Loading...
CC-0109-2023 Office Use Only _ J ADDITION/ALTERATION PERMIT Permit#:_ �- elc�� - ZOz3 Town o!Q zy, APPLICATION Permit Fee:$ 742 Bay Road,Queensbury,NY 12804 e, P:518-761-8256 www.gueensbury.net Invoice#: Flood Zone? Y N Reviewed By: Project Location: 75 Carey Road, Queensbury, NY, Tax Map ID #: 308'20_1 —3.'3 Subdivision Name: N/A PROJECT INFORMATION: TYPE: ❑ Residential 0 Commercial, Proposed Use: Tenant fitup ❑ Single-Family ❑ Two-Family ❑ Multi-Family (#of units_) ❑ Townhouse W Business Office ❑ Retail ❑ Industrial/Warehouse ❑ Garage (#of cars ) ❑ Other(describe ) ADDITION SQUARE FOOTAGE: ALTERATION SQUARE FOOTAGE: 1st floor: 1st floor: 3,000 2nd floor: 2nd floor: n/a 3rd floor: 3rd floor: n/a Basement (habitable space): Basement (habitable space)n/a Total sq ft: Total sq ft: 3,000 Scope of work to be done: Erect walls, ceilings and restrooms to develope office and warehouse space to for new tenant called Orkin pest control in the existing space. MAR 17 2023 TOW - uOLENS60i�r BUILDING &CODES Addition/Alteration Application Revised June 2022 ADDITION/ALTERATION Submission Requirements: ,m,,, (RESIDENTIAL AND COMMERCIAL) 742 Bay Road,Q rY ueensbu .NY 12804 P:618-761-8256 dvwvv.queensbury.net 1. Completed Addition/Alteration permit application (please print neatly or type) 2. Workers Compensation insurance information for ALL contractors involved in the project—this is REQUIRED EVEN FOR SOLE PROPRIETORS THREE (3) COPIES (either 1 pdf& 2 paper (min. 11" x 17") OR 3 paper (min. 11" x 17") OF THE FOLLOWING: 3. Structural drawings, which may include: a. Signed & sealed architect or engineer stamp IF the cost of construction is over$20,000 b. Floor plan, if applicable c. Foundation plan, if applicable d. Cross sections, if applicable e. Elevations, if applicable f. Windows & door schedules, if applicable—printed on the drawings is acceptable g. Calculation sheet for natural light, ventilation & emergency egress, if applicable—printed on the drawings is acceptable 4. Plot plan, using a survey map, if possible, which_ includes: a. Drawn to scale (i.e. 1 inch=30 feet) b. Indicate the proposed changes with setbacks to the property lines c. Include all structures on the property d. Include the location of water supply(well or water lines) e. Include the location & configuration of the septic system or sewer line 5. REScheck(for residential projects) or COMcheck (for commercial projects), signed and stamped, if applicable—please visit www.energycodes.gov for more information ADDITIONAL IMPORTANT INFORMATION: 1. Any changes to the approved plans prior to or during construction will require the submittal of amended plans, additional'reviews and re-approval. 