RC-0553-2022 This form must be filled out and posted to comply with building code requirements. Meets IRC Chapter 11 Energy Efficiency Requirements and IECC Chapter 4, Commercial Energy Efficiency Requirements. Consult International Building Code, Chapter 26-Plastic and International Residential Code (IRC) R316 Foam Plastics for specific requirements. The spray polyurethane foam insulation system(s) has/have been installed in accordance with manu- facturer’s processing guidelines to provide a thermal resistance of: The following spray polyurethane foam product(s) has/have been installed. Heatlok HFO PRO 2.0-2.4 lbs/ft³ IAPMO UES ER-0565 Heatlok HFO High Lift 2.0-2.4 lbs/ft³ ICC-ES ESR-4073 Heatlok XT High Yield (s) 2.23 lbs/ft³ ICC-ES ESR-3824 (w) 2.17 lbs/ft³ ICC-ES ESR-3883 Heatlok XT High Lift (s) 2.23 lbs/ft³ ICC-ES ESR-3824 (w) 2.17 lbs/ft³ ICC-ES ESR-3883 Foam-Lok 2000-4G 2.0-2.2 lbs/ft³ CCRR-1025 Foam-Lok 2000-3G 2.0-2.3 lbs/ft³ ICC-ES ESR-4501 Foam-Lok 2000 2.0-2.3 lbs/ft³ ICC-ES ESR-2629 Proseal HFO 2.0 lbs/ft³ CCRR-1108 Proseal LE 2.2 lbs/ft³ ICC-ES ESR-3500 Proseal 2.2 lbs/ft³ ICC-ES ESR-3500 Heatlok Eco 2.0 lbs/ft³ ICC-ES ESR-3198 Closed-Cell Spray Polyurethane Foam Insulation Certificate AN: 21.00132 | REV: 05.27.21 3315 E. Division Street, Arlington, TX 76011 Tel: 817.640.4900 | 888.224.1533 www.huntsmanbuildingsolutions.com Area Insulated Aged R-Value Thickness** Vented Attic Floor Area Sloped Ceilings / Cathedral Ceilings Walls (Location: ) Walls (Location: ) Floors (over an unheated crawl space) Crawl Space Perimeter Basement Walls Other (Location: ) R- R- R- R- R- R- R- R- At At At At At At At At inches inches inches inches inches inches inches inches **Nominal thicknesses are representative of field, spray-applied foam material. -Post Near Electrical Panel- Unvented Attic/Under Roof Deck Insulation R-At inches Jobsite Address: Building Contractor: HBS Contractor: Installed By: Phone: Date of Installation: 60 8.0" Mud Room 49 6.75" New Exterior walls_Rock Wool Floor 49 Min 23 Rim Joists.24 3.25" Duncan Cove Road Queensbury, NY_Orban Res.04 / 2023 Hilltop conStruction Co. ASF Insulation Inc.518.309.5141 ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report. Copyright © 2022 ICC Evaluation Service, LLC. All rights reserved. Page 1 of 6 www.icc-es.org | (800) 423-6587 | (562) 699-0543 A Subsidiary of the International Code Council ® ICC-ES Evaluation Report Reissued August 2022ESR-4073 This report is subject to renewal August 2023. DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION Section: 07 21 00—Thermal Insulation REPORT HOLDER: HUNTSMAN BUILDING SOLUTIONS, LLC EVALUATION SUBJECT: HEATLOK® HFO HIGH LIFT SPRAY FOAM INSULATION 1.0 EVALUATION SCOPE 1.1 Compliance with the following codes:  2021, 2018, 2015, 2012 and 2009 International Building Code® (IBC)  2021, 2018, 2015, 2012 and 2009 International Residential Code® (IRC)  2021, 2018, 2015, 2012 and 2009 International Energy Conservation Code® (IECC) Properties evaluated:  Surface-burning characteristics  Physical properties  Thermal resistance  Attic and crawl space installation  Water vapor transmission  Air permeability  Exterior walls in Types I through IV construction 1.2 Evaluation to the following green standard: 2008 ICC 700 National Green Building StandardTM (ICC 700-2008) 2.0 USES Heatlok® HFO closed cell spray foam is a spray-applied polyurethane foam plastic insulation used as a nonstructural thermal insulating material in all Types of construction under the 2018, 2015, 2012, and 2009 IBC; in Type V construction under the 2021, 2018, 2015, 2012 and 2009 IBC; and in dwellings under the IRC. The insulation is intended for use in wall cavities, floor/ceiling assemblies, the underside of on-grade slabs, or attics and crawl spaces when installed in accordance with Section 4.4. Under the IRC and 2021, 2018 and 2015 IBC, the insulation may be used as air-impermeable insulation when installed in accordance with Section 3.5. Under the 2018, 2015, 2012 