Loading...
2000-335 TOWN OF OUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building&Codes (518)761.8256 CERMTHFICATE OCCUPANCY Permit Number: Date Issued: Wednesday,December 26,2001 This is'to.certify that work requested to be done as shown by Permit Number has been completed. Tax Map Number: 523400-290-062-0001-012.000.0000 Location: 28 OVERLOOK Dr Owner: FAMILY GOLF CENTERS INC Applicant: FAMILY GOLF CENTERS INC This structure may be occupied as a: By Order of Town Board Townhouse TOWN OF QUEENSBURY Garage-2 Cars Attached Fireplace Director of Building&Code En rcement TONS OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building& Codes -(518)761-8256 BUILDING PERMIT Permit Number: 2000335 Application Number: 2000335 Tax Map No: 523400-290-062-0001-012-000-0000 Permission is hereby granted to: MICHAELS GROUP For property located at: 28 OVERLOOK Dr in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the.NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value . Owner Address: FAMILY GOLF CENTERS INC Townhouse 220,000.00 4TH FLOOR, 538 BROADHOLLOW Garage-2 Cars Attached MELVILLE,NY 11747 Fireplace Total Value 220,000.00 Contractor or Builder's Name j Address Electrical Inspection Agency MICHAELS GROUP NEW YORK BOARD OF FIRE UNDEI SUITE 1 10 BLACKSMITH Dr MALTA.NY 12020 Plans &Specifications 2000-335 LOT 12 HSE#28 OVERLOOK DRIVE 2600 SQ FT TOWNHOUSE WITH 2-CAR ATTACHED GARAGE AS PER PLOT PLAN SPECIFICATIONS $0.00 . PERMIT FEE PAID - THIS PERMIT EXPIRES: (if a longer period is required,anapplication for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the nQjuee b ztyl- June 12,2000 SIGNED BY for the Town of ueensb Q �y. Director of Building&Code Enforcement Building Permit Application Town of Queensbury - Dept. of Community Development, 742 [any Rotrd, QI(eensbary, NY I2804 176/-32561 NUTICE BUILDING & . CODE ENFORCEMENT Requirements prior to issuance A rscrmit must be obtnined before of this permit: PERMIT f IG 7 beginning construction. No inspections will be made until applicant has received Zoning B PERMIT IEE PAID' a VALID ]BUILDING PERMIT. All Area /Use RECRL tTlON FEE PAID $ applicants' spaces on this application MAY ?M5 MUST be completed abd•the signature PlaWting Boar AC�� Y REVIEWED BY.- of the applicant•must appear tar the SPR �yy OD I $UbdiLSatC,}i[tr �COD Btti Glins treslvrrar piication form. rr�x�,.. Recreation F �nr�l't� Applicant: �14� i�\1t�12C�S �tie'C,�yuCt� Owner: Address:14�1zC Address: Phone # (t",J_tz_) � 0� - l` � Phone # -- ( -----) ----- ------- Property Loca'(ton J. Ci�,f-��2 lonl� �7LQt��� ��t� ���� 1 � • Subdivision Namc. �UGZF'1c �pJ, l R\2s r') . rtil�[7�[�t L. Tax Map Number _ Section Titr,ck T rx NATURE OF PROPOSED WORK:New Building: TRUCTION:ES D MARKET VALUE OF THE residence / cot e Addition to Ruildin re nce / o ial OCCUPANCY INFORMATION: Alte on o ig: Primary Building - es a ommercial _X Single Family Dwelling- Si nc mmercIal Two Family Dwelling no c ng a exterior size Fami le > t�g� OfficeE' Othe Work (describe below) Mercantile Manufactur ( 1 7 2000. Other GROSS AREA OF PROPOSED STRUCTURE: TOWN OF QUEENtIaBURY 1st Floor. . . . . . . sq. f �'�� If ADDITION, N 2nd .Fleor. . . . . . . ._ jy� sq. ft� ?° of new addition be? : Other Floors . . . . . sq. f t-: Ala` (not unfinishedce llar or basement) ,ACCESSORY BUILDINGS : Detached Garage it 2 car TOTAL FLOOR AREA: a�� SQ. FT. _ C Attached Garage 1 , ��ca Private Storage Buil�ng SIZE OF NEW STRUCTURE : Commercial Storage Building 5Z FEET X 5-(9' FEET Other Foundation Type: Will any second-hand or ungraded Number of Stories : lumber be used?- If so, for what? (habitable space only) Tye, Height (grade to ridge) : c> feet TYPE OF HEATING SYSTEM: Number of fireplaces and/or woe stove (circle all which a plies ) to be installed: Electric / Oil j as / Wood. Forced Hot Air / Baseboard / Other Person responsible for supervision 'of work as regards to building codes i s : t ZL 2+Cr�Cxc-� CAR B �2K �,avtiz N _1 e A d r e s Phone l ;Builder: p Plumber: 2 Q ;Mason t:_ �.' �' ? Elecrica.an: — 2Z .DEGZARfITlON- Please sigtf belotiv after you have Carefully read the statenrent. To the best of my knowledge the statements contained in this application, together with the plans and specifications subrriittdd, are a true and complete statement of all proposed work to be done on the described premises.arid that all provisions of the Building Code, the Zoning Ordinance and all other laws pertaining to the proposed work shall be complied with, whether specified or noted, and that such work is'authorized by the,owner. Further, it is understood that Ttwc shall submit prior to a Certifii`cate of Oecup or Certificate of Compliance being issued,an AS BUILT PLOT PLAN by a Iicen'sed stuveyor; ra n to sc le, showing actual location of project on premises. r Signatui•c:' wner, owner's a&bnt, architect, contractor) Application for Permit—Septic Disposal System Town qf Queeilsbuiy 742 Baj,Rourel Queensbury, NY 12804 (5I ) 761-8256 1. OWNER INFORMATION: f �}Oer d' S.................:........................ .............................. ............. r�� Office Use Location of installation: IS e�Y�i;\caoK i✓ �u Tax Map No. Fite P ermit - 14119CIS-I NS' Owner's Name:TkAg-: — t� MA' .._. .......... ... ...., ..................... ................._.. ................................ Address: kc, P, ��� _.. 7"Olrtti"'I OF QUEENSB111jy 2. INSTALLER'S NAME ` �� 13UILDING AND O � 3. RESIDENCE INFORMATION: (circle year of dwelling, indicate #bedroorrr(s) and multiply# of bedrooms with applicable gallons per bedroom to equal total daily flow) Year of House: No of Bedrooms x Computation = Total Daily Flow 1980 or older x 150 gal/bdrm = 1980- 1991 x 130 gal/bdrm = 1991 -present 3 x l 10 gal/bdrm Garbage Grinder Installed yes _ / no Spa or Whirlpool Installed yes_ / no 4. PARCEL INFORMATION: (circle applicable information & indicate measurements) T ostrapli Soil Nature Ground Water Bedrock or Impervious Material Domestic Water Supper o Rolling satrd at what depth at what depth nnuiicipa� . Itollitrg loam _ Q feet —ftet t---"' Sleep slope clay i1*well; �t ester-.rrtpp/n %'slope other fi•onr tuft'.