761-8256- BUI1DING-,PERMIT:. Permit Number: P20020966 Application Number: A20620966 Tax.Map No: 5234.00-309-015-0001-059-000-0000 Permission is Hereby granted to: CATHT,F,F,N DALY For property located at: 56 CAROLINE St in the Town of Queensbury,to construct or.place , at the above location in accordance with application together;with plot plans-and other information hereto filed and'approved and in compliance with the NYS.Uniform,Building Codes.and.the Queensbury Zoning Ordinance. Terre of Construction _ Value Owner Address: CATHLEEN DALY St CAROLIN 56' E" Deck $3,500.00 QUEENSBURY,NY 12804 Total Value $3,500.00 Contractor or Builder's Name/Address Electrical)inspection Agency HARRY Crn0T)WT1N` LATHAM-NY 12110-0060 Plans&Specifications 2002-966 Construction of a 463.75 sq ft,deck per plot plan and specifications., $46.38 PERMIT FEE PAID-THIS PERMIT,EXPIRES: Sunday,March l,,2004 , (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at ' . wn of ee bu Friday,March 21,'2003 SIGNED BY for the Town of Queensbury. Director of Building kCode Enforcement Porch, Deck, Dock, or Boathouse Permit Application Town of Queensbury—Dept of Community Development,742 Bay Road, Queensbury,NY (518)761-8256 A permit must be obtained before beginning construction. No Permit File No. 7496 � inspection will be made until applicant has received a valid Fee Paid $ building permit. All applicants'spaces on this application must be Reviewed By: completed and must appear on the application form. ApplicantV Owner: �_ c�,` Lees...Z)d L7 Address: Address: (- der - Ald 100-Y Phone# Q�14 ) 7_?� - 09/ Phone#{ ) - Email Address: ,r,hr�y �i��4�T Email Address: Person Responsible for Supervision of Work as Regards to Building Codes: Name �¢ �r , Address: f Phone =�✓�02 Property Location: -Lot Number: / House Number Subdivision Name: Tax Map Number: Estimated Market Value of Construction. $ T 66�e l�—V ❑ Porch' s--� Deck ❑: Dock ❑ Boathouse, A) �f ❑ Other work(describe t 1? )-o Size of structure to be built square feet Submit along with this application: 1. Two plot plans drawn too scale,preferably using a survey map. Indicate proposed structure showing setback dimensions from all-property lines. Show location of water supply and location and configuration of septic disposal area. 2. Two sets of structural drawings. Indicate size of posts or studs, floor joists, decking or flooring material to be used. Show how the porch or deck will be fastened to the building. If a roof will be constructed,indicate the size of posts or studs,roof rafter spacing and span. Indicate type of roof: sloped,flat, shed, or other. Indicate the type of material being used for the roof. Declaration: please sign below after you have carefully read the statement: To the best of my knowledge the statements contained in this application,together with the plans and specifications submitted,are a true and complete statement of all proposed work to be done on the described premises and that all provisions of the Building Code,the Zoning Ordinance and all other laws pertaining to the proposed work shall be complied with,whether specified or noted,and that such work is authorized by the owner. ryry Applicant's signature:. Date: L:\SueHemingway\Building.Permit.FORMS\Porch.Porch.Permit.doc 8/13/02 revised per DH r,. Queensbury Building & Code Enforcement - Residential Final Inspection Office No.