2000-605 TOWN OF OUEENSBURY 742 Bap Road, Queensbury, NY 12804-5902 (518) 761-8201 Community Development - Building & Codes (518) 761=8256 CERTIFICATE CIF OCCUPANCY Permit Number: P20000605 Date Issued: Friday, March 23, 2001 This is to certify that work requested to be done as shown by Permit Number P20000605 has been completed. CID 4 � 1 �3-j Tax Map Number: 523400-054-{IUD-UUD7-049-000-0000 Location: 10 THISTLEWOOD Dr owner: BEN & ANNE CAMPBELL Applicant: BEN & ANNE CAMPBELL This structure may be occupied as a: By Order of Town Board Single Family Dwelling TOWN OF QUEENSBURY Director of Building & Code Enforcement TOWN OF QUEENSBURY 742 Bay Read, Queensbuxy, NY 12804-5902 (518) 761 -8201 Community Development - Building, & Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20000605 Application Number: A,20000605 Tax Map No: 523400-054-000-0007-049-000-0000 Permission is hereby granted to: BEN & ANNE CAMPBELL Owner of property located at: THISTLEWOOD Dr in the Town of Queensbury, to construct or place a Single Family Dwelling informationans and other at the above location in acco and n co pliance withrthe th NYS TJnifortion m Building ether with Codlotesland the Queensbury 2aningereto filed and approved Ordinance. Owner Address: BEN & ANNE C1`1MPBELL Contractor or Builder's Name 1 Address Electrical Inspection Agency Type of Construction: Single Family Dwelling Value : 5 120,000.00 Plans & Specifications 2000-605 1904 sq. ft. single family dwelling wlattached 2 car garage per plot plan, specifications. $244.00 PERMIT FEE PAID - THIS PERMIT EXPIRES: Saturday, August 24, 2002 (Ifs longer period is required, art application for an extension must be made to the code Enforcement Officer of the Tawn of Queensbu before the expiration date.) �'lxur y ugust 24, 2000 Dated at the Tawn f Qu sbu �r,�' for the Town of Queensbury. gIGNED BY Director of Building & Code Enforcement Building Permit Application ication Town pfQLEL'G'12SL7ury - Dept. ofconupusnily Develolvnew, /42 Bay Road, +Qiteensbiir•y, NY 12804 1761-82501 BUILDING & . CODE ENFORCEMENT NOTICERetltiirements prior to issuance A ,permit must bo obtained bcfor© of this lyerntit: PERMIT FILE NO. � ' - '4' 0 s ltoginning etmfdrttcticm. No inspce:titse �'rtlrr, 1lt�tttcL /ictloft iphWAl IT Ft-. & I'A140 ,fit _ a?ct will be ntao until received applicant lots receivc a 'NAIr,10 BUILDING PERMIT•. All Arcs I Use RECJZCATIt7N FEE =$ applicants" spaces on this application 4 MUST be completed eAd• the signature Plairva tg ztaard Action REVIEWCf? Die** of the applicant- must nppear on the sl'lt I subdivisicrrr I "leer r7rrlf.tlnq tees, trf xr• tication form. L.J Recreation Fee Payment Applicant: L i Owner: — Address: mu. s � t�` e +i � f e Address: Phone # ( �� W [E_ pIloilo # _ Property Location: Qi �1 Tlei % s�IetxsoCA act �$f,��,.te(A.Ilk" Tax M:tit Nutntacr Subdivision Name: o t; 4+.)Jf�' section B1cwk l r)t NATURE OF PFCOPCrSEi? WCTItKt ESTIMATED MARKET VALUE OF THE New Building : CONSTRUCTION : $„ UO-1 040C> commercial Addition C ilding : residence / connnercial OCCUPANCY INFORISI►TIC3Nt Alteration to Building : primary Building - residence / commercial __," single ]"amity Dwelling Residence / Commercial Two Family Dwelling no change to exterior 83. ze Family Dwelling Office Other Work ( describe below ) Mercantile Manufacturing Other GROSS AREA OF PROPOSED STRUCTURE * If ADDITlONr what will use ryl/ st T`'�''�loy,o.�,r . . , . . . . . Q Si.� sq . of new, addit; ion be ? : find .Floore • . . . . . . f V , sq . ft * Other Floors . . . . 