Loading...
SEP-0256-2022 SEPTIC DISPOSAL PERMIT office Use only APPLICATION Permit#: c`.G—�- 02-rpro -7.Q2Z Town of Queensbury Permit Fee:$ Invoice#: 742 Bay Road,Queensbury,NY 12804 P:518-761-8256 www.gueensbury.net Septic Variance? Y Flood Zone? Y Wetlands? //Yr � r� , (F:R'evi,ewed Project Location: 245 Cleverdale Road Tax Map #: 226.16-1-11 (_ m.�`J��ark_L.t�fj? �—��^CS�Gi—•_, il�1/ RESIDENCE INFORMATION: Year Built Gallons #of bedrooms: X gallons per =total daily flow 1perday bedroom Garbage Grinder Yes No 1980 or older 150 Installed? (choose one) ❑ [� 1981-1991 130 Spa or Hot Tub Yes No 1992-Present 110 Installed? (choose one) El ❑� 7 110 770 PARCEL INFORMATION: Topography Flat Rolling ❑ Steep Slope % Slope Soil Nature ❑ Sand [0 Loam ❑ Clay [J Other, explain: SILT Groundwater At what depth? MOTTLING @ 26", GROUNDWATER @ 44" Bedrock/Impervious material At what depth? GREATER THAN 54" Domestic Water Supply ❑ Municipal ❑ Well VLake' (if well or lake, water supply from any septic system absorption is 160 ft.) Percolation Test Rate.: 6 per minute per inch (test to be completed by a licensed engineer/architect) PROPOSED SYSTEM INFORMATION: Tank size gallons (min. size 1,000 gallons, add 250 gallons for each garbage cylinder or spa/hot tub 1,500 GAL S.T.W/1,000 P.S. @ HOUSE, 1,000 GAL S.T. @ TWO-1 B/R BLDGS System Absorption field w/#2 stone Total length 385 ft.; Each Trench 55 ' ft. Seepage Pit w/#3 stone .How many: ; Size: Alternative System Bed or other type: Holding Tank System Total required capacity? ; tank size ; # of tanks Septic Application Revised April 2021 CONTACT INFORMATION: PLEASE PRINT LEGIBLY OR TYPE, PLEASE INCLUDE AN EMAIL • Applicant: Name(s): Jean Meyer(contact: Martha Noordsy) Mailing Address, C/S/Z: P.O.-Box 72 Cleverdale. NY 12820 Cell Phone: (518)744-8425 Land Line: 518-798-8641 Email: manoordsy@gmail.com • Primary Owner(s): Name(s): Jean T. Meyer Trust Mailing Address, C/S/Z: P.O. Box 72 Cleverdale, NY 12820 Cell Phone: 518-744-8425 (Martha) Land Line: Email: ❑ Check if all work will be performed by property owner only • Contractor: Contact Name(s): Crandall Excavating, Inc. Contractor Trade: Excavation Mailing Address, C/S/Z: 63 Woodchuck Hill Road Lake George, NY 12845 Cell Phone: Land Line: 518-793-0431 Email: "Workers' Comp documentation must be submitted with this application" • Eneineer(s): Name(s):_Hutchins Engineering PLLC Mailing Address, C/S/Z: 169 Haviland Road Queensbury, NY 12804 Cell Phone: Land Line: 518-745-0307 Email: thutchins0hutchinsengineering.com Contact Person for Compliance in regards to this project: Tom Hutchins Cell Phone: Land Line: 518-745-0307 Email: thutchinsC&-hutchinsenaineerina.com NOTES: 1. Alarm system and associated electrical work must be inspected by a Town approved electrical inspection agency; 2. We will no longer allow systems to be covered until such time as an as-built plan is received and approved. The installed system must match the septic layout on file—no exceptions. 3. As- built drawings must be submitted prior to the inspection, if there has been a change to the submitted plans. 