2002-1048 TOWN OF QUEENSBURY
742 BayRoad,Queensbuiq NY 12804.5902 (518)761.8201
Community Development-Building&Codes (518)761.8256
CEEXT1 IFICATE 'v".r' '0'0CCUPANCjY
Permit Number. P20021048 Date Issued: Tuesday,November 07, 2006
This is to certify that work requested to be done as shown by Permit Number P2002104$
hasbeen completed.
Tax Map Number: 523400-308-005=0001-001-000-0000
Location: 393 WEST MT. Rd
Owner TERESA GENIER
Applicant: ROBERT&TERESA GIORDANO
This structure may be occupied as a:
Residential Alteration By Order of Town Board
TOVN OF QUEENSBURY
Issuance of this Certificate of Occupancy DOES NOT relieve the
property owner of the responsibility for compliance with Site plan,
Variance,or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement
Planning Board or Zoning Board of Appeals.
TOWN OF QUEENSBURY
742 Bay Road,Queensbury,N'Y,12804-5902 (518)761-8201
Community Development-Building&Codes (518) 761-8256
BUILDING PERMIT
Permit Number: P20021048 Application Number: A20021048
Tax Map No: 523400-308-005-0001-001-0160-0000
Permission is hereby granted to: ROBERT & TERESA GIORDANO
For property located at: 393 WEST MT. Rd
in the Town of Queensbury,to construct or place
at the above location in accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. Type of Construction Value
Owner Address: TERESA GENIER
393 WEST MT. Rd Residential Alteration $3,000.00
QUEENSBURY, NY 12804 Total Value $3,000.00
Contractor or Builder's Name /Address Electrical Inspection Agency
DONALD &VICKEY DEAN JR
30 RHODE ISLAND Ave
QUEENSBURY, NY 12804
Plans&Specifications
2002-1048 Robert and Teresa Giordano
384 sq ft RESIDENTIAL ALTERATION (CONVE E TO LIVING ROOM)
$40.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Wednesday, July 18, 2007
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at the Town ensb Mo a La!nfiary 06, 2003
SIGNED BY for the Town of Queensbury.
Director of Building&Code En orceme'nt
TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development-Building&Codes (518) 761-8256
BUILDING PERMIT
Permit Number: P20021048 Application Number: A20021048
Tax Map No: 523400-308-005-0001-001-000-0000
Permission is hereby granted to: ROBERT &TERESA GIORDANO
For property located at: 393 WEST MOUNTAIN Rd
in the Town of Queensbury,to construct or place
at the above location in accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. Type of Construction Value
Owner Address: TERESA GENIER Residential Alteration 3,000.00
393 WEST MT. Rd Total Value 3,000.00
QUEENSBURY,NY 12804
Contractor or Builder's Name/Address Electrical Inspection Agency
DONALD &VICKEY DEAN JR
30 RHODE IST.AND Ave
O1JFFNSB1JRY_NY 12804
Plans&Specifications
2002-1048 Robert and Teresa Giordano
384 sq ft RESIDENTIAL ALTERATION (CONVERT GARAGE TO LIVING ROOM)
$40.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Tuesday,January 06,2004
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at the TGW#n.Qlf Queel ury. o day,January 06,2003
SIGNED BY for the Town of Queensbury.
Director of Building&Code nforcement
- Buildin-'T46rmit Application
Town of Queensburji-'Dept of Community Development,742 Bay Road;Queensbury;NY
(518)761-8256
A permit.must be;obtained before beginning construction. - - Permit File Noa0QQ- t7 L[
No inspection will be made until applicant has received a Fee Paid
valid building permit: All applicants' spaces on this, Rea Fee Paid $
application must be completed and must appear on the y�—
application form. Reviewed-By:', r.
Applicant: otif�5'G� L i9�"J� Owner:,D2" --T J&Y'`� .
Address:- Ica .�'.5'G:��r 'c,�.J�is'G Address: 71g3 N,.t o a
Phone#( 1rP) Phone#
C,:=
Property Location: Lot-Number; / -House Number --
Subdivision Name: _ Tax Map Number:
❑ New Building: :residence t commercial Estimated Market Value of Construction:$
cr Addition: commercial If an Addition,what will use of new addition be?.
,Alteration:' residence commercial
❑ No change to exterior size: residence/cbrn'l-
❑ Other work(describe )
Check OccupancyInformation ie Floor 211,Floor Other floor Total
Below s 'ft sq:ft. sq.ft: Square Feet
Q' Sin a family dwelling "
❑ Two family dwelling
❑ Townho e
❑ _ Multifamily'dwelling
#of units'
❑- Office
o Mercantile
❑ Manufacturin
-"-- v. '"T car detachedgarage_ - .
o - '2 car detached garage _
❑ 3 car detached garage.
❑ - 1 car attached g
u 2 car"atta garage,
a" 3 e ttaehed garage ,
❑ ' Storage building-
commercial.