+'ehtic-sjslcnr depth: absorptinrr is other Percolation Test: (7b be completed by licensed professional engineer or architect) - --- __- Rate: _ minute Pei,inch 5: PROPOSED SYSTEM: For New Construction: All individual sewage disposal systems roust be designed by a licensed professional engineer or architect(unless installed in a Planning Board approved subdivision). Add 250 gallons to the size of the septic lank and leach field for each Garbage Grinder, Spa or Whirlpool Tub, Septic Tank: ItCCO gallon(inin. .size 1,000gal.) Tile Field: each trench ft. Total System Length: ft, Seepage Pit(s): number of �- size of•each: J1. by Size of Stone to be used: 11 � , � / depth or thickness _feet Bed System Size: z Alternative System: - -`--��-�--- length andlar size 6. HOLDING TANK SYSTEM: (if required) Number of tanks: 1�.�C,, J Size of each: gallons /TOTAL Capacity: gallons --- - Note: Alamz-System n�i Assoc ated'ele ircal"woFk riust"6ei ispected by a Town approved electrical inspection agency. 7. SIGNATURE &INFORMATION FOR RESPONSIBLE PERSON (please read) For your protection, please note that pursuant to Section 136-29 of the Code of the Town of Queensbury, any permit or approval granted which is based upon or is granted in reliance upon any material misrepresentation or failure to make a material fact or circumstance known by or on behalf ofan applicant, shall be void. I have read the regulations with respect to this application and agree to abide by these and all requirements of the Town\of Queensbury Sanitary Sewage Disposal Ordinance. Signature of responsible person Date TOWN OF QUEENSBURY Fee Paid BUILDING & CODES DEPARTMENT Permits APPLICATION FOR: PORCHES-DECKS= DOCKS & BOATHOUSES Est. Cost A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION. PLEASE ANSWER ALL OF THE FOLLOWING: The undersigned hereby applies for a Buildingl Pernir't-E �,p t�Q Mowing work which-.will be done in accordance with the description , plans and �specif� V�' bmitted, and such special conditions as may be indicated on the permit. TWO- SETS OF STRUC AL PLANS SHALL BE SUBMITTEI WIT11 THIS APPLICATION. IV114 T L ®Q� Owner of Property: "C.4-7 AAt6/L-fitF_ S V P ANOOODE P.O. Address /_ CS fjl AGK_shl�l�"1 1%> _tV, 1> Phone Il Property Location =J5r11 1tL ��1 G Tax Map' T— Subdivision Name (If applicable) _ PERSON RESPONSIBLE FOR SUPERVISION OF WORK AS REGARDS TO BUILDING CODES: TT-� Name: Pjj Address ._..__ Phone/l BUILDING SPECIFICATIONS: Type of work to be done : Porch Deck Dock Boathouse (Circle one) Size of Structure to be built (square footage) : Foundation Material : Width_ Thickness _ Depth of Footing, below grade: Size of Posts or Studs : x x Long Size of Floor Joists: x x Span_ Decking or Flooring Material : How will Porch or Deck be. fastened to building? If Roof Will Be Installed, Answer Following Questions: Size of Posts or Studs : _ x x Long Roof Rafters: x Spacing Span Roof Trusses (pre-engineered spacing) : Span Type of Roof: Sloped Flat Shed Other (Circle one) Material of Roof: ZONING INFORMATION: T140 •PLOT PLANS MUST BE PREPARED AND SUBMITTED, drawn reasonably to scale and attached hereto, showing clearly and distinctly all buildings , whether existing or proposed and indicate all set back dimensions from--property lines.' Show location of water 5ui)I)Iy and location and configuration of septic disposal area. Size of Property: ft. x ft. Existing building(s) : Size ft. x ft. Size ft. x ft. Use of Existing building(s) : Pro osed_ structure>,_d-i_s_tan�e:rro;.t proi)erty - p --- - '_ -Front r�ne ._=.. yard -- -ft. Rear yard ft. Side yards ft. and ft. If on corner, setback from S*T-d,-67 street: -ft. DECLARATION _ To the best of my knowledge and belief the statements contained.. in this application , together with the plans and specifications submitted, are a true and- complete statement of all proposed work to be done on the described premises and that all provisions of the .Building Code , the Zoning Ordinance, an'd all other laws pertaining to* the proposed work sha11 be complied with, whether specified or not, and tha - uc,h work is authorized by the owner. DATE: �' (C�w SIGNATURE Owner, Owner s -Agency, Arc-hi test, Contractor ItEVIE14ED 'BY CODE ENFORCEMENT OFFICER, DATE SIGNATORE - hit s ill lx'sltttt's Office, Town of Qucenst)111 742 Bay Ro.l(,Qut clisl)ttry, A l (SI$) 701-3205-` Application for Fuel Burning Appliances & Chimneys. applicable to solid fuel & vented gas appliances Date , 20 Permit ,application is hereb),made to the 1 13uilding c� Clxles p ic•e rr the issuance of a 13uilrling anal use lV Pet in itIMISMC.111t to the Nei I, York State 1--ire Prevention and 131111ding Code. Elie eil)l)liccii7t Or'CJis,,iiei- ' 1-ees to Comply ivtth al'l al)1)licable laws; orelinances', t .rgnlatioll:s, CHu1 all conditions that are part of these requir elnents and also will allow qll enterprenlises to perform required insl)celiolls. NOTE to applicant: Rough-in and Final Inspections are required. Applicant Information Fuel Bul-11ing Appliance Information. (circle app-bpriate %words) Name: 1X>-kckN tA$ Stove: wood coal pellet gas Fireplace insert Address: &" Fireplace, factory-built: wood c s # , Illuzo Fireplace, masonry: i,, wood gtrs Furnace: "'; wood . s3, oil Phone: ` If non-Illasonary applicance, please provide Owner: Mallti*f,kf,1rer Name: ----- _.,_Address: Model Ntuilt r:_ = Chimney Information Phone: (circle appropriate st;ords) Masonry. block , ,brick- stone Flue -tile kt 1 size: inches Exact Address: t� Ca'l_fig -lam K T_wf afcorlsnuctiort or installation Factory-Built Manufacturer name: rriF Model Number: tVote: Listed By: Number: umber: COnstruction 1111stallatlon 11111st toll farin to ATS Fire Prevention &Bu lding -,'Indicate (circle) chimney material: Code. Consult available Town of Queensbul), Handouts regarding required inspections. Double«-all ' Triple iYidl % Insulated / Direct Ve-1111,11cr I r�t,i �fxa€t'x�p, r. :71 �rtgt r lix�t, x tit-- 'mr rru es#' +Q►xx'ga4E3 x",;bxvx--y-, - TieVsr Yrax-1r I Fire rYlarshal Code# 3 Collcctcd S Re Jiwded llt'ttit cr./ir nimrr Jinlded It)): adth-ess: A 173 3389 (190) Public Safety• � _ __�7 42332655 (230)Minor Sales � While(Applicant) Green(Fire i.larshal) { - ,Yello%v.