2. If, for any reason, the building permit application is withdrawn, 30% of the fee is retained by the Town of Queensbury. After 1 year from the initial application date, 100% of the fee is retained. Addition/Alteration Application Revised June 2022 I CONTACT INFORMATION: PLEASE PRINT LEGIBLY OR TYPE, PLEASE INCLUDE AN EMAIL • Applicant: Name(s): Okie Properties, LLC Mailing Address, C/S/Z: PO Box 34, Cohoes, NY 12047 Cell Phone: ( )518-857-1555 Land Line: Email:zmikeoc1 @yahoo.com • Primary Owner(s): Name(s): Same Mailing Address, C/S/Z: Cell Phone: Land Line: � ) Email: ❑ Check if all work will be performed by property owner only • Contractor(s): (List all additional contractors on the back of this form) Contact Name(s): Contractor Trade: Mailing Address, C/S/Z: Cell Phone: Land Line: � ) Email: **Workers' Comp documentation must be submitted with this application** Arch itects)/Engineer(s): Business Name: Mark Bergreron Engineering Contact Name(s): Mark Bergreron, PE Mailing Address, C/S/Z: 62 Van Vranken Rd., Clifton Park; NY 12065 Cell Phone: Land Line: )518-723-9163 Email:mpdbindustries@aol.com Contact Person for Compliance in regards to this project: Michael A. O'Connor Cell Phone: ( )518-857-1555 Land Line: Email:zmikeoc1 @yahoo.com Addition/Alteration Application Revised June 2022 ADDITIONAL PROJECT INFORMATION: 1. Estimated Cost of Construction:$ $45;000.00 2. Source of Heat (circle one): W Gas ❑ Oil ❑ Propane ❑ Solar ❑ Other: Fireplaces/inserts need a separate Fuel Burning Appliances & Chimney Application 3. Are there any structures not shown on the plot plan? ❑ YES 0 NO Explain: 4. Are there any easements on the property? ❑ YES 0 NO SITE INFORMATION: • Is this a corner lot? ❑ YES 0 NO • Will the grade be changed as a result of the construction? ❑ YES 0 NO • What is the water source? W PUBLIC ❑ PRIVATE WELL • What type of wastewater system is on the parcel? k SEWER ❑ PRIVATE SEPTIC DECLARATION: 1. I acknowledge that no construction shall be commenced prior to the issuance of a valid permit and will be completed within a 12 month period.Any changes to the approved plans prior to/during construction will require the submittal of amended plans, additional reviews and re-approval. 2. If,for any reason,the building permit application is withdrawn, 30%of the fee is retained by the Town of Queensbury. After 1 year from the initial application date, 100% of the fee is retained. 