Loading...
CC-0107-2023 i ' 3ffice Use Only ADDITION/ALTERATION PERMIT Permit#: Cc,-d��� Town ofcLeensauty APPLICATION permit Fee:$ 742 Bay Road,Queensbury,NY 12804 P:SM761-8256 www.ciueensbury.net Invoice Flood Zone? Y N Reviewed By: Project Location: 9 Carey Road p 308 16-2-2.3 Tax Ma ID#: Subdivision Name: PROJECT INFORMATION: BARTo WN 9 5 TYPE: ❑ Residential B Commercial,Proposed Use: _ P1 d1 a���, ❑ Single-Family ❑Two-Family ❑ Multi-Family(#of units_) ❑Townhouse B Business Office ❑ Retail ❑ Industrial/Warehouse ❑ Garage(#of cars _ ) ❑ Other(describe ) ADDITION SQUARE FOOTAGE: ALTERATION SQUARE FOOTAGE: 1st floor: 1st floor: 5627 2nd floor: 2nd floor: Wd floor: 31d floor: Basement(habitable space): Basement(habitable space): Total sq ft: Total sq ft: 5627 Scope of work to be done: Renovation of existing office space into new offices. Addition/Alteration Application Revised June 2022 ADDITIONAL PROJECT INFORMATION: 1. Estimated Cost of Construction:$ 350,000 2. Source of Heat(circle one): ® Gas ❑ Oil ❑ Propane ❑ Solar ❑Other: Fireplaces/inserts need a separate Fuel Burning Appliances & Chimney Application 3. Are there any structures not shown on the plot plan? ❑YES ® NO Explain: 4. Are there any easements on the property? ❑YES H NO SITE INFORMATION: is this a corner lot? ig YES ❑ NO • Will the grade be changed as a result of the construction? ❑YES 59 NO • What is the water source? IQ PUBLIC ❑ PRIVATE WELL • What type of wastewater system is on the parcel? W SEWER ❑ PRIVATE SEPTIC DECLARATION: 1. 1 acknowledge that no construction shall be commenced prior to the issuance of a valid permit and will be completed within a 12 month period.Any changes to the approved plans prior to/during construction will require the submittal of amended plans,additional reviews and re-approval. 2. If,for any reason,the building permit application is withdrawn,30%of the fee Is retained by the Town of Queensbury.After 1 year from the initial application date,100%of the fee is retained. 3. If the work is not completed by the 1 year expiration date the pem-it may be renewed, subject to fees and department approval. 4. 1 certify that the application, plans and supporting materials are a true and a complete statement and/or description of the work proposed,that all work will be performed in accordance with the NYS Building Codes,local building laws and ordinances, and in conformance with local zoning regulations. 5. 1 acknowledge that prior to occupying the facilities proposed 1, or my agents, will obtain a certificate of occupancy. 6. 1 also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. 1 have read and agree to the above: PRINT NAME: Chris �Toumie SIGNATURE: C DATE: A/1r � Addition/Alteration Application Revised June 2022 CONTACT INFORMATION: PLEASE PRINT LEGIBLY OR TYPE, PLEASE INCLUDE AN EMAIL • Applicant: Name(s):. Hudson Headwaters Health Network Mailing Address, C/S/Z: 9 Carey Road Queensbury NY 12804 Ceil'Phone: 518857-3408 Land Line: ! _)518761-0300x31624 Email:dvalentlni@hhhn.org _ • Primariy 0wner(s): Name(s): Hudson Headwaters Health Network Mailing Address, C/S/Z: 9 Carey Road Queensbury NY 12804 Cell Phone: (. _)518 857-3408 Land Line: �!)518 761-0300 x 31624 Email:dvalentini@hhhn.org ❑ Check if all work will be performed by property owner only Contractor(s): (List all additional contractors on the back of this form) Contact Name(s): Contractor Trade: Mailing Address, C/S/Z: Cell Phone:. Land Line: ( ) Email: "Workers' Comp documentation must be submitted with this application" Architects)/Eneineer(s): Business Name: sMRT Contact Name(s): Mrianne Morganstein Mailing Address, C/S/Z: 433 State Street5th Floor Cell Phone: )504 90M160 Land Line: 518 978-4922 Email:AMorganstein@smrtlnc.com Contact Person for Compliance in regards to this project: Dal Valentin! Cell Phone: '( _)518 857-3408 Land Line: )518 761-0300 x 31624 Email:dvalentini@hhhn.ore Addition/Alteration Application Revised June 2022 J � i' .8 COMcheck Software Version 4.1.5.5 Interior Lighting Compliance Certificate Project Information Energy Code: 2020 NYStretch Energy Code-2018 IECC