Loading...
SEP-0350-2023 SEPTIC DISPOSAL PERMIT Office Use Only APPL -...�. Permit#: � -O��- Zo 2 25 Town ofQueensbury rmlt Fee:$ JUN 1 6 2023 1 voice#: E22- 742 Bay Road,Queensbury,NY 12804 P:518-761-8256 www.gueensbury.net TO epticVariance``LJ OF OGEE BUILDING& COI)E'S lood zone? Wetlands? fJ-0 Reviewed By: Project Location: 24 Island View Drive t Tax Map #: 309.18-1- RESIDENCE INFORMATION: Year Built Gallons #of bedrooms: X gallons per =total daily flow per day bedroom Garbage Grinder Yes No 1980 or older 150 Installed? (choose one) Q ❑ 1981-1991 130 Spa or Hot Tub Yes No 1992-Present 110 3 110 330 Installed? (choose one) ❑ o PARCEL INFORMATION: Topography Flat Rolling ❑ Steep Slope % Slope Soil Nature 0 Sand ❑ Loam ❑ Clay ❑ Other, explain: Groundwater At what depth? >82" Bedrock/Impervious material At what depth? >82" Domestic Water Supply ❑ Municipal 0 Well ❑Lake (-if well or lake, water supply from any septic system absorption is 105 ft.) Percolation Test Rate: 1:50 per minute per inch (test to be completed by a licensed engineer/architect) PROPOSED SYSTEM INFORMATION: Tank size 1.000 gallons (min. size 1,000 gallons, add 250 gallons for each garbage cylinder or spa/hot tub existing 1,000 gallon concrete System Absorption field w/#2 stone Total length ft.; Each Trench ft. Seepage Pit w/#3 stone How many: ; Size: Alternative System Bed or other type: 15' x 30' pipe-in-stone absorption bed Holding Tank System Total required capacity? ; tank size ; # of tanks Septic Application Revised July 2022 CONTACT INFORMATION: PLEASE PRINT LEGIBLY OR TYPE, PLEASE INCLUDE AN EMAIL • Applicant: Name(s): David Cook Mailing Address, C/S/Z: 24 Island View Dr.,Queensburj,NY,12804 Cell Phone: Land Line' Email: modmel@hotmail.com • Primary Owner(s): Name(s): David Cook, Vicky Cook Mailing Address, C/S/Z: 24 Island View Dr.,Queensbury NY 12804 Y Cell Phone: 518-681-6261 Land Line: Email: modmel@hotmail.com ❑Check if all work will be performed by property owner on iv • Contractor: Contact Name(s): Daigle Construction Contractor Trade: Construction &excavating Mailing Address, C/S/Z: 19 Boulevard Queensbury, NY 12804 Cell Phone: 518-796-6521 Land Line: Email: daiglenick@yahoo.com "Workers' Comp documentation must be submitted with this application" • Engineer(s): Name(s): Hutchins Engineering PLLC Mailing Address, C/S/Z: 169 Haviland Road Queensbury, NY 12804 Cell Phone: Land Line: 518-745-0307 Email: thutchins@hutchinsen ineering.com Contact Person for Compliance in regards to this project: David Cook Cell Phone: Land Line: 518 79 35 7 B Email: modmel@hotmail.com Declaration: Any permit or approval granted which is based upon or is granted in reliance upon any material representation or failure to make a material fact or circumstance known by or on behalf of an applicant, shall be void. I have read the regulations and agree to abide by these