and 2009 IBC, the insulation may be used in exterior walls of Type I, II, III or IV construction when used as described in Section 4.5. The attributes of the insulation have been verified as conforming to the provisions of ICC 700-2008 Section 703.2.1.1.1(c) as an air impermeable insulation. Note that decisions on compliance for those areas rest with the user of this report. The user is advised of the project-specific provisions that may be contingent upon meeting specific conditions, and the verification of those conditions is outside the scope of this report. These codes or standards often provide supplemental information as guidance. 3.0 DESCRIPTION 3.1 General: Heatlok® HFO product is a rigid, medium-density, spray- applied cellular polyurethane foam plastic insulation installed as a component of wall assemblies, ceilings, floors, crawlspaces and cavities of roofs. The foam plastic insulation is a two-component, closed-cell, one-to-one by volume spray foam system with a nominal density of 2.0 pcf (32 kg/m3). The insulation is produced in the field by combining a polymeric isocyanate (A component) with a polymeric resin blend (B component). The insulation components have a shelf life of six months when stored in factory-sealed containers at temperatures between 50ºF (10ºC) and 80°F (26ºC). The Heatlok® HFO product meets or exceeds the minimum requirements set forth in Section 2603.1.1 of the 2021 IBC. 3.2 Surface-burning Characteristics: Heatlok® HFO product, at a maximum thickness of 4 inches (102 mm) and a nominal density of 2.0 pcf (32 kg/m3), has a flame spread index of 25 or less and a smoke-developed index of 450 or less when tested in accordance with ASTM E84 (UL 723). There are no thickness limitations when insulation is covered by a code-prescribed 15-minute thermal barrier. ESR-4073 | Most Widely Accepted and Trusted Page 2 of 6 3.3 Thermal Resistance (R-values): Heatlok® HFO product has thermal resistance (R-value), at a mean temperature of 75ºF (24ºC), as shown in Table 1. 3.4 Vapor Permeance: Heatlok® HFO has a vapor permeance of 1.0 perm or greater and less than 10 perms when applied at a minimum of 1 inch (25.4 mm) thickness and may be used where a Class III vapor retarder is required by the applicable code. 3.5 Air Permeability: Heatlok® HFO foam plastic insulation, at a minimum 1-inch (25.4 mm) thickness, is considered air-impermeable insulation in accordance with 2021, 2018, 2015 and 2012 IRC Section R806.5 (2009 IRC Section R806.4) and 2021 and 2018 IBC Section 1202.3 (2015 IBC Section 1203.3) based on testing in accordance with ASTM E283. 3.6 Blazelok TBX or Fireshell® F10E Intumescent Coating: Blazelok™ TBX or Fireshell® F10E intumescent coating (see ESR-3997), manufactured by ICP Construction, is a one-component water-based liquid coating. The coating is supplied in 5-gallon (19 L) pails and 55-gallon (208 L) drums and has a shelf life of (1) year when stored in factory-sealed containers at temperatures between 45ºF (7ºC) and 95ºF (35ºC). 3.7 DC 315 Intumescent Coating: DC 315 intumescent coating (see ESR-3702), manufactured by International Fireproof Technology, Inc., is a water-based coating supplied in 5-gallon (19L) pails and 55-gallon (208L) drums and has a shelf life of one (1) year when stored in factory-sealed containers at temperatures between 50°F (10°C) and 80°F (24°C). 4.0 DESIGN AND INSTALLATION 4.1 General: Heatlok® HFO product must be installed in accordance with the manufacturer’s published installation instructions and this report. A copy of the manufacturer’s published installation instructions must be available at all times on the jobsite during installation. 