❑ Storage building
- residential _,
" Other
What is the proposed height of the structure X/0 feet inches
Will any second-hand or ungraded lumber be used_? If so,for what? A,a
Type of Heating System: electric/.oil / gas/wood /forced hot air/ baseboard/other:
Number of Fireplaces to be installed Number of-Woodstoves to be installed Q
List below the person(s)responsible for supervision of work as.regards to building codes:
Name Address Phone Number
Builder
Plumber "
Mason
Electrician
Declaration, please sign below after you have carefully read the statement:'
To'the Best of my knowledge the statements contained in this application,together with the plans and specifications
submitted,'are a true and complete statement of all proposed work to_be.done on the described premises and that all
provisions of the Building.Pode,the Zoning Ordinance and all other laws,peitauung to the proposed work shall be complied
with,-whether specified or noted;.and that'such work is authorized by the owner. Further,it is understood.that I/we shall
submit,prior to a Certificate of Occupancy or Certificate of Compliance being issued,as requested by the Zoning
Administrator o r of,Building'and Codes;an As Built Survey by a licensed surveyor;drawn to scale,showing actual.
location of alf new cons on
k, Signature: owner,aw_ner's agent,architect,contractor
vjeexc
Queensbury Building & Code Enforcement - Residential Final Inspection ,
OMce No. (518)761-8256 Arrive;� e ft: 3 a p
Date Inspection request received: Inspector's In ti
NAME: ' P RMIT#: --
LOCATION: L �1 ` -"' R D�TE: -- , --^
TYPE OF STRUCTURE:
Comments
Yes No N/A
Building Number/Address visible from road
Chimney Height/"B"Vent/Direct Vent Location
Fresh Air Intake
3 inch Plumbing Vent through roof minimum 6 inches
Roof Complete I Exterior Finish Complete
Platform at all exterior doors
Guards at stairs,decks,patios more than 30 inches above grade
Guard at stairwell at 34 inches or more
Guard at deck,porches 36 inches or more
Handrail Termination at Newell Post or Wall
Interior/Exterior Railings 34 inches to 38 inches
Interior Handrails @ stairs 2 or more risers
Grade away from foundation 6 inches with 10 feet
6 inch clearance to sill plate
Gas Valve shut-off exposed/regulator 18 inches above grade
Interior privacy/trim/doors/main entrance 36 inches
Bathroom/Kitchen watertight
Safety glazing/Window in stairwells safety glazing _
Interior Smoke Detectors:
Every level: Every Bedroom:
Outside every bedroom area:
Inter Connected: Battery backup:
Carbon Monoxide Detector
Attic access 30 inches x 22 inches x 30 inches(height)in accessible Brea
Crawl Spaces 18 inch x 24 inch access, 1 s .ft 150 s .ft.vents ;
Bathroom Fans,if no window
Plumbing fixtures
71,Foundation insulation
Floor truss,draft stopping finished basement 1,000 s .ft.
Emergency egress below grade
Gas Furnace shut-off within 30 feet or within line of site
Oil Furnace shut-off at entrance to furnace area
Furnace/Hot Water Heater operating
Low water shut-off boiler
Relief Valve(s)installed/Heat Trap/Water Temp 110
Enclosed Stairs Sheetrock Underside minimum'lz"Gypsum
Basement stairs closed rise>4 inches
Garage Floor Pitched
Garage fireproofing/%hour fire door/door closer
Duct work Sealed properly
Gas Logs in Sealed or Glass Enclosure
Final Electrical
Final Survey Plot Plan
As Built Septic System/Sewer Dept,Inspection Sticker
Site Plan /Variance required I
Flood Plain.Certification,if required
Okay to issue C/C or C/®[Temporary/Permanent
L:\Building&Codes FormslBuilding&CodesUnspection Forms\R.esidential Final Inspection Form revised_l00405.doc
\3 GooRA
Queensbury wilding & Code Enforcement - Residential Final Inspection }-
Office No.(518)761-8256 % Arrive: 2197b p a a p W
Date Inspection request received: Inspector's Initials:
NAME: ...y ( ) IT
LOCATION: c D E:
TYPE OF STRUCTURE:
Comments
Yes No N/A
Building Number/Address visible from road
Chimney Height/"B"Vent/Direct Vent Location
Fresh Air Intake
_
inch Plumbing Vent through roof minimum 6 inches
Roof Complete/Exterior Finish Complete
Platform at all exterior doors
Guards at stairs,decks,patios more than 30 inches above grade
Guard at stairwell at 34 inches or more
Guard at deck,porches 36 inches or more
Handrail Termination at Newell Post or Wall
Interior/Exterior Railings 34 inches to 38 inches
Interior Handrails @ stairs 2 or more risers
Grade away from foundation 6 inches with 10 feet
6 inch clearance to sill plate
as Valve shut-off exposed/regulator 18 inches above grade
Interior privacy/trim/doors/main entrance 36 inches
Bathroom/Kitchen watertight
Safety glazing/Window in stairwells safety glazing
Interior Smoke Detectors:
Every level: Every Bedroom:
Outside every bedroom area: -
Inter Connected: Battery backup:
Carbon Monoxide Detector
Attic access 30 inches x 22 inches x 50 inches(height)in accessible area
Crawl Spaces 18 inch x 24 inch access, I s .1-150 s .ft.vents
Bathroom Fans,if no window
fPlumbing fixtures
Foundation insulation ;
Floor truss,draft stopping fnushed basement 1,000 s .ft.
