97-492 •
CERTIFICATE OF OCCUPANCY •
TOWN OF QUEENSBURY
WARREN COUNTY, NEW YORK
January, 29 98
Date 19
i1� 1
97492
• This is to certify that work requested to be done as shown by Permit No.
has been. completed.
8 UNIT APARTMENT BUILDING
This structure may be occupied as a
LOT 12 HUNTER BROOK :LANE,
Location
Owner SCHERMERHORN, RICHARD JR.
TAX MAP. NO. 4 8. -3-3 4 . 10 By Order Town Board
TOWN OF QUEENSBURY
Director of Bldg. & Code Enforcement
BUILDING PERMIT
VALUE $ 300000T®WN OF QUEENSBURY No. 97492
TAX MAP NO. 48 . -3-34 . 10
WARREN COUNTY, NEW YORK
SCHERMERHORN, RICHARD JR.
PERMISSION is hereby granted to
LOT 12 HUNTER BROOK LANE
OWNER of property located at Street, Road or Ave.
8 UNIT APARTMENT
in the Town of Queensbury,To Construct or place a
at the above location in accordance to application together with plot plans and other information hereto filed and
approved and in compliance with the Town of Queensbury Building and Zoning Ordinance.
1. CIOPF1111$g4tsitOMMONS NORTH
QUEENSBURY, NY 12804
2. CONTRACTOR or BUILDERS Name
SCHERMERHORN, RICHARD, JR.
3. CONTRACTOR or BUILDERS Address
4. ARCHITECT'S Name
COMMONWEALTH
5. ARCHITECT'S Address
6. TYPE of Construction—(Please indicate by X)
( )Wood Frame ( ) Masonry ( )Steel ( )
7. PLANS and Specifications
8460 SO FT 8 UNIT APARTMENT AS PER PLOT PLAN SPECIFICATIONS
No.
8. Proposed Use
8 UNIT APARTMENT
1092 September 5 99
$ PERMIT FEE PAID -THIS PERMIT EXPIRES 19
(If a longer period is required an application for an extension must be made to the Building and Zoning inspector of the
town of Queensbury before the expiration date.)
5 September 97
Dated at the To ueensbury this Day of 19
1
SIGNED BY for the Town of Queensbury
B (ding a Zo .
.L. Building Permit Application
Own Of Queensbury - Dept. of Community Development, 742 Bay Road, Queensbury, IVY 12804 [761-8256J
ONrrOTIrrBUILDING & CODE. ENFORCEMENT
LjF Requirements prior to issuance - - -
A permit must be obtained before , of this permit: PERMIT FILE NO.97.-- ttqc: ,
beginning construction. No inspections PERMIT FEE PAID$ f � 0
0
1-1will be made until applicant has received . Zoning Board Action .
a VALID BUILDING PERMIT. All Area /Use RECREATION FEE PAID$
applicants' spaces on this application
MUST be completed and•the signature n Planning Board Action REVIEWED BY: Ids
of the applicant must appear on the
application form. 7t�x you SPR / Subdivision /Other Building Inspector
J Recreation Fee Payment
Applicant: Sr ANP.rvanec-)-No,rtiJCoAS$c ;,,NCoc'P• Owner: (,--r --
' 1 V _ C
Address: 79 YVlasA•ers C�o,Mr�o.v AL. Address:
•
Phone # ( .lg ) -l9 g - o Gig Phone # ( ) -
. Property Location: �0f ///. /e-c
/2 " r'oo k ZNo- 4
Tax Map Number 4�_f /3 `' lb
Subdivision Name: �N0VP_rlo od�C i��.rk
Section Block T.ot
NATURE OF PROPOSED WORK: ESTIMATED MARKET VALUE OF THE
)4 New Building: - CONSTRUCTION: $ ,30o�000
cresidenc'e / commercial
Addition to Building: --
residence / commercial OCCUPANCY INFORMATION:
Alteration to Building: Primary Building -
residence / commercial Single Family—Dwelling
Residence / Commercial Two Family cDwel7f15477- ,,;
no change to exterior size Family Dwell-1�-in ' ''T'
q IY ql ,,r 1
Office
Other Work (describe below) Mercantile AUG 26 1997
Manufacturing
X Other �' ,�
GROSS AREA OF PROPOSED STRUCTURE: `6 vn.. j`f, _ ,e_; _
If ADDITION, what will use
1st Floor Na30 sq. ft. of new addition be.? :
2nd .Floor 49.30 sq. ft.
Other Floors sq. ft•
(not unfinished cellar or basement) ACCESSORY BUILDINGS:
Detached Garage 1, 2 car
TOTAL FLOOR AREA: S1(0 O SQ. FT. Atta ed G age 1, 2 car
Privat torage Building
E
SIZE OF NEW STRUCTURE: 1092, Comme ci Storage Building
1 1S FEET X 33 FEET Ot r
Foundation Type: Gorcre--\-t? Will any second-hand or ungraded
' Number of Stories : a lumber be used? If so, for what?
(habitable space only) ,v v
Height (grade to ridge) : alto feet TYPE OF. HEATING SYSTEM:
Number of fireplaces and/or woodstove (circle all which •pl' es)
to be installed: O Electri_c_-/Q, �- // Wood
Forced Hot Air / - -saboard / Other
Person responsible for supervision of work as regards to building
codes is: Sc_tiec.,sne c)-o r,-1 C.ns-i-coo ;0N `C..nr p
Name Addresss Phone
Builder: S�L.ec'✓uerhorA) . • 778•-067 y
Plumber: Sltwe. Alley 7y7-5-45".3
mason: n aLe, k).,414v:r1 79 a- 13-7 I
Electrician: fv1 kp _ Co,,,i sky Hy- cfos
DECLARATION: Please sign below afteryou have carefully read the statement.
To the best of my knowledge the statements contained in this application, together with the plans
and specifications submitted, are a true and complete statement of all proposed work to be done on
the described premises and that all provisions of the Building Code, the Zoning Ordinance and all
other laws pertaining to the proposed work shall be complied with, whether specified or noted, and
that such work is authorized by the owner. Further, it is understood that Uwe shall submit prior to a .
Certificate of Occupancy•or Certificate of Compliance being issued, an AS BUILT PLOT PLAN by
a licensed surveyor; drawn to scale, showin ac location of project on premises.
