Loading...
1999-645 „.0 Certificate of Occupancy •. Town of Queensbury Warren County, New York • June 12, 2000 • , Date 99645 This is to certify that work requested to be done as shown by Permit No. has been completed. • COMMERCIAL NEW BUILD {BEVERAGE CENTER) This structure may be occupied as a_ 376 DIX AVE. • Location Owner ANCHOR 2 BEVERAGE CENTER • TAX MAP NO. 110 . -1-3 . 31 By Order Town Board • TO F QUEENSBURY” Director of Buildin & Code Enforcement BUILDING PERMIT Town of Queensbury, 742 Bay Road, Queensbury,NY 12804 County of Warren (518) 761-8256 VALUE $ 300000 Building Permit No. 99645 TAX MAP NO.. 110 . -1-3 . 31 Permission is hereby granted to BILL'S BEVERAGE Owner of property located at 376 DIX AVE. in the Town of Queensbury,to construct or place a COMMERCIAL NEW BUILD (BEVERAGE CENTER) at the above location in accordance to application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Owner's Address: DIX AND HIGHLAND AVENUE QUEENSBURY, NY 12804 Contractor or Builder's Name: MACHNICK BUILDERS Contractor or Builder's Address: ONE WEST STREET GREEN ISLAND, NY 12183 Electrical Inspection Agency: Type of Construction: NEW BUILD Plans and Specifications: 8000 SQ FT COMMERCIAL NEW BUILD (BEVERAGE CENTER) AS PER PLOT PLAN SPECIFICATIONS Proposed Use: COMMERCIAL NEW BUILD (BEVERAGE CENTER) $ 120_PERMIT FEE PAD-THIS PERMIT EXPIRES October 29 2001 (If a longer period is required,an application for an extension must be made to the Code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the T wn of Queensbury this 29 Day of October 1999 SIGNED B for the Town of Queensbury Code Enforcement Officer Application for SEPTIC DISPOSAL PERMIT • Town of Queensbury Dept. of Community Development Permit No. Building &Codes Office 742 Bay Road Fee Paid $ Qu e sbury, NY 12804 Location of property for installation:Ti A.nt.Q ( 16tiLeoty AVE: Property Owner's Name: S [ 1% 13EVCitroE Property Owner's Mailing Address: / 66c c,s7 4 ,1fl S renD4 ! y (aa/0 Installer's Name: fl akdi L( & /i LTA Phone # 5 J 2 -6000 . Number of bedrooms (if residential): Total daily flow: `7�. (7) (residential -compute @ 150 gal./bdrm.) Topography: X flat, rolling, steep slope % of slope • Soil Nature: )< sand, loam, clay, other /depth: 6 +rAra,ikiN''c Ground water: at what depth?a9' 'feet / Bedrock or Impervious Material: at what depth? feet Percolation test: not required, ,< required [rate I it^''min.,per inch] Domestic water supply: )( municipal, well, other If domestic water supply is a WELL, water supply from any septic absorption is feet. . PROPOSED SYSTEM Septic tank: 11-506 gallon (minimum size: 1,000 2.1.) Tile,field: each trench �5 feet / Total system Iength: Oi5 feet Seepage pit(s): number of / size each: , ft.by ft. • Size of stone to be used: # / depth or thickness feet • HOLDING TANK SYSTEM: (if required) Number of tanks: Size of each: gafons r-- Alarm system and associated electrical work.to be inspected by a certified agency. J For 3 o protection, please note that pursuant to Section 136-29 of the Code of the Town of Qoeensbury, any permit or acJpLo a1 granted which is based upon or is granted is reliance upon any material misrepresentation or failure to make a material fact or circumstance(mown by or on behAlf of an applicant, shall be void. I have read the regulations with respect to this application and agree to abide by these aDd all requirements of the Town of Queers y Sanitary Sewage Disposal Ordinance. Signature of responsible person: KeGE•WI <)j Date: pi i cfl 1 . ENERGY CODE COMPLIANCE APPLICATION TOWN OF QUEENSBURY, WARREN COUNTY 9000 HEATING DEGREE DAYS Comolia e I e hods: PART 5 - Acceptable Practice Method - GtIV 1&2 Family Dwellings (only) • PART 6* - Thermal Rating - Component Trade Offs OCT 12.1999 1&2 Family Dwellings; Multi-Family U� O�B'�t_ d�3�R�' Dwellings (3 stories or less) TOWN PART 4* Design by Component Performance ,3U11®iNe ,�0 C©�� Commercial Buildings-Hi Rise Residential *Requires submission of worksheets MicNaic4i qui IDOLALic' APPLICANT' S NAME: PROPERTY LOCATION: PART 5 METHOD OF COMPLIANCE BY ACCEPTABLE PRACTICE: 1 . Gross Floor Area - 600 square feet • 2 . Type of Heat - Electric Oil 0Other 3 . Is building mechanidally cooled? No 4 . Percentage of area of windows and doors Over 17% X Under 17% 5 . R-VALUES FOR INSUTLATION GIVEN BELOW MUST CORRESPOND TO R-VALUES AS SHOWN ON PLANS SUBMITTED: �o " '� a . Roof R b . Exterior walls R (7/6 0,011 c . Glazed areas R .jo d. . Exterior doors • R rZ go e . Floors over unheated spaces R . Edge of slab on grade (heated building) R Z-5 a. Basement/cellar walls (above grade) R h . Basement/cellar walls (below grade) R _ . Heating/cooling-ducts-piping in unheated space R 6 . Service (domestic) hot water heating dev ce Conforms to minimum efficiency per code ' Yes No TEMPERATURE CONTROL MAXIMUM SETTING 1400 - WILL NOT BE EXCEEDED Apc' _ca=t ' s Signature Date Phone Number INSPECTOR' S REMARKS: I , BLDG. PERMIT NO, 99-645 APPLICATION FOR A TEMPORARY CERTIFICATE OF OCCUPANCY A TEMPORARY CERTIFICATE OF OCCUPANCY is hereby requested for the property located at; 376 Dix Avenue ( ' _ ° yy ;) for the following uses: Beverage Center (ANCHOR 2 BEVERAGE CENTER) f May 5, 2000 DATE SIGNATURE OF APPLICANT TEMPORARY CERTIFICATE OF OCCUPANCY The TEMPORARY CERTIFICATE OF OCCUPANCY is hereby ( APPROVED ( )DISAPPROVED with the following conditions: Certificate of Occupancy to be issued upon completion of: 1) Installation of 3/4 hour stock room rollup door. 2 ) Installation of heat detector and strobe in the bathroom. 3) Site Plan Issues. TEMPORARY CERTIFICATE OF OCCUPANCY FEE: $10.00 DEPOSIT: 4. 100.00 received on May 5, 2000 Date of Issuance Director of Bldg. & Code Enforcement THIS TEMPORARY CERTIFICATE OF OCCUPANCY EXPIRES 30 DAYS FROM TIIE DATE OF ISSUANCE. NOTE: This Certificate is NOT VALID unless signed by the Director of Bldg.'