Loading...
TAB Report - ImmunotekNortheastern Air Quality, Inc. P.O. Box 3271 Albany, New York 12203 (518) 857-3641 HVAC SYSTEMS TESTING: Project:Immunotek Location:Queensbury, New York Architect:Lonnie Smith Architect Richmond, Kentucky Engineer:The Roberts Group, PSC Lexington, Kentucky Piping: Sheet Metal:Cerrone Plumbing, Heating & AC Queensbury, New York Date:June 23, 2023 Prepared by:N. Mailly Air Balance Report RKelley@NortheasternAirQuality.com Page 1 of 15 Item Page Certification 3 Standard Abbreviations 4 Air Balance Report Air Moving Equipment 5 Fan Test Report Sheets 8 Grille, Register & Diffuser Report 9 Minimum Outside Air Report 14 System Diagrams 15 Table of Contents Page 2 of 15 CERTIFICATION PROJECT: ADDRESS: TESTING AND BALANCING FIRM: CERTIFIED BY:DATE:6/23/2023 SIGNATURE: Robert V. Kelley Immunotek Queensbury, New York THE DATA PRESENTED IN THIS REPORT IS AN EXACT RECORD OF SYSTEM PERFORMANCE AND WAS OBTAINED IN ACCORDANCE WITH NEBB STANDARD PROCEDURES. ANY VARIANCES FROM DESIGNED QUANTITIES WHICH EXCEEDS NEBB TOLERANCES ARE NOTED THROUGHOUT THIS REPORT. THE AIR DISTRIBUTION SYSTEMS HAVE BEEN TESTED & BALANCED AND FINAL ADJUSTMENTS HAVE BEEN MADE IN ACCORDANCE WITH NEBB ''PROCEDURAL STANDARDS FOR TESTING AND BALANCING OF ENVIRONMENTAL SYSTEM'' AND THE PROJECT SPECIFICATIONS. Northeastern Air Quality, Inc. #3159 Page 3 Northeastern Air Quality, Inc. P.O. Box 3271, Albany, NY 12203-0271 (518) 857-3641 PROJECT: THE FOLLOWING IS A LIST OF STANDARD ABBREVIATIONS WHICH MAY APPEAR IN THIS REPORT: MEANING MEANING A AMPS or AMPERAGE NL NOT LISTED ACH AIR CHANGES PER HOUR NOM NOMINAL AD ACCESS DOOR NOM EFFY NOMINAL EFFICIENCY ADJ ADJUSTABLE NR NOT REQUIRED Ak KINETIC (EFFECTIVE FREE) AREA NS NOT SPECIFIED BG BLAST GATE OBD OPPOSED BLADE DAMPER BHP BRAKE HORSEPOWER OED OPEN END DUCT CALC CALCULATED PF POWER FACTOR CALIBR CALIBRATION or CALIBRATED PH PHASE CD CEILING DIFFUSER Ps STATIC PRESSURE CF CUBIC FEET Pt TOTAL PRESSURE CFM CUBIC FEET PER MINUTE Pv VELOCITY PRESSURE cL CENTERLINE RG RETURN GRILLE CLG CEILING RPM REVOLUTIONS PER MINUTE CR CEILING REGISTER RR RETURN REGISTER CS CIRCUIT SETTER SBD SINGLE BLADE DAMPER CSD CEILING SUPPLY DIFFUSER SD SMOKE CONTROL DAMPER DD DIRECT DRIVE SF SERVICE FACTOR DDC DIRECT DIGITAL CONTROL SMC SHEET METAL CONTRACTOR DISC DISCONNECT SWITCH SP STATIC PRESSURE DISCH DISCHARGE SPS STATIC PRESSURE SENSOR DPR DAMPER SR SUPPLY REGISTER DR PRESSURE DIFFERENTIAL TC TEMPERATURE CONTROL EC END CAP TCC TEMPERATURE CONTROL CONTRACTOR ER EXHAUST REGISTER TCD TEMPERATURE CONTROL DAMPER FL BHP BRAKE HORSEPOWER @ FULL LOAD AMPS TP THERMALLY PROTECTED FLA FULL LOAD AMPS TRAV DUCT TRAVERSE