Loading...
1999-118 CERTIFICATE OF OCCUPANCY TOWN OF QUEENSBURY WARREN COUNTY, NEW YORK • July 16 99 Date 19 41 / 4)1.) 99118 This is to certify that work requested to be done as shown by Permit No. • , has been completed. SINGLE FAMILY DWELLING This structure may be occupied as a LOT 8 2#1 7 8 HUDSON POINTE BLVD. Location HUDSON POINTE,INC. Owner TAX MAP NO 148 . -3-82 By Order Town Board TOWN OF QUEENSBURY Director of Bldg. ec Code Enforcement BUILDING PERMIT VALUE $ 16790IOWN . OF QUEENSBURY No. 99118 TAX MAP NO.. 148. —3-82. WARREN COUNTY, NEW YORK PERMISSION is hereby granted to HUDSON POINTE,INC. OWNER of property located at LOT 82#178 HUDSON POINTE" BOULEVARDreet,Road or Ave. in the Town of Queensbury,To Construct or place a SINGLE FAMILY DWELLING at the above location in accordance to application together with plot plans and other information hereto filed and approved and,in compliance with the Town of Queensbury Building and Zoning Ordinance. 1. OWNER'S Address is 300 ERIE BLVD. W. SYRACUSE:, NY 13202 - 2. CONTRACTOR or BUILDERS Name MICHAELS GROUP, INC. 3. CONTRACTOR or BUILDERS Address JIM CHANDLER, PROJECT MGR 1810 ROUTE 9 LAKE,. GEORGE, NY 12845 4..ARCHITECT'S Name NEW YORK BOARD 5. ARCHITECT'S Address -- - NEW YORK BOARD OF FIRE UNDERWRITERS 6. TYPE of Construction—(Please indicate by X) SINGLE FAMILY DWELLING ( )Wood Frame. ( ) Masonry '( )Steel 1 ) 7. PLANS and Specifications 271143.SQ FT SINGLE FAMILY DWELLING WITH 2—CAR ATTACHED GARAGE AS PER PLOT PLAN SPECIFICATIONS 8. Proposed Use . SINGLE FAMILY DWELLING . 333 April. 20 . 19 2001 $ PERMIT FEE PAID —THIS PERMIT EXPIRES (If a longer period is required an application for an extension must be made to the Building and Zoning inspector of the town of Oueensbury before the expiration date.) 20 April 19 1999 Dated at the Town of Queensbury this Day of SIGNED BYZ for the Town of Queensbury Building and Zoning Inspector . r Buildut,g Fern jit Application•' :• - - • (vih/1 of Qlieeiiow.y - Dellr. grCan,inuriry Development; 742 flay Road, Quccnsbu►y, NI' 12&r4 /761-8256f • lll/11,1) 1NU & COD1 ENFORCE MLN7' • INCE__ Rcduirentcnis prior to issuance pLltA�l'1'I�ILG NO.-- —�, of Iilis per:nil: A 11c:tntil nntsl Ire rllltnincd Ix.line -••------ ? ' ti �cli(nrs ..__._ — • 1'1;•lt�lall'ILG PAID�` Will co mg!' spill No nt.lx 7,r:iir Dowd Action /j/ will be ninrlc mg!' nl�ldil and has received ,- 45 —I g n vnt:II) IMII.I)INU rlatnal F. All Alva 1 Use • IIISCREAllON r v$ IMUSTIbd complcicd and-llrellni sluices no ads �sitmatine . K (_ Manning Board Action REVIEWED Dp .� of the applicant must a1pear on the SI'It / Subdivision /Oilier / Building bulxcror application lislut. 71.,.:4r.._ / Ittcrcntton.I ce Payment f he M.t llrtt�C!t (;Jtu111.r, inc. owner: Same npplicant: . � ,,6 , ZBZ Lilt D / • '�ildtcss: • Addle ,,. -0SBO -L •�hoc.�r ( 5 I 8 ) Phone # ) - ? ' G Properly localivn: t P , , --- T. Map Number '~. Subdivision Nsuuo:. �(us.U1L!! I)u�.ltte.T-- - - • Section Block" mt • tu►TUltr OF' PROPOSED WORK: ESTIbtltTED t•SnItKET VALUE i�7 K THE New Building: CONSTRUCTION: 1�;_----- residence / commercial Add.i.l;J.o to nid.i.ng: OCCUE'11ICX IllfO1t1 '1'xoN: rat; to / commercial. A1Lc :+ licn to unilti.nc : primary luidl uy - residence / commercial X Single Famtly Dwelling Two Family Dwelling Residence / Commercial _ himilW r no change to exterior size Off Office ; ` Et . Mercantile. Other Work (describe below) MatrufacturingAPR 0 9 1999 Other —•------ ,_ i , �� TO)lVf�l d3F t�UEEt.1�RUFlY GROSS. AREA OF PROPOSED STRUCTURE: ,ltt Oj EE • l l If ADDITION, oar 1st Floor I 7 eq. ft: �, of new addition be? t 2nd .Floor ' ►?,7 sq. ft. v N/A � � eq. ft. Other Floors (not unfinished cellar or baeemeub , ACCESSOitY BUILDIN1GS:. 2 car TOTAL FLOOR AREA: 1/ 1 (-1 Sc .ZJ \c� Detached Garage 1, car Attached Garage 1, 1 .1�'I N, _— Private ' Storage Building � C- Commercial Storage Building • SIZE of NEW STRUCTURE: Q, C0 OL'ller . ' 511 C LL'1' X FEET Will any second-hand or ungraded 1'oubeaLloil Toro: ib2- lumber be used? If eo, fok what? (habitable bl Stories : 2 (ltabitab.le ':pace only) J � I- feet �C UF• HEATING 5Y5'xCt•is Height (grade to ridge) : circle all whit Rill es) Number of fireplaces and/or woodstove ( Oil Gas' , Wood Electric / eboaoo / Other to be installed: -�_ Forced Hot Air / . Person responsible for supervision of work as regards to building . codes is : ___V11LSIlctl afx.1f.__EL!-ajia-Malicigl or—E-r- �t N me lt,ddreeoo phone r 518-668-331G iI u 1 Id e r: .l he 1�I cc.lt aQ f�S ri, 111c. 1810 R.te 9 t Ld.lte a)cc Ge e Plumber : I.ctya. I'1'.1.41tb.09,--16A 'c ft Road,jgc.nz Fattis NY 12801 518-198-4399 Mason : _.ULR_l(.r.l1.e.f.L._I3.o x---21.8_,._Gaa►1 dLLe.._---- - ! ___,18-3 7 i-9 9 2 2 El e c L-r 1 c i.a n: 9 4 4 E_1 cl.l /t-e _:t-•-•— (t.ei-I.