Loading...
SEP-0056-2023 "�. SEPTIC DISPOSAL PERMIT office use only APPLICATION Permit#: Town of(Zeensbury Permit Fee:$ e)�5' D. � �`� i�� I� ��t,� !� v ice#: �J�lrj 742 Bay Road,Queensbury,NY 12804 ^°^-a------ P:518-761-8256 www.aueensburv.net ^M1M'o p`tic Variance? Y 409 I d Zone? Y TOVVN OF QUEE;NSBUR(w lands? _Y � Iteviewp, i:711VG&CODES Project Location: 365Cleverda&--Wc'L—"" r ) Tax Map#: 226.12-1-54FEB 0 93 RESIDENCE INFORMATION: i�;\NH OF OUELi"qSBUR1' Year Built Gallons #of bedrooms: X gallons per =total daily flow i�Uli-f DING l ---. . z-2 per day bedroom d Garbage Grinder~ Yes No 1980 or older 150 Installed? (choose one) ❑ ❑✓ 1981-1991 130 Spa or Hot Tub Yes No 1992-Present 110 5 110 550 Installed? (choose one) ❑ [�l PARCEL INFORMATION: Topography Q Flat Rolling ❑Steep Slope % Slope Soil Nature Sand [ Loam ❑ Clay ❑ Other, explain: Groundwater At what depth? >72" Bedrock/Impervious material At what depth? >72" Domestic Water Supply ❑ Municipal ❑Well OLake (if well or lake, water supply from any septic system'absorption is ft.) Percolation Test Rate: 7:20 per minute per inch (test to be completed by a licensed engineer/architect) PROPOSED SYSTEM INFORMATION: Tank size 1.500 gallons (min. size 1,000 gallons, add 250 gallons for each garbage cylinder or spa/hot tub System Absorption field w/#2 stone Total length ft.; Each Trench ft. Seepage Pit w/#3 stone How many: ; Size: Alternative System Bed or other type: 15X46 Stone Absorption Bed Holding Tank System Total required capacity? ; tank size #of tanks Septic Application Revised April 2021 CONTACT INFORMATION: PLEASE PRINT LEGIBLY OR TYPE, PLEASE INCLUDE AN EMAIL • Applicant: Name(s): John Mason for Richard O. Mead Revocable Trust Mailing Address, C/S/Z: Sunsoval. Inc. 2574 Route 9L P.O. Box 86 Cleverdale NY 12820 Cell Phone: Land Line: 518-656-9956 Email: sunsoval@gmail.com • Primary Owner(s): Name(s): Richard O. Mead Revocable Trust Mailing Address, C/S/Z: 80 Country Colony Drive Queensbury, NY 12804 Cell Phone: Land Line: Email: ❑ Check if all work will be performed by property owner only • Contractor: Contact Name(s): Crandall Excavating Contractor Trade: Excavation Mailing Address, C/S/Z: 63 Woodchuck Hill Road, Lake George, NY 12845 Cell Phone: 518.470.4694 Land Line: Email: "Workers' Comp documentation must be submitted with this application" • Eneineer(s)• Name(s): Hutchins Engineering PLLC Mailing Address, C/S/Z: 169 Haviland Road QueensburV, NY 12804 Cell Phone: Land Line: 518-745-0307 Email: _thutchins@hutchinsengineering.com Contact Person for Compliance in regards to this project:_Tom Hutchins. P.E. Cell Phone: Land Line: 518-745-0307 Email: thutchins@hutchinsenaineering.com NOTES: 1. Alarm system and associated electrical work must be inspected by a Town approved electrical inspection agency; 2. We will no longer allow systems to be covered until such time as an as-built plan is received and approved. The installed system must match the septic layout on file—no exceptions. 