4.2 Application: The insulation is spray-applied on the jobsite using equipment identified in the manufacturer’s published installation instructions. The Heatlok® HFO product must be applied when the ambient and substrate temperature is between 50ºF (10ºC) and 100ºF (38ºC). The insulation must not be used in areas that have a maximum service temperature greater than 180ºF (82ºC). The foam plastic insulation must not be used in electrical outlet or junction boxes or in continuous contact with rain or water. The substrate must be free of moisture, frost or ice, loose scales, rust, oil and grease, or contaminates that will interfere with adhesion of the spray foam insulation. The Heatlok® HFO product may be applied in passes having a maximum thickness of 61/2 inches (165 mm) per pass. When multiple passes are required, subsequent passes can be sprayed once the core temperature drops below 100ºF (37.7ºC). 4.3 Thermal Barrier: 4.3.1 Application with a Prescriptive Thermal Barrier: Heatlok® HFO insulation must be separated from the interior of the building by an approved thermal barrier of 1/2-inch- thick (12.7 mm) gypsum wallboard or an equivalent thermal barrier complying with and installed in accordance with the applicable code except where the installation complies with the requirements set forth in Section 4.3.2. When installation is within an attic or crawl space as described in Section 4.4, a thermal barrier is not required between the foam plastic and the attic or crawl space, but is required between the insulation and the interior of the building. There is no thickness limit when installed behind a code- prescribed thermal barrier except as noted in Section 4.4.2.1. 4.3.2 Application without a Prescriptive Thermal Barrier: Heatlok® HFO spray foam insulation may be installed without the prescriptive 15-minute thermal barrier or ignition barrier described in Section 4.3.1 or Section 4.4.1, respectively when installation is in accordance with the following: 4.3.2.1 The insulation must be covered on all surfaces with a fire protective coating at the minimum thickness set forth in Table 2. 4.3.2.2 The maximum installed thickness of the insulation must not exceed the thickness set forth in Table 2. 4.3.3 The coating must be applied over the insulation in accordance with the coating manufacturer’s instructions and respective ICC-ES evaluation report for the coating and this report. 4.4 Ignition Barrier – Attics and Crawl Spaces: 4.4.1 Application with a Prescriptive Ignition Barrier: When Heatlok® HFO insulation is installed within attics or crawl spaces where entry is made only for service of utilities, an ignition barrier must be installed in accordance with IBC Section 2603.4.1.6 and IRC Sections R316.5.3 and R316.5.4, as applicable, except when the installation is in accordance with Section 4.4.2. The ignition barrier must be consistent with the requirements for the type of construction required by the applicable code, and must be installed in a manner so that the foam plastic insulation is not exposed. The attic or crawl space area must be separated from the interior of the building by an approved 15-minute thermal barrier as described in Section 4.3.1. Heatlok® HFO insulation, as described in this section, may be installed in unvented attics in accordance with 2021, 2018, 2015 and 2012 IRC Section R806.5 (2009 IRC Section R806.4) or 2021 and 2018 IBC Section 1202.3 (2015 IBC Section 1203.3). 4.4.2 Application without a Prescriptive Ignition Barrier: Where the spray-applied insulation is installed in accordance with Section 4.4.2.1, the following conditions apply: a)Entry to the attic or crawl space is to only service utilities, and no storage is permitted. b)There are no interconnected attic or crawl space areas. c)Air in the attic or crawl space is not circulated to other parts of the building. d)Attic ventilation is provided when required by 2021 and 2018 IBC Section 1202.2 (2015, 2012 and 2009 IBC Section 1203.2) or IRC Section R806, except when air- impermeable insulation is permitted in unvented attics in accordance with the 2021 and 2018 IBC Section 1202.3 (2015 IBC Section 1203.3) or 2021, 2018, 2015 and 2012 IRC Section R806.5 (2009 IRC Section R806.4), as applicable. e) Under-floor (crawl space) ventilation is provided when required by 2021 and 2018 IBC Section 1202.4 [2015 IBC Section 1203.4 (2012 and 2009 IBC Section 1203.3)] or IRC Section R408.1, as applicable. ESR-4073 | Most Widely Accepted and Trusted Page 3 of 6 f)Combustion air is provided in accordance with International Mechanical Code® Section 701. 