RC-0645-2021 Office Use Only ADDITION/ALTERATION PERMIT Permit#: 9-C-- O 645-- 202,1 APPLICATION Permit Fee:$ Town of Queensbury X� 742 Bay Road,Queensbury,NY 12804 Invoice#: 44t> P:518-761-8256 www.gueensbury.net Flood Zone? b N Reviewed By: Project Location: 93 Fitzgerald Road Tax Map ID#: 289.14-1-24 Subdivision Name: D PROJECT INFORMATION: A16 3 0 202' TOWN OF QUCCIVSB BUILDING TYPE: X Residential Commercial, Proposed Use: & �ODURY CS X Single-Family _Two-Family _Multi-Family(#of units ) _Townhouse _Business Office _Retail _Industrial/Warehouse _Garage (#of cars_) Other (describe ) ADDITION SQUARE FOOTAGE: ALTERATION SQUARE FOOTAGE: 1st floor: 319 SF 1st floor: 781 SF 2nd floor: 753 SF 2nd floor: 78 SF 3rd floor: 3rd floor: Basement(habitable space): Basement (habitable space): Total sq ft:1072 SF Total sq ft: 859 SF Scope of work to be done: Entire building first floor to be renovated, new mudroom entry to be constructed, single story roof portion of building to be removed and a second floor constructed over existing first floor to match existing second floor in height. New covered porch to be added above existing open deck on.lake side of building. New septic system to be installed per the septic variance granted by the Queensbury Board of Health. Addition/Alteration Application Revised January 2021 JPT CONTACT INFORMATION: PLEASE PRINT LEGIBLY OR TYPE, PLEASE INCLUDE AN EMAIL • Applicant: Name(s): Ethan P. Hall-ArchitectWgent for the Applicant Mailing Address, C/S/Z: 134 Dix Ave, Glens Falls NY 12801 Cell Phone: 518 )260-2888 Land Line: 518 )741-0268 Email: ephall@nycap.rr.com • Primary Owner(s): Name(s): Charles Carder-Caren Tucker Mailing Address, C/S/Z: 12 Henry Austin Drive, Wilton CT 06895 Cell Phone: 203 )912-9047 Land Line: Email: cctucker@optonline.net ❑ Check if all work will be performed by property owner only • Contractor(s): (List all additional contractors on the back of this form) Contact Name(s): Hilltop Construction-Dan Washburn Contractor Trade. General Contractor-All work to be performed by Hilltop Construction Mailing Address, C/S/Z: 51 Cowley Road, Hudson Falls NY 12839 Cell Phone: ( 518 )260-7363 Land Line: 518 )747-0308 Email: danw@hilltopconstructionco.com **Workers' Comp documentation must be submitted with this application** • Architect(s)/Eneineer(s): Business Name: Rucinski Hall'Architecture Contact Name(s). Ethan P. Hall Mailing Address, C/S/Z: 134 Dix Ave, Glens Falls NY 12801 Cell Phone: 518 )260-2888 Land Line: 518 1741-0268 Email: ephall@nycap.rr.com Contact Person for Compliance in regards to this project: Ethan P. Hall Cell Phone: 5( 18 )260-2888 Land Line: 518 )741-0268 Email: ephalig-Mycap.mcom Addition/Alteration Application Revised January 2021 SEPTIC DISPOSAL PERMIT Office Use only APPLICATION Permit#: gal ftofQucens Permit Fee:$ Invoice#: 742 Bay Road,Queensbury,NY 12804 P:518-761-8256 www.gueensbury.net Flood Zone? oy N Reviewed By: Project Location: 93 Fitzgerald Road AUG 3 0 2021 Tax Map #: 289.14-1-24 TOWN OF QUEENSBURY BUILDING&CODES RESIDENCE INFORMATION: Year Built Gallons #of bedrooms: X gallons per =total daily flow per day bedroom Garbage Grinder Yes No 1980 or older 150 Installed? (choose one) X - 1981-1991 130 Spa or Hot Tub Yes No 1992-Present 1110 4 j110 j 440 Installed? (choose one) X PARCEL INFORMATION: Topography x Flat Rolling x Steep Slope 90 % Slope Soil Nature Sand Loam Clay Other, explain: Gravel with cobbles Groundwater At what depth?not encountered at 65" Bedrock/Impervious material At what depth?not encountered at 65" Domestic Water Supply Municipal Well Lake Glen Lake (if well or lake, water supply from any septic system absorption is ft.) 80'- per variance granted fro Queensbury BOH Percolation Test Rate: 1:30 per minute per inch (test to be completed by a licensed engineer/architect) PROPOSED SYSTEM INFORMATION: Tank size gallons (min. size 1,000 gallons, add 250 gallons for each garbage cylinder or spa/hot tub Norweco model 960 size to accomodate a 4 bedroom home System Absorption field w/#2 stone Total length ft.; Each Trench ft. Seepage Pit w/#3 stone How many: ; Size: Alternative System Bed or other type: Holding Tank System Total required capacity? ; tank size ; # of tanks Disposal system is a bottomless sand filter located at the back of the property in accordance with the variance issued by the Queensbury BOH. Septic Application Revised January 2021 FUEL BURNING APPLIANCE & office use only CHIMNEY APPLICATION Permit#:P� "/�� S • Zps I Permit Fee:$ 35 Town of 0_wensbur}• 742 Bay Road,Queensbury,NY 12804 Invoice#: ZD 1 P:518-761-8256 www.ciueensbury.net �OST• 1�S�tA1�0.