3. As- built drawings must be submitted prior to the inspection, if there has been a change to the submitted plans. 4. If, for any reason, the building permit application is withdrawn, 30% of the fee is retained by the Town of Queensbury. After 1 year from the initial application date, 100% of the fee is retained. Declaration: Any permit or approval granted which is based upon or is granted in reliance upon any material representation or failure to make a material fact or circumstance known by or on behalf of an applicant,shall be void. I have read the regulations and agree to abide by these and all requirements of the Town of Queensbury Sanitary Sewage Disposal Ordinance. PRINT NAME: John A. Mason SIGNATURE: -` DATE: 1/16/2023 Septic Application Revised April 2021 TOWN OF QUEENSBURY 742 Bay Road, Queensbuq, NY. 12804-5902 Septic System Checklist Plan to scale beceived Deep hole perc.test results from engineer/Architect if applicable(Town Approved Engineers and Architects,June 30 to April 15 Town Engineer for unapproved Engineers and Architects) KIGAII wells on property and adjacent properties shown— waterline shown Municipal or well 10'separation to any part of system 66etback to property lines show 10'or more for any part of system 1(—<�eptic tank and pump stations 10'from foundation 50'from any well/lake/wetland 10'from any waterline A+Septic tank to foundation crawl space/slab on grade,grade in crawl space must be above top of septic tank for 0',Separation required(field verification required) IP'ieptic tank sized for number of bedrooms and add 250 gals for Jacuzzi tubs/garbage grinder each %Leech Field 20'from foundation 100'from any well 10' from water line Seepage pit 150'from well 50'from septic tank Seepage Pits 3-times diameter apart 'Septic tank and pump stations over 30 gallons 50'from watercours�,or_wetland `distance from bottom of trench or system 24"to bedrock or mottli g 36"wit in 1000'of Lake George Leech field 100'from watercourse or wetland AA*Toe of mound or bottom of retaining wall 10'from property line 100'from well 20'from Foundation ft"'Trovide Engineer/Architect stamp for bed or design systems Department of Health Approval for all mobile home park new systems Flood Plain requirements 2'above established flood elevation to bottom of system J All tanks anchored or 2' above flood elevation DPtrioPA d/1 VX 71 O" Oak o 15" Hem ock C >>>) l I I I O" Pine /a-, . I / ov ra te-VJalk E---i: L-,..—J �,00 o - ) l I I f --�-� 1178. 23' N P9°29'10" W O / Lake Georg* I " Hemlock \ 1 krea BM Top of Nail in 40" stump 1 778 7. $q, F�et Elev.= I09.44' � 0.411 Acres ' I y SEP71C TANK TO BE DECOMMISSIONED. INTERIOR G TO BE RE-ROUTED TO NORTH SIDE BUILDING EXISTING WASTEWATER SYSTEM PLAN SCALE: 1 "=20' GRAPHIC SCALE 10 0 5 10 20 40 ( IN FEET ) CONTRACTOR TO FIELD VERIFY LOCATIONS AND DISTANCES RECORD DRAWING NOTE: SEPTIC TANK AND PUMP STATION RISERS /NSTAI APPROXIMATELY 6" BELOW FINISHED GRADE. PROXIMATE DIMENSION TABLE FOR LOCATIONS _ ISH GRADE 4" PVC INLET MIN. SLOPE 1/8" PER FOOT WATERTIGHT SLEEVE - AND SEAL (TYP) 1,500 GAL PRECAST CONCRETE SEPTIC TANK Crushed Stone Lands N/F of Mary Mattson B:1014 P:111 I 226. 