(B1dg.Deljt,) I Pink&Goldenrod(Cashier's Dept.) Pow -r(Z>VVf*4 OF ClUaF-=P4SE3UF2Y (=lUaaNlSaUF;,*-Y', M"Nr 1.2804 (518) 761-8205 FIRE MARSHAL INSPECTION REPORT REQUEST RECEIVED PERMIT NAME L(DOATI(DN SCHEDULE INSPECTION C)N /;kM FS" ANYTIME APPROVED N/A YES NO EXITS AISLE WIDTHS EXIT SIC3NS EMERC3ENCY LfGHT G33 FIRE EXTINGUISHERS FIRE ALARM SYSTE!M FIRE SPRINKLER S`x STE FIRE SUPPRESSIOM M HOOD INS-F.41-LATIC3N INTERfC:)R FINISHES STORAC3E: CLEARANCE TO SPRIN LERS CLEARANCE TO HEATIN UNITS REQUIRE© SIC3NAC3E CHIMNEY WOOD STOVE FIREPLACE - MASONRY FIREPLACE - FACTORY BUILT REMARKS: Q 8K TC:)'THIS DATE INSPEOTOR RESIDENTIAL FINAL INSPECTION REPORT Office No.(518)761-8256 Date inspection request received: Building&Code Enforcement Dept.of Community Development Arrive am/pm Depart` am/p, m Town of Queensbury Inspector, Initials 742 Bay Road Queensbury,New York 12804 NAME �� �A Gctrwn PERMIT 3 .4 LOCATION 1C DATE TYPE OF STRUCTUn N/A YES NO COMMENTS Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake Plumb Vent through roof Roof Complete Exterior Finish Complete hiterior/Exterior Railings 30"f to 36" Exterior Handrails,balconies,landing 18 A or more Interior Handrails stairs both sides 3 or mar risers Grade 2%away from faundatio� 8"clearance to sill plate . Gas Valve shut-off exposed/regu±r 18"a ove grade Gas Furnace shut-off within 30 feet or with n line of site. Oil Furnace shut-off at entrance to finac area Furnace/Hot Water Heater operating \, Relief Valve(s)installed Headroom,6 ft.G in.on stair' Basement stairs,6 ft.4 in. Handrail exterior stairs both sides more 3 risers Interior.privacy/hirn/doorslmain entrance G" Floor Finish BathroomMtchen watertight Interior Handrails Balconies/Landing 18 in. more Railing across window in stairwells _ Smoke Detectors: every level every bedroom outside every bedroom inter connected Bathroom fans Plumbing fixtures Foundation insulation s/4 hour fire door/door closer , Garage fireproofing r` Garage penetrations sealed / Furnace in separate room protected(in garage) Light ventilation per room . Safety glazing 18"or 1 ss tloo�r Final Electrical A 1A f00 Site Plan/Variance req Final Survey Plot Plan As Built Septic System layou required Okay to issue C/C(Certif.of Compliance) Okay to issue temp.C/O(Certif.of Occupancy) Okay to issue permanent C/O(Certif.of Occupancy) 0 � xxxro � c� 1n HNro � xr� � roan H�sHarz H a Hr � � Hr� HHHzor ,c� � �corx zo �c > o H z z z H H H P Pr o H c O r y H o c H 00 ro H n H � AOL H a a a H H H n r M t n M z o ff H M x H H o r r H H H I H N P d P n H p H W z rH F; n n n 0 N a a z a a % H N z H z H >z Q W H H > > H o of 0 m o o H 0 o 0 z ►c Hero o z .. N a r ro ro 1 H 0 0 X o H H Ui z z rn v, � z � roro � roro o o ro t�7 C a d a x H VJ z r Q N ►� > �) m n m N z > H n ro H n v > < r n H z N F H H C W n a o , H 00 0 � N t� > H � o or p z0H r0 ax I nc z ozrxxr� or m0 rw r m HH x x ro H H H C r x r nr � z ro v7 H n z 0z x w m I z x0 H H H I ' ro I z • z C N� o H >Ujo ,. 0 Oxz + 0 H w �S z Nao co a �p 16 LANDS OF N 9„ FAMILY GOLF -- _ 2g3.691 ��-..... ...._ N 0 '22 6'40" W 376.86' _ _— �56$ N lg•3 �y `� urs 1 29, 8 ��_............. R-243.00' 15 32 117.37' S 07y1'27- W N o6 33'07" W L-144.77' � J Q MAP REFERENCE: MAP OF A PROPOSED MODIFICATION OF OVERLOOK AT HIGHLAND PARK DATED: NOVEMBER 18, 1999 BY: VAN DUSEN & STEVES LAND SURVEYORS, LLC L=174.5 CIA J 3 ' j :• V 2 5 OR7 � LA 16 WOOD fRAME I S o 0 X �0. 613.41 , \ 08 52'S " 0999, ROO�ELL ROAD 425.41' R. ?ps p p: • S 06.55126, W AS 0 • PEE OF NE;k DuS P C V ICJ Land S urti ►� e y o r s , L 37 Chester Street dens Falls New Yor (518) 792-8474 C 12801 'UNAUROM ALTERAIM OR ADDITTDN TD A SURVEY NAP BEARNO A UCENSED LAND SIAWYORS SEAL DI A ATIO SUB-pNSNTN Z, OF THE NEW YDRI( STALE EDUCATION LAW.' NEW Y OF SW EDUCATION RM IM'ONLY WITH A FROM 7K OIOT E 10!' IkR ORS MAISitD WITH AN ORKTMI Of 11K WO StANLYORS 9EAL SMALL BE CONSIDERED TO BE YAIb TRUE COPIES,' `��A� �'"�° �°N CE 07H THIS xRTVEv RN9 PREPARED IN ACCORDANCE TMTH 1HE BY THE CODE OF PRACIWE FOR LAND OF PW RS ADOPTED BY 111E NEW YORK STALE ASSDCL1110N Qi PROFESSIONAL LAND STRNEYORS SAID CTATMTIONS SHALL RUN ONLY ON >� BEHALF 0 MTIT THE IS PREPARED. AND ON HIS BErwr ro THE ttTtE coWANY, DDVEwaErlra O b OF ,HE L MbTT ' "" New York Lic. No., 60135 Map of a Survey made for r I I IScate 1'=501v, THE MIE"HAELS GROUP S-1 2 11-13-00 A5-BUILT UNIT 15/16 840 1 OF 1 Town Of Queensb"�'' 'Warren County, New York 1 6-9-00 RI=VISE BUILDING LOCATION MGFtAElS GROUP COVERLOOIU NO. I DATE DESCRIPTION DWG. NO. OL-1516 Mahoney P.O.BOX 767 GLENS FALLS,I NEW YORK 12801 Notify-Plus Inc. 5181793-7788 FAX:518/793-0602 Decembe r 20, 200 Mr. Eric Wilson The Michaels Group 10 Blacksmith Drive, Suite I Malta, NY 12020 Re: 28 Overlook Drive Queensbury, NY I - Dear Mr. Wilson: This lette will certify that Mahoney Notify-Plus Inc., has completed the inspection and testing of the fire alarm devices as installed at the above address. At the time of the inspection all devices were found to be operating correctly. Should you have any question, please do not hesitate to contact our office. Sincerely, Edward J. Bol er Installation Foreman MINOWM�I- IMMA < DIDDLE DEPARTMENT INSPECTION AGENCY, INC. VpewAltta that the electrical wiring to the electrical equipment listed below has been examined and is approved as being in accord with the National Electrical Code, applicable governmental, utility and Agency rules in effect on the date noted below and is issued subject to the following conditions. . Owner: Farrone Date: November 16, 2001 Occupant: Same Location: Lot #38 Fair Lane Queensbury, NY Occupancy: Residence pp A licant. . Immanuel. Electric �M. 2 Mohawk Avenue --`' Alplause, NY ,-,1.2008' A No. Equipment: ; 33-Switches 52--Reeeptra'cl:e's. 31-Fi>xtures' 200Amp. Service Equipment ;4/,0' j " i 6-Smoke Detectors 3-V.ent'.