19 MANOR DRIVE UNIT A - Blower DoorDate: City: Queensbury State: NY Zip: 12804 Phone #518-793-7277 Email: City: QUEENSBURY State: NY Zip: 12804 Phone # Email: 1336 square ft. Volume = Blower Door Diagnostics: Ring Inside Temp: 65 Baseline Pressure -50 Pa.A Outside Temp:35 Fan Pressure Pa.B C8 484 cfm@50 New York State Requires builders run a blower door test on new residential buildings to ensure a maximum air leakage of three air changes per hour (ach50). *ACH test results are considerably lower than building standards. Mechanical Ventilation is highly recommended. Blower Door testing performed by: Jack Hall Home Energy Services 165 Bay St Glens Falls, NY 12801 518-412-7505 ID: 1015618 BLOWER DOOR TEST FORM Contractor Address: 6 Holden Ave Location Tested: 19 MANOR DRIVE UNIT A Customer Name: cluteenterprises@gmail.com Ventilation requirements: Building has a HRV installed.YES NO 2/27/2023Contractor: Clute Enterprises, Inc Maximum CFM 50 to achieve less than 3 ACH = 561 Volume: 11220 x 3 = 33660 /60 = 561 CFM @ 50 CFM@50 x 60 / Volume = 2.58 ach Open Actual Flow @ CFM50 = (Height x Living) + (Height x Basement) X 3 / 60 = ACH per Hour