4.4.2.1 Application without a Prescriptive Ignition Barrier: In attics and crawl spaces, Heatlok® HFO insulation may be spray-applied to the underside of roof sheathing and/or rafters, and to vertical surfaces and the underside of floors as described in this section. The thickness of the foam plastic applied to the underside of the overhead surfaces (roof sheathing, rafters and the underside of floors) must not exceed 111/4 inches (286 mm). The thickness of the foam plastic applied to vertical surfaces must not exceed 71/4 inches (184 mm). The attic or crawl space must be separated from the interior of the building by an approved thermal barrier as described in Section 4.3.1. 4.4.3 Use on Attic Floors: Heatlok® HFO insulation may be installed at a maximum thickness of 111/4 inches (286 mm) between and over joists in attic floors. The Heatlok® HFO insulation must be separated from the interior of the building by an approved thermal barrier. 4.5 Exterior Walls of Type I, II, III and IV Construction Under the 2018, 2015, 2012 and 2009 IBC: 4.5.1 General: When used on exterior walls of Type I, II, III, and IV construction, the assembly must comply with Section 2603.5 of the 2018, 2015, 2012 and 2009 IBC and this section, and the Heatlok® HFO insulation must be installed at a maximum thickness described in Table 3. The potential heat of Heatlok® HFO insulation is 2300 Btu/ft2 (26 Mj/m2) per inch of thickness when tested in accordance with NFPA 259. 4.5.2 Specific Wall Assemblies: Wall assemblies complying with Section 4.5 must be as described in Table 3. 5.0 CONDITIONS OF USE The Heatlok® HFO spray foam insulation described in this report complies with, or is a suitable alternative to what is specified in, those codes listed in Section 1.0 of this report, subject to the following conditions: 5.1 The products must be installed in accordance with the manufacturer’s published installations instructions, this evaluation report and the applicable code. If there are any conflicts between the manufacturer’s published installation instructions and this report, this report governs. 5.2 The insulation must be separated from the interior of the building by an approved thermal barrier, except when installation is as described in Sections 4.3.2 and 4.4.2. A thermal barrier must be installed between the insulation and the interior space above (crawl space) or below (attic). 5.3 The insulation must not exceed the thicknesses noted in this report based upon the intended end use. 5.4 The insulation must be protected from exposure to weather during and after application. 5.5 The insulation must be applied by contractors authorized by Huntsman Building Solutions, LLC. 5.6 Use of the insulation in areas where the probability of termite infestation is “very heavy” must be in accordance with 2021, 2018, 2015, and 2009 IBC Section 2603.8 (2012 IBC Section 2603.9) or IRC Section R318.4, as applicable. 5.7 When use is on exterior walls of buildings of Types I, II, III, and IV under the 2018, 2015, 2012 and 2009 IBC, construction must be as described in Section 4.5. 5.8 Under the 2021 IBC, use of Heatlok® XT-s closed cell spray foam insulation on exterior walls of buildings of Types I, II, III, and IV Construction is outside the scope of this evaluation report. 5.9 Installation in unvented attics, when equipped with vapor diffusion ports in accordance with Section 1202.3, Item 5.2 of the 2021 IBC and Section R806.5, Item 5.2 of the 2021 and 2018 IRC, is outside the scope of this report. 5.10 Jobsite certification and labeling of the insulation must comply with 2021, 2018 or 2015 IRC Sections N1101.10.1 and N1101.10.1.1 (2012 IRC Sections N1101.12.1 and N1101.12.1.1 or 2009 IRC Sections N1101.4 and N1101.4.1) and 2021, 2018, 2015 and 2012 IECC Sections C303.1.1, C303.1.1.1, R303.1.1 and R303.1.1.1 (2009 IECC Sections 303.1.1 and 303.1.1.1), as applicable. 