4. If, for any reason, the building permit application is withdrawn, 30% of the fee is retained by the Town of Queensbury. After 1 year from the initial application date, 100% of the fee is retained. Declaration: Any permit or approval granted which is based upon or is granted in reliance upon any material representation or failure to make a material fact or circumstance known by or on behalf of an applicant, shall be void. I have read the regulations and agree to abide by these and all requirements of the Town of Queensbury Sanitary Sewage Disposal Ordinance. PRINT NAME: C fir /V _ T 7 SIGNATURE:, �1�/�/,r/t DATE: '—`T (s •24,7- Z- Septic Application Revised April 2021 TOWN OF Q UEENSB URY 742 Bay Road, Queensbury, NY. 12804-5902 Septic System Checklist qA:—i Plan to scale Deceived Deep hole perc test results from engineer/Architect if applicable(Town Approved Engineers and Architects;June 30 to April 15 Town Engineer for unapproved Engineers and Architects) kb All wells on property and adjacent properties shownli� Water line shown Municipal or well 10'separation to any part of system Setback to property lines show 10' or more for any part of system Septic tank and pump stations 10'from foundation 50'from any well/lake/wetland 10' from any waterline �)-KSeptic tank to foundation crawl space/slab on grade, grade in crawl space must be above top of septic tank for0',Separation required (field verification required) '*Septic tank sized for number of bedrooms and add 250 gals forJacuzzi tubs/garbage grinder each 16Leech Field 20' from foundation 100'from any well 10' from water line Seepage pit 150'from well 50'from septic tank P' WeSeepage Pits 3-times diameter apart LN I Septic tank and pump stations over 30 gallons 50' from watercourse or wetland %distance from bottom of trench or system 24 to bedrock or mottli 36 within 1000 of Lake George Leech field 100'from watercourse or wetland %- Toe of mound or bottom of retaining wall 10'from property line 100'from well 20' from Foundation Provide Engineer/Architect stamp for bed or design systems I)ADepartment of Health Approval for all mobile home park new systems Flood Plain requirements f� 2' above established flood elevation to bottom of system &AII tanks anchored or 2' above flood elevation Revised 4/15/2021 COMMONWEALTH ELECTRICAL INSPECTION SERVICE,INC. Main Office 176 Doe Run Road-Manheim,PA 17545 MUNICIPAL CERTIFICATE - ELECTRICAL APPROVAL Permit No S�P� Cert.N A 5 0 0 8 5 Cut-in Card No................................... .�.............. Owner.......................... .. x......... ..................................................................................... Location......2- ..,� 'iZ.......C,t:,c.;s.s,.z.2.!.A.X.......A.Q................................................................... InstallationConsisting of................................................................................................................................... ...... l „y/c,, -.................................................... .................................................................................................................................................................................. InstalledBy..........f'./)........ ti............................................Lic.No................................................. The conditions following governed the issuance of this certificate,and any certificate previously issued i cancelled:- This certificate only covers the electrical equipment and installation conditions as of datc. Upon thi introduction of additional equipment or alterations,application shall be promptly made for inspection. Inspectors of this Company shall have the privilege of making inspections at any time, and if it rules are violated,the Company shall have the right to revoke this certificate. Date.......... -2 q-2 2-............ INSPECTOR Mamh—NFPA 1A_F1 WASTEWATER SYSTEM DESIGN 7-BEDROOM DESIGN SITE LOCATION �'Q %�' fD E P . LOC TO MAP _ (5-B/R HOUSE, 1-B/R BLDG, 1-B/R BLDG) �' ` RevieT(i-- _ - - — DESIGN FLOW - 110 GPD/BEDROOM SYSTEM INSTALLATION NOTES Date: 2, i sYs7FM DESIGN FLOW - 770 cPD CONSTRUCRON SHALL BE AS SHOWN ON THIS DRAWING AND IN ACCORDANCE WITH THE N.Y.S. DEPARTMENT r OF HEALTH INDIVIDUAL HOUSEHOLD SYSTEMS AND AS7M F481 INSTALLATION OF THERMOPLASTIC PIPE AND 5-BEDROOM HOUSE CORRUGATED TUBING IN SEPTIC TANK LEACH FIELDS SEPTIC TANK -PROPOSED 1,500 .GALLON PRECAST CONCRETE PUMP STATION -PROPOSED 1,000 GALLON PRECAST CONCRETE AFTER EXCAVATION OF TRENCHES TO THE DEPTH REQUIRED, THE WALLS AND FLOOR OF EACH TRENCH SHALL LANDS N/F OF BE CLEANED AND RAKED IN ORDER TO LOOSEN SMEARED SECTIONS OF TRENCH. HOLDEN LAKE WATER SUPPLY TWO— 1—BEDROOM BUILDINGS (TWO BEDROOMS TOTAL) PLACEMENT OF AGGREGATE SHALL BE AS SHOWN, AND CARE SHALL BE EXERCISED TO AVOID INCLUSION OF SEP71C TANK - PROPOSED 1,000 GALLON PRECAST CONCRETE FINE GRAINED SOILS AND WASTE MATERIAL IN THE ABSORP71ON TRENCHES LEACH FIELD - PIPE -IN -STONE ABSORPTION TRENCHES THE PIPING SHALL BE LAID AT THE GRADES INDICATED, MAINTAINING STRAIGHT CONTINUOUS GRADES WITHOUT SAGS, HUMPS, SEPARATED JOINTS, OR OTHER UNSUITABLE CONDITIONS. IN RAISED CONRGURA71ON l I- DESIGN PERCOLATION RATE = 6-7 MIN/IN ALL DISPOSAL FIELDS SHALL BE GRADED TO SHED RAINFALL AND DIVERT SURFACE RUNOFF AWAY FROM THE L--- - �_ APPLICATION RATE = 1.0 GPD SF DISPOSAL FIELD. ABSORPTION TRENCH AREA REQUIRED = 770 SF DO NOT USE HEAVY EQUIPMENT WITHIN THE ABSORPTION AREA AFTER TRENCHES HAVE BEEN INSTALLED. LANDS N/F OF 2' WIDE ABSORPTION TRENCH REQUIRED = 385 L.F. CHAMBERLIN INSTALL 7 TRENCHES AT 55 LF. = 385 LF THIS SYSTEM IS DESIGNED FOR WATER CONSERVING FIXTURES AND IS NOT DESIGNED TO ACCOMMODATE LAKE WATER SUPPLY EXTREME WATER USE OR EXTREME ORGANIC LOADING DEVICES SUCH AS JACUZZI TYPE SPAS OR GARBAGE GRINDERS _ POTABLE WATER SUPPLY IS LAKE SUPPLY _ MAINTAIN 10' MIN. SEPARATION BETWEEN WATER SUPPLY ROOF, FOOTING, GARAGE, CELLAR AND SURFACE WATER DRAINAGE MUST BE EXCLUDED FROM THE _ LINE(S) AND ALL WASTEWATER SYSTEM COMPONENTS WASTEWATER SYSTEM. SYSTEM MATERIAL SPECIFICATIONSREVISED I ABSORPTION FIELD AGGREC4TE LANDS N/F OF STONE IS TO BE 3/4" TO 1-1/2" WASHED CRUSHED STONE. HUNT EFFLUENT FILTER I VACANT LOT EFFLUENT FILTER TO HAVE 1116-INCH FILTRATION, POLYLOK PL-122 OR EQUIVALENT. I NO WATER SUPPLY EFFLUENT SEWER PIPE PIPING TO BE 4" SDR-35 OR SCHEDULE 40 PVC INSTALL 107H 1/8" PER FOOT MINIMUM SLOPE. FILTER FABRIC FILTER FABRIC TO BE 4.8 OZ/SY NON -WOVEN SEPARATION FABRIC, TENCATE MIRAFI 14ON OR EQUIVALENT. FORCEMAIN SITE SOILS DATA PIPING TO BE 1-1/2" SDR-11 HDPE OR SDR-21 PVC, PROVIDE POSITIVE DRAINBACK TO PUMP STATION. TES'( pI7' HOUSE SEWER PIPE TP-1 - 71612021 BY TOM HUTCHINS, P.E. PIPING TO BE 4" SDR-35 OR SCHEDULE 40 PVC. INSTALL IMTH 1/4" PER FOOT MINIMUM SLOPE 0-10" - TOPSOIL TOPSOIL LANDS N/F OF 10-21" - LIGHT BROWN SILTY FINE SAND, PLACE 