& Code Enforcement or his designee. - . ._. Building Permit Application , Alp- -,„- . Town of Queensbury - Dept. of Community Development, 742 Bay "� 1 Road, Qrreelisblu y, NY 12804 f 761=8256J • "O. BUILDING & . CODE ENFORCEMENT`'=-' __ ../ NOTICE Requirements prior to issuance • • A permit must be obtained before of this permit: ,_ PERMIT FILE NO. _ qg 64 beginning construction. No inspections will be made until applicant has received El Zoning Board Action PERMIT FEE PAID$ /a eo, co a VALID BUILDING PERMIT. All Area /Use applicants` spaces on this ,application ' RECREATION FEE P , ' MUST be coin 1e 84 �116 signature of the a pl' �rc1 to r on the a� 'Ialtlzi�:g Board Action REVIEWED I3Y. _ <' ld� c. ply SPR / Subdivision /Other r ,kling Inspector p g Recreation Fee Payment Y • • /APicant0:�,�lwh. ii + GtG �u; OAS Owner: �► 1�5 1. _ r ". "r r •e;st 5 ihArSV Si (gif t I S�n•N0 f��.Address: � DCcJ 5-i Air Ny_ 1. i s Amssi - P�l,/U.y_ I ad 1 0 Phone # ( ) ) z - D3eo Phone # Property Location: /1. fvPV leYldhickS. / ° •. Subdivision Name: Tax Map Number •1/0 // _"3 i 31 Section Block T.ot NATURE OF PROPOSED WORK: ESTIMATED MARKET VALUE OF THE New Building: CONSTRUCTION: $ "3O6II0U0 residence commercia Addition to Building. residence / commercial OCCUPANCY INFORMATION: Alteration to Building: Primary Building - residence / commercial Single Family Dwelling Residence / Commercial Two Family Dwelling no change to exterior size . Family Dwelling • Office Other Work (describe below) e Mercantile Manufacturing Other GROSS AREA OF PROPOSED STRUCTURE: 1st Floor e",GL)t� sq. ft . If ADDITION, what will use 2nd .Floor sq. ft. of new addition be? : Other Floors sq. ft. (not unfinished cellar or basement) ACCES• SORY BUILDINGS: Detached Garage 1, 2 car. TOTAL FLOOR AREA: 02 aj6 SQ. FT. Attached Garage 1, 2 car Private Storage Building SIZE OF NEW STRUCTURE: Commercial Storage Building //D FEET X 6jd FEET Other Foundation Type: fills INR-/ C � OPKA 1 Will any second-hand or ungraded '.Number of Stories : i ( lumber be used? If so, for what? (habitable space only Height (grade to ridge) : /h%6/ N feet TYPE OF HEATING SYSTEM: Number of fireplaces and/or woodstove (circle all which a. .lies) ' to be installed: 6 Electric ' 1 / Ga. / Wood rce Hot Air / Baseboard / Other Person respo sible for supervision of work as regards to building codes is: • 6a2. 6 Fri 6ea rNi fSCA''rJ I0' D.90--iiraa6 Name Addresss Phone Builder: f41A61Rvl(II - au)16 C,7P . • Plumber: bl6irI1)L (f'Ca mar.J., Mason: twaCic +.M,Mp7 • Electrician: i...N PCrOtn),NM DECLARATION: Please sign below after you have carefully read the statement. To the best of my knowledge the statements contained in this application, together with the plans`, and specifications submitted, are a true and complete statement of all proposed work to be done on _ . the described premises and that all.provisions of the Building Code, the Zoning Ordinance and all - other laws pertaining to the proposed work shall be complied with, whether specified or noted, and , ' that such work is authorized by the owner. Further, it is understood that Uwe shall submit prior to a '+ Certificate of Occupancyor Certificate of Compliance being issued, an AS BUILT PLOT PLAN by a licensed surveyor; drawn to scale, showing actual location of project on premises. _� y l Signature: U Z c .7 rtikx:i / )/' /�ti lic',,i 0 i° f v;f 7 c LTP, - - . (owner, owner's agent, architect ntracto ) . - - , b • ii 1 ' COMMERCIAL MAL INSPECTION REPORT API Building& Code Enforcement Date inspection request received: l dth Office No. (518)761-8256 Dept. of Community Development Town of Queensbury Arrive part- 742 Bay Road Inspec or's Initi Queensbury,NY 12804 NAME 4/Ackcir PERMIT# — 6/7/5 LOCATION 5''1(& IJ l C , DATE k' TYPE OF STRUCTURE p) N/A DES NDCei�-COMMENTS ChimneyP'B"Vent/Direct Vent location Plumbing Vent Roof Complete Exterior fmish grade complete Interior/exterior guardrails 42 in.platf4 decks hiie+ior/exterior ballasters 4 in.spacing•latform/. Stair handrail 34 in.-38 in. Step risers 7 3/4 in. Main door 44 in. All others 36 in. Lever handles • Exits at grade or platform Canopy to cover req.exit doors Gas valve shut-off exposed&regulator(18',.)above grade Floor bathroom watertight Other floors okay - Hot water relief valve Boiler/furnace enclosure <250,000 BTU N/R 250.000 BTU to 1,000,000 BTU's(1 hour) >1,000,000 BTU's(2 hour) Gas furnace shut off within 30 ft_or within line of s e • Oil furnace shut off at entrance to furnace area Stockroom enclosure(1 hour),3/4 hour door • Storage/receiving/shipping room(2 hour), 1 'h doors 1 '4 hour doors and closers • 4 hour corridor doors and closers Firewalls/fire separation,2 hour,3 hour complete Fire dampers,2 hour fire wall/separation or greater Fire door/shutters 1 '/: hour,3 hour l Ceiling fire stopping 3,000/5,000 sq.ft. Fan shutdown,smoke vents or fan Exit door/panic bars assembly hardware Elevators Elevator signage Handicapped bathroom grab bars/sinks/toil Handicapped batar crng lot signage � ►Pi% Handicapped sery`e counters 34 in.,ch o rn. Handicapped ramp/handrails continuous/12 in.beyond Active listening system and signage assembly space Final Electrical Site Plan/Variance required Final Survey,new structures As-built septic system layout required Okay to issue temp.C/O(Certif.of Occupancy) Okay to issue permanent C/O(Certif.of Occupancy) Okay to issue C/C(Certif.of Compliance) COMMERCIAL FINAL INSPECTION REPORT (-gat qo Building& Code Enforcement Date inspection request received: Office No. (518)761-8256 Dept. of Community Development � ,,•� Town of Queensbury Arrive '_,r__�ar ' vAgri! part 742 Bay Road In _ or's Initials Queensbury, NY 12804 NAME 1\c' GWV-c_k .--e.AS.QA/ PERMIT L16 LOCATIONA AtA DATE TYPE OF STRUCTURE N,t✓� �� N/A YES NO COMMENTS Cni nneyP'B"Vent/Direct Vert location Plumbing Vent Roof Complete Exterior fmish grade complete Dior/exterior guardrails 42 in.platfomt/deccs Interior/exterior ballasters 4 in.spacing platf. Stair handrail 34 in.-38 in. Step risers / 3/4 in. Main door 44 in. All others 36 in. Lever handles Exits at grade or platform Canopy to cover req.exit doors Gas valve shut-off exposed&regulator(18y, above grade Floor bathroom watertight Other floors okay Hot water relief valve Boiler/furnace enclosure <250,000 BTU N/R 250,000 BTU to 1,000,000 BTU's'1 hour) >1,000,000 BTU's(2 hour) Gas furnace shut off within 30 it or w-. in line of site Oil furnace shut off at entrance to fum•ce area Stockroom enclosure(1 hour),'/4 hou door Storage/receiving/shipping room(2 •ur), 1 ''A doors 1 '4 hour doors and closers '.hour corridor doors and closers Firewalls/fire separation,2 hour,3 our complete Fire dampers,2 hour fire wal/sep: •tion or greater Fire door/shutters 1 '/z hour,3 hlur Ceiling fire stopping 3,000/5,0 sq.ft. Fan shutdown,smoke vents or fan Exit door/panic bars assembly hardware Elevators Elevatorenage Handicapped ppped bathroo a sinks/toilets Handicapped b parking lot signage Handicapped servi un errs m.,checkout 36 in. Handicapped ramp/handrails continuous/12 in.beyond Active listening system and signage assembly space Final Electrical '?