Signed Inspection Report (Wed Jan 11, 2023 at 155 PM)INSPECTION WORKSHEET (RESFINAL-023110-2023) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number:P20140055-40679 Case Module:Permit Inspection Date:Wed Jan 11, 2023 Inspection Status:Failed Inspector:Dyer, Charles Inspection Type:Residential Final Inspection Job Address:Parcel Number:252 AVIATION RD QUEENSBURY, NY, 12804 301.7-2-26 Contact Type Company Name Name Primary Owner Mitchell, Jon Applicant Mitchell, Jon Granted Permission Mitchell, Jon Agent David F & Pamela Bruno LLC Checklist Item Status General Comments Failed Jon, please make contact with building department as to close this permit out, will need to verify for a final electrical inspection with this project. 518-761-8207 1/11/23 CO in bedrooms w/gas appliances Failed 4 inch Building Number Address visible from road Failed Chimney Height / B Vent / Direct Vent Location Failed Chimney Rain Cap Installed Failed Jan 11, 2023 Page (1) INSPECTION WORKSHEET (RESFINAL-023110-2023) Checklist Item Status Fresh Air Intake Failed Fresh air supply 3' from grade Failed 3" Plumbing Vent through roof minimum 18 inch Failed Outside Spigots have Air Gap Failed Roof Complete / Exterior Finish Complete Failed Platform at all exterior doors Failed Handrail 4 or more risers Failed Guards at stairs,decks,patios 30" + above grade Failed Guard at stairwell at 34" or more Failed Window guards req:<2' above floor/6' above grade - quick release installed Failed Guard at deck, porches 36" or more Failed Handrail Termination at Newell Post or Wall Failed Jan 11, 2023 Page (2) INSPECTION WORKSHEET (RESFINAL-023110-2023) Checklist Item Status Interior/Exterior Railings 34 to 38 Failed Wood deck: 2'+ from grade dia bracing required - H/C ramp compliant Failed 4+ Deck Joist Ledger Connections-24" From Ends Failed Deck Ledger-Bolted per Code Failed Grade away from foundation: 6" down, 10' out Failed 6" clearance to sill plate Failed Gas Shut-off Exposed & Regulator 12" min abv grd Failed HVAC Vent Terminal 10' from Lot Line & Openings Failed Dryer Duct Max Length 35', Labeled Over 35'Failed Interior privacy/trim/doors/main entrance 36 Failed Bathroom / Kitchen Watertight Failed Jan 11, 2023 Page (3) INSPECTION WORKSHEET (RESFINAL-023110-2023) Checklist Item Status Low flow toilet 1.3 gal/flushing cycle - showerhead/faucet Failed Safety glazing: w/in 5' of tub/shower - stairwell win/adj to drs Failed Smoke Detectors:Failed 3' from Kitchens & Baths R314 Failed Every level, Every bedroom Failed Outside every bedroom area Failed Battery backup: _____Failed Inter Connected Failed Carbon Monoxide Detectors:Failed within 10' of all sleeping areas Failed bedroom(s) with gas appliances Failed on all levels w/gas appliances (i.e. furnace)Failed Jan 11, 2023 Page (4) INSPECTION WORKSHEET (RESFINAL-023110-2023) Checklist Item Status Attic Access 22 x 30 minimum Failed Attic Access Insulation = Attic R- Value Failed Attic Access Gasketed Failed Foam in basement/attics covered w/thermal barrier Failed Knee wall/Crawl space 18" x 24"Failed Pull down stairs boxed out and insulated Failed Crawl space/knee wall access insulated & gasketed Failed Bathroom Fans, if no window Failed Plumbing fixtures Failed Backflow Preventors where required Failed Foundation insulation to floor Failed Jan 11, 2023 Page (5) INSPECTION WORKSHEET (RESFINAL-023110-2023) Checklist Item Status Energy Sticker on Elec. Panel:R-Val. & Heating Sys Failed All Hot Water Systems: 3/4" or larger piping R-3 Failed Duct work sealed properly Failed Intake Openings Failed Range Hood 400+ cfm-Fresh Air REQUIRED Failed Blower Door Test Certification Failed HRV or ERV Installed per Bedroom Requirements Failed Floor truss, draft stop- fin base 1,000 sq. ft.Failed Emergency egress below grade Failed Furnace shut-off w/in 30 ft. or w/in line of site Failed Oil Furnace Shut-Off at Entrance to Furnace Area Failed Propane Tank: Proper Setback from Prop Line/Struct Failed Jan 11, 2023 Page (6) INSPECTION WORKSHEET (RESFINAL-023110-2023) Checklist Item Status Furnace/Hot Water Heater operating Failed Low water shut-off boiler Failed Relief Valve ,Heat Trap/Water Temp 110 deg or less Failed Hot water drain pan to indirect waste - receptor or exterior Failed Encl. Stairs Sheetrock Underside minimum ½ Gypsum Failed 1/2" Gypsum or House Wall and Gable Failed 5/8" Type X with Living Space Above Failed 20 Minute Fire Door/Self-Closing Hardware Failed Seals on Garage Doors, esp. Wood Failed Basement stairs closed rise greater than 4 inches Failed Basement wall insulation R- value verified Failed Jan 11, 2023 Page (7) INSPECTION WORKSHEET (RESFINAL-023110-2023) Checklist Item Status Basement Egress: 5s.f. window w/sill or Bilco door Failed Basement ceiling covered 2x8 fl joist or less Failed Jack posts in basement lagged at top and bottom Failed Fireblocking at fl joist 80 s.f. or less Failed Garage Floor Pitched Failed 1/2" Gypsum-Bsmt Ceiling<2x10 Frame/TJI/Fl. Truss Failed Gas Log In Sealed or Glass Enclosure Failed Fin Elect; Energy Saving Light Bulbs 50 Percent Failed CSST/other piping in conduit if buried,if required Failed Final Survey Plot Plan Failed Arc Fault Breaker Habitable Spaces Failed Flex Gas Pipe Bonding Failed Jan 11, 2023 Page (8) INSPECTION WORKSHEET (RESFINAL-023110-2023) Checklist Item Status As Built Septic System Failed Sewer Dept. Inspection Sticker Failed Site Plan / Variance required Failed Flood Plain Certification, if required Failed Fuel Tanks above flood plain elevation Failed Buried Fuel Tanks anchored in flood zone Failed Truss ID Signage Installed at Electrical Meter Failed Electronic as-builts Failed OK to Issue Temporary C/O Failed OK to Issue C/O Failed Jan 11, 2023 Page (9) Dyer, Charles