4" MINIMUM TOPSOIL OVER EN71RE BACKFILL AREA. SEED, MULCH, AND ESTABLISH TURF. GUIDOS LAKE WATER SUPPLY TRACES OF CLAY WASTEWATER SYSTEM FILL MATERIAL I 21-28" - OLIVE BROWN GRAVELLY SILT LOAM SEE WASTEWATER SYSTEM FILL MATERIAL NOTES, " 28-54" - OLIVE BROWN FINE SANDY SILT, WASTE/ATER SYSTEM FILL MATERIAL NOTES TRACES OF GRAVEL AFTER REMOVING ORGANICS AND TOPSOIL, PLACE WASTEWATER` SYSTEM FILL OVER THE ENTIRE AREA OF _ - - MOTTLING (BOUNDARY CONDITION) 0 26" PROPOSED ABSORPTION FIELD AND TAPER AREA. SLIGHT GROUNDWATER 0 44" "WASTEWATER SYSTEM FILL" MATERIAL SHALL BE CAREFULLY SELECTED SAND, SANDY LOAM OR SANDY LOAMY LANDS N/F OF PROVIDE 36" M R77CAL SEPARATION TO GRAVEL 10714 M-PLACE PERCOLATION RATE OF 3-5 MIN/INCH AND NO ORGANICS OR OBJECTS OVER 3" IN MONAHAN BOUNDARY CONDITION SIZE. LESS' THAN 10% BY WEIGHT SHALL. BE FINER THAN 0.05mm. AT LEAST 25% OF THE MATERIAL BY I LAKE WATER SUPPLY I WEIGHT SHALL BE IN THE RANGE OF 0.50mm TO 2.0mm. LESS THAN 15%" OF 7HE MATERIAL BY WEIGHT PERCOLATION TEST SHALL BE LARGER THAN A 1/2" SIEVE. PTA P.E. TOM HTE- L WASTEWATER SYSTEM FILL MATERIAL SHALL BE INSTALLED TO PROVIDE MINIMUM OF 3-FEET BETWEEN _ - 6N$ STABILIZED PERCOLATION RATE 6 MINUTES PER INCH ED PERC A7 - SEASONAL HIGH < GROUNDWATER < AND BOTTOM OF ABSORPTION FIELD (3671 BELOW EXISTING GRADE). ; ONLY SYSTEM FILL MATERIAL SHALL BE INSTALLED THROUGHOUT THE ABSORPTION FIELD AREA AND TAPER AREAS WASTEWATER SYSTEM FILL MATERIAL IS TO BE MECHANICALLY STABILIZED IN 12" LIFTS 10711 TRACKED EQUIPMENT PRIOR TO INSTALLATION OF ABSORP7ION TRENCHES INSTALLER' TO NOTIFY ENGINEER OF PROPOSED SOURCE OF WASTEWATER SYSTEM FILL MATERIAL PRIOR TO. TRANSPOR77NG TO 27 , MATERIAL REQUIRED TO PROVIDE COVER OF SEP71C TANK MAY BE NATIVE MATERIAL OR 07HER MATERIAL WHICH 1S NOT NECESSARILY "WASTEWATER SYSTEM FILL." C�� V E MAY 2 O 2022 Fr TAX MAP # 226.16- sBURY Dig FSafely. COMMUNITY DEVELOP New/.york ® Call Before You Dig ■ wait The Required Time N Confirm utility Response Respect The Parks 7 Dig With Cara Dig ® With 1 REVISED PER BLDG DEPT COMMENTS 5/20/2022 800■962-7962 0 ISSUED FOR PERMIT 51312022 www.aig.afelynewrork.com No. Revisions Dote WASTEWATER SYSTEM SETBACK REQUIREMENTS PROPER7Y LINE HOUSE STREAM, LAKE; WATERCOURST WETLAND WELL SEPTIC TANK 10' 10' 50, 50, ABSORPRON RE1D 10' 1 20' 100' 1 100' MAP REFERENCE: of Nt` WASTEWATER SYSTEM PLAN 1. BASE MAP INFORMA71ON FROM "MAP OF LANDS OF MRS �Pf� �p,g T prepared for. RICHARD C. 7EFFT JR.," IN THE TOWN OF QUEENSBURY, ` WARREN ,COUNTY, NEW YORK. DATED NOVEMBER 14, * '�� 2 Meyer Property 197Z PREPARED BY COULTER, MCCORMACK, & N c DICKINSON PROFESSIONAL SURVEYORS & ENGINEERS 245 CleVerddie Road 2. ADD17 ONAL INFORMATION FROM "TOPOGRAPHIC MAP OF rt► I W Town Of QUeensbUly, County of Warren, State of New York LANDS BELONGING TO ROBERT W. SUNDEEN, LOCATED ON WEST SHORE OF RIPLEYS POINT ON LAKE GEORGE,' IN O 7879 Drawn: JRS Checked: GIN Scale: NOTED Date: 8118 2021 THE TOWN OF QUEENSBURY, WARREN COUNTY, NEW O9 169 Havilond Road YORK. DATED SEPTEMBER 7, 1979. PREPARED BY .1 .I COULTER & MCCORMACK LICENSED LAND SURVEYORS. ALTERATION MENT EXCEPT BY Queensbury, NY 12804 291759-01-S 1 A UCENSED 0 ON& ENGINEER IS A (518) - 745-0307 Phone VIOLATION of NYS EDUCATION LAW. Hutchins Engineering PLLC (518) 745-0308 Fax 4" MIN TOPSOIL OVER THE ENTIRE ABSORP71ON