(518)761-8256 Arrive: am/p apart: ��m/pm - Date Inspection request received: _ Inspector's Initials: q � , NAME: PERMIT#: 0 LOCATION: � � DATE: >� TYPE OF STRUCTURE: Comments Y N N/A Chimney Ht./"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumb Vent through roof minimum 6" Roof Complete/Exterior Finish Complete Guard 30 in.or more @ stairs,decks,patios Guard at stairwell at 34 in. or more Guard at deck,porches 36 in.or more Exterior Finish Ca late Interior/Exterior Railings 34 in.to 38 in. Platform at all exterior doors Interior Handrails stairs 2 or more risers Enclosed Stairs Sheetrock Underside minimum %" , G sum Grade away from foundation 6 in.with 10 ft. Handrail Termination at Newell Post or Wall 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18"above grade Gas Furnace shut-off within 30 ft.or within line of site Oil Furnace shut-off at entrance to furnace area ; Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Tern 110 Interior privacy/trim/doors/main entrance 36 in. Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: / Every Bedroom: Outside every bedroom area: Inter Connected: / Battery backup: Carbon Monoxide Detector Bathroom Fans,if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sf Emergency egress below grade Basement stairs closed rise>4 inches Garage Floor Pitched 1 Garage fireproofing/1/4 hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Attic access 30 in.x 22 in,x 30 in.(ht.)In accessible area Crawl Spaces I8"x 24"access, I s . ft.-150 s .ft.vents Building No./Address visible from road Final Electrical Site Plan /Variance required Final Survey Plot Plan As Built Se ti stcm/Sewer Dept. Inspection Sticker Flood Plain ertifi ation,if required Okay to iss C/C or C/o Temporary/Permanent L:IPamW\Building&CodeslInspection FormslRes. Final Insp. form 2.docLast printed 2/12/04 Feundation Inspection Report Office No. (5 IS)761-825 6 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/pnjj art:C� 'am/pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: % f NAME: PERMIT#: LOCATION- 4:7 INSPECT ON: !7--9-5-01 TYPE OF STRUCTtTR`9-. Comments Z Y N/A Piers Mo ithic Slab 11 /1 Reinforcement in-Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site, Foundation/Wallpour Reinforcement in Place Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil of for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation insulation Interior/Exterior R- Rough Glade 6 inch drop within 10 ft. L:4SueHemin8way\]3uilding.Codes,lnspection.FORMS\Foundatioii Inspection Report.doe January 28,2003 QueensburY Building & Code-Enforcement - Residential Final Inspection V,6nAA .. Office No.(518)761-8256 Arrive: am/pm ''�;piL Date Inspection request received: nspector's Initials: C -1 NAME: PERMIT#: LOCATION: DATE: TYPE OF STRUCTURE: Comments Chimney Ht./"B"Vent/Direct Vent Location Fresh Air Intakef� - 3 inch Plumb Vent through roof minimum 6" Roof Complete/Exterior Finish Complete Guard 30 in.or more @b stairs,decks,patios Guard at stairwell at 34 in, or more y I � � -rill, 14 C.- L. ,��ivt Guard at deck,porches 36 in.or more Exterior Finish Complete Interior/Exterior Railings 34 in.to 38 in. 4,2 Platform at all exterior doors > U 5I Interior Handrails stairs 2 or more risers �— Enclosed Stairs Sheetrock Underside minimum '/" Gypsum Grade away from foundation 6 in. with 10 ft. Handrail Termination at Newell Post or Wall 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18"above grade Gas Furnace shut-off within 30 ft. or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 Interior privacy/trim/doors/main entrance 36 in. Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: i Every Bedroom: Outside every bedroom area: Inter Connected: / Battery backup: Carbon Monoxide Detector Bathroom Fans, if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sf Emergency egress below grade Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/'/4 hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Attic access 30 in.x 22 in.x 30 in.