5.11 The insulation components A and B are produced in Arlington, Texas and Boisbriand, Quebec, Canada, under a quality control program with inspections by ICC-ES. 6.0 EVIDENCE SUBMITTED 6.1 Data in accordance with the ICC-ES Acceptance Criteria for Spray-applied Foam Plastic Insulation (AC377), dated April 2020 (editorially revised July 2020), including reports of tests in accordance with AC377 Appendix X. 6.2 Reports of air leakage testing in accordance with ASTM E283. 6.3 Reports of water vapor transmission test in accordance with ASTM E96. 6.4 Reports of room corner tests in accordance with NFPA 286. 6.5 Reports of fire propagation characteristics tests in accordance with NFPA 285. 6.6 Reports of potential heat of foam plastic tests in accordance with NFPA 259. 6.7 Supplementary fire engineering analysis. 7.0 IDENTIFICATION 7.1 Components of the insulation are identified with the manufacturer’s name [Huntsman Building Solutions, LLC], address and telephone number; the product name (Heatlok® HFO B-side or A-PDMI); use instructions; the density; the flame-spread and smoke- developed indices; the date of manufacture; thermal resistance values; and the evaluation report number (ESR-4073). The ICP Construction, Blazelok™ TBX or Fireshell® F10E intumescent coating and primer is identified with the manufacturer’s name, the product name, use instructions and ICC-ES evaluation report number ESR-3997. The International Fireproof Technology, Inc. / Paint To Protect, Inc. DC 315 intumescent coating is identified with the manufacturer’s name, the product trade name, use instructions and ICC-ES evaluation report number ESR-3702. 7.2 The report holder’s contact information is the following: HUNTSMAN BUILDING SOLUTIONS, LLC 3315 EAST DIVISION STREET ARLINGTON, TEXAS 76011 (817) 640-4900 info@huntsmanbuilds.com www.huntsmanbuilds.com ESR-4073 | Most Widely Accepted and Trusted Page 4 of 6 T ABLE 1—THERMAL RESISTANCE (R-VALUES) THICKNESS (inches) R-VALUE (°F.ft2.h/Btu) THICKNESS (inches) R-VALUE (°F.ft2.h/Btu) 1.0 6.3 7.0 52 1.5 10 7.5 56 2.0 14 8.0 60 2.5 18 8.5 64 3.0 22 9.0 67 3.5 26 9.5 71 4.0 30 10.0 75 4.5 34 10.5 79 5.0 37 11.0 82 5.5 41 11.5 86 6.0 45 12.0 90 For SI: 1 inch = 25.4 mm; 1°F.ft2.h/Btu = 0.176 110°K.m2/W. 1R-values are calculated based on tested K-values at 1- and 4-inch thicknesses. TABLE 2—USE OF INSULATION WITHOUT A PRESCRIPTIVE THERMAL BARRIER (TESTED IN ACCORDANCE WITH NFPA 286) INSULATION TYPE MAXIMUM THICKNESS (in.) (Vertical Surfaces) MAXIMUM THICKNESS (in.) (Overhead Surfaces) COATING TYPE & MINIMUM THICKNESS2,3 (Applied to all Foam Surfaces) MINIMUM APPLICATION RATE OF COATING2 Heatlok HFO 71/2 111/2 Blazelok TBX or Fireshell® F10E 18 mils WFT 12 mils DFT 1.2 gal / 100 ft2 Heatlok HFO 71/2 111/2 DC 315 18 mils WFT 12 mils DFT 1.125 gal / 100 ft2 For SI: 1 inch = 25.4 mm; 1 mil = 0.0254 mm; 1 gallon = 3.38 L; 1 ft2 = 0.93 m2. Notes: 1See Section 4.3.2. 2DFT = Dry Film Thickness; WFT = Wet Film Thickness 3See Sections 3.6 and 3.7. ESR-4073 | Most Widely Accepted and Trusted Page 5 of 6 T ABLE 3—NFPA 285 COMPLYING EXTERIOR WALL ASSEMBLIES – WALL CAVITY INSULATION 1,2 WALL COMPONENT MATERIALS Base Wall System – Use either 1, 2 or 3 1 – Concrete wall. 2 – Concrete masonry wall. 3 –Minimum 35/8-inch-deep (92 mm), No. 25 gage, C-shaped steel studs, spaced a maximum of 24 inches on center with lateral bracing every 4 feet (1219 mm) as required by code. Interior sheathing must be 1 layer 5/8-inch- thick (19.1 mm) Type X gypsum wallboard complying with ASTM C1396. Exterior Sheathing shall be a described in Exterior Sheathing below. Floorline Firestopping Minimum 4 pcf mineral wool in each stud cavity at each floorline, attached with Z-clips. Thickness must match stud cavity depth. Perimeter Fire Barrier System Perimeter fire barrier system complying with 2018, 2015 and 2012 IBC