Loading...
SEP-0538-2022 GARRY ROBINSON, P.E. LETTER OF CONSULTING ENGINEER TRANSMITTAL 114 Monument Drive, Schuylerville,NY 12871 Phone and Fax: (518) 695-3655 DATE: 8, JOB NO.: RE' I TO: WE ARE SENDING YOU Attached ❑ Under separate cover via the following items: ❑ Shop Drawings ❑ Prints Plans ❑ Samples/JVOther l ❑ Specifications ❑ Copy of Letter ❑ Change Order ❑ Computer edia COPIES DATE DESCRIPTION aff n ntF G 3 0 2022 THESE ARE TRANSMITTED as checked below: T BUILDING�ENRm Y DES ❑ For approval For your use ❑ As requested ❑ For review and comment El . PRINTS REM43D AFTER LOAN TO US ❑ Other REMARKS: GLf�P�' �1�so/' r '-71'9 `G:�^�'=� A COPY TO: SIGNED: Y~ W�4 CompaaYdo�ammalGRFosm�\GRTStAN SEPTIC VARIANCE Office Use Only Permit#: 0JS•207.2. APPLICATION Permit Fee:$ t Wb — rin,�r of Qirccrtc6un' Invoice#: 742 Bay Road,Queensbury,NY 12804 P:518-761-8256 www.gueensbury.net Approvals: Submittal: 1 (on ies of the completed application package PLEASE P P SE INCLUDE AN EMAIL Section 1: AVG 30 �0P2 Contact Information: T WM OF OUEENgBUIL gURY I & CQpEs Property Owner(s): 0 ner's Agent: Address: Address: Phone#: O ��JJ�� ��.�� Phone#: Email: Email: e Section 2: Site Information: /U- / Site Address: 22 L.. �L-,,-1., j S.g4e �hJlAl f� Tax lD#: Directions to Site: wt,4 9, Agam w,� �� � � 13°1�Aarn Section 3: o Distance from well on property to septic system (if applicable) feet � 61 ; Section 4: Is it possible to install a conforming septic system on this property? ❑Yes No S,Ve S*' /yP 6A-Y77! If YES, please explain and attach a diagram: Section 5: Does the proposed system meet setback requirements for distance from wells&septic systems on neighboring properties? Xyes ❑ No If NO, please explain: Section 6• Is the proposed system to be installed under a parking area? ❑Yes No Section 7: Section of the Sanitary Sewage Ordinance from which you are seeking the variance (i.e. leaching system wi be 9 ft. from well in lieu of required 100 ft.). d D Septic Variance Application ` ; V; s `Rgvtseec�tnf3� PLEASE ATTACH THE FOLLOWING TO YOUR APPLICATION: 1. A location map showing the site within the Town of Queensbury 2. A plot plan showing existing and proposed features of the property, including: a. Lot dimensions b. North arrow and scale: 1 inch=40 feet c. Location & dimensions of existing and proposed buildings, showing setback distances and uses d. ParkingJayout to scale (if applicable) e. Physical features (street, steep slopes, lakes,wetlands, etc.) f. Location of all wells and septic systems on neighboring properties g. Adjacent ownerships h. All properties within 500 feet A sample plot plan and location are shown below: '�.�,..�.a�.,-� 1� � . Rom, �_.,r-�;,. sarae��er►r� �� a" �. �ll 3"�": '� ? t. F� �•ae'�y. 1 ji{333 f? Aulp - 5 S4 - . r .. i —�3s� . Septic Variance Application Revised December 2021 Section 8: List the names, parcel addresses, and tax map numbers of all adjoining property owners. You may obtain this information from the Town of Queensbury's Assessor's Office: North Name cTD E V,,—,Ily Address PAV Tax Map ID 2 L15?- 3 _9 South Name B ! dU Address Tax Map ID East Name , Address �1rrrA 1244 ' Tax Map ID a216011 "" Q West Name Address �� Tax Map ID Section 9• OWNER STATEMENT I/We do hereby relieve the Town of Queensbury from any liabilities on the plumbing and septic system located at: 4r4+7 L4 I/We realize that putting the well, septic tank or leaching system less than the required _/J&feet from the u/Q_GI may increase the risk of pollution. Owner—Print Name: �! Owner—Signature: Date: .