� li. VJ CL.A11A17UN: Please ,rlgn below Oa you lun'c carefully react the statement. •'lb file best of my knowledge the statements contained in nithisent npplof aii ication, togwork toithothe ans mid specific tions subtuittcd,•are a true and complete and all the tICSC115CtI lilClniSC3 mid that all <ll'VVISIons or the complied willlc Cod ,whether Zoning specified Oror Ordinance and oilier laws pet brining to the proposed work shall be COior(bat such work is authorized by the owner' l;tltther, it is Compliance being i,;snc ,understood an�lAS I3Ull:1'll'LOTII'LiANtbyl Certificate of ota:rtl)aticy.or (;cttirrcale or wrrri . a licensed surveyor; dr; wn o ale, showing actual location or project on premises. • SiglratutC: r rr giwtmr's agent, architect, contractor) TOWN OF QUEENSBURY 531,Bay Rc,I.,.,Queensbury, NY 12804 APPLICATION FOR SOLID FUEL BURNING APPLIANCES AND CHIMNEYS • ,• D1'14 Date R; §I., t' I:90 f` ` ' x , T.:1M Permit No. i APPLICATION IS HEREBY,MADE.to•the Building Dept. for the issuance of a Building and Use Permit pursuant to the New York State Fire Prevention and Building Code. The applicant or owner agrees to comply with all applicable laws, ordinances, regulations, and all conditions that are part of these requirements and also will allow all inspectors to enter premises to perform required inspections. Please fill out additional form if more than one appliance and/or chimney. Applicant - --f t;,!irii/ .C' t` ; tr k APPLIANCE (check appropriate boxes) Address 2.0 1 {t: it .t < �2..,1 ❑ STOVE: ❑Wood o Coal o Pellet ❑ Gas _ 0 FIREPLACE INSERT ( £i '; i i)¢Pc , Zip I `z. ;.© FIREPLACE, FACTORY-BUILT: ❑ Wood 'ID Gas Phone i` ;;)-7---(.,` c t ><±- Ir'I 0 FIREPLACE, MASONRY: ❑ Wood ❑ Gas Owner .# i s,+`;t;4 i . x) ft 0 FURNACE: ❑ Wood ❑ Gas ❑ Oil Address- :,. , _ . _ IF-NON-MASONRY APPLIANCE: Manufacturer: Zip L CLI'> Model: Phone CHIMNEY (check appropriate boxes) *EXACT ADDRESS of proposed construction 1 t n , 1. 0 MASONRY: 0 Block 0 Brick 0 Stone ,: t Ic:.- ,,�t :' r 0 - e, i. . FLUE ❑ Tile ❑ Steel Size: inches CONSTRUCTION / INSTALLATION MUST 4O FACTORY-BUILT: CONFORM TO NYS FIRE PREVENTION & Manufacturer: Model: BUILDING CODE. CONSULT AVAILABLE Listed By: Number: TOWN OF QUEENSBURY HANDOUTS ❑ Double Wall ❑Triple Wall REGARDING REQUIRED INSPECTIONS. 0 Insulated 0 Direct Venting ❑ Chimney Liner Cashier's Department Town of Queensbury, New York Dept: Fire Marshal Amount Collected Amount Received Code Number Title (DC' A 173 3389 (190) Public Safety - .fir A 233 265.5 (230) Minor Sales 4 Fee Collected From or Refunded to: \ 0 (', �,= ' _ -,; / ( '; kvie Address �._ Dated: L1 Town Clerk or Deputy: White: Applicant Green: Fire Marshal Yellow: Bldg. Dept' Pink & Goldenrod: Cashier's Dept. b� A lication for`SEPTIC:`DISPOSAL .PERMIT . " PP Town of Queensbury 941-1/V Dept. of Community Development Permit No. Building &Codes Office 742 Bay Road Fee Paid $ Queensbury, NY 12804 Location of property for installation: LD - �—Q(AGt& \ c t�-ye/ i Property Owner's Name: 'fQ rn i( tuDi p Property Owner's Mailing Address: 100 1[UL,1#C q --�j 61e0,8( if& l Installer's Name: (J4t LLckL (.11,1ti,t17 j Phone # 10013 a I Dq . Number of bedrooms (if residential): Total daily flow: (IJL[J (residential -compute @ 150 gal./bdrm.) Topography: ✓ flat, rolling, steep slope % of slope - Soil Nature: / sand, loam, clay, other /depth: Ground water: at what depth? W feet / Bedrock or Impervious Material: .at what depth? feet Percolation test: not required, '& required [rate I min. per inch] Domestic water supply: municipal, well, " other If domestic water supply is a WELL, water supply from any septic absorption is feet. • PROPOSED SYSTEM Septic tank: Jp gallon (minimum size: 1,000 gal.) Tile field: each trench Sit feet / Total system length: 24(D feet Seepage pit(s): number of • / size each: ft. by ft. Size of stone to be used: #ajar / depth or thickness feet HOLDING TANK SYSTEM: (if required) Number of tanks: 13 I A- Size of each: gallons Alarm system and associated electrical.work to be inspected by a certified agent'.. • -:For your protection,`please note that pursuant to Section 136-29•of the Code of the Town of Qoaensbury;.any permit or approval granted which is based.upon or is granted.in reliance upon,any:material;nnarepresentat on or failure to make a -- material fact or circumstance known:by or on behalf of an applicant; shall be void. ' • I have read the regulations with respect to this application and agree to abide by these and all requirements of the Town of.- Queensbury Sanitary Sewage Disposal - Signature of responsible person:. Date ( 7/ Sent By: The Michaels Development Grp; 5188774679; Apr-9-99 9:45AM; Page 1/1 ;e;'Tc;o_NNORTH OFFICE At: 6684523 Ol+Vita 4 V:7 (.97:41 151E7937061 HAANEN ENGIPEERING PAGE 62 11111lN HAANEN, JENKIN & HUTCHINS, LLC Industrial Design St Project Management January 8, 1999 • Mr.Jim Chandler The Michaels Group 1810 Route 9 Lake George,NY 12845 Via Fax•468-4523 RR: Hudson Pointe PUD-Phase 2 Soil Percolation Tests Dear Jim: On January 7, 1999 we completed percolation tests on Lots#82 and 83,Hudson Pointe Blvd.The stabilized percolation rates are as follows: Lot#82 1 minutes 0 seconds Lot#83 2 minute 20 seconds Should you have any questions,please call. Sincerely, t ' l FIE " }4f. 72,0,44,, L ` ��v'vIC APR 0 9 1999 G.Thomas Hutchins.P.E. TOWN OF QUEENSBURY BUILDING AND CODE f.:146146029M.doc 