��� Site Plan/Variance required j�-r�—��-L� , Final Survey,new structures As-built septic system layout required Okay to issue temp.C/O(Certif.of Occupancy) \/(‹et5 Ct> Okay to issue permanent C/O(Certif.of Occupancy) Okay to issue C/C(Certif.of Compliance) • M Ql � GENERAL INSPECTION REPORT (518 ) 761-8256 Town of Queensbury Dept.of Community Development Date inspection request received: , a rr) Building&Code Enforcement 742 Bay Road ao Queensbury,NY 12804. Arriv• A Depa am/ oa®- ` 9 3 • spector's Initia NAME: VC S PERMIT# Q LOCATION: DATE : TYPE OF STRU TUBE: RECHECK N/A YES NO COMMENTS Footings/Piers [ I Monolithic Pour Form Reinforcement in Place The contractor is responsible for lv kI C1 providing protection from ^ p) V i3v\ \ )1 for 48 hours following the placement I- It of the concrete. Materials for this purpose on site tt� Foundation/Wallpour Reinforcement in Place �®� Foundation/Dampproofing 6 _coptL,c Backfill Approval �C Plumbing Under Slab NtW Plumbing Vent/Vents in Place Rough Plumbing Heating Rough-In Insulation Foundation Walls Interior R Foundation Walls Exterior R- Floors R- \AEC\\ Walls R- iling R- Du Duct work or piping in unheated spaces R- Proper Vent, Attic Vent _ L—� 1 •\ \ f J "" laming // Jack Studs/Headers Bracing/Bridging Joist Hangers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1,2,3,hour Penetration Sealed Fire Wall 2,3,4 hour Firestopping FIRE MARSHAL TOWN OF QUEENSBURY -:VACS-2 '' QUEENSBURY, NY 12804 ,, u,, (518) 761-8205 FIRE MARSHAL INSPECTION REPORT REQUEST RECEIVED GI 6 I ZOO 0 NAME _ 11 s v ►�i� �f1C'l�L�i� LOCATION 'T I X A -- PERMIT#v I"I04 6- SCHEDULE INSPECTION ON `j 116 zoo 53 0 AM 4110 APPROVED N/A YES NO EXITS AISLE WIDTHS EXIT SIGNS EMERGENCY LIGHTING FIRE EXTINGUISHERS FIRE ALARM SYSTEM FIRE SPRINKL ` - • TE FIRE SUPPRESSION SYS EM HOOD INSTALLATION INTERIOR FINISHES STORAGE: CLEARANCE • SPRINKLERS CLEARANCE 0 HEATING UNITS REQUIRED SIGNAGE CHIMNEY WOOD STOVE / FIREPLACE ❑MASONRY ❑FACTORY BLT, ❑ROUGH-IN ❑FINAL REMARKS: )/:� OK TO THIS DATE INSPSLIP.PUB IN E TOWN OF QUEENSBURY t �i► BUILDING & CODE ENFORCEMENT OI 742 BAY ROAD QUEENSBURY NY 12804 (518) 761-8256 ARRIVE: DEPART: — INSP: `J FINAL INSPECTION REPORT — RESIDENTIAL DATE INSPECTION REQUEST,� RECEIVED: NAME I I�� vrrr-,1_, LOCATION DATE _ • J`-Ob PERMIT # V161/4 r q�1 TYPE OF STRUCTURE FOOTINGS_ FOUNDATION _ BACKFILL _ FRAMING ROUGH PLUMBING _ SEPTIC INSULATION FINAL ELECTRICAL WOODSTOVE OR FIREPLACE N/A YES NO CHIMNEY HEIGHT/B VENT/HEIGHT PLUMBING VENT , ROOFING EXTERIOR FINISH DECK/PORCH/STEPS/RAIL ; GS RELIEF VALVES FURNACE HO WATER OP Lie' ING INTERIOR TRIM •- f•C DOORS FINISH FLOORS: BATH/KITCHEN WATETIGHT OTHER FLOORS 'SWEE•ABLE OTHER FLOORS CAR•'i'TED STAIR CLEARANCE/RAI'LINGS SMOKE DETECTORS BATHROOM FANS PLUMBING FIXTURES , FOUNDATION INSULATION GARAGE FIRE PROOFING DOOR CLOSERS - FINAL ELECTRICAL SITE PLAN/VARIANCE REO. / VIINAL SURVEY PLOT PLAN `� OK TO ISSUE C/O OR C/C �b v tJ lark r r}�^ L-0.G A•1')b-n D z--„ 11* cif() �� �� FIRE MARSHAL /,�,`., TOWN OF QUEENSBURY QUEENSBURY, NY 12804 Y: (518) 761-8205 FIRE MARSHAL INSPECTION REPORT REQUEST RECEIVED ZctD7 NAME 1 1[3 -i ✓ LOCATION I u' A \cam PERMIT 09 G (46 SCHEDULE INSPECTION ON r C0 1q5 AM S APPROVED N/A YES ' NO EXITS V 1 AISLE WIDTHS EXIT SIGNS EMERGENCY LIGHTIN / FIRE EXTINGUISHERS FIRE ALARM SYSTEM FIRE SPRINKLER SYST M FIRE SUPPRESSION SY TEM N HOOD INSTALLATION INTERIOR FINISHES STORAGE: CLEARANCE 10 SPRINKLERS / CLEARANCE 0 HEATING UNITS U REQUIRED SIGNAGE V CHIMNEY J WOOD STOVE FIREPLACE ❑MASONRY ❑FACTORY BLT. - ❑ROUGH-IN ❑FINAL REMARKS: ❑ OK TO THIS DATE he C ckc in 6aknrconi <.pc:,�r ,Sro.lx, 6 NV011 )11..SN INSPSLIP.PUB I SPEC t COMMERCIAL FINAL INSPECTION REPORT Building& Code Enforcement Date inspection request received: Office No. (518)761-8256 Dept. of Community Development Town of Queensbury Arrive part 7-82 Bay Road Ins Initial Queensbury,NY 12884 iA-C,‘-�1S, Z S?) _\) E_ NAME (31L_(__r.1) P E'JE RAGE PERMIT# 91— LOCATION f 1 xl fl-V'F DATE ' 5'-5—c17 TYPE OF STRUCTURE cinNhm_pc 1 i 0 1_0(- N/A YES NO COMMENTS Chimneyf'B"Vent/Direct Vent location I .�,rE-` Plumbing Vent ` �� V Roof Complete N..// Exterior finish grade complete �/ Interior/exterior guardrails 42 in.platform/4,. ' v/ Interior/exterior ballasts 4 in.spacing platfi decks t// Stair handrail 34 in.-38 in. ✓ Step risers 73 in. ✓ Main door 44 in. i / All others 36 in. lever handles \ V/ Exits at grade or platform / Canopy to cover req.exit doors Gras valve shut-off exposed&re rlator(18• :i sve grade V Floor bathroom watetight Other floors okay / Hot water relief valve V/ Boiler/furnace enclosure ✓ <250,000 BTU N/R 250.000 BTU to 1,000,000 BTU's(1 hour) • >1.000,000 BTU's(2 hour) Gas furnace shut off within 30 fl-or within line of s e / Oil furnace shut off at entrance to furnace area V - / ck Storoom enclosure(1 hour),'/.hour door ! V 3/1-i >-io �� u? - UQ D00�- QM-Star age/receiving/shipping room(2 hour), 1 1/2 doo �// I '4 hour doors and closers ]4 hour corridor doors and closes - ' Firewalls/fire separation,2 hour,3 hour complete ./, Fire dampers,2 hour fire wall/separation or greater V/ Fire door/shutters 1 '/z hour,3 hour ✓/ Ceiling fire stopping 3,000/5,000 sq.ft. ✓ Fan shutdown,smoke vents or fan i Exit door/panic bars assembly hardware \/ Elevators Elevator signage Handicapped bathroom grab bars/sinks/toilets Handicapped bath/parking lot signage / 00 PkRV--Nt t� 6t(j1j Fp� I`� j N!h Handicapped service counters 34 in.,checkout.36 in. �/ • `q Hand_ ed ramp)handrails continuous/12 in.beyond i V•-FI zJl.6 t-k P�\3\16 O �E Mti Active listening system and signage assembly space - Final Electrical Site Plan/Variance required �10 to t--� PRO 0 C�7-6P 6 t RIRK) Final Survey,new structures A C:�t reD G �j RRIG P-Ou (x1L L I F' ) As-built septic system layout required J rt))� C/O(Certif.of Occupancy) �T -1� - Okay to issue temp. ( Okay to issue permanent C/O(Certif.of Occupancy) • Okay to issue C/C(Calif.of Compliance) ru-cl- L-W,V IWG .1 t 1La Vr7JJ 4V nrlal cr..JJnrl. , 11 •_%'hL1C_J b1 Q � E Qp Overhead Door Company of Aineerdern,inc. 0 403 W.Mein Street d�a aid t9Bf Post Office Box 355 Amsterdam,New York 12010 Telephone:(518)842.737o FAX NUMBER 518 842-1625 FAX MESSAGE TOTALING. 