Blower Door Test cc C>U(:)3- Loz l MTIG] Lq [3 Sustainable Solutions for Efficient Environments Blower Door Test -#24 - Stewarts Quaker Road Queensbury Addition FIRM: CUSTOMER: MTI-Mechanical Testing, Inc. Hilltop Construction PROJECT#: 4 Chelsea Place, Suite 102 BDT#24 Clifton Park NY 12065 PROJECT ADDRESS: PHONE: 777 Quaker Road .(518)450-7292 Queensbury NY FAX: DATE: (518)450-7295 2022-03-25 CONTACT: Austin Roggen a ATI Eq Lq 13 Sustainable Solutions for Efficient Environments LOCATION: PROJECT NUMBER: CONTACT: Blower Door Test#24-Stewarts Quaker Road BDT#24 Austin Roggen Queensbury Addition 777 Quaker Road Queensbury NY Table of Contents Blower Door Test 3 ......................................................................................................................................................................,........................................................................................._................... ........................_........ 3/24/2022 -Blower Door Test ..................._...............................................................................................................................................__.....,............................_..........................................................................................................._........_............................ Page 2 of 3 2022-03-25 MT1 IR Lq [3 Sustainable Solutions for Efficient Environments LOCATION: PROJECT NUMBER: CONTACT: Blower Door Test#24-Stewarts Quaker Road BDT#24 Austin Roggen QueensburyAddition 777 Quaker Road Queensbury NY ' Blower Door Test 3/24/2022 - Blower Door Test TESTINFO Date of Test 3/24/2022 I Leakage Code 0.40 ..................................................................................................................................................!................................................................................................................................................. i Technician Name Austin Roggen Pass/Fail Pass TEST DATA Floor Plan Area 297 sq.ft No.of Tests Performed 3 CFM ....................... Enclosed Volume 2970 Test Average 615 CFM ............................................-------------------------.........--------------------------------------------------------•--------------------------------------------------------=------------------------------------------------------------------------------------- Envelope Surface Area 1602 sq.ft I Air Changes Per,Hour 12.42 —.................................... ..............................:................................................................................................................................................. Test Pressure -75.00 kPa Leakage.Per SF 0.38 IMAGES: Test Data ED - , III -,r, ' :� 1 6.0 i:• ;. STOP A - STOP 1 3/24/2022-Blower Door Test Page 3 of 3 2022-03-25 Certificate of Gauge Calibration Issued by: Retrotec Certificate Number: 409481 100208 Calibration Date: 2021-01-19 Results: As Found ACC H E D I T E D ------------------ 1060 E Pole Rd. Everson, WA, USA 98247 AC-1 943 T: +1 (360) 738-9835 This calibration laboratory has been assessed by the ANSI- ASQ National Accreditation Board and meets the E: calibration@retrotec.com W: www.retrotec.com requirements of international standard lSO/IEC17025. Instrument: Description: Pressure and Flow Gauge Calibrated by:Tina Lukyanets Manufacturer: Retrotec l inv Model Number: DM32 10A Serial Number: 409481 Signature Environmental conditions: Temperature: 20°C±2°C Relative Humidity: 50% ±10% Mains Voltage: 120V±10V Mains Frequency: 60Hz ±1Hz Comments: Results