0 sq . ft . ( not unfinished cellar or basement ) ACCESSORY II1]zLi] Tl3GS : Detached Garage 1 , 2 car TOTAL FLOOR ARCM, : 1304 SQ • FT • �_ Attached Garage 1 , 2 car ' Private Storage Building SIZE OF NEW STRUCTURE * Commercial Storage Building Other FEET XJ g- FELT Foundation Type : �i � - t'�°r^ reAe Will any second-hand or ungraded number of Stories : lumber be used ? if sot for what ? ( habitable space only ) M t> height ( grade to ridge ) : feet- 7CYPr Orr "RATING :SYSTCM : Nuxuber of f iroplacos attd/oL-� Woos stove ( circle ' all hIch applies ) to be installed : C> Clectric / (jjrE> / Gas / Wood Forced Hot Air / Baseboard / Other person responsible for supervision of work as regards to building codes is : Name Addresss hone Builders Liu llr.a...w � C �Jer�� I /') __ �S�Ch - �(�( �._�� 14 Plumber : f n � ea c1 2 _�tv rNtu J IU 74Z Masons Electricians DECLARATION• Please sign below afle'r yors have carefully recld the slatelnent. To the best of my knowledge the statements contained in this application, together with [lie plans and specifleatiotxs submitted, are a true and contplcte statement of all proposed work to be done on the described ltrentises and that all provisions or the Building C.'otic, the 7oninb Ordinance and ail other laws pertairtiing to the prolyoscd work shalt be complied with , whether spccificd or noted, and that such work is autluori7,ccl by the owner. Further, it is understood that I/Nve slt:tll submit prior to a Certificate of Occupancy'or ccrtihcate or Con npliance being issued , an AS BUILT' PX GOT PLAN by a licensed surveyor; drawn to scale, showing actual location or project on premises. C Signature: (owndr, owner's agent, architect, contractor) Application for Perulit — Septic Disposal System Town of Queensbuty 742 Bay1?()ad Qrreensbur;v, N)' 12804 (518) 761-8256 ............. .............. .................,.............. ._....., 1 . OWNER. INFORMATION: Office i3sc Location of installation: - File porxnit No. Tax Map No. I �i Fee Paid Owner's Name*. t Address: _ yK0`jorta P% c& 2. INSTALLER'S NAME : _C+v�! � f v. �5rrs . .vtiC, PHONENO. C! 3. RESIDENCE INFORMATION: (circle year of dwelling, indicate # bed oor ttr(s) and multiply It oJ- bedrooms with applicable gallons per bedroom to equal total daily flow) Year of House: No. of 'Bedroat s x Computation. Total Daily Flow 1980 or older x 150 gailbdrm = 1980 -- 1991 x 130 gallbdrui CTgqf— presen x 110 gallbdrm Garbage Grinder installed yes 1 no Spa or Whirlpool Installed yes / no 4. PARCEL INFORMATION: (circle applicable information &. indicate measurements) To a ra h Soil Nature Ground ater 13e rock or Impervious Material Duo�mcsticlWat r 5u l Flat sand at what depth at what depth p ap a li ( oa U►�feet t kulrwb� talfeet if well; water supply teep slope clay from any septic-system shape other absorption is Jt. depth: other Percolation Test: (To be completed by licensed professional engineer or architect) Rate: minute per inch 5. PROPOSED SYSTEM: For New Couatruction: All individual sewage disposal systems must be designed by a licensed professional engineer or architect (unless installed in a Planning o oard approved ai Tubu�vision). Add 250 gallons to tltc size of tha septic tank and leach field. for each Garbage Grinder, Spa ! Septic Tank: 106 gallon (min. size 1. 000 gal.) Tile Field: each trench D Jt. Total System Length: ft• Seepg a e Pit(s): number of size of each: .l`t• by —� if / 5e Size of Stone to be used: it � depth or thickness ji!et Bed System Size: x Alternative System: length and/or size 6. HOLDING TANK SYSTEM.: (if required) allons 1 TOTAL Capacity: gallons Number of tanks: / Size of each: $ ,Note: Alarm System and associated electrical work must be inspected by a Town approved electrical inspection agency. 