Loading...
Solar DetailsBREAKING THE 21 % EFFICIENCY BARRIER Q.ANTUM DUO Z Technology with zero gap cell layout boosts module efficiency up to 21.6 %. LOW ELECTRICITY GENERATION COSTS Higher yield per surface area, lower BOS costs and up to 80 watts more module power than standard 144 half-cell modules. ENDURING HIGH PERFORMANCE Long-term yield security with Anti LID Technology, Anti PID Technology1, Hot-Spot Protect and Traceable Quality Tra.Q™. EXTREME WEATHER RATING High-tech aluminium alloy frame, certified for high snow (5400 Pa) and wind loads (2400 Pa). A RELIABLE INVESTMENT Inclusive 12-year product warranty and 25-year linear performance warranty2. STATE OF THE ART MODULE TECHNOLOGY Q.ANTUM DUO combines cutting edge cell separation and innovative 12-busbar design with Q.ANTUM Technology. 1 APT test conditions according to IEC/TS 62804-1:2015, method B (−1500 V, 168 h) 2 See data sheet on rear for further information. THE IDEAL SOLUTION FOR: Ground-mounted solar power plants Q.PEAK DUO XL-G10.2 475-495 ENDURING HIGH PERFORMANCE PRELIMINARY 1045 mm 1308 mm 2216 mm 790 mm 35 mm 4 × Mounting slots (DETAIL A)8 × Drainage holes 3 × 6 mm Frame 1003 mm AU/ EN 454 mm Label 4 × Grounding holes, Ø 4.5 mm 4 × Drainage holes 700 mm 4 × Mounting slots system Tracker (DETAIL B) DETAIL A 16 mm 8.5 mm21 mm DETAIL B 10 mm 7 mm22 mm 1001 mm 350 mm 400 mm EN RELATIVE EFFICIENCYCOMPARED TO NOMINAL POWER [%]YEARS Q CELLS Industry standard for linear warranties* *Standard terms of guarantee for the 10 PV companies with the highest production capacity in 2014 (as at: September 2014) 100 95 90 85 80 155 2520010 98 86 200 400 600 800 1000 110 100 90 80RELATIVE EFFICIENCY [%]IRRADIANCE [W/m²] α [% / K]+0.04 β [% / K]−0.27 γ [% / K]−0.34 NMOT [°C]43 ± 3 475 480 485 490 495 [W]475 480 485 490 495 [A]11.24 11.26 11.29 11.31 11.34 [V]53.58 53.61 53.64 53.68 53.71 [A]10.66 10.71 10.76 10.81 10.86 [V]44.54 44.81 45.07 45.33 45.59 [%]≥ 20.5 ≥ 20.7 ≥ 20.9 ≥ 21.2 ≥ 21.4 [W]356.4 360.1 363.9 367.6 371.4 [A]9.05 9.07 9.09 9.12 9.14 [V]50.53 50.56 50.59 50.62 50.65 [A]8.39 8.43 8.47 8.52 8.56 [V]42.49 42.72 42.94 43.17 43.39 [V]1500 Class II [A]20 C / TYPE 1 [Pa]3600 / 1600 −40 °C - +85 °C [Pa]5400 / 2400 Hanwha Q CELLS GmbH Sonnenallee 17-21, 06766 Bitterfeld-Wolfen, Germany | TEL +49 (0)3494 66 99-23444 | FAX +49 (0)3494 66 99-23000 | EMAIL sales@q-cells.com | WEB www.q-cells.com Note: Installation instructions must be followed. See the installation and operating manual or contact our technical service department for further information on approved installation and use of this product. Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE At least 98 % of nominal power dur- ing first year. Thereafter max. 0.5 % degradation per year. At least 93.5 % of nominal power up to 10 years. At least 86 % of nominal power up to 25 years. All data within measurement toler- ances. Full warranties in accordance with the warranty terms of the Q CELLS sales organisation of your respective country. Typical module performance under low irradiance conditions in comparison to STC conditions (25 °C, 1000 W/m2).Specifications subject to technical changes © Q CELLS Q.PEAK DUO XL-G10.2_475-495_2021-01_Rev01_ENPROPERTIES FOR SYSTEM DESIGN Maximum System Voltage VSYS PV module classification Maximum Reverse Current IR Fire Rating based on ANSI / UL 61730 Max. Design Load, Push / Pull Permitted Module Temperature on Continuous DutyMax. Test Load, Push / Pull ELECTRICAL CHARACTERISTICS POWER CLASS MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, STC1 (POWER TOLERANCE +5 W / −0 W)MinimumPower at MPP1 PMPP Short Circuit Current1 ISC Open Circuit Voltage1 VOC Current at MPP I MPP