(ht.)In accessible area Crawl Spaces 18"x 24"access, 1 s . ft.-150 s . ft.vents Building No./Address visible from road Final Electrical Site PIan /Variance required Final Survey Plot Plan As Built Septic System/Sewer Dept. Inspection Sticker Flood Plain Certification, if re uired Oka to issue C/C or C/4? Tem orar /Permanent L:\PamW\Building&Codesllnspection Forms\Res.Final Insp. form 2.docLast printed 2/12/04 Queensbury Building & Code Enforcement - Residential Final Inspection Office No.(518)761-8256 Arrive: am/ t e t: ��am/pm Date Inspection request received: Inspector's Initials: t�/ / NAME: '\ l E? \ n PERMIT#: 0 LOCATION: N 0 DATE: TYPE OF STRUCTURE: Comments Y N N/A Chimney Ht./"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumb Vent through roof minimum 6" Roof Complete/Exterior Finish Com lete Guard 30 in.or more @ stairs,decks,patios Guard at stairwell at 34 in.or more Guard at deck,porches 36 in.or more Exterior Finish Complete Interior/Exterior Railings 34 in.to 38 in. Platform at all exterior doors Interior Handrails stairs 2 or more risers Enclosed Stairs Sheetrock Underside minimum ''/z" Gypsum Grade away from foundation 6 in. with 10 ft. Handrail Termination at Newell Post or Wall 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18"above grade Gas Furnace shut-off within 30 ft. or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 Interior privacy/trim/doors/main entrance 36 in. Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety Pzin Interior Smoke Detectors: Every level: / Every Bedroom: Outside every bedroom area: Inter Connected: / Battery backup: Carbon Monoxide Detector Bathroom Fans,if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sf Emergency egress below grade Basement stairs closed rise>4 inches Garage Floor Pitched i Garage fireproofing/'/4 hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Attic access 30 in.x 22 in.x 30 in.(ht.)In accessible area Crawl Spaces 18"x 24"access, I s . ft.-150 s . ft.vents / Building No./Address visible from road Final Electrical p V Site Plan /Variance required 1 Final Survey Plot Plan As Built Septic System/Sewer Dept. Inspection Sticker Flood Plain Certification, if required Okay to issue C/C or C/O Temporary/Permanent] L:\PamW\Building&CodesUnsuection FormslRes, Final Inst3. form 2.docLast printed 2/12/04 Queensbury Building & Code Enforcement - Residential Final Inspection Office No.(518)761-8256 ► Arrive: arm/ Depart, am/pm Date Inspection request receiv 0 p4yL Inspector's�Initia�ls• NAME- PERMIT#: 0 NL CD LOCATION: DATE: 15104 TYPE OF STRUCTURE: Comments Y N N/A Chimney Ht./"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumb Vent through roof minimum 6" <� Roof Complete/Exterior Finish Complete Guard 30 in.or more @ stairs,decks,patios —1 Guard at stairwell at 34 in, or more Guard at deck,porches 36 in.or more Exterior Finish Complete Interior/Exterior Railings 34 in.to 38 in. 00 Platform at all exterior doors Interior Handrails stairs 2 or more risers /10 Enclosed Stairs Sheetrock Underside minimum 1/2" Gypsum Grade away from foundation 6 in.with 10 ft. Handrail Termination at Newell Post or Wall 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18"above grade Gas Furnace shut-off within 30 ft. or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Trap/Water Temp 110 Interior privacy/trim/doors/main entrance 36 in. Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors: Every level: _ / Every Bedroom: Outside every bedroom area: Inter Connected; — / Battery backup: Carbon Monoxide Detector Bathroom Fans,if no window Plumbing fixtures Foundation insulation Floor truss, draft stopping finished basement 1,000 sf Emergency egress below grade Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/3/4 hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass Enclosure Attic access 30 in.x 22 in.x 30 in.