FTR FINNED TUBE RADIATION V VOLTS or VOLTAGE GPM GALLONS PER MINUTE VAR VARIABLE HP HORSEPOWER VBD V-BELT DRIVE LD LINEAR DIFFUSER VD VOLUME DAMPER LF LINEAR FEET (NOMINAL)VEL VELOCITY NA NOT ACCESSIBLE W WATTS or WATTAGE ND NO DAMPER WG WALL GRILLE NDRG NON-DUCTED RETURN GRILLE WMS WIRE MESH SCREEN NG NO GAUGE WR WALL REGISTER NI NOT INSTALLED ZD ZONE DAMPER NIC NOT IN CONTRACT ABBREVIATIONS Immunotek ABBREVIATION ABBREVIATION Page 4 of 15 Northeastern Air Quality, Inc. P.O. Box 3271, Albany, NY 12203-0271 (518) 857-3641 6/16/2023 MOTOR NAME- PLATE VOLTS HERTZ 208 60 208 60 DATA EXT. STATIC PRESSURE VOLTS AMPS BHP (calc.) SYSTEM: LOCATION: PHASE FL AMPS HP DATE TESTED: MANUFACTURER SERVICE: MANUFACTURER: MODEL: S.F. * NOTE: If P.F. or NOM EFFY are NL, (P.F. x NOM EFFY) = 746Hp/(VAX), where X = 1 if 1 Ph, and 1.73 if 3 Ph T1 - T3 (3 Ph only) F.L.A.ACTUAL T2 (3 Ph only) T3 (3 Ph only) TOTAL CFM - FAN DISCHARGE OUTSIDE AIR CFM TOTAL TOTAL CFM - OUTLETS RETURN AIR CFM INLET T1 T1 - T2 T2 - T3 (3 Ph only) REMARKS: NOM EFFY CALCULATED (P.F. x NOM EFFY) * MOTOR SHEAVE STARTER HEATER ELEMENTS BELTS FAN SHEAVE STYLE FRAME FAN RPM SHEAVE cL DISTANCE TEST DATA P.F. SERIAL NUMBER: RPM AIR MOVEMENT EQUIPMENT TEST SHEET PROJECT:Immunotek TESTED BY:N. Mailly DATE: RTU-1 RTU-2 Roof Roof Entry / Wait / Reception Donor Floor Trane Trane YHC092F3RHA29G7C1A1A YHC102F3RHA29G7C1A1A 224014415L 224610833L 6/16/2023 6/16/2023 Ebmpapst Ebmpapst -NL -NL 2300W 1620 2300W 1620 3 3 7.0 1.10 7.0 1.10 NL NL NL NL 0.72 0.72 -- Direct Drive Direct Drive Direct Drive Direct Drive Direct Drive Direct Drive Direct Drive Direct Drive DESIGN ACTUAL DESIGN ACTUAL NL -NL - 2700 -3400 - 3025 2981 3400 3086 2825 2353 3000 3008 200 392 400 804 NL 0.35 NL 0.39 NL -0.62 NL -0.83 0.50 0.97 1.00 1.22 208 209 208 209 208 208 207 208 7.0 5.1 7.0 6.7 5.2 6.7 5.1 6.8 1.78 2.34 Page 5 Northeastern Air Quality, Inc. P.O. Box 3271, Albany, NY 12203-0271 (518) 857-3641 MOTOR NAME- PLATE VOLTS HERTZ DATA EXT. STATIC PRESSURE VOLTS AMPS BHP (calc.) SYSTEM: LOCATION: PHASE FL AMPS HP DATE TESTED: MANUFACTURER SERVICE: MANUFACTURER: MODEL: S.F. * NOTE: If P.F. or NOM EFFY are NL, (P.F. x NOM EFFY) = 746Hp/(VAX), where X = 1 if 1 Ph, and 1.73 if 3 Ph T1 - T3 (3 Ph only) F.L.A.ACTUAL T2 (3 Ph only) T3 (3 Ph only) TOTAL CFM - FAN DISCHARGE OUTSIDE AIR CFM TOTAL TOTAL CFM - OUTLETS RETURN AIR CFM INLET T1 T1 - T2 T2 - T3 (3 Ph only) REMARKS: NOM EFFY CALCULATED (P.F. x NOM EFFY) * MOTOR SHEAVE STARTER HEATER ELEMENTS BELTS FAN SHEAVE STYLE FRAME FAN RPM SHEAVE cL DISTANCE TEST DATA P.F. SERIAL NUMBER: RPM 6/16/2023 208 60 208 60 6.1 3.2 2.14 1.13 209 211 7.0 6.1 6.0 3.2 6.1 3.2 1.00 1.15 