3. If the work is not completed by the 1 year expiration date the permit may be renewed, subject to fees and department approval. 4. 1 certify that the application, plans and supporting materials are atrue and a complete statement and/or description of the work proposed,that all work will be performed in accordance with the NYS Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. 5. 1 acknowledge that prior to occupying the facilities proposed I, or my agents, will obtain a certificate of occupancy. 6. 1 also understand that I/we are required to provide an as-built survey by.a licensed land surveyor ofall newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: PRINT NAME: Michael A. O'Connor SIGNATURE: DATE: 1 1/30/2022 Addition/Alteration Application Revised June 2022 FIRE MARSHAL'S OFFICE Tozvn of Queensbury 742 Bay Road, Queensbury, NY 12804 "Home of Natural Beauty ... A Good Place to Live PLAN REVIEW Orkin/Okie Properties 75 Carey Rd CC-0109-2023 1588 S.F. Business Office Alteration 3/20/23 I have reviewed the submitted drawings for the above project; and offer the following comments: 1) Verify Storage 2) Verify operation of existing exit/ emergency lights. 3) Verify paths of egress 4) Verify Knox Box Key 5) Truss ID 6) CO Detection required 7) NFPA 704 Signage needed marking of Chemicals in building (also amount of Chemicals being stored) Deputy Fire Marshal Tyson Converse 742 Bay Road Queensbury NY 12804 518 7618205 tysonc@queensbury.net Fire Marshal's Office Phone: 518-761-8206 Fax: 518-745-4437 {ireniarshal fteensbulil.net 7uzvMqueensbu-n1met Northeastern Air Quality, Inc. P.O. Box 3271 Albany, New York 12203 (518) 857-3641 HVAC SYSTEMS TESTING: Project:75 Carey Road Location:Queensbury, New York Architect: Engineer: Piping: Sheet Metal: Date:June 9, 2023 Prepared by:R. Kelley Air Balance Report CERTIFICATION PROJECT: ADDRESS: TESTING AND BALANCING FIRM: CERTIFIED BY:DATE:6/9/2023 SIGNATURE: Robert V. Kelley 75 Carey Road #REF! THE DATA PRESENTED IN THIS REPORT IS AN EXACT RECORD OF SYSTEM PERFORMANCE AND WAS OBTAINED IN ACCORDANCE WITH NEBB STANDARD PROCEDURES. ANY VARIANCES FROM DESIGNED QUANTITIES WHICH EXCEEDS NEBB TOLERANCES ARE NOTED THROUGHOUT THIS REPORT. THE AIR DISTRIBUTION SYSTEMS HAVE BEEN TESTED & BALANCED AND FINAL ADJUSTMENTS HAVE BEEN MADE IN ACCORDANCE WITH NEBB ''PROCEDURAL STANDARDS FOR TESTING AND BALANCING OF ENVIRONMENTAL SYSTEM'' AND THE PROJECT SPECIFICATIONS. Northeastern Air Quality, Inc. #3159 Page 2 Northeastern Air Quality, Inc. P.O. Box 3271, Albany, NY 