7. SIGNATURE & INFORMATION FOR RESPONSIBLE PERSON (please read) For your protection, please note that pursuant to Section 136-29 of the Code of the Town of Queensbury, any permit or approval granted which is based upon or is granted in reliance upon any material misrepresentation or failure to make a material fact or circumstance known by or on behalf of an applicant, shall be void. 1 have read the regulations with respect to this application and agree to abide by these and all requirements of the Town of Queensbury Sanitary Sewage Disposal Ordinance. DateSignatu 8 !yf res:pans b1e ptsrs�n ENERGY CODE COMPLIAHCE APPLICATION TOWN OF 4UEENSBURY , WARREN COUNTY 9000 HEATING DEGREE DAYS COMIDl ia.nce Methods : PART 5 - Acceptaba,e Practice Method 1 & 2 Family Dwellings ( only ) PART 6 * - Thermal Rating Component Trade Offs 1 & 2 Fdmi_ l.y Dwellings ; Multi -Family Dwellings ( 3 stories or less ) PART 4. * - Design by Component Performance Commercial Buildings --Hi. Rise Residential *Requires submission of worksheets APPLICA TT ' S NAME . PROPERTY LOCATION : �t PART 5 METHOD OF COMPLIANCE BY ACCEPTABLE PRACTICE : } i 1 . Gross Floor Area - I C square feet +i 2 . vie of Heat - Electric © il Gas _ Other .�,� r` 3 . Is building mechanidally cooled ? Yes x Ato1 AV r3 er c entage of area of windows and doors Over 17 % � Under 17 % 5 . R-VT?WUEs FOR INSULATION GIVEN sEE-OW MUST CORRESPOND TO tR-V.:LLUES AS Sr C1 r7�] ON PLAINS SUBMITTED : 'It 10 R � ' in a . Roof R �c b . Exterior walls R _ q CV Glazed areas Rj d . Exterior doors R e . Floors over unheated spaces Edge of slab on grade ( heated building ) R � - Basement/ cellar walls ( above grade ) R Basement / cellar walls ( below grade ) Heating/ cooling--ducts -piping in unheated space T-t 61 Ser;ri ce ( domestic ) hot water head- rag c' ev1 Yes No Cocod z orms to minimum efficiency per TEMPERATURE CONTROL MAXIMUM SETTING 1. 400 -- WILL NOT BE '.EXCEEDED Date Phone Nu:nwe= ra Ap ? ican :. s S � na ure P � T_NSpEC � C=.� ' S REMARKS : NiwA RE t 'SM,KNTIAL FINAL INSPECTION REPORT Date inspection request received; Building & Code Enforcement Arrive amlpm 17ep& Dept» of Community Development ,Inspector's burials, 're" of Qiueensbury 742 Bay Road Queensbury. blew York 128M rl�t NAME � DATE LOCATION "TYPE OF STTtL#CTURE COS fS NIA YES NO Chimney HeigbtMT" ventn>irect Vent Location Fresh Air Intake Plumb Vent through roof Rq.df Complete xterior Finish Complete InteriorfExterior Railings 30" to 36" g or I landrails, balconies, i 18 in. or mare T f� �- terior handrails stairs both si 3 or a risers Crrade 20/4 away franc► foundati gar clearance to sill plate Gas Valve shut-off exposed/ ator wit ve grade G Gas Furnace shut-off within 30 f or within ir►e of site Oil funlace shut-off at entrance to FurnaoeJflot Water Heater o Relief Vaive(s) installed Headroom, 6 ft. 6 in. on stairs gaeement stairs, 6 ft_ 4 in. than 3 risers 1landrail exterior stairs both an 3 interior privacy/trinvdoors/ Floor Finish Batinoom/K.itchen watertight interior handrails ` . or more Trailing across window in stairwells smoke Detectors: every level every bedroom outside every bum inter connected Bathroom fans Plumbing fixtures Foundation insulation s/4 hour fire door/door closer Garage. fureproo garage penetrations sealed F:.:^ in sepmate room Pretested (in gar'+a+ge Light ventilation per room_..-.--- - -- - Safet)T glazinglr" or less from floor - Final Electrical Site Planf Variance required Finial Survey Plot Flan As Built Septic System layout required Okay to issue C/C (Cert'f of C;ompliance)_._-.----- - Okay to issue temp. CIO (Certif. of Occupancy)_ ^� Okay to issue permanent CIO (Certif. of Occupancy) xES1QDKN rL+.L FTKAL INSpECTIMN REPORT (3lfice 1Vo. (518) 761-8256 hate inspection request received. 1 Building & Code Enforcement Depart Dept. of Community Development li,rrive Luspector's Initials Town of Queensbury 742 Bay Road Queensbury./r�+5`e4w York 12804 _ L . �P® �lGL DATE 1 F NAME —' LOCATION TYPE OF STRUCTURE NIA YES NO CO1v11vTfS Chimney l4eight/"13" Vent/Direct Vent LorAtion Fresh Air Intake ,r Plumb Vent through roof ��Completc `- v$xterior Finish Complete orlEktenor R ailrngs 30" W 36 or Handrails, balconies, lau 18 in. more Vfntenor Handrails stairs both si 3 more Grade 2% away from four tion S" clearance to sill plate 18" Gas Valve shut-off exposed/ within inc of site grade oas Furnace shut.