Blower Door Testing - preliminary SUSTAINABLE
COMFORT
Preliminary Blower Door Testing
Site Testing Report
Memory Care
Project Information:
ILLI/Wellness Center
39 Longview Drive
Queensbury, NY 12804
Testing Parameters
Memory Care Apartments: 0.3 CFM/sf @ 50 Pa
Common Area: 0.4 CFM/sf @ 75 Pa
General Notes:
Sustainable Comfort will conduct infiltration testing on site at the Memory Care Building.
The apartment units will be tested following the RESNET sampling protocol which requires seven
consecutive passing tests,then allows one out of every seven units to be tested. At minimum one
unit from each unit type shall be tested and the dwelling units selected for testing must be
appropriately"representative" of the dwelling units in the building and demonstrate a similar
distribution of unit types, level, exposure,and orientation.
Proposed Sampling plan will not be disclosed to site team prior to testing. See Table 2:
Sampling and Testing Table below. .
Table 1: Unit Types
Enclosure Blower Door
UnitType Unit Modeled*Bedrooms *Bathrooms Area Area Volume Model Type Target Target CFM
1Br1stlrit 108 1 1 319.2 1295.3 2872R Multifamily 0.3CFM50/SF 388.59
18rlstEnd 164 1 1 3q5.951 14q5.31 3113.E 1 Multifamily 10.3CFM50/SF 1 433.59
Common Area 'Common 1, 0 1 0 -1102ql 299711 1q3603I I custom 1 11989
Submitted By:
Nick Hinman, Sustainable Comfort, Inc.
INSPECTION REPORT 1
SUSTAINABLE
COMFORT
Table 2: Sampling and Testing Table
UNIT
MODEL SET UNIT INFILTRATION SAMPLE SET
1Br1stlnt 108 388 MEMD009
1Br1stlnt 109 388 MEM0009
1Br1stlnt 110 388 MEM0003
1Br1stlnt ill 388 MEM0003
113rlstEnd 119 y33 MEM0003
18ristEnd 115 y33 MEM0003
113rlstEnd 116 433 MEMD003
iBrlstEnd 117 y33 MEMD003
113rlstEnd 120 y33 MEM0003
113rlstEnd 121 1433 MEM0002
113rlstEnd 122 L133 MEM0002
113rlstEnd 123 Q3 MEM0002
113r1stlnt 127 388 MEM0002
113r1stlnt 128 38B MEM0002
113r1stlnt 129 388 MEM0002
1Br1stlnt 155 388 MEM0002
1Br1stlnt 156 388 MEM0001
113r1stlnt 157 388 MEM0001
113r1stlnt 158 388 MEM0001
1Br1stEnd 161 433 MEM0001
1Br1stEnd 162 4133 MEM0001
113rlstEnd 163 4133 MEM0001
113rlstEnd 169 4133 MEM0001
1BrlstEnd 167 933 MEM0000
113rlstEnd 168 Q3 MEMOOOD
1BrlstEnd 169 Q3 MEMOOOO
1BrlstEnd 170 Q3 MEMOOOO
1Br1stlnt 174 388 MEMOOOO
1Br1stlnt 175 388 MEM0000
1Br1stlnt 176 388 MEMOOOO
#N/A
Common Area Common 11,989 MRYCMN
INSPECTION REPORT 2