FIELD, SEED AND ESTABLISH TURF 1--FILTER FABRIC MIRAFl 14ON OR EQUIVALENT ��- 12" MAX 2" MIN. O �000 SLOPE 6" K� 00� 4" PERFORATED PVC LATERAL,. '�o��Od SLOPE 1/16" - 1/32" PER FT. 3 4" TO 1 1/2" CRUSHED STONE ABSORPTION TRENCH PROFILE SCALE: NTS n n O O� END CAP 6" MIN. SUGGESTED: POLYE7HYLENE EXTENSION SUGGESTED: POLYETHYLENE EXTENSION APPROXIMATE SUGGESTED: POLYETHYLENE SUGGESTED: POLYETHYLENE EXTENSION TO GRADE WI7H TAMPER RESISTANT TO GRADE WITH TAMPER RESISTANT FINISH GRADE EXTENSION TO GRADE WITH TO GRADE WITH TAMPER RESISTANT ACCESS COVER ACCESS COVER TAMPER RESISTANT ACCESS COVER ACCESS COVER 12" MIN. INSTALL FLOAT COVER SWITCHES TO OPERATE PUMP AND MAINTAIN LEVELS AS INDICATED ° .. " 4 PVC SDR-35 • ° 1 8" PER FOOT MIN. 2"F�L SLOPE INLET�9 � 6 MIN. LIQUID LEVEL OUTLET 4" PVC SDR-35 BALL VALVE MIN. SLOPE . • INSTALL VALVES AND UNIONS 1/4"PER FOOT 1/3 SUCH THAT EITHER PUMP CAN BE 4 16" 4"H x18"W SLOT, DEPTH 18 ISOLATED AND REMOVED WITHOUT (2) 4" ELBOWS OF OUTLET MIN. REQUIRING PIT ENTRY WAIER71GHT SLEEVE AND7 OR 6" ELBOW INVERT • SEAL (TYP) —� ° ALARM 3" ABOVE 'PUMP ON' 4. BALL CHECK VALVE LIQUID DEPTH 4 & LAG PUMP ON 30" MIN. ° FLOAT SWITCHES - INSTALL INSIDE 60" MAX. 60-75% OF 25-40X OF PUMP ON PUMP PIT IN LOCA77ON ACCESSIBLE 1,500 GALLON PRECAST TANK VOLUME TANK VOLUME WITHOUT PIT EN7RY CONCRETE SEP77C TANK e MINIMUM 2X WID7H PUMP OFF MAXIMUM 4X NO7H = 16" MIN. 'A . ' ° . • VOLUME OF DOSE TO . A. a . ... 4. , , BE 150f GALLONS 1,000 GALLON PRECAST CONCRETE PUMP STA77ON S-B/R HOUSE SEPTIC TANK & PUMP STATION DETAIL SCALE: NIS BEQ!l16EQ� INSTALL POLYETHYLENE INSTALL POLYETHYLENE EXTENSION .TO GRADE WITH EXTENSION TO GRADE NTH TAMPER RESISTANT ACCESS TAMPER RESISTANT ACCESS COVER (NON' -TRAFFIC AREAS) COVER (NON-7RAFFIC AREAS) 12" MIN. COVER 1/4" PER FOOT G. a. e °. MIN. SLOPE ° Q; °° 4. e n a. d _ a 1/8" PER FOOT 4" HOUSE SEWER 3" MIN. SLOPE r. LIQUID LEVEL FL WATER 7IGHT SLEEVE & 4" EFFLUENT SEWER TO SHARED SEAL (TYR) ° 1,000 GAL PUMP STA77ON 16" 18" I MIN: �+C ; SEPTIC`TANK NOTES a ALL UN17S SHALL COMPLY WITH THE REQUIREMENTS OF ° THE NEW YORK STATE DEPARTMENT OF HEALTH AND SHALL BE OF PRECAST CONCRETE AS MANUFACTURED LIQUID DEPTH BY UTOPIA ENTERPRISES OR EQUIVALENT. 30" MIN. 60" MAX ALL STRUCTURES SHALL BE PLACED ON FIRM,. COMPACT ° SAND OR GRAVEL BASE. WHERE EXISTING SOIL ° CONDITIONS ARE UNSUITABLE, CRUSHED STONE SHALL ° BE PLACED AS NECESSARY TO ACHIEVE A STABLE BASE. OP MINIMUM 2X ND7H SEP77C TANKS INSTALLED IN TRAFFIC AREAS SHALL BE 10 MAXIMUM 4X WIDTH OF EXTRA HEAVY CONSTRUCTION DESIGNED FOR H-20 WHEEL LOADING. ALL JOINTS MUST BE SEALED WITH BUTYL SEALANT. ° ° JOINTS BELOW THE LIQUID LEVEL MUST BE TESTED BEFORE BACKFILUNG. PROPOSED 1,000 GAL. PRECAST CONCRETE SEP7TC TANK 1-B/R + 1-B/R BUILDINGS SEPTIC TANK DETAIL SCALE: NTS TRENCH, (7) REQUIRED AT 55' LONG EACH MATERIAL PRIOR1•TO SURFACE SOILS AND BLEND W17H GRANULAR FILL MATERIAL. (SEE ABSORPTION TRENCH SECTION AND PLACING SYSTEM FILL ABSORPTION FIELD SECTION MECHANICALLY STABILIZE NTH TRACKED EQUIPMENT. PROFILE FOR DETAILS) SCALE: NTS EXTERIOR WEATHERPROOF JUNCTION BOX (IF NECESSARY). SEAL CONDUIT GAS 71GHT. INSTALL CONTROL PANEL IN MIN HOUSE ALL ELECTRICAL WORK TO BE INSPECTED BY A 4" TOPSOIL OVER THE CER77F1ED ELECTRICAL INSPECTION AGENCY PRIOR TO ENTIRE SORP110N FIELD; START-UP OF PUMP ST4770N. SEED &ESTABLISH TURF OVERFILL TO ALLOW BACKFILL FREE OF FOR SETTLEMENT STONES OVER 3" TRANS17ION TO 4" 12" MIN. COVER OUTSIDE OF D-BOX DISTRIBUTION BOX FILTER FABRIC e MIRAFl 140N 2' TRENCH WIDTH 6-12" ° BAFFLE OR EQUAL ° 2" MIN. USE SPEED LEVELERS TO - ASSURE ALL OUTLETS ARE AT EXACTLY THE SAME ELEVA77ON 2" MIN. DROP 2" MIN. °mpg -30 BETWEEN INVERTS 4" PVC SDR-35 SOLID HEADER TO ° 12" MIN. ODi PERFORATED ABSORPnON TRENCH PIPING, 1/8" PER 6" ° d Cd , �DDOo o FOOT.MIN SLOPE Q� 1-1/2" FORCEMAIN 3/4" TO _ 4" PERFORATED PVC LATERAL, CRUSHED STONE SLOPE 1/16" — 1/32" PER FT. ° 1-112" SCH-40 PVC PIPING 1000 GALLON PUMP STATION NOTES ABSORPTION TRENCH SECTION INSIDE WET WELL THROUGH WALL , SCALE. NIS SEAL ALL TANK OPENINGS WATERTIGHT. UNION - LOCATE SUCH THAT UNION CAN BE DISCONNECTED AND PROVIDE AND INSTALL UL LISTED PACKAGED PUMP CONTROL PANEL WITH VISUAL AND AUDIBLE PUMP REMOVED WITHOUT TANK ALARM. INSTALL DUPLEX, DEMAND DOSE CONTROL PANEL INSIDE HOUSE IN ACCESSIBLE ENTRY LOCA770N. DUPLEX PUMPS TO ALTERNATE OPERATION. REDUCING TEE POINTED DOWNWARD INSTALL POWER & CONTROL WIRING TO CONTROLLER WITH ALARM IN HOUSE IN ACCORDANCE WITH 1" BALL .VALVE THROTTLED TO WITH.. MANUFACTURER'S. lNS1RUC7IONS AND NATIONAL ELECTRIC CODE (N.E.C) REQUIREMENTS . ALLOWTRICKLE DRAIN BACK INTO STANDARD CONCRETE SEPTIC TANK NOTES WETWELL PUMP CONTROL AND FLOAT LEVELS TO BE, INSTALLED TO PROVIDE A 150 GALLON DOSE. ALL UNITS SHALL COMPLY WITH THE REQUIREMENTS OF THE NEW YORK GOULDS WEO3M PUMPS EFFLUENT PUMPS TO BE GOULDS PUMPS WE SERIES, MODEL WE03M SUBMERSIBLE EFFLUENT STATE DEPARTMENT OF HEALTH AND SHALL BE OF PRECAST CONCRETE (DUPLEX) PUMP 1/2 HP, 230 VOLT, 1PH AS MANUFACTURED BY UTOPIA ENTERPRISES OR EQUIVALENT. VERIFY EXISTING ELECTRICAL SERVICE PRIOR TO PURCHASING PUMP. ALL STRUCTURES SHALL BE PLACED ON FIRM, COMPACT SAND OR GRAVEL BASE. WHERE EXIS71NG SOIL CON017IONS ARE UNSUITABLE, CRUSHED ALL ELECTRICAL WORK TO BE INSPECTED BY A CERTIFIED ELECTRICAL INSPECTION AGENCY STONE SHALL BE PLACED AS NECESSARY TOACHIEVEA STABLE BASE. PRIOR TO START—UP OF PUMP ST4770N. SEPTIC TANKS INSTALLED IN TRAFFIC AREAS SHALL BE OF EXTRA HEAVY PUMP SELECTION CRITERIA CONSTRUCTION DESIGNED FOR H-20 WHEEL LOADING. ALL JOINTS MUST BE SEALED WITH BUTYL SEALANT. JOINTS BELOW THE ELEVA71ON HEAD= 15 FEET LIQUID LEVEL MUST BE TESTED BEFORE BACKFILUNG DESIRED PUMPING RATE = 25 GPM (APPROX) FRICTION LOSS (1.5" HDPE) = 1.9 PS1/100' EFFECTIVE LENGTH = 175' FRIC71ON LOSS = 3.3 PSI FRICTION HEAD = 8 FEET (2.31 FEET/PSI) TOTAL HEAD = 23' _. USE GOULDS 3885 SERIES WE03M 25 GPM AT 23 FEET 7DH Dig FaSafely. NeWPAYork ■ Cali Before You Dig Wait The Required Time N Confirm Utility Response 0 Respect � � arks 1 REVISED PER BLDG DEPT COMMENTS 5/20/2022 800-962■7962 0 ISSUED FOR PERMIT 51312022 /3 2022 www.dtgsafelynowyork.com APPROXIMATE MAINTAI BETWEEN WATER SUPPLY %ND ALL WASTEWATER Sr. vN 0 RE -DIRECTED TO SOUTH SIDE\ BUILDING SEWIER BY INTERIOR PLUMBING WTH E, ECTOR PUMP IN BASEMEN N 10 LINE LAKE GEORGE CONCRETE SEPTIC G PENETRATION WINDOW LOCA71 GARDEN AREA • �- • * ''' IT�71=hi,'.Ir17��t�1:7aJ_IL1 � _r SCALE. 1 "=40' GRAPHIC SCALE 20 0 10 20 40 80 ( IN FEET ) CONTRACTOR TO FIELD VERIFY LOCATIONS AND DISTANCES RECORD DRAWING DIMENSIONS TABLE CORNER "A" CORNER 18" 1,000 GAL S. T. 33 25' 38. 