Signature: t 1
'(owner, owner's agent, architect, contractor)
•
•
AUG 26 19.97
ENERGY CODE COMPLIANCE APPLICATION
SS TOWN OF QUEENSBURY, WARREN COUNTY•
9000 HEATING DEGREE DAYS •
Concliance Methods : PART 5 - Acceptable Practice Method -
1&2 Family Dwellings (only)
PART 6* - Thermal Rating - Component Trade Offs
1&2 Family Dwellings; Multi-Family
Dwellings (3 stories or less)
PART 4* - Design -by Component Performance -'
Commercial Buildings-Hi Rise Residential
*Requires submission of worksheets
APPLICANT' S NAME: PROPERTY LOCATION:
Sc�h e/•/14�/Ao/.t/ C�onS�/��7.0���/ 274 d co a/ ,2/(J
•
•
PART 5 METHOD OF COMPLIANCE BY ACCEPTABLE PRACTICE:
I . Gross Floor Area - 54/6 0 • scuare feet
2 . Type of Heat - Electric Oil Y Gas Other •
3 . Is building mechanically cooled? Yes s/ No
4 . Percentage of area of windows and doors V Over 17% Under 17%
5 . ?-VALUES FOR INSULATION GIVEN BELOW' MUST CORRESPOND TO R-VALUES AS
SHOWN ON PLANS SUBMITTED:
a . Roof • • R 30
b . Exterior walls R /9
c - Glazed areas R I'g
d_ Exterior doors • R •J5
e . Floors over unheated spaces - R /q
f . Edge of slab on grade (heated building) R //
g. Basement/cellar walls (above grade) R 1?
h. Basement/cellar walls (below grade) R /i
Heating/cooling-ducts-piping in unheated space R y-C,
6 . Service (domestic) hot *water heating device
Conforms to minimum efficiency per code • Yes. No
TEMPERATURE CONTROL MAXIMUM SETTING 1400 - WILL NOT BE EXCEEDED
Applica '_s S natu :// // Date Phone Number
•
INSPECTOR'S REMARKS:
•
•
•
•
a.,: :. :� 7is3'c- ti3w't '.eaF) "ffii fiY1'iPi.F4!Li s,..v�aui"ic"w'4:feeffal fa $``"+ `( ....:
?•�►Ap•plicat1ot for SEPTIC DZS1 AL HERMITS " •
• . . ' Town of Queensbury SC e:� ' ll)ta 7�
• r,�
beet. of Community Development '` t:
Permit No. .
Building Codes (ffice " .."J
742 Bay Road , -�—� Fee Paid $
Qiieensbury NY 12804
L'.... : • J
Location of property for installation: o 1 ,va}ec b r.�o k LA),,;: •
Property Owner's Name: e.r•1-.o t .0 ( riS�1'���.o CA.rp
Property Owner's Mailing Address: . s C cS Ct•-/V1 iv;is.A) �c'r 4 )-
Installer';! Name ..•:°Sc. � # 793-
�+%+-ti�.�.h��rv�:_ Cans+���'lo•N. .;:Phone =.0 ( 7 y .
Number of bedrooms (if residential)! . ._J(n Total daily flow' ,V Vo o
(residential compute @ 150 gal./bdrm.)
Tot ogr"apliy u flat, rolling; steep slope % of slope . '.
Sod Nature ;u,: acrid; loam; clay; other./depth'
Ground water'..at what depth? feet /,..Bedrock or Impervious Material: at what depth? — feet
••
• Percolation test not required; requt%d [ rate min perinch ] •
bomestic water.supply: municipal, well, other ..
if domestic water supply is a WELL; water supply from any septic absorption is feet..
PROPOSED SYS pEM_ • -
Septic taiilc �asd gallon (min mum size 1,000 cal) •
• 'file field _:;eacli trench feet% / Totalsysteni length feet
• Seepa a its ' number of ,. size each ft .b ft.
.
g p� O - Y •
Size of stone to be used: # / depth or thickness /, feet
j t
HOLDING TANK SYStEM:.:(if required)4•
• Nil nber of irks: ... Size of each: gallons
.
Alarm sy®tam and h ipaditect etectricat work bt+i be mapected by a'cerhfietl'agency
Foc'iyour#protection; please note that pursuant to Section 1 6-29 of the Code of the Ton of Queeaabury, any permit or
upon
or is granteii m retiancco i>pim any Material mw
ierepreeetitation or failure to make a
material'fact or ci aumstance known by or on behalf of nit applicant,;Atilt be void:
I h ve^earl the tegiilahong with respect to this application ' agree ti► b' 'e and all iecidiremente of the Town of
Queenebury Sanitary Sewage Disposal Onhnano
Signature of responsible person: Date: 6.-97
., TOWN OF QUEENSBURY
/"l�al_ BUILDING & CODE ENFORCEMENT
`i 742 BAY ROAD
� � QUEENSBURY NY 12804
(518) 761-8256
ARRIVE: DEPART: INSP:
FINAI. INSPECTION REPORT - 'RESIDENTIAL
DATE INSp-EC ��EQUG���ChEIVED:
NAME `,3 rnlfn ?�r{�
LOCATION W I I kL � ° qJ°� ( �_
G DATE PERMIT 1 T7 j 1
TYPE OF STRUCTURE f
FOOTINGS FOUNDATION BACKFILL FRAMING
ROUGH PLUMBING _ SEPTIC _ INSULATION _
FINAL ELECTRICAL WOODSTOVE OR FIREPLACE
N/A YES NO
CHIMNEY HEIGHT/B VENT/HEIGHT
PLUMBING VENT
ROOFING
EXTERIOR FINIS
DECK/PORCH/STEPS/ ILINGS
RELIEF VALVES
FURNACE/HOT WAT OPERATING
INTERIOR TRIM/PRIVACY DOORS
FINISH FLOORS:
BATH/KITCHEN WATERTIGHT
OTHER FLOORS •SWEEPABLE
OTHER FLOORS CARPETED
STAIR CLEARANCE/RAILINGS
SMOKE DETECTORS
BATHROOM FANS
PLUMBING FIXTURES
FOUNDATION INSULATION
GARAGE FIRE PROOFING
DOOR CLOSERS
FINAL ELECTRICAL
SITE PLAN/VARIANCE REQ.
FINAL SURVEY PLOT PLAN
OK TO ISSUE C/O OR C/C
1-71:1A.A gh(LiC\ (L. R 6 fi-L_
ipa----
,
MULTIPLE DWELLING,HOTEL, MOTEL, APART 141(--- ------D‘
FINAL INSPECTION REPORT
Office No. (518)761-8256
Building& Code Enforcement Date inspection request received: 1 -D e/
Dept. of Community Development
Town off Queensbury Arrive I2 tam part
742 Bay Road Inspector's Initial —
Queensbury,NY 12804
NAME 0111Pc-1-- SGthiss____ a 1.� z�-s'- PERMIT# 2--
LOCATION ,{—o T" / � `1f—e—N c'-3 -- DATE I -- )-9-e V
TYPE OF STRUCTURE , °- 6
N/A YES NO COMMENTS
Chimney Height/'B"Vent/Direct Vast Location g . .
