SILO GARDENWORLD COMPLETE SUBMISSION updated STORMWATER MANAGEMENT SUMMARY 1.0 PROJECT DESCRIPTION The project consists of the construction of a new parking addition to the north of the existing rear parking area of the Silo Restaurant & Gift Shop. The project proposed is to incorporate a residential parcel to the north into the existing parcel to accommodate overflow parking for the existing commercial facility. There is no proposed increase of the existing commercial use operating hours or facilities. Also associated with the project is demolition of the existing residential structure / accessory buildings, landscaped buffer and stormwater management. The parcels are a 0.32 acre developed existing residential lot and a 0.77 acre developed existing commercial lot. Project disturbance totals 0.33-acres. 2.0 EXISTING SITE CONDITIONS The project site is mostly on the existing residential parcel which has a driveway (west side), house, covered deck and a patio(east side) of the parcel, the central portion of the parcel is a slightly sloping (west to east) grassed lawn area which has a retaining wall running north-south along the east section and partially along the southwest corner of the south boundary. The runoff from the front half of the roof and driveway runs east to west and discharges to the town road, the rear house roof, covered deck and patio runoff flows to the east and is captured in the lawn area in a depression in the lawn along the retaining wall and infiltrates into the soils. The eastern most portion of the parcel is gravel and grassed area that has three accessory buildings. The runoff from this area flows to the southeast corner of the parcel and reaches an existing drywell on the commercial parcel. Site slopes generally range from 2-4% from the west to east. Site soils are mapped as Hinckley Cobbly Sandy Loam, HSG-A which are deep, well drained sandy soils on outwash plains. A deep soil test pit performed for a previous project encountered fine and medium sands. Existing Conditions Summary Total Project Site Area: 1.09 Acres (combined) Building & Porch Coverages: 9,010 SF Walks, Drives & Parking Areas: 28,780 SF Total Impervious: 43,285 SF Drainage design points The site is broken into four drainage design points. Design point 1 is the southern portion of the existing commercial use which flows from the northwest entrance to the southeast entrance and drains to an existing trench drain. Design point 2 is the north portion of the existing commercial use and the east portion of the residential parcel which flows to the east and collects in the existing drywell. Note that during the 50 yr storm the runoff from this area exceeds the capacity of the drywell and ponds in the existing parking area until it eventually infiltrates into the drywell soils. Design Point 3 is the central east portion of the residential lot which