Loading...
SOLAR-0864-2021 Office Use Only � 4 Permit#: i �,. Permit Fee:$ 742 Bay Road,Queensbury,NY 12804 P:518-761-8256 www.gueensbury.net Invoice#: Flood Zone? Y /N Reviewed By: SOLAR PANEL PERMIT APPLICATION SITE INFORMATION: Project Location: 185 Chestnut Ridge Rd,Queensbury, NY, 12804 Tax Map ID#: 290.-1-22.3 . Subdivision Name: N/A PROJECT INFORMATION: Residential: Commercial Other: X Single Family Multi-Family Are the solar panels? X. Purchased Leased Estimated cost of construction:$ 32,000 Total System Capacity Rating (sum of all panels): D E C E 0 Solar PV System: 12.16 kW DC DEC 0 6 2021 Select System Configuration: T URY x Supply side connection with micro inverters BUILDING&CODES Supply side connection-with DC optimizers Supply side connection with string inverter Load side connection with DC optimizers Load side connection with micro inverters Load side connection with string inverter Solar Panel Application Revised January 2021 i DECLARATION: .- 1. 1 acknowledge that no construction shall be commenced prior to the issuance of.a valid permit and will be completed within a 12 month period.Any changes to the approved plans prior to/during construction will require the submittal of amended plans,additional reviews and re-approval. 2. If,for any reason,the building permit application is withdrawn, 30%of the fee is retained by the Town of Queensbury.After 1 year from the initial application date, 100%of the fee is retained. 3. Ifthework is not completed by the 1 year expiration date the permit may be, renewed, subject to fees and department approval. 4. 1 certify that the application, plans and supporting materials are a true and a complete statement and/or description of the work proposed,that all work will be performed in accordance with the NYS Building Codes,local building laws and ordinances, and in conformance with local zoning regulations. 5. A third-party electrical inspection will be completed at which time the Town of Queensbury's Building and Codes Enforcement department will be contacted to complete an inspection of the final installation of the solar panels. Please sign below to affirm that all answers are correct and that you have met all of the conditions and requirements to submit a unified solar permit. I have read and agree to the above: Please see attached authorization form 11/15/2021 Homeowner's Signature Date .a 11/15/2021 S.olar:Co. Rep esentative Signature Date .I U Solar Panel Application Revised January 2021 DocuSign Envelope ID:76624CF1-OED6-42C5-AA23-F7BBOF69E774 9/23/2021 Dear SunCommon, I hereby authorize you to apply for a building permit on my behalf, for the purpose of installing a solar electric and or battery.system at my property located at: 185 Chestnut Ridge Road Queensbury, NY 12804 DocuSigned by: ""�� Property Owner Signature 'r� (,c.o4 Date: 9/23/2021 CE75317181837481E Property Owner Name: Richard Leach pE E DEC 0 6 2021 TOWN OF QUEENSBURY BUILDING&CODES CONTACT INFORMATION: PLEASE PRINT LEGIBLY OR TYPE, PLEASE INCLUDE AN EMAIL • Property Owner(s): Name(s): Richard Leach Mailing Address; C/S/Z: -185 Chestnut Ridge Rd, Queensbury, NY, 12804 Cell Phone: _( 518 .) 