254 BAY ROAD,QUEENSBURY, N.Y. 12844 PHONE(518) 793-7444•FAX(518)793-4061 RESIDENTIAL FINAL,INSPECTION REPORT Office No. (518)761-8256 Date inspection request received: Building& Code Enforcement , Dept. of Community Development Arrive am/pm Depart/ • am/,/ n/ Town of Queensbury Inspector's Initials - ( 742 Bay Road Queensbury,New York 12804 NAME A-C-1-01 ,P. PERMIT# F` — l v, LOCATION 17 8 L-&,o . Pr_ oL uvo ; DATE 1 //6 14c TYPE OF STRUCTURE N/A YES NO COMMENTS Chimney Height/"B"Vent/Direct Vent Location G '���,Vt t �C,I� Fresh Air Intake � Plumb Vent through roof Roof Complete Exterior Finish Complete Interior/Exterio '.:. ings 30"to 36" Exterior Han., .ils,ba onies,landing 18 in. or more tenor Han. ails stairs •.th sides 3 or more risers - Grade 2%a ay from fo 4 dation , 7 8"clearance o sill plate Gas alve s t-off e ►•sed/regulator 18"above grade Gas F h, .ce .hut •: within 30 feet or within line of site Oil Furna«• • •. -off at entrance to furnace area Furnace/Hot ater Heater operating Relief Valv-(s)installed Headroom,6 . 6 in. on stairs Basement star s,6 ft.4 in. Handrail exte .or stairs both sides more than 3 risers Interior privac /trirn/doors/main entrance 36" Floor Finish Bathroom/Kitc en watertight Interior Handra Is Balconies/Landing 18 in. or more Railing across window in stairwells • Smoke Detectors: every level every bedroom outside every bedroom inter connected Bathroom fans Plumbing fixtures Foundation insulation 3/4 hour fire door/door closer Garage fireproofing Garage penetrations sealed Furnace in separate room protected(in garage) Light ventilation per room Safety glazing 18"or less from floor Final Electrical / Site PlanNariance required Final Survey Plot Plan 1 � k /As Built Septic System layout r uired Okay to issue C/C(Certif. of Compliance) Okay to issue temp. C/O(Certif. of Occupancy) Okay to issue permanent C/O(Certif. of Occupancy) 8v /� TOWN OF QUEENSBURY _+' r�_�: BUILDING & CODE ENFORCEMENT .k,�.;� 742 BAY ROAD ' =- y QUEENSBURY NY 12804 (518) 761-8256GPI �! ARRIVE: DEPART: INSP: ^'AL FINAL INSPECTION REPORT - RESIDENTIAL DATE INSPECTION REQUEST RECEIVED: NAME \�,(.•¢-Cj7'EC'Je e r LOCATION 1 i 14)-a, P, is WO . — ` DATE ��V t, PERMIT H `(/( TYPE OF STRUCTURE FOOTINGS FOUNDATION BACKFILL FRAMING ROUGH PLUMBING SEPTIC _ INSULATION • FINAL ELECTRICAL _ WOODSTOVE OR FIREPLACE N/A YES NO CHIMNEY HEIGHT/B VEN .IGHT PLUMBING VENT ROOFING EXTERIOR FINISH DECK/PORCH/ PS ` .ILINGS RELIEF VALVES FURNACE/HOT NATE- OPERATING INTERIOR TRIM PNIVACY DOORS FINISH FLOORS: BATH/KITCHEN ATERTIGHT OTHER FLOORS SWEEPABLE OTHER FLOORS CARPETED STAIR CLEARANCE/RAILINGS SMOKE DETECTORS BATHROOM FANS PLUMBING FIXTURES FOUNDATION INSULATION GARAGE FIRE PROOFING DOOR CLOSERS FI AL ELECTRICAL ITE PLAN/VARIANCE REQ. A FINAL 1/SURVEY OT PLAN 1 OK TO ISSU Cl OR C/C . . 1 RESIDENTIAL FINAL INSPECTION REPORT -3 'PM Office No. (518)761-8256 Date inspection request received: �`.50 Building& Code Enforcemeut Dept. of Community Development Arrive am/pm Depart��am/ m Town of Queensbury Inspector's Initials _ 742 Bay Road Queensbury, New York 12804 (/ ' NAME %\ ( 1 (. \ PER/sin# /� l v LOCATION `7 g �, rfce, j IC DATE TYPE OF STRUJTURE N/A YES NO COMMENTS Chimney HeightP'B"Vent/Direct Vent Location Fresh Air Intake t�/ : / Plumb Vent through roof V/ Roof Complete V Exterior Finish Complete V77- Interior/Exterior Railings 30"to 36" Exterior Handrails,balconies,landing 18 in. or more Interior Handrails stairs both sides°3 or more risers - Cv t&' �� Grade 2%awayfrom foundation 2/9' �- RkJ i, 8"clearance to sill plate �' 4"tom A ,(� Gas Valve shut-off exposed/regulator 18"above grade / 02. Gas Furnace.shut-off within 30 feet or-with-in line of site J Oil Furnace shut-of at entran to furnace area Fumace/Hot Water Heater operating Relief Valve(s)installed If 1,17j7 Headroom,6 ft. 6 in. on stairs Basement stairs,6 ft.4 in Handrail exterior stairs both sides more than 3 risers Interior privacy/trim/doors/main entrance 36" V/ Floor Finish / Bathroom/Kitchen watertight ,/ Interior Handrails Balconies/Landing 18 in. or more / ../..' Railing across window in stairwells Smoke Detectors: 1.6 every level every bedroom outside every bedroom ✓/ inter connected Bathroom fans Plumbing fixturesIV/ Foundation insulation / 3/4 hour fire door/door closer ✓� Garage fireproofing V Garage penetrations sealed Furnace in separate room protected(in garage) Light ventilation per room I Safety glazing 18" r 1 ss from fl r9 Final Electrical `44 l'a ) V /V Site Planariance q • ed Final Survey Plot Plan As Built Septic System layout required Okay to issue C/C (Certif. of Compliance) Okay to issue temp. C/C)(Certif. of Occupancy) I Okay to issue permanent C/O(Certif. of Occupancy) GENERAL INSPECTION REPORT Town of Queensbury / cp Dept. of Community Development Date inspection request received: �/ /V3 Building& Code Enforcement 742 Bay Road ,�,'�, Queensbury,NY 12804 Arrive a m D part = ` spector's Initial• - goir NAME: MG1 /a s 41, ,, PERMIT# —�• 7 LOCATION: /7 8' C' x i & /31 ta-- DATE : / TYPE OF STRUCTURE: RECHECK N/A YES.I�O COMMENTS