� Section 10: NEIGHBOR OR TENANT RELEASE STATEMENT(if applicable) IVX I/We do hereby relieve the Town of Queensbury from any liabilities on the plumbing and septic system located at: I/We realize that putting the well, septic tank or leaching system less than the required feet from the may increase the risk of pollution. Neighbor/Tenant—Print Name: Neighbor/Tenant-Signature: Date: septic variance Application Revised December 2021 Section 11: AUTHORIZATION AND SIGNATURE PAGE This page includes the Authorization to Act as Agent form, engineering fee disclosure, authorization for site visits, other permit responsibilities and agreement to provide documentation required. Complete the following if the OWNER is using an Agent: owner's Name: Designates: le; ryo/ 9=Jffi as agent regarding the Septic Variance for 122 Site Address: D� � �1 & r , Tax Map#: _ �.�q Engineering Fee Disclosure: Applications may be referred to the Town consulting engineer for review of septic design, storm drainage, etc. as determined by the Town Board of Health. Fees for engineering review services will be charged directly to the applicant. Authorization for Site Visits: By.signing this page and submitting the application materials attached herein,the Owner, Applicant and his/her/their agent hereby authorize the Town Board of Health, building and code Enforcement Officers and Town Engineer to enter the subject properties for the purpose of reviewing the application submitted. Please Note: Other permits may be required for construction or alteration activity subsequent to approval by the Town Board of Health. It is the applicant's responsibility to obtain any additional permits. Official Meeting Minutes Disclosure: It is the practice of the Town Board of Health to have a designated stenographer tape record the proceedings of the meetings resulting from the application, and that the minutes transcribed from those tapes constitute the official record of all proceedings. If there is a discrepancy between such record and the handwritten minutes taken by the designated stenographer,the handwritten minutes shall be deemed the official record. I,the undersigned, have thoroughly read and understand the instructions for submission; agree to the submission requirements and completed checklist: OWNER—PRINT NAME: a It OWNER—SIGNATURE:�o � DATE: AGENT—PRINT NAME: AGENT—SIGNATURE: DATE: S� " Septic Variance Application Revised December 2021 8/19122,12:57 PM 1 I .—_.-.,.- ,_.__..--... R•' - _- �_ - ---_ - .ter,.;.,;:...,.q5��. _ '�``` _-,��^J�.UJ�// ,.� ••,�in .� �••` ;��.y�t .� t4,.ihr;t.-:;L, :g.;:;iigti;�{` a Selected Parcel: 226.19-1-60 mil! Sa,'ty;;< � �::..•> FI® 12208ik = , ..4 y:<� �{••fix: ., � 'a, � - - 'A•g•'e,"°' NE1fl4NlJM6ER 226.19-1-60 �" ._�.z` .�.:-',',.� •:r.�- '��, tslSACRES 1O.343095988O35202 :;-y. RPS fi6L-225, 1-T a c•.SBL 22G.i9 7;b2 .-: SBL:226.1. 7; �. YNER:• TOSINX21 FAfd:IL. TRUST VAUCNV�R . . .m•: ,---1 ER:!TNOtr?ASS'J,�IAUGNAc7AWER.THOIN _q + �O/l°fER. # ��mf:°t..:. 14'�„c,TIC�`•''r gy, ,t Legend 22f?9-? '0 WIVE TOBItVZP2?`FAfn/L5'TRUST. Layer List zc Waterlines vvNER".ro, CD ® Streams 0 Flood Zones s. 0 Critical Environmental Areas }` 0 Mapped DEC Wetlands IN Mapped APA Wetlands = }•_ °s a' N s.,.