(ht.)In accessible area Crawl Spaces 18"x 24"access, I sq. ft.-150 sq.ft.vents Building No./Address visible from road Final Electrical Site Plan /Variance required Final Survey Plot Plan As Built Septic System/Sewer Dept.Inspection Sticker Flood Plain Certification, if required Okay to issue C I C or C/0[TernporaEy/Permanent L:\PamW\BuildinR&CodesUnspection Forms\Res.Final Insp. form 2.docLast nrinted 2/12/04 )JA' RI Foundation Inspection Report Office No. (51-8)761-8256 Date Inspection request received: JA Queensbury Building&Code Enforcement Artive: am/p Depart: - am/pm 742 Bay Rd., Queensbury,NY 12804 Inspector's Initials: NAME: ^� , PERMIT#: LOCATION: INSPECT ON: 3 TYPE OF STRUCTURE: Comments Y N /A ootings Piers C�L l-- t� �--' to ti Monolithic Slab Reinforcement in Place " + The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place a Foundation Dampproofing Foundation/Waterproofing Type of Dampproofing/Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under.Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Cn ade 6 inch drop within 10 ft. L;\SueHemingwayiBuilding.Codes.Inspection.FORMSIFoundation Inspection ReporLdoc January 28,2003 RECEIVED ,,. .: Nov 18 2002 7�OW" 31NC AID CODE 0 C �. aai ttuy i v.�o...�. post-Layout for Deck 3 �/(� SC�L•t��4 �if tij4if v � IF Ci M ..t 2 � { 5 r The purpose of this is to provide a general outline of the layout of the substructure of the design. Be sure that this design meets your needs and local building code requirements. Some building codes require that the beams be fastened together on the same side,notched into the side of the post. Please consult your local building department for your code requirements and nailing techiques. (� �� � � �° �r rf � I� N �- ,, 3�! l( cf i �- �� � Z I' S1A( 1 4-21X lcl� S f I + _ 3 r 4 � f�1 d'IA qz j 1� V J onoVI i I r i d l n j fy�o� i�I hit t I(toVid � I V Lowe's Project uesign aysieny QLVRW Sat Aug 1716:20:52 2002 Post-Layout for Deck 1 0 CO w � � --_-------------------■ :s -21' 1VTT ------ 20' O r 211 i \ 10'r I I I t ----------------- —I I ' I I ' I I 15 t I 14' 11" I I I t I t ' I I I I 11'----�--■ � I 11 I I j t I I f I I I I I I �T lrT I I " 6T ' I t I I I I t I t I 1' 10" \ TT l .._.._.._..1........tI-__ --------------- ---- 22 3" _ ._,._.._ _ Deck O 6r _ M ID ---------------------------- --------------- asePoint The purpose of this view is to provide a general outline of the layout of the substructure of the design. Be sure that this design meets your needs and local building code requirements. Some building codes Please contsult your local building department for�your code requirements equirements and nailing techiques. Lowe's Project Design Systernt'7Luru VOY 1,.awe c Sat Aug 1716:21:25 2002 Post.Layout for Deck 2 r ` N CO Ln w w w --3 r—3---------------- 4 I � I i I I I r-- ------------------------------ -........ ".................................................... I I Deck 2! F, I I w {'•7 w I I 4t I t 1 I ( I I I I I I I I t I I ' I I 241 6" I I I I I I I I ' � I ; i I ----- I I i i I I I I � asePoint _. ._._._._. -- - -- - -- - ---- --- ........... •-•-•-•-.--•-•-.-•-•- ----------- ---.-.-.