,
Fresh Air Intake
Plumb Vent through roof Roof completeExterior finish completeInterior/exterior railings 34 in.to 38 in.
Exterior handrails,balconies,landing 18 in.or more
Interior handrails stairs both sides 3 or more risers
Guardrails 42 in. f i�
Ballisters 4 in.spacing I
Doors 36 in.
Headroom 71 on stairs Y .
Handrail exterior stairs both sides more than 3 risers
Floor finish
Bathroom/kitchen watertight
Interior handrails balconies/landing 18 in.or more
Railing across window in stairwells i
V
Smoke detectors: ✓/
every level t//
every bedroom 1/
outside every bedroom
inter connected
Bathroom fans
Plumbing fixtures V
Foundation insulation
Fire separation 3, 1,2 hour • !
Fire walls 1,2,3,hour J
3/4,Fire doors , 1 'V2,2 hour
Handicapped Accessibility
Handicapped parking ti//
Handicapped signage V r
Finish grade V/
Gas valve shut-off exposed/regulator 18 in.above grade ✓✓✓/
Gas furnace shut-off within 30 ft.or within line of site V Oil furnace shut-off at entrance to furnace area
Fumace/hot water heater operating
Relief valve(s)installed 1
Garage fireproofing
✓
Garage penetrations sealed /
Furnace in separate room protected(in garage) V J
Light ventilation per room
Safety glazing 18 in.or less from floor j /
Final Electrical ' /• V
Site Plan/Variance required ,/ i
Final Survey Plot Plan
As-built septic system layout required
Okay to issue temp C/O
Okay to issue permanent C/O(Certif.of Occupancy)
Okay to issue C/C(Certif.of Compliance)
l�
• f
MULTIPLE DWELLING, HOTEL, MOTEL,APARTME 1 1
FINAL INSPECTION REPORT
Office No. (518)761-8256
Building& Code Enforcement Date inspection request received: I^' '‘:)l
Dept. of Community Development
Town off Queensbury Arrive n i Depart 1 jik. pm
742 :.ay Road Inspector's Initials G'
Queensbury,NY 12804
NAME ( C.1 PERMIT# 9 - S Z-
LOCATTON J—e) L a•- 1-v-> -- DATE 1 —- g/ —clTYPE OF STRUCTURE �ti-e-,
N/A YES NO COMMENTS
Chimney Height/"B"Vent/Direct Vent Location
Fresh Air Intake
Plumb Vent through roof V./
Roof complete , / •
Exterior finish complete V/
Interior/exterior railings 34 in.to 38 in. V
Exterior handrails,balconies,landing 18 in.or more
Interior handrails stairs both sides 3 or more risers
Guardrails 42 in. �//
Banisters 4 in.spacing �//
Doors 36 in. �✓
Headroom 71 on stairs .
Handrail exterior Stairs both sides more than 3 risers
Floor finish I
Bathroom/kit.dien watertight
Interior handrails balconies/landing 18 in.or more
Railing across window in stairwells
Smoke detectors: I
every level every bedroomoutside every bedroom
inter cormeied
Bathroom fans
Plumbing fixturesFoundation insulationFire separation 3/4, 1,2 hourFire walls 1,2,3,hour
Fire doors 3/4,1 1/2,2 hour V
Handicapped Accessibility .,�j
Handicapped parking • //
Handicapped signage f
Finish grade V
Gas valve shut-off exposed/regulator 18 in.above grade
Gas furnace shut-off within 30 ft.or within line of site
Oil furnace shut-off at entrance to furnace area
Fumace'hot water heater.operating 'N./j
Relief valve(s)installed
Garage fireproofing J/
Garage penetrations sealed IFurnace in separate room protected(in garage) /
Light ventilation per room V
Safety glazing 18 in.or less from floor
Final Electrical
/V I
/
Site Planariance required J •
Final Survey Plot Plan
As-built septic system layout required
Okay to issue temp C/O
Okay to issue permanent C/O(Certif.of Occupancy)
Okay to issue C/C(Certif.of Compliance)
MULTIPLE DWELLING,HOTEL, MOTEL,APARTMENT
FINAL INSPECTION REPORT
Office No. (518)761-8256
Building& Code Enforcement Date inspection request received:
Dept. of Community Development
Town of Queensbury Arrive4icantpart
742 Bay Road Inspector's Initi:>> lak7
Queensbury,NY 12804 .
NAME Sit C1-1 im.1kEst t E.F,-Va PERMIT# i —
LOCATION 1_4p7 1 Z Irk013Thil, V-Ra--)V-. DATE t —2—c1-9?
TYPE OF STRUCTURE C- •
N/A YES NO COMMENTS
Chimney Height/"B"Vent/Dired Vent LocationI
Fresh Air Intake Plumb Vent through roofRoof complee •
Exterior finish complete
Interior/exterior railings 34 in.to 38 in.
Exterior handrails,balconies,landing 18 in.or more
Interior handrails stairs both sides 3 or more risers V
Guardrails 42 in. /,
Banisters 4 in.spacing j//
Doors 36 in. • Y
Headroom 7 ft-on stairs
Handrail exterior stairs both sides more than 3 risers N
Floor finish
Bathroom/kitchen watertight
Interior handrails balconies/landing 18 in.or more
Railing across window in stairwells
Smoke detectors:
every level
every bedroom
outside every bedroom
inter connected Y
Bathroom fans
Plumbing fixtures
4/4 •
Foundation insulation
Fire separation 3/4, 1,2 hour
Fire walls 1,2,3,hour
Fire doors 3/4, 1 '/2,2 hour /
Handicapped Accessibility
Handicapped parking V
Handicapped signage
Finish grade
Gas valve shut-off exposed/regulator 18 in.above grade
Gas furnace shut-off within 30 ft.or within line of site
Oil furnace shut-off at entrance to furnace area
Fumac e'hot water heater operating
Relief valve(s)installed
Garage fireproofing
Garage penetrations sealed
Furnace in separate room protected(in garage)
Light ventilation per room / J
Safety glazing 18 in.or less from floor
Final Electrical
Site PlanNariance required
Final Survey Plot Plan QCa(=\IFDif
/
As-built septic system layout required V
Okay to issue temp C/O
Okay to issue permanent C/O(Certif.of Occupancy)
Okay to issue C/C(Certif.of Compliance)
_
i
MULTIPLE DWELLING,HOTEL,MOTEL,APAR y NT
FINAL INSPECTION REPORT7/37-1-\
Office No. (518)761-8256 11=��,�?