Voltage at MPP VMPP Efficiency1 η MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS, NMOT2 MinimumPower at MPP PMPP Short Circuit Current ISC Open Circuit Voltage VOC Current at MPP I MPP Voltage at MPP VMPP 1Measurement tolerances PMPP ± 3 %; I SC; VOC ± 5 % at STC: 1000 W/m2, 25 ± 2 °C, AM 1.5 according to IEC 60904-3 • 2 800 W/m², NMOT, spectrum AM 1.5 MECHANICAL SPECIFICATION Format 2216 mm × 1045 mm × 35 mm (including frame) Weight 26.5 kg Front Cover 3.2 mm thermally pre-stressed glass with anti-reflection technology Back Cover Composite film Frame Anodised aluminium Cell 6 × 26 monocrystalline Q.ANTUM solar half cells Junction box 53-101 mm × 32-60 mm × 15-18 mm Protection class IP67, with bypass diodes Cable 4 mm² Solar cable; (+) ≥ 700 mm, (−) ≥ 350 mm* Connector Stäubli MC4-Evo2, Hanwha Q CELLS HQC4; IP68 *Long cables (+) ≥ 1450 mm, (−) ≥ 1450 mm for landscape installation are available upon request. TEMPERATURE COEFFICIENTS Temperature Coefficient of ISC Temperature Coefficient of VOC Temperature Coefficient of PMPP Nominal Module Operating Temperature QUALIFICATIONS AND CERTIFICATES IEC 61215:2016; IEC 61730:2016. This data sheet complies with DIN EN 50380. Certification in process.PRELIMINARY STOREDGE®solaredge.com Optimized battery storage with HD-Wave technology Record-breaking 99% weighted efficiency with 200% DC oversizing Integrated arc fault protection and rapid shutdown for NEC 2014 and 2017, per article 690.11 and 690.12 Embedded revenue grade production data, ANSI C12.20 Class 0.5 Small, lightweight, and easy to install Modular design, future ready with optional upgrades to: DC-coupled storage for full or partial home backup Built-in consumption monitoring Direct connection to the SolarEdge smart EV charger Multi-inverter, scalable StorEdge® solution Single Phase Energy Hub Inverter with Prism Technology for North America SE3000H-US / SE3800H-US / SE6000H-US / SE7600H-US 12-25 YEARWARRANTY SE3000H-US SE3800H-US SE6000H-US SE7600H-US UNITS OUTPUT - AC ON GRID Rated AC Power 3000 3800 6000 7600 W Maximum AC Power Output 3000 3800 6000 7600 W AC Output Voltage Range 211-264 Vac AC Frequency Range (min - nom - max)59.3 - 60 - 60.5(2)Hz Maximum Continuous Output Current 12.5 16 25 32 A GFDI Threshold 1 A Total Harmonic Distortion (THD)<3 % Power Factor 1, adjustable -0.85 to 0.85 Utility Monitoring, Islanding Protection, Country Configurable Thresholds Yes Charge Battery from AC (if Allowed)Yes Typical Nighttime Power Consumption <2.5 W OUTPUT - AC BACKUP(3) Rated AC Power in Backup Operation 2400 3050 4800 6100 W Peak AC Power (<10 sec) in Backup Operation 2700 3400 5400 6900 W AC L-L Output Voltage Range in Backup 211-264 Vac AC L-N Output Voltage Range in Backup 105-132 Vac AC Frequency Range in Backup (min - nom - max)55 - 60 - 65 Hz Maximum Continuous Output Current in Backup Operation 10 12.7 20 25.5 A Peak AC Current (<10sec) in Backup Operation 11.25 14.2 22.5 30 A GFDI 1 A THD <5 % OUTPUT - SMART EV CHARGER AC Rated AC Power 9,600 W AC Output Voltage Range 211-264 Vac AC Frequency Range (min - nom - max) 59.3-60-60.5 Hz Maximum Continuous Output Current @240V (grid, PV and battery)40 Aac INPUT - DC (PV AND BATTERY) Transformer-less, Ungrounded Yes Max Input Voltage 480 Vdc Nom DC Input Voltage 380 400 Vdc Reverse-Polarity Protection Yes Ground-Fault Isolation Detection 600kΩ Sensitivity INPUT - DC (PV) Maximum DC Power 6000 7600 12000 15600 W Maximum Input Current(4)8.5 10.5 16.5 20 Adc Max. Input Short Circuit Current 45 Adc Maximum Inverter Efficiency 99.2 % CEC Weighted Efficiency 99 % 2-pole Disconnection Yes INPUT - DC (BATTERY) Supported Battery Types LG Chem RESU10H Number of Batteries per