Loading...
RC-0577-2021 I 1 Office Use Only PRINCIPLE STRUCTURE PERMIT APPLICATION Permit#:_�- —'O�'�' ' 24Z� Permit Fee:$ �b��'• �� Town of Quccnsbury 2 tp��'.• 742 Bay Road, Queensbury, NY 12804 *Rec Fee: $ P: 518-761-8256 www.queensburynet Invoice#: Flood Zone? Y N Reviewed By: Project Location: 3 PO Ile IJ0 Lpp— C,ave_ens Tax Map #: a3q I'Z-2 Subdivision Name: / *RECREATION FEE$1000.00 for new dwelling units: single family, duplexes/two-family, multiplefamily, apartments,condominiums, townhouses,cr NYS Building Standards & Co ed manufactured home. This is in addition to the permit fee(s). D Il PROJECT INFORMATION: AUG 04 2021 Residential ❑ Commercial, Proposed Use: B�,LO NGUEENSBURY a CODES ❑ Single-Family: ❑Two-Family ❑ Multi-Family (#of units: ) 1. custom 2. ❑Modular(REQUIRED:NYS stamped engineered drawings of foundation plans) ❑Townhouse ❑ Garage (#of cars ) ❑ Business Office ❑ Retail ❑ Hotel/Motel ❑ Industrial ❑ Heated Warehouse/Storage Building ❑ Unheated Warehouse/Storage Building ❑ Amusement Ride ❑ Other (describe: ) MAIN STRUCTURE SQUARE FOOTAGE: GARAGE SQUARE FOOTAGE: 1ST floor: 1ST floor: J 2nd floor: 2"d floor: 3rd floor: Total square feet: Basement(habitable space): C(Q�Ltw Total square feet: ?A CW Principle Structure Packet Revised March 2021 J l , L ADDITIONAL PROJECT INFORMATION: 1. Estimated Cost of Construction: $ J o, 40 a 2. Proposed use of the building:,Usk `dies" de g C-e- 3. If Commercial or Industrial, indicate the name of the business: N n` 4. Source of Heat: _Gas _Oil /%Propane _Solar _Other: (Fireplaces need a separate Fuel Burning Appliances &Chimney Application, one per appliance) 5. Are there any structures not shown on the plot plan?_YES 1KNO Explain, if yes: 6. Are there any easements on the property?_YES NO 7. SITE INFORMATION: a. What is the dimensions or acreage of the parcel? 66 469,e- s b. Is this a corner lot? _YES _XNO c. Will the grade be changed as a result of the construction? X YES NO d. What is the water source? _PUBLIC ,PRIVATE WELL e. What type of wastewater system is on the parcel? _SEWER [PRIVATE SEPTIC DECLARATION: 1. 1 acknowledge that no construction shall be commenced prior to the issuance of a valid permit and will be completed within a 12 month period.Any changes to the approved plans prior to/during construction will require the submittal of amended plans,additional reviews and re-approval. 2. If,for any reason,the building permit application is withdrawn,30%of the fee is retained by the Town of Queensbury.After 1 year from the initial application date, 100%of the fee is retained. 3. 1 certify that the application, plans and supporting materials are a true and complete statement and/or description of the work proposed, that all work will be performed in accordance with the NYS Building Codes,local building laws and ordinances, and in conformance with localzoning regulations. 4. 1 acknowledge that prior to occupying the facilities proposed I, or my agents, will obtain a certificate of occupancy. 5. 1 also understand that I/we are required to provide an as-built survey by a NYSlicensed land surveyor of all newly constructed facilities prior to issuance of certificate of occupancy. I have read and agree to the above: PRINT NAME: 0 (1 S SIGNATURE: ()) 0) ) DATE: Principle Structure Packet Revised December 2020 CONTACT INFORMATION: PLEASE PRINT LEGIBLY OR TYPE, PLEASE INCLUDE AN EMAIL • Applicant: Name(s): Mailing Address, C/S/Z: IU� /21/ Cell Phone: S- K Land Line: � ) Email: ff)oPKZ) a, kP e cow Ca,�rle 42 o Lce1-1r• c2vt • Primary Owner(s): Name(s): Mailing Address, C/S/Z: Cell Phone: Land Line: �) Email: ❑ Check if all work will be performed by property owner only • Contractor(s): (List all additional contractors on the back of this form) Contractor Name(s): C_L an 'c-c�.1.0 f X.Caue�o n 1ne . _ Contractor Trade: S'�{r_ l,.►c�2� X(+��r�� ,'o.� Mailing Address, C/S/Z: (.9 3 w6 06 C (ttv- -A( L&,kx_ Geoiz-c �J`J Q q S Cell Phone: K K ) 4--t'0- 5-(s a 4 Land Line: Email: "Workers' Comp documentation must be submitted with this application" • Arch itect(s)IEngineer(s): Business Name: ISO,U.,e 0-- + Contact Name(s): Mt cl,r,&Z I u c.(�- Mailing Address, C/S/Z: S -L" ya. Sar�'�C f JV w Cell Phone: S 1 ) S R - r,43 2 Land Line: Email: rvi-�t c c bc�l�e2�h�c(L co►-v, Contact Person for Compliance in regards to this project: Aa Cell Phone: ( 51$ ) �'� S ��r�q Land Line: Email: Principle Structure Packet Revised December 2020 • Contractor(s): Workers' Comp documentation must be submitted with this application Contact Name(s): /V().-I CA &IAU 1p. ,& ` Eosj S,t,,PQ-t Contractor Trade: Mailing Address.,.C/S/Z: I .��� �-! �,2;c/t_ sOLc - (1- /o ral r.r , N�� a 6 3 Cell Phone: _(S�) - 2 Land Line: _(i) Email: y (Z : n+F. cog,a-s i C o�►-� • Contractor(s): WorkersXCp"documentation must be submitted with this application Contact Name(s): LC �O Contractor Trade: Mailing Address, C/S/Z: Cell Phone: Land Line: �) Email: Contractor(s): Workers' Co documentationInust be submitted with this application Contact Name(s): ;zc Contractor Trade: Pl&tm i C Mailing Address, C/S/Z: Cell Phone:_ Land.Line: Email- • Contractor(s): Workers' Comp documentation must be submitted with this application Contact Name(s): GZe� Contractor Trade: Mailing Address, C/S/Z: ( U-S 14 (1- Nq (2R:d S Cell Phone: Land Line: Email: • Contractor(s): Workers' Comp documentation must be submitted with this application Contact Name(s): - A'/C&_Z, In _ Contractor Trader t Mailing Address, C/S/Z: 14 .n 1,2-66r. Cell Phone: .. ( S1 g )^`�(O.SJ- .SC�1 Land Line: ( . ) Email: MOP 0 CA Lsc �:�In I r(g- Principle Structure Packet Revised December 2020 CHECKLIST--SINGLE FAMILY Project Location: REQUIRED-2 SETS 1. Building Permit application, completed YES NO N/A 2. Energy Code inspector's report from ResCheck, completed &signed X 3. Septic alteration application, if applicable 4. Solid fuel burning or gas insert appliance form(s), if applicable 5. Driveway permit, if applicable 6. Structural drawings, including: a. Floor plans b. Foundation plans c. Cross sections d. Elevations e. Window& door schedule f. Natural light, ventilation & emergency egress 7. Plot plan: showing proposed structure(s)with setback dimensions from all surveyed property lines 8. Electrical inspection agency selected VA CHECKLIST-- MULTI-DWELLING/COMMERCIAL Project Location: REQUIRED-2 SETS 1. Building Permit application, completed YES NO N/A 2. Energy Code inspector's report from ComCheck, completed & signed 3. Septic alteration application, if applicable 4. Solid fuel burning or gas insert appliance form(s), if applicable 5. Driveway permit, if applicable 6. Structural drawings, including: a. Floor plans b. Foundation plans c. Cross sections d. Elevations e. Design loads including floor, snow&wind load f. Seismic design g. Plans signed and sealed by registered architect or engineer h. Window& door schedule 7. Plot plan: showing proposed structure(s)with setback dimensions from all surveyed property lines 8. Electrical inspection agency selected 9. FINAL AS-BUILT PLANS SUBMITTED ELECTRONICALLY Principle Structure Packet Revised December 2020 r f ♦ 0 d �^ Office Use Only Permit#: Town of Queensbury Permit Fee:$ 742 Bay Road,Queensbury, NY 12804 P:518-761-8256 www.ciueensbury.net Invoice#: FUEL BURNING APPLIANCE & CHIMNEY APPLICATION **ONE APPLICATION PER APPLIANCE** Project Location: 171 P01 UQ.