- .A;ti : ® NW1 Wetlands _ ^- 'fix "{r: -_ -�_;} , `ar�=;�� '• � `;'ff �_; 81 smN _ , x ' '� Y fie. _ :�:- ''•-..a'._:'�:n 'di Y Z' .+jt Measure t i. •.: a .- � .'Y ., ., ..J.,U&.L..i :i-Q6 8 VVNER.'CHRISTINE LECCE B fOi11NER'G1fRt.'TJNE LECCE'; .. uffers Abut ers Draw } . Print Tools -- --- __ �s�p`';T'fiBL:22b.i9�1.3 OY.'NER.ZESLIEYKILLEE,tiJU : '4455`YEFt'LESLIEB lQLLFE,�i, "' AS" y'� ` i httpsd/gbygis.queensbury net/webapp/default.htmi?pid=226.19-1-60 1/2 SEPTIC DISPOSAL PERMIT Office Use Only APPLICATION Permit#: 2©Z2.- zamoff:Wen uy E g' � Permit Fee:$ e5 Invoice#: {, �" � 0�1 (o -2022.) 742 Bay Road,Queensbury,NY 12804 q P:518-761-8256 www.queensbury.net DEC 8 Septic Variance?IS �, TOWN Ot` =iUiErNSStURY Flood Zone? No ni Wetlands? No Reviewed By:✓ Project Location: 22 North Lane Tax Map #: 226.19-1-60 RESIDENCE INFORMATION: Septic Holding Tank Design Year Built Gallons #of bedrooms: X gallons per =total daily flow per day bedroom Garbage Grinder Yes No 1980 or older 150 Installed? (choose one) ❑ lY l 1981-1991 130 Spa or Hot Tub Yes No 1992-Present 110 4 110 440 Installed? (choose one) , ❑ PARCEL INFORMATION: Topography ❑■ Flat Rolling Steep Slope 1 % Slope Soil Nature ❑ Sand ❑ Loam ❑ Clay 0 Other, explain: NA for Holding Tank Groundwater At what depth? 1 foot Bedrock/Impervious material At what depth? . Deeper than 6 feet Domestic Water Supply ❑� Municipal ❑ Well (Lake (if well or lake, water supply from any septic system absorption is ft.) Percolation Test Rate: NA per minute per inch (test to be completed by a licensed engineer/architect) PROPOSED SYSTEM INFORMATION: Tank size NA gallons (min. size 1,000 gallons, add 250 gallons for each garbage cylinder or spa/hot tub System Absorption field w/#2 stone Total length ft.; Each Trench ft. Seepage Pit w/#3 stone How many: ; Size: Alternative System Bed or other type: Holding Tank System Total required capacity? 4000 ; tank size 2000 Design 1000 gal. per Bedroom # of tanks 2 Septic Application Revised July 2022 CONTACT INFORMATION: PLEASE PRINT LEGIBLY OR TYPE, PLEASE INCLUDE AN EMAIL • Applicant: Name(s): Sean Chant Mailing Address, C/S/Z: 22 North Lane,Assembly Point Cell Phone: 518-350-8259 Land Line: NA Email: chanksk7@yahoo.com • Primary Owner(s): Name(s):. Sean Chant Mailing Address, C/S/Z: 22 North Lane,Assembly Point Cell Phone: 518-350-8259 Land Line: NA Email: chanksk7@yahoo.com ❑ Check if all work will be performed by property owner only • Contractor: Contact Name(s): Jeff Lake Contractor Trade: Septic Installer and Pumper Mailing Address, C/S/Z: 11 Jones Road,Saratoga Springs NY Cell Phone: 518-522-9807 Land Line: 518-584-5473 Email: NA **Workers' Comp documentation must be submitted with this application** • Engineer(s): Name(s): Garry Robinson Mailing Address, C/S/Z: 114 Monument Drive,Schuylerville,NY Cell Phone: 518-796-4265 Land Line: NA Email: grobinsonpe@gmail.com Contact Person for Compliance in regards to this project: Garry Robinson Cell Phone: 518-796-4265 Land Line: NA Email: grobinsonpe@gmail.com Declaration: Any permit or approval granted which is based upon or is granted in reliance upon any material representation or failure to make a material fact or circumstance known by or on behalf of an applicant, shall be void. I have read the regulations and agree to abide