}�p,1� **ONE APPLICATION PER APPLIANCE** Project Location: "I "+Z [ k(, Tax Map ID#: 9 1 1 M " I " Dl ` Room of Install: Ij VI hQ IoOkA Planned Install Date: FUEL BURNING APPLIANCE INFORMATION: D E C TYPE OF DEVICE: JUN 0-8 2022 Stove �Fireplace Insert X Firepl ce TOW"'OF O�L=ENS T Fuel Fired Equipment(Garage Only: 18"clearance per IMC 304.3 JUILDII�C CODERY J Fireplace,factory built** (**Manufacturer's name: Model#: ) SOURCE OF HEAT: Wood _Coal =Pellet Gas CHIMNEY INFORMATION: _Masonry(require plans to be submitted): block _brick _stone X Flue: tile steel 14;7�size, in inches _Material*: .X double-wall —triple-wall_insulated (*Manufacturer's name: I l Model#: r yO ) Fuel Burning Appliance&Chimney Application Revised December2020 CONTACT INFORMATION: PLEASE PRINT LEGIBLY OR TYPE, PLEASE INCLUDE AN EMAIL e Applicant: Name(s). Mailing Address, C/S/Z: r 1 ,I'1 __ Cell Phone: Land Line: Email: 'ii i wi ( `�3� ��, c hb ✓ c;� • Primary Owner(s): 1-_ Name(s): Carien `FGiC cr Mailing Address, C/S/Z: i t ; C Cell Phone: (A_J 4 ` Land Line: _{ ) Email:- LC. L r i a h ❑ Check if all work will be performed by property owner only Installer Builder: Workers'Comp documentation must be submitted with this application ContactName(s): An ()_)a5 hi_wn Contractor Trade: i COn-h-orintr Mailing Address, C/S/Z: - 5o Cell Phone:_( �)N� ) Cj q Land Line: _( . l E- ) Email:AId LU Contact Person for any questions regarding this project: Cell Phone:�_) Land Line: Email: ADDITIONAL INFORMATION: 1. Two(2)inspections are required. A rough-in inspection,prior to installation and a final inspection, after installation. 2. Manufacturer's installation manual must be available at the time of inspection. 3. Masonry fireplaces&chimneys require plans to be submitted. 4. Twenty-four(24)hour notification is required for inspections. 5. Workers'Comp insurance information is required with this application. Declaration:Construction/installation must conform to NYS Fire Prevention &Building Code and/or manufacturer requirements. The applicant or owner agrees to comply with all applicable laws,ordinances, regulations and all conditions that are part of these requirements and also will allow the inspector to enter the premises to perform the required inspections. I have read and agree tjon the above: PRINT NAME: SIGNATURE: b( Ly P DATE: Fuel Burning Appliance&Chlmney Application Revised December 2020 CLTOWN OF OUEENSBURY 742 Bay Road, Queensbury, NY. 12804-5902 Septic System Checklist Plan to scale ' Received Deep hole perc test results from engineer/Architect if applicable (Town Approved Engineers and Architects;June 30 to April 15 Town Engineer for unapproved Engineers and Architects) (r-'All wells on property and adjacent properties shown Ir, Water line shown Municipal or well 10'separation to any part of system Setback to property lines show 10'or more for any part of system ���/> `m varpo l—&- I?�Septic tank and pump stations 10'from foundation 50'from any well/lake/wetland 10'from any waterline AA-Septic tank to foundation crawl space/slab on grade,grade in crawl space must be above top of septic tank for 0',Separation required (field verification required) J Septic tank sized for number of bedrooms and add 250 gals for Jacuzzi tubs/garbage grinder each t Leech Field 20'from foundation 100'from any well 10'from waterline 7 ►-�� ,f,A, Seepage pit 150'from well 50'from septic tank Seepage Pits 3-times diameter apart y Septic tank and pump stations over 30 gallons 50'from watercourse or wetland � ��► /� i'� P lec'p' distance from bottom of trench or system 24"to bedrock or mottling 36" within 1000' of Lake George el -'Leech field 100'from watercourse or wetland Toe of mound or bottom of retaining wall 10'from property line 100' from well 20'from Foundation 7e,,_LProvide Engineer/Architect stamp for bed or design systems "ADepartment of Health Approval for all mobile home park new systems Flood Plain requirements lU 2' above established flood elevation to bottom of system ts.167All tanks anchored or 2' above flood elevation Revised 4/15/2021 A-2,�24 C�( Generated by REScheck-Web Software J Compliance Certificate Project Carder-Tucker Addition Energy Code: 2018 IECC Location: Glens Falls,.New York construction Type: Single-family Project Type: Addition Climate Zone: 6 (7635 HDD) Permit Date: Permit Number: Construction Site: Owner/Agent: Designer/Contractor 93 Fitzgerald Road, Charles Carder Caren Tucker Ethan P.Hall Queensbury,NY 12804 93 Fitzgerald Road Rucinski Hall Architec ure Queensbury, NY 12804 134 Dix Ave Glens Falls, NY 12801 518-741-0268 ephall@nycap.rr:com • • e UA trade-off Compliance: 0.0%Better Than Code .Maximum UA: 95 Your UA: 95 The%Better or Worse Than Code index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Slab-on-grade tradeoffs are no longer considered in the UA or performance compliance path in REScheck. Eai h slab-on-grade assembly In the specified climate zone must meet the minimum energy code insulation R-value and depth re uirements: Envelope Assemblies Gross Area Cavity Cont. Prop. ReqJ1 Prop. Req. Perimeter I! Ceiling 1:Cathedral Ceiling 859, 49.0 0.0 0.022 0.0 M 19 .22 Wall 1:Wood.Frame,16"o.c. 926 28.0, 0.0 0.050 0.015 41 37 Window 1:Wood Frame:Double Pane with Low-E 100 0.290 0.300 29 30 Floor 1-All-Wood joistrrruss:Over Outside Air 192 30.0 0.0 0.033 0.033 6 6 Compliance Statement: The proposed building design described here is consistent with the building plans,s ecifications, and other calculations submitted with the permit application.The proposed building has bee designed to:meet the 20 8 IECC requirements in REScheck Version: REScheck-Web and to comply with the mandato uirem. Ji i t ` EScheck In pection Checklist. Ethan P.Hall-Architect ` ' ��"" 4 ��• ;" Name-Title Si nat 7 f 3" "�';.