-off within 30 feet oil Furnace shut-off at entrance to Furnace lo,t Water heater Relief Valve(s) installed } own, 6 ft. 6 in. on stairs Ba.Rement stairs, 6 ft. 4 uix drai4 exterior stairs both sides m than 3 risers Nntenor privacyltrimldoorslmUln en Floor Finish Bathrcwal/KiUhen watertight i in- or more Interior 1-{ dra'Is Ba�lcvmiesli,auding mng across window in stxirrwe]ls_ _^---•— ki oke Detectors: every level every bedroom outside every bedroom / "fi0 ,r inter connected -" r, Bathroom fans Plumbing fixtures Foundation insulation 3/4 hour fire doorldom closer Ggr fawroofin `3 `/4 4- W 11`' ••`��` vdw age penetrations sealed Furnace in separate room. protected (in garage) Light ventilation per room g, ety glazing 18" or 1 s floor anal Electrical '' 12, rV Site planlVarianee required Final Survey Plot Plan si"c /{damd L CJ �As Built Septic System layout required _ Okay to issue CIC (Certif. of Compliance) Okay to issue temp. CIO (Cerlif. of Occupancy)_ Okay to issue Permanent C/o (Certif. of C7C)ccupancy)_.,^---- On RESIDENTIAL F [NAL INSPECTION REPORT Office No. (518) 761-8256 Date inspection request received: Building & Code Enforcement At due M`lM Deparj ' Dept. of Community DevelopmentInspector's itaals fi. Town of rQ,ueensbuty 742 say buoys Queensbury. New York 12804 PE:RN41 T # NAME 2- a T f I3A1L� LOCATION . TYPE OF STRUCTURE V rt� NIA YES NO CoTS Chimney HeightP"W Vent/I7irect Vent i ocimon Fresh Air Intake Plumb Vent through roof Roof Complete ff L $ lc /2�,r� L s Exterior Finish Complete l.01 h i/4�L/t T -Y loterior/Exterior Railings 30" to 36" Exterior Handrails, balconriess landkm 18 in. or moire _ interior Handrails stains both 3 ymore n Grade 2i% away from foundatio ! 8" clearance to sill plate Gas Valve shut-off a for 18" above grade Gas Furnace shut-off within 3 feet or within line of site ' Oil Furnace shut-off at entr to furnace area Funu efflot Water Heater a Relief Valve(s) installed Headroom, 6 ft. 6 in. on 1 Basement stairs, 6 ft. 4 in, r i Handrail exterior stairs both 'des more Phan 3 risers 11 + �J Interior privacy/tritn/doors/ entrance 36" 1 t Floor Finish yr/ Bathroom/Kitchen watertigh Interior handrails Bal 18 in. or more Railing across window in s rwells Smoke Detectors: every level every beotxoartt outside every bedroom inter eonrrectad Bathroom. fans Plumbing fixtures Foundation insulation s/4 hour fire door/door cI Garage fir-o roofm �J A Ajte�' `1 Garage penetrations sealed ,r^�. Furnace in separate morn Protected (in garage) L -4e,&5 i' 3,157' % S Light ventilation per room safety glazing 18" or less from floor Final Electrical Site P1anlVariance required ;, ,; ►` f-- r�- Final Survey Plot flan As Built Septic System layout required Okay to issue C/C (Certif. of Compliance) Okay to issue temp. C/O (Certif of occupancy)_ Okay to issue permanent C/o (Certif of t]ocugauory) s +GENERALINSPECT I N RE RT ( 518 ) 761 - 8256 Town of Queenshury Date inspection request received* Dept. of Community Developwent Bauilding & Code Enforcement 742 Bay Road Arrive elm Depart ��_ Queensbury, NY 12844inspector°s Initials ,// yz a L.v..�nr. !v �?"'