12203-0271 (518) 857-3641 PROJECT: THE FOLLOWING IS A LIST OF STANDARD ABBREVIATIONS WHICH MAY APPEAR IN THIS REPORT: MEANING MEANING A AMPS or AMPERAGE NL NOT LISTED ACH AIR CHANGES PER HOUR NOM NOMINAL AD ACCESS DOOR NOM EFFY NOMINAL EFFICIENCY ADJ ADJUSTABLE NR NOT REQUIRED Ak KINETIC (EFFECTIVE FREE) AREA NS NOT SPECIFIED BG BLAST GATE OBD OPPOSED BLADE DAMPER BHP BRAKE HORSEPOWER OED OPEN END DUCT CALC CALCULATED PF POWER FACTOR CALIBR CALIBRATION or CALIBRATED PH PHASE CD CEILING DIFFUSER Ps STATIC PRESSURE CF CUBIC FEET Pt TOTAL PRESSURE CFM CUBIC FEET PER MINUTE Pv VELOCITY PRESSURE cL CENTERLINE RG RETURN GRILLE CLG CEILING RPM REVOLUTIONS PER MINUTE CR CEILING REGISTER RR RETURN REGISTER CS CIRCUIT SETTER SBD SINGLE BLADE DAMPER CSD CEILING SUPPLY DIFFUSER SD SMOKE CONTROL DAMPER DD DIRECT DRIVE SF SERVICE FACTOR DDC DIRECT DIGITAL CONTROL SMC SHEET METAL CONTRACTOR DISC DISCONNECT SWITCH SPS STATIC PRESSURE SENSOR DISCH DISCHARGE SR SUPPLY REGISTER DPR DAMPER TC TEMPERATURE CONTROL DR PRESSURE DIFFERENTIAL TCC TEMPERATURE CONTROL CONTRACTOR EC END CAP TCD TEMPERATURE CONTROL DAMPER ER EXHAUST REGISTER TP THERMALLY PROTECTED FL BHP BRAKE HORSEPOWER @ FULL LOAD AMPS TRAV DUCT TRAVERSE FLA FULL LOAD AMPS V VOLTS or VOLTAGE FTR FINNED TUBE RADIATION VAR VARIABLE GPM GALLONS PER MINUTE VBD V-BELT DRIVE HP HORSEPOWER VD VOLUME DAMPER LD LINEAR DIFFUSER VEL VELOCITY LF LINEAR FEET (NOMINAL)W WATTS or WATTAGE NA NOT ACCESSIBLE WG WALL GRILLE ND NO DAMPER WMS WIRE MESH SCREEN NDRG NON-DUCTED RETURN GRILLE WR WALL REGISTER NG NO GAUGE ZD ZONE DAMPER NI NOT INSTALLED NIC NOT IN CONTRACT ABBREVIATIONS 75 Carey Road ABBREVIATION ABBREVIATION Page 3 Northeastern Air Quality, Inc. P.O. Box 3271, Albany, NY 12203-0271 (518) 857-3641 6/9/2023 MOTOR NAME-RPM PLATE VOLTS HERTZ 230 60 DATA EXT. STATIC PRESSURE VOLTS AMPS BHP (calc.) REMARKS: * NOTE: If P.F. or NOM EFFY are NL, (P.F. x NOM EFFY) = 746Hp/(VAX), where X = 1 if 1 Ph, and 1.73 if 3 Ph DISCHARGE NL 0.22 NL INLET NL 0.12 0.34 NL OUTSIDE AIR CFM 150 162 TOTAL 0.50 TOTAL CFM - OUTLETS 1000 1005 RETURN AIR CFM 850 817 TOTAL CFM - FAN 1000 - SHEAVE cL DISTANCE BELTS FAN SHEAVE FAN RPM Direct Drive Direct Drive Direct Drive CALCULATED (P.F. x NOM EFFY) * MOTOR SHEAVE STARTER HEATER ELEMENTS 0.72 TEST DATA DESIGN ACTUAL DESIGN ACTUAL P.F.NOM EFFY -- Direct Drive HP 1/2 1800 PHASE 3 FL AMPS S.F.2.1 - DATE TESTED:6/9/2023 MANUFACTURER endura STYLE FRAME PROJECT:75 Carey Road TESTED BY:R. Kelley DATE: AIR MOVEMENT EQUIPMENT TEST SHEET SERVICE:Offices MANUFACTURER:Samsung