and all requirements of the Town of Queensbury Sanitary Sewage Disposal Ordinance. PRINT NAME: David Cook SIGNATURE:, DATE: 5/16/23 Septic Application Revised July 2022 (awTOWN OF QUEENSBURY 742 Bay Road, Queensbury, NY. 12804-5902 Septic System Checklist elan to scale 4 Received Deep hole perc test results from engineer/Architect if applicable(Town Approved Engineers and Architects;June 30 to April 15 Town Engineer for unapproved Engineers and Architects) q-6All wells on property and adjacent properties shown eater line shown Municipal or well 10'separation to any part of system 'Setback to property lines show 10'or more for any part of system 2 Septic tank and pump stations 10'from foundation, 50'from any well/lake/wetland, 10'from any waterline /J418c� eptic tank to foundation crawl space/slab on grade,grade in crawl space must be above top of septic tank for 0',Separation required (field verification required) �q5ASeptic.tank sized for number of bedrooms and add 250 gals for Jacuzzi tubs/garbage grinder each Iff�iLeech Field 20'from foundation 100'from any well 10'from water line &�44Seepage pit 150'from well 50'from septic tank �4k5eepage Pits 3-times diameter apart Septic tank and pump stations over 30 gallons 50'from watercourse or wetland Distance from bottom of trench or system to bedrock or mottling 36" within 1000'of Lake George C''P` eech field 100'from watercourse or wetland NbToe of mound or bottom of retaining wall 10'from property line, 100'from well,20'from foundation � Provide Engineer/Architect stamp f Department of Health Approval for all mobile home park new systems Flood Plain requirements 2'above established flood elevation to bottom of system All tanks anchored or 2' above flood elevation LANDS N/F OF EVELYN R. CARROL PARCEL VACANT NO WELL b / I � \ E E E E -40,k APPROXIMATELY 180' TO LANDS N/F OF` NEIGHBORING WELL / KWW RAE ERNST / / WASTEWATER SYSTEM PLAN SCALE: 1 "=20' GRAPHIC SCALE 10 0 5 10 20 40 ( IN FEET ) CONTRACTOR TO FIELD VERIFY LOCATIONS AND DISTANCES THIS IS NOT A FIELD SURVEY. 4" TOPSOIL COVER ABOVE TOP OF STONE BED, SEED & ESTABLISH TURF r 4" PVC PERFORATED LATERAL INSTALLED LEVEL, IN BED CONFIGURATION 107H MANIFOLDED ENDS 8-16" COVER _ — 3/4"-1-1/2" WASHED CRUSHED STONE i i i EXISTING/ WELL] / HUDSON RIVER FILTER FABRIC MIRAFI 140N OR EQUAL 5' PIPE SPACING 2.5' TO EDGrET OF BED - BED WID7H & GEOMETRY PER PLAN F-11 I- .............. .._. ..._..._�40N. ABSORPTION BED SECT ION N7S 12 TOTAL STONE DEPTH I 2' MINIMUM .. . .. SEPARATION . .......... TO BOUNDARY - _..:: ........ CONDITION WASTEWATER SYSTEM DESIGN 3-BEDROOM RESIDENCE DESIGN FLOW - 110 GPD/BEDROOM SYSTEM DESIGN FLOW - 330 GPD SEPTIC TANK - EXIST. 