flows from the east half of the house roof to the lawn depression along the retaining wall. Design point 4 is the west side of the residential parcel which the west portion of the house roof and driveway runoff and discharge onto the Town Road. 3.0 PROPOSED DEVELOPMENT Proposed Conditions Summary Total Project Site Area: 1.09 Acres Building & Porch Coverages: 6,450 SF Asphalt Parking & Permeable Asphalt Parking Areas: 34573 SF Total Impervious: 41,023 SF Project Disturbance: 0.33 Acres 4.0 PROPOSED STORMWATER MANAGEMENT As this is a commercial project with soil disturbances not exceeding 1-acre, NYSDEC SPDES requirements for stormwater discharges from construction activities do not apply to the project. The Town of Queensbury requires that commercial projects must implement stormwater management practices designed to manage the 50-year design storm event. Runoff from the south portion of the parcel will not be modified as no disturbance in this area is proposed. Runoff from the new parking addition will be directed to a new catchbasin in the southeast corner of the new parking area and discharge into a new stormwater subsurface infiltration trench. The new trench will be a 20 ft by 41 ft stone trench with 15 Cultec XL330 chambers in 3 rows of 5 chambers. The existing drywell will be connected to the new catchbasin with 12” HDPE piping allowing the existing drywell to discharge into the new infiltration trench. The permeable pavement infiltration was not included as part of the stormwater calculations. Design points 3 will be eliminated as part of the proposed work as the new parking area will discharge directly into design point 2. Design point 4 will also be eliminated as the landscaped area and parking area will discharge runoff to design point 2. An infiltration rate of 100-inches per hour is utilized for the infiltration facilities. Runoff calculations have been prepared utilizing SCS TR-20 methodology and HydroCAD analysis software for the 50-year Type-II simulated rainfall distributions. Criteria utilized in the analysis are summarized as follows: The developed site has been modeled as a series of subcatchments (drainage areas) and ponds, as shown on the HydroCAD drainage diagram. Full results of stormwater runoff computations are attached to this report. 5.0 TOWN OF QUEENSBURY REQUIREMENTS The Town of Queensbury requires that for commercial projects, the 50-year design storm event be evaluated. Existing 50-year peak storm volume: 0.182 AF Developed 50-year peak storm volume: 0.172 AF Existing 50-year peak storm discharge: 3.57 CFS Developed 50-year peak storm discharge: 3.40 CFS The 50-year storm calculations show that the Town's requirements for commercial projects are met. Gas ValveGas Test ValveGas Test ValveAsphalt ParkingAsphalt ParkingWood DeckSiloConcrete Pad with OverhangSignConcrete SidewalkSS-MHConcrete8'X4'Ø