Emergency egress below grade
Gas Furnace shut-off within 30 feet or within line of site
Oil Furnace shut-off at entrance to furnace area
Furnace/Hot Water Heater operating
Low water shut-off boiler
Relief Valve(s)installed/Heat Trap/Water Temp 110
Enclosed Stairs Sheetrock Underside minimum%z"Gypsum
Basement stairs closed rise>4 inches
Garage Floor Pitched
Garage fireproofing/3/a hour fire door/door closer
Duct work Sealed properly
Gas Lo s in Sealed or Glass Enclosure
Final Electrical
Final Survey Plot Plan
As Built Septic System/Sewer Dept.Inspection Sticker
Site Plan /Variance required
Flood Plain Certification,if required
Okay to issue C/C or C/®[Temporary/Permanent
L:\Building&Codes Forms\Building&Codes\Inspection FormsiResidential Final Inspection Form—revised-1 00405.doc
Queensbury Building &Y CodecA Enforcement - Residential Final Inspection
Office No.(518)761-8256 0 Arrive: a m rt:
eiv Date Inspection request r c ed: Inspector's Initials: r
)v
NAME: P J IT#:
LOCA I ION: Al E:
TYPE OF STRUCTURE:RE:
Comments
Y N N/A
Chimney Ht./"B"Vent/Direct Vent Location
Fresh Air Intake
3 inch Plumb Vent through roof minimum 6"
Roof Complete/Exterior Finish Complete V
Guard 30 in.or more @)stairs,decks,patios
Guard at stairwell at 34 in. or more W/
Guard at deck,porches 36 in.or more
Exterior Finish Complete
Interior/Exterior Railings 34 in.to 38 in.
Platform at all exterior doors
Interior Handrails stairs 2 or more risers
Enclosed Stairs Sheetrock,Underside minimum V2"
Gypsum
Grade away from foundation 6 in.with 10 ft.
Handrail Termination at Newell Post or Wall
6 inch clearance to sill plate
Gas Valve shut-off exposed/regulator 18"above grade
Gas Furnace shut-off within 30 ft.or within line of site
Oil Furnace shut-off at entrance to furnace area
Furnace/Hot Water Heater operating
Low water shut-off boiler
Relief Valve(s)installed/Heat Trap/Water TeT2 110
Interior privacy/trim/doors I main entrance 36 in.
Bathroom/Kitchen watertight
Safety glazing/Window in stairwells safety glazing
Interior Smoke Detectors:
Every level: _ / Every Bedroom:
Outside every bedroom area: _
Inter Connected: i Batter backup:
Carbon Monoxide Detector
Bathroom Fans, if no window
Plumbing fixtures
Foundation insulation
Floor truss,draft stopping finished basement 1,000 sf
Emergency egress below grade
Basement stairs closed rise>4 inches
Garage Floor Pitched
Garage fireproofing/%hour fire door/door closer
Duct work Sealed properly
Gas Logs in Sealed or Glass Enclosure
Attic access 30 in.x 22 in.x 30 in.(ht.)In accessible area
Crawl Spaces 18"x 24"access, I sq. ft,-150 sq.ft.vents
Building No./Address visible from road 7`
Final Electrical
Site Plan /Variance required
Final Survey Plot Plan
As Built Septic System/Sewer Dept. Inspection Sticker
Flood Plain Certification, if required
Okay to issue C/C or C/0[Temporary/Permanent
L:\PamW\]3uildiniz&CodesUnspection Forms\Res. Final Insp. form 2,docLast printed 2/12/04
Framing / Firestopping Inspection Report
Office No. (518) 761-8256 Date Inspection reques eive
Queensbury Building&,Code'Enforcement Arrive: a pa a
742 Bay Road, Queensbury,NY 12804 Inspector's lnit*
NAME: PERMIT#: qqF
LOCATION: Sli? nmh INSPECTON:
TYPE OF STRUCTURE:
ool
Y - N N/A
aming OF COMMENTS
Jack Studs Headers
Bracing Bridging COMMENTS
Joist hangers
Jack Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
I Y2(w) 16 gauge(8) 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
Ice and snow shield 24 inches from wall
Fire separation 1,2, 3 hour
Fire wall'2, 3,4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side V2 inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
LASuel-lerningway\Building.Codes.Inspection.FORM STrarning Firestopping Inspection Report.doc Jan=7 28,2003.