IM Inspection Worksheet_24-07-2023_15-26-11INSPECTION WORKSHEET (SEP-026750-2023) RC-0360-2022Case Number:Case Module:Permit Management 07/24/2023 PassedInspection Status:Inspection Date: SepticInspection Type:Inspector:Charles Dyer Job Address:Parcel Number:373 West Mountain Rd Queensbury, NY 12804 308.9-1-11 Company Name NameContact Type Applicant Mark Reichen Contractor Fine Home Building Granted Permission Jessalie Reichen Primary Owner Jessalie Reichen Mark Reichen Checklist Item CommentsPassed Building Inspector Notes True asbuilt provided by installer Soil Type: Sand True Size of Stone True #2 Waterline separation distance True Building to Tank True 4" SCHD 40 [Provide extension collar if Yes]False Tank to Distribution Box True SDR 35 4" Opening Sealed:True End Cap True lines are looped Absorbtion Fields: Total Length True 20x40 absorbtion bed Foundation to Tank True 12 ft Engineer Report and As-Built True asbuilt provided by installer Location of system on property True right side of garage looking at front of home Inlet & Outlet manholes 12"+ below grade False Type of Water: Municipal / Well Water True municpal Locations / Separations True Depth of Trenches True bed is 16"- 18" Length of Each Trench True 4 lines at 35 ft looped at 5 ft = 155 ft System Use Status True Conforms as per Plot Plan False Size of tank True 1500 Distribution box to Field / Pit True 4" SDR 35 Foundation to Absorption True 23 ft InletOutlet Pipes & Baffles True Soil Type: Loam True July 24, 2023 Page 1 of 1