0.50 0.45 208 211 208 211 210 210 400 432 100 101 NL 0.30 NL 0.19 NL -0.85 NL -0.26 3400 -1200 - 3200 3036 1200 1197 2800 2956 1100 1083 Direct Drive Direct Drive DESIGN ACTUAL DESIGN ACTUAL NL -NL - 0.72 0.72 -- Direct Drive Direct Drive Direct Drive Direct Drive Direct Drive Direct Drive 3 3 7.0 1.10 6.0 1.10 NL NL NL NL Ebmpapst Genteq -NL -NL 2300W 1620 3.40 NL Donor Floor Sterile Supply Trane Trane YHC102F3RHA29G7C1A1A YHC036E3RLA29G0C1A1A 224515104L 224511644L 6/16/2023 6/16/2023 AIR MOVEMENT EQUIPMENT TEST SHEET PROJECT:Immunotek TESTED BY:N. Mailly DATE: RTU-3 RTU-4 Roof Roof Page 6 Northeastern Air Quality, Inc. P.O. Box 3271, Albany, NY 12203-0271 (518) 857-3641 MOTOR NAME- PLATE VOLTS HERTZ DATA EXT. STATIC PRESSURE VOLTS AMPS BHP (calc.) SYSTEM: LOCATION: PHASE FL AMPS HP DATE TESTED: MANUFACTURER SERVICE: MANUFACTURER: MODEL: S.F. * NOTE: If P.F. or NOM EFFY are NL, (P.F. x NOM EFFY) = 746Hp/(VAX), where X = 1 if 1 Ph, and 1.73 if 3 Ph T1 - T3 (3 Ph only) F.L.A.ACTUAL T2 (3 Ph only) T3 (3 Ph only) TOTAL CFM - FAN DISCHARGE OUTSIDE AIR CFM TOTAL TOTAL CFM - OUTLETS RETURN AIR CFM INLET T1 T1 - T2 T2 - T3 (3 Ph only) REMARKS: NOM EFFY CALCULATED (P.F. x NOM EFFY) * MOTOR SHEAVE STARTER HEATER ELEMENTS BELTS FAN SHEAVE STYLE FRAME FAN RPM SHEAVE cL DISTANCE TEST DATA P.F. SERIAL NUMBER: RPM 6/16/2023 208 60 6.8 2.38 209 7.0 6.8 6.9 0.50 1.37 208 208 210 100 196 NL 0.53 NL -0.84 2700 - 3000 3096 2900 2758 DESIGN ACTUAL DESIGN ACTUAL NL - - Direct Drive Direct Drive Direct Drive Direct Drive 7.0 1.10 NL NL 0.72 -NL 2300W 1620 3 AIR MOVEMENT EQUIPMENT TEST SHEET PROJECT:Immunotek TESTED BY:N. Mailly DATE: RTU-5 Roof Coferance / Break Room / Shipping Trane YHC092F3RHA29G7C1A1A 224014392L 6/16/2023 Ebmpapst Page 7 Northeastern Air Quality, Inc. FAN TEST REPORT P.O. Box 3271, Albany, NY 12203-0271 (518) 857-3641 PROJECT: TESTED BY:DATE: MAKE: MOTOR STYLE/FRAME:-NL -NL NAME-HP/RPM:0.10 1750 0.10 1750 PLATE VOLTS: DATA PHASE/HERTZ:1 60 1 60 FL AMPS/SF:1.4 NL 1.4 NL P.F./NOM EFFY NL NL NL NL DES ACT DES ACT DES ACT DES ACT 300 -300 - 300 323 300 294 ---- EXT.DISCHARGE NL -NL - STATIC INLET NL -NL - PRESS.TOTAL ---- VOLTS T1-T2 115 121 115 121 T2-T3 (3 Ph only)-- T3-T1 (3 Ph only)-- AMPS T1 1.4 0.6 1.4 0.3 T2 (3 Ph only)-- T3 (3 Ph only)-- BHP(calc)F.L./ACTUAL 0.07 0.04 Roof EF-2EF-1FAN NUMBER: LOCATION: SERVICE: calc (P.F. x NOM EFFY) * DATE TESTED: SERIAL NUMBER: MODEL: Immunotek Vari-Green Roof 6/16/23N. Mailly UNI Greenheck Bathrooms Greenheck G-090-VG-1-17-X 6/16/2023 22123061 115 Vari-Green 22123048 6/16/2023 Direct Drive Direct Drive BELTS:Direct Drive Direct Drive 0.72 Direct Drive 0.72 MANUFACTURER: TOTAL CFM-FAN