FILE ro Project Title: Hudson Headwaters Health Network Project Type: Alteration Construction Site: Owner/Agent: Designer/Contractor: 9 Carey Road Hudson Headwaters Health GPI Queensbury, NY 12804 Network 80 Wolf Road 9 Carey Road Albany, NY 12205 Queensbury, NY 12804 Allowed Interior Lighting Power A B C D Area Category Floor Area Allowed Allowed Watts (ft2) Watts/ft2 (B X C) 1-Health Care-Clinic 5700 0.68 3876 Total Allowed Watts= 3876 Proposed Interior Lighting Power A B C D E Fixture ID : Description/Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D) Fixture Fixtures Watt. Health Care-Clinic(5700 sq.ft.) LED 1:L1-8':PENDANT LED LINEAR:Other: 1 27 58 1566 LED 2:L1-16':PENDANT LED LINEAR:Other: 1 1 116 116 LED 3:L1-20':PENDANT LED LINEAR:Other: 1 6 145 870 LED 4:UA-8':PENDANT LED LINEAR:Other: 1 3 46 138 LED 5:UA-12%PENDANT LED LINEAR:Other: 1 2 69 138 LED 6:UA-20':PENDANT LED LINEAR:Other: 1 2 115 230 LED 7:L1 B-4':PENDANT LED LINEAR:Other: 1 1 38 38 LED 8:L1 B-8%PENDANT LED LINEAR:Other: 1 4 76 304 LED 9:L2:RECESSED 2X2 LED:Other: 1 16 28 448 Total Proposed Watts= 3848 LightingInterior PASSES Interior Lighting Compliance Statement Compliance Statement. The proposed interior lighting alteration project represented in this document is consistent with the building plans,specifications, and other calculations submitted with this permit application.The proposed interior lighting systems have been designed to meet the 2020 NYStretch Energy Code-2018 IECC requirements in COMcheck Version 4.1.5.5 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Franklin Rapp Elec. Designer gumfi&t Rapp 01/04/2023 Name-Title Signature Date REVIEWED FOR ENERGY CODE COMPLIANCE Project Title: Hudson Headwaters Health Network Report date: 01/04/23 Data filename: E:\2022\2200176.00 HHHN 9 Carey Road\ComCheck\20230103 HHHN 9 CAREY RD Page 1 of 7 COMCHECK.cck a COMcheck Software Version 4.1.5.5 Inspection Checklist Energy Code: 2020 NYStretch Energy Code - 2018 IECC Requirements: 72.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement,the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed.Where compliance is itemized in a separate table, a reference to that table is provided. Section # Plan Review Complies? Comments/Assumptions & Re .ID C103.2 ;Plans,specifications,and/or ;❑Complies :Requirement will be met. [PR4]1 calculations provide all information ;❑Does Not with which compliance can be ; Not Observable determined for the interior lighting sand electrical systems and equipment �❑Not Applicable ; Rand document where exceptions to ; ;the standard are claimed. Information ; provided should include interior 1 `lighting power calculations,wattage of bulbs and ballasts,transformers and ;control devices. C405.11 ;New parking garages and new parking ;❑Complies ;Exception: Requirement does not apply. [PR38]3 :lots powered by the energy services ;❑Does Not ;for a building,and with 10 or greater ;parking spaces, provide either: 1. :❑Not Observable Panel capacity and conduit for the 1❑Not Applicable ;future installation of minimum ;208/240V 40-amp outlets for 5 ;percent of the total parking spaces ;and not less than two parking spaces; ; {or 2. Minimum 208/240V 40-amp ; outlets for 5 percent of the total 1 parking spaces and not less than two ; ;parking spaces. ; Additional Comments/Assumptions: 1 I High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Hudson Headwaters Health Network Report date: 01/04/23 Data filename: E:\2022\2200176.00 HHHN 9 Carey Road\ComCheck\20230103 HHHN 9 CAREY RD Page 2 of 7 COMCHECK.cck Section # Rough-in Electrical Inspection I Complies? Comments/Assumptions &Req.ID C405.2.2. ;Spaces required to have light- ;❑Complies ;Requirement will be met. 2 reduction controls have a manual ;❑Does Not [EL22]1 ;control that allows the occupant to : !reduce the connected lighting load in ;❑Not Observable �a reasonably uniform illumination ,❑Not Applicable ;pattern >= 50 percent. C405.2.1, ;Occupancy sensors installed in ;❑Complies ;Requirement will be met. C405.2.1. classrooms/lecture/training rooms, :❑Does Not 1 ;conference/meeting/multipurpose [EL18]1 !rooms, copy/print rooms, []Not Observable corridor/transition areas, ;❑Not Applicable ;lounges/breakrooms,enclosed offices, lopen plan office areas, restrooms, ; storage rooms, locker rooms, ; "warehouse storage areas, and other Ispaces<=300 sqft that are enclosed ; :by floor-to-ceiling height partitions. ;Reference section language lC405.2.1.2 for control function in :warehouses and section C405.2.1.3 ;for open plan office spaces. ; C405.2.1. ;Occupancy sensors control function in ;❑Complies ;Exception: Requirement does not apply. 