12-1-53 U.P. NM4 LAKE WATER SUPPLY I WASTEWATER SYSTEM SETBACK REQUIREMENTS PROPERTY LINE HOUSE STREAM, LAKE, WATERCOURSE, WE7L4ND WELL SEP71C TANK 10' 10' 50' 50' ABSORP77ON FIELD 1 10' 20' 1 100' 100' POLYETHYLENE EXTENSION TO GRADE WITH TAMPER RESISTANT ACCESS COVER 12" MIN. COVER 1/8" PER FOOT j r 2" MIN. SLOPE LIQUID LEVEL DUAL COMPARTMENT. 18" 16" BAFFLE MIN. CLzx o g g - nl M <. 1. MINIMUM 2X WIDTH I MAXIMUM 4X WIDTH OUTLET 4" PVC °. e.° Ga .< ° a 8. SEPTIC TANK NOTES ALL UNITS SHALL COMPLY KITH THE REQUIREMENTS OF THE NEW YORK STATE DEPARTMENT OF HEALTH AND SHALL BE OF PRECAST CONCRETE AS MANUFACTURED BY UTOPIA ENTERPRISES OR EQUIVALENT ALL STRUCTURES SHALL BE PLACED ON FIRM, COMPACT SAND OR GRAVEL BASE. WHERE EXISTING SOIL CONDITIONS ARE UNSUITABLE, CRUSHED STONE SHALL BE PLACED AS NECESSARY TO ACHIEVE A STABLE BASE. SEPTIC TANKS INSTALLED IN TRAFFIC AREAS SHALL BE OF EXTRA HEAVY CONSTRUC77ON DESIGNED FOR H-20 WHEEL LOADING. ALL JOINTS MUST BE SEALED WITH BUTYL SEALANT. JOINTS BELOW THE LIQUID LEVEL MUST BE TESTED BEFORE BACKFILLING. ALARM 3" ABOVE 'PUMP ON' & LAG PUMP ON PUMP ON PUMP OFF POLYETHYLENE EXTENSION TO GRADE WITH TAMPER RESISTANT ACCESS COVER INSTALL FLOAT SWITCHES TO OPERATE PUMP AND MAINTAIN LEVELS AS INDICATED BALL VALVE T BALL CHECK VALVE FLOAT SWITCHES ° -INSTALL INSIDE PUMP PIT IN LOCA77ON ACCESSIBLE M774OUT PIT ENTRY DUPLEX 16" MIN. EFFLUENT PUMPS 4 ° ° a G d RECORD DRAWING DIMENSIONS TABLE CORNER "A" CORNER "B" S. T. INLET PORT 18.67' 25' S T. OUTLET PORT 22.5' 21.3' PUMP STATION PORT 25.8' 19' DIS7R1BU1TON BOX 36.5' 21 ' 1,000 GALLON PRECAST CONCRETE PUMP STATION SEPTIC TANK & PUMP STATION DETAIL SCALE. NTS 4" TOPSOIL COVER ABOVE 4" PVC PERFORATED LATERAL __\FILTER FABRIC TOP OF STONE BED, INSTALLED LEVEL, IN BED MIRAFI 140N OR EQUAL SEED & ESTABLISH TURF CONFICURA77ON WITH MANIFOLDED ENDS 5' PIPE SPACING 2.5' TO EDGE OF BED 8-16" - COVER .:: :..,. ..... ..... 2 STONE TO TA C01/ER OVER - P•. , STONE DEP1N PIPE . �., = / ._; r ;, . y:®'�° .r:...? .: �:.. BOTTOM OF STONE EL. 102.5 .. .: - ,r._. - 6" MIN STONE `.: BELOW PIPE _ __ BED WIDTH & GEOMETRY PER PLAN3' MINIMUM SEPARATION ... T 0 BOUNDARY ... CONDITION 3/4"-1-1/2" WASHED CRUSHED STONE A l 1/'•/1 A P1TT/ 0 A ! ^ rr1 nri+-rr^ n SCALE. NTS LIMIT or r' . S7 15' PROVIDE 5' FROST PROTEC77ON � 4r Al l C n -F PROPOSED WASTEWATER SYSTEM PLAN SCALE: 1 "=20' GRAPHIC SCALE i I 10 0 5 10 20 40 ( IN FEET ) I CONTRACTOR TO FIELD VERIFY LOCA77ONS AND DISTANCES EXTERIOR WEATHERPROOF JUNCTION BOX (IF NECESSARY). SEAL CONDUIT GAS TIGHT. INSTALL CONTROL PANEL IN HOUSE. ALL ELECTRICAL WORK TO BE INSPECTED BY A CER71FIED ELECTRICAL INSPECTION AGENCY PRIOR TO START-UP OF PUMP STATION. 12" MIN. COVER DISTRIBUTION BOX L 2" MIN. 2" MIN. DROP BETWEEN INVERTS PUMP STATION NOTES SEAL ALL TANK OPENINGS W47ER11GHT. PROVIDE AND INSTALL UL LISTED PACKAGED PUMP CONTROL PANEL WITH VISUAL AND AUDIBLE ALARM. 