�--{-- PERMIT' # r NAME: DATE: + c> a?5 LOCATION: TYPE OF STRUCTURE: RECHECK NIA. YES NO CON D ENTS FovtingslPiers Monolithic Pour Form Reinforeetnent in Place The contractor is responsible for providing protection from n for 48 fours following the of the concrete. Materials for this purpose on si e Foundation/Wallpour orcetneut in Place axndation/DamppV00f T' Backfill Approval Under Sla ..... _� s ' N i+'ti b ur. Lr Plumbing ! I/G c3 , ' Plumbing Ventfvents in ace Rough Piumbin Heating Rough-In Insulation Foundation Walls Interior R Foundation Walls Exterior R Floors R` Walls R Ceiling R- T7uct work or piping in unheated spaces R- Proper vent, Attic Vent Frarnin Jack StudsdleadeTs BracingBt► joist Bangers Jack Posts/Main Beam Air Infi tration Barrier Fire Separation 11 2, 3, hour penetration. Sealed Fire Wall 27 3, 4 hour Firestopping Raymond J Buckley 952 Ridge Road ,Queensbury, New York 12804 Ben Campbell Thistlewood Drive Queensbury, new York 12804 Re: Foundation Condition - Campbell Residence Dear Mr. Campbell, I have been asked by Dale Baldwin to comment on the condition of the foundation for your new residence on Thistlewood Drive. I understand that due to a mistake during the casting of the footings three feet of the south end of the wall between the house and garagedoes not have complete bearing on a concrete footing. Fortunately at this location of the the wall in question ties a flooro and is and the wraced by the ap is a nbn-1 south wallad bearing wall. house and e cellar l would not floor slab and garag recommend and remedial work at this time. Respectfully submitted, .- uckley P.E. L.S. 6r Raymond J BRECEIVED . " DEC 19 2000 T©►N;Aj OF QUEENSSURY .ltgft it BUILDING AND CODE TOWN OF QUEEMSBURY BUILDING a CODE EKFORCEWNT 742 Bay Road Queensbury_H 12804 (518) 761-8256 SEPTIC DISPOSAL SYSTEM INSPECTII"N Name Locationrof= Date i t SOIL TY''P Sand- Loam- aY Results a col ati on est- ( if applicable ) Rate- M nutellnch t TYPE OF SYSTEM: r � ABSORPTION FIELD: Tot 1 Le� �� Length of each trenc ! �— Depth of trenches, __-_ - ---- Size of stone _ SEEPAGE PITS : Num r». Size - _ ft . x ft . Stone size _ � -- PIPINGWz e ,o t/cQ Bldge to Wank �� B Tank to Dist . o — -�4 0 , Dist . Sox to Fi eld/P' a No Parti aT Openings Sealed LOCATIOK/SEPARA IONS : feet Foundation to T nk feet Foundation to bsorpti on eet Separation of its es No onforms as p Plot Plan L TIOM OF S STEM ON PROPER le Rear Left Side - Right Side rout M Front Middle Rear COMMENTS : SYSTEM USE APPROVED : ES NO Arrived= Departed : 4r jjrc�� 15ull di ng Inspector - 1,5r +GENERAL INSPECTION RE�.PQRT ( 518 ) 761 - 8256 Town of Queensbury Date inspection request received: �.. ..�_ Dept, of Community Development Building & Code Enforcement 41 742 Bay Road a+' Arrive l� DepartDeps Queensbury, NY 12804 Inspector's Initials PERNM NAME: .9I �" c. c_ LOCATION:: <' %x,-muel DATE : G TYPE OF STRUCTURE- RECHECK NIA YES NO CO S FootingWNers Monolithic Pour Forms Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following, the placernent of the concrete. Materials for this purpose on site FoundationfWalipour Reinforcement in Place Foundationlpampproofin Backfill Approval plumbing Cinder Slab Plumbing Vent/Vents in Place Z pubin ugh- Ing mtion Foundation Walls Interior R Foundation Walls Exterior R- Floors FL_ Walls R Ceiling R- puci work or piping in unheated spaces R- proper Vent, Attic Vent Framin Jack. Studs/Readers Bracing/Bridging _-- Joist Hangers — Jack Posts/NWn Beam Air Infiltration Barrier Fire Separation i, 2, 3, hour on Sealed sp re Wall 2, 37 4 hc%tr� Firestoppin GENERAL IN,SPEG'7IUN REPORT ( 518 ) 761 - 8255 Town of Queenshury Date inspection request received' Dept. of Community Development 1 Building & Code Enforcement } 742 Bay Read Arrive amlpm Depar[ ak� Queensbury, NY 12804 Inspector's Initials f r. . PERMIT # — ' NAME: C A1ti1z� ' DATE LOCATION: TYPE OF STRUCTURE: REC14EECK NIA YES NO COM1vlENTS I Footings/Piers Monolithic Four Form Reinforcement in Place The contractor is responsible f r providing protection from inS for 4$ hours following the pla men of the concrete. Materials for this purpose on si Foundation/Wallpour Reinforcement in Pled