— Tax Map ID#: �3 Room of Install: r` �� 0n7 Planned Install Date: FUEL BURNING APPLIANCE INFORMATION: TYPE OF DEVICE: X _Stove _Fireplace Insert `Fireplace _Fuel Fired Equipment (Garage Only, 18" clearance per IMC 304.3) _Fireplace,factory built** (**Manufacturer's name: Model #: ) SOURCE OF HEAT: _Wood _Coal _Pellet Gas CHIMNEY INFORMATION: Masonry(require plans to be submitted): _block _brick Istone Flue: the _steel _size,in inches _Material*: double-wall _triple-wall _insulated (*Manufacturer's name: k RV00 Model#: ) 7-AVO Principle Structure Packet ' Revised December 2020 CONTACT INFORMATION: PLEASE PRINT LEGIBLY OR TYPE, PLEASE INCLUDE AN EMAIL ❑ Check if all work will be performed by property owner only • Installer/Builder: Workers'Comp documentation must be submitted with this application Contact Name(s): Contractor Trade: Mailing Address, C/S/Z: Cell Phone:_( ) Land Line: _( ) Email: Contact Person for any questions regarding this project: Cell Phone:�_) Land Line: Email: ADDITIONAL INFORMATION: 1. Two (2) inspections are required. A rough-in inspection, prior to installation and a final inspection, after installation. 2. Manufacturer's installation manual must be available at the time of inspection. 3. Masonry fireplaces&chimneys require plans to be submitted. 4. Twenty-four(24) hour notification is required for inspections. S. Workers'Comp insurance information is required with this application. Declaration: Construction/installation must conform to NYS Fire Prevention & Building Code and/or manufacturer requirements. The applicant or owner agrees to comply with all applicable laws, ordinances, regulations and all conditions that are part of these requirements and also will allow the inspector to enter the premises to perform the required inspections. I have read and agree to the above: 0 (, PRINT NAME: 00,bf,lkJ A SIGNATURE: OUDATE: 5 I�J Principle Structure Packet Revised December 2020 F Ma's�1 Office Use Only Permit#: Town of Queensbury Permit Fee:$ 742 Bay Road,Queensbury, NY 12804 P:518-761-8256 www.gueensbury.net Invoice#: FUEL BURNING APPLIANCE & CHIMNEY APPLICATION **ONE APPLICATION PER APPLIANCE** Project Location: 2) e0i U2. Tax Map ID#: Room of Install: aS ke- Planned Install Date: T 10 FUEL BURNING APPLIANCE INFORMATION: TYPE OF DEVICE: Stove _Fireplace Insert ,Fireplace _Fuel Fired Equipment (Garage Only,.18 clearance per IMC 304.3) _Fireplace,factory built** (**Manufacturer's name: Model #: ) SOURCE OF HEAT: Wood _Coal _Pellet Gas CHIMNEY INFORMATION: _ Masonry(require plans to be submitted): block brick stone _ Flue: le _steel _size, in inches _Material*: _double-wall _triple-wall _insulated (*Manufacturer's name: �a, -f 01)1 Model#: ) -t-T90 Principle Structure Packet Revised December 2020 CONTACT INFORMATION: PLEASE PRINT LEGIBLY OR TYPE, PLEASE INCLUDE AN EMAIL ❑ Check if all work will be performed by property owner only • Installer/Builder: Workers' Comp documentation must be submitted with this application Contact Name(s): Contractor Trade: Mailing Address, C/S/Z: Cell Phone:_( ) Land Line: _( ) Email: Contact Person for any questions regarding this project: Cell Phone:_�) Land Line: � ) Email: ADDITIONAL INFORMATION: 1. Two (2) inspections are required. A rough-in inspection, prior to installation and a final inspection, after installation. 2. Manufacturer's installation manual must be available at the time of inspection. 3. Masonry fireplaces & chimneys require plans to be submitted. 4. Twenty-four(24) hour notification is required for inspections. 5. Workers'Comp insurance information is required with this application. Declaration: Construction/installation must conform to NYS Fire Prevention & Building Code and/or manufacturer requirements. The applicant or owner agrees to comply with all applicable laws, ordinances, regulations and all conditions that are part of these requirements and also will allow the inspector to enter the premises to perform the required inspections. I have read and agree to the above: PRINT NAME: Z SIGNATURE: (XV,.,/ DATE: Principle Structure Packet Revised December 2020 SEPTIC DISPOSAL PERMIT . office use only APPLICATION Permit#: Town dQueensbw7 Permit Fee:$ Invoice#: 742 Bay Road,Queensbury,NY 12804 P:518-761-8256 www.gueensbury.net Septic Variance? Y N Flood Zone? Y N Dr Wetlands? Y N Reviewed By: Project Location Holly Lane and Assembly Point �C(� D Tax Map #: 239.12-2-35 AUG 19, 2021 RESIDENCE INFORMATION: TOWN OF O EE�BUR`f �u�l_�l r 'Oriis Year Built Gallons #of bedrooms: X gallons per =total daily flow per day bedroom Garbage Grinder Yes No 1980 or older 150 Installed? (choose one) ❑ 0 1981-1991 130 Spa or Hot Tub Yes No 1992-Present 110 4 110 440 . Installed? (choose one) ❑ 0 PARCEL INFORMATION: Topography Flat Rolli.ng ❑ Steep'Slope ' % Slope Soil Nature 0 Sand ❑ Loam ❑ Clay ❑ Other, explain: Groundwater At what depth? >7ft Bedrock/Impervious material At what depth? >7ft Domestic Water Supply ❑ Municipal ❑ Well OLAke (if well.or lake, water supply from any septic system absorption is >100ft Percolation Test Rate: 6-7 per minute per inch (test to be completed by a licensed engineer/architect)-- PROPOSED SYSTEM INFORMATION: Tank size 1,500 gallons (min. size 1,000 gallons, add 250 gallons for each garbage cylinder or spa/hot,tub System Absorption field w/#2 stone Total length ft.; Each Trench ft. Seepage Pit w/#3 stone. How many: ;.Size: . Alternative System Bed or other type:pressure disuibuted bed Holding Tank System Total required capacity? tank size ; # of tanks Septic Application Revised April 2021 CONTACT INFORMATION: PLEASE PRINT LEGIBLY OR TYPE, PLEASE INCLUDE AN EMAIL • Applicant: Name(s): Environmental Design Partnership M a i l i n g Ad d re s s, C/S/Z: 900 Route 146 Clifton Park,NY 12065 Cell Phone: Land Line: 518-371-7621 Email: gvuillaume@edpllp.com • Primary Owner(s): Name(s): Chris Abele . Mailing Address, C/S/Z: 14 Corporate Drive Clifton Park,NY 12065 Cell Phone: 518-365-4989 Land Line: 518-373-9613 Email: cabele@abelebuilders.com ❑ Check if all work will be performed by property owner only • Contractor: Contact Name(s): Contractor Trade: Mailing Address, C/S/Z: Cell Phone: Land Line: Email: "Workers' Comp documentation must be submitted with this application" • Engineer(s): Name(s): Environmental Design Partnership Mailing Address, C/S/Z: 900 Route 146 Clifton Park,NY 12065 Cell Phone: Land Line: 518-371-7621 Email: gvuillaume@edpllp.com Contact Person for Compliance in regards to this project: Gavin yuillaume,BrandonFerguson Cell Phone: Land Line: 518-371-7621 Email: gvuillaume@edpllp.com,bferguson@edpllp.com NOTES: 1. Alarm system and associated electrical work must be inspected by a Town approved electrical inspection agency; 2. We will no longer allow systems to be covered until such time as an as-built plan is received and approved. The installed system must match the septic layout on file—no exceptions. 3. As- built drawings must be submitted prior to the inspection, if there has been a change to the submitted plans. 