9 .,PAGES INCLUDIN THIS COVER DATE: 5/2/0 0 TO: BILL PETROSINO - BILL';S BEVERAGE FROM: LOU MOSHER • REF: ai R E DOOR - GUN"S--F A L1 S S T O R E We' ve had confirmation that the f .re Jocr fo. your Glens Falls store will be shipped 5/5/C.: . The delivery to our warehouse will arol a-Liy be the ' middle or end of next week and es soot.: ar we ;ave it, we ' ll call to arrange installation . • IF THIS TRANSMISSION IS INTERRUPTED OR INC kT,41PLETE PLEASE CALL 518-842-7370 I a distributor of Ove,t-.ca Doytr Corp:*ation products == APR-18-00 TU.E 13 : 6 OHE Co AMSTERDAM 518842 '62,'' P. E2 7 QUOTATLON I Igo, 27876 The Overhead Door Company of Amsterdam, !rco 403 West Main Street - Post Office Box 36. - A D D- Amsterdam, New York tdoetykkasime019,9/t FAX Number 518 842-1625 JOB NAME GLENS FALLS STORE, • _ I DATE 04 / 1 S /00 ADDRESS NUMBER - i TO: B I L L 'S BEVERAGE IARCHITECT — 1 Willow Street Amsterdam, New York 12010 WE PROPOSE TO FURNISH: and install -- One (1 ) Model FD2 fire door Opening size 7 '0" x 8' 0" 'Tan paint (Gray available) 160° fusible link Chain hoist operation TERMS: Net 30 - Tax included Total Amount $ 1 880. CO By: r Laui ,,„Moshe r I It r ahead or om of AmSL rdatn,Inc. Cu owner 81snature Pi/ GENERAL INSPECTION REPORT ( 518 ) 761-8256 Town of Queensbury Dept.of Community Development Date inspection request received: .) 3/dzia85 Building&Code Enforcement 742 Bay Road Queensbury,NY 12804. Arrive t 1am ��Depart r • Inspector's Initial c - NAME: Les o-ere 1715 PERMIT# LOCATION: DATE: TYPE OF STRUCTURE: C:() C RECHECK N/A YES NO COMMENTS Footings/Piers - I I I Monolithic Pour Form Reinforcement in Pla•- The contractor is sponsibli for providing protect in from • :ezing 48 hours folio r' g the pl.cement of t le concrete. Materia for this pu q••se on si e Foundati•r allpou Reinforceme 'n P1.ce Foundation/Damppr•_•fin Backfill Approval Plumbing Under Sla Plumbing Vent/Vent in Place Rough Plumbing Heating Rough-In Insulation Foundation Walls I tenor R- Foundation Walls E, erior R- Floors R- Walls R- Ceiling R- Duct work or pipit g in unheated spaces` R- Proper Vent,Attic Vent Framing Jack Studs/Headers Bracing/Bridging Joist Hangers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1,2,3,hour Penetration Sealed ` ire Wall 2,3,4 hour IV/ Firestopping t/ FIRE MARSHAL -may- TOWN OF QUEENSBURY j QUEENSBURY, NY 12804 t (518) 761-8205 FIRE MARSHAL INSPECTION REPORT REQUEST RECEIVED NAME 1\L.S 30V- LOCATION 7 (0 ( _ PERMIT I`(o J SCHEDULE INSPECTION ON &M APPROVED N/A Y)Ee NO EXITS AISLE WIDTH EXIT SIGNS R e. EMERGENCY LIGHTING :ARC FIRE EXTINGUISHERS FIRE ALARM SYSTEM 1 e PJ 5 FIRE SPRINKLER S SI 1 EM,,---7 FIRE SUPPRESSION SYSTEM HOOD INSTALLATION INTERIOR FINISHES STORAGE: CLEARANCE TO SPR NKLERS CLEARANCE TO HEA ING UNITS REQUIRED SIGNAGE CHIMNEY WOOD STOVE FIREPLACE ❑MASONRY ❑FACTORY BLT. e-Th ❑ROUGH-IN ❑FINAL REMARKS: ❑ OK TO THIS DATE (j) Io8 ( I) 8C INSPSLIP.PUB NS TOR J ) --)a- g a-a-0 COMMERCIAL FINAL.INSPECTION REPORT Building& Code Enforcement Date inspection request received: Office No. (518)761-8256 °�%4\.11) J Dept. of Community Development 0 \\C�� Town of Queensbury ArrivelQ4., wpm Depart` 742 Bay Road ector's Initial �1 In p Queensbury, NY 1r2804 NAME ` 1 SPX-Ae PERMIT# — LP HLOCATIO S G N 1 ' LL.1Z DATE D-)t) TYPE OF STRUCTURE eN1,, ; N/A YES NO COMMENTS ChimneyP'B"Vent/Direct Vent location Plumbing Vent — AP1.-his C)Eyr-\ 5 Roof Complete �� �K� Exterior fmish grade complete F1�ET�p1 4 �1�. Interior/exterior guardrails 42 in.platform/decks CALL S)e pJE 10,.L Interior/exterior ballasters 4 in.spacing platform/decks \ C M �.5� - — Stair handrail 34 in.-38 in. \ PLC\ �.- ,J\ tY le e_OOIA 1 eC Step risers 7 Y.in. A o F_pATT D o 1. A P�oc-V-q F (R-E_ Main door 44 in. All others 36 in. �`Cag\tLC� Lever handles1t.11JC� A L i_. F11 �,� Exits at grade or platform L _ Canopy to cover req.exit doors ` `��1—\-- 1j `LLQO y` Gas valve shut-off exposed&regulator(18 in.)abov u .: p o 1 Floor bathroom watertight` u3i 1 �LL v� flOoz Other floors okay �_____, _ Hot water relief valve — L N MQ' E\E_ ‘--kiN t� 1C_c; Ber/frnaceenclosure 13- , �� ���<250,000 BTU N/R 19\PW . (-.rt`k 250.000 BTU to 1,000.000 BTU's(1 hour e \I 6TP Lk- KA V3D\C.-M)PEES q VDOr >1.000,000 BTU's(2 hour) Gas fuace shut off within 30 ft.or within lin,.of site � `�1��� film. Oil furnace shut off at entrance to furnace area — 1 c�t_>_ C �T`Stockroom enclosure(1 hour),'/.hour door t \E_ _ •tA �f\► O LE (f a_ Storage/receiving/shipping room(2 hour), 1 ' doors 1 'h hour doors and closers ��� �F1 C��t . '.hour corridor doorsand closers •�•'C� Firewalls/fire separation,2 hour,3 hour co .'ete Fire dampers,2 hour fire wall/separation or LAter `� \ 1 ��(�� p(�—���(� FAIL � Fire door/shutters 1 '/2 hour,3 hour — \-`et 13O 1C _�PP Ceiling fire stopping 3,000/5,000 sq.ft. Jr tJ© W Vi t3 ' Fan shutdown,smoke vents or fan r Exit door/panic bars assembly hardware — 1'-E\1EZ \--Ep‘1Q�J3 Di. p \c Elevators C3f\T-t-erut--\ bL r Elevator signage Handicapped bathroom grab bars/sinks/toilets _ C"0,VA 1 L— c o 4 be FzF t`1-- Handicapped bath/parking lot sign �LvMS3t�� Handicapped servicecounters 34 in.,.,checkout 36 in. kzotz bot%. � Handicapped ramp/handrails continuous/12 in.beyond .A.ctive listening system and signage assembly space Final Electrical 1�RL_ �\�� Site Plan/Variance required VA PR--- ‘-‘1- 1 Final Survey,new structures CV0 . \L ?� As-built septic system layout required_ • Okay to issue temp.C/O(Certif.of Occupancy) Okay to issue permanent C/O(Certif.of Occupancy) ELy 1,,,\kR.\-1 Okay to issue C/C(Certif.of Compliance) • COMMERCIAL FINAL INSPECTION REPORT Building& Code Enforcement Date inspection request received: Office No. (518)761-8256 Dept. of Community Development Town of Queensbury Arrive/( 70 am/pm Depart am/pm 742 Bay Road Inspector's Initials p11 Queensbury,NY 12804 q / NAM Er i 1 IE PERNIlT# L lP LI'5 LOCATION 7 j � DATE 1a -/3— f()C TYPE OF STRUCTURE N_5(e)A l N/A YES NO COMMENTS Chimney/"3"Vert/Direct Vent locati Plumbing Vent Roof Complete Eire for fmish grade complete Interior/exterior guardrails 4 in.platform/ hior/exterior ballasters 4• .spacing platf decks Stair handrail 34 in.