DRYWELLSign - No Parking To CornerStopSign30MPHSignSSSign"Center Lane Only"CBDrainage GrateNG9-1NG9-2U.P.U.P.U.P.IRFIPF2 StoryWood FrameBuildingLands N/F ofAftab BhattiLands N/F ofHarry Troelstra43.0'45.6'48.0'42.2'150.37'N 76°37'20" W50.50'N 37°13'10" W145.91'N 05°57'00" E S 80°34'00" E184.05'S 05°58'00" W 191.00'PARCEL 302.5-1-50Area=33353.0± SF0.77± AcresCedar RowCedar RowCedar Row Cedar Row 6.0'A/C14" Spruce14" Maple20" MapleShedPatioCovered DeckShedShedOne Story WoodFrame HouseIPFIPF4" TreeN 05°57'00" E75.00' 75.00' S 05°58'00" W S 80°34'00" E184.07'Adjoining HousePorchBilco Lands N/F ofBradley R PatchLands N/F ofBurns FamilyTrustTimber Retaining WallRetaining WallRetaining WallCrushed Stone8.2'8.1' 1.4'PARCEL 302.5-1-49Area=13779.1± SF0.32± AcresRim=97.76'FF=98.59'Elev.=98.51'FF=98.66'Rim=96.41'AdjoiningBuildingBM at HydrantBolt at ArrowElev.=104.91'Rim=100.05'100100100100 959595 95 9595 959595959595 11-EXISTING SPACES8-EXISTING SPACES8-EXISTING SPACES 11-EXISTING SPACES7-EXISTING SPACES7-EXISTING SPACES9-EXISTING SPACES9-EXISTING SPACES14-EXISTING SPA C E S 14-EXISTING SP A C E S 3-EXISTING SPACES3-EXISTING SPACES3-EXISTING SPACES3-EXISTING SPACES +101+9975' FRONT SETBACK75' FRONT SETBACK75' FRONT SETBACK25' REAR SETBACK25' REAR SETBACK25' REAR SETBAC K 25' REAR SETBAC K 25' SIDE SETBACK25' SIDE SETBACK25' SIDE SETBACK25' SIDE SETBACK30' REAR SETBAC K30' REAR SETBAC K 30' FRONT SETBACKMDR ZONE(MODERATE DENSITY RESIDENTIAL)CI ZONE(COMMERCIAL INTENSIVE)MDR ZONE(MODERATE DENSI T Y R E S I D E N T I A L ) CI ZONE (COMMERCIAL INT E N S I V E )CB-1107.0'107.0'Call Before You DigWait The Required TimeConfirm Utility ResponseRespect The MarksDig With Care800-962-7962www.digsafelynewyork.comDigSafely.New YorkGRAPHIC SCALESITE PLANSITE DEVELOPMENT DATAPARCEL 302.5-1-49LOT AREA:0.32-ACRES / 13,779 SFEXISTINGIMPERVIOUS AREASMAIN BUILDING1,475 SFACCESSORY STRUCTURES440 SFDECK, PORCH & PATIO645 SFDRIVE AREAS3,535 SFTOTAL IMPERVIOUS6,095 SFPERCENT IMPERVIOUS44.2%PERMEABILITY55.8%LOCATION MAPSITE LOCATIONMAP REFERENCES:SITE SETBACKSPARCEL 302.5-1-50REQUIRED FORCI ZONEEXISTINGFRONT(QUAKER ROAD)75'45.6'FRONT(CARLTON DRIVE)75'48.0'REAR (NORTH)25'42.2'REAR (EAST)25'43.0'NEIGHBORHOOD MAPSITE LOCATIONZONING REGULATIONSMDR - MODERATE DENSITY RESIDENTIALTAX MAP NO. 302.5-1-49MINIMUM LOT SIZE = 1-ACREFRONT SETBACK = 30'SIDE SETBACKS = 25'REAR SETBACK: = 30'SHORELINE = 75'MAX BUILDING HEIGHT = 40'LOT WIDTH = 100'ROAD FRONTAGE = 100'PERCENT PERMEABLE = 50%PARKING REQUIREMENTSCOUNTRY STOREFOOD SERVICE:TOWN OF QUEENSBURY REQUIREMENT:1 SPACES PER 4 SEATS100 SEATSSPACES REQUIRED: 25RETAIL BUSINESS:TOWN OF QUEENSBURY REQUIREMENT:5 SPACES PER 1000 SF OF RETAIL AREARETAIL SPACE: 5000 SFSPACES REQUIRED: 25TOTAL SPACES REQUIRED: 50ADA ACCESSIBLE DESIGN STANDARDS:NO. OF SPACES: NO. OF ACCESS. SPACES:1-25126-50251-75376-1004101-1255TOTAL ACCESSIBLE SPACES:4TOTAL