by these and all requirements of the Town of Queensbury Sanitary Sewage Disposal Ordinance. PRINT NAME: Sean Chant SIGNATURE: ', . J/ R4Th DATE: 12/12/23 Septic Application " Revised July 2022 RESOLUTION GRANTING SEAN CHANT AN EXTENSION OF TIME TO COMPLETE WASTEWATER SYSTEM ALTERATIONS ON PROPERTY LOCATED AT 22 NORTH LANE, QUEENSBURY RESOLUTION NO.: 66,2022 INTRODUCED BY: Mr.Anthony Metivier WHO MOVED ITS ADOPTION SECONDED BY: Mr. George Ferone WHEREAS, by Resolution No. 380,2018, the Queensbury Town Board adopted Local Law 2 of 2018 entitled "Septic Inspection Upon Property Transfer" which is set forth at Queensbury Town Code Chapter 137 (Chapter 137), and WHEREAS, by Resolution No.: 176,2019,the Town Board adopted Local Law 5 of 2019 and by Resolution No. 47,2020, adopted Local Law 1 of 2020 to make additional minor modifications to Chapter 137, and WHEREAS, Chapter 137 requires inspection of Onsite Wastewater Treatment Systems (OWTS) prior to the sale of certain real property and provides that a $2,000 escrow deposit will be forfeited to the Town in the event that completion of a wastewater treatment system meeting all standards is not completed within the time provided as established by Chapter 137, and WHEREAS, by letter dated August 10, 2022, Sean Chant (Applicant) has advised that he will be unable to obtain a variance from the Town Board serving as the Town's Local Board of Health necessary for the completion of the installation/construction of a new wastewater treatment system on his property located at 22 North Lane in the Town of Queensbury before September 1st, 2022 and therefore, the Applicant has requested that the Town Board grant him additional time or until December 15th, 2022 to obtain the variance and complete such work and to extend the date on which the $2,000 escrow deposit he previously deposited with the Town shall be automatically forfeited to the Town, and WHEREAS, the Acting Director of Building and Codes Enforcement has recommended Town Board approval of this requested extension, NOW,THEREFORE, BE IT RESOLVED, that the Queensbury Town Board, as the Town's Local Board of Health, hereby authorizes and grants Sean Chant additional time or until December 15th, 2022 to obtain a certificate of compliance from the Town's Building and Codes Enforcement Office as set forth in Chapter 137 for installation/completion of a new wastewater treatment system located on his property at 22 North Lane, Queensbury and to extend the date on which the $2,000 escrow deposit shall be automatically forfeited to the Town until such date of December 15th, 2022 as delineated in this Resolution and authorizes and directs the Town Supervisor and/or Acting Director of Building and Codes Enforcement to and take any and all actions necessary to effectuate all terms of this Resolution, subject to the condition of no rental of the property after September 15th, 2022 until the new wastewater treatment system has been approved and installed. Duly adopted this 22nd day of August, 2022, by the following vote: AYES : Mr. Metivier, Mr. Ferone, Mr. McNulty, Mr. Strough NOES : Mr. Freer • ABSENT : None w 1 ® 1 1 Z o< Q Z Z z¢ J Q J 1 I N 17'12.55'E 0.77' TO 1. P. R: // LANDS N/F OF S76104'00"E JOHN E. KELLY III 150.00' PROPOSED 2D00 GALLON PRECAST CONCRETE HOLDING (SEPTIC) TANK 10' MIN. TO PROP. LINE �+ 50' MIN. TO