recorded as received. No adjustment performed. Calibration Information: The Device was calibrated against laboratory standards whose values are traceable to recognized national standards. The uncertainty represents an expanded uncertainty using a coverage factor of K=2 to approximate a 95% confidence level. In tolerance conditions are based on test results falling within specified limits without taking uncertainty into account. The uncertainty evaluation has been carried out in accordance with ISO/IEC 17025 requirements. Calibration Procedure: CP-35-01 This Calibration Certificate shall not be reproduced except in full,without written approval from Retrotec. S Certificate of Gauge Calibration Issued by: Retrotec Certificate Number: 409481 100208 Calibration Date: 2021-01-19 Results: As Found Calibration Results Channel A Channel B Applied Value(Pa) Reading(Pa) Error(%) Applied Value(Pa) Reading(Pa) Error(%) 749.95 -753.76 0.51 -749.95 -750.28 0.04 -599.96 -603.20 0.54 -599.96 -600.92 0.16 -300.00 -301.46 0.49 -300.00 -300.29 0.10 -149.98 -150.64 0.44 -149.98 -150.10 0.08 -99.98 -100.42 0.44 -99.98 100.02 0.04 -75.01 -75.32 0.41 -75.01 -75.02 0.01 -50.01 -50.25 0.48 -50.01 -50.00 0.02 -25.02 -25.12 0.40 -25.02 -24.97 0.20 -14.99 -15.08 0.60 -14.99 -15.00 0.07 -9.99 -10.02 0.30 -9.99 -9.92 0.70 -0.02 0.01 N/A -0.02 0.00 N/A 9.99 10.02 0.30 9.99 10.07 0.80 15.00 15.08 0.53 15.00 15.08 0.53 25.00 25.12 0.48 25.00 25.10 0.40 50.00 50.24 0.48 50.00 50.14 0.28 74.98 75.33 0.47 74.98 75.17 0.25 99.99 100.46 0.47 99.99 100.20 0.21 150.01 150.68 0.45 150.01 150.26 0.17 299.96 301.10 0.38 299.96. 300.28 0.11 599.96 601.80 0.31 599.96 600.36 0.07 749.98 752.06 0.28 749.98 750.38 0.05 Instrument display resolution is 0.1 Pa. Uncertainties Calibration and measurement capability(Expanded Uncertainty)is.01 Pa+0.3%of reading(Range 0-20 000 Pa) based on a 95%confidence interval, using coverage of K=2. f I� i+ Initial The Pressure Range uncertainty limits are compliant with (meets or exceeds requirements from)the following standards or guidelines: Name Accuracy Requirements Expiration Date NFPA 2001 ±1 Pa±(10 to 50 Pa) 2022-01-19 EN13829 ±2 Pa(up to±60 Pa) 2026-01-19 ATTMA:TS1 ±2 Pa(up to±100 Pa) 2022-01-19 ASTM E779-10 ±5%or 0.25 Pa whichever is greater 2026-01-19 CGSB ±1 Pa(up to±50 Pa) 2022-01-19 FD P50-784 ±1%or 1 Pa whichever is greater 2022-01-19 IS014520 ±1 Pa(up to±60 Pa) 2026-01-19 EN15004 ±1 Pa(up to±100 Pa) 2026-01-19 USACE ±1%or 0.25 Pa±(25 to 250) Pa 2023-01-19 TITLE 24 ±1%or 0.2 Pa whichever is greater 2022-01-19 RESNET380 ±1%or 0.25 Pa whichever is greater 2022-01-19 IS09972 ±1 Pa(up to±100 Pa) 2026-01-19 FD E51-767 ±2.5%or 3 Pa whichever is greater 2023-01-19 a Certificate of Calibration Tested in accordance to ISO 9972, CGSB 2002,ATTMA-TS1,ASTM-E779, RESNET:Pass Issued by:Retrotec Certificate Number:202101180722-5FN102378 Calibration Date:2021-01-19 Results:As Left Calibration laboratory Retrotec 111111/1,Zii 1060 East Pole Road Everson,WA,US 98274 - +1(360)738-9835 _ ^ A C C R E D I T C- D CALIBRATION LABORATORY calibration@retrotec.com http://www.retrotec.com ` AC-1943 This calibration laboratory has been assessed by the ANSI-ASQ National Accreditation Board and meets the requirements of international standard ISO/IEC 17025.All pressure and flow devices used in this calibration are traceable to the National Institute of Standards and Technology. Device being calibrated: Description: Test Fan Manufacturer: Retrotec Calibrated by:Shelby Zettle Model Number: Model 5000 Shell Serial Number: SFN102378 Main Voltage: 120 V Main Frequency: 60 Hz Signature Reference