-•-•- -- i i i . i out of the substructure of the The purpose of this view IS to provide your r o it needs and locaeral line of the building coderequirements. Some building codes Be sure that this design m y into the side of the Please chat the onsult yourmoat building depgartment far your coderequirements and nailing techiques. Lowe's Project Design System,Score u"17 Sat Aug 17 16-.23*312002 Post,Layoulfor Deck 4 --------------- ---------------- -------------- t t I I } i 1 I I t I I 1 t � I t I t } i } I t 1 j 1 } t I { I } I o> i I N p tJV O N O i ( - e 71 6"7 t 911 r \ 1 6.1 5' 11" I j 31 1n 31 1"— i 11 31111 6 �\ 1 3"11 i i ----------------------31' 3"--------------------_Deck 4 $a seP01T1t - - - - ' F-` N F.+ p „, O O i i i IV - i i i The purpose of this view is to provide a ge ne outline of the layout of the substructure of the design. rBe equire that the beams design be meets your fastened together d local the same side,notchoode ed into the side of the Some building codes Please consult your local building department for your code requirements and nailing techiques. aai^UH i. ------ post.Layoutfor Deck 3 W N 31 -,3 - . ...................:.... ........................................ All 0 Deck 31 i F' 24, 6" ------- BasePoint The purpose of this view is to provide a general outline of the layout of the substructure of the design. Be sure that this design meets your needs and local building code requirements: Some building codes Please consult yourpotal budding department for your code t requirements and nailing t chiques. bat Aug -11 1 O;A,4;u4 AVww- Post.Layout for Deck 3 The purpose of this is to provide a gen;ral outline of the layout of the Substructure of the design. Be sure that this design meets your needs and local building code requirements. Some building codes reuire that the beams be fastened together on the same side,notched into the side of the post. Plqease consult your local building department for your code requirements and nailing techiques. 5Iaq 0 lM I ,3 ~I � 1 � r., TOWN OF QUEENSB' URY CUSTOM VIEW BUILDING CUSTOMER -- GENERIC CUSTOMER UILDI ` p DEPT, DATE 03/19/03 REF Deck03078 REVIEWEo BY � rJ [SATE 3 ....q naedOn Our,hgede�a a a{ ��mplfarr�2�titi�hour�t►t�(sshali nelbenansl rued asindica(ingte pans and i6c �iens are in foil °: crriiance with the ace, 41. '-opy kf } i' a � •a�yr>�e�vj: � E ,;"•:fir,;;,+ `i STORE NAME tP 123 STREET'AD, �odUP�� CITY, ST SO) 656 1212 s BEAM LAYOUT FOR LEVEL 2 STORE NAME CUSTOMER -- GENERIC CUSTOMER 123 STREET RD. DATE 03/19/03 REF Deck03O78 CITY, ST (800) 666 1212 (L tU --• tU N - B 2' 2 1/2' D 23' 5 1/4' A - CU O d ru BEAM BEAM POST POST LABEL LENGTH COUNT SPACING A 2' 8 3/4" 2 1' 4 1/4" B 4' 6" 2 3' 1-I/2" C 24' 2 1/2" 4 7' II.3/4" D 17' 5 1/2" 3 8' 7" Post spacing is measured center-to-center. Depth of post-in-concrete footers --- 36 inches. P�Afl VIEW FOR LEVEL'. '2 STORE, NAME CUSTOMER,,-- GENERIC CUSTOMER":, ,, ; ' 123 STREET ,, DATE DATE 03/19/03 REF'` D`eck03078 ' CITY,--ST (800) '555 IM f3'6' _ 6'10' 3, ;f'8' 4'3. , LOAD AND SUPPORT: `Your deck will support a 67 PSF live load;: Posts hove' 36" .below-ground ` post support. --DECK WAND 'POST HEIGHT:. You selected-a height of 36 .from the-top of :;decking to._Ie4bI'ground. The top of the'.deck< support posts will therefore be ,27,25 above.ground level.' `Your, salesperson can,provide information for 'uneven or sloped ground:., ' JOISTS: _Set Joists on-,.top of beams, -16".center, to center. NOTE:' The, design may require knee braces- and bridging between joists. Your materials, list includes ''the necessary items. .-The 'suggested design is• notea finished building, plan_ ;You, are'responsible for all measurements being';correct, for verifying that the design (and any' substitutions or-'modifications; chat y.ou .make) meets all local building codes and requirements. "To verify' that. the suggested- design, and any substitutions or modifications, his consistent- with conditions at, the construction site; review the'design with ;your 'architect: Also consult.,our 'architect for proper construction and use of.'materials in, the structure.. Be sure .to .folloW. the deck construction.