*.`>` Date -�-asr r•� Project Title: Carder-Tucker Addition Report date: 02/01/22 Data filename: Page 1 of 9 Generated by REScheek-Web Software Compliance Certificate Project Carder-Tucker Addition Energy Code: 2018 IECC Location: Glens Falls, New York Construction Type: Single-family Project Type: Addition Climate Zone: 6 (763S.HDD) Permit Date: Permit Number: Construction Site: Owner/Agent: Designer/Contractor 93 Fitzgerald Road, Charles Carder Caren Tucker Ethan P. Hall Queensbury, NY 12804 93 Fitzgerald Road Rucinski Hall Architec ure. Queensbury, IVY 12804 134 Dix Ave Glens Falls, NY 12801 518-741-0268 ephall@nycap.rr.com • • -: 'Passes using ILIA trade-off Compliance:0.0%Better Than Code Maximum UA: 95 Your UA: 95 The.%Better or Worse Than Code.lndex reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to,a minimum-code home. Slab-on-grade tradeoffs are no longer considered in the UA or performance compliance path in REScheek. Ea h slab-on-grade assembly In the specified climate zone must meet-the minimum energy code insulation R-value and depth re juirements. Envelope Assemblies Prop-Assembly Gross Area Cavity Cont. ' Req Prop. Perimeter I .Ceiling 1:Cathedral Ceiling 859 49.0 0.0 0.022 0.0 1 26 19 22 Wall 1:Wood Frame, 16"o.c. 926 28.0 0.0 0.050 0.045 41 37 Window 1:Wood Frame:Double Pane with Low-E 100 0.290 0.3 0 29 30 Floor 1:All-Wood joistlrruss:Over Outside Air 192 30.0 0.0 0.033 0.0 3 6 6 Compliance Statement. The proposed building design described here is consistent with the building plans,specifications,and other calculations submitted with the permit application.The proposed building has bee designed.to..meet the 203 8 IECC requirements in REScheek Version:REScheek Web and to comply with the mandato uirern Ji I t EScheck Inspection Checklist. Ethan P.Hall-ArchitectAM 22:1120 ��.. Name-Title Si nat ;f;�,y' .�.,,I 'a ;: _ ;°� Date 1` x.m7 Project Title: Carder-Tucker Addition Report date: 02/01/22 Data filename: Page 1 of 9 Generated by REScheck-Web Software Compliance Certificate Project Carder-Tucker Addition 2 Energy Code: Glen IECC 89.14-1-24 RC-0645-2021 Location: Glens Falls, New York Carder, Charles & Caren Tucker Construction Type: Single-family 93 Fitzgerald Rd Project Type: Addition Residential Add 1072 s.f., Alt 859 s.f. Climate Zone: 6 (7635 HDD) Permit Date: Permit Number: Construction Site: Owner/Agent: Designer/Contractor: 93 Fitzgerald Road Charles Carder Caren Tucker Ethan P.Hall Queensbury, NY 12804 93 Fitzgerald Road Rucinski Hall Architecture Queensbury, NY 12804 134 Dix Ave Glens Falls, NY 12801 518-741-0268 ephall@nycap.rr.com �Compliance: Passes using UA trade-off Compliance: 3.2%Better Than Code Maximum UA: 95 Your UA: 92 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-REOV I EWE D FOR It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. ENERGY CODE COMPLIANCE - Envelope Assemblies Gross Area Cavity Cont. Prop. Req. Prop. Req. Assembly or R-Value R-Value 0-Factor U-Factor UA UA Perimeter Ceiling 1:Cathedral Ceiling 859 49.0 0.0 0.022 0.026 19 22 Wall 1:Wood Frame, 16"o.c. 926 21.0 3.6 0.046 0.045 38 37 Window 1:Wood Frame:Double Pane with Low-E 100 0.290 0.300 29 30 Floor 1:All-Wood joist/Truss:Over Outside Air 192 30.0 0.0 0.033 0.033 6 6 Compliance Statement, The proposed building design described here is consistent with the building plans,specifications,and other calculations submitted with the permit application.The proposed building has been designed to meet the 2018 IECC requirements in REScheck Version : REScheck-Web and to comply with the mandatory g menu;, ed ' t e check Inspection Checklist. Ethan P. Hall-Architect a� Name-Title Signatq (� `�c;°; ?. Date �•�``' � Sri��;.����;�z �` , '� � c , 4 [AUG3 0 ^ 0!1 �TOWN OFOUCNSBURy BUILD &CODES Fr �.ILE ��� Project Title: Carder-Tucker Addition Report date: 08/02/21 Data filename: Page 1 of 9 REScheck Software Version : REScheck-Web Inspection Checklist Energy Code: 2018 IECC Requirements: 100.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section Plans Verified Field Verified # Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions & Req.ID 103.1, ;Construction drawings and ❑Complies ;Requirement will be met. 103.2 documentation demonstrate t❑Does Not [PRl]1 :energy code compliance for the Location on plans/spec:A- (g} ;building envelope.Thermal []Not Observable I1 lenvelope represented on ❑Not Applicable ;construction documents. 