1,000 GALLON PRECAST CONCRETE TO BE PUMPED, INSPECTED, & REUSED IF SUITABLE. INSPECT BAFFLES DESIGN APPLICATION RATE: .95 GPD/SF, BASED ON 1-5 MIN/IN PERCOLATION RATE ABSORPTION BED AREA REQ'D = (330 GPD)/(.95 GPD/SF) = 348 SF ABSORPTION BED AREA PROVIDED = 15 x30' - 450 SF POTABLE WATER SUPPLY IS TO BE WELL MAINTAIN 50' MINIMUM SEPARATION BETWEEN SEPTIC TANK & WELL MAINTAIN 100' MINIMUM SEPARATION BETWEEN ABSORPTION FIELD & WELL 4" MINIMUM TOPSOIL ON ENTIRE BACKFILL AREA; SEED AND ESTABLISH TURF 25' BED +--&awE LENGTH SITE SOILS DATA TEST PIT TP-1 - 6/13/2023 BY TOM HUTCHINS, P.E. 0-16" — TOPSOIL 16-75" — YELLOW BROWN FINE & VERY FINE SAND 75-82" — LIGHT BROWN COARSE SANDY GRAVEL DRY ALL DEPTH ROOTS 0 57" MOTTLING 0 64" BOUNDARY ® 64" PROVIDE 24" VERTICAL SEPARATION TO BOUNDARY CONDITION PERCOLATION TEST PT-1 6/13/2023 BY TOM HUTCHINS, P.E. STABILIZED PERCOLATION RATE: 1:50 PER INCH APPROXIMATE EXISTING GRADE 4" SDR-35 PVC PERFORATED ABSORPTION BED PROFILE FILTER FABRIC, TENCAIF LATERAL INSTALLED NEAR LEVEL, NIS MIRAFI 140N OR EQUIVALENT IN BED CONFIGURATION 15' LIMIT OF 15'x30' 4" PERFORATED PVC LATERALS STONE BED INSTALLED NEAR LEVEL IN /T BED CONFIGURATION 30' 4" PVC WTH GOOSENECK T ABSORPTION BED PLAN N7S DISTRIBUTION BOX 4" PVC SDR-35 OUTLET MIN. SLOPE BAFFLE 1/8" PER FOOT 2" MIN. DROP BETWEEN INVERTS 12" MAX. COVER 2" MIN. PROPOSED DISTRIBUTION BOX r 4" PVC I EFFLUENT SEWER DISTRIBUTION BOX NOTES USE SPEED LEVELERS TO • PIPE JOINTS TO BE SEALED WITH ASPHALTIC ASSURE ALL OUTLETS ARE AT MATERIAL OR EQUIVALENT. EXACTLY THE SAME ELEVATION • INVERT ELEVATIONS OF ALL OUTLET PIPES 4" PVC SDR-35 SOLID HEADER-1MUST BE EQUAL, USE SPEED LEVELERS. • D—BOX TO BE INSTALLED IN CONFORMANCE TO PERFORATED TRENCH PIPING, 1/8" PER FOOT MIN SLOPE WITH MANUFACTURER'S INSTRUCTIONS. DISTRIBUTION BOX DETAIL NIS MAP REFERENCE: BASE MAP INFORMATION FROM WARREN COUNTY GIS, AERIAL PHOTOGRAPHY, AND FIELD MEASUREMENTS. THIS IS NOT A FIELD SURVEY. ALL LOCATIONS ARE APPROXIMATE CONTRACTOR TO FIELD VERIFY ALL SETBACKS PRIOR 70 BEGINNING INSTALLATION. WASTEWATER SYSTEM SETBACK REQUIREMENTS PROPERTY LINE HOUSE STREAM, LAKE, WATERCOURSE, WETLAND WELL SEPTIC TANK 10' 10' 50' 50' ABSORPTION FIELD 10' 1 20' 1 100' 1 100' SITE LOCATION —' LOCATION MAP SYSTEM INSTALLATION NOTES CONSTRUCTION SHALL BE AS SHOWN ON THIS DRAWING AND IN ACCORDANCE WITH THE N.Y.S. DEPARTMENT OF HEALTH INDIVIDUAL HOUSEHOLD SYSTEMS AND ASTM F481 INSTALLATION OF THERMOPLASTIC PIPE AND CORRUGATED TUBING IN SEPTIC TANK LEACH FIELDS AFTER EXCAVATION OF 15' WIDE X 30' LONG ABSORP7ION BED TO THE DEPTH REQUIRED, THE WALLS AND FLOOR SHALL BE CLEANED AND RAKED IN ORDER TO LOOSEN SMEARED AREAS OF SOIL. PLACEMENT OF CRUSHED STONE, PERFORATED PIPE AND FILTER FABRIC SHALL BE AS SHOWN, AND CARE SHALL BE EXERCISED TO AVOID INCLUSION OF FINE GRAINED SOILS AND WASTE MATERIAL IN 774E STONE AND PIPE. THE PIPE SHOULD BE LAID AT THE GRADES INDICATED, MAINTAINING STRAIGHT CONTINUOUS GRADES WITHOUT SAGS, HUMPS, SEPARATED JOINTS, OR OTHER UNSUITABLE CONDITIONS PIPE SHALL BE LAID