IM%20Inspection%20Worksheet_13-07-2023_14-06-13INSPECTION WORKSHEET (PTI-026444-2023) PT-0234-2023Case Number:Case Module:Permit Management 07/13/2023 Partial PassInspection Status:Inspection Date: Property Transfer InspectionsInspection Type:Inspector:Charles Dyer Job Address:Parcel Number:10 Irongate Rd Queensbury, NY 12804 316.9-1-21 Company Name NameContact Type Primary Owner Robert Alden Checklist Item CommentsPassed Building Inspector Notes False 6/29/23 Property Transfer Inspection Not Approved The items listed below are the reasons for the inspection not being performed. 1) Both ends of the septic tank were not exposed for inspection plus the distribution box was not exposed. These are required for the inspection to be performed as stated on the Property Transfer inspection Application see attached highlighted section. 2) Stone Industries men were told by the homeowner to just open one end of septic tank and did not have time in their schedule to dig up the other two locations. They would have to be rescheduled and their boss Dean Burdick would have to come out and dig up the three locations. 3) Please coordinate a new time with Stone Industries. Weather/lack of information/inaccessibility True no Holding tank (if yes, include capacity)True no Capacity in gallons True 1000 gallon System/components indicate unacceptable False yes / D-box Is there a high water alarm?True Roof gutters don't discharge over leach field True no Concrete tank True yes / 1000 gallon Temperature (Fahrenheit)True 80 D-box material: concrete or plastic False concrete Baffle & D-box or 45° angle True Visible scum layer True yes Septic tank (include # of tanks)True one Number of tank compartments False Plumbing fixtures tested & confirmed True Evidence of a pipe bypassing tank True no System appears undersized/undersized components True no Speed levers in D-box True yes Is there evidence of surface water infiltrating True no Tank cover True System appears to have functioned adequately True System passes all function testing False Outlet pipe (automatic failure, if yes)True no Does the pump(s) appear to be operating properly?True System needs repairs False yes / replacement of D-box July 13, 2023 Page 1 of 2 INSPECTION WORKSHEET (PTI-026444-2023) Checklist Item CommentsPassed Sump pump not connected to septic system True no Outflow line invert above leach line invert(s)?True Depth below grade to top of tank True 10 inches Evidence of prolonged high liquid level True no Access riser? (if yes, depth to cover)True no Inlet baffle True Recommend upgrade/expand/replace 1+ components False yes / replace D-box No treatment tank/other critical component(s)True no Number of drop box(es)True none As-built provided is accurate False no Test each fixture flow to septic tank True Is tank pumped more than 4x/year?True no On-site as-built req'd before insp is complete True Are both switch and alarm operable?True Solids in D-box False yes Ejector or grinder pump sealed True Outlet baffle True Weather True partly sunny 7/13 Main tank cleanout size and location True 20+ inches Evidence of liquid above outlet inverts?True no Absorption field True yes Leaking water fixtures True no Cracked, corroded or deformed?False yes Water tight tank True Other False Are there any obvious electrical shortcomings?True no July 13, 2023 Page 2 of 2