SPACES PROVIDED:55SITE DEVELOPMENT DATAPARCEL 302.5-1-50LOT AREA:0.77-ACRES / 33,353 SFEXISTINGIMPERVIOUS AREASMAIN BUILDING6,210 SFDECK & PATIO240 SFDRIVE AREAS25,245 SFTOTAL IMPERVIOUS31,695 SFPERCENT IMPERVIOUS95.0%PERMEABILITY5.0%ZONING REGULATIONSCI - COMMERCIAL INTENSIVETAX MAP NO. 302.5-1-50MINIMUM LOT SIZE = 1-ACREMINIMUM LOT ROAD FRONTAGE = 50'MINIMUM LOT WIDTH = 150'MAXIMUM BUILDING HEIGHT = 40'FLOOR AREA RATIO = 0.3FRONT SETBACK = 75'SIDE SETBACK = 20' (50' TOTAL)REAR SETBACK = 25'PERCENT PERMEABLE = 30%SITE SETBACKSPARCEL 302.5-1-49REQUIRED FORMDR ZONEEXISTINGFRONT(CARLTON DRIVE)30'28.1'SIDE(NORTH)25'8.2'SIDE(SOUTH)25'6.0'REAR (EAST)30'107.0'ACCESSORY STRUCTURESTO BE REMOVEDEXIST. HOUSETO BE REMOVEDEXIST. CURB-CUTTO BE REMOVEDEXISTING CONDITIONS & DEMO PLANprepared for:Garden World Associates LLC537 Aviation Road - State Rt. 254 & 2 Carlton DriveTown of Queensbury, County of Warren, State of New YorkTAX MAP #'s 302.5-1-49 & 50Call Before You DigWait The Required TimeConfirm Utility ResponseRespect The MarksDig With Care800-962-7962www.digsafelynewyork.comDigSafely.New YorkHutchins Engineering PLLC291268-01-S2SITE DEVELOPMENT DATACOMBINED PARCEL 302.5-1-49 & 50LOT AREA:1.09-ACRES / 47,132 SFEXISTINGIMPERVIOUS AREASMAIN BUILDING7,685 SFACCESSORY STRUCTURES440 SFDECK, PORCH & PATIO885 SFDRIVE AREAS28,780 SFTOTAL IMPERVIOUS37,790 SFPERCENT IMPERVIOUS80.2%PERMEABILITY19.8%TP1SITE SOILS DATATEST PITSTP-1PERCOLATION TESTSIT-1 Gas ValveGas Test ValveGas Test ValveAsphalt ParkingAsphalt ParkingWood DeckSiloConcrete Pad with OverhangSignConcrete SidewalkSS-MHConcrete8'X4'Ø DRYWELLStopSign30MPHSignSSSign"Center Lane Only"CBDrainage GrateNG9-1NG9-2U.P.U.P.U.P.43.0'45.6'48.0'42.2'150.37'N 76°37'20" W50.50'N 37°13'10" W145.91'N 05°57'00" E S 80°34'00" E184.05'S 05°58'00" W 191.00'PARCEL 302.5-1-50Area=33353.0± SF0.77± AcresCedar Row Cedar RowA/C14" Maple20" MapleN 05°57'00" E75.00' 75.00' S 05°58'00" W S 80°34'00" E184.07'Adjoining House8.1'PARCEL 302.5-1-49Area=13779.1± SF0.32± AcresRim=97.76'FF=98.59'Elev.=98.51'FF=98.66'Rim=96.41'BM at HydrantBolt at ArrowElev.=104.91'Rim=100.05'100100100100 959595 95 9595 959595959595 PROP. ASPHALTPAVEMENT32-SPACES16-NEW SPACES11-NEW SPACES11-EXISTING SPACES8-EXISTING SPACES8-EXISTING SPACES 11-EXISTING SPACES11-NEW SPACES7-EXISTING SPACES7-EXISTING SPACES9-EXISTING SPACES9-EXISTING SPACES14-EXISTING SPA C E S 14-EXISTING SP A C E S 3-EXISTING SPACES3-EXISTING SPACES3-EXISTING SPACES3-EXISTING SPACES 4-NEW SPAC E S PROP. ASPHALTPAVEMENT32-SPACES+101+97+99+102+103+101+102+100+101+99+100+98+99+98100101 102 10399 98 9 7 10410175' FRONT SETBACK75' FRONT SETBACK75' FRONT SETBACK25' REAR SETBACK25' REAR SETBACK25' REAR SETBAC K 25' REAR SETBAC K 25' SIDE SETBACK25' SIDE SETBACK25' SIDE SETBACK25' SIDE SETBACK30' REAR SETBAC K30' REAR SETBAC K 30' FRONT SETBACKMDR ZONE(MODERATE DENSITY RESIDENTIAL)CI