Building& Code Enforcement Date inspection request received: j
Dept. of Community Development
Town of Queensbury Arrive `� S-u��epart ' , I
742 Bay Road Inspector's Initials G
Queensbury,NY 1
,eir ,i
NAME PERMIT# _ ` c
LOCATION DATE '
TYPE OF STR CTURE / f�
tN//A YES NO COMMENTS
Chimney Heightf'B"Vent/Direct Vent Location 1//
Fresh Air Intake i
�
Plumb Vent through roof v
Roof complete V/ •
Exterior finish complete V
Interior/exterior railings 34 in.to 38 in. O
Exterior handrails,balconies,landing 18 in.or more
Interior handrails stairs both sides 3 or more risers
Guardrails 42 in.
Balusters 4 in.spacing
Doors 36 in. Vii
Headroom 7 ft.on stairs / .
Handrail exterior stairs both sides more than 3 risers ✓ •-
—
Floor finish - - -- —
Bathroom/kiichen watertight
Interior handrails balconies/landing 18 in.or more
Railing across window in stairwells
Smoke detectors: J/
every level Vi
every bedroom Vj
outside every bedroom t
inter connected V/
Bathroom fans
Plumbing fixtures ✓V/
Foundation insulation Y
Fire separation 3/a, 1,2 hour
Fire walls 1,2,3,hourVi
Fire doors'/, 1 '/2,2 hour ✓
Handicapped Accessibility .✓
Handicapped parking
Handicapped signage ✓ /
Finish grade ✓
Gas valve shut-off exposed/regulator 18 in.above grade
Gas furnace shut-off within 30 ft.or within line of site
Oil furnace shut-off at entrance to furnace area .
Furnace/hot water heater operating / _
Relief valve(s)installed Y
Garage fireproofing VVij
Garage penetrations sealed
Furnace in separate room protected(in garage)
Light ventilation per room
Safety glazing 18 in.or less from floor i
I
Final Electrical
Site Plan/Variance required
Final Survey Plot Planii '
As-built septic system layout required
Okay to issue temp C/O
Okay to issue permanent C/O(Certif.of Occupancy)
Okay to issue C/C(Certif.of Compliance)
—'J MULTIPLE DWELLING,HOTEL, MOTEL,APAR b 4/507)-
FINAL INSPECTION REPORT
Office No. (518)761-8256
Building& Code Enforcement Date inspection request received:/-- J"
Dept. of Community Development
Town off Queensbury Arrive atitpart` :AO i ri
742 Bay Road Inspector's Initials INc
Queensbury, 12804
7
ma
NAME --- PERMIT# -7l �
LOCATION4 / f30 DATE /-- d
TYPE OF STRUCTURE 1
N/A YES NO COMMENTS
Chimney HeightP'B"Vent/Direct Vent Location •✓
Fresh Air Intake , /
Plumb Vent through roof V/
Roof complete V/ •
Exterior fmish complete ✓
Interior/exterior railings 34 in.to 38 in. 4 Exterior handrails,balconies,landing 18 in.or more
Interior handrails stairs bash sides 3 or more risers /'
Guardrails 42 in. V/
Ballisters 4 in.spacing /l
Doors 36 in.
Headroom 7$_on stairs /
Handrail exterior stairs both sides more than 3 rises ✓ — —�—-- - _ --- — -- -
Floor finish —
Bathroom/kitchen watertight
Interior handrails balconies/landing 18 in.or more / ,f
Railing across window in stairwells f /
Smoke d�e�ors: ij
every level �,//
every bedroom j
outside every bedroom `,///
inter connected
Bathroom fans
Plumbing fixtures
Foundation insulation ,�
Fire separation 3/<, 1,2 hour . J/ , --fkm fv a � lA
Fire walls 1,2,3,hour �i �� V-1-
Fire doors 3/4, 1 1/2,2 hour C-ELL �c 2— 5 F-`-
Handicapped Accessibility
Handicapped parking
Handicapped signage
Finish grade
Gas valve shut-off exposed/regulator 18 in.above grade
Gas furnace shut-off within 30 ft_or within line of site
Oil furnace shut-off at entrance to furnace area J
Furnace/hot water heater operating t
Relief valve(s)installed
Garage fireproofing
Garage penetrations sealed
Furnace in separate room protected(in garage) Viii
i
Light ventilation per room
Safety glazing 18 in.or less from floor Vil
Y
Final Electrical
Site Plan/Variance required l
Final Survey Plot Plan
As-built septic system layout required
Okay to issue temp C/O
Okay to issue permanent C/O(Certif.of Occupancy)
Okay to issue C/C(Certif.of Compliance)
aee/
MULTIPLE DWELLING,HOTEL,MOTEL,APARTME 8
FINAL INSPECTION REPORT //el."
Office No. (518)761-8256 Building& Code Enforcement Date inspection request received: l" '`'.9'
Dept. of Community Development j /� �
Town of Queensbury Arri `6 am/pm Depart '� m/pm
742 Bay Road Inspector's Initials
Queensbury,NY 2804
' �1/7-- �-
NAME �� LG-�� PERMIT#
LOCATION 7- / L , .,mJ� q-G� DATE
TYPE OF STR CTURE / �• 6
N/A YES NO COMMENTS
Chimney HeightP'B"Vent/Direct Vent Location ✓�
Fresh Air Intake
Plumb Vent through roof �{'
Roof complete •
Exterior finish complete �/
Interior/exterior railings 34 in.to 38 in. .
Exterior handrails,balconies,landing 18 in.or more 1 v/
Interior handrails stairs both sides 3 or more risers
Guardrails 42 in. I Ballisters 4 in.spacing
Doors 36 in. ,/
Headroom 7 ft.on stairs �/
Handrail exterior stairs both sides more than 3 risers Vv./ '
Floor finish
Bathroom/kitchen watertight
Interior handrails balconies/landing 18 in.or more %/i
Railing across window in stairwells
Smoke detectors:
every level v
every bedroom
outside every bedroom Viinter connected
Bathroom fans
Plumbing fixtures
Foundation insulation ✓
Fire separation 3 , 1,2 hour
Fire walls 1,2,3,hour IQ
Fire doors 3/4, 1 'V2,2 hour /
Handicapped Accessibility y// AP� 4
Handicapped parking f /� P2t 0 4 Jd
Handicapped signage �// ®(0)I- 1 G 0
Finish grade 'fit�A-� (A)4;Pee/ /b) .2Gas valve shut-off exposed/regulator 18 in.above grade
Gas furnace shut-off within 30 ft.or within line of site /V ,
Oil furnace shut-offal entrance to furnace area
Furnace/hot water heater operating
Relief valve(s) Y installed U
Garage fireproofing
Garage penetrations sealed J
Furnace in separate room protected(in garage) tf
Light ventilation per room
Safety glazing 18 r 1 8
/V 1, 7 m fl
wr_______ i
Final Electrical
Site Plan/Variance r uir i Final Survey Plot Plan U' iiVIT 5V 206"Y r2 Prat.►/+-t— �6,90g�x14
As-built septic system layout required j
Okay to issue temp C/O
Okay to issue permanent C/O(Certif.of Occupancy)
Okay to issue C/C(Certif.of Compliance)
I
.