4. If, for any reason, the building permit application is withdrawn, 30% of the fee is retained by the Town of Queensbury. After 1 year from the initial application date, 100% of the fee is retained. Declaration: Any permit or approval granted which is based upon or is granted in reliance upon any material representation or failure to make a material fact or circumstance known by or on behalf of an applicant, shall be void. I have read the regulations and agree to abide by these and all requirements of the Town of Queensbury Sanitary Sewage Disposal Ordinance. PRINT NAME: SIGNATURE: DATE: Septic Application Revised April 2021 � 1 Residential Plan Review: 1- and 2- Family Dwellings Y/N/NA (1 of 2) ,0,,5. Two (2) full sets of plans -e� Over 1,500 sq. ft. requires engineering stamp Design loads on plans: 115 Wind Floor Loads 40 psf S (North of Rte. 149 60) 50 Ground Snow Load Sleeping Areas &Attics 30 psf Calculations Decks 40 psf Wind design for lake front properties Window schedule with glass size & main doors/Air leakage < .5 cfm for doors, < .3 cfm for windows/Tempered glass in bathrooms 61- 1 Door sche ula a/Main entrance 36" door �--, S Emergency Escape or Bedrooms & Habitable Space �('4 6 Above-grade: 5.7 sq. ft. �S Grade: 5.0 sq. ft. 24" (h) x 20" (w) minimum -cam 44" maximum height above door Window control devices 24" or less 211 story or 72" above grade Egress window from basement 5.0 sq. ft. -C ,c J ( 5 P� e Floor system sizing per table 502.3.1 ' Lq Residential check ERI or Prescriptive method ,J'k Driveway length: 300' ormore-12' width required/500' or more, turnaround required ..p,S Foundation drainage on plans, if required 6" drop in 10' exterior grade Framing cross section for each roof line, vertical fire stopping every 10' where ` required/joist spans pg. 127 Ice & snow shield-24"from exterior wall �S Platforms at exterior doors Stairway headroom 6'8"; all stairs 36" width -cS Stair run and rise J Winder run and rise 1- Spiral stairs meet requirements -e S Smoke detectors—battery backup & proper location, interconnected cis Bathroom fixtures—proper clearance Hall width-36" width Handrails more than four risers on open sides Railing &guards > 30"/basement stairs included/closed risers more than 4" in height Safety glazing notes for required areas Garage fire separation:%" gable en /5r/8' rider living space &%" on walls/20 min. door and closer Garage floor sloped Attic access: gasket seal & R-value equal to roof insulation Roof over 30"-22" x 30"/Crawl spaces 18" x 24" access Residential Plan Review Revised March 2018 Residential Plan Review: 1- and 2- Family Dwellings Y/N/NA (2 of 2) r e( Carbon Monoxide detector outside lowest sleeping area, on every level & interconnected "4 J within 15' of sleeping area Soil test results, if required S Septic to well or water line separation All paperwork signed Note on plans energy saving light bulbs 75% -� Blower door test agency paperwork I-ro Floodplain Permit required -check map: 2 feet above flood elevation ,eS Hurricane clips required tit S Floors less than 2 x 10 covered by W gypsum or 5/8" wood panel -'3 : Manuals S &J required for heating system. Cold air return hard piped �.! Separate room for draft HVAC or hot water heater with fresh air HRV shown and calculations -Q� Baffles at eaves for insulations and knee walls Makeup air for range hood >400 cfm Continuous header for garage doors to end wall Chimney rain cap shown for fireplaces Deck hold down shown not less than 4 lags and bolts per table 507.2 Residential Plan Review Revised March 2018 TOWN OF OUEENSBURY 742 Bay Road, Queensbury, NY. 12804-5902 Septic System Checklist Plan to scale Received Deep hole perc test results from engineer/Architect if applicable(Town Approved Engineers and Architects;June 30 to April 15 Town Engineer for unapproved Engineers and Architects) All wells on property and adjacent properties shown 1 ater line shown Municipal or well 10'separation to any part of system -�70 L*V4C— -11211 W Setback to property lines show 10' or more for any part of system Septic tank and pump stations 10'from foundation 50'from any well/lake/wetland 10' from any waterline XIA Septic tank to foundation crawl space/slab on grade,grade in crawl space must be above top of septic tank for 0',Separation required (field verification required)%li Septic tank sized for number of bedrooms and add 250 gals for Jacuzzi tubs/garbage grinder each *Leech Field 20'from foundation 100'from any well 10'from water line 94 Seepage pit 150'from well 50'from septic tank IVIA-Seepage Pits 3-times diameter apart 14 Septic tank and pump stations over 30 gallons 50'from watercourse or wetland q6�distance from bottom of trench or system 24"to bedrock or mo ling 36"within 10 'of Lake George , t;sLeech field 100'from watercourse or wetland �6Toe of mound or bottom of retaining wall 10'from property line 100'from well 20' from Foundation Jl Provide Engineer/Architect stamp for bed or design systems ADepartment of Health Approval for all mobile home park new systems Flood Plain requirements NV 2' above established flood elevation to bottom of system - All tanks anchored or 2' above flood elevation Revised 4/15/2021 Abele Guest Cottage September 10, 2021 � - PY - MANUAL S - Project Information Design Information Name Abele Guest Cottage Outdoor Design Temperature-Summer" 85Fdb/71 Fwb Address Assembly Point Road Indoor Design Temperature-Summer 75Fdb City Queensbury Indoor Design%RH-Summer 50% State NY Zip Code 12845 19ytdoor Design Temperature-Winter -4Fdb System ID Project Location Elevation 335 System Type Air-Air,Cooling Only,Single-Speed Compressor,Mild Winter or Latent Load Manufacturer Carrier Fumace#, 59MN7808OC21-20 AFUE. 97.2 Proposed Manufacturer Carrier AHU/Coil# CNPVP4221ALA SEER 15.0 Equipment Manufacturer Carrier Condenser# 24ACC642A0030 HSPF Manufacturer Package# Fan Speed Med Heat Total Sensible Latent Manual J Load Calculations Loss BTUH BTUH' BTUH SHR 50826 31827 27907 3920 0.877 Enter the listed capacities from the manufacturers cooling performance charts that are equal to 75 IF db)&63(F wb)indoor design temperatures here Out DB per OEM Chart 85Fdb/71 Fwb Design Return Air Total Sensible Latent In DB per OEM Chart 75Fdb CFM. SHR p (Fwb) BTUH:- BTUH BTUH Capacity from MFG table 30,580 10,170 0.75 . Excess Latent Capacity Calculation 40,750 3,125 3,125 Capacity @ Design Conditions 33;705 7,045 0.83 Mfg.Equipment Match-up Adjustment Factor 1,409 63 1.00 1.00 Altitude Adjustments 1.00 1.00 Capacity @ Design Conditions . 40,750: 33,705 7,045, 0.83. Equipment Capacity as a%of Design Oversizing Limits 115% 150% Altitude Adjustments Capacity Capacity Balance Supplimental 1.00 Heat Pump Data @ 47°F db @ 17°F db Point Heat Required (if applicable) Cap.@ 47°F db Cap.@ 17°F db Select Furnace or Boiler Option Input Output Altitude Furnace ,/°of Load Oversing Capacity. Capacity. Adjustment Capacity Limits mac e Data(if applicable) 80,000 77,760 1.00 77760 153% 200% Electric Furnace KW Proposed KW Required %of Load Oversizing Limits 14.89 175% Notes: 1. Condensing Unit:One nominal size lower would result in insufficient sensible cooling capacity. 2. Furnace:Heating section equipped with modulating gas. ( oil Project Name: Abele Residence Address: 10 Polk Drive,Queensbury,NY OUTDOOR DESIGN CONDITIONS Weather station:Glens Falls AP Summer Outdoor F: Summer Indoor F: Design Grains: Daily Range: u • i Winter Outdoor F: -Winter Indoor F: r Cooling RH: a Elevation(Ft): LOAD CALCULATION TOTALS HVAC System:FURNA Heated square footage: Heating BTUH: = . Cooled square footage: Cooling BTUH: RICO Heated volume(above grade CF): lam CFM: Cooled volume(above grade CFj IBM Sensible cooling: NNW Exposed wall area(SF): EEO Latent cooling: SHR: Load Calculation Cooling. Heating- 0 . 