-38 in. Step risers 7 3/4 in. Main door 44 in. All others 36 in. Lever handles Exits at grade or platform Canopy to cover req...exird-Tors Gas valve shut-off exposed t4c regulator(18 in.)above grade Floor bathroom watertight Other floors okay Hot water relief valve •• Boiler/furnace enclosure_ <250.000 BTU N/R 250.000 BTU to 1,000, 00 BTU's(1 hour) >1,000,000 BTU's(2 h ) Gas furnace shut off within 0 ft.or within line of site • Oil furnace shut off at ce to furnace area Stockroom enclosure(1 ho ),N hour door - Storage/receiving/shipping m(2 hour), 1 '/2 doors I 'i hour doors and closers '4 hour corridor doors and losers _Firewalls/fire separation,2 our,3 hour complete Fire dampers,2 hour fire wall/separation or greater Fire door/shutters 1 '/2 hour,3 hour Ceiling fire stopping 3,000/5,000 sq.ft. Fan shutdown,smoke vents or fan Exit door/panic bars assembly hardware Elevators Elevator signage Handicapped bathroom grab bars/sinks/toilets Handicapped bath/parking lot signage Handicapped service counters 34 in.,checkout 36 in. •Handicapped ramp/handrails continuous/12 in.beyond .Active listening system and signage assembly space Final Electrical Site Plan/Variance required _ Final Survey,new structures .As-built septic system layout required 'Okay to issue temp.C/O(Calif.of Occupancy) tV/1 • Okay to issue permanent C/O(Calif of Occupancy) ©043^ /4/'"1 • Okay to issue C/C(Certif.of Compliance) 3 p GENERAL INSPECTION REPORT ( 518 ) 761-8256 Town of Queensbury Dept. of Community Development Date inspection request received: Building& Code Enforcement 742 Bay Road n Queensbury, NY 12804 Arrivet-Vacp"`"�/Depart'"ti' Inspector's Initi NAME: PERMIT# LOCATION: � 1 y�C DATE : _ D TYPE OF STRUCTURE: N ) RECHECK N/A YES NO COMMENTS Footings/Piers I I Monolithic Pour Form Reinforcement in Place The contractor is respo ible for providing protection f om freezing for 48 hours followii g the placcn nt of the concrete. Materials for this pu'Ilse on sits Foundation/Wallpoi Reinforcement in P ace - - Foundation/Damp.,s. ing - - • - Backlill-App • al Plumbing Under S,ab Plum 'ng VenUV•� is in Place_ � n aJ ugh Plumbing �j �� � �� �%� L Heating Rough-In Insulation e ©- \ (:›A Foundation W lls Interior R- Foundation vU �t W lls Exterior R- Floors R- Walls R- Ceiling R- Duct work or piping in unheated spaces R- Proper Vent, Attic Vent_ Framing_ Jack Studs/Headers Bracing/Bridging Joist Hangers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1, 2, 3, hour Penetration Sealed Fire Wall 2, 3,4 hour Firestopping GENERAL INSPECTION REPORT Town of Queensbury Dept. of Community Development Date inspection request received: Building& Code Enforcement 742 Bay Road Queensbury,NY 12804 Arrive -j /pm Depart Inspector's Initi NAME: j t PERMIT# LOCATION: \D>y . q\\F DATE : '-f -'j TYPE OF STRUCTURE: c_tm t T RECHECK N/A YES NO COMMENTS Footings/Piers Monolithic Pour Form Reinforcement in Place The contractor is responsib for providing protection from in for 48 hours following the •I ace► ent of the concrete. Materials for this purpose on s Foundation/Walipour Reinforcement in Pl. - Foundation/Dampproo+ng Back ill Approval Plumbing Under Slab Plumbing Vent/Vents in Place Rough Plumbing Heating Rough-In Insulation Foundation Walls Interior I'- Foundation Walls Exterior R- Floors R- Walls R- Ceiling R- Duct work or piping in unheated spaces R- Proper Vent, Attic Vent Framing Jack Studs/Headers Bracing/Bridging Joist Hangers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1, 2, 3, hour Penetration Sealed Fire Wall 2, 3, 4 hour l M Firestopping 1 G0 GENERAL INSPECTION REPORT ( 518 ) 761-8256 Town of Queensbury Dept. of Community Development Date inspection request received: Building& Code Enforcement 742 Bay Road • Queensbury, NY 12804 6.Arrive �/ .• Depart e. n Inspector's Initia r,'� VreatigAt — NAME: r ! r, PERMIT# !1 w LOCATIO : RAt, % DATE : 3 -3 O TYPE OF STRUCTURE: (\3 p >-ex Q.„-S RECHECK N/A YES NO COMMENTS Footings/Piers Monolithic Pour Form Reinforcement in Place The contractor is responsible f providing protection from frc ring for 48 hours following the pl•cement of the concrete. Materials for this purpose on lie Foundation/Wallpour Reinforcement in place I j Foundation/Dampp oofing Backfill Approval Plumbing Under Slab Plumbing Vent/Vents in Place Rough Plumbing Heating Rough-In Insulation Foundation Walls Interior 1t- Foundation Walls Exterior R- Floors R- Walls R Ceiling Duct work or piping in unheated spaces Proper Vent, Attic Vent _ Framing_ Jack Studs/Headers Bracing/Bridging Joist Hangers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1,2, 3, hour Penetra ' Sealed all 2, 3,4 hour restopping � � -�Q *Ni\i\ GENERAL INSPECTION REPORT ( 518) 761-8256 Town of Queensbury Dept.of Community Development Date inspection request received: Building&Code Enforcement 742 Bay Road Queensbury,NY 12804. Arrivel,b-- /pit Depart Inspector's NAME: PERMIT# - J LOCATION: 7 6 _ X , DATE: _ 0 TYPE OF STRUCTURE: (v e A- RECHECK N/A YES NO CONTS Footings/Piers I I I Monolithic Pour Form fi g PIA Reinforcement in Place �/ The contractor is res. nsib - for providing protection fr.m fr-- ing for 48 hours following i e pla ement of the concrete. Materials for this purpose o si Foundation/Wallpour Reinforcement in ' - Foundation/Dampproofing - ---- - --- -- -- Backfill Approval Plumbing Under Slab Plumbing Vent/Vents in Place Rough Plumbing Heatin Rough-In Cation-- Foundation Walls Interior R- Foundation Walls Exterior R- Floors R- Walls R- Ceiling R- Duct work or piping in unheated spaces R- Proper Vent,Attic Vent Framing Jack Studs/Headers Bracing/Bridging Joist Hangers Jack Posts/Main Beam Air Infiltration Barrier_ Fire Separation 1,2,3, hour Penetration Sealed Fire Wall 2,3,4 hour Firestopping /CA 1 GENERAL INSPECTION REPORT Town of Queensbury Dept. of Community Development Date inspection request received: i4.1-`xl Building& Code Enforcement 742 :ay Road �� Queensbury,NY 12g®4 Arrive yin Depart r Inspector's Initials NAME: 6-1,4)!' a (). (f' PERMIT# LOCATION: ,4v-- DATE : ea, . s ) TYPE OF STRUCTURE: ' a RECHECK C A I y; ,i c ,k or - ( N/A YES NO COMMENTS Footings/Piers Monolithic Pour Form ‘)i-\L7.\,�cn ��t-k- ii u - Reinforcement in Place \ ��C'�jC-i 1� The contractor is responsible for \ %—\EC� -TO . providing protection from freez. g � �� �' l l ' -t k for 48 hours following the place ent 0 oE_ '�� t LteL, of the concrete. L .Deo Materials for this purpose on site / s Foundation/Wallpour c t e_E_K.) ,3 _.