• MULTIPLE DWELLING, HOTEL, MOTEL,APARTME r
FINAL INSPECTION REPORT �i
Office No. (518)761-8256 , /elh
Building& Code Enforcement Date inspection r uest received: ??7,j/1
Dept. of Community Development i zi
Town of Queensbury Arrive I pm Depart/-(5 am/pm
742 Bay Road Inspector's Initials 0 g
Queensbu 4 12804
NAME v, -- —J )--)'-----.. PERMIT#
'9'7,z.2.-- 1/5;".
LOCATION " /A V/ 0. DATE I yv--
io
TYPE OF STRUC
c�
N/A YES NO __ COMMENTS
Chimney Heightf'B"Vent/Direct Vent Location ' 1/4Fresh Air Intake
Plumb Vent through roof yei
Roof complete •
Exterior finish complete
Interior/exterior railings 34 in.to 38 in. it i
Exterior handrails,balconies,landing 18 in.or more
Interior handrails stairs both sides 3 or more risers
Guardrails 42 in.
Ballisters 4 in.spacing \b/://
Doors 36 in.
Headroom 7 ft.on stairs
Handrail exterior stairs both sides more than 3 risers - .I
Floor finish
‘11/ '
Bathroom/kitchei watertight
Interior handrails balconies/landing 18 in.or more i ,
Railing across window in stairwells
Smoke detectors: V:(//
every level
every bedroom
outside every bedroom
inter connected
Bathroom fans
Plumbing fixtures
/ iy
Foundation insulation
Fire separation 3/4, 1,2 hour
Fire walls 1,2,3,hourVA _
Fire doors 3/4, 1 '/2,2 hour
Handicapped Accessibility l/Handicapped parking _ /
Handicapped signage V /
Finish grade
Gas valve shut-off exposed/regulator 18 in.above grade
Gas furnace shut-off within 30 ft.or within line of site V
Oil furnace shut-off at entrance to furnace area
Fumace/hot water heater operating V
Relief valve(s)installed /
Garage fireproofing /�
Garage penetrations sealed 9
Furnace in separate room protected(in garage) /
Light ventilation per room �/
Safety glazing 18 in or ss,rom floor. y{�
Final Electrical t C.l.'7 / °{ram �]ip��
Site lPlan/Variance Survey
in/
ed _ tS M i i ,�v2 J6-U Q- E—).4.14-L /Y /
Final Survey Plot Plan yiJ
As-built septic system layout required /
Okay to issue temp C/O J/
Okay to issue permanent C/O(Certif.of Occupancy)
Okay to issue C/C(Certif.of Compliance)
,RESIDENTIAL FINAL INSPECTION REPORT
Office No. (518) 761-8256
Building &Code Enforement .7 V" Arrive'-VD Ins i� :.
Dept. of Community Development c
Town of Queensbury Date Inspection Request R;% eived.
742 Bay Road
Queensbury, NY 12804 %' c 2-
NAME ‘402p,t6LP/yog.,4) PERMIT NO. 77 /
LOCATION .ky ►'/24Pi L' ti/W<_ cgk'K - DATE Vz 3(96
TYPE OF STRUCTURE 4-Pr /ior/S—
!- • •u..unkit _-
Chimney g Hei ht/"B" Vent/Direct Vent Location t/
Fresh Air Intake MIMI
Plumb Vent Through Roof �—
Roof Complete Willil_—
Exterior Finish Complete
Interior/Exterior Railings 30" to 36" M' s
Exterior Handrails, Balconies, Landing 18 in. or more M �=
Interior Handrails Stairs Both Sides 3 or More Risers ��'-
Grade 2% Away From Foundation IIM' INIffir
8" Clearance To Sill Plate
Gas Valve Shut-Off Exposed/Regulator 18" Above Grade MEI
Gas Furnace Shut-Off within 30 Feet or within Line of Site A�
Oil Furnace Shut-Off at Entrance to Furnace Area
Furnace/Hot Water Heater Operating MINI
Relief Valve(s) lnstalled Mill — _ — — —
Headroom 6 ft. 6 in. On Stairs
Basement Stairs 6 ft. 4 in. INOM
Handrail Exterior Stairs Both Sides More Than 3 Risers MEI
Interior Privacy/Trim/Doors/Main Entrance 36"
Floor Finish AIM
Bathroom/Kitchen Watertight
Interior Handrails Balconies/Landing 18 in. or more ' /
t WAIN
Across Window in Stairwells WM.
4 Smoke Detectors:
every level MANI
every bedroomeryMal
outside every bedroom
inter connected
Bathroom Fans MN!
Plumbing Fixtures �„_
Foundation Insulation
1A/4 Hour Fire Door/Door Closer MIMI
Garage Fireproofing IMINFAIIII
vdaraga Penetrations Sealed % C:(.L '�a
Furnace In Separate Room Protected (In Garage) ffillEil
Mira_
Light Ventilation Per Room• �—
Safety Glazing 18" or Less From Floor
Final Electrical M-
Site Plan/Variance Required MINIM
ainal Survey Plot Plan iffil.11011
As Built Septic.System Layout Req. EIIIIIIINII
Okay to Issue Temp C/O 1111111111111.