20,000 40,000 60,000 BTUH Approved ACCA MJ8 Calculations Calculations are based on the ACCA Manual J,81h Edition,and are approved by ACCA. All computed calculations are estimates on building.use,weather data, and inputted values such a R Values„window types, duct loss, etc. Equipment selections should meet both the latent and sensible gain as well as building heat loss. HEATING AND COOLING LOADS HEATINQ LOADS Heating Loads �ECTI•N AREA • r above6GradeWalls aboveGradeWalls 2.193 10,548 windows n v; 26.8% ceilings 1,214.i 2.605 ceilings doors 24 835 _ r ` ducts 0 M673 6•y: doors . . i infiltration 0 11,525 infiltration. ` ducts °. skylights 0 0 2 " `:-� 2:3% windows 576 13,640- Totals 50,826 COOLING LOADS Cooling Loads. AEDExcursion • AEDExcursion .0 482 p windows aboveGradeWalls aboveGrade Walls 2-193 1.468 0' 'appliances 0 10,728 358 occupants appliances 6.8°1 34,a ceilings 1.214.1 1.127 0 infiltration s ceilin doors 24 237 0 g ducts 0 3.537 1,143 ducts doors infiltration 0 697 .1,120 14.7% 0.-_V occupants 0 1.150 1.000 - plants 0 0 300 skylights 0 0 0 windows 576 8,481 0 Totals 27.907 3,921 1 Air System Sizing Summary for ABELE RESIDENCE Project Name:Abele 08/26/2021 Prepared by:HESNOR ENGINEERING CO. 04:43PM Air System Information Air System Name...............................ABELE RESIDENCE Number of zones.......................................----.----......----..---.............3 EquipmentClass--•-------------•-•-----.................................UNDEF Floor Area-----.....--•---•--•--------•--•----..........................................3060.0 ft Air System Type.....................................7............................VAV Location..........................................................Albany,New York Sizing Calculation Information Calculation Months...............................................Jan to Dec Zone CFM Sizing...........................Peak zone sensible load Sizing Data..............................................................Calculated Space CFM Sizing.................Individual peak space loads Central Cooling Coil Sizing Data Total coil load.............................--------------------------------------------2.4 Tons Load occurs at...............................................................Aug 1600 Total coil load.............................:....•--....................--............28.8 MBH OA DB/WB...............................................................---90.0171.0 °F Sensible coil load.............•---••--•---------•----------..................----26.7 MBH Entering DB/WB....................--.....:.............-------.......69.5160.1 °F Coil CFM at Aug 1500.......................................-------......1720 CFM Leaving DB/WB.......... ..........................................65.0/54.1 °F Max block CFM at Jan 0000 ......................................1720 CFM Coil ADP...........................•...........:............................................63.4 °F Sum of peak zone CFM---------------------------------------------------1720 CFM Bypass Factor..........-•------------------------------------------------......------0.100 Sensible heat ratio...........................................................0.927 Resulting RH............-•-•-----•------•---••---•-------------..................------.....57 % CFM/Ton------------------------------------------------•---.........................716.8 Design supply temp......:.........................................................55.0 °F ft2fTon--------------------------------------------------------.......................1275.4 Zone T-stat Check....:.-....--•--•-------•--------------.........................3 of 3 .OK BTU/(hr•ft2)----------•--•...................... .......... ............. .......... .........9.4 Max zone temperature deviation..........................................0.0 °F Water flow @ 10.0°F rise.................:.............................6.76. gpm Preheat Coil Sizing Data No heating coil loads occurred during this calculation. Supply Fan Sizing Data Actual max CFM at Jan 0000........................................1720 CFM Fan motor BHP............................... 0.00 BHP .....--.........---..--.....-..........-.- Standard CFM....................................................................1702 CFM Fan motor kW------------------------------------------------------............------....0.00 kW Actual max CFM/ft2........................................................ -0.56 CFM/ft2 Fan static------------------------------------------------------............------............0.00 in wg Outdoor Ventilation Air Data Design airflow CFM------------------------------------------------------------------0 CFM CFM/person---•----•-----•-----•--.......------.........................................:.0.00 CFM/person CFM/ft2....................................................................................0.00 CFM/ft2 Hourly Analysis Program 5.10 Page 1 of 3 Zone Sizing Summary for ABELE RESIDENCE Project Name:Abele 08/26/2021 Prepared by:HESNOR ENGINEERING CO. 04:43PM Air System Information Air System Name"..............................ABELE RESIDENCE Number of zones"......"..."...-....."""."..................................................3 Equipment Class----".....................................................UNDEF Floor Area............................................................"----•-•--........3060.0 ftz Air System Type-"--".................................................•---........VAV Location..........................................................Albany,New York Sizing Calculation Information Calculation Months...............................................Jan to Dec Zone CFM Sizing...........................Peak zone sensible load Sizing Data..............................................................Calculated Space CFM Sizing.."..............Individual peak space loads Zone Terminal Sizing Data Reheat Zone Zone Design Minimum Reheat Coil Htg Unit Htg Unit Mixing Supply Supply Coil Water Coil Water Box Fan Airflow Airflow Zone Load. gpm Load gpm Airflow Zone Name CFM CFM CFM/tt= MBH 2O.0°F MBH 2O.0°F CFM Zone 1 224 224 0.45 9.6 0.96 0.0 0.00 0 Zone 2 7811 7811 0.601 33.41 3.341 0.01 0.001 0 Zone 3 1 6301, 6301 0.501 26.91 2.691 0.01 0.001 0 Zone Peak Sensible Loads Zone Zone Zone Cooling Time of Heating Floor Sensible Peak Sensible Load Area Zone Name (MBH) Cooling Load (MBH) (ft=) Zone 1 2.5 Jul 1400 6.0 500.0 Zone2 13.5 Aug 1500 20.9 1295.0 Zone 3 1 8.41 Jul 1600 16.8 1265.0 Hourly Analysis Program 5.10 Page 2 of 3 r� Zone Sizing Summary for ABELE RESIDENCE Project Name:Abele 08/26/2021 Prepared by:HESNOR ENGINEERING CO. 04:43PM Space Loads and Airflows Time of ' Cooling Peak Air Heating Floor Zone Name/ Sensible Sensible Flow Load Area Space Space Name Mult. MBH Load (CFM) (MBH ftz CFM/ft= Zone f 1-Hallway 107A 1 0.1 Jul 1500 5 0.2 40.0 0.14 1-M Bedroom 107 1 1.6 Jul 1500 140 3.5 250.o 0.56 1-M Bath 109 1 0.4 Jul 1300 39 1.2 120.01 0.32 1-M Closet 108 1 0.4 Jul 1000 - 40 1.1 90.0 0.44 Zone 2 2-Closet 101 1 0.1 Sep 1400 5 0.1 15.0 0.33 2-Closet 112A 1 0.0 Jul 1500 2 0.1 10.0 0.24 2-Foyer 100 1 2.4 Oct 1300 130 1.9 70.0 1.86 2-Hallway 110A 1 0.8 Jul 1700 42 1.1 80.0 0.52 2-Kitch/Dining 104/5 1 4.3 Jun 1700 227 6.6 570.0 0.40 2-Living Rm 103 1 6.0 Aug 1500 319 8.7 330.0 0.97 2-Mud Room 110 1 0.1 Jul 1500 4 0.3 50.0 0.07 2-Pantry 112 1 0.1 Jul 1500 3 0.2 30.0 0.10 2-Powder 106 1 0.4 Sep 1400 22 0.7 50.0 0.45 2-Stairs 102 1 0.5 Aug 1600 27 1.2 90.01 0.30 Zone 3 3-Bath 204 1 0.4 Jul 1600 28 1.1 100.0 0.28 3-Bedroom 203 1 1.4 Jul 1500 100 3.0 180.0 0.56 3-Bedroom 205 1 1.3 Jul 1600 93 2.8 200.0 0.46 3-Bedroom Hall 202 1 1.0 Jul 1700 68 1.2 70.0 0.97 3-Bedroom Hall 214 1 0.1 Jul 1500 8 0.5 80.0 0.10 3-Bunkroom 208 1 2.2 Jul 1600 155 3.5 280.0 0.55 3-Closet 203A 1 0.1 Jul 1500 8 0.3 50.0 0.16 3-Closet 205A 1 0.11 Jul 1500 7 0.2 40.0 0.18 3-Closet 208A 1 0.1 Jul 1500 4 0.1 15.0 0.29 3-Shared Bath 206 1 0.5 Jul 1500 35 1.2 100.0 0.35 3-Stairs 201 1 1.7 Sep 1400 124 2.9 150.0 0.83 Hourly Analysis Program 5.10 Page 3 of 3 Noe E M m R rt' Fresh Air Systems 110 CFM AVS HRV Top ports: A110H65RT Side ports: A110H65RS ®AVS• FILECOPY 35to112CFM@0.2 in. w.g. 35 to 100 CFM @ 0.4 in. w.g. C UL ��WAIP,p9y � �� ®.