-.Tans This certificate applies to the electrical wiring to the electrical equipment listed immediately null and void. This certificate applies only to the use,occupancy and .' above and the installation inspected as of the above noted date based on a visual ownership as indicated herein. Upon a change in the use,occupancy or ownership inspection, No warranty is expressed or implied as to the mechanical safety,effi• of the property indicated above,this certificate shall be immediately null,and void. . ciency or fitness of the.equipment for any particular purpose. This certificate shall In the event that this certificate becomes invalid based upon the above conditions, be valid for a period of one year from the above noted date. Should the electrical this certificate may be revalidated upon reinspection by Middle Department., system to which this certificate applies be altered in any way,including but not limit Inspection Agency, Inc. An application for inspection must be submitted to Middle ed to;the introduction of additional electrical equipment and/or the replacement of Department Inspection Agency, Inc. to initiate the inspection and revalidation • any,of the components installed as of the above noted date,this certificate shah be process. A fee will be charged for this service. i. t ,1 �•+ `f , �o m 0 Oro w Nfrnn our ct 4-J,(D a 0 w W, y ace a� n;3ti c c no rn PTO N MN 'U � � I -hv) N � n � (A 1 ".,�, 0 Poll 4.a �.d.I , +arm > �'�, � 0) � I < m s N .J. J.a, U1 0 0 � ~h 0 H -� � N I 0 0 0 '°a X d N '�Ut -jo r Nz (D 0) .1 q ;6 010111 0 , m w C � 0 � � Zo � i� oil (D '-,k 0 m c+F 0 i t , `h '-'� 0r 0 m �` �oTWO ° a � tow 41 'm Ono 1 rt n n m m m -J. m oC+ C+ c i Q 3 '`443r0 V' r 144r77 ' ' 1 r r r ,' ``�•. R-293,00 ff !,, J fir,+ �r , ,, J'A __ -�.•.- . MOPOSED BUILDING 76. 1 56, Roc avJ,S all OrVed jP��� or��� of, or l,�,cct�) Jig d 11 q�s plj�j e If�J�aSUr IJJJJ�,of i'.�vPils, IJ-F Sew evld ed NJe.r�is�l��° � � ��' fJJe , JI�� s of afJc s scl o�JI tlJa�l ittc., , JIIJ JvH lNgj�� 01J 11je L a�1�ntr0 t�0V10�10�10C°-0C� O z ro of ' a � we NmNro � y0-:3 1 H:� roOUror+w ' m zro I10o � " �� r� t 11 '� r c ct to 0o o 0 #+ N m' 4 m� to o r 00300 :3 :3 :500 J. —I tD aarDon(a mrort (A0 �01 (D C40 � .r (+ � o 0010 o 0z 11 •17 -0WO -ho 0 >-j - MR--im �q r q� C1'a • �(D o -h { rh © 0 `S \ ma 700. T-J Q 0 m N " cD � m q ro , i 0 (D � 0 «� � N ' } M n (A 000 C+ Are A, 2(D (D (D fD o rtnc (+ a 1 G_ENERA L INSPECTION REPORT (518) 761-8256 Town of Queensbury Dept.of Community Development Date inspection request received: Building&Code Enforcement 742 Bay-Road Arrive in Depart 0 Queensbury,NY 12804. in�S Inspector's Initi # 0 OC C�j nXAtO t, NAME: PERMIT LOCATION: S 0 Pit.- DATE.. TYPE OF STRUCTURE: �fV(q qQ 1,::2 g2 RECHECK N/A YES NO COMMENTS Footings/Piers Monolithic Pour Form Reinforcement in Place The contractor is responsible for providing protection from freezing 48 hours following the plat emenRt ,,� of the concrete. Materials for this purpose on sit Foundation/Wallpour_ Reinforcement in PlaceL Foundation/Danipproofing Backfill Approval Plumbing Under Slab Plumbing Vent/Vents in Place Rough Plumbing Heating Rough In Insulation Foundation Walls Interior R­ Foundation Walls Exterior R- Floors R- Walls R- Ceiling R- sa work or piping in unheated spaces R- nProy Vent� gj!e_L a Jack Studs/Headers Bracing/Bridging Joist Hangers Jack Posts/Main Beam Air hifiltration Barrier Fire Separation 1,2,3, hour Penetration Sealed Fire Wall 2,3,4 hour Firestopping C cO E GENERAL REPORT ( 518) 761-8256 Town of Queensbury Dept.of Community Development Date inspection request received: Building&Code Enforcement 742 Bay Road Queensbury,NY 12844, Arrive Depart m cctor's llniti r NAME: (.c� t� PERMIT# 00 - 3 3 S LOCATION: !S Qye-&I oo k DATE: QC) TYPE OF STRUCTURE: RECHECK. N/A YES NO COMMENTS Footings/Piers 1 Monolithic Pour Form Reinforcement in Place _ The contractor is responsible for ' providing protection from freezing f for 48 hours following the placement of the concrete. Materials for this purpose on site Foundation/Wallpour Reinforcement in Place Foundation/Dampproofing Backfill Approval Plumbing Under Slab lumbing Vent/Vents in Place Rough Plumbing t Heating Rough-In Insulation Foundation Walls Interior R Foundation Walls Exterior R- Floors R- Walls R- Ceiling R- Duct work or piping in unheated spaces R- Proper Vent,Attic Vent i ` i Framing "- Jack Studs/Headers Bracing/Bridging Joist Hangers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1,2, 3,hour enetration Sealed A�Iire Wall 2,3,4 hour Yrestoppin FIRE +�n,A.RSHAL �I �- TC:)VVN OF QUEaNSSURY CaUEENSBURY, NY 12804 (518) 761-8205 FIRE MARSHAL INSPECTION REPORT REQUEST RECEIVED NAME .