WELL PROPOSED 2000 GALLON PRECAS 10' MIN. TO HOUSE CONCRETE HOLDING (SEPTIC) TAt 10' MIN. TO PROP. LINE 50' MIN. TO WELL 1 10' MIN. TO HOUSE 1 r / 4' PVC BUILDING SEWER , ® 10' MIN. TO HOME / AREA \ N 0.344f ACRES / 1 I Z I Sr014 y n y &eDp, 7puCT &RE. a 102� SE I I , n I � , ' I � m , m m ° W m 1 1 EXISTING WELL 1 o i A P P R O X I M A T E ° 1 1 L O W A R E A (W E T) m 1 ° \ W ° ° m Cu�wtT ° e ° s J NORTH LANE l \ ALARM LIGHT! PROVIDE SEAL OFF - FITTINGS IN ACCORDANCE WITH NEC AND 10 STATES STANDARDS TO PREVENT MOVEMENT OF GAS INTO THE CONTROL PANEL ALARM PANEL -WALL MOUNTED ON f -BUILDING EXTERIOR (SEE DETAILS BELOW) MOUNTED SECURELY TO A POST OR BUILDING 4"0 SCREENED PVC VENT (SHOWN HERE FOR CLARITY) INSTALL FREE STANDING OR RUN TO BUILDING MIN 2' ABOVE GRADE FINISHED GRADE IF ODOR BECOMES A PROBLEM INSTALL AN ODOR CONTROL CARBON CANISTER AT THE END OF THE VENT PIPE CONDUIT/POWER 4"0 PIPE - �- FROM BUILDING FROM HOLDING FLOAT SWITCH ELEVATIONS HIGH LEVEL ON ® .5 AFF ENERGIZE YELLOW LIGHT SHUTOFF LEVEL ON A 4.0' AFF ENERGIZE RED FLASHING LIGHT, ENERGIZE BUZZER k ENERGIZE SOLENOID VALVE TANK NO. 1 SLOPE 1/4 /*FT. MIN. AREA PLAN - SEPARATIONS .7VX.i.: 1w-60 FE&T 2" PVC CONDUIT WITH LEVEL SWITCH AND POWER WARES -SEPARATE CONDUITS PREFERRED -COORDINATE W/MANUFACTURER NEMA 3R OR 4 JUNCTION BOX IF DESIRED OR REQUIRED BY CODE. MIN. 2' ABOVE GROUND (OPTIONAL) RISER COVER, EXTENSION AND FRAME PLASTIC IN NON -TRAFFIC SEAL OFF AREA CONCRETE RING/HEAVY FITTING IF JCT. DUTY FRAME AND COVER IF IN BOX UTILIZED TRAFFIC AREA (TYPICAL EACH TANK OUTLET) RISER WALL - 2" PVC SCH 40- SECURELY MOUNT LEVEL - SWITCH SUPPORT ROD TO WALL WITH STANDOFFS. FIRMLY ATTACH LEVEL SWITCHES TO ROD. 2000 GALLON PRECAST CONCRETE SEPTIC TANK (SEE DETAIL) TEE FITTING SCH 40 TANK COVER ALARM SOLENOID VALVE OPERATION THE CONTRACTOR SHALL LOCATE THE WATER SERVICE TO THE HOME, INSTALL A SOLENOID VALVE (FULL PIPE SIZE) FOLLOWING THE MAIN SHUTOFF VALVE AND WIRE THE SOLENOID VALVE TO THE LEVEL CONTROL PANEL VALVE TO NORMALLY OPEN AND POWERED TO CLOSE.. UPON A HOLDING TANK 2 HIGH LEVEL ALARM THE VALVE SHALL BE CLOSED. GENERAL NOTES 1. HOLDING TANKS TO BE FULLY WATERPROOF AND WATER TIGHT. 2. ALARM PANEL POWER SUPPLY TO BE RUN FROM CIRCUIT BREAKER PANEL IN BUILDING. EXTERIOR RUNS TO BE IN CONDUIT. PROVIDE CIRCUIT BREAKER SIZE AS RECOMMENDED BY MANUFACTURER. 3. CONTRACTOR IS TO INSPECT. THE EXISTING PANELBOARD. IF THE PANEL IS NOT GROUNDED PROVIDE 2-5/8"x8' GROUND RODS. CONNECT TO EXISTING WATER SERVICE. IF ANY OTHER ISSUES ARISE CONTACT ENGINEER PRIOR TO PERFORMING ANY FURTHER WORK. 4. ALL OPENINGS THROUGH THE CONCRETE TANKS ARE TO BE PROVIDED WITH LINK SEALS OR AN EQUAL PRODUCT TO PREVENT LEAKAGE INTO THE STORAGE TANKS. 5. ALL WORK TO CONFORM TO THE NATIONAL ELECTRIC CODE AND THE BUILDING CODE OF NYS. 6. ELECTRICAL WORK TO BE INSPECTED BY THE NYS BOARD OF FIRE UNDERWRITERS OR AN EQUIVALENT ORGANIZATION. 7. ALARM PANEL AND SCREENED VENT MAY BE INSTALLED ON THE BUILDING EXTERIOR IF DESIRED BY THE OWNER. 8. THE ATMOSPHERE IN THE HOLDING TANKS IS CONSIDERED TO BE A CLASS 1, GROUP D, DIVISION 1 RATED SPACE UNDER THE NATIONAL ELECTRIC CODE. THE CONTRACTOR SHALL PROVIDE THAT ALL WORK CONFORMS TO THE APPROPRIATE DETAILS FOR THIS CONSTRUCTION. THIS INCLUDES INSTALLING SEAL OFF FITTINGS ON ANY ELECTRICAL LINE THAT RUNS BETWEEN THE ALARM PANEL AND/OR OTHER ELECTRICAL PANELS, FILLING WITH THE APPROPRIATE SEALANT TO PREVENT GASSES FROM ENTERING THE ELECTRICAL PANELS. THEY ARE TO BE INSTALLED NO CLOSER THAN 18" FROM THE ELECTRICAL PANELS. 