dotings/Piers cam' I G�`R D Monolithic Pour Form Reinforcement in Place 'VCR p� �U���U The contractor is respons'lle for gE VP� providing protection fro freezm_ F- r1-2E for 48 hours following e pla - rent (✓ \ of the concrete. Materials for this purpo -on site 4� ,��h _ Foundation!Wallpour A OD-- .4�' Reinforcement in Place Foundation/Dampproo' r g Backfill Approval Plumbing Under Slab Plumbing Vent/Vents in ''ace Rough Plumbing Heating Rough-In Insulation Foundation Walls Interior R- Foundation Walls Exterior R- Floors R- Walls R- Ceiling R- Duct work or piping in unheated spaces R- ' Proper Vent, Attic Vent Framing Jack Studs/Headers Bracing/Bridging Joist Hangers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1, 2, 3, hour Penetration Sealed Fire Wall 2, 3, 4 hour Firestopping I, 1 GENERAL INSPECTION REPORT Town of Queensbury Dept,of Community Development Date inspection request received: Buil rz'ng& Code Enforcement 742 Bay Road Queensbury,NY 12804 Arrive am/pm Depart/- ��a"�m/pm Inspector's Initials "�f✓ NAME: \, ltc',`c•s G PERMIT# 17 I lJ `I LOCATION: t78 quo6eJ.,3 P(. b LA)to DATE : G TYPE OF STRUCTURE: RECHECK N/A YES NO COMMENTS Footings/Piers, I Monolithic Dour Form Reinforcementin Place The contract is •8 nsible for providing pro - -',n from freezin for 48 hours foll►4► : the •1. - ent of the concrete. Materials for thi•purpose on site Foundation/Wa pour Reinforcemen. in Place Foundatio D•mpproofing Back ill ° roval PI bing I nder Slab umbin: Vent/Vents in Place Rough Plumbing tjA►c CI-or-T(6 Heating Rough-In Insulation Foundation Walls Interior R- Foundation Walls Exterior R- Floors R- Walls R- Ceiling R- Duct work or piping in unheated spaces R- Proper Vent, Attic Vent Framing Jack Studs/Headers Bracing/Bridging Joist Hangers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1, 2, 3, hour Penetration Sealed Fire Wall 2, 3, 4 hour Firestopping GENERAL INSPECTION REPORT Town of Queensbury Dept. of Community Development Date inspection request received: Building& Code Enforcement 742 •'ay Road ` Z Queensbury,NY 12804 Arrive am/pm Depart ' Sam/ m Inspector's Initials NAME: it 6I- S gte .- PERMIT# g LOCATION: pg VOLlJ DATE : TYPE OF STRUCTURE: RECHECK N/A S NO COMMENTS Footings/Piers Monolithic Pour Form Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site Foundation/Wallpour Reinforcement in Place Foundation/Dampproofing Backfill Approval Plumbing Under Slab Pjumbing Vent/Vents i Place /2 R Rough Plumbing 4I HG A5�1�4 L� Heating Rough-In Insulation 42/L1- L a 4-r -S Foundation Walls Interior R- Foundation Walls Exterior R- Floors R- [} � �Lt-tE C KN Walls R- Ceiling R- Duct work or piping in unheated spaces R- Proper Vent, Attic Vent Framing Jack Studs/Headers Bracing/Bridging Joist Hangers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1, 2, 3, hour Penetration Sealed Fire Wall 2, 3, 4 hour Firestopping GENERAL INSPECTION REPORT Town of Queensbury Dept.of Community Development Date inspection request received: Building& Code Enforcement 742 Bay Road , II Queensbury,NY 12804 Arrive am/pm Depart tI,c. am/pm Inspector's Initials NAME: 1/./t,LCi-frit-t, APP, PERMIT# 4..9- li IP LOCATION: j1 ki/0.5e A) ej. 64_vi3, DATE : et iiiv9# TYPE OF STRUCTURE: RECHECK N/A YES NO COMMENTS Footings/Piers F I Monolithic Pour Form Reinforcement in Place The contractor is responsible or providing pro - tion from :- ing for 48 hours follo *ng the p I cement of the concrete. Materials for this purpose • Foundation/Wallpour Reinforcement in Place Foundation/Dampproofing Backfill Approval P ' Bing Under Slab , - P mbing VentNents ip Place fl Iuim ough Plumbing Ajih t- ,/1/',)-7' d-4-0 7 Heating Rough-In Insulation Foundation Walls Interior R- Foundation Walls Exterior R- Floors R- Walls R- Ceiling R- Duct work or piping in unheated spaces R- Proper Vent, Attic Vent Framing Jack Studs/Headers Bracing/Bridging Joist Hangers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1, 2, 3, hour Penetration Sealed . Fire Wall 2, 3, 4 hour Firestopping GENERAL INSPECTION REPORT 1 Town of Queensbury Dept. of Community Development Date inspection request received: (12 V z29 Building& Code Enforcement 742 :,ay Road 9 ' Queensbury,NY 12804 Arrive am/pm Depart lbam/p Inspector's Initials NAME: G ,U - PERMIT# q9-/ g LOCATION-. Fa_ / /71ie/ DATE : /O =-1., �7/51> TYPE OF STRUCTURE: 7 RECHECK N/A YES NO COMMENTS Footings/Piers Monolithic Pour Form Reinforcement in Place \ The contractor is respo ible for providing pro tion fro freez' g for 48 hours fo owing e place ent of the concrete. Materials for this p se n • Foundation/Wallpour Reinforcement in Place Foundation/Dampproofin Backfill Approval lumbing Under Slab Plumbing Vent/Vents in lacer� ,, J 2 Rough,P1 bing jU M. c, f�.A�G6 S I f v�C,�— / V— J L A-T"& Heating Rough-In _ /sulanon 70 /"© ` Foundation Walls Interior R- Foundation Walls Exterior R- Floors R- Walls / R- �� J/ Ceiling R- /fl V Duct work or piping in unheated spaces R- iProper Vent, Attic Vent Fraining I// Jack Studs/Headers \/ Bracing/Bridging Joist Hangers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1, 2, 3, hour Penetration Sealed Fire Wall 2, 3, 4 hour Firestopping GENERAL INSPECTION REPORT Town of Queensbury Dept.of Community Development Date inspection request received: Building Code Enforcement 742 ;•ay Road ' Queensbury,NY 12804 Arrive am/pm Depart am/pm Inspector's Initials NAME: VA.kGs4*-t-5 Cvr , PERMIT# ?i"i LOCATION: DATE : '17'9c TYPE OF STRUCTURE: RECHECK N/A YES NO, COMMENTS Footings/Piers .