Foundation/Damppra 0fin BacMHI Approval Plumbing Under Slab plumbing Vent/Vents in Place Rough Plumbin Heating Rough In Insulation Foundation Wails Interi R- Foundation Walls E R- Floors R- Walls R- Ceiling - Duct work or piping in unheated spaces R- Proper Vent, Attic Vent F Jack Studs/Readers BracinWBridgin Joist Hangers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1, 2, 3, hour { Fir ration Sealed J� /. � �^y Wall 2, 3, 4 hour r V �} � taPpin Six P_ CTIO v REMOAT ( 518 ) 761 - 8256 Ton of Queensbury Date inspection request received: Dept* of community Development p Building & Code Enforcement Jo �IL� 742 Bay Road Arrive � am/pm. Queens6ury, NY 12$ll4 Inspector's Initi r„ NAME: C,1wm!GG PERMIT �"�� � BATE I s LOCATION: TYPE OF STRUCTURE: RECHECK N/A YES v COMMENTS FootittYys/Piers Monolithic Pour Forth Reinf6rQQMcnt in Place The contractor is responsible for tsraviding protection from Freezing for 48 hours following the placement of the concrete. Materials for this purpose on site FoundationlWallpour Reinforcement in Place Foundation/DampProof Sackfill Approval Plumbing Under Slab plumbing 'Vent/Vents in Place Rough Plumbin Heating Rough' -In Insulation Foundation Walls Interior R- —. Foundation Walls Exterio R- Floors Walls Ceiling Duct work or piping in unbeated spaces R- Proper Vents Attic Vent F Jack Studsl11Ieaders Bracing/Bn Joist Hangers Jack Posts/P Wn Beam Air Infiltration Barrier Fire Separation I, 2, 3, hour Lration Sealed - F Wall 2, 3, 4 ( iroestoppin �'' GENERAL INSPECTION REPQRT ( 518 ) 761 - 8256 Town of Queensbury velop Dept, of Community Ilement ate inspection ;eat received: Building & Code Enforcement 742 Bay Road Ile 'f NY 12"41h eenabury, Arrive am/ ` peetar,s Initials s ,} f RMIT # L NAME: LOCATION i rt 1,_.�� BATE TYPE OF STRUCTURE: RECHECK. N/A NO COMMENTS Monolithic Po, ur Form Reinforcement in Place The contraciiK is responsible for providing prat ion from freezing for 48 hours folid" the placement of the concrete. Materials for this on site Foundation/Wallpour Reinforcement in Place Foundations/1?arc►pparoo 'Backfill Approval Plumbing Under Slab ` �mWng Vent/Vents in Place gh Piumbi Heating Raugli-In Insulation �^- Foundation Walls Int r �- Foundation Walls Ext 'or Floors R- - Wails R- Ceiling R' U #uct work or pipe g in / unheated s R- proper Vent, c ent VF lack rs V ram' trtC� sracing/Bri joist Man ,L�r�c l4�i+� 4c ; T- es / jack Pos in Beam Air Infiltrate arrler____-..----- !�, "� Ir° I Fire Separation 1, 21 3, liorxi P etration Sealed t,� Fi: wall 2, 3, 4 hour ew.10' f Firestoppin TOWN OF QUEENS$URY BUILDING & -"'ObE ENFORC.EiHENT 742 Sly ROAD OUL089SOURY NY 12844 f (513) 761-8256 _.. - ARRIVE. % DEPART : � INSP . i✓_� FINAL InaraCTION REPORT .- RZSIDEtNTZAL DATE INSPE ION REQUEST RECEIVED : NAME LOCATION Drt f�-y1 7."i� � "_ Ir�Lt PERMIT 0 "'',✓ TYPE OF STRUCTURE FOOTINGS FOUNDATION BACKFILL FRAMING ROUGH PLUMBING SEPTIC INSULATION FINAL ELECTRICAL WGODSTOVfE OR PTREPLACE M A CHINLHEY IIEI_. GHTIs V£CNTliEIG _ XLUMSEgG YENT I C ICTERiQR FINISH DECK/LORCH/STLVSJRA I G E A V CE Q ERA G ]xNTtrRTOhii mwlnx..ti�'i.� .0 ORS FINIS BATHJRITCHEN WAS T GR T ER L QR SWEEP L OTHER FLOORS CARPE ED $ C A NCE I N S S O TE S Q N PLUMP G F T RQUNIDAT,ION II A ON _ 94NRACE FIRE P F NG QO SER F L E CT IC E P V RI CE RE , FINAL Si,7RVE"Y Pd,,4';' PLAN_, IS E C O O C f GENERAL INSPEg T NF REPORT ( 518 ) 761 - 8256 Town of Queensbury Dept. of Community Development Date inspection request received: Building & Code Enforcement 742 Bay Road � Queensbury, NY 12804 Arrive am/pm Depart in Inspector's Ini1t�istis NAME: 4 �C� �- PERMIT 4 LOCATION � �2S DATE : 4 !4 T y 'E OF STRUCTURE: RECHECK t �} NIA NO COMMENTS ootin ers I Monoliflu or Form Reinforcement in Place The contractor is responsible for providing protection from ng for 48 'hours following the la e t of the concrete. Materials for this purpose on ite ! Foundation/Wallgour Reinforcement in Pla Foundatioull]am fi Backiill Approval Plumbing Under Slab Plumbing Vent/Vents in aca� Rough Plumbing Heating Rough'In Insulation Foundation Walls Interior R- _ Foundation 'Walls Exterior R- Floors R- Walls R- Ceiling R'p;Ict work or piping in ,+ unheated spaces R- i r [ Mftt - f " ' r C_ aL LJC- •:� r Vent, Attic Vent rand .Tack Stn,d��rreg�prs B racinglBridgin ...,.