-A 0 rt4--6 -- i)k--6 Reinforcement in Place Foundation/Dampproofing Backfill Approval a cA13 . �; Cs= tN') p cg- 4 Plumbing Under Slab / ,c _ — Plumbing Vent/Vents in Place ` ' �� r Rough Plumbing %1� 1 V-o ci is-V Heating Rough-In Foundation Walls Interior (R- thsulation - Dtc;'- 4,1 Foundation Walls Exterior Floors R- Walls R- (-- i r,.x, ' r- Ceiling R- 1 a.-`� �1�Y� ��'���,t Duct work or piping in C c G- unheated spaces R- •° Proper Vent, Attic Vent ranting is r-AR c z Jack Studs/Headers Bracing/Bridging Joist Hangers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1, 2, 3, hour Penetration Sealed Fire Wall 2, 3, 4 hour Firestopping Z- 13.6VE-C1-Ta GENERAL INSPECTION REPORT Town of Queensbury Dept. of Community Development Date inspection request received: Building& Code Enforcement 742 Is ay Road Queensbury,NY 12804 Arrive.13C)a mp Depa Inspector's Initi NAME: l.l_ J ERRC-€-_ PERMIT# a— L LOCATION: c376 rn 1 yG RAG DATE : c '-7—on TYPE OF STRUCTURE: C n P111 L (>1 RECHECK N/A YES NO COMMENTS Footings/Piers Monolithic Pour Form Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site Foundation/Wallpour Reinforcement in Place Foundation/Dampproo g Backfill Approval Plumbing Under Slab Plumbing Vent/Vents in Pl..- Rough Plumbing Heating Rough-In Insulation Foundation Walls In erior R- Foundation Walls -rior R- Floors R- Walls R- Ceiling / R- Duct work or ping if unheated ..ces R- Proper Vent, Attic Vent Framing H1)k.. G�d� 7� Q-D 0 F Pv Q--LA Jack Studs/Headers 3 Bracing/Bridging — flEM lJ - v.��L Joist Hangers A l� �' 24 M t tl�� 0 V-m Jack Posts/Main Beam ` _ UiGIA Air Infiltration Barrier GO D Fire Separation 1, 2, 3, hour 1"—`J Penetration Sealed Fire Wall 2, 3, 4 hour Firestopping c_fl��np j Dt6C- o -Clamo tom/ TALI_ FIi� -O� GENERAL INSPECTION REPORT ( 518 ) 761-8256 Town of Queensbury Dept.of Community Development Date inspection request received: Building& Code Enforcement 742 t ay Road Queensbury, NY 12804 Arrive 2,0 am/pm Depart'` pnr-- Inspector's Initia NAME: BL14t/-) RF5,iF PERMIT# 4E2 LOCATION: :3—TLo ()1 1C., A Ft�Ll� DAT : -- TYPE OF STRUCTURE: RECHECK • N/A O COMMENTS Footings/Piers Monolithic Pour Form Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. DV3C,L 1A6V Materials for this purpose on site Foundation/Wallpour Reinforcement in Place Foundation/Dampproofing Backfill Approval D C� �+ Plumbing Under Slab �J Plumbing Vent/Vents in Place Rough Plumbing Heating Rough-In Insulation Foundation Walls Interior R- Foundation Walls Exterior R- Floors R- Walls R- Ceiling R- Duct work or piping in unheated spaces R- Proper Vent, Attic Vent Framing Jack Studs/Headers Bracing/Bridging Joist Hangers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1, 2, 3, hour Penetration Sealed Fire Wall 2, 3,4 hour Firestopping 'srennon resign t►s :+eies 1 West Street• Green Island• NY,■ 12183 • Phone • 518-272-8281 Architect's Field Report OWNER [X] ARCHITECT [XI AIA Document G711 - CONSULTANT [ Electronic Format FIELD [ THIS DOCUMENT HAS IMPORTANT LEGAL CONSEQUENCES; CONSULTATION WITH AN ATTORNEY IS ENCOURAGED WITH RESPECT TO ITS COMPLETION OR MODIFICATION. AUTHENTICATION OF THIS ELECTRONICALLY DRAFTED AIA DOCUMENT MAY BE MADE BY USING AIA DOCUMENT D401. PROJECT: BILL'S BEVERAGE CENTER FIELD REPORT NO: 04 CONTRACT:ADDRESS__ 376 Dix Avenue. Queensbury, ARCHITECT'S PROJECT NO: ARC 567 NY ----DATE: 12=20-99 - -- TIME 7:00-am - WEATHER:-Overcast TEMP.RANGE: 2O- - EST.%OF COMPLETION: CONFORMANCE WITH SCHEDULE(+,-): WORK IN PROGRESS: PRESENT AT SITE: Steel Erection Crew OBSERVATIONS: ITEMS TO VERIFY : INFORMATION OR ACTION REQUIRED: ATTACHMENTS: REPORT BY: Roger King-Hall, Architect Insert_ A: The septic system has been completed, backfilled and the area oraded, ready for seeding. The steel building has been delivered�Q the site and.11 the framinqaDhe structural elements have jgert erected, columns. beams and purlins. Cable bracing is also in place. The metal walls and insulation on the south and west walls have en erected. The chain -link- l`ence-Without'the cafes—lies-been—installed -- -- - -- All the base coat asphalt la laid and the parking designations painted. The landscaping earth berms have been gradedQn_the north . side.f_the site. Insert B:cc: gill Petrosino-Owner/rlohn O`Brien-Building Inspector,,/ RobertBecker I File AIA DOCUMENT G711 - ARCHITECT'S FIELD REPORT - OCTOBER 1972 EDITION - AIA - COPYRIGHT 1972• THE AMERICAN INSTITUTE OF ARCHITECTS,1735 NEW YORK AVENUE,N.W.,WASHINGTON,D.C.,20006-5292. WARNING; Unlicensed photocopying violates U.S.copyright laws and is subject to legal prosecution.This document was electronically produced with permission of the AIA and can be reproduced without violation until the date of expiration as noted below. Electronic Format G711-1972 User Document:ARC— 12/21/1999.AIA License Number 107629,which expires on 3/6/2000--Page#1 lJ 301 GENERAL INSPECTION REPORT ( 518 ) 761-8256 Town of Queensbury Dept.of Community Development Date inspection request received: Building& Code Enforcement 742 Bay Road Queensbury,NY 12804 Arrive/O 9 am/pm Depart am/pm Inspector's Initial's-/y NAME: Q k I t 'S v PERMIT# E-15 LOCATION: 3—) (gyp j- DATE : — — TYPE OF STRUCTURE:Pi-. 2,1� ' Q t - I C RECHECK N/A YES NO COMMENTS Footings/Piers I Monolithic Pour Fonu Reinforcement in Place The contractoris responsi le for providing protection from-.reeling for 48 hours following the lacemcnt of the concrete. Materials for this purpose on itc Foundation/Wallpour Reinforcement in Place Foun tion/Dampproofing fill Approvala �'GrF, (t Plumbing Under Slab Plumbing VenUVents in Plac Rough Plumbing Heating Rough-In Insulation Foundation Walls Interior R • - Foundation Walls Exterior R- Floors R- Walls R- Ceiling R- _ Duct work or piping in unheated spaces R- Proper Vent, Attic Vent _ Framing Jack Studs/Headers Bracing/Bridging Joist Hangers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation I, 2, 3, hour Penetration Sealed Fire Wall 2, 3,4 hour Firestopping GENERAL INSPECTION REPORT ( 518 ) 761-8256 Town of Queensbury Dept.of Community Development Date inspection request received: Building&Code Enforcement 742 ay Road Queensbury,NY 12804 Arrive 1Z,?