2 ;warehouses: In warehouses,the ;❑Does Not [EL19]1 ;lighting in aisleways and open areas is, ;controlled with occupant sensors that ;❑Not Observable :automatically reduce lighting power ❑Not Applicable ;by 50%or more when the areas are ; unoccupied.The occupant sensors !control lighting in each aisleway ;independently and do not control ; lighting beyond the aisleway being controlled by the sensor. C405.2.1. !Occupant sensor control function in ;❑Complies :Requirement will be met. 3 :open plan office areas: Occupant :❑Does Not [EL20]1 ;sensor controls in open office,spaces 1❑Not Observable {>= 300 sq.ft, have controls 1) :configured so that general lighting can,❑Not Applicable ;be controlled separately in control ;zones with floor areas <=600 sq.ft. ; :within the space, 2)automatically turn: ;off general lighting in all control zones ; Iwithin 20 minutes after all occupants :have left the space, 3) are configured so that general lighting power in each ; control zone is reduced by>=80%of ;the full zone general lighting power ;within 20 minutes of all occupants !leaving that control zone, and 4)are ;configured such that any daylight ; ;responsive control will activate space ; :general lighting or control zone ;general lighting only when occupancy ; ;for the same area is detected. C405.2.2, ;Each area not served by occupancy I❑Complies !Exception: Lighting controlled by occupancy sensors. C405.2.2. i sensors(per C405.2.1) have time- PDoes Not 1, ;switch controls and functions detailed C405.2.2. ;in sections C405.2.2.1 and C405.2.2.2.;❑Not Observable 2 ;❑Not Applicable ; [EL21]z : ; 1 I High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Hudson Headwaters Health Network Report date: 01/04/23 Data filename: E:\2022\2200176.00 HHHN 9 Carey Road\ComCheck\20230103 HHHN 9 CAREY RD Page 3 of 7 COMCHECK.cck Section # Rough-In Electrical Inspection Complies? Comments/Assumptions &Req.ID C405.2.3, ;Daylight zones provided with ;❑Complies ;Exception: Requirement does not apply. C405.2.3. !individual controls that control the !❑Does Not 1, ;lights independent of general area !❑Not Observable C405.2.3. ;lighting within daylight zones in the , 2 !following spaces: 1.Spaces with a []Not Applicable [EL23]2 ;total of more than 100 watts of ; general lighting within sidelit zones !complying with Section C405.2.3.2. ;General lighting does not include ; lighting that is required to have ; ;specific application control in ;accordance with Section C405.2.4. 2. ; !Spaces with a total of more than 100 ; ;watts of general lighting within toplit ;zones complying with Section lC405.2.3.3.See code section ! :C405.2.3.1 Daylight responsive ;control function and section ! C405.2.4 Separate lighting control devices for i❑Complies ;Requirement will be met. [EL26] !specific uses installed per approved !❑Does Not lighting plans. ;❑Not Observable: j !❑Not Applicable ! C405.2.4 ;Additional interior lighting power ;❑Complies ;Requirement will be met. [EL27]1 !allowed for special functions per the !❑Does Not ;approved lighting plans and is ;automatically controlled and :❑Not Observable; !separated from general lighting. !❑Not Applicable C405.3 i Exit signs do not exceed 5 watts per ;❑Complies :Requirement will be met. [EL6]1 !face. !❑Does Not ;❑Not Observable: ❑Not Applicable C405.6 ;Low-voltage dry-type distribution ;❑Complies [EL26].2 ;electric transformers meet the !❑Does Not ;minimum efficiency requirements of ;Table C405.6. ;❑Not Observable; ❑Not Applicable C405.7 ;Electric motors meet the minimum ;❑Complies [EL27]2 ;efficiency requirements of Tables !