Inverter 1 or 2(5) Maximum Battery Capacity per Inverter 19.6 kWh Continuous Power Per Inverter 5000 W Peak Power 6900 W Max Input Current @240V 18 Adc 2-pole Disconnection Yes Single Phase Energy Hub Inverterwith Prism Technology for North America SE3000H-US / SE3800H-US / SE6000H-US / SE7600H-US(1) SMART ENERGY CAPABILITIES Consumption Metering Built-in(6) Battery Storage With Backup Interface for service up to 200A; Up to 3 inverters, 15kW backup power, and 60kWh backup capacity EV Charging Direct connection to Smart EV charger ADDITIONAL FEATURES Supported Communication Interfaces RS485, Ethernet, Wi-Fi (optional), Cellular Revenue Grade Metering, ANSI C12.20 Built - in(6) Integrated AC, DC and Communication Connection Unit Yes Inverter Commissioning with the SetApp mobile application using built-in Wi-Fi Access Point for local connection DC Voltage Rapid Shutdown (PV and Battery)Yes, according to NEC 2014 and 2017 690.12 STANDARD COMPLIANCE Safety UL1741, UL1741 SA, UL1699B, UL1998, UL9540, CSA 22.2 Grid Connection Standards IEEE1547, Rule 21, Rule 14H Emissions FCC part15 class B INSTALLATION SPECIFICATIONS AC Output Conduit Size / AWG Range 3/4'' maximum / 14-8 AWG 1'' maximum / 14-6 AWG EV AC Output Conduit Size / AWG Range 3/4'' maximum / 14-8 AWG 1'' maximum / 14-6 AWG DC Input (PV) Conduit Size / AWG Range 3/4'' maximum / 14-8 AWG 1'' maximum / 14-6 AWG DC Input (Battery) Conduit Size / AWG Range 3/4'' maximum / 14-8 AWG 1'' maximum / 14-6 AWG Dimensions with Connection Unit (HxWxD)17.7 X 14.6 X 6.8 / 450 X 370 X 174 in / mm Weight with Connection Unit 26 / 11.8 30.2 / 13.7 lb / kg Noise < 25 dBA Cooling Natural Convection Operating Temperature Range -40 to +140 / -40 to +60(7)˚F / ˚C Protection Rating NEMA 4X © SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 06/2020/V01/ENG NAM. Subject to change without notice. (1) These specifications apply to inverters with part numbers SExxxxH-USS3xxxxx or SE7600H-USSSHxxxx and connection unit model number DCD-1PH-US-PxH-F-x (2) For other regional settings please contact SolarEdge support (3) Not designed for standalone applications and requires AC for commissioning (4) A higher current source may be used; the inverter will limit its input current to the values stated (5) When connecting two LG Chem RESU batteries, each battery must have a different part number (6) For consumption metering current transformers should be ordered separately: SEACT0750-200NA-20 or SEACT0750-400NA-20. 20 units per box. (7) Full power up to at least 50°C / 122°F; for power de-rating information refer to: https://www.solaredge.com/sites/default/files/se-temperature-derating-note-na.pdf Connecting CTs to the Revenue Grade and Consumption Meter Single Phase Energy Hub Inverter with Prism Technology Grid Single Phase Energy Hub Inverterwith Prism Technology for North America SE3000H-US / SE3800H-US / SE6000H-US / SE7600H-US(1) POWER OPTIMIZERsolaredge.com PV power optimization at the module-level Specifically designed to work with SolarEdge inverters Up to 25% more energy Flexible system design for maximum space utilization Fast installation with a single bolt Next generation maintenance with module- level monitoring Meets NEC requirements for arc fault protection (AFCI) and Photovoltaic Rapid Shutdown System (PVRSS) Module-level voltage shutdown for installer and firefighter safety Superior efficiency (99.5%) Mitigates all types of module mismatch losses, from manufacturing tolerance to partial shading Power Optimizer For North America P320 / P340 / P370 / P400 / P401 / P405 / P485 / P505 25 YEARWARRANTY © SolarEdge Technologies Ltd. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 07/2020/V02/ENG NAM. Subject to change without notice. (6) For detailed string sizing information refer to: http://www.solaredge.com/sites/default/files/string_sizing_na.pdf(7) It is not allowed to mix P405/P485/P505 with P320/P340/P370/P400/P401 in one string(8) A string with more than 30 optimizers does not meet NEC rapid shutdown requirements; safety voltage will be above the 30V requirement(9) For 208V grid: it is allowed to install up to 7,200W per string when the maximum power difference between each string is 1,000W(10) For 277/480V grid: it is allowed to install up to 15,000W per string when the maximum power difference between each string is 2,000W Power Optimizer For North America P320 / P340 / P370 / P400 / P401 / P405 / P485 / P505 Optimizer model (typical module compatibility) P320 (for 60-cell modules) P340 (for high- power 60-cell modules) P370(for higher-power60 and 72-cellmodules) P400 (for 72 & 96-cell modules) P401 (for high power 60 and 72 cell modules) P405 (for high-voltage modules) P485 (for high-voltage modules) P505 (for highercurrent modules) INPUT Rated Input DC Power(1)320 340 370 400 405 485 505 W Absolute Maximum Input Voltage (Voc at lowest temperature) 48 60 80 60 125(2)83(2)Vdc MPPT Operating Range 8 - 48 8 - 60 8 - 80 8-60 12.5 - 105 12.5 - 83 Vdc Maximum Short Circuit Current (Isc) 11 10.1 11.75 11 14 Adc Maximum Efficiency 99.5 % Weighted Efficiency 98.8 98.6 % Overvoltage Category II OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Maximum Output Current 15 Adc Maximum Output Voltage 60 85 Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) Safety Output Voltage per Power Optimizer 1 ± 0.1 Vdc STANDARD COMPLIANCE EMC FCC Part15 Class B, IEC61000-6-2, IEC61000-6-3 Safety IEC62109-1 (class II safety), UL1741 Material UL94 V-0 , UV Resistant RoHS Yes INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc Compatible inverters All SolarEdge Single Phase and Three Phase inverters Dimensions (W x L x H)129 x 153 x 27.5 / 5.1 x 6 x 1.1 129 x 153 x 33.5 / 5.1 x 6 x 1.3 129 x 153 x 29.5 /5.1 x 6 x 1.16 129 x 159 x 49.5 / 5.1 x 6.3 x 1.9 129 x 162 x 59 / 5.1 x 6.4 x 2.3 mm / in Weight (including cables)630 / 1.4 750 / 1.7 655 / 1.5 845 / 1.9 1064 / 2.3 gr / lb Input Connector MC4(3)Single or dual MC4(3)(4)MC4(3) Input Wire Length 0.16 / 0.52 m / ft Output Wire Type / Connector Double Insulated / MC4 Output Wire Length 0.9 / 2.95 1.2 / 3.9 m / ft Operating Temperature Range(5) -40 - +85 / -40 - +185 ˚C / ˚F Protection Rating IP68 / NEMA6P Relative Humidity 0 - 100 % (1) Rated power of the module at STC will not exceed the optimizer “Rated Input DC Power”. Modules with up to +5% power tolerance are allowed(2) NEC 2017 requires max input voltage be not more than 80V(3) For other connector types please contact SolarEdge(4) For dual version for parallel connection of two modules use P485-4NMDMRM. In the case of an odd number of PV modules in one string, installing one P485 dual version power optimizer connected to one PV module. When connecting a single module seal the unused input connectors with the supplied pair of seals.(5) For ambient temperature above +85°C / +185°F power de-rating is applied. Refer to Power Optimizers Temperature De-Rating Technical Note for more details. PV System Design Using a SolarEdge Inverter(6)(7) Single Phase HD-Wave Single phase Three Phase for 208V grid Three Phase for 277/480V grid Minimum String Length (Power Optimizers) P320, P340, P370, P400, P401 8 10 18 P405, P485, P505 6 8 14 Maximum String Length (Power Optimizers)25 25 50(8) Maximum Power per String 5700 (6000 with SE7600-US - SE11400-US)5250 6000(9)12750(10)W Parallel Strings of Different Lengths or Orientations Yes