__ Joist Hangers _ Jack Posts(Main Beam Air Infiltration Barrier Fire Separation I, 2, 3, hour Penetration Sealed Fire Wall 2, 3, 4 hour Firestopping GENERAL LyffEA^TION REPORT ( 518 ) 761 - 8256 Town of Queensbury Dept. of Community Development Date inspection request received: Building di Code Enforcement 742 Bay Road Queensbury, NY 12804. Arrive am/pra Depart Inspector's Initials � NAME: 04 sec_ PERMIT 4 Ot LACATI+DN: �j(t"(/�2� BATE : .1t..- TYPE OF STRUC'I IJR.E: RECHECK N/A YES NO COMMENTS Footings/Piers �I��I Monolithic Pour Form Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site Foundation/Walipour, Reinforcement in Place FoundationA3ampproofing Backrdl Approval Plumbing Under Stab Plumbing Vent/Vents in Place Rough Ptumbin Heating Rough-In Insulation Foundation Walls Interior R- Foundation Walls Exterior R- Floors R- Walls R- Ceiling R- Duct work or piping in 1 unheated Vent, Attic GVe paces R Vent rarni Jack Studs/Headers. Btacing/Bri Joist Hangers Jack PostslMain Beam Air Infiltration Barrier Fire Separation t, 2, 3, )Hour Penetration Sealed Fire Wall 2, 3, 4 hour Firestoppin 34 ,I ( 51 $ ) 761 --8256 GENERAL INSPECTION REPORT Town of Quecnsl�nry DepL of commuoity Development Date inspection request received: Building & Code nforcement 742 Bay Road , v Queensbury, NY liod Arrive am/pm Depart' I ` ^� Inspector's �itials NAME: . p�irr # LOCATION! V-Q . BATERL TYPE OF STRII RECHECK A. YES NO ON 04ENTS tingSlPiers N/ ` f Monolithic Pour Form ,� G Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours Following the placement of the concrete- Materials for this purpose on site mod " / 7 Foundation/Wallpour Reinforcement in Place Foundationli?ampprovfin 13ack6ill Approval Plumbing Linder Slab Plumbing VcntfVents in Place Rough Plumbing Heating Rough4n Insulation Foundation Walls In Foundation Walls Ext r R- _ Floors R- Walls R- Ceiling R- Duct work or ping in unhea R- Proper Ven c Vent Framing lac tuds/I4eaders B ng/Bridging vist F;angers lack Posts/Main Beam Air Infiltration Barrier Fire Separation 1, 2, 3, hour Penetration Sealed Fire Wall 2, 3, 4 hour Firestopping GENERAL LM%eRCTIL7►lV REP ?RT ( 518 ) 761 - 8256 Town of Queensbary Dept. of Community Development Date inspection request received: Building & Come Enforcement 1 742 Bay Road Queensbury, NY 12904 Arrive am/prn ( _ Inspector's Initials NAAI E: `�-- �11P�i�' PFRmrr # LOCATION: DATE TYPE OF STRUG":I:'UIiE: RECHECK NIA YES N C NTS V/00tings/Piers r - - . --Monolithic Pour onm Reinforcentem in Place The contractor is responst providing protection from ng for 48 hours following the pla ent of the concrete. Materials for this purpose on site Foundation/Waltpour. Reinforcement in Place /+ l FoundationManmpproofing ... 'D V oO e> - �4 1 - C �C+ i�-� %/l?.R✓ Backfill Approval Plutnbi ng Under Slab Plumbing Vent/Vents in Place Rough Plumbin Heating Rough4rk Insulation Foundation Walls Interior R Foundation Walls Exterior - T Floors Wails Ceiling R- Duct work or pipi in unheated R- Proper Vent Atti ent Framing Jack St eaeiers , I3racin ri Joist gers Jac ctcfMain Beam x Air tration Barrier Fire Separation 1, 2, 3, hour Penetration Sealed Fire Wall 2, 3, 4 hour Firestoppin GENERAL iNSFEC'7f'1llN REPORT ( 518 ) 761 - 8256 Town of Queensbury Dept. of Community Development Date inspection request received: Building & Code Enforcement 742 Say Road Queensbury, NY 12804 Arrive ��amlpm ,pep 9/)fn Inspector's Initials NAME: PERMIT # I.CICATIO DATE : (� TYPE OF STRUC"CURE; RECHECK N/ YES NO CONWENTS Footings,/PiersMonolithic � Manalitltic Pour Form Reinforcement in Place _ The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete_ Materials for this purpose on site Foundation/Wallpour _ Reinforcement in Place Foun on/Dampprooling_.