1-1 2" SCH-40 PVC PIPING INSTALL SIMPLEX, DEMAND DOSE CONTROL PANEL INSIDE WET WELL THROUGH WALL INSIDE HOUSE IN ACCESSIBLE LOCATION. INSTALL POWER & CONTROL WIRING TO CONTROLLER UNION - LOCATE SUCH THAT WITH ALARM IN HOUSE IN ACCORDANCE WITH UNION CAN BE DISCONNECTED AND MANUFACTURER'S INSTRUCTIONS AND NA77ONAL PUMP REMOVED WITHOUT TANK ELECTRIC CODE (N.E.G) REQUIREMENTS. ENTRY PUMP CONTROL AND FLOAT LEVELS TO BE INSTALLED REDUCING TEE POINTED DOWNWARD TO PROVIDE A 50 GALLON DOSE. WITH 1 " BALL VALVE THROTTLED TO ALLOW TRICKLE DRAIN BACK INTO EFFLUENT PUMPS TO BE GOULDS PUMPS WE SERIES, MODEL WEO3L SUBMERSIBLE EFFLUENT PUMP 1/3 HP, WETWELL 230 VOLT, 1PH VERIFY EXISTING ELECTRICAL SERVICE PRIOR TO PURCHASING PUMP. ALL ELECTRICAL WORK TO BE INSPECTED BY A CER77FIED ELECTRICAL INSPECTION AGENCY PRIOR TO START-UP OF PUMP ST4770N. 46' ' ABSORPTION BED PROFILE SCALE. NTS co Or U 4 u,LU a �w co fE W C/) t— Y J Lands N/F of Mary Mattson B:1014 P:111 226.12-1-53 LAKE WATER SUPPLY WASTEWATER SYSTEM DESIGN 5-BEDROOM RESIDENCE DESIGN FLOW - 110 GPD/BEDROOM SYSTEM DESIGN FLOW - 550 GPD SEP71C TANK - NEW 1,500 GALLON PRECAST CONCRETE PUMP STATION - NEW 1,000 GALLON PRECAST CONCRETE DESIGN APPLICATION RATE: 0.8 GPD/SF, BASED ON 6-7 MIN/IN PERCOLA77ON RATE ABSORP71ON BED AREA REWD = (550 GPD)/(0.8 GPD/SF) = 688 SF AB E77QU BED AREA PROVIDED = 15 z46' = 690 SF POTABLE WATER SUPPLY IS LAKE GEORGE MAINTAIN 10' MINIMUM SEPARA7ON BETWEEN WATER SUPPLY LINE(S) AND ALL WASTEWATER SYSTEM COMPONENTS SITE SOILS DATA TEST PIT TP-1 - 121912022 BY TOM HUTCHINS, P.E. GRADE EL. 105.3' 0-4" - WOODS DUFF/TOPSOIL 4-20" - LIGHT BROWN FINE SAND, LITTLE SILT 20-38" - RED -BROWN LOAMY FINE SAND, VERY OLD FILL 38-72" - MEDIUM BROWN GRAVELLY SILTY FINE srTE LOCATION --J LOCATION MAP SYSTEM INSTALLATION NOTES CONSTRUCTION SHALL BE AS SHOWN ON THIS DRAWING AND IN ACCORDANCE WITH THE N.Y.S. DEPARTMENT OF HEALTH INDIVIDUAL HOUSEHOLD SYSTEMS AND ASTM F481 INSTALLATION OF THERMOPLASTIC PIPE AND CORRUGATED TUBING IN SEPTIC TANK LEACH FIELDS. AFTER EXCAVATION OF 15' WIDE X 46' LONG ABSORPTION BED TO THE DEPTH REQUIRED, THE WALLS AND FLOOR SHALL BE CLEANED AND RAKED IN ORDER TO LOOSEN SMEARED AREAS OF SOIL. PLACEMENT OF CRUSHED STONE, PERFORATED PIPE AND FILTER FABRIC SHALL BE AS SHOWN, AND CARE SHALL BE EXERCISED TO AVOID INCLUSION OF FINE GRAINED SOILS AND WASTE MATERIAL IN THE STONE AND PIPE. THE PIPE SHOULD BE LAID AT THE GRADES INDICATED, MAINTAINING STRAIGHT CONTINUOUS GRADES WITHOUT SAGS, HUMPS, SEPARATED JOINTS, OR OTHER UNSUITABLE CONDITIONS PIPE SHALL BE LAID WITH HOLES DOWN IN ALL CASES. ALL DISPOSAL FIELDS SHALL BE GRADED TO SHED RAINFALL AND DIVERT SURFACE RUNOFF AWAY FROM THE DISPOSAL FIELD. DO NOT USE HEAVY EQUIPMENT WITHIN THE ABSORPTION AREA AFTER PIPING HAS BEEN INSTALLED. THE WASTEWATER TREATMENT SYSTEM IS DESIGNED AND APPROVED BASED UPON THE INSTALLATION OF WATER CONSERVING FIXTURES AND A DESIGN FLOW OF 110 GPD PER BEDROOM. THE SYSTEM IS NOT DESIGNED TO