Section 715.4 (2009 IBC Section 714.4) must be installed to fill the void between the edge of the concrete floor slab and the interior surface of the exterior wall assembly. Cavity / Interior Insulation –Use either 1, 2, 3, 4 or 5; (Note: Cavity Insulation No. 3 may be combined with No. 4 or Cavity Insulation No. 3 may be combined with No. 5 to achieve depth of insulation required) 1 – None. 2 – 35/8 inches (92 mm) of Heatlok® HFO applied to the interior surface of Base Wall System 1 or 2a. 3 – Full cavity depth not exceeding 35/8 inches (92 mm) of Heatlok® HFO. 3 – Any insulation qualified as noncombustible in accordance with ASTM E136. 4 – Glass fiber batt insulationb. 5 – Mineral fiber insulationb. a Fireblocking in accordance with 2018, 2015 and 2012 IBC Section 718 (2009 IBC Section 717) and thermal barrier material requirements in accordance with IBC Section 2603.4 shall be met for Base Wall Systems 1 and 2, when a combustible concealed space is present on interior side of the exterior wall assembly. b Insulation must comply with the applicable requirements of 2018, 2015 or 2012 IBC Section 720.2 (2009 IBC Section 719.2). Exterior Sheathing – Only for Base Wall System No.3 – Minimum 5/8-inch-thick (19.1 mm) glass mat gypsum sheathing complying with ASTM C1177. Sheathing shall be attached with No. 6, 11/4-inch-long (32 mm) self-tapping screws located 8 inches (203 mm) on center along the perimeter and 12 inches 302 mm) on center in the field of wallboard. Joints must be taped and treated with joint compound in accordance with ASTM C840 or GA-216. Exterior Wall Covering – Use either 1 or 2 1 – Any noncombustible exterior wall covering material using any standard installation technique (Base Wall 1 or 2) 2 – Any noncombustible exterior wall covering system with a combustible WRB that has successfully been tested in accordance with NFPA 285. (Base Wall 3) Details of the exterior wall covering must be provided to the code official by the report holder, designer or specifier, with an engineering analysis demonstrating that (1) the exterior wall covering conforms to ASTM E136 and (2) the addition of the wall covering and/or water-resistive barrier to the assembly described in this section does not negatively affect conformance of the assembly with the requirements of IBC Section 2603.5. 1 When used on exterior walls of Types I, II, III or IV construction, the specific wall assembly must comply with 2018, 2015, 2012 and 2009 IBC Section 2603.5. 2 The exterior wall assemblies described in Table 3 comply with 2018, 2015, 2012 and 2009 IBC Section 2603.5.5. ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report. Copyright © 2022 ICC Evaluation Service, LLC. All rights reserved. Page 6 of 6 ICC-ES Evaluation Report ESR-4073 CBC, CRC and CEC Supplement Reissued August 2022 This report is subject to renewal August 2023. www.icc-es.org | (800) 423-6587 | (562) 699-0543 A Subsidiary of the International Code Council ® DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION Section: 07 21 00—Thermal Insulation REPORT HOLDER: HUNTSMAN BUILDING SOLUTIONS, LLC EVALUATION SUBJECT: HEATLOK® HFO HIGH LIFT SPRAY FOAM INSULATION 1.0 REPORT PURPOSE AND SCOPE Purpose: The purpose of this evaluation report supplement is to indicate that the Heatlok® HFO High Lift Spray Foam Insulation, described in ICC-ES evaluation report ESR-4073, has also been evaluated for the codes noted below. Applicable code editions:  2019 California Building Code (CBC) For evaluation of applicable chapters adopted by the California Office of Statewide Health Planning and Development (OSHPD) AKA: California Department of Health Care Access and Information (HCAI) and the Division of the State Architect (DSA), see Sections 2.1.1 and 2.1.2 below.  2019 California Residential Code (CRC)  2019 California Energy Code (CEC) 2.0 CONCLUSIONS 2.1 CBC and CRC: The Heatlok® HFO High Lift Spray Foam Insulation, described in Sections 2.0 through 7.0 of the evaluation report ESR-4073, complies with the 2019 CBC and CRC, provided the design and installation are in accordance with the 2018 International Building Code® (IBC) and 2018 International Residential Code® (IRC) provisions noted in the evaluation report. 