9. DO NOT INSTALL JUNCTION BOXES OR SPLICE WIRE INSIDE THE HOLDING TANKS. 10. A SOLENOID VALVE IS TO BE INSTALLED IN THE WATER SERVICE LINE TO THE HOME WHICH WILL BE NORMALLY OPEN. THE VALVE IS TO BE ENERGIZED BY THE TANK SHUTOFF LEVEL ALARM SWITCH. WHEN THE SWATCH IS REACHED THE SOLENOID VALVE SHALL BE CLOSED THEREBY CUTTING OFF THE WATER SUPPLY TO THE HOME. SOLENOID 'VALVE TO BE ASCO RED HAT MODEL 8221 OR EQUAL SIZE PER PIPE SIZE OF INCOMING WATER SERVICE. 11. THE CONTRACTOR TO TEST THE ALARM PANEL TO DETERMINE PROPER FLOAT SETTING LEVELS. IN ADDITION ALARM SYSTEMS ARE TO BE TESTED. ENGINEER TO WITNESS ALL TESTING. VARIANCE REQUEST-, WE ARE REQUESTING A VARIANCE TO REPLACE THE EXISTING ONSITE SEPTIC SYSTEM WITH A HOLDING TANK SYSTEM. NO VARIANCES ARE REQUESTED AFFECTING NEIGHBOR'S PROPERTY OR WELLS. THE PROPOSED SYSTEM MEETS ALL OF THE TOWN'S REQUIREMENT'S FOR A HOLDING TANK SYSTEM INCLUDING THE ALARM LEVEL CONTROL SYSTEM AS WELL AS THE WATER SERVICE SHUTDOWN CIRCUITRY. THIS SYSTEM IS PROPOSED DUE TO THE TOWN'S HESITATION TO APPROVE A PREVIOUSLY APPROVED ENHANCED TREATMENT ONSITE SEPTIC SYSTEM. `11.11all _ 00 WATER LEVEL 3" MIN. COARSE SAND, GRAVEL OR PEA GRAVEL SECTION VIEW INLET I 13'0" CONTRACTOR NOTIFICATION: THE CONTRACTOR SHALL CONTACT THE DESIGN ENGINEER PRIOR TO THE START OF CONSTRUCTION TO ENSURE COMPLETE UNDERSTANDING OF SYSTEM DESIGN INTENT. IF DIFFERING SITE CONDITIONS FROM THOSE PRESENTED IN THIS PLAN ARE ENCOUNTERED, THE CONTRACTOR SHALL CONTACT THE DESIGN ENGINEER IMMEDIATELY PRIOR TO ANY FURTHER WORK BEING COMPLETED. GARRY ROBINSON, P.E. PHONE: 518-796-4265 EMAIL: grobinsonpe®gmoil. com CONCRETE DEADMAN PALLETTE VERSATILE BLOCK SEE CHART FOR SIZE (TYP) STRAPPING OVER TOP OF TANK 2 REQUIRED HOLDING TANKS NOs. 1 & 2 PLAN VIEW J 34 3 37 __j TAK°DmEVME LANE 36 1 93 W 0 o W x 65 7.. A(C)LD SITE � Q J W l.7 1 A68B10 47 •J9 bt 62 63 y.� W TH LANE NORTH 87 30.1 � u 26 � 1.03 A<C) w Q 4.96 �a2 PERRY TREE LAZE 2. � 36 � S5 69 a 1 27 11 30 31 32 33 34 2P 70 3e 41 PINE TREE LAZE 03 71 29 20 S7 26 25 24 39 M � $< m>2 17 18 a9 20 21 22 23 39 35 37 CHESTNUT LANE 1.27 A(C) 16 as 13 11 SITE LOCATION MAP NOT TO SCALE POLY COVER do SAFETY FINAL GRADE SYSTEM MAINTENANCE NOTES -HOLDING TANK SY PAN (TYP. OF 2) IT IS IMPERATIVE THAT THE OWNER PROVIDE QUALITY MAINTENANCE FOR = THIS SYSTEM. SEND AS LITTLE GREASE AS POSSIBLE TO HOUSE DRAINS. STRAPPING OVER INLET � CONCRETE MONITOR HOLDING TANK LEVELS AND PUMP TANK SHORTLY AFTER THE SLOTTED TOP OF TANK HOLDING TANKS DEADMAN TANK HIGH LEVEL ALARM IS ENERGIZED. ENSURE THAT ALL FIXTURES IN 0­60-1 OPENING OUTLET 2 REQUIRED Nos. 1 & 2 THE HOME ARE LOW FLOW AND THAT EVERYONE THAT RESIDES THERE IS AWARE OF THE LIMITED CAPACITY OF THE HOLDING TANK SYSYTEM. AFTER A FEW MONTHS OF OPEARATION OF THE SYSTEM YOU SHOULD BECOME APPROX. 490 AWARE OF HOW WATER USE IMPACTS THE CAPACITY OF THE SYSTEM AND GAL/FOOT °U0"A"� 001"A0L °um HOW LONG IT TAKES TO FILL THE SYSTEM AT A POINT THAT IT TRIPS THE IWO OAS. OOM 2- jr ALARM. 2D00 0AL 00N_ 2' HAVE A SEPTIC PUMPING CONTRACTOR ON CALL AT ALL TIMES SO THAT HE CAN COME AND PROVIDE A PUMP OUT IN SHORT ORDER. HAVE THE PHONE INLET PUN VIEW NUMBER POSTED IN PLAIN SITE. ALSO HAVE THE NUMBERS OF A FEW ALTERNATE COMPANIES THAT WOULD BE AVAILABLE IF THE MAIN "j ,� : •- "; : y^._�.