ACCOMMODATE EXTREME WATER USE FIXTURES, SUCH AS JACUZZI-TYPE SPA TUBS OR WATER TREATMENT EQUIPMENT. THE INSTALLATION OF NON -CONSERVING WATER FIXTURES OR EXTREME WATER USE FIXTURES IS CONTRARY TO THE APPROVAL OF 7HIS WASTEWATER TREATMENT SYSTEM. ROOF, FOOTING, GARAGE, CELLAR AND SURFACE WATER DRAINAGE MUST BE EXCLUDED FROM THE WASTEWATER SYSTEM. CONSTRUCT DRAINAGE SWALE UPGRADE OF SYSTEM IN ORDER TO DIVERT SURFACE RUNOFF AROUND ABSORPTION FIELD. SEPTIC TANK, PUMP STA77ON & ABSORPTION BED MUST BE INSPECTED BY LOCAL BUILDING DEPARTMENT AND DESIGN ENGINEER PRIOR TO BACKFILL AND FINAL GRADING. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO IDENTIFY THE NECESSARY PARTIES AND REQUEST INSPECTIONS. SYSTEM MATERIAL SPECIFICATIONS ABSORPTION FIELD AGGREGATE STONE IS TO BE 3/4" TO 1-1/2" WASHED CRUSHED STONE. EFFLUENT FILTER EFFLUENT FILTER TO HAVE 1/16-INCH FILTRATION, POLYLOK PL-122 OR EQUIVALENT. EFFLUENT SEWER PIPE PIPING TO BE 4" SDR-35 OR SCHEDULE 40 PVC. INSTALL WITH 1/8" PER FOOT MINIMUM SLOPE. FILTER FABRIC FILTER FABRIC TO BE 4.8 OZ/SY NON -WOVEN SEPARATION FABRIC, TENCATE MIRAFI 140N OR EQUIVALENT. HOUSE SEWER PIPE PIPING TO BE 4" SDR-35 OR SCHEDULE 40 PVC. INSTALL WITH 1/4" PER FOOT MINIMUM SLOPE. TOPSOIL PLACE 4" MINIMUM TOPSOIL OVER ENTIRE BACKFILL AREA. SEED, MULCH, AND ESTABLISH TURF. SAND RECORD DRAWING NOTE: A REPRESENTATIVE OF OUR OFFICE VISITED THE SITE BOTTOM OF TEST PIT EL. 99.3' DURING CONSTRUCTION AND IT IS MY OPINION THAT NO GROUNDWATER TO 72" THE SYSTEM IS INSTALLED IN GENERAL CONFORMANCE NO MOTTLING WITH THE APPROVED PLAN AND THIS RECORD ROOTS ENTIRE DEPTH DRAWING FINAL SURFACE FINISHING AND TURF ESTABLISHMENT IS ONGOING PERCOLATION TEST G. THOMAS HUTCHINS, P.E. PT-1 - 12/9/2022 BY TOM HUTCHINS, RE 6/30/2023 STABILIZED PERCOLA77ON RATE. 7.20 PER INCH RECORD DRAWING INSTALLATION DATE: 6/30/2023 ALLED BY - CRANDALL EXCAVATING INC. TAX MAP # 226.12-1-54 )POSED TIBU77ON BOX 7FSafely. RANS ON FORCE MAIN TO 4" PVC FA Dig NdwFffork OUTSIDE OF D-BOX ® Call Before You Dig 03 Wait The Required Time ® Confirm Utility Response 1 RECORD DRAWING 61301202 EM Respect The Marks Dig With Care 8®®'962'796� 0 ISSUED FOR PERMIT 1/16/202. www.d igsafelynewyork.com No. Revisions Date WASTEWATER SYSTEM PLAN DETAILS prepared for: Richard 0. Mead Revocable Trust 365 Cleverdale Road Town of Queensbury, County of Warren, State of New York MAP REFERENCE: BASE MAP INFORMATION FROM "MAP OF A TOPOGRAPHIC SURVEY MADE FOR RICHARD & MADELINE MEAD," IN THE TOWN OF QUEENSBURY, WARREN COUNTY, NEW YORK. DATED APRIL 12, 2022. PREPARED BY. n D us e & S t e V@ S LOLild S1.1Y'VeyO3r8 169 Haviland Road Queensbury, New York 12804 (518) 792-8474 New York Lie. No. 50135 0E ��" p PS Q �� U_ I �- ;:, L w $ ' ? `� p 067 i� r 10 0 O ALTERATION OF THIS XCEPT BY A LICENSED PROFESSION ' ENGINEER IS A VIOLATION OF NYS EDUCATION LAW. Drawn: JRS Checked: GTH Scale: NOTED Date: 51212022 169 Haviland Road Queensbury, NY 12804 (518) 745-0307 Phone Hutchins Engineering PLLC (518) 745-0308 Fax 291967-01