WITH HOLES DOWN IN ALL CASES. ALL DISPOSAL FIELDS SHALL BE GRADED TO SHED RAINFALL AND DIVERT SURFACE RUNOFF AWAY FROM THE DISPOSAL FIELD. DO NOT USE HEAVY EQUIPMENT WITHIN THE ABSORPTION AREA AFTER PIPING HAS BEEN INSTALLED. THE WASTEWATER TREATMENT SYSTEM IS DESIGNED AND APPROVED BASED UPON THE INSTALLATION OF WATER CONSERVING FIXTURES AND A DESIGN FLOW OF 110 CPO PER BEDROOM. THE SYSTEM IS NOT DESIGNED TO ACCOMMODATE EXTREME WATER USE FIXTURES, SUCH AS JACUZZI—TYPE SPA TUBS OR WATER TREATMENT EQUIPMENT. THE INSTALLATION OF NON —CONSERVING WATER FIXTURES OR EXTREME WATER USE FIXTURES 1S CONTRARY TO THE APPROVAL OF THIS WASTEWATER TREATMENT SYSTEM. ROOF, FOOTING, GARAGE, CELLAR AND SURFACE WATER DRAINAGE MUST BE EXCLUDED FROM THE WASTEWATER SYSTEM. CONSTRUCT DRAINAGE SCALE UPGRADE OF SYSTEM IN ORDER TO DIVERT SURFACE RUNOFF AROUND ABSORPTION FIELD. SEPTIC TANK & ABSORPTION BED MUST BE INSPECTED BY LOCAL BUILDING DEPARTMENT AND DESIGN ENGINEER PRIOR TO BACKFILL AND FINAL GRADING IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO IDENTIFY THE NECESSARY PARTIES AND REQUEST INSPECTIONS .SY(TFM MATFI?TAI SPFrTFTrATTnNS ABSORPTION FIELD AGGREGATE STONE IS TO BE 3/4" TO 1-1/2" WASHED CRUSHED STONE. EFFLUENT SEWER PIPE PIPING- TO BE 4" SDR-35 OR SCHEDULE 40 PVC. INSTALL WI7H 1/8" PER FOOT MINIMUM SLOPE. FILTER FABRIC FILTER FABRIC TO BE 4.8 OZ/SY NON —WOVEN SEPARATION FABRIC, 7ENCATE MIRAFI 140N OR EQUIVALENT. TOPSOIL PLACE 4" MINIMUM TOPSOIL OVER ENTIRE BACKFILL AREA. SEED, MULCH, AND ESTABLISH TURF. Dig rFA Safely, New/,York E Call Before You Dig ■ Wait The Required Time ■ Confirm UdI ty-Response ■ Respect The Marks N Dig V ith Care 800-962.7962 wwW.digWE nawyork.com TOWN OF QUEENSBURY BUILDING DEPARTMENT Based on our limited examination, compliance with our comments shall not be construed as indicating the plans and specifications are in full compliance with the Building Codes of New York State. FILE COPY Nsgv Epp ' CL\� �V� a TAX MAP # 309.18-1-2 LANDS N/F OF EVELYN B. CARROL PARCEL VACANT NO WELL as F5\ A a o/ \ \ E E E E 0 i i i v EXIS77NG// WELL] / APPROXIMATELY ` ® 180, TO LANDS N/F OF ` NEIGHBORING WELL KELSEY RAE ERNST ` % / / II UDSON a � / •//// RIVER O A WASTEWATER SYSTEM PLAN SCALE: 1 "=20' GRAPHIC SCALE 10 0 5 10 20 40 ( IN FEET ) CONTRACTOR TO FIELD VERIFY LOCATIONS AND DISTANCES THIS IS NOT A FIELD SURVEY. RECORD DRAWING DIMENSIONS TABLE CORNER "A" CORNER "B" S. T. INLET PORT 38.5' 29' S T. 0U77-ET PORT 43, 32' DISTRIBUTION BOXr— 48,75' -- — 2 STONE a \ 12" TOTAL . �... .:.COVER OVER ....:..; _.. STONE DEPTH 1 PIPE !�i:_ . .p r j 6" MIN STONE ---: BELOW PIPE ._ _ ... —BED WIDTH & GEOMETRY PER PLAN 2' MINIMUM ' SEPARATION TO BOUNDARY: _. _ CONDI LION 3/4" CRUSHEDWSTONE ARgnPPTTnN RFI) SFrTTnN NTS WASTEWATER SYSTEM DESIGN 3—BEDROOM RESIDENCE DESIGN FLOW — 110 GPD/BEDROOM SYSTEM DESIGN FLOW — 330 GPD SEPTIC TANK — EXIST. 