► 9�W e NVI CERTIFIED eo2a0 Parts/Motor HRV Core Introducing the industry's most advanced residential fresh air Description system,created to offer a universal platform specifically designed and improved to make contractors life easier and more profitable while delivering constant superior air quality. • SRE of 68%at 0°C and 60%at-25°C (64 CFM) • Ports size: 5" • Thanks to the Virtuo Air TechnologyTM,the airflow . Recirculation mode calibration and auto-balancing are achieved quickly and . Recirculation defrost maintained throughout the life of the product . Painted door, corrosion resistant galvanized body • Select the desired CFM (from 35 to 110 CFM) using the . One-piece molded insulation shell, no air leakage very first integrated LCD screen.The airflow is then set (expanded polystyrene; UL 94 HF-1 certified) up automatically • Virtuo constant airflow and auto-balancing device • Integrated electronic airflow measurement device with (patent pending) real time LCD • Motorized dampers (no additional backdraft dampers • Integrated diagnostic tool required) • Equipped with PMSM ECM motors for a very low power . Integrated "snap-in" drain system installed in seconds consumption with no additional parts (drain hose included) • Suspended installation (chains included) . 6' power cord OR • Unit electrical characteristics:120 volts,60 Hz, 2.5 A,90 W • Wall-mount installation (universal brackets included) . Sound: 66.8 dBA at 92 CFM @ 0.4 in. w.g. • installation with 2 brackets 60.1 dBA at 64 CFM @ 0.2 in. w.g. • installation with 4 brackets ADVANCED 20-40-60 Polypropylene crossflow core, impact resistant AUTOMATIC TOUCHSCREEN DEUD[E Dimensions: 12"x 12"x 9" (30.5 cm x.30.5 cm x 23 cm) Ivy _ MERV 8 grade washable standard filter (included) i Optional MERV13 grade filter part no.V24285 There are 3 optional main controls and 2 optional auxiliary • • controls available. Refer to Wall Control specification sheet for more information. • Complete line of registers and diffusers • Compatible with the Tandem transition (part no. 14690) (for units producing up to 110 CFM only) PRODUCT SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE. 5" PORTS DIMENSIONS (Top PORTS) I - Exhaust air from building Total assembled weight:approx 35 Ibs(15.9 kg)(core included) 2 - Fresh air to building Shipping weight:approx 42 Ibs(19 kg) ®I �I® 3 - Exhaust air to outside 4 - Fresh air from outside 4� _ Clearance for ducting 1 1 0 5 TVP. 21 8 ra at - - 1- ra W 211/2 11/8 j ,I Clearance required for �.f maintenance ILatches 183/4 i �` -8—)-- -( 16%-� Drains Power cord Terminals PORTS DIMENSIONS • PORTS) Total assembled weight:approx 35 Ibs(15.9 kg) (core included) Shipping weight:approx 42 Ibs(19 kg) 1 - Exhaust air-from building 231/2 2 - Fresh air to building 1 2 3 - Exhaust air to outside 4 - Fresh air from outside o 5 nP. 4 3 _] 8—� Clearance ' for ducting 21 —s� 191/8 Clearance required for maintenance —183/4— j -8—1- 16% Drains Latches Power cord Terminals Dimensions shown in inches VK0116 Defrost Homeshield"m Defrosting System DISCRETION OUTDOOR TEMPERATURE No negative pressure is created (Factory setting) -5°C To-15°C -15°C To-27°C -27°C AND LESS by air exhausted to-the outdoors 23°FT05'F 57TO-17°F -17°F AND LES since the air is recirculated into CFM AIR E%C1IANGE DEFROST AIR EXCHANGE DEFROST AIR ERCNRNGE DEFROST the house, helping to prevent any . IN MINUTES IN MINUTE IN MINUTES IN MINIM IN MINUIES IN MINUTES 0 to 59 32 7 25 7 20 10 backdraft. 60 to 90 50 7 35 1 7 25 10 91 and more 22 7 1 18 7 16 30 'Outdoor temperature is read by a thermistor located inside the unit,next to fresh air from outdoor port. 0 PLUS OUTDOOR TEMPERATURE -5°C TO-15°C 15°C To-27°C 27°C AND LESS 23°F To 5°F 5°F To-17°F -17°F AND LESS CFM AIR FXOIANGE DEFROST AIR F%0 0.NGE DEi Wi AIR E%-E DEFROST IN MINUTES IN MINUTEs IN MINUIES IN MINUTES IN MINUTES IN MINUTES 0 to 59 28 7 20 1 7 16 10 60 to 90 45 7 28 1 7 20 10 91 and more 18 7 14 1 7 12 SO 'Outdoor temperature is read by a thermistor located inside the unit,next to fresh air from outdoor port. Virtuo�Fan Curves with Thanks to Virtuo Air TechnologyTM, no need to balance the unit manually. Both PMSM motors are controlled by an artificial intelligence performing 120 readings per minute then processing this information to maintain the requested airflow. For typical installation, Virtuo will ensure.a balanced ventilation at every selected speed regardless of the weather conditions, the type of connection, the variable speed furnace/AHU, the stack effect, the filter clogging and so on. This results in peace of mind for installers and users knowing that the unit will always remain balanced and that it will maintain its maximum heat/energy recovery efficiency. STATIC STATIC NEr NET GROSS GROSS GROSS GROSS PRESSURE PRESSURE SUPPLY SUPPLY AIRFLOW AIRFLOW AIRFLOW AIRFLOW (PA) (IN.W.G.) AIRFLOW AIRFLOW SUPPLY SUPPLY EXHAUST ExHAUST oa (L/s) (CFM) (L/s) (CFM) (LDS) (CFM) 25 0.1 56 119 58 123 58 123 07 — —I 50 0.2 53 112 55 117 55 117 75 0.3 49 104 50 106 50 106 100 0.4 1 47 100 48 102 48 102 3 O.s 125 0.5 44 93 45 95 45 95 — ! i 150 0.6 39 83 40 85 40 85 175 0.7 33 70 34 72 34 72 200 0.8 26 55 27 57 27 57AIRFL aR I I aLANCREMENT a � IO I BI I I { o 10 zG 30 JO 50 60 TO 80 90 iW 130 120 uo ! Grossm flO ICFMI EnergyPerformance SUPPLY NET AIRFLOW POWER SENSIBLE ADJUSTED APPARENT TEMPERATURE SENSIBLE CONSUMED RECOVERY RECOVERY SENSIBLE `C •F L/S CFM WATTS EFFICIENCY EFFICIENCY EFFECTIVENESS* HEATING 0 32 30: 64 33 68 71 72 0 32 43 90 47 1 63 66 68 -25 -13 1 30 1 64 33 60 62 72 'Data not certified by HVI. �Requirements and Standards • UL 1812 compliant (safety) • Complies with ROHS 2015/863 directive Could be installed in compliance with CSA F326 • Compliant with Prop 65 • Performance tested as per CSA C439 Standard • Meets Novoclimat requirements when used in conjunction with wall control Advanced Touchscreen 1 Project: Remarks Location: Part no.: Qty.: Submitted by: Date:. v 9= m A R Venmar Ventilation ULC,550,Lemire Blvd,Drummondville(Quebec) 1-800-567-3855 AVS HV! wwwMeemarca A710d210310E khan eurs d'air - 110 i3 min- eEMMF=:1r�• g P / — Bouches sur le dessus: VRC A11OH65RT I, Bouches laterales: A110H65RS v E nimlAlr� �7AV5 35 a 112 pia/min @ 0,2 po d'eau 35 a 100 pia/min @ 0,4 po d'eau ANZ•■ C R rysO� ♦ G e e pHVI viRruo �fGAt�'~ p*�pnE \d��� �6yyub' CERTIFIED VB0280 1 PIECES/MOTEUR NOYAU VRC Voici 1'echangeur d'air residentiel le plus avolue de I'industrie. II , _ a et@ tree pour offrir une plateforme universelle sp6cifiquement con4ue et amelioree pour rendre la vie des contracteurs plus • Efficacite de recuperation sensible de 6�a 0°C et de facile et plus rentable tout en offrant une qualite d'air superieure constante. 