TOTAL CFM-OUTLETS FAN RPM 115 Speed set to 5/10 Speed set to 6/10 Direct Drive Direct Drive Direct Drive REMARKS: * NOTE: If P.F. or NOM EFFY are NL, (P.F. x NOM EFFY) = 746Hp/(VAX), where X = 1 if 1 Ph, and 1.73 if 3 Ph FAN SHEAVE: MOTOR SHEAVE: G-090-VG-1-17-X TEST DATA SHEAVE cL DISTANCE: Page 8 Northeastern Air Quality, Inc.GRILLE, REGISTER & DIFFUSER REPORT P.O. Box 3271, Albany, NY 12203-0271 PROJECT: (518) 857-3641 TESTED BY:DATE: REMARKS: DESIGN INITIAL INTERMEDIATE FINAL % OF NO.Location MODEL Ak VEL CFM VEL CFM VEL CFM VEL CFM DES DATE REMARKS RTU-1 1 Conference Room 24'' x 24''C 200 Hood 201 Hood 233 Hood 187 94%6/16/23 2 Training 24'' x 24''C 250 Hood 199 Hood 231 Hood 240 96%6/16/23 3 Exam Room 24'' x 24''B 100 Hood 36 Hood 52 Hood 98 98%6/16/23 4 Exam Room 24'' x 24''B 100 Hood 77 Hood 93 Hood 95 95%6/16/23 5 Exam Room 24'' x 24''B 100 Hood 76 Hood 82 Hood 96 96%6/16/23 6 Hallway 24'' x 24''B 150 Hood 144 Hood 168 Hood 147 98%6/16/23 7 Women 24'' x 24''B 100 Hood 56 Hood 76 Hood 101 101%6/16/23 8 Leadership Hub 24'' x 24''C 250 Hood 219 Hood 254 Hood 243 97%6/16/23 9 Men 24'' x 24''B 100 Hood 55 Hood 76 Hood 98 98%6/16/23 10 Vestibule 24'' x 24''A 100 Hood 81 Hood 94 Hood 92 92%6/16/23 11 Reception 24'' x 24''C 225 Hood 205 Hood 238 Hood 239 106%6/16/23 12 Kiosks 24'' x 24''C 225 Hood 210 Hood 244 Hood 245 109%6/16/23 13 Reception 24'' x 24''C 225 Hood 218 Hood 253 Hood 225 100%6/16/23 14 Kiosks 24'' x 24''C 225 Hood 140 Hood 162 Hood 207 92%6/16/23 15 Screening 24'' x 24''C 225 Hood 136 Hood 158 Hood 208 92%6/16/23 16 Screening 24'' x 24''C 225 Hood 205 Hood 229 Hood 242 108%6/16/23 17 Screening 24'' x 24''C 225 Hood 176 Hood 205 Hood 218 97%6/16/23 Total 3,025 2,981 99%6/16/23 Return 18 Screening 24'' x 24''E 1,413 Hood 1,231 87%6/16/23 19 Screening 24'' x 24''E 1,413 Hood 1,122 79%6/16/23 Total 2,825 2,353 83%6/16/23 N. Mailly 6/23/2023 Immunotek Duct Size Page 9 Northeastern Air Quality, Inc.GRILLE, REGISTER & DIFFUSER REPORT P.O. Box 3271, Albany, NY 12203-0271 PROJECT: (518) 857-3641 TESTED BY:DATE: REMARKS: DESIGN INITIAL INTERMEDIATE FINAL % OF NO.Location MODEL Ak VEL CFM VEL CFM VEL CFM VEL CFM DES DATE REMARKS N. Mailly 6/23/2023 Immunotek Duct Size RTU-2 20 Donor Floor 24'' x 24''C 300 Hood 225 Hood 300 Hood 300 100%6/16/23 21 Donor Floor 24'' x 24''C 300 Hood 212 Hood 282 Hood 282 94%6/16/23 22 Donor Floor 24'' x 24''C 300 Hood 219 Hood 291 Hood 291 97%6/16/23 23 Donor Floor 24'' x 24''C 300 Hood 228 Hood 303 Hood 303 101%6/16/23 24 Donor Floor 24'' x 24''C 300 Hood 174 Hood 280 Hood 280 93%6/16/23 25 Donor Floor 24'' x 24''C 300 Hood 205 Hood 273 Hood 273 91%6/16/23 26 Donor Floor 24'' x 24''C 