MODEL:AC030BNZDCH/AA SERIAL NUMBER:BLT1P9ATC00106D SYSTEM:AHU-1 LOCATION:Mezenine T1 - T2 230 230 T2 - T3 (3 Ph only)230 T1 - T3 (3 Ph only)230 T1 2.1 1.1 T2 (3 Ph only)1.1 T3 (3 Ph only)1.1 F.L.A.ACTUAL -0.42 Page 4 Northeastern Air Quality, Inc.GRILLE, REGISTER & DIFFUSER REPORT P.O. Box 3271, Albany, NY 12203-0271 PROJECT: (518) 857-3641 TESTED BY:DATE: REMARKS: DESIGN INITIAL INTERMEDIATE FINAL % OF NO.LOCATION SIZE MODEL Ak VEL CFM VEL CFM VEL CFM VEL CFM DES DATE REMARKS AHU-1 1 Entrance 24" x 24" 130 Hood 127 Hood 137 105%6/9/2023 2 Entrance 24" x 24" 130 Hood 129 Hood 140 108%6/9/2023 3 Entrance 24" x 24" 130 Hood 120 Hood 130 100%6/9/2023 4 Front Office 24" x 24" 120 Hood 158 Hood 130 108%6/9/2023 5 Midle Office 24" x 24" 120 Hood 60 Hood 118 98%6/9/2023 6 Back Office 24" x 24" 120 Hood 100 Hood 117 98%6/9/2023 7 Back Door 24" x 24" 100 Hood 70 Hood 93 93%6/9/2023 8 Back Storage 24" x 24" 150 Hood 97 Hood 140 93%6/9/2023 Total 1000 861 1005 101%6/9/2023 Return 9 Entrance 24" x 24" 425 Hood 351 Hood 411 97%6/9/2023 10 Back Storage 24" x 24" 425 Hood 387 Hood 406 96%6/9/2023 Total 850 738 817 96%6/9/2023 OA 11 Unit 6" R 0.20 764.331 150 600 118 823 162 108%6/9/2023 R. Kelley 6/9/2023 75 Carey Road High SpeedMed. Speed Page 5 Mark P. Bergeron, PE 62 Van Vranken Road Clifton Park, NY 12065 Cell: (518) 248-0906 Email: mpbdindustries@aol.com July 11, 2023 Town of Queensbury Building Dept. 742 Bay Road Queensbury, NY 12804 Attn: Assistant Building Inspector – Mark Smith Re: Orkin Tenant Fit up, Suite 4 75 Carey Road Queensbury, NY 12866 Construction Completion Gentlemen: This letter serves to certify that I or an associate has made periodic inspections throughout the course of construction for the above referenced project. To the best of my knowledge, the construction has been completed in satisfactory conformance with the approved updated plans dated 6-14-23. If you have any questions, please contact me. Sincerely, Mark P. Bergeron, PE Cc: Okie Properties – Mike O’Conner C 11 V r V,AR 17 2B23 o \,.a' jf ,` r/ill,' � � \\\ ��•� o� \� 1 i IT At . /^'t � � � I �r..�i�■�i r��"ti�-rsia.wC�e��!C i-� 7,�i��■�������4�����i������� 03 r•20-1nj -3,3 75 �a e O e Pr, C -0109-2023 Interior Alteration,Ste 4 s Z 5gg s.f Huv�H �►Iv�� VICINITY 'MAC`' C N,T,S) I..�...611 a N P • e.1•to"F CAPPEV IPON PS017 FOUNP e f.R.F (?V>N AD9 FeLINb Q F.,V, LttiPEA&PVAUfyt7 l-t�GTi tL TRAt�SP4�PrMf� ► o TV,1 TV GAS LE 00A o rip, TEI..EPHPNE W)( o "5 510 9ANITAFI`f SEWEP4 �7HL1T PFF APX Q W 0 WATER LINE 15,1-1t.IT P F WY, 0 t', I , V FiA1 N itil.