❑Does Not C405.7(1)through C405.7(4). ❑Not Observable; Efficiency verified through certification; under an approved certification !❑Not Applicable program or the equipment efficiency ratings shall be provided by motor ; ;manufacturer(where certification ;programs do not exist). ; C405.8.2 ;Escalators and moving walks comply ;❑Complies ; [EL28]2 with ASME A17.1/CSA B44 and have !❑Does Not !automatic controls configured to ; reduce speed to the minimum :❑Not Observable permitted speed in accordance with !❑Not Applicable ASME A17.1/CSA B44 or applicable !local code when not conveying passengers. ! C405.9 ;Total voltage drop across the ;❑Complies [EL29]2 !combination of feeders and branch !❑Does Not ;circuits <=5%. C-INot Observable; !❑Not Applicable Additional Comments/Assumptions: 1 I High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Hudson Headwaters Health Network Report date: 01/04/23 Data filename: E:\2022\2200176.00 HHHN 9 Carey Road\ComCheck\20230103 HHHN 9 CAREY RD Page 4 of 7 COMCHECK.cck 1 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Hudson Headwaters Health Network Report date: 01/04/23 Data filename: E:\2022\2200176.00 HHHN 9 Carey Road\ComCheck\20230103 HHHN 9 CAREY RD Page 5 of 7 COMCHECK.cck Section # Final Inspection Complies? Comments/Assumptions &Req.ID C303.3, ;Furnished O&M instructions for ;❑Complies ;Requirement will be met. C408.2.5. !systems and equipment to the ;❑Does Not 2 ;building owner or designated ; [FI17]3 `representative. :❑Not Observable; ;❑Not Applicable ; C405.4.1 (Interior installed lamp and fixture ;❑Complies ;See the Interior Lighting fixture schedule for values. [FI18]1 blighting power is consistent with what ❑Does Not is shown on the approved lighting `plans, demonstrating proposed watts ;❑Not Observable; :are less than or equal to allowed ;❑Not Applicable ; watts. C408.1.1 'Building operations and maintenance ;❑Complies ; [F]57]1 :documents will be provided to the E❑Does Not owner. Documents will cover ,manufacturers' information, ❑Not Observable :specifications, programming ,❑Not Applicable ;procedures and means of illustrating ; Ito owner how building, equipment and; !systems are intended to be installed, ;maintained,and operated. C408.3 ;Lighting systems have been tested to ;❑Complies ;Requirement will be met. [FI33]1 !ensure proper calibration,adjustment, ;❑Does Not ;programming,and operation. ,❑Not Observable, ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Hudson Headwaters Health Network Report date: 01/04/23 Data filename: E:\2022\2200176.00 HHHN 9 Carey Road\ComCheck\20230103 HHHN 9 CAREY RD Page 6 of 7 COMCHECK.cck Project Title: Hudson Headwaters Health Network Report date: 01/04/23 Data filename: E:\2022\2200176.00 HHHN 9 Carey Road\ComCheck\20230103 HHHN 9 CAREY RD Page 7 of 7 COMCHECK.cck T I � I I T1 i MOO A Sustainable Solutions for ,{ Efficient Environments a + s 4 Chelsea Place,Clifton Park, NY 12065 or 694 Colesville Rd,Binghamton NY 13904 Phone:518-450-7292 Fax:518-450-7295 Design Review-Commissioning-Fire Life Safety-Test And Balance-Blower Door Testing-Drone Sales/Inspections/Repairs-ASHRAE 110 Mechanical Testing Inc. specializes in HVAC Test&Balance.We cover areas of the Northeast and National accounts in the US.MTI is ! committed to excellence and saving our customers money.We service a diverse group of facilities such as medical,chemical, ( manufacturing,schools,defense,office buildings and more.We now offer drone sales and solutions to enterprise companies to have automation help improve your profits and revenues.We are a certified NYS WBE,WOSB and WBENC. I I What sets MTI apart from the competition? ✓ Our people have more certifications and training compared to our competition. ✓ We pride ourselves on customer service and satisfaction! ✓ Updated equipment encompassing the latest technology to keep up with trends. ✓ Paperless reporting solutions for quicker turnaround and sneak peeks. ✓ We take out the pain for our customers by assisting with coordination and follow up. ✓ AABC Certified:guarantees the work is done right or they send someone else to fix it! i ✓ We have been in business for 53 years since 1967! Core Capabilities Our Certified Commissioning Authorities&Test and Balance Field Engineers will research,test,and implement solutions in the areas of: ✓ Third Party Commissioning(New,Retro or Continued Cx) ✓ Troubleshoot HVAC systems and sequences of operation ✓ Adjust Air Flow and Certify ✓ Adjust Water Balance and Certify ✓ Energy Audits ✓ ASHRAE 110,Fume Hood Testing and Certification ✓ Clean Room Testing and Certification ✓ Sound&Vibration Testing �. 