Okay to Issue Permanent C/O
A(A) , PO-
7,3e . Cd=`
,)
RESIDENTIAL FINAL INSPECTION REPORT
Office No. (518) 761-8256 / �/�
Building &Code Enforement Arrive: /O!A— Insp:
C-0-----
Dept. of Community Development
Town of Queensbury Date Inspection Request Received:
742 Bay Road
Queensbury, NY 12804 lt?--
NAME ‘ Gkcl=t-t.ogv+) PERMIT NO. 7 ( I
LOCATION La r 0 (7✓,#'i 6. getir 6?-K- DATE i/A-3//r6
TYPE OF STRUCTURE ,4 : r ou-e--
Chimney Height/"B" Vent/Direct Vent Location 4/
Fresh Air Intake WM_
Plumb Vent Through Roof M
EI _AI
Roof Complete
ININI
Exterior Finish Complete ■r/!_
Interior/Exterior Railings 30" to 36" ��=—
Exterior Handrails, Balconies, Landing 18 in. or more i
Interior Handrails Stairs Both Sides 3 or More Risers MO' t
Grade 2% AwayFrom Foundation I
8" Clearance To Sill Plate WA 1111111111111111 '
Gas Valve Shut-Off Exposed/Regulator 18" Above Grade I;=-11111111= /
Gas Furnace Shut-Off within 30 Feet or within Line of Site
Oil Furnace Shut-Off at Entrance to Furnace Area AIM
Furnace/Hot Water Heater Operating =I=
Relief Valve(s) Installed Y
Headroom 6 ft. 6 in. On Stairs 111101—
Basement Stairs 6 ft. 4 in. MI_
Handrail Exterior Stairs Both Sides More Than 3 Risers
Interior Privacy/Trim/Doors/Main Entrance 36" IRE
Floor Finish WA=
Bathroom/Kitchen Watertight • M_
Interior Handrails Balconies/Landing 18 in. or more \' A
IM
Railing Across Window in Stairwells k' MEW `
Smoke Detectors: 5' ` &..L U, w _
every level IN
every bedroom IVA
outside every bedroom 1121
inter connected =
Bathroom Fans -��
Plumbing Fixtures
Foundation Insulation ouvra—.
3/4 Hour Fire Door/Door Closer nrilE 'sQJU'e P-'W I 11"n.) C-
Garage Fireproofing MIMI=
Garage Penetrations Sealed=
Furnace In Separate Room Protected (In Garage)
Light Ventilation Per Room• -A`•—
Safety Glazing 18" or ' .s• F m Floor NITEA
Final Electrical 1, , /ti _6-(5 ii__, •
Site Plan/Variance R-.uired all==-
Final Survey Plot Plan
As Built Septic System Layout Req. =_-
Okay to Issue Temp C/O
Okay to Issue Permanent C/O A.aAW O 3 --
Okay to Issue C/C
COMMONWEALTH ELECTRICAL INSPECTION SERVICE,INC.
Main Office 357 Elwyn Terrace — Manheim;PA 17545 q 7.-c/-q ',
MUNICIPAL CERTIFICATE - ELECTRICAL APPROVAL
Panel Board No. Cert. 5 2 5 4 1 Cut-in Card No.
Owner Sa 1-1-E/2414 Giz. /e,#i e.jiuv%`
Occupant A /��` /�
LocationL-0 ( I� /em� u1 MX .6.72 tf 4 02
Installation Consisting of,/56 Via. it p'3O r Rer- '? 3 z Z-( • es
&-me-- ,, L s •T"L'5 8 Rfr-A., e5 9, Rye—R 9f .�/ld.4f
Y . ....... -kI:fr; S
Installed By '/ - e2/t1V Lic.#
The conditions following governed the issuance of this certificate,and any certificate previously
issued is cancelled:—
This certificate only covers the electrical equipment and installation conditions as of date. Upon
the introduction of additional equipment or alterations, applications •l] be promptly made for
inspection.
Inspectors of this Company shall have the privilege of mak' g ins ect' ns at any time, and if its
rules are violated,late the Company shall have the right to revo t' t, ert' ica e.
Date./ Q '9 (1 INSPECTOR
ember N_F_P_A__I.A.E_I_
. ,
TOWN OF QUEENSBURY
BUILDING & CODE ENFORCEMENT
531 Bay Road
Queensbury NY 12804
518-745-4447
SEPTIC DISPOSAL SYSTEM INSPECTION
• /
Name \ /
L-71
Location 944,1-4,
Date / 1133/t1 Permit #
SOIL TYPE: Sand-Loam-Clay-
Results of Percolation Test-
(if applicable) Rate-Minu e/Inch
TYPE OF SYSTEM:
ABSORPTION FIELD: Tota Length
Length of each trench
Depth of trenches
Size of stone
SEEPAGE PITS: Nump7;-
Size - ft. ft.
Stone size
PIPING: Size Type
Bldg. to Tank
Tank to Dist. Box
Dist. Box to Field/Pit
Openings Sealed? Yes No Partial.
LOCATION/SEPARATIONS:
Foundation to Tank feet
Foundation to Absorption feet
Separation of Pits feet
Conforms as per Plot Plan Yes No
LOCATION OF SYSTEM ON PROPERTY:
(circle one)
Front - Rear .- Left Side - Right Side
Middle Front - Middle Rear
COMMENTS:
AP-tr,
(7
•
or,m
SYSTEM USE APPROVED: YES' _0,)
Arrived: 02,6-6
Departed:
Oh'
Building Inspector
Pa)/\ q-P.akoj
TOWN OF QUEENSBURY
BUILDING & CODE ENFORCEMENT
742 . Bay Road
Queensbury NY 12804
(518) 761-8256
SEPTIC DISPOSAL SYSTEM INSPECTION
Name Q PN\g'1� T�
Location , � / r ) L, 1(00(
Date 2q7peit #q"1-LIci
SOIL TYPE: and LO-Clay-
Results of Percolation Test-
(if applicable) Rate-Minute/Inch
TYPE OF SYSTEM:
ABSORPTION FIELD: Total L ,: 9 th c O ' ecr4
Length of each trench AllEak
Depth of trenches BONI
Size of stone: — AE!i'
SEEPAGE PITS: mber
Size - ft. .g1/,1ft.
Stone size Alf v
PIPING: Size Type
Bldg. to Tank
Tank to Dist. Box 4" ski
Dist. Box to Field/P
Openings Sealed? es No Partial
LOCATION/SEPARATION . /0
Foundation to Tank feet
Foundation to Absorption ? feet
Separation of Pits y feet
Conforms as per Plot Plan a No
LOCATION OF SYSTEM ON PROPERTY.
(circle or
Front - ,yart Left Side - Right Side
Middle Front - Middle Rear
COMMENTS:
/ Az_ `•et
f
SYSTEM USE APPROVED: 40 NO
Arrived: Jt3cs
Departed: f
r-P
Building Inspector
\ Ql,C DR
TOWN OF QUEEN RC J T •
r,`�'z� `"'• BUILDING & CODE ENFORCEMENT
•I 742 BAY ROAD
QUEENSBURY NY 12804
�� ` (518) 761-8256
ARRIVE: y'JU DEPART: 34aV 5NSP: k �.