300 Hood 58 Hood 273 Hood 273 91%6/16/23 27 Repair 24'' x 24''B 150 Hood 123 Hood 174 Hood 174 116%6/16/23 28 Management 24'' x 24''C 250 Hood 195 Hood 259 Hood 259 104%6/16/23 29 Donor Floor 24'' x 24''C 300 Hood 203 Hood 270 Hood 270 90%6/16/23 30 Donor Floor 24'' x 24''C 300 Hood 223 Hood 297 Hood 297 99%6/16/23 31 Donor Floor 24'' x 24''C 300 Hood 205 Hood 84 Hood 84 28%6/16/23 Total 3,400 3,086 91%6/16/23 Return 32 Donor Floor 24'' x 24''E 1,500 Hood 1,487 99%6/16/23 33 Donor Floor 24'' x 24''E 1,500 Hood 1,521 101%6/16/23 Total 3,000 3,008 100%6/16/23 RTU-3 34 Vestibule 24'' x 24''A 100 Hood 45 Hood 100 Hood 100 100%6/16/23 35 Donor Floor 24'' x 24''C 310 Hood 298 Hood 327 105%6/16/23 36 Donor Floor 24'' x 24''C 310 Hood 304 Hood 296 95%6/16/23 37 Donor Floor 24'' x 24''C 310 Hood 298 Hood 302 97%6/16/23 38 Donor Floor 24'' x 24''C 310 Hood 341 Hood 330 Hood 289 93%6/16/23 39 Donor Floor 24'' x 24''C 310 Hood 246 Hood 280 90%6/16/23 Page 10 Northeastern Air Quality, Inc.GRILLE, REGISTER & DIFFUSER REPORT P.O. Box 3271, Albany, NY 12203-0271 PROJECT: (518) 857-3641 TESTED BY:DATE: REMARKS: DESIGN INITIAL INTERMEDIATE FINAL % OF NO.Location MODEL Ak VEL CFM VEL CFM VEL CFM VEL CFM DES DATE REMARKS N. Mailly 6/23/2023 Immunotek Duct Size 40 Donor Floor 24'' x 24''C 310 Hood 267 Hood 290 94%6/16/23 41 Donor Floor 24'' x 24''C 310 Hood 100 Hood 280 Hood 280 90%6/16/23 42 Donor Floor 24'' x 24''C 310 Hood 382 Hood 278 Hood 300 97%6/16/23 43 Donor Floor 24'' x 24''C 310 Hood 352 Hood 298 Hood 292 94%6/16/23 44 Donor Floor 24'' x 24''C 310 Hood 414 Hood 264 Hood 280 90%6/16/23 Total 3,200 3,036 95%6/16/23 Return 45 Donor Floor 24'' x 24''E 1,400 Hood 1,526 109%6/16/23 46 Donor Floor 24'' x 24''E 1,400 Hood 1,430 102%6/16/23 Total 2,800 2,956 106%6/16/23 RTU-4 47 Sterile Supplies 24'' x 24''C 200 Hood 192 Hood 211 106%6/16/23 48 Sterile Supplies 24'' x 24''C 200 Hood 161 Hood 181 91%6/16/23 49 Sterile Supplies 24'' x 24''C 200 Hood 157 Hood 183 92%6/16/23 50 Sterile Supplies 24'' x 24''C 200 Hood 180 Hood 198 99%6/16/23 51 Sterile Supplies 24'' x 24''C 200 Hood 185 Hood 204 102%6/16/23 52 Sterile Supplies 24'' x 24''C 200 Hood 206 Hood 220 110%6/16/23 Total 1,200 1,197 100%6/16/23 Return 53 Sterile Supplies 24'' x 24''E 550 Hood 306 Hood 521 95%6/16/23 53.5 Sterile Supplies 24'' x 24''E 550 Hood 316 Hood 562 102%6/16/23 Total 1,100 1,083 98%6/16/23 RTU-5 Page 11 Northeastern Air Quality, Inc.GRILLE, REGISTER & DIFFUSER REPORT P.O. Box 3271, Albany, NY 12203-0271 PROJECT: (518) 857-3641 TESTED BY:DATE: REMARKS: DESIGN INITIAL INTERMEDIATE FINAL % OF NO.Location MODEL Ak VEL CFM VEL CFM VEL CFM VEL CFM DES DATE REMARKS N. Mailly 