Loading...
IM Inspection Worksheet_08-08-2023_13-40-18INSPECTION WORKSHEET (SEP-027068-2023) SEP-0431-2023Case Number:Case Module:Permit Management 08/08/2023 Partial PassInspection Status:Inspection Date: SepticInspection Type:Inspector:Mark Smith Job Address:Parcel Number:55 Richardson St Queensbury, NY 12804 309.15-1-64.1 Company Name NameContact Type Applicant TenEyck Septic Service Inc. Contractor TenEyck Septic Service Inc. Engineer Kevin Hastings Granted Permission 55 Richardson Street LLC Primary Owner 55 Richardson Street LLC Checklist Item CommentsPassed Building Inspector Notes False 8/8/23 partial approval of septic system. provide as built drawing from design engineer. - existing 1000 gallon septic tank with a replacement absorbtion field of 3 laterals at 50 each. system is gravity feed. engineer on site at time of inspection Soil Type: Sand True Size of Stone True # 2 Roof gutters don't discharge over leach field True Waterline separation distance True Building to Tank True existing Tank to Distribution Box True 4" sanitary line Opening Sealed:True End Cap True Absorbtion Fields: Total Length True 150' Foundation to Tank True 20' Engineer Report and As-Built False provide as built drawing Location of system on property True left side yard Type of Water: Municipal / Well Water True municipal water supply Locations / Separations True Depth of Trenches True 12"/ 14" Length of Each Trench True 3 laterals at 50' each, 150' total System Use Status True system approved for use Conforms as per Plot Plan True Size of tank True 1000 gallon septic tank Distribution box to Field / Pit True 4" sanitary line perforated Foundation to Absorption True 20' InletOutlet Pipes & Baffles True August 08, 2023 Page 1 of 1