--- Monolithic Pour Form �' Reinforcement in Place The contractor is responsible`for providing protection from ,;freezing for 48 hours following the placement of the concrete. Materials for this purpose on site Foundation/Wallpour Reinforcement in Place Foundation/Damppraofing . Backfill Approval t Plumbing Under Slab a Plumbing Vent/Vents in Place Rough Plumbing Heating Rough-In Insulation Foundation Walls Interior R- Foundation Walls Exterior R- Floors R- Walls R- Ceiling R- Duct work or piping in unheated spaces R- oper Vent, Attic Vent f 1 ��� 444 raming �/ �,' c f�tv� UPdq5 Jack Studs/Headers Bracing/Bridging Joist Hangers -1iR u 4 i A)-G `. CL Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1, 2, 3, hour Penetration Sealed Fire Wall 2, 3, 4 hour Firestopping . P n FIRE MARSHAL TOWN OF QUEENSBURY r QUEENSBURY, NY 12804 (518) 761-8205 FIRE MARSHAL INSPECTION REPORT REQUEST RECEIVED NAME ` ! Llitc „��1� �3�.�tn LOCATION PERMIT# SCHEDULE INSPECTION ON �-- I `11 AM PM APPROVED N/A YES NO EXITS AISLE WIDTHS. EXIT SIGNS EMERGENCY LIGHTING FIRE EXTINGUISHERS FIRE ALARM SYSTEM FIRE SPRINKLER SYST M FIRE SUPPRESSION S STEM HOOD INSTALLATION INTERIOR FINISHES STORAGE: CLEARANCE TO SPRINKLERS CLEARANCE TO HEATING UNITS REQUIRED SIGNAGE \ "CHIMNEY D q�l v /6r l WOOD STOVE FIREPLACE A MASONRY ❑FACTORY BLT. "OUGH-IN ❑FINAL REMARKS: OK TO THIS DATE J/f INSPSLIP.PUB INSPECTOR GENERAL INSPECTION REPORT Town of Queensbury Dept. of Community Development Date inspection request received: Building& Code Enforcement 742 .r ay Road Queensbury,NY 12804 Arrive am/pm Depart t Z am/p Inspector's Initials' NAME: \t _ �r� s� —, c \ PERMIT# LOCATION: \ • cam+ti kj ) DATE : — t TYPE OF STRUCTURE: RECHECK (.\ N/A YES NO COMMENTS Footings/Piers Monolithic Pour Form Reinforcement in Place The contractor is respo ible foi providing protection fro freezing for 48 hours following th=placement of the concrete. Materials for this purpose on s. Foundation/Wallpour Reinforcement in Place Foundation/Dampproofing Backfill Approval Plumbing Under Slab Plumbing Vent/Vents in Place 4-). eug1 Plumbing �-P1'L(- N 4-t c. fc_ Fug Heating Rough-In • Insulation Foundation Walls Interior R- Foundation Walls Exterior R- Floors R- Walls R- Ceiling R- Duct work or piping in unheated spaces R- Pro r Vent, i Venom ng �,-� �. ,/ �1Qcc�.EGE< ��,t�i)oG �ft-LL C,►v �d.� �Jrpu Jack Studs/Headers / Bracing/Bridging [�v5 �G �� out A- N Joist Hangers f ✓ Jack Posts/Main Beam _ Infiltration Barrier Fire Separation 1, 2, 3, hour Penetration Sealed � Fire Wall 2, 3, 4 hour l -/C6 t,A) OL , Firestopping GENERAL INSPECTION REPORT Town of Queensbury ept. of Community Development Date inspection request received: .:wilding& Code Enforcement 742 4.ay Road Queensbury,NY 12804 Arrive am/pm Depart a• - (")17 Inspector's Initials lP NAME: MKC i,2)( ( PERMIT# 99- - r�-s 1`O DATE : LOCATION: 1 ��' �U1� TYPE OF STRUCTURE: Th RECHECK N/A YES NO COMMENTS Footings/Piers Monolithic Pour Form Reinforcement in Place The contractor is re nsible fo providing protection om freezin for 48 hours followi the place nt of the concrete. Materials for this p se o Foundatio Reinforcement in PI Foundation/Dampproofing Backfl • :••roval__. � bing Under Slab C IRON [ L Ps(5c Plumbing Vent/Vents in Place Rough Plumbing Heating Rough-In I Insulation Foundation Walls Interior R- Foundation Walls Exterior R- Floors • R- Walls R- Ceiling R- Duct work or piping in unheated spaces R- Proper Vent, Attic Vent Framing Jack Studs/Headers Bracing/Bridging Joist Hangers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1, 2, 3, hour Penetration Sealed Fire Wall 2, 3, 4 hour Firestopping _, r TOWN OF QUEENSBURY BUILDING & CODE ENFORCEMENT 742 Bay Road Queensbury NY 12804 (518) 761-8256 SEPTIC DISPOSAL SYSTEM INSPECTION Name &CA Wili 6e1). Location UT- S-z 0o$o4) 6e Date �ql Permit # l' i ►S SOIL TYPE: Sand-Loam-Clay- Results of Percolation Test- (if applicable) Rat- Miiute/Inch TYPE OF YSTEM: ABSORPTI FIELD: total ength Length of .ch tre ch Depth of tre ches Size of stone SEEPAGE PITS: N -&T I Size - ft. x ft. Stone size PIPING: Size Type Bldg. to Tank Ta k to Dist. Box st. Box to Fief . 4Openings Sealed? No Partial LOCATION/SEPARATIi - Foundation to Tank feet yF undation to Abs.rption feet eparation of Pits _-�. eet Conforms as per Plot Plan Yes No LOCATION OF SYSTEM ON PROPERT : (circle one) Front - Rear - Left Side - Right Side Middle Front - Middle Rear COMMENTS: SYSTEM USE APPROVED: NO Arrived: Departed: Building Inspector . -• 'Y.-et tiftilp*Nriell-&--- --...;.: _:61e,..n.-C,_-,_-- - - - - __-_-.E.•,.., --__-_--: --_ ::-_:--- _ - . , • - -,- ----- 6*-1 ' 1 8" E 44./ 148 . 10' . 