�� c-1 LOCATION/, "Z •'' UE vv, PERMIT #-;;; t6 o o - 33- SCHEDULE INSPECTION ON ` Z APPROVED N/A YES NO EXITS AISLE WIDTHS EXIT SIGNS EMERGENCY LIGHTING FIRE EXTINGUISHERS FIRE. ALARM SYSTEM FIRE SPRINKLER SYSTEM FIRE SUPPRESSION SYSTEM HOOD INSTALLATION INTERIOR FINISHES w STORAGE: CLEARANCE TO SPRINKLERS CLEARANCE TO HEATING UNITS REQUIRED SIGNAGE CHIMNEY IL A WOOD STOVE FIREPLF-AC4f 0 -MASONRY FACTORY B ROUGH-IN 0 FINAL REMARK, � [� OK TO THIS DATE ts INSPSLIP.PUB INSPEC7tR/ FIFE IVI^F:P,'SH^t_ TOWN (D F= <:'Zk U EE I-=r4 S E3 t_J F:;;,")r CkLJU_IEM,SE3IJF;Z'N4r, M-)r 128046 4E:kw (51 B) 745 1-820S FIRE MARSHAL INSPECTION REPORT REQUEST RECEIVED O-N NAME %k LOCATION SCHEDULE INSPECTION ON AM PM APPROVED N/A YES NO EXITS AISLE WIDTHS EXIT SIGNS EMERGENCY LIGHTING FIRE EXTINGUISHERS FIRE ALARM SYSTEM FIRE SPRINKLER SYSTEM FIRE SUPPRESSION SYSTEM HOOD INSTALLATION INTERIOR FINISHES STORAGE: CLEARANCE TO SPRINKLERS CLEARANCE TO HEATING UNITS REQUIRED SIC3NAC3E CHIMNEY OD STOVE --- 00 "--FIREPLACE F-1 MASONRY "FACTORY BLT. O ROUGH-IN FINAL aX. I I I REMARKS: E-1 OK TO THIS DATE INSPSLIP.PUB INSPECTOR Ckyv GENERAL L SFECTION REPORT ( 518) 761-8256 Town of Queensbury Dept.of Community Development Date inspection request received: Building&Code Enforcement / 742 Bay Road Queensbury,NY 12804. Arrive am/pm Depart Gl Inspector's Initials NAME: —y PERMIT# f LOCATION: Qy DATE: r TYPE OF STRUCTURE: RECHECK. N/A YES NO COMMENTS Footings/Piers / ``� I Monolithic Pour Form _ Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site Foundation/Wallpour Reinforcement in Place �E Foundation/Dampproofing Backflll Approval Plumbing Under Slab Plumbing VentlVents in Place Rough Plumbing Hea ough In lation �,gz Foundation Walls Interior R- Foundation Walls Exterior R- Floors R Walls R Ceiling R Duct work or piping in ` unheated spaces R- Proper Vent,Attic Vent Framing Jack Studs[Headers Bracing/Bridging Joist Hangers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1,2,3,hour Penetration Sealed Fire Wall 2,3,4 hour Firestoppmg F=IFZa MARSHAL TOWN OF (::lUP-ENSE3LJF;Ve' C;)LJaaN,c-3E3UF:Z'Y, NY 12804 (518) 761-8205. FIRE MARSHAL INSPECTION REPORT REQUEST RECEIVED NAME LOCATION PERMIT SCHEDULE INSPECTION ON AM PM APPROVED N/A YES NO EXITS AISLE WIDTHS EXIT SIGNS EMERGENCY LIGHTING FIRE EXTINGUISHERS FIRE ALARM SYSTEMS, FIRE SPRINKLER SYSTEM FIRE SUPPRESSION SYS-rkEM HOOD INSTALLATION INTERIOR FINISHES STORAGE: CLEARANCE TO SPRINKLERS CLEARANCE TO HEATING UNITS REQUIRED SIONAGE CHIMNEY WCInD STOVE --�IREPLACE F--1 MASONRY EPTFACTORY BLT- OUQH-IN FINAL REMARKS: OK TO THIS DATE INSPSLIP.PUB INSPECTOR r GENERAL INSPECTION REPORT (518) 761-8256 Town of Queensbury Dept.of Community Development;� Date inspection re uest received: Building&Code Enforcement/1 742 Bay Roads Queensbury,NY 12804. Arrive am/pm Depart Inspe tor's Initials NAME: ,�' PERW," T# LOCATION: DATE: TYPE OF STRUCTURE:,! RECHECK l� t aj i�4 � 1a' s N/A YES NO ;f' COMMENTS Footings/Piers —T I;s' Monolithic Pour Form Reinforcement in Place The contractor is responsible for providing protection fron%freezing s :for 48 hours following thelplacement of the concrete. ' Materials for this purpose on site Foundation/Wallpour ( Q ) Reinforcement in Place I .i I 4 LAN Foundation/Dampproofing X Jf _ Backfill Approval r-i r Plumbing Under Slab t umbing VentlVents in Place tl. alrlt �n�ngrJ,' eating ough-ln 117 Insulation rsf Foundation Walls Interior R Foundation Walls Exteriork,R- Floors R­ ' Walls i R- Ceiling R- Duct work or piping in unheated spaces'" R- Proper Ven Attic Vent Bracing/13odging '! C' l f �2J}1 sue.. c I l2�te Ta u5 5 Joist Hangers Xi'. Posts/Main B eam '. ���g 3C-a�fZj� jakp, J t IV Separatl'on 1,2,'hour ' netrati ealed "► C r 1 a 4*hour �.; 1 U6- 7 c3s rfA, �:F.ixestotranng. LU(-5 . GENERAL INSPECTION REPORT (518) 761-8256 Town of Queensbury Dept.of Community Development Date inspection request received: Building&Code Enforcement 742 Bay Road Queensbury,NY 12804. Arrive am/pm Depart_��a pm Inspector's InitialsG* l NAME: 11 0 1 e PERMIT 4 ©CATION: cm DATE `7 TYPE OF STRUCTURE: RECHECK N/A YES NO COMMENTS Footings/Piers \ Monolithic Pour Fo Reinforcement in PI ce The contractor is sponsibi for providing protec on from fre ping for 48 hours foll g the pl cement of the concrete. Materials f this rpose o ite Founda,o ur Reinforcement in lace Foun��#on/Dam roofing �„��rC2cfi11 Approval Plumbing Under lab Plumbing Ventltl nts in Place Rough Plumbing Heating Rough- Insulation Foundation W s Interior R- Foundation W s Exterior R- Floors R- Walls R- Ceiling R Duct work or piping in unheated spacJs R Proper Vent, Attic Vent Framing Jack Studs/Headers Bracing/Bridging Joist Hangers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1,2, 3,hour Penetration Sealed Fire Wall 2,3,4 hour Firestopping 3 - GENERAL INSPECTION REPORT ( 518 ) 761-8256 Town of Queensbury Dept.of Community Development Date inspection request received: J Building;t& Code Enforcement 742 Bay Road , Queenshury,NY12804 Arrive am/pm Depart � Inspector's In��it}}ials NAME: PERMIT# C7��- LOCATION: v-e- ISATE TYPE OF STRU TURE: t - RECHECK N/A YES O COMMENTS otings/Piers /I Monolithic Pour Form Reinforcement in Place "'� The contractor is responsi le fors 1 providing protection from reeztng for 48 hours fallowing the lacement of the concrete. Materials for this purpose on s tc Foundation/Wallpour Reinforcement in Place Foundation/Dampproofi ng_ Backfill Approval Plumbing Under Slab Plumbing Vent/Vents in Place Rough Plumbing Heating Rough-In Insulation Foundation Walls Interior R- Foundation Walls Exterior R- Floors R- Walls R- t Ceiling R- Duct work or piping in unheated spaces R- Proper Vent, Attic Vent Framing Jack Studs/Headers Bracing/Bridging Joist Hangers Jack Posts/Main Beam Air Infiltration Barrier_____ Fire Separation 1,2, 3, hour Penetration Scaled Fire Wall 2, 3,4 hour Firestopping F IlF,PIE M^f:;;"S"^L- -r(DWN C>F ClLJr-=F-=NSF3LJl:Z"Y QLJEHIENSE3LJIR.