6/23/2023 Immunotek Duct Size 54 Supplies 24'' x 24''B 100 Hood 110 Hood 70 Hood 98 98%6/23/23 55 Plasma Process 24'' x 24''C 200 Hood 203 Hood 155 Hood 217 109%6/23/23 56 Shipping 24'' x 24''C 200 Hood 192 Hood 163 Hood 220 110%6/23/23 57 Employee Hall 24'' x 24''C 250 Hood 182 Hood 184 Hood 266 106%6/23/23 58 Break Room 24'' x 24''C 250 Hood 219 Hood 190 Hood 275 110%6/23/23 59 Employee Hall 24'' x 24''C 250 Hood 164 Hood 150 Hood 231 92%6/23/23 60 Break Room 24'' x 24''C 250 Hood 145 Hood 140 Hood 225 90%6/23/23 61 Janitor 24'' x 24''C 75 Hood 43 Hood 32 Hood 68 91%6/23/23 62 Employee Hall 24'' x 24''C 250 Hood 200 Hood 190 Hood 276 110%6/23/23 63 Loading / Receiving 24'' x 24''C 300 Hood 190 Hood 225 Hood 315 105%6/23/23 64 UNI 24'' x 24''A 75 Hood 90 Hood 56 Hood 78 105%6/23/23 65 UNI 24'' x 24''A 75 Hood 89 Hood 55 Hood 77 103%6/23/23 66 UNI 24'' x 24''B 150 Hood 172 Hood 110 Hood 154 103%6/23/23 67 UNI 24'' x 24''A 75 Hood 89 Hood 57 Hood 80 106%6/23/23 68 Loading / Receiving 24'' x 24''C 300 Hood 324 Hood 225 Hood 317 106%6/23/23 69 Loading / Receiving 24'' x 24''C 200 Hood 205 Hood 142 Hood 199 99%6/23/23 Total 3,000 3,096 103%6/23/23 Return 70 Loading / Receiving 24'' x 24''E 1,450 Hood 1,265 Hood 1,392 96%6/23/23 71 Loading / Receiving 24'' x 24''E 1,450 Hood 1,242 Hood 1,366 94%6/23/23 Total 2,900 2,758 95%6/23/23 Page 12 Northeastern Air Quality, Inc.GRILLE, REGISTER & DIFFUSER REPORT P.O. Box 3271, Albany, NY 12203-0271 PROJECT: (518) 857-3641 TESTED BY:DATE: REMARKS: DESIGN INITIAL INTERMEDIATE FINAL % OF NO.Location MODEL Ak VEL CFM VEL CFM VEL CFM VEL CFM DES DATE REMARKS N. Mailly 6/23/2023 Immunotek Duct Size EF-1 72 Women 24'' x 24''L 150 Hood 158 Hood 158 105%6/16/23 73 Men 24'' x 24''L 150 Hood 165 Hood 165 110%6/16/23 Total 300 323 108%6/16/23 EF-2 74 UNI 24'' x 24''L 100 Hood 152 Hood 106 106%6/16/23 75 UNI 24'' x 24''L 100 Hood 122 Hood 90 90%6/16/23 76 UNI 24'' x 24''L 100 Hood 140 Hood 98 98%6/16/23 Total 300 294 98%6/16/23 EF-3 77 Janitor 12" x 12"100 Hood 0 Hood 98 98%6/23/23 Page 13 Northeastern Air Quality, Inc.MINIMUM OUTSIDE AIR REPORT P.O. Box 3271, Albany, NY 12203-0271 PROJECT: (518) 857-3641 DATE: System Area % OF NO.Zone or Branch Sq. Ft.VEL CFM VEL CFM SP VEL CFM SP DES DATE T-1 RTU-1 36''x 16''4.00 50 200 225 900 -98 392 -196%6/23/23 T-2 RTU-2 36''x 16''4.00 100 400 281 1,124 -201 804 -201%6/23/23 T-3 RTU-3 36''x 16''4.00 100 400 217 868 -108 432 -108%6/23/23 T-4 RTU-4 27''x 11''2.06 48 100 102 210 -49 101 -101%6/23/23 T-5 RTU-5 36''x 16''4.00 25 100 349 1,396 -49 196 -196%6/23/23 Immunotek 6/16/2023 Duct Size DESIGN REQUIRMENT INITIAL FINAL Page 14 SYSTEM DIAGRAM Immunotek Page 15