926-9936 Land Line: Email: leachpad@gmail.com- • Solar Contractor: 1 .. Workers' Comp documentation must be submitted with this.application. Business Name: SunCommon Contact Name: Grayson Ball Mailing Address, C/S/Z: 11.55 Flatbush Ave, Kingston, NY,12401 Cell Phone:_( 845 ) 475-4515 Land Line:_( ) Email: rbk.rpm c suncommon:com- • Electrical Contractor: Workers' Comp documentation must be submitted with this application Business Name: SunCommon . Contact Name: Grayson Ball Mailing Address,C/S/Z: 1155 Flatbush Ave, Kingston, NY,12401 Cell Phone:_( 845 ) 475-4515 Land Line: _( ) Email: rbk rpm a(7suncommon.com Contact Person for Compliance in Yegards to this project: Grayson Ball Cell Phone: 845 ) 475-4515 Land Line: ( ) Email:. rbk.rpm@suncommon.com Solar Panel Application Revised January 2021 l PLEASE INCLUDE WITH YOUR SUBMITTAL: 1. Completed Solar Panel Installation permit application THREE (3) COPIES OF THE FOLLOWING: 2. Signed and stamped architect or engineer solar plans, which include: a. Design/snow load b. Letter indicating rafters can handle additional load of solar panels and snow c. Proper setbacks from ridgeline for Fire Department access d. Rapid.Shutdown 3.. Plot plan indicating proposed structure to hold solar panels ADDITIONAL IMPORTANT INFORMATION: 1. Any changes to the approved plans prior to or during construction will require the submittal of .amended plans, additional reviews and re-approval: 2. If, for any reason, the building permit application is withdrawn, 30% of the fee is retained by the Town of Queensbury. After 1 year from the initial application date, 100%of the fee is retained. Solar Panel Application Revised January 2021 DocuSlgn Envelope ID:76624CF1-OED6-42C5-AA23-F7BBOF69E774 9/23/2021 Dear SunCommon, I hereby authorize you to apply for a building permit on my behalf, for the purpose of installing a solar electric and or battery system at my property located at: 185 Chestnut Ridge Road Queensbury, NY 12804 D = DEC 0 b 2021 TOWN OF QUEENSBUR. BUILDING & CO- D -�- ocuSigned by: ""�� Property Owner SignatureCAE7531718183748E �A4 (,A& Date: 9/23/2021 . Property Owner Name: Richard Leach WESTSHORE W_j, DESIGN ENGINEERS 100 GREAT OAKS BLVD. I SUITE 117A ALBANY NEW YORK -12203 To: SunCommon DE C E 0 V 13 Hook Road Rhinebeck,NY 12572 DEC 0 6 2021 Date: October 4, 2021 TOWN OF QUEENSBURY Ref.: 21100037 BUILDING&CODES Subject: Leach Residence 185 Chestnut Ridge Rd. Queensbury,NY To Whom It May Concern, The following references-the structural roof analysis:of the Leach .residence located in Queensbury, NY. Westshore Design Engineers has been retained in order to analyze the existing roof structure for adequacy in supporting the proposed additional loading due to rooftop solar panels. . The site-specific loadings are as follows: Seismic Design Category B; basic Wind Speed bf 115mph; and:Ground Snow Load of 50psf, per ASCE 7-10. The existing roofs consist of 2x12 at 16"o.c. with a 14'-6" span. Based on structural analysis, it has been determined that the RI and R2 roofs are adequate to support rooftop solar panels with a maximum loading of 3psf. The panel layout is not restricted within the specified portions of roof. "Snap X Rack"L- foot anchors with 5/16" diameter lags required at 48" on center maximum with 2.5" minimum embed or racking system of equal or greater design values. Please don't hesitate to contact us with additional requests. 