1,000 GALLON PRECAST CONCRETE TO BE PUMPED, INSPECTED, & REUSED IF SUITABLE. INSPECT BAFFLES. DESIGN APPLICATION RATE: .95 GPD/SF, BASED ON 1-5 MIN/IN PERCOLATION RATE ABSORPTION BED AREA REQ'D = (330 GPD)/(.95 GPD/SF) = 348 SF ABSORPTION BED AREA PROVIDED = 15'x30' = 450 SF POTABLE WATER SUPPLY IS TO BE WELL MAINTAIN 50' MINIMUM SEPARATION BETWEEN SEPTIC TANK & WELL MAINTAIN 100' MINIMUM SEPARATION BETWEEN ABSORPTION FIELD & WELL 4" MINIMUM TOPSOIL ON ENTIRE BACKFILL AREA; SEED AND ESTABLISH TURF 25' BED LENGTH ­s�.oPE SLaPE--, 77 41'. SITE SOILS DATA TP-1 — 6113/2023 BY TOM HUTCHINS, P.E. 0-16" — TOPSOIL 16-75" — YELLOW BROWN FINE & VERY FINE SAND 75-82" — LIGHT BROWN COARSE SANDY GRAVEL DRY ALL DEPTH ROOTS ® 57" MOTTLING @ 64" BOUNDARY @ 64" PROVIDE 24" VERTICAL SEPARATI0N TO BOUNDARY CONDITION PERCOLATION TEST PT-1 — 6/13/2023 BY TOM HUTCHINS, P.E. STABILIZED PERCOLATION RATE: 1:50 PER INCH 4" SDR-35 PVC PERFORATED LATERAL INSTALLED NEAR LEVEL, IN BED CONFIGURATION LIMIT OF 15'x30' STONE BED 15' _. ABSORPTION BED PROFILE NTS 30' 4" PERFORATED PVC LATERALS INSTALLED NEAR LEVEL IN BED CONFIGURATION 4"PVC NTH GOOSENECK VENT ABSORPTION BED PLAN NTS DISTRIBUTION BOX 4" PVC SDR-35 OUTLET MIN. SLOPE BAFFLE 1/8" PER FOOT 2" MIN. DROP BETWEEN INVERTS 12" MAX. COVER 2" MIN. 5 APPROXIMATE EXISTING GRADE FILTER FABRIC, TENCATE MIRAFI 140N OR EQUIVALENT PROPOSED DISTRIBU770N BOX r 4" PVC I EFFLUENT SEWER DISTRIBUTION BOX NOTES USE SPEED LEVELERS TO • PIPE JOINTS TO BE SEALED W1714 ASPHAL71C ASSURE ALL OUTLETS ARE AT MATERIAL OR EQUIVALENT EXACTLY THE SAME ELEVATION • INVERT ELEVATIONS OF ALL OUTLET PIPES 4" PVC S110-35 SOLID HEADER MUST BE EQUAL, USE SPEED LEVELERS. TO PERFORATED TRENCH PIPING, D-BOX TO BE INSTALLED IN CONFORMANCE 1/8" PER FOOT MIN SLOPE MTH MANUFACTURER'S INSTRUCTIONS. DISTRIBUTION BOX DETAIL NTS MAP REFERENCE: BASE MAP INFORMATION FROM WARREN COUNTY GIS, AERIAL PHOTOGRAPHY, AND FIELD MEASUREMENTS. THIS IS NOT A FIELD SURVEY. ALL L0CA77ONS ARE APPROXIMATE. CONTRACTOR TO FIELD VERIFY ALL SETBACKS PRIOR TO BEGINNING INSTALLATION. WASTEWATER SYSTEM SETBACK REQUIREMENTS PROPERTY LINE HOUSE STREAM, LAKE, WATERCOURSE, WETLAND WELL SEPTIC TANK 10' 10' 50' 50' ABSORPTION FIELD 10' 20' 100' 100' Ail tQ1 hk '. b a t ., ,r SITE LOCATION I orA TT®A/ MAP SYSTEM INSTALLATION NOTES CONSTRUCTION SHALL BE AS SHOWN ON THIS DRAWING AND IN ACCORDANCE WITH THE N.Y.S. DEPARTMENT OF HEALTH INDIVIDUAL HOUSEHOLD SYSTEMS AND ASTM F481 INSTALLATION OF THERM0PLAS77C PIPE AND CORRUGATED TUBING IN SEPTIC TANK LEACH FIELDS AFTER EXCAVATION OF 15' WIDE X 30' LONG ABSORPTION BED TO THE DEPTH REQUIRED, THE WALLS AND FLOOR SHALL BE CLEANED AND RAKED IN ORDER TO LOOSEN SMEARED AREAS OF SOIL. PLACEMENT OF CRUSHED STONE, PERFORATED PIPE AND FILTER FABRIC SHALL BE AS SHOWN, AND CARE SHALL BE EXERCISED TO AVOID INCLUSION OF FINE GRAINED SOILS