60 % a -25°C (64 pi3/min) • Grace a Virtuo Air TechnologyT11, la calibration et ['auto- • Dimension des bouches: 5 po balancement du debit d'air sont atteints rapidement et • Mode recirculation maintenus pour la duree de vie du produit • Degivrage par recirculation • Selectionner le pia/min souhaite (de 35 a 110 pia/min) a • Porte peinte, boitier en acier galvanise resistant a la I'aide du tout premier ecran ACL integre. Le debit d'air corrosion .est ajuste automatiquement • Coque isolee, moulee, monobloc, aucune fuite d'air • Appareil electronique de mesure du debit d'air integre (Polystyrene expanse;certifie UL 94 HF-1) avec affichage LCD en temps reel • Virtuo dispositif d'auto-balancement et de debit d'air • Dispositif de diagnostic integre constant (en attente de brevet) Touter les unites ont des moteurs PMSM (moteur • Volets motorises (aucun volet anti-retour additionnel synchrone a aimant permanent) ECM (moteur a requis) commutation electronique) offrant une tres faible • Systeme de drainage integre; le raccordement du boyau consommation electrique s'effectue en quelques secondes (boyau inclus) • Installation avec chaines (incluses) • Cordon d'alimentation de 6 pi OU • Caracteristiques electriques:120 volts, 60 Hz, 2,5 A,90 W • Installation murale avec supports (inclus) • Son: 66,8 dBA a 92 pi3/min @ 0,4 po d'eau • installation avec 2 supports 60,1 dBA a 64 pi3/min @ 0,2 po d'eau • installation avec 4 supports _ • Polypropylene de type courants croises, resistant aux • • chats AVANc@EA DELUXE • Dimensions: 12 po x 12 po x 9 po (30,5 cm x 30,5 cm x AUraMATIQUE tCRAN TAcn E 20-40-60 23 cm) d Filtre standard lavable de grade MERV 8 (inclus) Filtre optionnel de grade MERV 13 piece no V24285 II y a 3 commandes principales optionnelles et • Gamme complete de grilles et de diffuseurs 2 commandes auxiliaires optionnelles disponibles. Se . Compatible avec le kit de transition Tandem referer a la fiche technique des Commandes murales pour (piece no 14690) (pour les appareils produisant un obtenir plus d'information. maximum de 110 pi3/min seulement) TOUTES LES SPECIFICATIONS SONT SUJETTES A CHANGEMENTS SANS PREAVIS. 1 - Aspiration d'air vicie Poids total assemble:approx 35 lb.(15,9 kg) (noyau inclus) 2 - Distribution d'air frais ® Poids a 1'expedition:approx 42 lb(19 kg) 3 - evacuation d'air vicie 4 - Aspiration d'air frais 4- Degagement pour conduits �0 5 nP. 21 8 1 211/2 ❑ 191/8 Degagement requis pour entretien ILoquets 8—��161/e—� Drains Cordon- Bornes d'alimentation Poids total assemble:approx 35 lb(15,9 kg) (noyau inclus) Poids a 1'expedition:approx 42 lb(19 kg) 1 - Aspiration d'air vicie 2sv2 2 - Distribution d'air frais 3 - evacuation d'ai,r vicie 1 2 4 - Aspiration d'air frais To5nP. 4 3 i Degagement 8—�-4 pour conduits 21 191/8 -Degagement requis pour entretien —183/4—� �—8—j-jE i6%—� Loquets Drains Cordon 3ornes d'alimentation Les dimensions montrees sont en pouces SystChme de d6givrage Systlemede degivrage Homeshieldmc DIscRETION TEMPERANRE EXTERIEUgE AucunepressionnEgativen'eStcrel=_ (R2glage en urine) e -5°CA-15°C -15°CA-27°C -27°CErMDINS par 1'evacuation d'air a 1'ext6rieur 23°FATF 5°FA-17°F -17°FErmows PI'/MIN EGNANGE DAm DECIVRAGE EOI-OAIR DEGNRAGE EONANGE O'AIR DEGIYRAGE puisque celui-ci est recircule dans A EN NINUfE6 EN MIND EN MINUTES EN MINUTES EN WNUTES EN MINUTES la maison, aldant a pr2venir tout 0h59 32 7 25 7 20 10 60�90 50 7 35 7 25 10 refoulement d'air. 91etPlus 22 7_ 18 7 164 10 La temperature exterieure Est lue par un thermistor situ@ a I'inWieur de i'appareil,pMs de la bouche d'aspiration d'air frais. O Pws TEMPERATURE ExTERIEURE -5°C A-15°C -15°C A-27°C -27°C Er Mows 23°F A 5°F 5°F A-17°F -17'F Er Mows PI'/MIN ET]LWGE DAIR DEGNRAGE 11N IEUAIR DELI—U E0 GE UAIR DEGNRAGE EN MINUTES w MINUTES EN MINUTES EN MINUTE$ EN WNUTES EN MINUTES 0 h 59 28 7. 20 7 16 10 60 a 90 45 7 28 7 20 10 91 et plus 1 1 7 14 7 12 10 La temp dw.re extdrieure Est lue par un thermistor situ6 h I'interieur de I'appareil,pres de la bouche d'aspiration d'air frais. Courbesde ventilationavec Virtuo Grace a la technologie Virtuo, plus besoin d'equilibrer I'appareil manuellement. Les deux moteurs PMSM sont contrMs par une intelligence artificielle effectuant 120 lectures par minute, puis traitant cette information pour maintenir le debit d'air demande. Pour une installation typique, Virtuo fera en sorte que. la ventilation soit equilibree 6 chaque vitesse selectionn@e peu importe les conditions climatiques, le type de connexion, la fournaise/1'appareil de traitement de I'air a vitesse variable, I'effet de convection, ('obstruction du filtre et ainsi de suite.Cela fera en sorte que les installateurs et les utilisateurs auront ('esprit tranquille sachant que I'appareil derheurera toujours equilibr2 et qu'il conservera son efficacit6 de recuperation de chaleur/d'energie maximale. PREssm PRESSION DEBIT NET DEBIT DEBIT DEBIT DEBIT DEBIT 09 STATIQUE STATIQUE DE LAIR NET DE BRUT BRUT BRUT BRUT (PA) (PO EAU) FRAIS LAIR DE LAIR DE LAIR DE LAIR DE LAIR Vs) FRAIS FRAIS FRAIS VICIE VICIE 0.7 I (P13/MIN) (L/s) (P13lMIN) (LJs) (W/MIN) 25 0.1 56 119 58 123 58 123 o,s — 50 0,2 53 112 55 117 55 117 75 0,3 49 104 50 106 50 106 100 0,4 47 100 48 102 48 102 v o,4 125 0,5 44 93 45 95 45 95 150 0.6 39 83 40 85 40 85 _ ° 0,3 175 0,7 33 70 34 72 34 72 d l 200 0,8 26 55 r 27 57 27 57 0,z 0,1 0 ]0 20 30 40 SO 60 70 60 90 l00 110 120 130 MR d'air b"(pPjmin) Rendement dnergLitique TEMP.D AIR DEBIT NET DE EFFICACITE DE FRAIS LAIR PUISSANCE EFFICACRE DE RECUPERATION SENSIBLE CONSOMMEE RECUPERATIDN SENSIBLE •C . AJUSTEE CHAUFFAGE 0 32 30 64 33 68 71 72 0 32 43 90 47 63 66 68 -25 -13 30 64 33 60 62 72 'Donnees non homologuees par le HVI. Normes et exigences • Conforme a la norme UL 1812 (securitO Conforme a la directive ROHS 2015/863 • Peut etre instal16 selon les exigences CSA F326 Conforme a Prop 65 • Performance test@e selon les normes CSA C439 • Rencontre les exigences Novoclimat lorsqu'utilis6 avec la commande murale Avancee a ecran tactile Projet: Remarques Lieu: No de pike: Quantite: Soumis par: Date: v 1—= r,m Fl ram• mvi, Venmar Ventilation ULC,550,Boul.Lemire,Drummondville(Quebec) 1-800-567-3855 INMEMBER wwwvenmarca A110d210310E Leg�� eDr TOWN OF QUflSNSE BUILDING CODES Insul-Tech Energy Solutions LLC DATE:211112022 108 Troy Rd. East Greenbush,New York 12061 Cell 518-937-5965 Fax 518-479-0124 Contact:Jay Abele (518)320-4375 ORDER DATE JOB 2/l/2022 91 Assembly Point Rd.Lake George, N.Y. DESCRIPTION _ AMOUNT Roof Deck:To apply seven inches of closed cell foam to the roof deck. Resulting in an R-Value of 49 in the roof deck. Walls:To apply five inches of open cell foam to all exterior walls,including gable ends,and garage walls. Resulting in an R-Value of 22 in the walls. Crawlspace Rim Joist:To apply three inches of closed cell foam into the rim joist of the entire crawlspace area.Resulting in an R-Value of 21 for the rim joist. Crawl Space Walls:To apply two and a half inches of closed cell foam to all exterior crawl space walls. Resulting in an R-Value of 17 for the crawl space walls. Thermal/Ignition Barrier:To apply DC-315 thermal/ignition barrier paint over the spray foam insulation in the crawlspace area. Garage Ceiling_To apply seven inches of open cell foam to the garage ceiling joists. Resulting in an R-Value of 30 in the garage ceiling. HUNTSMAN N BUILDING SOLUTIONS HEATLOK® HFO HIGH LIFT' TECHNICAL DATA SHEET Heatloke HFO High L'rft is a two component,closed cell,spray applied,rigid polyurethane foam system.This product uses recycled plastic materials,rapidly renewable soy oils,and the blowing agent has zero ozone depleting potential.Heatlok HFO High Lift complies with the intent of the International Code Council's residential and commercial building codes and is commonly used as a thermal insulation,air barrier,vapor retarder and water resistive barrier in above grade,below grade,interior and exterior applications. PROPERTIES ASTM D 1622 Core Density 2.0-2.4 Ib/ft3 32.0-38.4 kg/m3 ASTM C 518 Aged Thermal Resistance 1"=6.3 ft2h°F/BTU 1"=1.10 Km2/W 3.5"=26 ft2h FBTU 3.5"=4.57 Krn/W ASTM E 283 Air Leakage @ 75 Pa @ 1" <0.02 Usm2 ASTM E 2178 Air Permeance @ 75 Pa @ 1 <0.02 Usm2 Water Vapor Permeance 1.56 perms 89.25 ng/Pa•s•m2 ASTM E 96 Class III vapor retarder per IBC Section 202 @ 1" Class[]vapor retarder @ s 1 perm 1.875" 47.63mm ASTM D 2842 Water Absorption(volume) 0.870 ASTM D 1621 Compressive Strength 34.8 psi 240 kPa ASTM D 1623 Tensile Strength 101.3 psi 698 We ASTM D 2126 Dimensional Stability @ 158°F(70°C)97%R.H.