__ +d,.,S+ ill Approval Plumbing Under Slab Plumbing VentfVents in Place Rough Plum Heating Rough-In Insulation Foundation Walls Interior R- Foundation Walls Exterior R- Floors R- Walls R- Ceiling R- Duct work or piping in unheated spaces R- Proper Vent, Attic Vent Framin Jack S1uds/fleaders BracingMrldgin Joist Hungers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1, 2, 3, hour Penetration Sealed Fire Wall 2, 3, 4 hour Firestoppin GENERAL MS"PECTION REPORT ( 518 ) 761 - 8256 Town of Queensbury Dept. of Community Development Date inspection request received: Building & Code Enforcement 742 Bay Road 11 f Queensbury, NY 12804 Arrive am/prn Depart G inspector's initials NAME; PERMIT # ' ' TYPE CIF LOCATION: DATE RECHECK N/A YE No COMMENTS ootittgS/Piers 4z z 1 Monolithic Pour Formor Reinforcement in Placefirnt " The contractor is res for providing protectionezing for 48 hours fallowinacement of the concrete. Materials for this purpoe Foundation/Wallpour Reinforcement in Place Foundation/Dampproofing Baclfill Approval. Plumbing Under Slab Plumbing 'Vent/Vents i1 ace Rough Plumbing— Heating Rough-In Insulation Foundation Walls In 'or R- Foundation Wafts E erior R- Floors R- Waits R- Ceiling R- Duct work or pipi in unheated spaces R- Proper Vent, Attic Vent FraminA Jack StxxtvE-Ieadex s Bracing/Bri Joist Rangers!! —_ Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1, 2, 3, hour Penetration Sealed Fire Wall 2, 3, 4 hour Firestoppin A Ben Campbell 49 Thistlewood Drive Queensbury, NY 12804 Raymond J Buckley ��** 952 Ridge Road JAN 1 7 2041 Queensbury, NY 12804 TOWN OF P ' BUkLD1NG AND ODi Re: Comment to Foundation Condition Campbell Residence Dear Mr Buckley I received your letter regarding the mistake that was made during construction of my foundation, thank you. I found some of the information to be incorrect, and wanted you to have all the facts to comment on. You state that " three feet of the south end of the wall between the house and garage does not have complete bearing on a concrete footing" Now that you have the pictures you can clearly see that roughly eight feet misses the footing completely and the next ten feet has partial bearing on the footing. I'm enclosing three pictures of the condition that you can have for your file, if you don't mind I would like your comments to reflect the actual condition at hand. Regards, Ben Campbell Phone #'s Work 747- 1361 Home 656-3408 Copy: Dale Baldwin, Town of Queensbury Y: 4 la Raymond J Buckley 952 Ridge Road Queensbury, New York 12804 Bert Campbell Th istlewood Drive Queensbury, new York I2804 Re: Foundation Condition - Campbell Residence Dear Mr. Campbell, I have been asked by Dale Baldwin to comment on the condition of the foundation for your new residence on Thistlewood Drive. I understand that due to a mistake during the casting, of the footings three feet of the south end of the wall between the house and garagedoes not have complete bearing on a concrete footing. Fortunately at this location the wall in question ties into and is braced by the south wall of the house and the cellar floor stab and garage floor and the wall is a non-load bearing wall. . I would not recommend and remedial work at this time. Respectfully submitted, Raymond J Buckley P.E. L.S. e too RECEIVED DEC 19 2000 i "... sfiota fdff IF XE '19' TOW,y OF QUEENSBUM'Y BUILDING AND CC1DE