�• _ •!1: ti : "; i:,,i`; ; 4" ;C�+ CONTRACTOR IS UNAVAILABLE WHEN NEEDED. e� /� ` '`" `� +``'7"-�"•�"•'` �` FOLLOWING THESE SIMPLE GUIDELINES CAN GET YOU TO A POINT THAT YOU HOLDING TANK #2 DETAILS - 2000 GAL. ARE AWARE OF HOW MUCH YOU DISCHARGE TO THE HOLDING TANKS AND SECTION VIEW HOW LONG YOU HAVE UNTIL THE TANKS FILL AGAIN AFTER THEY ARE NOT TO SCALE PUMPED. WE RECOMMEND THAT EACH TIME YOU CALL THE CONTRACTOR THAT YOU HAVE BOTH TANKS PUMPED OUT IN THEIR ENTIRETY. YOU WILL BUOYANCY CONTROL SCHEMATIC QUICKLY LEARN THAT CONSERVING WATER IS VERY IMPORTANT IN THE OPERATION OF THIS HOLDING TANK SYSTEM AND THAT IT LOW WATER Scale: None USAGE WILL SAVE YOU CONSIDERABLE MONEY. IF THE SYSTEM SEEMS TO BE FILLING QUICKER THAN NORMAL YOU SHOULD 12-3" CHECKS THE TANKS AND THE PIPING TO ENSURE THAT THERE IS NO CLEAR WATER LEAKING INTO THE SYSTEM BY WAY OF DRIPPING FAUCETS, RUNNING TOILETS OR LEAKS INTO THE SYSTEM FROM OUTSIDE (AS GROUNDWATER IS INLET _TVERY HIGH ON THIS LOT). WATER LEVELAPPE:D OUTLE T HOLDING TANK SYSTEM NOTES: Go CD to 1.) THE LOT INFORMATION HAS BEEN TAKEN FROM WARREN COUNTY TAX MAPPING. INLET OUTLET TEES AS p _ THIS IS TOWN OF LAKE GEORGE TAX MAP NO. Z26.09-1-3. WELL AS EFFLUENT N 14 FILTERS NOT REQUIRED 2.) PROVIDE A SLWACE DRAINAGE SWALE AROUND THE HOLDING TANK SYS. TO GENERAL NOTES DIVERT SURFACE RUNOFF AWAY FROM THE SYST1EM. INSTALL NO CLOSER TF THE LEACH NG SYSTEM. 1. MSTALLATION TO BE FULLY WATERPROOF AND WATERTIGHT. HAN 25' FROM THE UPHILL EDGE O . A; :'+'"':�,•,^,•-�,�"f:vi`: ; ; �� 2. POWER SUPPLY TO BE RUN FROM CIRCUIT BREAKER PANEL IN THE • �' +� ^ '"'' '� °�.'� ,r "^'`��Y' �:a..��`ss.� 3.) OWNER SHALL NOT ALLOW ANY CLEAR WATER DISCHARGES SUCH AS SUMP PUMP HOME TO ALARM PANEL EXTERIOR RUN TO BE IN 3" MIN. COARSE SAND, GRAVEL OR PEA GRAVEL OR ROOF DRAINS TO BE DIRECTED TO THE HOLDING TANK SYSTEM. CONDUT. PROVIDE CIRCUIT BREAKER SIZE AT CS PANEL. AS RECOMMENDED BY MANUFACTURER. MAKE MODIFICATIONS REQUIRED SECTION VIEW 4.) CONTRACTOR TO SECURE ALL REQUIRED PERMITS FOR PROJECT. AT EXISTING PANEL. TO MEET NEC. INLET 5.) CONTRACTOR RESPONSIBLE FOR COMPLJANCE WITH ALL OSHA REGULATIONS 3. ALL WORK TO CONFORM TO NATIONAL ELECTRIC CODE ALL ELECTRICAL WORK TO BE INSPECTED BY A NYS APPROVED 13'0" AND REQUIREMENTS. INSPECTION COMPANY. 6.) ALL WORK MUST CONFORM TO ALL FEDERAL, STATE AND LOCAL CODES, 4. CONTRACTOR TO SECURE ALL REQIMRED PERMITS FOR PROJECT. SPECIFICATIONS, ORDINANCES, RULES AND REGULATIONS. 5. CONTRACTOR RESPONSIBLE FOR COMPLIANCE WITH ALL OSHA REGULATIONS AND REQUItEMENTS. 7.) ALL UTILITY LOCATIONS, IF SHOWN, ARE APPROXIMATE. CONTRACTOR TO 6. ALL WORK MUST CONFORM TO ALL FEDERAL. STATE AND LOCAL POLY COVER & SAFETY FIELD VERIFY AND CONTACT DIG SAFELY NEW YORK AS REQUIRED AT 811. DES, SPECIFICATIONS. ORDINANCES. RULES AND REGULATIONS. 8.) CONTRACTOR TO PROVIDE RECORD DRAWINGS FOR THE HOLDING TANK SYS. 7. ALL UTILITY LOCATIONS. F SHOWN. ARE APPROXIMATE CONTRACTOR PAN (TYP. OF 2) DISPOSAL SYSTEM TO THE TOWN OF QUEENSBURY CODE ENFORCEMENT DEPT. TO FIELD VERIFY AND CONTACT DIG SAFELY NY AS REQUIRED. 8, CONTRACTOR TO PROVIDE READ DRAWINGS FOR THE WORK INLET SLOTTED CAPP 9.) THERE ARE NO KNOWN WATER SUPPLY WELLS WITHIN 50 FEET 9. ALL REFUSE. DEBRIS AND MISC. ITEMS TO BE REMOVED SHALL BE APPROX. 