103.1, ;Construction drawings and ;❑Complies ;Requirement will be met. 103.2, documentation demonstrate J❑Does Not 403.7 :,energy code compliance for f i❑Not Observable 'Location on plans/spec:A- [PR3]1 lighting and mechanical systems. i ;1 Systems serving multiple ;❑Not Applicable ;dwelling units must demonstrate jf compliance with the IECC Commercial Provisions. I 302.1, ;Heating and cooling equipment is: Heating: Heating: ;❑Complies :Requirement will be met. 403.7 sized per ACCA Manual S based Btu/hr Btu/hr ;❑Does Not [PR2]2 on loads calculated per ACCA Cooling: Cooling: ;Location on plans/spec:A- p Manual J or other methods ❑Not Observable 1 J j approved by the code official. ; Btu/ r Btu/ r ;❑Not Applicable ; I Additional Comments/Assumptions: 11 High Impact(Tier 1) 12 1 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Carder-Tucker Addition Report date: 08/02/21 Data filename: Page 2 of 9 Section # Foundation Inspection Complies? Comments/Assumptions & Req.ID 303.2.1 ;A protective covering is installed to ;❑Complies :Exception: Requirement is not applicable. [F011]z 1 protect exposed exterior insulation :❑Does Not !and extends a minimum of 6 in.below ;grade. :❑Not Observable: ❑Not Applicable j 403.9 }Snow-and ice-melting system controls;❑Complies ;Exception: Requirement is not applicable. [FO12]2 installed. UDoes Not e' ;❑Not Observable; i :El Not Applicable Additional Comments/Assumptions: 1 I High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Carder-Tucker Addition Report date: 08/02/21 Data filename: Page 3 of 9 Section Plans Verified Field Verified # Framing/Rough-In Inspection Value Value .Complies? Comments/Assumptions & Req.ID 402.1.1, :Glazing U-factor(area-weighted ; U- ; U- ;❑Complies ;See the Envelope Assemblies 402.3.1, average). :❑Does Not table for values. 402.3.3, 1 402.5 tNot Observable ; [FR2]1 ; ; ;❑Not Applicable 303.1.3 1 U-factors of fenestration products 1❑Complies ;Requirement will be met. [FR4]1 :are determined in accordance 1❑Does Not �� )with the NFRC test procedure or { ;❑Not Observable Location on plans/spec:A- taken from the default table. j ;1 (((( ;❑Not Applicable ' 402.4.1.1 ;Air barrier and thermal barrier ![]Complies ;Requirement will be met. [FR23]1 installed per manufacturer's j❑Does Not I J ;instructions. `❑Not Observable ;:Location on plans/spec:A- !❑Not Applicable 402.4.3 ;Fenestration that is not site built f❑Complies Requirement will be met. [FR20]1 ;is listed and labeled as meeting ❑Does Not AAMA/WDMA/CSA 101/I.S.2/A440 ❑Not Observable or has infiltration rates per NFRC I400 that do not exceed code E❑Not Applicable ; limits. , 402.4.5 j IC-rated recessed lighting fixtures ❑Complies :Exception: Requirement is [FR16]2 j sealed at housing/interior finish I❑Does Not not applicable. i and labeled to indicate :52.0 cfm ;leakage at 75 Pa. J❑Not Observable ; 1❑Not Applicable 403.3.1 ;Supply and return ducts in attics I❑Complies ;Exception: Ducts located [FR12]1 :insulated >= R-8 where duct is []Does Not :completely inside the >= 3 inches in diameter and >= t :building envelope. R-6 where< 3 inches.Supply and i❑Not Observable return ducts in other portions of 1 J❑Not Applicable ;the building insulated >= R-6 for ;diameter>= 3 inches and R-4.2 , .for<3 inches in diameter. 403.3.2 1 Ducts, air handlers and filter I❑Complies ;Requirement will be met. [FR13]1 i boxes are sealed with I❑Does Not ;joints/seams compliant with ` Location on plans/spec:A- ;International Mechanical Code or i❑Not Observable 1 :International Residential Code,as ❑Not Applicable applicable. 403.3.5 ;Building cavities are not used as j❑Complies ;Requirement will be met. [FR15]3 :ducts or plenums. ❑Does Not �J { ❑Not Observable ;!Location on plans/spec:A- I J❑Not Applicable 403.3.7 ;Ducts declared to be within the I❑Complies ;Requirement will be met. [FR28]3 :conditioned space are either 1) ❑Does Not ® ;completely within the continuous Observable !Location on plans/spec:A- ;air barrier and within the building 1 ;thermal envelope,2) buried S I❑Not Applicable ; ;within ceiling insulation in 1 accordance with Section 1 R403.3.6 and the air handler is { located completely within the I continuous air barrier and within f ) ; .the building thermal envelope j and the duct leakage is<= 1.5 II j cfm/100 square feet of 1 conditioned floor area served by ;the duct system,or 3)the ceiling j insulation R-value installed ; I against and above the insulated f duct>=to the proposed ceiling !insulation R-value, less the R- }c value of the insulation on the 111 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Carder-Tucker Addition Report date: 08/02/21 Data filename: Page 4 of 9 Section Plans Verified Field Verified # Framing/Rough-In Inspection Value Value Complies? Comments/Assumptions & Req.ID 403.4 i HVAC piping conveying fluids R- R- ;❑Complies ;,Exception: Requirement is [FR17]2 s above 105°F or chilled fluids ;❑Does Not 1 not applicable. below 55 IF are insulated to>_R- 3 ;❑Not Observable ❑Not Applicable 403.4.1 Protection of insulation on HVAC ❑Complies Exception: Requirement is [FR24]1 ;piping. ❑Does Not :not applicable. *11 ❑Not Observable ❑Not Applicable 403.5.3 f Hot water pipes are insulated to R- R- ;❑Complies !Exception: Requirement is [FR18]2 >_11-3. ElDoes Not !not applicable. a' ;❑Not Observable ❑Not Applicable 403.6 Automatic or gravity dampers are {❑Complies !Requirement will be met. [FR19]z i installed on all outdoor air (❑Does Not intakes and exhausts. :Location on plans/spec:A- ;❑Not Observable 11 ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Carder-Tucker Addition Report date: 08/02/21 Data filename: Page 5 of 9 Section Plans Verified Field Verified # Insulation Inspection Value Value Complies? Comments/Assumptions & Req.ID 303.1 ',All installed insulation is labeled } PComplies ;Requirement will be met. [IN13]2 M or the installed R-values !. ❑Does Not i provided. } ij ❑Not Observable IE]Not Applicable 402.1.1, ;Floor insulation R-value. R- R- ;❑Complies ;see the Envelope Assemblies 402.2.6 ❑ Wood El Wood ;❑Does Not ;table for values, [IN1]1 ❑ Steel ❑ Steel ;❑Not Observable ❑Not Applicable 303.2, ;Floor insulation installed per ElComplies Requirement will be met. 402.2.8 :manufacturer's instructions and ❑Does Not [IN2]1 in substantial contact with the Location on plans/spec:A- ID) ;underside of the subfloor,or floor y❑Not Observable 1 framing cavity insulation is in I❑Not Applicable contact with the top side of i I !.sheathing,or continuous ; insulation is installed on the underside of floor framing and {{{ extends from the bottom to the j :top of all perimeter floor framing i members. i 402.1.1, ;Wall insulation R-value. If this is a:, R- R- ;❑Complies ;See the Envelope Assemblies 402.2.5, amass wall with at least 1/2 of the El Wood ;❑ Wood ;❑Does Not :table for values. 402.2.6 :wall insulation on the wall ❑ Mass ❑ Mass ❑Not Observable [IN3]1 exterior,the exterior insulation ❑ Steel 1❑ Steel ;❑Not Applicable l©) :requirement applies(FR10). 303.2 ;Wall insulation is installed per ❑' Complies Requirement will be met. [IN4]1 :manufacturer's instructions. i❑Does Not ❑Not Observable :Location on plans/spec:A- {❑Not Applicable Additional Comments/Assumptions: 1 IHigh Impact(Tier 1) 12 IMediurn Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Carder-Tucker Addition Report date: 08/02/21 Data filename: Page 6 of 9 Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 402.1.1, ;Ceiling insulation R-value. R- R- ;❑Complies ;See the Envelope Assemblies 402.2.1, 1 Wood j❑ Wood :❑Does Not table for values. 402.2.2, ; ❑ Steel ❑ Steel 402.2.6 � '❑Not Observable [Fill' ;❑Not Applicable 303.1.1.1,:Ceiling insulation installed per ;❑Complies ;Requirement will be met. 303.2 ;manufacturer's instructions. j❑Does Not [FI2]1 ;Blown insulation marked every ( ,Location on plans/spec:A- 300 ft2. } ❑Not Observable 1 i ;❑Not Applicable 402.2.3 ;Vented attics with air permeable ;❑Complies ;Requirement will be met. [FI22]2 insulation include baffle adjacent ❑Does Not to soffit and eave vents that i :Location on plans/spec:A- extends over insulation. r {❑Not Observable 1 ( i❑Not Applicable 402.2.4 ;Attic access hatch and door ; R- ; R- ;❑Complies ;Requirement will be met. [FI3]1 :insulation>_R-value of the ❑Does Not adjacent assembly. ;Location on plans/spec:A- ❑Not Observable ,1 ❑Not Applicable 402.4.1.2 ;Blower door test @ 50 Pa. <=5 ; ACH 50 = ; ACH 50 = ;❑Complies ;Requirement will be met. [F[17]1 :ach in Climate Zones 1-2, and ;❑Does Not <=3 ach in Climate Zones 3-8. :Location on plans/spec:A- ❑Not Observable ,1 ❑Not Applicable 403.3.3 ;Ducts are pressure tested to ; cfm/100 ; cfm/100 ;❑Complies ;Exception:All ducts and air [F[27]1 ;determine air leakage with ft2 ; ftz ;❑Does Not handlers are located within ;either: Rough-in test:Total ;conditioned space. leakage measured with a ; :❑Not Observable pressure differential of 0.1 inch ; ;❑Not Applicable ; w.g.across the system including ;the manufacturer's air handler enclosure if installed at time of ;test. Postconstruction test:Total leakage measured with a pressure differential of 0.1 inch ; w.g.across the entire system ; including the manufacturer's air handler enclosure. 403.3.4 ;Duct tightness test result of<=4 ; cfm/100 ; cfm/100 ;❑Complies ;Exception:All ducts and air [FI4]1 cfm/100 f:2 across the system or f:2 ftz ;❑Does Not ;handlers are located within <=3 cfm/100 ft2 without air :conditioned space. handler @ 25 Pa. For rough-in ❑Not Observable tests,verification may need to ; ; ;❑Not Applicable occur during Framing Inspection. 