IM Inspection Worksheet_24-07-2023_15-40-37INSPECTION WORKSHEET (RESFINAL-026758-2023)
RC-0860-2021Case Number:Case Module:Permit Management
07/24/2023 PassedInspection Status:Inspection Date:
Residential Final InspectionInspection Type:Inspector:Charles Dyer
Job Address:Parcel Number:15 Tuscarora Dr
Queensbury, NY 12804
239.8-1-44
Company Name NameContact Type
Applicant William Mason
Contractor Takundewide Management Group Inc. (TMG INC)
Granted Permission Lisa Paplanus
Primary Owner Lisa Paplanus
Checklist Item CommentsPassed
Low flow toilet 1.3 gal/flushing cycle True
Bathroom Fans, if no window True
3" Plumbing Vent through roof minimum 18 inch True
Grade away from foundation: 6" down, 10' out True
Window guards req:<2' above floor/6' above grade True
Interior privacy/trim/doors/main entrance 36 True
Backflow Preventors where required True
Attic Access Insulation = Attic R- Value True
Platform at all exterior doors True
Inter Connected True
Arc Fault Breaker Habitable Spaces True
Furnace/Hot Water Heater operating True
Outside every bedroom area True
Fin Elect; Energy Saving Light Bulbs 90 Percent True Provide final electrical inspection / received
OK to Issue C/O True
Truss ID Signage Installed at Electrical Meter True
4 inch Building Number Address visible from road True
Attic Access Gasketed True
Propane Tank: Proper Setback from Prop Line/Struct True
Every level, Every bedroom True
Furnace shut-off w/in 30 ft. or w/in line of site True
Chimney Height / B Vent / Direct Vent Location True
within 10' of all sleeping areas True
Relief Valve ,Heat Trap/Water Temp 110 deg or less True
Bathroom / Kitchen Watertight True
As Built Septic System True
Battery backup True
Handrail 4 or more risers True
Encl. Stairs Sheetrock Underside minimum ½ Gypsum True Provide 1/2" Sheetrock as discussed under stairs
Verified
Attic Access 22 x 30 minimum True
July 24, 2023 Page 1 of 2
INSPECTION WORKSHEET (RESFINAL-026758-2023)
Checklist Item CommentsPassed
Handrail Termination at Newell Post or Wall True
Roof Complete / Exterior Finish Complete True
Interior/Exterior Railings 34 to 38 True
General Comments True For 2nd floor addition, pre CO walk through 6/3/22
3' from Baths True
Smoke Detectors:True
Guard at stairwell at 34" or more True
Carbon Monoxide Detectors:True
Plumbing fixtures True
July 24, 2023 Page 2 of 2