- -r (� NUMP.�EPt OF �irD�ULAPt PA�r►�II,16 �►'�'AC�S NAND t GA, F' AGC�.�a51•�l..E �'A'R �t hl6 �PAG1✓ 0- F-(LON L10HT 9TAN1;>ARI7 b M•$, E1.-EGTIG. METESQx, 13 NAT U F%AL 6A5 N1F-T1:Pi MAGAPIAM PAYED A -z 7. GP NC?►E•TE rAP L}�I,,N� P j►OtPi, p�►I�oi�1� {'DIN'T OF M&IuN IP° & f=L.GPP FL..A1 N NPT (�;TATa M E� NT OF n NCP 1OACH M NTS ® UNV1=•ta►4►MPWNP tF-LEGT1''\1C• VAULT AZ4V r1 PNE a?C LdcATTEP IN 744l: NPP►TH WF-5,T (-,mNSP+ of 5wvur-r-T ?F`Iv F-1; TY EN4,MOAaH 04 *1a15TF.GT t7WorfLP%71- AS SHOWN e OF N ILI W � L-oT # 10.7 O�Y C f�A# Hla rL.0TTIW.0 ONL'Yj 5UD3-aCT f-fWraMTY I5 L.pGATEP 1N 7oNE 1°G" of THE FLLOPV PiATr- (w,5UmANC-V MAP, GoMMUN•ITY f01ANV,L Not 3(pPBPT� vo2.5P, WHtGH 1KMt , AN F-FFV-C%TlVE t7ATE OF JU LY I (o ,1 4 AN 12 1 S7 -NOT LPGATEP 11I TH I N THE 109 YEAR FL.OPP MAIN, pljo R4 A .JT I L 1 T( 5 NPTE Li ! , Tm '7cmat;�u L+P-. 1tv�` l t�i FER'ENGE•P 5UP5P1vispipN MAP FIl.EP IN OvF-vwZE wr GAIN NVT A5 MAP E-3 SHpWs W FT WIVIR UTILA-rY EASlirMaNT ALdN& C:API%EY SAP, THIS EASF-MENT Vigmev AFFSGT -c;,u0TEGT PtwrwmTY AWV T445 N01;NT0EASTr--MLY VDUNvAI;�C IS, r0TTF-P AWt:7 ,ePWWM, P►EFERF-NC%Etb 5UtW)\/t1FP10N MAP AL*v BHP W6 $UILPtN& 4"F�TVoo,\C'S LINES, THEcgE AFFF-,;T SUPaTFGT t'R9F'F;MTY AN17 Ate i'LDTT51P ANC SHOWN, ZO FT WIVE. SASV-MV-N-'T TO THE NIACvAAA WHAWK FvWEPV avRPPAATIaN PA C:©RP1= 1K 1-1OF-Pi 50,91b CM, 9:&, TNIS 5AAaEMrNT ArFF,C-riS THF. rmPv-rmTY AN% t`., PLPTTf I7 At4P rx.,NaWN,, LAt417ev N/F Mt 1. MAC U �A CDnrC1RA`TIPN L, 5iil C,F g LVT # It ,?,25`,0'0 FT. v we ' r3 'AfptEA = �; to 5, A G • - 47 IV b �4" NZ Nv • �� �,y - k • fat& ® A r, 5 0U = OP 5sv-ovt!42!w .. p,UlL1a1N6 5E`t P�AG� � �- �-OT t941 ; v�1 �.. I?rpS�PE•P�TI'E a, _ is THE LdCAT141N PF LtTI L.ITIPS rvH6W N f-15FR150N AP , F=fRPM1 CIOOSFWFY P .Y1CaENC. o1+ ADOti/F, 6vP\PuNa A1:`FWc Tr,-1JANG15r7 ONLY, 2 , Fp�OM ooeoP4VEt7 Aewg SRC UNP AfrUPVTr-NAUGES P -Yj THE SUSTU-T PPIQ P E PVT Y 15 ER`/1= F $Y C-jAS r F-Ut✓ CTFO L WATF�'V, 57TGP\M SF-WER, ANP 5ANITARY tf-wEI� LINE151 AvAILA15,1.E ALONG ANP/PV% WITHIN THE PUPLIG KOAP FW-4 tT PF WAY OF GAIiF-Y ?\PAP., 40N 1 W.PF 11140-T :. AS 'rF-A MAP F1LEP IN O�fEP�SIZE MAr CAINNET Ay MAP tr-3, THE FC1U-PWING C•UNPITIPTt� APiF- 5HOV414 !, 5�' FRaNT aETP�AGI�i IrINE 2, 3,0' evI PIG ASP P\FAF% 6f-T1!7ACK L1 R" 15 P\I~ G U LAR PAPNK IN 6 SPAaE6 + 1 HANDI'.,AP Mnll�tN& SP'ACA I VEYENTIPN INFU-TMATIPN kF A I 12oo S,F. 1wILt;,IN6 r ALL THAT LOT, rIECE, dK PAPNC M- OF LAN12 51TWATP- 1N THF- TOWN PF A uIVXNSPU FAY, CPU NTi' OF `8AMmF-N , STATE AF NEW YPF%1Ai , SE I N6, LOT 04), ALL Ad-v -vH0WN ON A MAP F-WT1TL•--P 1' M0KTHF..Fx%N t7IeTni�LtT1t4"� SU�PIYI+SIP�N > TOWN Pf= OUVIEN5,1�,UP�Y PHASE 2'; J Yy F�tST_ F•P1rcoT AGa,i�OCAAT5S j y'G, j PATEP Fis04vtU.Ar�Y 01�89 r AN"G F•iLzv IN TH.