403.3.2.1 ;Air handler leakage designated ;❑Complies ;Requirement will be met. [FI24]1 by manufacturer at<=2%of j❑Does Not design air flow. :Location on plans/spec:A- ❑Not Observable ;1 ( 1❑Not Applicable 403.Z.1 Programmable thermostats I ,❑Complies ;Requirement will be met. [FI9] installed for control of primary i❑Does Not heating and cooling systems and ;Location on plans/spec:A- initially set by manufacturer to ,❑Not Observable 1 code specifications. f ;❑Not Applicable 403.1.2 Heat pump thermostat installed ( ;❑Complies ;Exception: Requirement is [FI10]2 on heat pumps. FDoes Not not applicable. ' 1❑Not Observable ❑Not Applicable 403.5.1 R Circulating service hot water i I❑Complies ;Exception: Requirement is [FI11]2 ;systems have automatic or i❑Does Not not applicable. accessible manual controls. i I ;[:]Not Observable ( J❑Not Applicable j 1 I High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Carder-Tucker Addition Report date: 08/02/21 Data filename: Page 7 of 9 Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 403.6.1 ;All mechanical ventilation system ;❑Complies :Requirement will be met. [FI25]2 (fans not part of tested and listed i❑Does Not HVAC equipment meet efficacy ![]Not ;Location on plans/spec:A- and air flow limits per Table Observable ,1 i 1 R403.6.1. ❑Not Applicable 403.2 ;Hot water boilers supplying 2 heat ;❑Complies ;Exception: Requirement is (FI26] (through one-or two-pipe heating 1❑Does Not :not applicable. systems have outdoor setback I I control to lower boiler water I❑Not Observable (temperature based on outdoor ;❑Not Applicable ; �temperature. i 403.5.1.1 Heated water circulation systems ` ![]Complies !Exception: Requirement is [FI28]2 ;have a circulation pump.The J❑Does Not :not applicable. ;system return pipe is a dedicated 1 return pipe or a cold water supply ❑Not Observable I pipe.Gravity and thermos- ❑Not Applicable ;syphon circulation systems are 1 not present.Controls for ; circulating hot water system ! 1 pumps start the pump with signal 11 ; ;for hot water demand within the I occupancy.Controls ` 1 automatically turn off the pump II !when water is in circulation loop ; is at set-point temperature and I 1 no demand for hot water exists. i 403.5.1.2 Electric heat trace systems I❑Complies ;Exception: Requirement is [F129]2 ;comply with IEEE 515.1 or UL f❑Does Not not applicable. 1515.Controls automatically adjust the energy input to the []Not Observable I heat tracing to maintain the ❑Not Applicable ; desired water temperature in the 1 piping. 1 ; 403.5.2 ;Demand recirculation water I❑Complies :Exception: Requirement is [F130]2 systems have controls that ❑Does Not not applicable. i manage operation of the pump f and limit the temperature of the f ❑Not Observable water entering the cold water 4❑Not Applicable ; piping to<= 104°F. 403.5.4 !Drain water heat recovery units ❑Complies Requirement will be met. [FI31]2 !tested in accordance with CSA ❑Does Not i 1355.1. Potable water-side ;Location on plans/spec:A- 1 pressure loss of drain water heat ❑Not Observable j 1 !recovery units< 3 psi for ❑Not Applicable ;individual units connected to one or two showers.Potable water- !side pressure loss of drain water I ; j heat recovery units< 2 psi for 1 individual units connected to three or more showers. j 1 404.1 ;90%or more of permanent j ❑Complies :Requirement will be met. [FI6]1 (fixtures have high efficacy lamps.sIs 1❑Does Not f ❑Not Observable ;Location on plans/spec:A- ❑Not Applicable ;1 404.1.1 ;Fuel gas lighting systems have 1[]Complies ;Requirement will be met. [FI23]3 !no continuous pilot light. j❑Does Not 1 Q 1❑Not Observable Location on plans/spec:A- 1❑Not Applicable 401.3 1Compliance certificate posted. ;❑Complies Requirement will be met. [F17]2 1❑Does Not ; 1 { ;❑Not Observable j ;❑Not Applicable 1 I High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Carder-Tucker Addition Report date: 08/02/21 Data filename: Page 8 of 9 Section Plans Verified Field Verified # Final Inspection Provisions Value Value . Complies? Comments/Assumptions & Req.ID 303.3 ,Manufacturer manuals for 1❑Complies ;Requirement will be met. [FI18]3 1 mechanical and water heating i❑Does Not systems have been provided. I❑Not Observable I❑Not Applicable ; Additional Comments/Assumptions: 1 I High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 TLow Impact(Tier 3) Project Title: Carder-Tucker Addition Report date: 08/02/21 Data filename: Page 9 of 9 2018 IECC Energy Efficiency Certificate Insulation Rating R-Value Above-Grade Wall 24.60 Below-Grade Wall 0.00 Floor 30.00 Ceiling / Roof 49.00 Ductwork (unconditioned spaces): Door Rating U-Factor SHGC Window 0.29 Door CoolingHeating & Heating System: Cooling System: Water Heater, Name: Date: Comments 8 a 6 EXISTING BUILD & PROPOSED ADDITION 12' EXISTING RIGHT-OF-WAY PEA STONE UPPER COURSE PER DETAIL t EXISTING SLOPE a El I I I I I --EXISTING STONE I I WALL FIN. FLOOR ELEV. 410.75' ---- L \-�-24" SAND FILTER -1 r--- _MEDIUM PER DETAIL rr I I I f EXISTING STONE rrr L -J J WALL - UPON LAKE LEVEL- LAWN AREA Pr COMPLETION OF NEW CONCRETE WALL OWTS CHAMBER PROPOSED CONCRETE REMOVE THE TOP 12" WAL PROPOSED EFFLUENT RETAINING WALL ANDOSLOPEO NE MATERIAL PUMP CHAMBER BACK FILL MATERIAL INSTALL SAND MEDIUM AS EXISTING 6x6 POSTS TO PROTECT BETWEEN EXISTING SLOPE MATERIAL IS REMOVED PUMP CHAMBER AND STONE WALL AND NEW CONCRETE OWTS CHAMBER RETAINING WALL SITE SECTION 1" = 1o'-D" t l r RUCINSKI HALL ARCHITECTURE Ronald Richard Rucinski Ethan Peter Hall 134 Dix Avenue �JG Glens Falls NY 12801 Voice 518 741-0268 Fax 518 741-0274 Email ephall@nycap.rr.com Memo To: John O'Brien—Town of Queensbury—Code Enforcement From: Ethan Hall Date: 