75' INLET PORT 1,000 GAL S.T. 29.6' 39.5' OUTLET PORT O 55 LF EACH. 385 LF WASTEWATER SYSTEM DESIGN 7-BEDROOM DESIGN I (5-B/R HOUSE, 1-B/R BLDG, 1-B/R BLDG) DESIGN FLOW - 110 GPD/BEDROOM 1 SYSTEM DESIGN FLOW - 770 GPD LANDS N/F OF 5-BEDROOM HOUSE I HOLDEN SEPTIC TANK - PROPOSED 1,500 GALLON PRECAST CONCRETE LAKE WATER SUPPLY PUMP STATION - PROPOSED 1,000 GALLON PRECAST CONCRETE i TWO- 1-BEDROOM BUILDINGS (TWO BEDROOMS TOTAL) SEPTIC TANK - PROPOSED 1,000 GALLON PRECAST CONCRETE L_ _ --- LEACH FIELD - PIPE -IN -STONE ABSORPTION TRENCHES i IN RAISED CONFIGURATION LANDS N/F OF DESIGN PERCOLATION RATE = 6-7 MIN/iN CHAMBERLIN APPLICATION RATE = 1.0 GPD/SF LAKE WATER SUPPLY ABSORPTION TRENCH AREA REQUIRED = 770 SF I 2' WIDE ABSORPTION TRENCH REQUIRED = 385 L.F. INSTALL 7 TRENCHES AT 55 LF. - 365 LF POTABLE WATER SUPPLY IS LAKE SUPPLY I MAINTAIN 10' MIN. SEPARATION BETWEEN WATER SUPPLY i LINE(S) AND ALL WASTEWATER SYSTEM COMPONENTS LANDS N/F OF HUNT VACANT LOT I NO WATER SUPPLY ' SITE SOILS DATA TEST PIT TP-1 - 71612021 BY TOM HUTCHINS, P.E. I. 0-10" - TOPSOIL I 10-21" - LIGHT BROWN SILTY FINE SAND, LANDS N/F OF TRACES OF CLAY GUIDOS 21-28" - OLIVE BROWN GRAVELLY SILT LOAM i LAKE WATER SUPPLY 28-54" - OLIVE BROWN FINE SANDY SILT, i TRACES OF GRAVEL MOTTLING (BOUNDARY CONDITION) O 26" SLIGHT GROUNDWATER O 44" PROWDE 36" VERTICAL SEPARATION TO BOUNDARY CONDITION LANDS N/F OF MONAHAN PERCOLATION TEST LAKE WATER SUPPLY PT-1 - 71612021 BY TOM HUTCHINS, P.E. L_ STABILIZED PERCOLATION RATE: 6 MINUTES PER INCH WASTEWATER SYSTEM FILL MATERIAL NOTES AFTER REMOVING ORGANICS AND TOPSOIL, PLACE WASTEWATER SYSTEM FILL OVER THE EN71RE AREA OF PROPOSED ABSORPTION FIELD AND TAPER AREA. "WASTEWATER SYSTEM FILL" MATERIAL SHALL BE CAREFULLY SELECTED SAND, SANDY LOAM OR SANDY LOAMY GRAVEL WITH IN -PLACE PERCOLATION RATE OF 3-5 MIN/INCH AND NO ORGANICS OR OBJECTS OVER 3" IN SIZE LESS THAN 10% BY WEIGHT SHALL BE FINER THAN 0.05mm. AT LEAST 25% OF THE MATERIAL BY WEIGHT SHALL BE IN THE RANGE OF 0.50mm TO 2.Omm. LESS THAN 15% OF THE MATERIAL BY WEIGHT SHALL BE LARGER THAN A 1/2" SIEVE WASTEWATER SYSTEM FILL MATERIAL SHALL BE INSTALLED TO PROVIDE MINIMUM OF 3-FEET BETWEEN SEASONAL HIGH GROUNDWATER AND BOTTOM OF ABSORPTION FIELD (36"1 BELOW EXISTING GRADE). ONLY SYSTEM FILL MATERIAL SHALL BE INSTALLED THROUGHOUT 774E ABSORPTION FIELD AREA AND TAPER AREAS WASTEWATER SYSTEM FILL MATERIAL IS TO BE MECHANICALLY STABILIZED IN 12" LIFTS WITH TRACKED EQUIPMENT PRIOR TO INSTALLATION OF ABSORPTION TRENCHES INSTALLER TO NOTIFY ENGINEER OF PROPOSED SOURCE OF WASTEWATER SYSTEM FILL MATERIAL PRIOR TO TRANSPORTING TO SITE MATERIAL REQUIRED TO PROVIDE COVER OF SEPTIC TANK MAY BE NATIVE MATERIAL OR OTHER MATERIAL WHICH IS NOT NECESSARILY "WASTEWATER SYSTEM FILL." WASTEWATER SYSTEM SETBACK REQUIREMENTS PROPERTY LINE HOUSE STREAM, LAKE; WATERCOURSE WETLAND WELL SEPTIC TANK 10' 10' 50, 50' ABSORPTION FIELD 10' 20' 100' 1 100' MAP REFERENCE: 1. BASE MAP INFORMATION FROM "MAP OF LANDS OF MRS RICHARD C. TEFFT JR.," IN THE TOWN OF QUEENSBURY, WARREN COUNTY, NEW YORK. DATED NOVEMBER 14, 197Z PREPARED BY COULTER, MCCORMACK & DICKINSON PROFESSIONAL SURVEYORS & ENGINEERS 2. ADDITIONAL INFORMATION FROM "TOPOGRAPHIC MAP OF LANDS BELONGING TO ROBERT W. SUNDEEN, LOCATED ON WEST SHORE OF RIPLEY'S POINT .ON LAKE GEORGE," 1N THE TOWN OF QUEENSBURY, WARREN COUNTY, NEW YORK. DATED