- WARPWN GDUNTY CLF-P%6'S CFFIGE• (9N VCTPWIF�M 31 114 THE tP)(EFie7IZ•I MAr GAS I W F-T A,5 MAP -- , 15AIP LaT PeING• MORE TwA?171G1JLAFSLY ?,,(}`uNPt�P AND AS rO 1.1.0 W5 : - t�F-evINh1I96 AT AN WSP14 POP FIPuNP IN THE;-Ar;rrF- L'"- LINE 4F CA Pi p AP IT 15 It4TEPiSF-e-TEF WY THE t71v15147N L-1Nls Or LOT44 ON THP. NPP.J-r+j ANP L.07 #'!� ON -THIS SOUTH ANP RUNS r THIENGr, AI_pNCv. SAIP t7)VIS10N LIME, 279,Oo fmT TP A CAt'PER IFwN Rot, FcuwP1 nj NGr- 5�a° AL046, THE vIY15ipm MINI: aF LvT CI rN THE• EAeTANP LvT #1 ON THE WEST 32 ,av FT, IP AN IPtoN Rt7P FoUNtP 11+1 714E WmT+JIZ tt~Y WN1: OF C AP�V:-( F%VAP, THENM WK!,TE.FtI.:rAWP WRTt-F-Sl.Y AtPNe,-THE MMTH W� LY ANP aAe)T MP' 1V`t' O N TH E A Rr-P A CAWICL,S GUKIIN& TO THF_ P1&HT +•IAYIN6- A C•V-NTRAL• AN6.1.-E Of "W-Q0'-W A C?IU OF 275,l7P FT, r:tOM AN APiG vleTANcs pF ,4'31t ? FT TaA MIRTJ T1-tE1`46E N 5'-PO�-42"M ANP CONT•(NUIN& AI.ANO 5�AIV J5A 7r=P%LY L-tNa OF C^AMV.,Y PWAp) ItV,ov FT TP THE PAINT ANP f LACF- OF ?�rE+,INNIN6,< U7 NT,A I N I N& ►, WS, Aat II:-5 bF LANP MOP1F-.*Fi GM?i"TI F'II^ATtON �4OT . s ( TITI.F- t�EPOPNT No, I9�0-0241 WA5 fw1 V415HHf-p 5 r , ±,,..4• F wr•r. I s'c t o h.r• Y' : G :.*` r s- ?R -,r F :. r i 1 t -71 :W;_ f i'f �,.. is C.PK'IFY THE HF-Mt=-IN To OY�{E PRJ7P P1Tl 5, Ll-l- �� !"`-Yt'ANh RATtPRA.L At�OeIATION, ITS evuu a5o.7ap 5� ANP/OR A 16Nc;:, A5 THEY°.\ 1HTF-P�E5TSF MAY AM-Ah ; GHI "C*P TITLE NSUFANGE. CPMY"AWY *- -rHl5 I5 TP GEF►TI y THAT TH►5 MAP PM PLAT ANV TH9 c,-1WF%\/WI'Pt4 -WHICH (T 15 ';AS 17 W1rP\F- MAPS Ito ,14C'W?ivANcF- V41T44 THE '2011 MINIMUM .PTANPAPIP VSTAIL PIE,L11P%EWISNT5► F©M AL.7A /ABM L Nt TITL.F, S14PTVE:Y5� 7PIN7�Y 1=6TAELI5REP AND APvPTMtP PP( AL.TA 4,p N5rs' ; M>a INei upe IT.Ma 1-4j6t-7A,0>-i10))ANP 13OFTALE.A-Mr-�F, T-I a F 1 ELt7 Wo1P, K WAS e-,0M PL.ETZr> c)t MAC op, 'Zolg� , t*7 s Or- P I -AT - MAY 2 I t 2v I�, `�I6NI=P: VAN1516IN 1.ANt� SUt�Y$Y{Nb� L4L P►v, �X i2 N -Y, 12.101 F,Ev{ 511PNf1: th N► 17ANSAIN 'rU*.*5am- MAR 17 e Y, OF ---- 3 f r 308.20-1-3.3 CC-0109-2023 Orkin/Okie Properties 75 Carey Rd, Ste 4 Interior Alterations 1588 s.f. D' is, W - ZCW-P-: t",,-.4O1 A L.-TA /ACM L. AN .TITLE. U PSI' E*-r 1 Y NOW N A :# I CA' Y 1 AP `PW N P P fWEE1�►SU F I F-t-V : M:rp WAMF N. cal w', PATE.: MAY 21, 2o19 Foh . F{LF / f M4e-.,GSC.AtP►E.Y>'� C' heals MMFa \\�\�t1{i 9 P IIl6�rgE 0 VN�Nfq YO © s 7