26 May, 2022 Re: Carder-Tucker residence—93 Fitzgerald Road—Hilltop Construction John, As discussed regarding the installation of the sewage disposal system that has been designed for the subject property the Owners have asked if they could utilize the existing sewage disposal system for the summer so that their father can continue to use the property on a limited basis until the fall when IBS can get on site and install the final sewage disposal system. As discussed the existing property has a right of way to the neighboring properties and the construction of the system has the potential to cause interruptions to the right of way for periods of time that, if done during the summer, would be detrimental to the neighbors. The existing system has been functioning property and remains intact and will be adequate for the use of the property by the Owner on a limited basis until the fall. The Owners have agreed to pump the tank prior to occupying the property and will pump it again as necessary during the summer. Once the summer lake season has past IBS will return as indicated in the attached letter from Eric Shipley and perform the installation beginning on October 3rd, 2022. If a temporary certificate of occupancy can be issued based on this information it would allow Caren's father to utilize the home for the weekends this summer. Please let me know if this is possible and if there are any additional items required. Regards, Ethan P. Hall Architect YACarder ResidenceTaperworkMemo-26 May 2022.doe IBS Septic-and Drain, ► I.LdWer Warren Street qu,e6ns.bury," NY 12804 S18-798-8194 May 20!':2022 Ref:Carter=Tqtker Ethan Hall We will start'work on 93:Fitzgerald-Road,Queensbury,NY 1 2804 on Qttober P.2022,to install at new treatment system and:field. Erit Shipley Y:\Carder Residence\Paperwork\Transmittal - 12 June 2023.doc 1 RUCINSKI HALL ARCHITECTURE Ronald Richard Rucinski Ethan Peter Hall 134 Dix Avenue Glens Falls NY 12801 Voice 518 741-0268 Fax 518 741-0274 Email ephall@nycap.rr.com Transmittal To: John O’Brien – Town of Queensbury – Code Enforcement Office From: Ethan Hall Date: 12 June, 2023 Re: Carder-Tucker Residence – 93 Fitzgerald Road – Final Acceptance & Septic As-built John, At the above referenced project location this office has made periodic site observations including the final installation of the sewage disposal system which has recently been completed by Ellsworth & Son Excavating. All work appears to be in accordance with the approved construction drawings and is acceptable to this office. We have included some photographs of the installation of the sewage disposal system and the septic plans labeled “As-built” for your files.\ If there are any additional items required please let me know. I believe this is the last of the outstanding items required to issue the permanent Certificate of Occupancy for the project. Regards, Ethan P. Hall Architect Y:\Carder Residence\Paperwork\Transmittal - 12 June 2023.doc 2 Y:\Carder Residence\Paperwork\Transmittal - 12 June 2023.doc 3 Y:\Carder Residence\Paperwork\Transmittal - 12 June 2023.doc 4 LANDS N/F OF Robert G Hogan EEEEEEE E E E E E E E R etaining W all LANDS N/F OF Roxbury Group Trust 289.14-1-23 289.14-1-27.2 415 415 4 15 4 10 4 10 410 4 104 1 0 410 405 4 05 16 .5'± 6 3 . 0' ± 2 7 . 0' ± Queensbury, New Yor k 12 8 0 4 93 Fitzgerald R oa d Ren ova tions to the Residenc e of E E 36'-1" LANDS N/F OF Clay Ashworth 289.14-1-25 Y:\ C a rde r R e si de n ce\ C -1. 4 - As-bu il t - Si te Pl an . d w g , 6 / 12 / 2 0 2 3 9 : 5 9 : 1 6 AM , p d f Facto ry.p c3 LANDS N/F OF Robert G Hogan EEEEEEE E E E E E E E R etaining W all LANDS N/F OF Roxbury Group Trust 289.14-1-23 289.14-1-27.2 415 415 4 15 4 10 4 10 410 4 104 1 0 410 405 4 05 6 3 . 0' ± 2 7 . 0' ± Queensbury, New Yor k 12 8 0 4 93 Fitzgerald R oa d Ren ova tions to the Residenc e of E E 36'-1" LANDS N/F OF Clay Ashworth 289.14-1-25 NTS · · · · · Y:\ C a rde r R e si de n ce\ C -1. 4 - As-bu il t - Si te Pl an . d w g , 6 / 12 / 2 0 2 3 9 : 5 9 : 3 1 AM , p d f Facto ry.p c3 Queensbury, New Yor k 12 8 0 4 93 Fitzgerald R oa d Ren ova tions to the Residenc e of Y:\ C a rde r R e si de n ce\ C -1. 4 - As-bu il t - Si te Pl an . d w g , 6 / 12 / 2 0 2 3 9 : 5 9 : 4 1 AM , p d f Facto ry.p c3 1'- 5 1/2" CRITICAL DIMENSIONS A B C D E F H G I J K L M N O P Q R S U T V W X Y Z CONTRACTOR'S CERTIFICATION: I (WE) HEREBY CERTIFY THAT THIS DRAWING HAS BEEN CHECKED AND IS APPROVED FOR USE IN CONFORMITY WITH THE CONTRACT DOCUMENTS. DATE: NAME: PROJECT ENGINEER'S APPROVAL: I (WE) HEREBY CERTIFY THAT THIS DRAWING HAS BEEN CHECKED AND IS APPROVED FOR USE IN CONFORMITY WITH THE CONTRACT DOCUMENTS. DATE: NAME: U.S. AND FOREIGN PATENTS PENDING © MMXVIII SINGULAIR® GREEN 960 - 500GPD SYSTEM DRAWN BY APPROVED BY REVISION DATE DATE SCALE DRAWING NO. REVISION BDS JMM 08-04-2010 NTS PC-5-7123 60° L U T H G S C F D E N M O Q R PLAN VIEW BIO-STATIC® SLUDGE RETURN ALTERNATE INLET LOCATION APPROVED SEALING DEVICE EXTENDED AERATION CHAMBER 4" DIAMETER