7 1... r 1 1 ,...,7/ i g cv , �51�� „�,,,,,, 3anlblv�ls r.„,,417 :Maui le a ' • la Muslop I . . V 17uswnoop NI uo UMcys i _ � " 4 ►" se pits�lqo Ile . iii ,. . 7 . . , VI = I MUSQ ia VIKIONO JO U9eS My G, / - \ . . . . r______FT ---------------7 i .. t0HJ g :: ."-i L. 4 : M • \ \ :., \ ; . • . 1,0 . 82 . . CO 1\ so. , _ sq it =5: CN .. .� l44 e -�� r 1 J II •,y f v di o < _.. __ ..A ���! _ RFC iskr:. \ . 3 . .D.,/_:(. .:7\ . \ , --Z- - \ z. /``2 mAy 10 4 19 9 1 �- `V TowN O' C�UEEt." BURY '�- `` ' BUILDiN C. AND ODE Jr� . \i_T.,:,.-s.', j • ' iiti i 1.-3 -• ,-.. 1........=_„.. , 4- 47,-, ,-. ..e ( L` t ? ,. Yr TOWN OF QUEENSBURY BUILDING & CODE ENFORCEMENT 742 Bay Road Queensbury NY 12804 (518) 761-8256 SEPTIC DISPOSAL SYSTEM INSPECTION Name X° Lo a io Dat Permit p\cv-w" 1( SOIL TYP Sand- oam-Clay- t1,6 Results of Percolation Test- (if applicable) Rate-- 'nute/Inch TYPE OF SYSTEM: ABSORPTION FIELD: 'otal Lengtfj 22 2 Length of each tr- ch \ # Depth . trenches , Size of tone \IL-1--(),,v SEEPAGE P—S: Nu ber- Size - f t. x ft. Stone size PIPING: Size Type Bldg. to Tank n 2j Tank to Dist. Box a Scp a a Dist. Box to Fi -ld/Pit Openings Seale? Yes lo Partial LOCATION/SEPA' ,,TIONS: Foundation to ank feet Foundation to bsorption 2.0' feet Separation of -"its feM Conforms as per Plot Plan Yes LOCATION OF SYSTEM ON PROPERTY: (circle .ne` Front - Rear - Left Side - Right Side Middle Front - Middle Rear COMMENTS: 4 A K- 4 L/AA SYSTEM USE APPROVED: YES / NO Arrived: Departed: -21,*. l D Building Inspector GENERAL INSPECTION REPORTCAttVf/ 1 1 Town of Queensb :ry Dept. of Community Development Date inspection request received: Bui➢i°ng& Code Enforcement 742 :,-ay Road Queensbury,NY 12804 Arrive am/pm Depart ' pm Inspector's Initials NAME: A PERMIT# LOCATION: 1 0 ,` (�-��.. 04�,`U(DATE : TYPE OF STRUtTURRE: RECHECK N/A YES NO COMMENTS Footings/Piers Monolithic Pour Form Reinforcement,in Place The contractor is responsible for providing protection from freez' g for 48 hours following the pla ment of the concrete. Materials for this purpose on sit Foundation/Wallpour Reinforcement in lace Fo etdation/Dam oofing kltfilIPAppirwal 1// Plumbing Under Slab Plumbing Vent/Vents in P1 e Rough Plumbing Heating Rough-In Insulation Foundation Walls Int nor R- Foundation Walls E erior R- Floors R- Walls R- Ceiling R- Duct work or piping in unheated spaces R- Proper Vent, Attic Vent Framing Jack Studs/Headers Bracing/Bridging Joist Hangers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1, 2, 3, hour Penetration Sealed Fire Wall 2, 3, 4 hour Firestopping GENERAL INSPECTION REPORT Town of Queensbury Dept.of Community Development Date inspection request received: Building& Code Enforcement 742 Bay Road Queensbury,NY 12804 Arrive /2i'{am/pm Depart am/pm ` Inspector's Initials /�' NAME: j 12 a, Gig,v PERMIT# 5.9 J , LOCATION: i l.r Ai, a- tow DATE : `farfilll TYPE OF STRUCTURE: RECHECK N/A YES/NO COMMENTS Footings/Piers Monolithic Pour Form `�/ CO-- c F,i Qvs Reinforcement in Place The contractor is responsible for ?al providing protection from freezing for 48 hours following a placement of the concrete. Materials for this purpose on ite Foundation/Wallpour \, Reinforcement in Place \ I Foundation/Dampproofing Backfill Approval \ 1 J Plumbing Under Slab f Plumbing Vent/Vents in Place / Rough Plumbing IHeating Rough-In Insulation I Foundation Walls Interior R- Foundation Walls Exterior R- Floors R- Walls R- / Ceiling R- Duct work or piping in unheated spaces R- Proper Vent, Attic Vent Framing Jack Studs/Headers Bracing/Bridging Joist Hangers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1, 2, 3,,hour Penetration Sealed Fire Wall 2, 3,4 hour Firestopping yL FIRE MARSHAL TOWN OF QUEENSBURY e' QUEENSBURY, NY 12804 7,4,-,,a'`.: (518) 761-8205 FIRE MARSHAL INSPECTION REPORT REQUEST RECEIVED NAME ( " \ . C CR)LAe LOCATION " Itt 0 u..J a SCHEDULE INSPECTION ON Tr- it7 ,,,,...n., APPROVED N/A YES NO EXITS AISLE WIDTHS EXIT SIGNS /� ~,\ EMERGENCY LIGHTING d \ re,' FIRE EXTINGUISHERS; --n FIRE ALARM SYSTEM/ FIRE SPRINKLER SYSTEM FIRE SUPPRESSION SYSTEM HOOD INSTALLATION INTERIOR FINISHES STORAGE: CLEARANCE TO SPRINKLERS CLEARANCE TO HEATING UNITS REQUIRED SIGNAGE CHIMNEY WOOD STOVE FIREPLACE ❑MASONRY ACTORY BLT. ErraH-IN L REMARKS: OK TO THIS DATE INSPSLIP.PUB INSPECTOR 0.4.J.. " 1,4-11. -A-J-11. "1/4-fil JILF • - /7 - ••••`•-- • . CONSERVATION CONSTRUCTION CODE PART 5 COMPLIANCE FORM ."1/•!? Building Design by Acceptable Practice .01, kJ- ;VED BUIL.DING API? 0 9 • ADDRESS: — 13 -PuLdwil 91- . DATE. Latvrt 11,.n, 1999 Bull. OUEENseun -1414-VAI 11 .a65V6eael . coUNnr: ARCHITECT,ENGINEER,OR corrrRAcroR: THE M1CHAEV2• &RoUP PHONE: 5 1 8-762€47&33 677-0 (e PERMIT APPLICANT: Sh Ale PHONE: I. HEATING DEGREE DAYS (Table 2-1) • ID 5000-6000 7000—9000 II. BUILDING DESCRIPTION (Pre-qualifying Conditions) If the building does not meet all of the following pre-qualifying conditions, Part 5 of the Energy Code may not be used. [ j Building is residential with one or two dwelling units. B Building is less than 5,000 gross square feet Eg Building is three stories