0 F N E AS A. ` Thank you. �P `o� N j� O Co �~ -P* Westshore Design Engineers XP. 07/24 r � W D -091373 A�POFE S S I ON�'� 10/4/2021 John Eibert Nicolas Nitti,P.E. Project Coordinator President WestShore Design Engineers 100 Great Oaks Blvd. V Suite 117A V Albany,NY 12203 V 518.313.7153 Data Sheet Enphase Microinverters Region:AMERICAS En haSe The high-powered smart grid-ready Enphase IQ 7 Micro' and Enphase IQ 7+ MicroTm IQ 7 and IQ 7+ dramatically simplify the installation process while . . achieving the highest system efficiency. M. ICrOinverters Part of the Enphase IQ System,the IQ 7 and IQ 7+ Microinverters integrate with the Enphase IQ Envoy', Enphase IQ Battery", and the Enphase' DE C E 0 V E EnlightenTm monitoring and analysis software. IQ Series Microinverters extend the reliability DEC 0 6 m, standards set forth by previous generations and TOWN OF QUEENSBURY undergo over a million hours of power-on testing, BUILDING&CODES enabling Enphase to provide an industry-leading warranty of up to 25 years. Easy to Install • Lightweight and simple • Faster installation with improved,lighter two-wire cabling • Built-in rapid shutdown compliant(NEC 2014&2017) Productive and Reliable • Optimized for high powered 60-cell and 72-cell*modules • More than a million hours of testing • Class II double-insulated enclosure • UL listed 0 • Smart Grid Ready • Complies with advanced grid support,voltage and { frequency ride-through requirements _ Remotely updates to respond to changing grid requirements • Configurable for varying grid profiles • Meets CA Rule 21 (UL 1741-SA) *The IQ 7+Micro is required to support 72-cell modules. U� To learn more about Enphase offerings,visit enphase.com ENPHASE. LG N -ONO2 LG380N1_t A6 --- - 380W The LG NeON°2 is LG's best selling solar module and one of the most powerful and versatile modules on the market today.The cells are designed to appear all-black at a distance,and the performance warranty guarantees 90.6%of labeled power output at 25 years. --- e C US - Made'iri"� - 1 USAWARRANTY r• `� - . . Features Enhanced Performance Wartanty 25 Year Limited Product Warranty zsYrS isn' LG NeON°2 has an enhanced The NeON°2 is covered by a 25-year limited performance warranty.After 25 product warranty.In addition,up to$450 of years,LG NeON°2 is guaranteed at labor costs will be covered in the rare case that least 90.6%of initial performance. a module needs to be repaired or replaced. Solid Performance on Hot Days + Roof Aesthetics ®; LG NeON°2 performs well on hot days = LG NeON°2 has been-designed with due to its low temperature coefficient. aesthetics in mind using thinner wires that appear all black at a distance. When you go solar, ask for the brand you can trust: LG Solar About LG Electronics USA,Inc. �� LG Electronics is a global leader in electronic products in the clean energy markets by offering solar PV panels and energy storage systems The company First embarked on a solar energy source research program in 1985,supported by LG Group's vast experience in the semi-conductor,LCD,chemistry and materials industries.In 2010,LG Solar successfully released its first MonoXa series to the market,which is now available in 32 countries.The NeONa(previous MonoX©NeON),NeON®2,NeON52 BiFacial won the"Intersolar AWARD"in 2013,2015 and 2016,which demonstrates LG's leadership and innovation in the solar industry. Life's Good LG NeON®2 LG380N1C-A6 General Data Electr[cal Properties(STC*) Cell Properties(Material/Type) Monocrystalline/N-type Model-- L3380N1C-A6 I Cell Maker. LG I Maximum Power(Pmax) [W] 380. Cell Configuration - 60.Cells(6 x 10) I MPP Voltage(Vmpp) [V] 35.7 Module Dimensions(Lx W x H) 1,740mm x 1,042mm x 40mm -MPP Current(Impp) [A] - 10.65 Weight. 