Flow: Nozzle 2010 Chamber,in accordance with ANSI/AMCA 210-07 and ASTM E1258-88 standards: Device Under Test Gauge:DM-32 Gauge Serial number 408019 Reference Gauge: DM-32 Gauge Serial number 407350 Calibration Information: The Device was calibrated against laboratory standards whose values are traceable to recognized national standards.The uncertainty represents an expanded uncertainty using a coverage factor of K=2 to approximate a 95%confidence level. In tolerance conditions are based on test results falling within specified limits without taking uncertainty into account.The uncertainty evaluation has been carried out in accordance with ISO/IEC 17025 requirements. Calibration Procedure: Procedure ID No.CP-CHB-01 This Calibration Certificate shall not be reproduced except in full,without written approval from Retrotec. Name Calibration Expiration Date Name Calibration Expiration Date ISO 9972 2026-01-19 CGSB 2002 2026-01-19 ATTMA-TS1 2022-01-19 ASTM-E779 2026-01-19 RESNET 2026-01-19 Page 1 of 3 Calibration Date:2021-01-19 Certificate of Calibration Tested in accordance to ISO 9972, CGSB 2002,ATTMA-TS1,ASTM-E779, RESNET:Pass Issued by:Retrotec Certificate Number:202101180722-5FN102378 Calibration Date:2021-01-19 Results:As Left Calibration Results: Flow rates are corrected to STP conditions of 20'C,101.325 kPa,50%RH and Air Density: 1.19886 Humidity% BarometricChamber Fan Pressure Reference Fan Flow Range (RH) Temp(C) Pre sPs)re pressure(Pa) (Pa) Flow(m'/h) (m3/h) Error(%) Open 49.0 16.8 103.500 50.0 14.0 3601.68 3718.43 3.2% Open 48.4 17.0 103.500 49.7 89.5 9091.33 9429.42 3.7% Open 46.4 17.8 1 103.500 51.2 116.5 10334.78 10724.17 3.8% A 46.0 18.1 103.500 49.4 28.6 2768.41 2872.90 3.8% A 46.2 18.0 103.500 50.5 108.1 5367.96 5542.45 3.3% A 45.9 18.1 103.500 50.4 149.5 6332.78 6509.76 2.8% B8 45.3 18.4 103.500 50.9 59.4 1808.31 1859.13 2.8% B8 44.2 19.2 103.500 49.5 208.7 3483.31 3654.60 4.9% B8 43.9 19.3 103.500 51.1 264.6 3986.07 4155.91 4.3% B4 41.4 21.2 103.500 50.1 45.3 671.93 683.06 1.7% B4 41.2 21.3 103.500 50.1 198.4 1596.55 1609.66 0.8% B4 40.7 21.5 103.500 51.4 262.6 1835.88 1856.93 1.1% B2 41.9 21.2 103.500 50.9 64.7 300.10 301.77 0.6% B2 42.0 21.1 103.500 50.7 214.6 714.76 738.98 3.4% B2 42.4 20.9 103.500 50.8 275.5 821.83 851.76 3.6% B1 41.9 21.1 103.500 51.2 71.6 165.11 169.32 2.6% B1 41.8 21.1 103.500 51.0 202.2 344.93 354.16 2.7% 61 42.2 20.9 103.500 51.0 268.4 405.40 414.42 2.2% Calibration and measurement capability(Expanded Uncertainty) is 1.58%of reading, based on a 95%confidence interval, using a coverage of K=2 Page 2 of 3 Calibration Date:2021-01-19 Certificate of Calibration f i�' I !"tr) •LC Tested in accordance to ISO 9972,CGSB 2002,ATTMA-TS1,ASTM-E779, RESNET: Pass Issued by:Retrotec Certificate Number:202101180722-5FN102378 Calibration Date:2021-01-19 Results:As Left Published Flow Equation Parameters(Units in m3/h): Range Configuration n K . MF(Pa) Open 0.501 961.15 10 A 0.495 530.97 20 B8 0.541 198.52 40 Flow=P^n x K Where P=Fan Pressure in Pascals Range f a b c d MF(Pa) Configuration g B4 50 0.70 6.02908E-005 -4.02763E-002 12.7447 172.20 40 B2 50 0.85 1.41348E-005 -1.27530E-002 5.5253 -10.46 50 B1 1 50 0.20 9.07977E-006 -7.42104E-003 1 2.8765 -4.28 60 Flow=(PI xa)+(PZxb)+(Pxc)+d+((g- IPrAj)xf) Where P=Fan Pressure in Pascals Range Configuration K1 K2 K3_ Open 0 0.3 0 A 0 0.4 0 B8 0 0.7 0 B4 0 0.8 0 B2 0 1.0 0 B1 0 1.0 0 Date Format: This report adheres to ISO 8601: Data elements and interchange formats-Representation of dates and times. All dates on this report are in the format:YYYY-MM-DD. Page 3 of 3 Calibration Date:2021-01-19