AND WASTE MATERIAL IN THE STONE AND PIPE. THE PIPE SHOULD BE LAID AT THE GRADES INDICATED, MAINTAINING STRAIGHT CONTINUOUS GRADES WITHOUT SAGS, HUMPS, SEPARATED JOINTS, OR OTHER UNSUITABLE CONDITIONS PIPE SHALL BE LAID WITH HOLES DOWN IN ALL CASES. ALL DISPOSAL FIELDS SHALL BE GRADED TO SHED RAINFALL AND DIVERT SURFACE RUNOFF AWAY FROM THE DISPOSAL FIELD. DO NOT USE HEAVY EQUIPMENT WITHIN THE ABSORPTION AREA AFTER PIPING HAS BEEN INSTALLED. THE WASTEWATER TREATMENT SYSTEM IS DESIGNED AND APPROVED BASED UPON THE INSTALLATION OF WATER CONSERVING FIXTURES AND A DESIGN FLOW OF 110 GPD PER BEDROOM. THE SYSTEM IS NOT DESIGNED TO ACCOMMODATE EXTREME WATER USE FIXTURES, SUCH AS JACUZZI-TYPE SPA TUBS OR WATER TREATMENT EQUIPMENT. THE INSTALLATION OF NON -CONSERVING WATER FIXTURES OR EXTREME WATER USE FIXTURES IS CONTRARY TO THE APPROVAL OF THIS WASTEWATER TREATMENT SYSTEM. ROOF, FOOTING, GARAGE, CELLAR AND SURFACE WATER DRAINAGE MUST BE EXCLUDED FROM THE WASTEWATER SYSTEM. CONSTRUCT DRAINAGE SCALE UPGRADE OF SYSTEM IN ORDER TO DIVERT SURFACE RUNOFF AROUND ABSORPTION FIELD. SEP77C TANK & ABSORPTION BED MUST BE INSPECTED BY LOCAL BUILDING DEPARTMENT AND DESIGN ENGINEER PRIOR TO BACKFILL AND FINAL GRADING. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO IDENTIFY THE NECESSARY PARTIES AND REQUEST INSPECTIONS. SYSTEM MATERIAL SPECIFICATIONS ABSORPTION FIELD AGGREGATE STONE IS TO BE 3/4" TO 1-1/2" WASHED CRUSHED STONE. EFFLUENT SEWER PIPE PIPING TO BE 4" SDR-35 OR SCHEDULE 40 PVC. INSTALL WITH 1/8" PER FOOT MINIMUM SLOPE. FILTER FABRIC FILTER FABRIC TO BE 4.8 OZ/SY NON -WOVEN SEPARATION FABRIC, TENCATE MIRAFI 140N OR EQUIVALENT. TOPSOIL PLACE 4" MINIMUM TOPSOIL OVER ENTIRE BACKFILL AREA. SEED, MULCH, AND ESTABLISH TURF. INSTALLATION DATE: 71512023 INSTALLED BY - NICK DAIGLE CONSTRUCTION RECORD DRAWING NOTE: A REPRESENTATIVE OF OUR OFFICE VISITED THE SITE DURING CONSTRUCTION AND IT IS MY OPINION THAT THE SYSTEM IS INSTALLED IN GENERAL CONFORMANCE WITH THE APPROVED PLAN AND THIS RECORD DRAWING. FINAL SURFACE FINISHING AND TURF ESTABLISHMENT 1S ONGOING. G. THOMAS HUTCHINS, P.E. 71612023 TAX MAP # 309.18-1-2 Dig Safely. New ® York ® Call Before You Dig 2 RECORD DRAWING 7/6/2023 Wait The Required Time Confirm Utility Response 1 REVISED PER TOWN COMMENT 6/19/2023 IM Respect The Marks EM Dig With Care 0 ISSUED FOR PERMIT 611612023 8 0 O— 9 6 2— 7 9 6 2 www.digsafelynewyork.com No. Revisions Date- 0 F WASTEWATER S Y,53TEM r"LA/V CX DETAILS y�® prepared for: Q7 David Cook CD acc 24 Island View Drive Town of Queensbury, County of Warren, State of New York 067pV79 4 Drawn: WGC Checked: GTH I Scale: NOTED Date: 611312023 SSI 169 Haviland Road ALTERATION OF THIS DOCUMENT EXCEPT BY Queensbury, NY 12804 292177-01 A LICENSED PROFESSIONAL ENGINEER IS A VIOLATION OF NYS EDUCATION LAW. (518) 745-0307 Phone Hutchins Engineering PLLC (518) 745-0308 Fax