18.6 kg - I Open Circuit Voltage(Voc,t 5%) [V] 41.9 _ Glass(Material) .Tempered Glass with AR Coating Short Circuit Current(Isc t 591) [A] 11.39 Backs_heet(Color) - White. Module Efficiency [%] 21.0 _ Frame(Material) - i Anodized Aluminium [Bifaciality Coefficient of Power - [%] 10 Junction Box(Protection Degree) IP 68 with 3 Bypass Diodes Power Tolerance [%] 0- 3 Cables(Length) - 1,100mm x 2EA - *STC(Standard Test Condition):Irradiance 1000 W/m',cell temperature 25°C,AM 1.5 Connector(Type/Maker) I MC 4/MC Operating Conditions Cerifieatioos'and Warranty ,IoperatingTemperature [°C] 40-+85 IEC61 21 5-1/-1-1/2:2016,IEC61730-1/2s2016; IMaximumSystemVoltage [V] 1,000 UL61730r1:2017,UL61730-2-:2017 - Certifications _ Maximum Series Fuse Rating [A] 20 .- -ISO 9001,ISO 14001,ISO 50001 OHSA518001 'Mechanical TestLoad'(Front),- : .I[Pa/psf],I - 5,400, - Mechanical Test Load'(Reaar) [Pa/psf] . _ -� 4,000 Salt Mist Corrosion Test IEC 61701:2012 Severity 6 -Based on IEC 61215-2:2016(Test Load-Design Load x Safety Factor(1.5)) , Ammonia Corrosion Test -IEC 62716:2013 Mechanical Test Loads 6,000Pa/5,40OPa based on IEC 61215:2005 Module Fire Performance ..Type 1(UL 61730) I Fire Rating ..Class C(UL-790,11LC/ORD C 1703) Packaging Configuration Soler Module Pmduct Warranty 25 Year Limited I'Numberbf Modules per Pallet [EA) 25 Solar Module Output Warranty Linear Warranty* Number of Modules per 40'Container [EA],' - 650'Improved:to year 98.5%,from 2-24th year.0.33%/year down,90.6%at year 25 - = Number of Modules per 53'Container [EA] 850 Packaging Box Dimensions(L x W x H) [mm] 1,790 x 1,120 x,1,213 Temperature Characterlstia - I Packaging Box Dimensions(Lx W x H) [in]. -70.5 x 44.1 x 47.6 I NMOT* ' - - [°C]- 42 t 3 - I packaging Box Gross Weight. [kg] 500 ' I Pmax - [9✓°C] 0:34 I Packaging Box Gross Weight [lb] : 1,102 'Voc [%/°C] -6.26 Isc [%/°C] 0,03 . . •NMOT(Nominal Module Operating Temperature).Irradiance 800 W/m',Ambient temperature 20°c, Dimensions(mm/inch) Wind speed 1 m/s,Spectrum AM 1.5 - 1042D/41.0(6¢e of 6bort side) Electrical Pro erties NMO l 1 GO2.0/39A(Distance between Ground"og 8 Mounting Holes) Model LG380N1C-A6 - 40.0/1.67 IMaximum Power(Pmax) .[W] � 285 17SO'l 6.9-' - � ; . - IMPPVoltage(Vmpp) [V] 16-B.0 x3.0/03 x0.1 - 33.5 Drain Hales - jMPPCurrent(Impp) [A] - 8A9 - - B-043101 (-) (+)lunvion Baz Grounding Holes - '�Open Circuit Voltage(Voc) IV] - 36A . e-95x�120/0.3x05 'Short Circuit Current(Isc) - [A] 9.16 - Moan Hales 1.VCUrves 1100/43.3 Cable Length- § 12.0 100ow 9 . 10.0 _ BOW 8.0 .600W 4 6.0 .. ` 400W- 4.0 r . . 20OW 2.0 - - - 0.0 a 6.0 5.0 -10.0 15.0 20.0 25.0 30.0 35.0 46.0 45.0 Voitagem - J 1\ LG Electronics USA,Inc. Product specifications are subject to change without notice. LGSolar Business Division LG38ONlC-A6-AUS.pdf 2000 Millbr0ok Drive 012221 Lincolnshire,IL 60069 Lifes Good www.ig-sbiarcom ©2021 LG Electronics USA,Inc.All rights reserved. Enphase IQ 7 and IQ 7+ Microinverters INPUT DATA(DC) IQ7-60-2-US/IQ7-60-B-US , IQ7PLUS-72-2-US/IQ7PLUS-72=B-US C_ommonly,used module pairings' _ 235 W-350-W+ 235 W-440 W+ Module compatibility- -- - 60-cell PV modules only � -60-cell and 72-cell PV modules - Maximum input DC-Voltage, 48 V _ 60 V _ Peak power tracking voltage 27 V-37 V -' 27 V-45 V Operating range 16'V 48 V 16V, 60 V Min/Max start voltage--�-----__---�- 22 V/48 V -----..