ZONE(COMMERCIAL INTENSIVE)MDR ZONE(MODERATE DENSI T Y R E S I D E N T I A L ) CI ZONE (COMMERCIAL INT E N S I V E )9.0'18.0'9.0'18.0'CB-1107.0'GRAPHIC SCALESITE PLANLOCATION MAPSITE LOCATIONNEIGHBORHOOD MAPSITE LOCATIONSITE DEVELOPMENT DATAPARCEL 302.5-1-49LOT AREA:0.32-ACRES /13,779 SFEXISTINGIMPERVIOUSAREASPROPOSEDADDITIONS TOIMPERVIOUS AREASPROPOSED TOTALIMPERVIOUS AREASMAIN BUILDING1,475 SF(1,475 SF)----ACCESSORY STRUCTURES440 SF(440 SF)----DECK, PORCH & PATIO645 SF(645 SF)----CONVENTIONAL ASPHALT/GRAVEL AREA3,535 SF2,876 SF6,411 SFPERMEABLE ASPHALT0 SF2,512 SF(50% REDUCTION OF 5,024)2,512 SF(50% REDUCTION OF 5,024)TOTAL IMPERVIOUS6,095 SF2,828 SF8,923 SFPERCENT IMPERVIOUS44.2%20.5%64.8%PERMEABILITY55.8%(20.5%)35.2%SITE DEVELOPMENT DATAPARCEL 302.5-1-50LOT AREA:0.77-ACRES /33,353 SFEXISTINGIMPERVIOUSAREASPROPOSEDADDITIONS TOIMPERVIOUS AREASPROPOSED TOTALIMPERVIOUS AREASMAIN BUILDING6210 SF----6210 SFDECK & PATIO240 SF----240 SFCONVENTIONAL ASPHALT/GRAVEL AREA25,245 SF(591 SF)24,654 SFPERMEABLE ASPHALT0 SF568 SF(50% REDUCTION OF 1,135)568 SF(50% REDUCTION OF 1,135)TOTAL IMPERVIOUS31,695 SF(23 SF)31,672 SFPERCENT IMPERVIOUS95.0%0 %95.0%PERMEABILITY5.0%0 %5.0%ZONING REGULATIONSMDR - MODERATE DENSITY RESIDENTIALTAX MAP NO. 302.5-1-49MINIMUM LOT SIZE = 1-ACREMINIMUM LOT ROAD FRONTAGE = 100'MINIMUM LOT WIDTH = 100'MAX BUILDING HEIGHT = 40'FRONT SETBACK = 30'SIDE SETBACKS = 25'REAR SETBACK: = 30'SHORELINE = 75'PERCENT PERMEABLE = 50%ZONING REGULATIONSCI - COMMERCIAL INTENSIVETAX MAP NO. 302.5-1-50MINIMUM LOT SIZE = 1-ACREMINIMUM LOT ROAD FRONTAGE = 50'MINIMUM LOT WIDTH = 150'MAXIMUM BUILDING HEIGHT = 40'FLOOR AREA RATIO = 0.3FRONT SETBACK = 75'SIDE SETBACK = 20' (50' TOTAL)REAR SETBACK = 25'PERCENT PERMEABLE = 30%MAP REFERENCES:OVERALL SITE PLANprepared for:Garden World Associates LLC537 Aviation Road - State Rt. 254 & 2 Carlton DriveTown of Queensbury, County of Warren, State of New YorkTAX MAP #'s 302.5-1-49 & 50Call Before You DigWait The Required TimeConfirm Utility ResponseRespect The MarksDig With Care800-962-7962www.digsafelynewyork.comDigSafely.New YorkHutchins Engineering PLLC291268-01-S3PROPOSED ZONE LINERELOCATE UTILITY POLEPROPOSED ARBORVITAE BUFFERPROPOSED ARBORVITAE BUFFERSITE SOILS DATATEST PITSTP-1PERCOLATION TESTSIT-1TP1SITE DEVELOPMENT DATACOMBINED PARCEL 302.5-1-50 & 302.5-1-49LOT AREA:1.09-ACRES /47,132 SFEXISTINGIMPERVIOUSAREASPROPOSEDADDITIONS TOIMPERVIOUS AREASPROPOSED TOTALIMPERVIOUS AREASMAIN BUILDING7,685 SF(1,475 SF)6,210 SFACCESSORY BUILDINGS440 SF(440 SF)0 SFDECK, PORCH & PATIO885 SF (645 SF)240 SFCONVENTIONAL ASPHALT/GRAVEL AREA28,780 SF2,285 SF31,065 SFPERMEABLE ASPHALT0 SF3,080 SF(50% REDUCTION OF 6,159)3,080 SF(50% REDUCTION OF 6,159)TOTAL IMPERVIOUS37,790 SF2,805 SF40,595 SFPERCENT IMPERVIOUS80.2%5.9%86.1%PERMEABILITY19.8%(5.9%)13.9%PROPOSED PERMEABLE PAVEMENTPROPOSED PERMEABLE PAVEMENTPARKING