FINAL INSPECTION REPORT/
COMMERCIAL MULTIPLFLDWELLINO
(hotel, motel, pt complex
DATE INSPECT ON REQUEST RE EIVED:
NAME S
LOCATION
DATE1\ 13"9.-7 PERMIT # Cn� 1,
• TYPE OF STRUCTURE
FOOTINGS BACKFILL FRAMING PLUMBING_
INSULATION
N/A YES NO
CHIMNEY/"B" VENT/HEI HT
PLUMBING VENT/FIXTURES
ROOFING
EXTERIOR FINISH
HEATING/HOT WATER
RELIEF VALVES
FLOORS •
FOUNDATION INSULATION
INTERIOR STAIRS/RAILINGS
STOCKROOM ENCLOSURE
Ii =IRE/DEMISE WALLS PENETRATION
FIRE DAMPERS
CEILING FIRE STOPPING
FIRE DOORS/CLOSERS °C<
EXIT DOOR HARDWARE
EXIT STAIRS/RAILS
PLATFORM/ELEVATOR •
HANDICAPPED ACCESS
HANDICAPPED BATHS
HANDICAPPED PARKING
FINAL ELECTRICAL
SITE PLAN/VARIANCE REQ.
FINAL SURVEY PLOT PLAN, IF REQ
OK TO ISSQ C/O OR C/C
I) 0LJ( O 0 (518) 761-8256
TOWN OF QUEENSBURY ,
BUILDING & CODE ENFORCEMENT
742 BAY RD., QUEENSBURY NY 12804 1t: " .
_ /
INSPECTOR'S REPORT: ARk2_16bDEPAR'���i
/ ��� 7REQUEST FOR, INSPECTION RECEIVED: / /� �'
NAMEa �, Sl'�YL\S�('Ld
LOCATION ) 1 a Wlf� fV� MO
DATE -D`'ci 1 n/,P,ERRMIT A q - �9 �j
TYPE OF STRUCTURE: Aye i
RECHECK V, PROVED
\ • N/ YES NO
FOOTINGS/PIERS
MONOLITHIC POUR FORM
REINFORCEMENT IN PLA\E /
THE CONTRACTOR IS RESPONSIBLE FOR
PROVIDING PROTE TION ROM FREEZING
FOR 48 HOURS FOLLOWING THE PLACE- /
MENT OF THE CONCRETE. \ /
MATERIALS FOR THIS PURPOSE ON SITEf_
FOUNDATION/WALLPOUR • /
1
REINFORCEMENT IN PLACE
FOUNDATION/DAMPPROOFING /
_
BACKFILL APPROVAL `C �
' , r.
PLUMBING VENT/VENTS IN PLACE}
I.
ROUGH PLUMBING i VI-) _
PLUMBING UNDER SLAB %9
FRAMING: a .4
JACK STUDS/HEADERS I r
BRACING/BRIDGING I ‘
JOIST HANGERS I 1
JACK POSTS MAIN BEAM I
AIR INFILTRATION BARRIER
H ATING ROUGH-IN ! \
i -
INSULATION `/t
1
FOUNDATION WALLS INTERIOR R- _
FOUNDATION WALLS EXTERIOR R-
, _ _FLOORS 1-1--_ -- � R_ _-
WALLS t7 8 , ),v) F 1 R- Y
�
CEILING L( I R-,
IL
DUCT WORK OR PIPING IN �I
UNHEATED SPACES R- - ,
•
•
t •
(518) 761-8256
/VOLD
TOWN OF QUEENSBURY
BUILDING & CODE ENFORCEMENT
742 BAY RD., QUEENSBURY NY 12804
INSPECTOR'S REPORT: ARRVIaa DEPART '� `\
ro
REQUEST R I PECTION RECEIVED: vi _, 1
NAME c r
LOCATION ,1,1Ki -)f ;
DATE 0 -3 PERMIT 0 � 1-LGR
TYPE OF STRUCTURE:
RECHECK APPROVED
N/A YES NO
FOOTINGS/PIERS
MONOLITHIC POUR FORM
REINFORCEMENT IN PLACE
THE CONTRACTOR IS RESPNSIBLE FOR
PROVIDING PROTE TION 'ROM FREEZING
FOR 48 HOURS FOLLOWI a THE PLACE-
MENT OF THE CONCRETE. _
MATERIALS FOR THIS PURPOSE ON SITE
FOUNDATION/WALLPOUR
REINFORCEMENT IN PLACE
FOUNDATION/DAMPPROOFING
BACKFILL APPROVAL
PL)MBING VENT/VENTS IN PLACE ,
' OUGH PLUMBING
PLUMBING UNDER SLAB
F ING: _ .. /
JACK STUDS
/HEADERS . •`6J
BRACING/BRIDGING 'r 0+„
JOIST HANGERSIJMILi►7,;.•4i9J • PA.
JACK POSTS/MAIN BEAM 3
AIR INFILTRATION BARRIER
HEATING ROUGH-IN
INSULATION:
FOUNDATION WALLS INTERIOR R-
FOUNDATION WALLS EXTERIOR R- _
FLOORS R-
WALLS R-
CEILING R-
DUCT WORK OR PIPING IN
UNHEATED SPACES R-
* rezm
T‘6�is1:>k &_-_AL PE3oE oa.
v tr.
J o` -TV_O5 C
of 1f g-V\cik\L_ t)1 TZ0',5 off® r
g"\Y)t-A (518) 761-8256
TOWN OF QUEENSBURY
BUILDING & CODE ENFORCEMENT R # '
742 BAY RD., QUEENSBURY NY 12804
R `
INSPECTOR'S REPORT: AR t)DEPA( INTS -�
REQUEST FOR I PECTION� RECE VED: / �ipv
NAME SC f V 1IVn.ii'n/v
LOCATION I i/-I n y b]ra{5
/DATE 0- (� 7 �PERRMIT A 9- /
TYPE OF STRUCTURE: / , j2 -
RECHECK 11�� APPROVED
N/A YES NO
FOOTINGS/PIERS
MONOLITHIC POUR FORM i
REINFORCEMENT IN MACE _
THE CONTRACT4 8 RESPONSIBLE FOR
PROVIDING PROTE TION FROM FREEZING
FOR 48 HOURS FOLLOWING THE PLACE-
MENT OF THE CONCRETE.