(168 hours) -3.7(%volume change) VOC Emissions UL Environment(Greenguard Gold) Meets Criteria ASTM C 1338 Fungi Resistance No fungal growth ASTM D 2856 Closed Cell Content 91% ASTM C 1029 Standard specification for spray applied rigid cellular Type II Compliant polyurethane thermal insulation FIRE TEST RESULTS Surface Burning Characteristics,4"thick Class I ASTM E 84 Flame Spread Index 10-15 Smoke Developed 350-400 Ignition Barrier-Compliant with 2012,2015,2018&2021 IBC and IRC,and ICC-ES AC 377 Appendix X AC-377 Appendix X,for use in attics and crawl spaces without a prescriptive ignition barrier or Pass intumescent coating. Thermal Barrier-Compliant with the,2012,2015,2018&2021 IBC and IRC,as an interior finish withoi it NFPA 286 a 15 minute thermal barrier when coated with DC-315 at 18 mils wet film thickness,12 mils dry film Pass thickness,or BlazelokTm TBX at 18 mils wet film thickness,12 mils dry film thickness. ASTM D 1929 Ignition Properties(spontaneous ignition temperature) 766°F(408°C) RECYCLED RENEWABLE CONTENT Recyclable Content 19% Renewable Content 6% PROFILEREACTIVITY Cream Time Gel Time Tack Free Time End of Rise 0 -1 seconds 2 seconds 73-4 seconds 3-4 seconds Page 1 of 2 LIQUID COMPONENT PROPERTIES PROPERTY A-PMDI ISOCYANATE HEATLOK HFO HIGH LIFT RESIN Color Brown Blue Viscosity @ 770F(250C) 180—220 cps % 500—800 cps Specific Gravity 1.24 1.17—1.21 Shelf Life of unopened drum properly stored 12 months 6 months Storage Temperature 50—100°F(10—38°C) 59—77°F(15—25°C) Mixing Ratio(volume) *See SDS for more information. RECOMMENDED PROCESSING" • • Initial Primary Heater Setpoint Temperature 105—1150F 41 —460C Initial Hose Heat Setpoint Temperature 105—1150F 41 —460C Initial Processing Setpoint Pressure 1200—1400 psi 8274—9653 kPa Substrate&Ambient Temperature Summer>50OF Summer>10°C Winter>15OF Winter>-90C Moisture Content of Substrate 519% s19% Moisture Content of Concrete Concrete must be cured,dry and free of dust and form release agents. *Foam application temperatures and pressures can vary widely depending on temperature,humidity,elevation,substrate,equipment and other factors.While processing,the applicator must continuously observe the characteristics of the sprayed foam and adjust processing temperatures and pressures to maintain proper cell structure,adhesion,cohesion and general foam quality.It Is the sole responsibility of the applicator to process and apply Heatlok HFO High Lift within specification. General Requirements:Equipment must be capable of delivering the proper ratio(1:1 by volume)of polymeric isocyanate(PMDI)and poyol blend at adequate temperatures and spray pressures.Substrate must be at least 5 degrees above dew point,with best processing results when ambient humidity Is below 80%. Substrate must also be free of moisture(dew or frost),grease,oil,solvents and other materials that would adversely affect adhesion of the polyurethane foam. Applicators should limit the application of this product to no more than a thickness of 6.5"(165mm)per pass(after expansion)to avoid fire hazards(including spontaneous combustion)resulting from excessive heat generation.If subsequent passes are needed,applicators should waft until the core temperature of the foam has dropped below 100°F to allow any reaction heat to dissipate from the prior applications before attempting to reapply the product. RECOMMENDED Ambient Temperature Maximum Pass Dual Pass(x"+x'J s70°F(21°C) 6.5" 3.25"+3.25" >70°F(21°C);<80"F(27°C) 4" 3.25"+3.25" >80°F(27-C) 3.25" 3.25"+3.25" Heatlok HFO High Lift must be separated from the interior of the building by an approved thermal barrier or an approved finish material equivalent to a thermal barrier in accordance with applicable codes.Heatlok HFO High Lift must be sprayed at a minimum thickness of 1"per pass.This product must not be used when the continu- ous seance temperature of the substrate or foam is below-60"F(-51*C)or above 180"F(82"C).Heatlok HFO High Lift should not be used to cover flexible ductwork. Disclaimer:The information herein is to assist customers in determining whether our products are suitable for their applications.We request that customers inspect and test our products before use and satisfy themselves as to contents and suitability.Nothing herein shall constitute a warranty,expressed or implied,including any warranty of merchantability or fitness,nor is protection from any law or patent Inferred.All patent rights are reserved.The foam product Is combustible and must be protected in accordance with applicable codes.Protect from direct flame and spark contact,around hot work for example.The exclusive remedy for all proven claims is replacement of our materials. (& 0qT IYY 'a u abaa Intertek **'* 3315 E Division St Pa e 2 of 2 Arlington,TX 76011 I HUNTSMAN 9 Phone:(817)640-4900 AN:20.00063 1 REV.09.29.21 www.huntsmanbuildingsolutions.com BUILDING SOLUTIONS 1.1` NTSI\/1AR BUILDING SOLUTIONS / AGRIBAL.ANCEO TECHNICAL DATA SHEET Agdbalance®is a two component,open cell,spray applied,semi-rigid polyurethane foam system that contains more than 20%renewable agricultural based materials(refined vegetable oils).This product is a fully water blown foam system having a low in-place density with excellent adhesion to various substrates and to Itself.Agribalance incorporates the single phase solution technology developed by Huntsman Building Solutions for excellent shelf life and consistent processing.Agribalance complies with the intent of the Internation- al Code Council's residential and commercial building codes for spray polyurethane foam plastic insulation.Agribalance meets the USDA guidelines for incidental food contact. ••- ASTM D 1622 Density 0.6—0.8 Ib/ft3 9.6—12.8 kg/m3 ASTM C 518 Aged Thermal Resistance(R-value @ 1 inch) 4.45 ft2h°F/BTU 0.78 Km2/W ASTM E 283 Air Permeance @ 75 Pa @ 3.5"(75 Pa=25 mph wind) <0.02 Usm2 Air Permeance @ 500 Pa @ 3.5" 0.003 Usm2 Air Permeance @ 1000 Pa @ 3.5" 0.006 Usm2 Air Permeance @ 1500 Pa @ 3.5" 0.011 Usm2 Air Permeance @ 2000 Pa @ 3.5" 0.018 Usm2 ASTM E 96 Water Vapor Permeance @ 5" 4.95 perms 2 83 ng/Pa•s•m2 ASTM D 2126 Dimensional Stability @ 158°F(70°C)97%R.H.