(.0an pm Depart O6 Inspector's Inyte NAME: 3<[ V, B ERA PERMIT# �--[ LOCATION: I A DATE : TYPE OF STRUCTURE: C-O RECHECK N/A YES NO COMMENTS Footings/Piers Monolithic Pour Form Reinforcement in Place The contractor is respon.ible for \ providing protection fro freezing for 48 hours following t c placem nt of the concrete. - Materials for this purpose o i site Foundation/Wal pour Reinforcement in Place Foundation/Da mpproofi ng .Backfill Approval Plumbing Under Slab Plumbing Vent/Vents in Place Rough Plumbing Heating Rough-In Insulation Foundation Walls Interior R- Foundation Walls Exterior R- Floors R- Walls R- Ceiling R- Duct work or piping in unheated spaces R- Proper Vent, Attic Vent Framing 6SR.`t iIiQRI EFL \(160P1L I�ECij(0►J [��t� Jack Studs/Headers Bracing/Bridging (�16 Joist Hangers 2_1 N) —W) J FLACE PR.111)E_D C rE Jack Posts/Main Beam C��--I�M \ CMFPA- —PID p OOZ_ Air Infiltration Bather I� Fire Separation 1, 2, 3, hour '(1 M 1 i OJ1 Penetration Sealed Fire Wall 2, 3,4 hour Firestopping Ink TOWN OF QUEENSBURY /0/4J BUILDING & CODE ENFORCEMENT 742 Bay Road Queensbury NY 12804 (518) 761-8256 SEPTIC DISPOSAL SYSTEM INSPECTION Name 1 l 1=1S (6-9-,V, QN9 Location 3 i (0 ! X .A).SLAkk Date 11 —D,1a Permit #- n—( - SOIL TYP .:PP lar+ y-�; a Results of Per.colia1 i on Test- 1 (if applicable)/Rate-Minute/I'nch TYPE OF SYSTEM: / ABSORPTION FIELD: Total Lejfgth 1--izn Length of each trench P, 64/ .s-r Depth of trenches tl—V—,g7-,t-c,'� Size of stone /s?! SEEPAGE PITS: Number- I Size - ft. x / ft. Stone size PIPING: ''., di' Size Type Bldg. to Tank iti\ QJ. a ��Tank to Dist. Box '�_- Y Dist. Box to Fi el c/Pit y ,DE3'L Openings Sealed?., Yes No Pa ial PE LOCATION/SEPARATIONS: G�05 ci Foundation to Tank feet Foundation tobsorption _ Separation of Pits eet Conforms as per Plot Plan LOCATION OF SYSTEM ON PROPERT : (circle on ) Front - R ar - Left Si ight Side , Middle Front - • d e� Rear COMMENTS: • SYSTEM USE APPROVED: NO Arrived: °. Depart --.._ uilding s ctor TOWN OF QUEENSBURY 7f� BUILDING & CODE ENFORCEMENT 742 Bay Road Queensbury NY 12804 (518) 761-8256 �M SEPTIC DISPOSAL SYSTEM INSPECTION Name S - Location 3 7(.4 �i Date 11—` -99 `7'Permit # 9-6 SOIL TYPE: Sand-Loam-Clay- Results of Perco ati.n Test- (if applicable) Rate-t4nute/Inch TYPE OF SYSTEM: ABSORPTION FIELD Total Length Length of each t ench Depth oft trenche Size of s, one SEEPAGE PITS: Nu ber- Size - ft. x ft. Stone size PIPING: Size type Bldg. to Tank ei" Tank to Dist. Box y%' •6 Dist. Box to Field 'i Openings Sealed? 40 No Partial LOCATION/SEPARATION`. Foundation to Tank Y,!r" feet . Foundation to Absorption feet Separation of Pits eet Conforms as per Plot Plan No LOCATION OF SYSTEM ON PROPERT : (circle one) Front - Rear - Left Side - Right Side Middle Front - Middle Rear COMMENTS: /J D ov4 4,4%, SYSTEM USE APPROVED: YES 0 Arrived: c,3O Departed: Building Inspector GENERAL INSPECTION REPORT ( 518 ) 761-8256 Town of Queensbury • Dept.of Community Development Date inspection request received: Building&Code Enforcement 742 ::ay Road Queensbury,NY 12804 Arrive am/pm Depart Inspector's lnitial � NAME: 4 ESE_ PERMIT# LOCATION: DATE : — TYPE OF STRUCTURE: '� � , t. RECHECK N/A YES NO COMMENTS Footings/Piers I Monolithic Pour Form Reinforcement in Place The contractor is responsib a for providing protection from reeving for 48 hours following th•placeme t of the concrete. Materials for this purpose o,i site Foundation/Wallpour VA. 1_ pi L- Reinforcement in Place ft Foundation/Dampproofing Back fill Appro Plumbing Under Slab Plumbing Vent/Vents in PH e Rough Plumbing Heating Rough-In Insulation DOTE - PRO 6 EC Foundation Walls Interio R- Foundation Walls Exteri.i R- ‘Ek.-3) Va btEr Floors k.T20_1 1 i sCri6 Walls Ceiling R- Duct work or piping in unheated spaces R- Proper Vent, Attic Vent Framing Jack Studs/Headers Bracing/Bridging Joist Hangers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1, 2, 3, hour Penetration Sealed Fire Wall 2, 3, 4 hour Firestopping GENERAL INSPECTION REPORT ( 518 ) 761-8256 Town of Qucensbury Dept.of Community Development Date inspection request received: Building& Code Enforcement 742 Bay Road Queensbury,NY 12804 Arrive yi2`jam/pm Depart am/pm �f, Inspector's Iniittiaals NAME: !7/11 ��'e y• ,4 PERMIT# 2 ✓ LOCATION: i'D6e 4,e DATE : //Mr TYPE OF STRUCTURE: RECHECK N/A YES NO COMMENTS Footings/Piers I Monolithic Pour Form Reinforcement in Place The contractor is responsible-for providing protection from frecrin for 48 hours following the plicpnient of the concrete. Materials for this purpose on si.c_ Foundalion/Wallpour Reinforcement in Place Foundation/Dampproofing Backfill Approval • Plumbing Under Slab Plumbing Vent/Vents in Place • Rough Plumbing Heating Rough-In Insulation fh.v Foundation Walls Interior R- 5 • Foundation Walls Exterior R- Floors R- Walls R- Ceiling R- Duct work or piping in unheated spaces R- Proper Vent, Attic Vent Framing_ _ Jack Studs/Headers Bracing/Bridging Joist Hangers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1, 2, 3, hour Penetration Sealed Fire Wall 2, 3,4 hour Firestopping tee GENERAL INSPECTION REPORT ( 518 ) 761-8256 Town of Queensbury Dept.of Community Development Date inspection request received: Building& Code Enforcement 742 Bay Road Queensbury,NY 12804 Arrive .Piidam/pm Depart am/pm Inspector's Initials p I nn' NAME: S Nia PERMIT# `` �c'L LOCATION: nDATE : r 1—/®—� TYPE OF STRUCTURE: Jam/ RECHECK N/A YES NO COMMENTS Footings/Piers J I Monolithic Pour Form Reinforcement in Place The contractor is res• '+Ic for providing protection rom freezing for 48 hours followin_ the pla-cmcnt of the concrete. Materials for this purpo a on si c Foundation/Wallpour Reinforcement it Plac _ Foundation/Dampproof i n 2 Backfill Approval Plumbing Under Slab ►� Plum 'tg Vent/Vents in P ace ugh Plumbing Heating Rough-In Insulation Foundation Walls Inters r R- Foundation Walls Exte or R- Floors R- Walls - Ceiling Duct work or piping in unheated spaces R- Proper Vent, Attic Vent_ _ Framing — —_-- Jack Studs/Headers Bracing/Bridging Joist Hangers Jack Posts/Main Beam_ Air Infiltration Barrier Fire Separation I, 2, 3, hour Penetration Scaled Fire Wall 2, 3,4 hour Firestopping /07&/),_ GENERAL INSPECTION REPORT ( 518 ) 761-8256 Town of Queensbury Dept.of Community Development Date inspection request received: �` � Building&Code Enforcement 742 Bay Road Queensbury, NV 12804 Arrive C2 y ; ipm 4. part Inspector's Initi NAME: !i;;: . TTYPE OF STRUCTURE: � /� o j RECHECK 4)" N/A COMMENTS Footin i >/I r— Monolithic Pour Form I D ��°�avt 2IZ ' e Reinforcement in Place The contractor is responsible for providing protection from reeving for 48 hours following t c placement of the concrete. Materials for this purpos on site Foundation/Wallpour A-LA\�, Reinforcement in Place Foundation/Dampproo i g, D Backfill Approval` '', � e,F�if rieTipL40TA Plumbing Under Sta. Plumbing Vent/Ven . in Place Rough Plumbing Heating Rough-In Insulation Foundation Walls Interior R- t-3 T=P � E--U'ENW1b13 Foundation ` alls Exterior R- Floors R- Walls R- Ceiling R- Duct work or piping in � J �S Or� unheated spaces R- Proper Vent, Attic Vent Framing Jack Studs/Headers Bracing/Bridging Joist Hangers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation 1, 2, 3, hour Penetration Sealed Fire Wall 2, 3,4 hour Firestopping ,- _,._ \,,, ,• -.3._crbo . . ) a/uory\ • -,-,----,---..,:„,,,„.,,,,,,,..,,.,:5„, _.,....,4„„„,...