or less in height . Ratio of glazing area to gross wall area is equal to or less than 17%. III. PROJECT TYPE • El New construction n Substantial renovation of existing building El Addition to existing building D Exempt(7810.6c) .,• 0.F • - . o-.Rtix, • -IV. HEATING SYSTEM TYPEIx t ' I,0 Gas-fired Ej- Oil-fired Heat pump Electric - Joint Sealing: 7814.10(i) . Joint Location I Sealant Type Specified I Plan/Spec_ Reference Windows Polycell Doors frames Weatherstripping PP 9' - Walls at roof/ceiling Pal yc'el l Walls at floors/found. Polycell Wall panels NSA - Utility entrance Weatherstripping Penetrations' Polycell Other - Other Air Infiltration Barrier: 7814.10(j) Location Required? Specified I Plan/Spec.Reference . Walls yes/no No-Cedar Siding Other yes/no • Fireplace: 7814.10(k), (m) Required I Specified Plan/Spec_Reference Outside combustion Yes- • air duct with damper. • Flue damper with max.20 cfm, or damper and non-combustible doors ` 'fir 20 c_f_m_ . Gas fireplace ignitionNo VI. HVAC PERFORMANCE: 7814.11 (Table 5-3) Equipment Minimum Performance Specified Performance Plan/Spec.Reference Furnace • 70% AFUE 90% • Boiler _ Heat pump I Central air conditioner 'vll. HVAC CONTROL_ 7$14.12 Temperature Control Required + Specified • Plan/Spec.Reference Thermostat each yes dwelling unit Shut off at each yes terminal unit Thermostat Required I Specified I Plan/Spec.Reference Minimum range Yes 45°F-85°F Deadband Yes range ?5° Automatic • Yes capability VIII. DUCT SYSTEMS: 7814.13 Category I Required Provided Plan/Spec.Reference Duct >_ 1"thick N/A in conditioned space insulation R-33 in uncondtioned space Transverse Sealed Yes joints • IX. VENTILATION SYSTEMS: 7814.14 System Type Required I Specified Plan/Spec.Reference Supply Damper at envelope Yes Exhaust Damper at envelope Yes Supply on/off switch I YPs Exhaust - on/off switch 'I Y e s 1 ' ' X. PIPING INSULATION: 7814:15 Piping Type Insulation I Provided Plan/Spec. Required. I Reference Heating distribution` >_ 1i " I N/A Service hot water** : >_ 34" I N/A `Does not apply to runouts_ `*Does not apply to piping with a diameter less than or equal to 3/4"inch. . • XI. SERVICE WATER HEATING: 7814.21 (Table 5-4) Performance Requirements Wa[er Heaters Minimum Specified Plan/Spec. Performance Performance Reference Storage EE. > .93 -.00132V I > .93 - Instantaneous N/A Pool N/A - Controls Category -Required Control Control Provided Plan/Spec. Reference System automatic control Yes System temp.setting range 140 degrees max.Pool heater IID N/A Pool heater on/off switch N/A Electric water heater separate switch N/A Gas/Oil water heater separate valve Yes XII. ELECTRICAL POWER: 7814.31 Category I Required ISpecified Plan/Spec. Reference Electric meters I Ea. dwelling unit I "es • , • EXTERIOk WALL OPAQUE FRAMED *ALL: VORK5HEE7 • R-Value Insulated i Construction R-Value Fran. Area _ Component f Area il'Aiiell. . ... ��• it. Air Film II/1J1ij- 0.68 ......... 0.68 .45 " I l 1 r. t . 1/2" Gypsum Bd. ; .45 1 1i i iI� 1 t`/: - ��� :;;:4; ::: ---- I --- 2x6 @ 16" o.c. 6.87 • /�. Studs t.1:‘*‘&1- 19.00 �•% fir I t .54 i I ll 111111= .. ... . 1�2 Sheathing •.54 . Al� • ilirM :65"... . • VlnySli di ng .65 ()) \O.17 f�. Ezt Air Film t 0.17 21.49 • R-Total I. 9.36 U insulated F w raction* Framed Fraction* { R-Total Insulated R-Total Framea U >iS * .15 21.49 9.36 = .056 e. * wall Stud Spacing Insulated Fraction Framed :Fraction 12" O.C. .E]' • .l7 16" 0. C. .85 .l5 .813 .12 • • • • EASEMENT/CELLAR WALLS: kORKSH£E- @ stairwells R-Value 1 R-Value with Ext. Construction . with Int. Insulation Components insulation ♦:., ` 0.17 Ext. Air Film { 0.17 • :� 2�j None1.• ,♦. • ♦♦♦ � � :ii--- i Exterior 'r i ni sh 0 . ►♦. ; ♦:•• . i 8" Poured L - ,♦,♦�. ♦♦ • Block (Concrete) ; . ..1.72.. : �.�o : s Core Insulation• f• .. .• 4.4 • 4: =� ♦{ 1 ♦ ��j • l ti'f any) a •.►4: r♦� I ' I- Iz R-max AA- ((�• Insulation tc. �♦;- •y♦t . .r_ - None - . 1,444 Interior Finish • )t• :♦♦.« •• ♦♦+ . - e— 0.68 I 1 nt Air Film • 0.68 °� (.- ►♦�. • R-Total /3 -37 1 U - w R-Total (I ml -07 /3.37- • Exposure Above Grade m 8 ~ Depth Below Grade 48 S -t < • • BASEMENT/CELLAR VALLS: eORKSHEE- ' R-Value R-Va1ee with Ext. Constructi o: with Int. Insulation ( Components Insulation 0.17 �♦♦i _) I-41 jExt. Air file ! 0.77 ♦e�*I ! None ►.�� • ���• a j Exterior finish ? - ►♦♦4 ♦♦4• ' (•1� i 8" Poured �•►d; ::• . Blocs (Concrete) ; , .',L_7z. ire:: ♦j� j 4 - Core Insulation • • l'. - ♦t: • ;T-rs ♦♦� ! (.f any) I = ._- �♦�• • 0•4- �� • fl. to•I .�♦�: 0 Vi Insulation 114 ♦♦ o - :♦:: I,~���� :; «— None ([. • • Interior finish 44' ( Int, kir Fiiiq —68 . • • _ •-I 1 • .♦.• 13.57 R-Tota1 1 U a • w R-Total - uw is la 13 .57 .C74 �. Exposure Above Grade - 8 N Depth Bel on Grade ' 48 ' f A. - • . A • 0PACUE FRAMED F.COR: KORKSNE_' , f� » i�I«� I ---,-- .. i try') 17r r :. : I hi 1 I\ ILU ., t:::::::-V 4 i ' ,.re'''-'''' 1.:( ' .....""--- ; ; 1 ',./.*; R-Value ' R-Value• , , I ' Insulated Construction ' f rasiea I Area Cc -ponents , - Area : i I ' I • i 0.92* 1 0.92* ' ' • Ext. Air Film 19,.00 . 