INLET LINE PRETREATMENT CHAMBER ALTERNATE INLET LOCATION VENTED COVER SINGULAIR® AERATOR (SEE NOTE 1) AERATOR MOUNTING RISER UNDERGROUND POWER SUPPLY ENTRANCE APPROVED SEALING DEVICE PRETREATMENT CHAMBER SUBMERGED TRANSFER PORT EXTENDED AERATION CHAMBER SECTION A-A TRANSFER PORT AERATION CHAMBER FINAL CLARIFICATION CHAMBER BIO-KINETIC® SYSTEM (SEE DETAIL) SYSTEM DISCHARGE SINGULAIR® BIO-KINETIC® 4" DIAMETER APPROVED SEALING BIO-KINETIC® SYSTEM MOUNTING RISER BIO-KINETIC® SYSTEM DECHLORINATION SYSTEM OPTIONAL BIO-NEUTRALIZER® CHLORINATION SYSTEM OPTIONAL BLUE CRYSTAL® FINAL CLARIFICATION CHAMBER RISER AND COVER BIO-KINETIC® SYSTEM MOUNTING 4" DIAMETER EFFLUENT LINE APPROVED SEALING AND VENTED COVER AERATOR MOUNTING RISER RECEIVING FLANGE BIO-KINETIC® SYSTEM LOCKING LUGS GASKETED DISCHARGE FLANGE ASSEMBLY APPROVED SEALING DEVICE TO 4" DIAMETER EFFLUENT LINE BIO-KINETIC® SYSTEM DISCHARGE DETAIL BIO-KINETIC® SYSTEM MOUNTING RISER AND COVER GASKETED RISER RATED CAPACITY: 600 GALLONS PER DAY NOTE: TOTAL SYSTEM CAPACITY: 1,300 GALLONS OUTLET END VIEW K I DEVICE DEVICE B A EFFLUENT LINE GENERAL NOTES: SINGULAIR® AERATOR, AS TESTED AND ACCEPTED BY NSF. FALL THROUGH SINGULAIR®PLANT FROM INLET INVERT TO OUTLET INVERT IS FOUR INCHES. INLET INVERT IS 16 INCHES BELOW THE RISER MOUNTING SURFACE. ON DEEPER INSTALLATIONS, RISERS MUST BE USED TO EXTEND AERATOR MOUNTING RISER AND BIO-KINETIC® SYSTEM MOUNTING RISER TO GRADE. INSPECTION COVER ON PRETREATMENT CHAMBER MUST BE DEVELOPED TO WITHIN TWELVE INCHES OF GRADE. REMOVABLE COVERS ON RISERS ARE EACH SECURED TO PREVENT UNAUTHORIZED ACCESS. CONTACT THE LOCAL, LICENSED SINGULAIR® DISTRIBUTOR FOR ELECTRICAL REQUIREMENTS. 1 3 5 4 2 3'- 3" 3'- 5 1/4" 4'- 2 1/4" 2'- 8 3/4" 10'- 6 1/2" 1'- 4" 4'- 7 1/2" 0'- 0 3/8" 0'- 6" 0'- 0 3/8" 1'- 8" 4'- 3 1/2" 5'- 11 1/2" 1'- 4" 6'- 6" 0'- 3" 0'- 1 1/2" 1'- 0" 0'- 0 3/4" 4'- 4" LOCKING LUGS P 04-10-2018 G J A U A Queensbury, New Yor k 12 8 0 4 93 Fitzgerald R oa d Ren ova tions to the Residenc e of Y:\ C a rde r R e si de n ce\ C -1. 4 - As-bu il t - Si te Pl an . d w g , 6 / 12 / 2 0 2 3 9 : 5 9 : 5 1 AM , p d f Facto ry.p c3 SERVICE CONTRACT FOR THE FUJI CLEAN TREATMENT TECHNOLOGY Ellsworth & Son Excavating, Inc. has been contracted by Fuji Clean USA and their Authorized Distributor to provide you with the first two years of service, maintenance, and operation as well as any warranty service should it be required. This contract has been paid in full on your behalf. This contract is provided in accordance with applicable state and local regulations. This contract, entered into between Ellsworth & Son Excavating, Inc. and Caren Tucker shall be binding upon both parties in accordance with the conditions and terms set forth below: Contract Date: 5/5/2023 Term of Contract: 2 years Location of Technology: property address: 93 Fitzgerald Road Model: Fujiclean CE7 Maintenance and Other Services shall consist of: a. Inspection, Maintenance, and Operation: Service Provider agrees to inspect, maintain and operate the Fuji Clean treatment system per the TN DEC and manufacturer's requirements. This includes but is not limited to the following: - two service visits per year (6-month intervals). Service visits will include performance of operation and maintenance activities detailed in the Operation and Maintenance manual; check the sludge depth to determine the need for pumping; inspection of the final effluent to determine proper operational performance; and test the process parameters including but not limited to DO, pH, and turbidity to maintain proper operation; b. Service Calls: Service Provider will provide services calls within two business days. Service Provider will apply a charge for labor, travel time and shipping for any necessary replacement parts unless covered by the manufacturer's warranty. c. Completed inspection form will be submitted to local and state authorities as required. d. Contract is transferable in the event of sale of the home. The owner of the system agrees to use the system as outlined in the owner's manual. The owner also understands that any abuse of the system may void the manufacturer's warranty. Owner acknowledges that the following items can overtax the biological process of the system and shall avoid introducing dental floss, disposable diapers, kitty litter, sanitary napkins, tampons, cigarette butts, condoms and other items of similar nature. Owner acknowledges that the following can destroy the biological process and agrees to not introduce chemicals such as paints, varnishes, thinners, waste oils, photographic solutions, pesticides and excessive amounts of household chemicals into the system. The owner acknowledges that violation of these terms will void the manufacturer's warranty and may be in violation of state law. Homeowner: Date Service Provi Date 5 673 (Authorized Agent) Please sign and return to the Service Provider whose name and address appear below: Ellsworth & Son Excavating, Inc 10302 State Route 149 Fort Ann, NY 12827