SEPTEMBER 7, 1979. PREPARED BY COULTER & MCCORMACK LICENSED LAND SURVEYORS SITE LOCATION LOCATION MAP SYSTEM INSTALLATION NOTES CONSTRUCTION SHALL BE AS SHOWN ON THIS DRAWING AND IN ACCORDANCE NTH THE N.Y.S. DEPARTMENT OF HEALTH INDIVIDUAL HOUSEHOLD SYSTEMS AND ASTM F481 INSTALLATION OF THERMOPLASTIC PIPE AND CORRUGATED TUBING IN SEPTIC TANK LEACH FIELDS AFTER EXCAVATION OF TRENCHES TO THE DEPTH REQUIRED, THE WALLS AND FLOOR OF EACH TRENCH SHALL BE CLEANED AND RAKED IN ORDER TO LOOSEN SMEARED SECTIONS OF TRENCH. PLACEMENT OF AGGREGATE SHALL BE AS SHOWN, AND CARE SHALL BE EXERCISED TO AVOID INCLUSION OF FINE GRAINED SOILS AND WASTE MATERIAL IN THE ABSORPTION TRENCHES THE PIPING SHALL BE LAID AT THE GRADES INDICATED, MAINTAINING STRAIGHT CONTINUOUS GRADES WITHOUT SAGS, HUMPS, SEPARATED JOINTS, OR OTHER UNSUITABLE CONDITIONS ALL DISPOSAL FIELDS SHALL BE GRADED TO SHED RAINFALL AND DIVERT SURFACE RUNOFF AWAY FROM THE DISPOSAL FIELD. DO NOT USE HEAVY EQUIPMENT WITHIN THE ABSORPTION AREA AFTER TRENCHES HAVE BEEN INSTALLED. THIS SYSTEM IS DESIGNED FOR WATER CONSERVING FIXTURES AND IS NOT DESIGNED TO ACCOMMODATE EXTREME WATER USE OR EXTREME ORGANIC LOADING DEVICES SUCH AS JACUZZI TYPE SPAS OR GARBAGE GRINDERS ROOF, FOOTING, GARAGE, CELLAR AND SURFACE WATER DRAINAGE MUST BE EXCLUDED FROM THE WASTEWATER SYSTEM. SYSTEM MATERIAL SPECIFICATIONS ABSORPTION FIELD AGGREGATE STONE IS TO BE 3/4" TO 1-1/2" WASHED CRUSHED STONE. EFFLUENT FILTER EFFLUENT FILTER TO HAVE 1/16-INCH FILTRATION, POLYLOK PL-122 OR EQUIVALENT. EFFLUENT SEWER PIPE PIPING TO BE 4" SDR-35 OR SCHEDULE 40 PVC. INSTALL WITH 1/8" PER FOOT MINIMUM SLOPE FILTER FABRIC FILTER FABRIC TO BE 4.8 OZ/SY NON -WOVEN SEPARATION FABRIC, TENCATE MIRAF7 14ON OR EQUIVALENT. FORCBWN PIPING TO BE 1-1/2". SDR-11 HOPE OR SDR-21 PVC, PROVIDE POSITIVE DRAINBACK TO PUMP STATION. HOUSE SEWER PIPE PIPING TO BE 4" SDR-35 OR SCHEDULE 40 PVC INSTALL WITH 1/4" PER FOOT MINIMUM SLOPE. TOPSOIL PLACE 4" MINIMUM TOPSOIL OVER ENTIRE BACKFILL AREA. SEED, MULCH, AND ESTABLISH TURF. WASTEWATER SYSTEM FILL MATERIAL SEE "WASTEWATER SYSTEM FILL MATERIAL NOTES " A S BUILT I' MA !' RECORD DRAWING R INSTALLATION DATE: OCTOBER 2022 INSTALLED BY - CRANDALL EXCAVATING INC. RECORD DRAWING NOTE: A REPRESENTATIVE OF OUR OFFICE VISITED THE SITE IS MY OPINION THAT TOWN OF QUEENSBURY THE I SYSTEM SS INSTALLED IN 1 GENERAL CONFORMANCE BUILDING & C9?ES,,QjEPT. WTH THE APPROVED PLAN AND THIS RECORD DRAWING FINAL SURFACE FINISHING AND TURF Reviewed Bv: L4W ESTABLISHMENT IS ONGOING Date: _�I'� G. THOMAS HUTCHINS, P.E. 1011212022 TAX MAP # 226.16-1-11 Dig Safely. New/.York ■ Cali Before You Dig 2 RECORD DRAWING 101121202, ■ Wait The Required Tinto ■ Conli m Utility Response 1 REVISED PER BLDG DEPT COMMENTS 512O 202: 0 Care ■ Dig 11Rtii Wft The MarksMarksDig 0 ISSUED FOR PERMIT 5/3/2022 8M962■7962 www.di0safslynewYork.eom No. Revisions Date _4l, ^'F� �' co WASTEWATER SYSTEM PLAN OMAS ti prepared for m z Meyer Property z CO) Q 245 aeverda/e Road Town of Queensbury, County of Warren, State of New York Drawn: JRS Checked: GTH Scale. NOTED Date. 811812021 '�F I 169 Hoviland Road ALTERATION OF DOCUMENT EXCEPT E>Y Queensbury, NY 12804 291759-01-S 1 A LICENSED PROFESSIONAL ENGINEER IS A VIOLATION OF NYS EDUCATION LAW. (518) 745-0307 Phone Hutchins Engineering PLLC (518) 745-0308 Fox