MATERIALS FOR THIS PURPOSE ON SITE
FOUNDATION/WALLPOUR
REINFORCEMENT IN PLACE
FOUNDATION/DAMPPROOFING
BACKFILL APPROVAL
PLUMBING VENT/VENTS IN PLACE
ROUGH PLUMBING
PLUMBING UNDER SLAB
FRAMING:
JACK STUDS/HEADERS
BRACING/BRIDGING
JOIST HANGERS
POSTS MAIN BEAM
R INFILTRATION BARRIER
HEATING ROUGH-IN
INSULATION•
FOUNDATION WALLS INTERIOR R-
FOUNDATION WALLS EXTERIOR R-
FLOORS R-
WALLS R-
CEILING R-
DUCT WORK OR PIPING IN
UNHEATED SPACES R-
TOWN OF QUEENSBURY
BUILDING & CODE ENFORCEMENT
742 Bay Road
Queensbury NY 12804
(518) 761-8256
SEPTIC DISPOSAL SYSTEM INSPECTION
Name 4A0(41e1106‘)
Location _ ' ( I<V..'
Date 2.3 Permit # i7 7—412--
SOIL TYPE: Sand Loam-Clay-
Results of Percol . ion est- .
(if applicable) '-a = 'inute/Inch
TYPE OF S -
ABSORPTION FIE 1 : Total Length
Length of each trench
Depth of trenc es
Size of stone
SEEPAGE PITS: umber-
Size - ft. x ft.
Stone size
PIPING: Size Type
Bldg. to Tank i "
Tank to Dist. Box
Dist. Box to Field/P.
Openings Sealed? Ye 1. No Partial
LOCATION/SEPARATION .
Foundation to Tank /$—feet
Foundation to Absorption feet
Separation of Pits . _ feet
Conforms as per Plot Plan No
LOCATION OF SYSTEM ON PROPER
(circle on-
Front - • i''-Left Side Right Side
Middle Front - Middle Rear
COMMENTS:Teac cTI
4N K Lit A) - -1 Rdu Wiz.°6. I v
SYSTEM USE APPROVED: YES NO
Arrived: 'Z 5
Departed:
Building 'Inspector
• I jjoA (518) 761-8256
e
TOWN OF QUEENSBURY
BUILDING & CODE ENFORCEMENT n ,
742 BAY D. , QUEENSBURY NY 12804 ,i 1'
INSPECTOR'S REP RT: ARR 1:`t1-) DEPARTt� IN3; '
REQUEST FOR INS CTIO. RECEIVED: 9 li'9 7
NAME '/ LA •L_Ce-G , `rAY d.r>—
l
/ i /
LOCATION , -1 Z�2f i�
DATE q q 7 �/P� p
PERMIT 0 9 1- 4 :'--
TYPE OF ST.UC)URE: ,>4•-/�/1 . b ' '
RECHECK °J APPROVED
' PI YES NO
FOOTINGS/PIERS
r.
MONOLITHIC POUR FORM -
REINFORCEMENT IN PLAC
THE CONTRACTOR IS RESP SIBLE F'
PROVIDING PROTE TION FReM FREEZ
FOR 48 HOURS FOLLOWING T E PLA.'
MEET OF THE CONCRETE.
MATERIALS FOR THIS PURPOS 0
FOUNDATION/WALLPOUR V
REINFORCEMENT IN PLACE
FOUNDATION/DAMPPROOFING l _ I --T/
"CKFILL APPROVAL '1
PLUMBING VENT/VENTS IN PLACE
ROUGH PLUMBING V
PLUMBING UNDER SLAB / I _
FRAMING: / •
JACK STUDS/HEADERS _1
BRACING/BRIDGING _3___
JOIST HANGERS 1
JACK POSTS MAIN BEAM
AIR INFILTRATION ARRIER
HEATING ROUGH-IN
INSULATION:
/
FOUNDATION WALLS INTERIOR R-
FOUNDATIONIWALLS EXTERIOR R- _ 1
FLOORS / R- I
WALLS / R- I
CEILING I R- \
DUCT WORK OR PIPING IN 1
UNHEATE/D!` SPACES R- •
1
�`� �./v.trV (518) :6 ,256
e
TOWN OF QUEENSBURY
BUILDING & CODE ENFORCEMENT i.
742 BAY RD., QUEENSBURY NY 12804 '}
INSPECTOR'S REPORT: ARR/t DEPART / INT
' r
REQUEST FOR PECTION REC IVE
•
NAME �U.`
LOCATION
DATE PERMIT R 1-
TYPE OF TRU TURE:
RECHECK APPROVED/
N/A YES NO
JeTINGS/PIERS \t
MONOLITHIC POUR FORM _ / -
REINFORCEMENT IN PLACE I � �
THE CONTRACTOR IS RESPONI:•LE OR
PROVIDING PROTE TION FRO F.E*ZING
FOR 48 HOURS FOLLOWING TH CE-
MENT OF THE CONCRETE. ``
MATERIALS FOR THIS PURPOSE 4 .ITE
FOUNDATION/WALLPOUR
REINFORCEMENT IN PLACE
FOUNDATION/DAMPPROOFING
SACKFUL APPROVAL
PLUMBING VENT/VENTS IN PLA E
ROUGH PLUMBING
PLUMBING UNDER SLAB
FRAMING:
JACK STUDS/HEADErS
BRACING/BRIDGING
JOIST HANGERS
JACK POSTS/MAIN BEAM -�—
AIR INFILTRATION BARRIE' \
HEATING ROUGH-IN
INSULATION:
FOUNDATION WALLS INT RIOR R- L
FOUNDATION WALLS EXT:RIOR R-
FLOORS R-
WALLS R- - - 1
CEILING R- 1
DUCT WORK OR PIPING I
UNHEATED SPACES R-
II
i
I HEREBY CERTIFY THAT THIS MAP WAS PREPARED
FROM AN ACTUAL FIELD SURVEY.
THIS CERTIFICATION SHALL RUN ONLY TO THE PERSONS
FOR WHOM THE SURVEY WAS PREPARED, AND ON THEIR
BEHALF TO THE TITLE COMPANY, GOVERNMENTAL AGENCY
AND LENDING INSTITUTION LISTED HEREON.
ONS TUTIONSOR SUBSE(�UENTOWNERS
TRANSFERABLEIFICA71ONS ARE NOT TO ADDITIONAL
I
CERTIFIED TO: RICHARD P. SCHERMERHORN, JR.
EVERGREEN BANK, N.A.,
IT'S SUCCESSORS AND\OR ASSIGNS
FIRST AMERICAN TITLE INSURANCE COMPANY
CERTIFIED BY:
NATTHEW C. STEVES, LLS NYS 50135
DATED: SEPTEMBER 11, 1997
Z
O
CL
U
to
W
4
Q
4
O
Z
P4
O-Z
z
W
0
W
b
c
w
O
co •
:r%
0
a�
�
b
a
DaW SEPTEMOM it W
scale r-w
S --1
SHEET10F1
NO. 89316-12