___-----_-- 22 V/60 V �---- ---- /, ---- ----� Max DC short circuit current(module Isc) 15 A -- -_.- -= 15 A ! _-77 ---_---- Qvervoltage class DC port II- II CDC port,backfeed current PV array configuration. 1 x-1 ungrounded array;No additional DC side protection required;- AC side protection requires max 20Aipdr branch circuit- OUTPUT DATA(AC) r IQ 7 Microinverter. IQ7+Microinverter " Peak output power. ;---- 250 VA - - "- - - 295 VA Maximum continuous output power 240 VA 290 VA " ffNominal(L L)voltage/range2 ---- - ---240 V_7- - 208 V - 211-264.V 183-229 V _ 211-264 V 183-229.V Maximum continuous output current 1.0 A(240 V) 1.16 A(208 V)- 1.21 A(240 V) 1.39 A(208 V)' [Nominal frequency 60 H2 60 Hz - Extended frequency range 47-68 Hz 47-68 Hz AC short circuit fault c -.nf over 3 cycles 5.8 Arms,_ _ 5.8 Arms Maximum units per 20 A(L L)branch circuit3 16(240 VAC) 13(208 VAC) -13(240 VAC) 11 (208 VAC) Overvoltage class AG port III ° AC"port backfeed current 0 A 0,A Power factor setting _ _1.0 __ 1.0 Power factor(adjustable) 0.85 leading..0.85 lagging 0.85 leading...0.85 lagging EFFICIENCY @240 V @208-V @240 V @208 V L Peakefficiency 97:6%- 97.6% " '97.5% 97.3 CEC weighted efficiency - 9 7.0% 97.0% 97.0°(° 97.0 MECHANICAL DATA I"Ambient temperature range -40°C to+65°C• Relative humidity range 4%to 100%_(condensing) �onnectortype(IQ7-60 2_US&IQ7PLUS 72-2-US).MC4(or Amplienol H4_UTX with additional Q D_CC-5 adapter): Connector type(IQ7-60=13-US&IQ7PLUS-72-13-US) Friends PV2(MC4 intermateable)- Adaptors for modules with MC4 or UTX connectors: PV2 to MC4:order ECA-S20-S22 _ PV2 to UTX:order ECA-S20-S25 Dimes-sions(WxNx_1 -'- - - "-- - 212 min x 175 min x 30.2 mm:(with out,bracket) - --- - �_ - Weight" 1.08 kg(2.38 Ibs) Cooling Natural convection-No fans' Approved for wet locations Yes -- - --- - - - - -- -- - -- fPollution- - degree- : PD3 Enclosure Class II double-insulated,corrosion resistant polymeric enclosure j Environmental category/UV'exposure rating NEM-A Type 6/outdoor. FEATURES Communication Power•Line Communication(PLC) .. ` Monitoring Enlighten Manager and MyEnlighten monitoring options Both options require installation of an Enphase IQ Envoy, i.Disconnecting means' The AC and DC connectors have been evaluated and approved by UL for use.as the load-break . disconnectrequired by NEC 690. Compliance CA Rule 21 (UL 1741-SA) UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES=0003 Class B, CAN/CSA-C22.2 NO.107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according manufacturer's instructions. 1.No enforced DC/AC ratio.See the compatibility calculator at https7//enphase.com/­en-us/­support/module-compatibft. 2.Nominal voltage range can be extended beyond nominal if required,by the utility. 3.Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. To learn more about Enphase offerings,visit enphase.com &EN PICAS Es @ 2018 Enphase Energy.All rights reserved.All trademarks or brands used are the property of Enphase Energy,Inc. 2018-11-19