REQUIREMENTSCOUNTRY STOREFOOD SERVICE:TOWN OF QUEENSBURY REQUIREMENT:1 SPACES PER 4 SEATS100 SEATSSPACES REQUIRED: 25RETAIL BUSINESS:TOWN OF QUEENSBURY REQUIREMENT:5 SPACES PER 1000 SF OF RETAIL AREARETAIL SPACE: 5000 SFSPACES REQUIRED: 25TOTAL SPACES REQUIRED: 50ADA ACCESSIBLE DESIGN STANDARDS:NO. OF SPACES: NO. OF ACCESS. SPACES:1-25126-50251-75376-1004101-1255TOTAL EXISTING ACCESSIBLE SPACES:4TOTAL SPACES EXISTING PROVIDED:55NEW SPACES PROPOSED: 29TOTAL SPACES PROPOSED:84PROP. 20' x 41' x 4'DSUBSURFACE INFILTRATIONBED W/(3) ROWS OF(5) CULTEC XL330 CHAMBERSPROP. ASPHALT PAVEMENTWING SWALECATCH BASIN SCHEDULETAGLOCATIONSIZEGRATE EL.OUTLETCB-1SE CORNER OFPARKING4' x 4' I.D.96.310'' HDPE - INV. 93.1TO SUBSURFACE CHAMBERS10'' HDPE - INV. 93.1FROM EXISTING DWSITE SETBACKSCOMBINED PARCEL 302.5-1-49 & 50REQUIRED FORCI ZONEEXISTINGPROPOSEDFRONT(QUAKER ROAD)75'45.6'45.6'FRONT(CARLTON DRIVE)75'28.1'48.0'REAR (NORTH)25'8.2'107.0'REAR (EAST)25'43.0'43.0'PROP. MULCHED PERENNIALPLANTING AREA (428 SF)AREA VARIANCE SUMMARY§179-3-040 (B) (3) (b) [12] - PERMEABILITY- 30% MAX REQUIRED, 5 % EXISTING (SILO PARCEL),5.0 % PROPOSED (SILO PARCEL)- 30% MAX REQUIRED, 55.8 % EXISTING (RESIDENTIAL PARCEL), 35.2 % PROPOSED (RESIDENTIAL PARCEL)- 30% MAX REQUIRED, 19.8 % EXISTING (COMBINED PARCEL), 13.9 % PROPOSED (COMBINED PARCEL)- 16.1 % OF RELIEF REQUESTED MIN.³£DETAILSprepared for:Garden World Associates LLC537 Aviation Road - State Rt. 254 & 2 Carlton DriveTown of Queensbury, County of Warren, State of New YorkTAX MAP #'s 302.5-1-49 & 50Call Before You DigWait The Required TimeConfirm Utility ResponseRespect The MarksDig With Care800-962-7962www.digsafelynewyork.comDigSafely.New YorkHutchins Engineering PLLC291268-01-S4STANDARD SPECIFICATIONS FORINLET PROTECTIONASPHALT PAVEMENT DETAILCATCH BASIN DETAILSTANDARD SPECIFICATIONS FOR SILT FENCEDEFINITIONPURPOSEAPPLICATIONDESIGN CRITERIAFABRIC MATERIAL CRITERIACONSTRUCTION SPECIFICATIONSSLOPE LENGTH/FENCE LENGTH (FT.)SLOPESTANDARDREINFORCEDSUPER<2%300/1500N/AN/A2-10%125/1000250/2000300/250010-20%100/750150/1000200/100020-33%60/50080/750100/100033-50%40/25070/350100/500>50%20/12530/17550/250ASPHALT PAVEMENT WING SWALE DETAILSUBSURFACE INFILTRATION BED DETAILSEDIMENT CONTROL FENCE DETAILWINTER STABILIZATION STANDARDSSTABILIZATION··MAINTENANCE····SOIL RESTORATION NARRATIVE····EROSION & SEDIMENT CONTROL NOTES············EROSION CONTROL IMPLEMENTATION SCHEDULEPRACTICEIMPLEMENTATION TIMEDURATION OF PRACTICESEDIMENT CONTROL FENCEPRIOR TO CLEARING AND SOILDISTURBANCEENTIRE PROJECT (REMOVE AFTER FINALSITE STABILIZATION AND VEGETATIONESTABLISHMENT)TEMPORARY SEEDING & MULCHINGAFTER INITIAL SITE GRADINGUNTIL FINAL GRADING AND VEGETATIONESTABLISHMENTSTORMWATER DETENTION AREASDURING FINAL SITE GRADINGPERMANENTSEEDING & OTHER VEGETATIONSTABILIZATIONAFTER FINAL SITE GRADINGPERMANENTSHRUB PLANTING DETAILPERMEABLE ASPHALT PAVEMENT DETAIL