„......,:.„,„,5„.„, GENERAL INSPECTION REPORT ( 518 ) 761-8256 Town of Qucensbury Dept.of Community Development Date inspection request received: Building& Code Enforcement 742 Bay "oad Qucensbury, NY I2804 Arrive 12:61/pm .! part • m . Inspector's Initia r NAME: PERMIT# - LOCATION: -J �� �( �l DATE : / f - ,�-9 TYPE OF STRUCTURE: (\..).2 ,J GC )1 \ C- RECHECK N/A YES NO COMMENTS Footings/Piers I I Monojith. Pour Form rcc ent in-' The contractor is responsible for • providing protection from fr nng for 48 hours following the p1 cement -- of the concrete. • Materials for this purjosc on si c Foundation/Wallpour '\, ! C Reinforcement in Place__ p ` - ei E �T i '"'�4I Foundation/Dampproofing � �-t- /j J'1 L`� 6F- 6uk. T ,.....ALL__, Backfill Approval v Plumbing Under Slab Plumbing Vent/Vents in Place Rough Plumbing Heating Rough-In Insulation Foundation Walls Interior R- Foundation Walls Extc or R- Floors R- Walls R- Ceiling R- Duct work or piping in unheated spaces R- _ Proper Vent, Attic Vent Framing_ Jack Studs/Headers Bracing/Bridging Joist Hangers . Jack Posts/Main Bcam _ Air Infiltration Barrier Fire Separation 1, 2, 3, hour Penetration Sealed Fire Wall 2, 3,4 hour Firestopping GENERAL INSPECTION REPORT ( 518 ) 761-8256 Town of Queensbury Dept.of Community Development Date inspection request received: Building& Code Enforcement 742 Bay Road Queensbury, NY 12804 Arrive` t.\-t,)am(pm2.- Depart o a m j pector's Initial NAME: 2=5.:‘&\)(P`CCX ♦ PERMIT# c LOCATION: .'1 '1 ( mot.• DATE : :k_CI) TYPE OF STRUCTURE: 1\)Q3, a Cl \ • RECHECK N/A YES NO COMMENTS Footings/Piers I I Monoli hic Pour Form It • orccment in Place The contractor is respons. a for providing protection fro fre ..ing for 48 hours following is placement ' of the concrete. atcrials fo his purpose on sit oundation/Wa .:_ f,0 v4-0 0 D l I e1 C.E_ �I t l Reinforcement in Place V' i���L �`t ' Foundation/Dampproofing 1•'� 'j Backfill Approval Plumbing Under Slab Plumbing Vent/Vents in Plact Rough Plumbing Heating Rough-In Insulation _ Foundation Walls Interior ' Foundation Walls Exterior ' Floors R- Walls R- Ceiling R- Duct work or piping in unheated spaces R- Proper Vent, Attic Vent_ __ Framing_ Jack Studs/Headers__ Bracing/Bridging Joist Hangers . Jack Posts/Main Beam Air Infiltration Barrier Fire Separation I,2, 3, hour Penetration Scaled Fire Wall 2, 3, 4 hour Firestopping GENERAL INSPECTION REPORT ( 518 ) 761-8256 Town of Queensbury Dept.of Community Development Date inspection request received: Building& Code Enforcement • 742 ::.ay Road • Queensbury,NY 12804 Arrive `1-1 0I.m Depart _ � 1� .1119�. Inspector's Initi �� NAME: Pj1U EC�,!j `� �C�� •PERMIT# ��,is-- LOCATION:SL �J'��l) DATE : r a — TYPE OF STRUCTURE: (iC .•G I- —1 . RECHECK N/A YE. NO COMMENTS ootings/Piers Slit Monolithic Pour Form 1 Reinforcement in Place 1 The contractor is respo isible fbr providing protection from freeing for 48 hours following hc pla cement of the concrete. Materials for this purpose on si Foundation/Wallpour Reinforcement in'P ace F Foundation/Dampproo in,; . Backfill Approval Plumbing Under Slab Plumbing Vent/Vents in Rough Plumbing Heating Rough-In Insulation Foundation Walls Int. for R • - Foundation Walls Ex, rior R • - Floors R- Walls R- Ceiling R- Duct work or piping in unheated spaces R- Proper Vent, Attic Vent Framing Jack Studs/Headers Bracing/Bridging Joist Hangers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation I, 2, 3, hour Penetration Sealed Fire Wall 2, 3, 4 hour Firestopping I GENERAL INSPECTION REPORT ( 518 ) 761-8256 Town of Queensbury Dept.of Community Development Date inspection request received: Building& Code Enforcement 742 Bay Road Queensbury, NY 12804 Arrive\ 4ai :►p Inspector's • Ii.rAY'IF�1 NAME: Qjt\t...\_Is re( — PERMIT#`may - LOCATION: -3-7( 0 DATE : — TYPE OF STRUCTURE: RECHECK N/A' YES NO COMMENTS Footings/Piers Monolithic Pour Fonn Reinforcement in Place The contractor is responsiole fur providing protection fro free'.ing for 48 hours following tI c plaIcmcnt of the concrete. ate is forthis purpose on s' c undation/Wallpour Edo? \ '_P6T- *LL Reinforcement in Plac V Foundation/Damppro ing Backfill Approval Plumbing Under Sla Plumbing Vent/Vent in Place _ Rough Plumbing Heating Rough-In Insulation Foundation Walls nterior R- Foundation Walls xtcrior R- Floors R- Walls R- Ceiling R- Duct work or piping in unheated spaces R- _ Proper Vent, Attic Vent_ _ FramingJack Studs/Headers Bracing/Bridging Joist Hangers Jack Posts/Main Beam • Air Infiltration Barrier Fire Separation 1,2, 3, hour _ Penetration Sealed Fire Wall 2, 3,4 hour Firestopping _ It °665 ILM 7 \ 0bVIA �. \ ci c GENERAL INSPECTION REPORT ( 518 ) 761-8256 Town of Queensbury Dept. of Community Development Date inspection request received: Building& Code Enforcement 742 Bay Road Quecnsbury,NY 12804 Arrive V201 air t epa �� a nspector's Initi NAME: cb\\\ af PERMIT# LOCATION: DATE : TYPE OF STRU TU \ . }' RECHEC • N/A YVNO COMMENTS F otings/Piers � I onolithic Pour Form Reinforcement in Place The contractor is responsible f r `� • �/ providing protection from freeing I V �11`�n for 48 hours following the pla,,ement N of the concrete. Materials for this purpos on sit, Foundation/Wallpour Reinforcement in Place Foundation/Dampproofing Backfill Approval I Plumbing Under Slab • Plumbing Vent/Vents in Pla c Rough Plumbing Heating Rough-In Insulation Foundation Walls Interior R- Foundation Walls Ext rior R- Floors R- Walls R- Ceiling R- Duct work or piping in unheated spaces R- Proper Vent, Attic Vent Framing Jack Studs/Headers Bracing/Bridging Joist Hangers Jack Posts/Main Beam Air Infiltration Barrier Fire Separation I, 2, 3, hour Penetration Sealed Fire Wall 2, 3, 4 hour Firestopping