-Y, N-V- 12804 (518) 761 -8205 . FIRE MARSHAL INSPECTION REPORT REQUEST RECEIVED NAME S <�F=- LOCATION PERMIT # SCHEDULE INSPECTIO AM PM APPROVED N/A YES NO EXITS AISLE WIDTHS EXIT SIGNS EMERGENCY LIGHTING FIRE EXTINGUISHERS FIRE ALARM SYSTEM FIRE SPRINKLER SYSTEM FIRE SUPPRESSION SYSTEM HOOD INSTALLATION INTERIOR FINISHES STORAGE: CLEARANCE TO SPRINKLERS CLEARANCE TO HEATING UNITS REQUIRED SIGNAGE CHIMNEY WOOD STOVE \.., IREPLA 0MASONRY FACTORY BLT- ROIUQH-IN E:l FINAL REMARKS-.-ti-, ED OK TOTHIS DATE INSPSLIP.PUB INSPECTOR oe3 5J� <1 1 NEW YORK STATE DEPARTMENT OF STATE STATE FIRE PREVENTION AND BUILDING CODE COUNCIL Certificate of Acceptability No. 0009 George E.Pataki Governor Alexander F.Treadwell Expiration date : May 11, 2002 Page 1 of 4 Secretary of State L MANUFACTURER G-P Gypsum Corporation 2861 Miller Road Telephone:(770)987-5190 Decatur,Georgia 30035 Fax:(770)981-6356 2.PRODUCT G-P Gypsum Series 600(NY),Gyproc 2-Hour Area Separation Wall Solid Type. 3.USE Two hour party/fire wail in dwellings not exceeding two stories in height,classified group A 1,A2,B 1,B2,133,or 134 occupancy. 4.DESCRIPTION 4.1 General The G-P Gypsum Series 600(NY)Gyproc Area Separation Wall-Solid Type consists of 2"deep steel H-Studs which secure the vertical edges of abutting double I"thick by 2'-0"Gyproc Fireguard Shaftliner panels covered by 1/2"by 4'-0"Gyproc Fireguard C gypsum board on both sides to create a vertical non-load bearing noncombustible party/fire wall. The party/fire wall assembly is supported at the base by a steel C track fastened to the foundation and at the ceiling by aluminum clips attached to the building wood framing. If exposed to fire,the aluminum clips melt and break away permitting construction damaged by fire to collapse while the party/fire wall remains intact,thereby maintaining protection of adjacent construction. 4.2 System Components 4.2.1.C Track The C Track is a nominal 25 gage,2"wide web with I"deep flanges,hot dipped galvanized steel track. It is attached to the foundation with power driven or other appropriate anchors to laterally support the base of the wall assembly. 4.2.2 H-Stud The H Stud is a nominal 25 gage,2"wide web with 1-1/4"overall wide flanges,hot dipped galvanized steel stud.It secures the vertical edges of the abutting shaft liner panels between the foundation and ceiling and between.floors. 4.2.3 Gyproc Fireguard Shaftliner The Gyproc Fireguard Shaftliner is 1"thick by 24"wide and complies with ASTM C 442. Two abutting layers are inserted in the C Track with the H Stud fitted over the long edge to form the solid core of the wall assembly. 4.2.4 Gyproc Fireguard C gypsum board The Gyproc Fireguard C gypsum board is 1/2"thick x 48"wide and complies with ASTM C 36. A layer is required to cover each side of the abutting shaftliner panels to create a vertical non-load bearing noncombustible party/fire wall assembly. 4.2.5 Angle Clip Aluminum angle clips are 1 It x 2"to 2-1/2"x 2"wide x 0.050"thick(minimum). The clips attach each side of every other H-Stud to the adjacent wood framing. 4.2.6 Fasteners (a)1"Type S drywall screws;(b) 1-1/4"Type W drywall screws;(c)3/8"Type S pan head screws.Each aluminum angle clip is attached to an H-Stud.with a 3/8-inch Type S pan head screw or 1-inch Type S screw,and to the wood framing with a 1-1/4-inch Type W screw. 4.2.7 Fire stopping Gypsum board strips,or mineral fiber safing insulation(4 lbs per cubic'foot nominal density}. DOS-1331(10/97) ,ti `Certifi6te of Acceptability No. 0009 Expiration date;May 11,2002 Page 2 of 4 4.3 Installation 4.3.1 Fire Stopping Mineral fiber safing insulation(4 pcf minimum density)or gypsum board strips as shown in Detail No. I shall be used to fire stop openings adjacent to the party/fire wall at floor and ceiling levels,and at terminations with the roof deck or exterior walls in Details No.2. For one-and two-family dwelling,the party/fire wall shall extend at least 6"above roofs of combustible construction, and at least 6"beyond exterior walls of combustible construction. As an alternative;the party/fire wall may terminate at the underside of a roof and at the interior surface of an exterior wall where such roof and wall are protected construction having the same fire resistance rating as the party fire wall,for a distance of at least 18"at both sides,of the party/fire wall. For multiple dwellings,party/fire walls shall extend at least 24"above roofs and at least 12"beyond exterior walls.As an alternative,party/fire walls may terminate at the underside of a roof,and at the interior surface of an exterior wall where such roof and wail have a fire resistance rating of less than 3/4 hour,and are protected with noncombustible construction having the same fire resistance rating as the party/wall for a distance of at least 24"at both sides of the party/fire wall. Party fire/walls may terminate at the underside of a non-combustible roof, and at the interior surface of a noncombustible exterior wall where such roof and wall have a fire resistance rating of at least 3/4 hour. Party/fire wall projections through roof decks or exterior walls shall be covered by noncombustible flashing that will resist corrosion and galvanic action,and be designed to have a sliding and slip-type ability that will allow for expansion or fire collapse. 4.3.2 Openings and Penetrations in Fire Walls Openings are permitted in fire walls as described herein,. There shall be no openings permitted in the party wall. Openings are permitted for-doors not exceeding 44"x 88"and for large ducts,or groups of ducts not exceeding 5 square feet. Such openings shall be framed around the full perimeter of the opening with suitable steel studs and channels to maintain adequate support for the wall,and shall be protected by an opening protective having a fire-resistance rating of at least 1-1/2 hour installed in accordance with the terms of its listing by a recognized testing agency. Penetrations through the gypsum panels to permit passage ofnoncombustible pipes,small ducts,and electrical conduits shall be permitted in fire walls provided any such opening does not exceed 20 square-inches in any 100 square feet of the face of the fire wall,and that the size of any such penetration that would permit the passage of flames and hot gases be no more than 1/2"larger than the outside dimensions of the pipe,small ducts,and electrical conduits. Penetrations shall be tightly fire stopped using mineral fiber safing insulation or Fire Halt Sealant. 