490LEGALLY DISPOSED OF OFF SITE BY THE GENERAL CONTRACTOR. GAL/FOOT OPENING OUST OF THE PROPOSED HOLDING TANK SYS. 10. ALL POINTS OF CONSTRUCTION INGRESS OR EGRESS SHALL BE SEE DETAIL FOR LEVEL 10.) ALL REFUSE, ITEBPoS AND MM ITEMS TO BE REWOVU SHALL BE LEGALLY MAINTAINED TO PREVENT TRACKING OR FLAWING OF SEDIMENT OR DISPOSED OF OFF SITE BY THE GENERAL CONTRACTOFL DEBRIS ONTO A PUBLIC ROAD. ALARM SYSTEM 0 11.) ALL POINTS OF CONSTRUCTION WRESS OR EGRESS SHALL BE MAINTAIINED TO 11. TANKS TO BE PLACED IN SERIES WITH THE 1500 GALLON TANK PREVENT TRACKING OR FLOWING OF SEDA"T OR DEBRIS ONTO A PUBLIC ROAD TO BE FIRST IN THE FLAW PATH. LOCATE ADJACENT WHERE OR ON THE PAVED AREAS OF THE STE. SHOWN ON THE PLAN. BOUENCY CONTROL TO BE PLACED IMMEDIATELY TO PREVENT FLOTATION OF EMPTY TANKS. 12.) GRAVITY PIPING TO BE PVC sDR-33 OR scs-40. 12. HOMEOWNER AND/OR CONTRACTOR TO SECURE PROPER INLET PLAN VIEW 13.) CONTRACTOR TO FOLLOW EROSION CONTROL GU CANES FOR ALL WORK AS PROVIDED INSURANCES AND PERMITS PRIOR TO THE START OF CONSTRUCTION. SYSTEM IS FULLY T 13. THE EXISTING SEPTIC SYSTEM IS TO BE LEFT IN PLACE UNTIL. SUCH FOR IN "NEWT FOR lURBANERC5i0N AMSFDIAElT CONTROL DATED TIME THE HOLDING TANK EST & OP APRIL ED ERATIONAL HOLDING TANK #1 DETAILS-2000 GAL. '�7 °R ITS ITS MOST CURRENT UPDATE 14. THE CONTRACTOR IS TO COMPLY WITH THE REQIAREMENTS LISTED IN 14.) A PROFESSIONAL ENGINIEER SHALL PERFORM IWSPECTKkfS OF THE SYSTEM AT THE TOWN CODE SECTION 136-11 hOLDING TANKS WITH ONE EXCEPTION: NOT TO SCALE FOLLOWING TIMES: HOLDING TALCS OPEN, W/P P"ES IDPO6ED. THERE ARE TO BE ,NO WIRING dANCTION BOXES INSTALLED ED WITHMI 48 HOUR NOTICE REOLW D. ENG04EER TO CERTIIY THAT THE SYSTEM WAS THE INTERIOR OF THE HOLDING TALCS ALL WIRING CONNECTIONS INSTALLED IN SUBSTANTIAL ACCORCANCE W/VLANS. A FEE IS REQUIRED ARE TO BE MADE IN NEMA 3R OR 4X JUNCTION BOXES ABOVE HOLDING TANK NOTES: FOR THIS SERVICE. THIS DOES NOT CONS71TUTE FULL TIME INSPECTION OR PROJECT GROUND AS SHOWN. 1. HOLDING TANKS TO BE PALLETTE OR EQUAL. SUPERVISION. THESE SERIACES CAN BE PROBED AT A00IT"AL COSTS. � I��l b,' TANK TO PREFERABLY BE SEAMLESS IF 15.) THE CONTRACTOR SHALL LOCATE THE WATER SERVKE TO THE HOME, INSTALL A NOT PROVIDE SECURE WATERPROOF JOINTS. SOLENOID VALVE (FULL PIPE SIZE) FOLLO" N THE MAIN SHUTOFF VALVE AND F L ( t 2. PROVIDE 6*-12* OF COVER OVER TANK. PROVIDE WIRE THE SOLENOID VALVE TO THE PUMP STATION CONTROL PANEL. VALVE TO w BE POWERED OPEN AND UPON POW EL LOSS OR A PUMP STATION HIGH LEVEL EXTENSION COLLAR IF COVER OVER TANK EXCEEDS 12 . ALARM THE VALVE SHALL BE CLOSED. 3. PROVIDE MIN. 3" PEA STONE, COARSE SAND OR GRAVEL T(' '` -Y � BASE UNDER SEPTIC TANK. E 4. WHERE SEASONAL HIGH GROUNDWATER (SHGW) CAN RISE ABOVE THE TANK BASE, ANCHOR AGAINST FLOTATION AND DO NOT PUMP DURING SHGW PERIOD. TOWN OF OU RY BUILDING n PT. Reviewed v° 6.19-1-60 SEP-0538-2022 pant, Sean Date: 2 North Ln Septic Variance/ Iteration Lands of Sean Chant 22 North Lane - Assembly Point A001'0.0� R. Ro •Q TOWN OF QUEENSBURY COUNTY OF WARREN STATE OF NEW YORK HOLDING TANKS - SITE PLAN & DETAILS HOLDING TANK NO. 2 SCHEMATIC SECTION AND INSTALLATION NOTES NOT TO SCALE •'`�"' DATE: 6-8-23 SCALE: AS NOTED 1 12-12-23 ADDED CAPACITY TO HOLDING TANK SYSTEM GARRY ROBINSON, P.E. NYSPE: #60166 REV. IDATE: NOTE: CONSULTING ENGINEER DWG. NO.: schontholdingtonk SHEET 1 OF 1