(28 days) 3.16(%volume change) ASTM D 1621 Compressive Strength 1.86 psi 12.82 kPa ASTM D 1623 Tensile Strength 3.87 psi 26.68 kPa FIRE TEST RESULTS ASTM E 84 Surface Burning Characteristics,5.5"thick Class I Flame Spread Index 15-20 Smoke Developed 400 Ignition Barrier—Compliant with 2006,2009&2012 IBC and IRC,and ICC-ES AC-377 NFPA 286 Appendix X,for use in attics and crawl spaces with:BlazelokTM I134 at 5 mils dry film thickness, Pass 9 mils wet film thickness,or No Bum Plus XD at 6 mils dry film thickness,10 mils wet film thickness,or Heatlok Soy at 2"thick NFPA 286 Thermal Barrier—Compliant with the 2006,2009&2012 IBC and IRC,as an interior finish without a 15 minute thermal barrier with BlazelokTm TBX at 15 mils dry film thickness. Pass ASTM D 1929 Ignition Properties(spontaneous Ignition temperature) 968°F(520°C) PROFILE;REACTIVITY Cream Time Gel Time Tack Free Time End of Rise 1—2 seconds 3—4 seconds 6—7 seconds 6—7 seconds LIOUfb COMPONENT PROPERTIES PROPERTY A-PMDI ISOCYANATE AGRIBALANCE RESIN Color Brown Amber Viscosity @ 770F(25°C) 180—220 cps 250—450 cps Specific Gravity 1.24 1.08—1.12 Shelf Life of unopened drum properly stored 12 months 12 months Storage Temperature 50—100°F(10—38°C) 50—100°F(10—38°C) Mixing Ratio(volume) 1:1 1:1 `See SIDS for more Information. Page 1 of 2 RECOMMENDED,PROCESSIOR Initial Recirculating Setpoint Temperature 80—850F 27—30°C Initial Primary Heater Setpoint Temperature 120OF 490C Initial Hose Heat Setpoint Temperature 120OF 49°C Initial Processing Setpoint Pressure 1300 psi 8963 kPa Substrate&Ambient Temperature Summer a 50°Fa Summero 10°C Winter>30 F-60 F Winter>-1 C-16 C Moisture Content of Substrate s 19% s 19% Moisture Content of Concrete Concrete must be cured,dry and free of dust and form release agents. 'Foam application temperatures and pressures can vary widely depending on temperature,humidity,elevation,substrate,equipment and other factors.While processing,the applicator must continuously observe the characteristics of the sprayed foam and adjust processing temperatures and pressures to maintain proper cell structure,adhesion,cohesion and general foam quality.It is the sole responsibility of the applicator to process and apply Agribalance within specification. General Requirements:Equipment must be capable of delivering the proper ratio(1:1 by volume)of polymeric isocyanate(PMDI)and polyol blend at adequate temperatures and spray pressures.Substrate must be at least 5 degrees above dew point,with best processing results when amblent humidity is below 80%. Substrate must also be free of moisture(dew or frost),grease,oil,solvents and other materials that would adversely affect adhesion of the polyurethane foam. Agribalance must be separated from the interior of the building by an approved thermal barrier or an approved finish material equivalent to a thermal barrier in accordance with applicable codes.Agribalance must be sprayed at a minimum thickness of 3"per pass.This product must not be used when the continuous seance temperature of the substrate or foam is below-60OF(-51°C)or above 180OF(82°C).Agribalance should not be used in contact with bulk water,below grade or to cover flexible ductwork. Disclaimer:The information herein is to assist customers in determining whether our products are suitable for their applications.We request that customers inspect and test our products before use and satisfy themselves as to contents and suitability.Nothing herein shall constitute a warranty,expressed or implied,including any warranty of merchantability or fitness,nor is protection from any law or patent inferred.All patent rights are reserved.The foam product is combustible and must be protected in accordance with applicable codes.Protect from direct flame and spark contact,around hot work for example.The exclusive remedy for all proven claims Is replacement of our materials. °$w (01), us 1 1CC rGREENj`� GREEN YYAcSr�Aaoa Intertek APPROVED 3315 E Division St Pa e 2 Of 2 Arlington,TX 76011 I HUNTSMAM 9 Phone:(817)640-4900 AN:20.00100 1 REV:12.07.20 www.huntsmanbuildingsolutions.com BUILDING SOLUTIONS ENVIRONMENTAL DESIGN GID PARTNERSHIP; LLP. 900 Route 146 Clifton Park,NY 12065 (P)518.371.7621 (F)518.371.9540 edpllp.com Shaping the physical environment October 28, 2022 Mr. Craig Brown RECEIIN LZD Zoning Administrator Town of Queensbury 742 Bay Road NOV 0 4 2022 Queensbury, NY 12804 TOWN OF QUEENSDURY Regarding: Rockhurst LLC PLANNING OFFICE Cottage Lot 3 Polk Road Site Plan/Stormwater Compliance Dear Craig: In compliance with application approvals granted by the Town of Queensbury, we offer the following regarding the referenced project. The Site Plans prepared by EDP and approved by the Planning Board on May 26, 2021, involved the construction of a single-family residence located at 3 Polk Road. Our office has been on the site to observe the stormwater device installation, and all proposed stormwater management devices are in place and functioning properly as designed. As there were slight changes to the site construction during the course of the project, we have provided an As-Built Plan which identifies the stormwater and erosion control measures implemented at this site. Based on our inspections of the site improvements as installed, it is our opinion that the work completed is in compliance with the intent of the approved design plans, has been properly stabilized and is satisfactory for a certificate of compliance. If additional information is required, please contact our office at your convenience. Very truly yours, rt . Gavin Vuillaume, RLA Partner I% ENVIRONMENTAL DESIGN PARTNERSHIP, LLP. 900 Route 146 Clifton Park,NY 12065 (P)518.371.7621 (F)518.371.9540 edpllp.com Shaping the physical environment September 30, 2022 Town of Queensbury Building &Codes 742 Bay Road Queensbury, NY 12804 Attn:John O'Brien, Charlie Dyer Re: Rockhurst, LLC Residence Wastewater—3 Polk Drive Dear John: In compliance with application approvals granted by the Town of Queensbury I offer the following regarding the referenced project. The design plans, prepared by this office and reviewed and approved by the Town as associated with the wastewater system application, are as follows: rr PEW U Abele Cottage Lot Owner: Rockhurst, LLC 3 Polk Drive 2022 • Sheet 3 Utility Plan ENSBURY Sheet 6 Existing Conditions Survey CODES • Sheet 7 Details Dated: May 10,2021 During the course of construction, I was on the job site to observe key components of the system installation. I have attached a plan of the design layout which is labeled (and serves) as the`as-built' plan. The septic system components consist of a 1500 gallon concrete septic tank, a 1000 gallon concrete pump tank with a duplex pump assembly, a time-dosed control panel and a pressurized -stone absorption bed. The tanks and bed were constructed in the locations as noted on the approved plan—Utility Plan Sheet 3. During the construction phase the Owner,with concurrence from EDP and the Town of Queensbury Building Department, made revisions to the basic components of the system. I have updated the Detail Plan (Sheet 7)to reflect the final component details of the `as-built'system. We completed a system test to the pressurized distribution laterals on September 23rd with the Town representative (CD) in attendance. Alarm systems were checked and determined functional. Floats and controls were set for system operation. Based on my inspection of the system start-up it is my opinion that the wastewater system is in compliance with the intent of the approved design plan as well as the subsequent as-built plans, and is ready for operation. The Owner is now looking to receive a CO for this residence. Please contact me should you require any further information. Sincerely, AS BUILT Dennis MacElroy eC ^ 2) Cc: Chris Abele