2.1.1 OSHPD: The applicable OSHPD Sections and Chapters of the CBC are beyond the scope of this supplement. 2.1.2 DSA: The applicable DSA Sections and Chapters of the CBC are beyond the scope of this supplement. 2.2 CEC: The Heatlok® HFO High Lift Spray Foam Insulation, described in Sections 2.0 through 7.0 of the evaluation report ESR-4073, complies with the 2019 CEC, provided the design and installation are in accordance with the 2018 International Building Code® (IBC) provisions noted in the evaluation report. 2.2.1 Conditions of Use: In accordance with Section 110.8 of the 2019 California Energy Code, verification of certification by the Department of Consumer Affairs, Bureau of Household Goods and Services, must be provided to the code official, demonstrating that the insulation conductive thermal performance is approved pursuant to the California Code of Regulations, Title 24, Part 12, Chapters 12-13, Article 3, “Standards for Insulating Material.” Certification can be verified with the DCA Bureau of Household Goods and Services using the following link to the bureau’s Directory of Certified Insulation Materials: https://bhgs.dca.ca.gov/consumers/ti_directory.pdf This supplement expires concurrently with the evaluation report, reissued August 2022. omim����um��moioi�uuuu««<titititititititiU111111V��llll�li1111�111��1�11�1�u ooiiu��� ������ �illl�i��� IIIIIIIIIIIIIIIIIIIII@u�" ����IIII0� IIIIIIIIIIIIIIIIIIIIIVi II m ����� �577�111�IIIIIIII�I �����„ IIIIII SUL-A-TION 100 MADISON DR STE 4, BALLSTON SPA, NY 12020 ........................................................................................................................................... November 9 2023 Hilltop Construction Company 233 Cleverdale Rd, Queensbury, NY 12804 RE: Blower Door Test for NYS Building Code, Tom Albrecht, After inspection of the 2 Story Home at 233 Cleverdale Road, Queensbury, NY and completion of a Blower Door Test consistent with the practice of depressurization to 50 Pascal in a winter condition with the exterior windows and doors shut and the interior doors to all the rooms open, my observations are as follows: ❖ This home tested passed the current New York State Building Code for Air Changes per Hour @ 50 Pascal of less than or equal to 3 ACH/50 (for Homes permitted after November 1", 2016). The tested number is 1.89 ACH/50 Pascal. ❖ The total volume of conditioned space at 233 Cleverdale Road is 48154.4 cubic feet taking into consideration all conditioned space in the home. The cubic feet per minute @ 50 Pascal was 1517 CFM/50. The height correction factor for New York State is 14 for a two-story building, as such the tested home @ 233 Cleverdale Road, has the natural rate of air exchange of 0.1350121395 air changes per hour/natural or 108.3 cfm natural air infiltration credit based on the blower door test. ❖ In the latest(2022)version of ASHRAE 62.2, high-performance homes need to be ventilated at 7.5 cfm per bedroom+ 1, plus 1 cfm per 100 square feet of living space. That means for 4+1 bedrooms it would need 3472 sq ft/100 times 1 cfm= 34.7 cfm + 37.5 cfm or 72.2 cfm total. Since the natural air flow of 108.3 cfm is more than the minimum requirement there is no necessity for continuous mechanical ventilation. It is still advantageous to use the kitchen and/or bathroom fans to help control humidity and improve indoor air quality during the heating season. ❖ My credentials are as follows: ➢ BPI Certified Building Analyst ➢ BPI Certified Envelope Specialist ➢ BPI Certified Heating Professional ❖ If you have any questions regarding my findings, please feel free to contact me. Sincerely, jack raw n& Cell: 518-410-1032 Email: jack@advancedsprayfoam.net 100 Madison Drive Suite 4 Ballston Spa, NY 12020 Phone: (518) 309-5141