6„ Batt ---- -- . . . . . Insulation • ---- � 11 7/8" TJI's @ 24" o.c' . ... Joists I 14.84 , I i 3/4" waferwcod 1 1 , .93 . .. . Sub-Floor ,.;;.93 n 1, carpet vinyl I ne9l 1... in. Floor I . 0.92 0.92 Int. Air Film 21.02 I R-Total I :16.86 U insulated Fraction** Framed fraction** o + R-Total insulated R-Total Framed u = .95- + .05 0 21.02 16.86 •e'.048 • * For vented crawl space, use R * 0.17 for ext. air film. ** Floor Joist Spacing Insulated Fraction Y Framed Fraction 12" 0.C. .87 .13 16" 0.C. .90 .10 r 24" O.C. .93 .07 i ROOF/CEILING (VENTED) : RORKSHEE: ---;.!/11//7-7--7-.7E:EE75 . --%i j''‘ si ,---f-------„--=--y: ,, . . R-Value R-Value I Insulated ' 1 Construction Framed Area i Components :.ref 1 i 0.7 7 i �Ext. Air Film 0.17 I 30.00 i 9" Batt ---- 12.00 Overlap- .... Insulati • on 2x4 bottom chord .� @ 24". oc 4.35 .... Joists I ; 1 _45 1/2" Gypsum Bd. .45 • Wallboard 0.61 Int. Air Film 0.61 I . • 31.23 R-Total i7_58 U Insulated Fraction* Framed Fraction* r R-Total •Insulated + R-Total Framed U .93 . .07 r • 31.23 17.58• =034 • * Roof Joist Spacing Insulated Fraction ' Framed Fraction 12" 0.C. .87• .73 16" 0.C. .90 .10 24" O.C. .93 .07 V. BUILDING ENVELOPE DATA: 7814.2 Envelope Component Minimum. Provided Plan/Spec. Required Reference Exterior wall R= 18. R= ls_ol .. Roof/ceiling R= 24 . R= 29.4 - Floor R= 19 • R= 30.5 Foundation wall R= 10 R= 13.57 • Slab edge insulation. R= to R= N/A GIazing - R= 1.7 R= 3.3 ' Entrance door R= 2.5 R= _ to Insulated depth below grade D= .48" D= 48" .1 Skylight R= 1.7 R= 3.8.. - - Skylight%of total roof area 1%Maximum %= < I le I Vapor Retarder: 7814.2(c) - Location Location Type Plan/Spec. Required Provided Provided Reference Walls Yes Poly Ceiling Yes Poly • Floor Yes 3/4" OSB .5 Perm "` Other 0 ; Infiltration Rate: 7814.2(h) EIement Maximum Rates I Rates Specified Plan/Spec.Reference Windows 0.37 cfm/lin. ft_ - I .12 Doors 0:50 cfm/sq.ft. I Patio .12 Swing .04 -----• „,\ /.:REPARED BY1 **. ' I PAGE . NO. DATE 1 1 \ / .:. . .... .. . ._ _ , . . . / • . - • /2',: 1 1 i t p....-. ...., .c..... ._47 •S' 0 • i i . i .'-- 'II -, G)0 . - It, rz, czt• '"e—rip5 , 1 Z C./ rri ...... ( . i •••• "...% j. ........... 0 4••• CO' ‹,........ . . i I 00 E.:51) co(r) nr, . . I LI - I ' • 41 i 177 X _ . i , ..< 0 -4. - i 1 • '' ... ! i ; c?...) ,.....) -......_ , , 1 . --..... _ (./ I C; •...0 ,1 1 . 1 I i i r 1 • ' ^-.2. (1\----- Z 1 i 1 1 -i :- / I - - " i ,.0.-..., , • . ' .:: . I "........... i CP'. 1 . .. ......, Z . . 1 --• j j \-..,-) i C• ..I , L ri. ----)1 L:1 • r. ST ....., C)'-') _ - ' .....- N._ —. . . , i _ . . . .. . 1 1; . I 1 • I 1 . - . . _ .. . • .i I s - I 1 ) .., i . i I I )7..;:i . f...4''' '';'1;' ir V -: 7' . •/;;' w:'• :' a 1 \ ,:, .„,,,,-,,,,,„ . . _ • . ...: t-Y<"-- \ —1 - { \.I .- hF.., 7 i , �`�] L1� • , 1 ,f"'.';4.''.;.".:.:-:•'._.•.1_1•'",4'''•',-,','',:'•,.'?..',=..?-',-'-.;`'.,.1,,'!,-..'.','b'-'.5;„5,-':.;.-,::;;':'*,:'X,',.:•4:,4,*."•rP.-: ,,-,*,: f, ice/ O •\ i . . . 41;'... , .: . --,;(,:.,,,;;F---,i; .. . tbs " .i.,.,:,,,,, e4. . is cn 7?i.›-S.c - \ R , 1. 00 ,g'i 1 Z2 , ,CYT_ . ; , co --: , .,,, .,, . , . . •.. .• . i . ' ' ----FI . h °A E� -E . r: 7.,..! 0") • , : . Z }. APR 0 9 1999 ,,,,, \• TOWN OF QUEENISSURY "' • BUILDING AND CODE s . tip "I have seen or obse , . 't 1 all objects such as hole+ , 4 . .. .. :. . shown on this document ti , .i • A T1 :: T! " E L _ -___ - L . 24;„ t. . . t. , , hii• • • 3 u9 tCL L. 9L • S - . - MAP REFERENCE: HUDSON POINTE P.U.D. PHASE II BY VAN DUSEN & STEVES DATED MAY 1994 LAST REVISED MARCH 7, 1996 FILED IN THE WARREN COUNTY CLERK'S OFFICE ON APRIL 16, 1996 AS INSTRUMENT NO. 44 PLAT CABINET B SLIDE 64 m • HUDSO� POINTS H.O.A. G EN SPACE 52.11' 768 l0 82 47,426 sq ft NN I HEREBY CERTIFY THAT THIS NAP WAS PREPARED FROM AN ACTUAL FIELD SURVEY. THIS CERTIFICATION SHALL RUN ONLY TO THE PERSONS FOR WHOM THE SURVEY WAS PREPARED. AND ON THEIR L _144 BEHALF TO THE TITLE COMPANY. GOVERNMENTAL AGENCY 13 AND LENDING INSTITUTION LISTED HEREON. R`SOC OD INSTITUTIONARE NOT TRANSFERABLE TO ADDITIONAL T OWMERS. TE BLVD • c�V° HUDSON P O I N f�F� ° >�� cERnFlED T0: Michael P. Marjorie L Brassel Glens Falls National Bank do Trust 3, Company. Its successors and/or assigns N69•�7 3 Chicago Title Insurance Company 6. • ` of NEWS ,s RECEIVED CERTIFIED BY: �V 4 JUL 15 1999 MATTHEW C. STEVES. LLS NYS 50135 ' Tfp: fly G AND CODE • • • , (AND ^� a�►. u ,S ate: L .1 I }� A�m+An�N art A 4E" m A war VOLANO � x � p " Map of a Survey made for Scale 1 "=30' Maass aP rmq ale-omra a, a ac NEW VOW STA 1:9=A1 1". & S t e v e r M6Y „E ORKINAL aNM NARIeD wiN OF TIE LAND WAtWYM sw_ awl et mot vALD nue wren• " "°C=MR°AW"V OM MICHAEL P. & MARJORIE L. BRASSEL S-1 "a SAWY PWAM N AOCOFA&- i WIN TA Land Surveyors, LLC "°I""°"'°°" �""�M'I° WW%. er D NEW suit Ass ION O rNaMM ON Y wa sAw eartorwsaNa oNAu ow oalr TO Re PONON rCR eMCN 1Nt WWA-f a PIePMM AND ON 37 Chester Street Glens Falls, New York 12801 'O AND "" Loa um "� AND TO � � ,� �` 1 7-14-99 DRIVEWAY Town of Queensbury, Warren County, New York �T I OF 1 (518) 792-8474 New York Lic. No. 50135 BRASSEL NO. DATE DESCRIPTION DWG. NO. HP-82