-,,detail available from your store,salesperson. PLAN VIEW ,FOR LEVEL l STORE NAME CUSTOMER -'; GENERIC CUSTOMER. 123 STREET .RD. DATE 03/19 03 REF `Deck03078 C1TY,':5T '(8001.' 655,`1212 2 4 3'3 3/4' 2'4' ti iv 2 4` 3'3 3/4• 2'4' LOAD AND ,SUPPORT:' Your deck, will support- a 222' PSF live]oad.: Posts°have 36"`below-ground' , post support. ; DECK AND POST HEIGHT: You selected, a,height, of 36" from' the top of decking•to level.ground. The top of the deck support posts will-,therefore.be 27.25"- above ground le.vel_`,, .Your. salesperson a can provide`information for; uneven or _sloped`ground., JOISTS: Set joists'on top .of beams,`.16" center.to center. NOTE: :The design may require knee` braces,and`bridging between joists. :.Your.materials list includes the necessary items. The .suggested design is not ;a finished building--plan. -You .are responsible for ' all measurements being correct, for verifying that the.,desigri land .any substitutions or,modifications ,that you make), meets all local building 'codes and re,quir,ements. -.To verify that the .suggested design," and :any substitution's or modifications, is consistent 'with conditions at the construction site,. .. • rpview`-the•design with-your architect- Also consult..your •architect;for proper, construction and use of materials in the structure: " Be sure to follow the.deck construction ;detail available from your store salesperson. " a BEAM LAYOUT FOR LEVEL I STORE- NAME CUSTOMER --' GENERIC CUSTOMER 123 .STREET RD. DATE 03/19/03' REF Deck03078 .,- CITY, ST. (800). 555 1212 ru BEAM BEAM.r POST POST LABEL 'LENGTH COUNT SPACING A 5' S 1/2" 2 5' 2" B 5' 5 1/2" 2 . 5' 2" Post spacing is measured center-to-center. Depth of post-in-concrete footers --- 24 inches. Y8 ' ,) MAP REFERENCE: MAP OF A SURVEY MADE FOR VILNIS NEILANDS DATED: AUGUST 31, 1994 LAST REVISED: SEPTEMBER 18, 1996 BY: VANDUSEN & STEVES, LAND SURVEYORS � an D u s en 8c Steves Land Surveyors, LLC 37 Chester Street Glens Falls, New York 12801 (518) 792-8474 New York lAc. No. 50135 I.P.F. W I� 131-8— IGgT 9MWITICSM ALTSTATON ON ADDITION TO A SURVEY � LAW SUWICV Rs SAL IS A Mgap of a Survey made for MAP WEAPON A W AI M OF WC3 0I1 73ft 11Y-004" ; OF THE NEW YOMM STAt M M IM IAM• •OIL" WISS FIRM TE MMAL. OF TIM9 SURVEY INMI® ISM AN ObSNAL OF TIE LAW "VIYM NXIM UNS NMATED HVISON SOMI Y TNAT SCA`WAL" SMIMNSCONSWEND ro`"" ` W rIfII TC TSS"O EYIS �ARlD w ALAW CA'1'rHLEEN L. DALY SUW eanw DDot a wacna 1oOR 1AN0 suRTEYDRs ASO►� IT WE LOW TORM SUN ASN" ION OF ►ROPLSSo& LAID bbVETTMt I= Corflr1CATONt SHALL RUN OILY TD TIE PaSON FOR SM TE SIAVEY IS PAEPA141% Alb ON NSt N1MlF M THE TTE 0WANY. O0IFNINEIITAL AMM Alb LANI N @WWI= USIED NOOK AND Town of Qutieensbury, Warren County, New York v0 TIE A11110= a WE UNNS SNRMION.• STET NO. I DATE w RECEIVED ED NO V 1 8 2002 TOWN OF QUEENSBU �SUILDIN RY I HEREBY CERTIFY THAT THIS MAP WASH DE FROM AN ACTUAL FIELD SURVEY. THIS CERTIFICATION SHALL RUN ONLY TO THE PERSONS FOR MOM THE SURVEY WAS PREPARED. AND ON THEIR BEHALF TO THE TITLE COMPANY. GOVERNMENTAL AGENCY AND LENDING INSTITUTION LISTED HEREON. CERTIFICATIONS ARE NOT TRANSFERABLE TO ADDITIONAL INSTITUTIONS OR SUBSEQUENT OWNERS. CERTIFIED TO: CATHLEEN L. DALY M & T MORTGAGE CORPORATION. IT'S SUCCESSORS AND\OR ASSIGNS TICOR TITLE GUARANTEE COMPANY STATE OF NEW YORK MORTGAGE AGENCY. IT'S SUCCESSORS AND\OR ASSIGNS CERTIFIED BY: MATTHEW C. STEVES, LLS NYS 50135 DATED: August 24, 1998 DESCRIPTION iatei AuuuJ i C-+, 1: Scale 1"=50' S --1 SHEET 10F 1 CLUTE DWG. NO. 94126—E 00 I