4.3.3 Field Erection Beginning at the concrete foundation,a horizontal 2"C Track is attached with power=driven fasteners or equivalent anchors spaced not over 24"o.c. Two layers of V Fireguard Shaftliner with the.H-Stud fitted over the long edges of /f the shaftliner are inserted into the C Track and installed progressively forthe full length ofthe party ire wall. All field erected shaftliner panels shall be tightly engage to the H sections and C Track. On each side,a layer of 1/2,"Fireguard' C gypsum board is screwed to the H-Studs and-C Track with I" type S screws-1211 o.c. Every-other H-Stud is connected to.the adjacent Wood ftaming at the ceiling level with aluminum angle clips,one on each side.Each clip is attached to an H-Stud with a 3/8"Type Span head screw or 1"Type S screw,and to the wood framing with a 1-1/4" Type W screw-(see Detail No.1). The height of the H Studs and shaft liner.panels between the foundation and ceiling level,and between the floors shall not exceed 10'-0". The top of each section of the assembly which shall extend 3"io,6"'above the floor or roof-ceiling. framing is capped with a C Track. UA Sound Transmission Where required by Code Section 732.2(c)(2),,the construction of the framing adjacent to the party/fire-wall shall be completed so as to provide the sound transmission loss between dwelling units. Sound transmission loss requirements are met with 1/2" gypsum board fastened conventionally with nails or screws to the 2x4 wood framing, and with insulation in the cavity on both sides of the Gyproc Area Separation Wall(Details-I and 2). DOS-1331(10/97) Certificate.of A ccep ta bility No. 0009 'Expiration date May 11,2002 Page 3 of 4 5.BASIS FOR ACCEPTABILITY 5.1 Applicable code sections 5.1.1 NYS UFPBC Section 606,.3(a)(84)defines fire wall as a wall of noncombustible construction,with qualities of fire' resistance and structural stability,which completely subdivides a building intb,fire areas and which resists fire spread. 5.1.2 Section 610.1(d)requires that assemblies of building construction to be tested in accordance with reference standard RS 4-1,ASTM Standard E119-88 for fire endurance rating. 5.1.3 The State Fire Prevention and Building Code Council has adopted as test procedures for"fire walls/party walls"the ASTM Standard E 119-88 Section 9 Fire Endurance Test and Section 10.3 Hose Stream Test Optional Program. 51 Submitted information 5.2.1 Drawings have been provided and,are on file representing vertical and horizontal cross sections of a typical wall with the system components noted in the details. 5.2.2 The manufacturer has provided a copy of the evaluation report for Test Number WHI-495-1294 on the wall assembly issued on April 3,1995 by Warnock Hersey which concludes the assembly successfully completed the code council test procedures for party/fire walls in accordance with ASTM Standard E-119 The product compliance satisfies the requirement of 9 NYCRR 610.1(d)for a hr fire resistance rating. 6.CONDITIONS OF ACCEPTABILITY 6.1 This certificate is valid for,a period of two years from date of issuance unless sooner revoked;and is subject to renewal thereafter.Certificates that are not re-certified shall not be used or referred to.In order to determine the current certification status,please contact the Division of Co'de Enforcement and Administration at(518)474-4073. 6.2 The manufacturer shall supply instructions that provide information on the approved installation and use of the product. Any conflicts between this certificate and the manuf4durer's installation instructions void this certificate.Materials and methods of construction shall conform to the test results,brochure, and specifications submitted to and on file with the Division. 6.3 The party/fire wall components shall conform to the drawing and specifications submitted to and on file with the Department of State Codes Division (see detail No.1 and No.2 6.4 A registered architect,licensed professio nal engineer,or,approved inspection agency shall certify to the building official that the party/fire wall assembly complies with the requirements set forth in the Certificate of Acceptability. 6.5 The party/fire wall and building shall conformwith the requirements of subdivision 4.3 above for fire stopping , openings in fire walls,field erection and sound transmission. 6.6 That the building shall be classified as a one and two-family dwelling,or as a multiple dwelling of Group B 1,B2,B3,or, B4 occupancy containing dwelling units or sleeping rooms. 6'7 The party/fire wall shall serve as a nonbearing,noncombustible wall. 6.8 In the event the party wall becomes exposed to the exterior,the authority having jurisdiction shall require the person having responsibility for the building to cover the exposed side of the wall with material that will provide adequate protection so that it can serve as an exterior wall. 7.INFORMATION TO BE SUBMITTED TO CODE ENFORCEMENT OFFICIAL. In order,to aid in-determination of compliance with this certificate,documents submitted to officials charged with enforcement. of the code shall reflect at a'minimum the following information: 7.1 Manufacturer Installation Instructions. 8.PRODUCT IDENTIFICATION 8.1 The system Components shall bear manufacture's name and model number. 9.REFERENCED INFORMATION 9.1 The separation wall was previously covered under Certificate of Acceptability 579-19 1-MC. This certificate was amended in 1995 to require full coverage of shaft panels with gypsum wall board in lieu of 6" battens, and to reflect changes in ownership on April,15,1996. 9.2 The following figures of Detail No.I and Detail No.2 are reprinted from manufacturers literature.The drawings shown below are for illustration purposes only.They are not intended for use as construction documents. DOS-1331(10/97) ,C_eitificate of Acceptability No. ,0009 Expiration date :May 11, 2002 Page 4 of 4 w NEW YORK STATE DEPARTMENT OF STATE UNIFORM FIRE PREVENTION AND BUILDING CODE CODES DIVISION CERTIFICATE OF ACCEPTABILITY (Amended 1995) (Revised 1998) DETAIL NO. I DETAIL NO. 2 ®TWO 1-GYPRCC ( 1-GYPROG ola-GYPRCC SHAFTUNER SHAFTUNE FIREGUAR `-,�Y PANELS GYPSUMS AD DOUBLE C TRACK ill"GYPSum '? SCREWED BACK INTERIOR BOARD TO BACK OOD ALUMINUM - s FRAMING \ ANGLE CUP : Q 2'G TAAC�( ' ' . (y}i•TYPESSCREW 2'HSTUD x"^^ 1 1/4-TYPE W SCREW FLOOR 1• PE SCR e a5: ,a si5 FIRE 8L UMNG, �• GYPSU BOARD OR ?=: MINE RA INSULATION nsaz`si'::• 5:z, z:;: a:a g; ..:.::...:.�; , u�cz' �`u"fawsc' iix�eiFt^iu«x�w�{:�a!xw^u„w$a,�rzv,3,.,rt;tin�v� __--JOIST U i . 5UM BOARD Q V2'GYPROG CAULK FIREGUARD C 2.H STtI " h`t GYPSUM BOARD SMOKE S°i`::i: TIGHT FIRE BLOCKING. GYPSUM BOARD OR MINERAL INSULATION 18'FOR 1 AND 2 FAMILY.MIN, 24"FOR MULTIPLE FAMILY INTERMEDIATE FLOOR INTERSECTION � EXTERIOR FACING EXTERIOR WALL " FRAMING EXTERIOR WALL INTERSECTION 1. "C Track"nominal 25 gage,2"wide web with 1"deep flanges,hot dipped galvanized steel. 2. "H-Stud"nominal 25 gage,2"wide web with 1-1/4"overall wide flanges,hot dipped galvanized steel. 3. Gyproc Fireguard Shaftliner, 1"thick x 24"wide(ASTM C442). 4. Gyproc Fireguard C gypsum board,4/2"thick by 48"-wide(ASTM C36). 5. Angle Clip- 1"x 2"to 2-1/2"x 2" wide x 0.050"thick(minimum). 6. Fasteners-(a) I"Type S drywall screws:(b) 1-1/4"Type W drywall screws;(c)3/8"Type S pan head screws. 7.Fire stopping,Gypsum board,or mineral fiber safing insulation(4 lbs.Per cubic foot nominal density). This Certificate of Acceptability certifies that the State Fire Prevention and Building Code Council has determined that the product specified in Division file No.CA 0009 complies with the performance requirements set forth in the New York State Uniform Fire Prevention and Building Code when installed in accordance with the Conditions of Acceptability listed under Section 6 above. Please contact the Division with any questions you may have regarding this certificate or if you have any information on the performance of the product described herein which is contrary to this certificate. or j� Date of issuance: May 11, 2000 �•'` George E.Clark,Jr. Director,Division of Code Enforcement and Administration DOS-133I (10/97) 24' OYP. LINER PANEL 2" LrSe G—RUNNER NEW PORK STATE ENERGY CONSERVATION CONSTRiJCTSON CODE ' PART S COMPL2ANC8 82)iLDING DESIGN BY AGCEPTA$LE PRAC['fCE rYP. ROOF TRUSS 2'—d' MIN. 33X7II.DIN4C3 E7C.:�/"LxL.OPE DATA DLOCKINC7 MINIMiJM SIDE`_ EI�iVA..Z.OPE CQMPCINL-N'T REq_iLTgt,ED PROVaPED RO&T EXTERIOR WALL R�3S R-16.01 ROOF/CE[L1N4 R^r.L4 R.-29.4 I'TL.00R Rif9 R.-90.9 FOUNDATION WALL R-10 R-14FIP�ERC�l.AS- INSUL. ROOF SLAB EDGE INSUL.AXlON P-10 N/A GHGR PANEL OLA21N0 R 3.7 R-3.9 TYP. ENTRANCE DOOR RY2.5 R�10 I/2"` F INSL.TLATED DEPTH$ELOW.GRAI7E D-�[8•' D-48'• SKYZSGHT R�2.7 R-S.S I/2"C' S1CYLfGHT%OF TOTAL ROOF AREA M.MAXIMUM <f AL" H-STL 2 P�4RTY Wt�LL C� RDOF 1/2:' FfREGCT E 'G' 61PStRt PANEL (/2" AIR SPADE W/�ERTIGFkL DFF� T 5u TJI FI..00R J015T IN, RETURN WHFN ORIZ. DIST. <4 OF U50 OYPSLM LINER PANELS ' WALL PLATES (T DEAD OF ACLU TIDAL SEAL4NT d a I/2" WAFERWOGP TOO M COW. ANNP !d` PGUREP t ONGRETE WALL 5HEA3FjIN6 @ EACH SIPE OF C—TRACK d r WALL HORIZONTAL ALUMINUM --- FILL W/1' STEEL- POKER SIPINO DRIVEN ANCHORS 24" OC. s CENTERLINE OF 2" LINER PANELS p PARTY WAIL & CENTERLINE Cr FNP. WAIL 5/4x3 FURRI14G 0 24"O.C. d a� RT. OVER METAL'H-STUDS • r G-GH a a' d IX E7YP. fV. 2 { d n ° LINER V, Lis FASTf EPCA-ASS OG• IN .(R—!1) d r2-x4 Y" n a IG'" Ot d n;.d a• 3 P,4RT1' W,�tL ® EXT Al W/HDRIZDNTLAL OFFSP4 ET` o I FARTY WALL (9 FDUNZ ATIDN ;HALL THE ALTERATION DIRECTION OF A VIOLATION OF TF ULATIONS AND (. ci E rn z_mom c 2'-G" MIN. ooaEv (K C p • t7�•-U 9!•-(� ' m0'oC�CZ J a U O 6 U 2 CHAP @ SlEATHINO I" F-5 ToFICER IE st-. AT TOP OR w VLC•- ¢a000�a I — SIDES rG PROVIDE SMGKE SroP. L)z�flW-R INS-L. AT TOP OR 2-I" GYP. LINER PANEL o e a` to PROVIDE SMOKE STOP ROOF SHEATHINC? v v o v 2" LYC7 C-RUNNER w> o c'm `ATHIN6 TYR ROOF 6LOGIVNC7 a E Tj m r E 0 U U N O O—p.cT� ROOF T DROP To FI6ERC�LAS CHORD V FOR 6YP. LINER 55 DROP TOP INSLIL, PANEL FOR C7YP. LINER TYP. US& 2 HR. FIRE 6ARRIER 2 HR. FIRE f5ARRIER I/V FIREcXE 'G` CaYPSUM PANELS XE G' C7YPSLM PAhIELS I/2"eYP. DR V. WALL CLIPS L CLIPS ATTACHED TO METAL /3/8" TYPE 'S' SCREWS ETAIL 4 PARTY WALL Cam? ROOF I?ETAIL WALL PLATES (TOP & DOrTOM) TO DE GGNr. ANP GUT rO FIT f=LOCKINCti MUST MAINTAIN— FILL w/I" R-MAX I" CLEARANCE FROM &L.P. OTTOM) I,_6„ ro FIT R-MAX �,O I/2" WAFERWox 62 {}a;3 STEEL Y > WALL SHEATHING G-CHANNEL1 �Q HORIZONTAL ALINIIN N I/2" FIREGGDE 'G' OYPSLM PA S SIDING TO GONER H--5TUD5 TYP. I/2" GYP. 6D. � 2—•• Syp EFJ_ LIr�R PANELS � 2" TU STEEL„ ;ODE 'G' GYPSUM PANELS H STtp` Q ?�1 O.G. �� FI�ERt�IA`-�S0 f INSLC.(R—II) 2Xa woof STLV5 E15 IG' oL. MEN EE., N' STUDS ® 2A" OL. 1�`J'�/S" OGRE/d5 2/SIDE FARTY HALL 0 EXT. WALL DETAIL ®� STUP1a l L7ETA 1 L FIREWALL DETAILS NO. REVISION DATE SCALE:t/9'=7'•-O" REVISE _.....—. 1 REVVISE FN6.PARTY writ TO 10'Md9£ 2/1:/9? FID)F THESE PLANS UNLESS DONE UNDER THE DRAWN BY:D. GODFREY ICENSED ENGINEER OR ARCHITECT IS A so. STATE EDUCATION LAW, RULES, AND REG- DATE: 12 FEBRUARY, 1999 A CLASS A MISDEMEANOR