0 ✓ Duct Leakage Tests/Duct Pressurization/Decay Testing F I LE a0v ✓ Indoor Air Quality ✓ Fire Life Safety(Fire Damper Testing) ✓ DJI Drone Authorized Dealer and Repair Center ✓ Drone Inspections Energy,Power Lines,etc. ✓ Thermal Imaging of Buildings ✓ 3D Scanning of Environments for BIM&RIVET applications ✓ Blower Door Testing ✓ Aerial Photography ✓ Thermography i I f' Energy Our Energy Services focus on integrated solutions designed to enhance the performance of your building by incorporating various tests to ensure that the building is running efficiently. ✓ Duct Leakage Tests ' ✓ Energy Audits ✓ Inspection of HVAC systems ✓ Third Party Commissioning(New,Retro or Continued Cx) �' ✓ Building Envelope scans a Federal Certification WBENC Certification#20051226825 Exp 5/26/21 and WOSB#WOSB191159 Exp 5/26/21 GSA Contract#470SHA20DODIC i State Certifications NYS Certified WBE#8805Exp 2-28-23 NYC Certified Wand SCA Certified WBE Major Clients SUNY Nanofab Albany Co VA Medical Center,NY Albany Medical Center,Albany NY Lourdes Hospital,Binghamton NY ' St.Peters Hospital,Albany NY Ellis Hospital,Schenectady NY rnott Hospital,Bath/Horsehead NY Office of General Services SUNY Albany Fage Global Foundries St.Clare's Hospital,Troy NY SUNY Binghamton SUNY Plattsburgh SUNY Albany College of Pharmacy Champlain Valley Hospital,NY North American Industry Classification System(NAICS)238220 Testing and Balancing and (NAICS)541350,541690 Energy efficiency inspection services(Commissioning),488190 and 541990. UNSPSC,72151200,72151204,81141805 and 81141806 General Information Registered Company Name:Mechanical Testing,Inc. DBA:Mechanical Testing Inc. Year Incorporated:1961 State of Incorporation:New York State Corporation Type:Subchapter S Federal ID 14-1498182 DUNS Number 98356397 GSA#47QSHA20DO01C Cage Code 6AGZ2 CONTACT INFORMATION Voice:(518)450-7292 Fax:(518)450-7295 Email:eileenvC@mechtest.com or Visit our Website:www.mechtest.com Schedule Email:MikemOmechtest.com or Schedule Online Link Estimator:KenMcCfinechtest.com 4 Chelsea Place,Suite 102,Clifton Park,NY 12065 , iMT1 i Sustainable Solutions for Efficient Environments 4 Chelsea Place,Clifton Park, NY 12065 or 694 Colesville Rd,Binghamton NY 13904 i" Phone:518-450-7292 Fax:518-450-7295 { Design Review-Commissioning-Fire Life Safety-Test And Balance-Blower Door Testing-Drone Sales/Inspections/Repairs-ASHRAE 110 li Mechanical Testing Inc. specializes in HVAC Test&Balance.We cover areas of the Northeast and National accounts in the US.MTI is committed to excellence and saving our customers money.We service a diverse group of facilities such as medical,chemical, manufacturing,schools,defense,office buildings and more.We now offer drone sales and solutions to enterprise companies to have j automation help improve your profits and revenues.We are a certified NYS WBE,WOSB and WBENC. f What sets MTI apart from the competition? ✓ Our people have more certifications and training compared to our competition. I ✓ We pride ourselves on customer service and satisfaction! ✓ Updated equipment encompassing the latest technology to keep up with trends. ✓ Paperless reporting solutions for quicker turnaround and sneak peeks. ✓ We take out the pain for our customers by assisting with coordination and follow up. ✓ AABC Certified:guarantees the work is done right or they send someone else to fix it! ✓ We have been in business for 53 years since 1961! Core Capabilities Our Certified Commissioning Authorities&Test and Balance Field Engineers will research,test,and implement solutions in the areas of: ✓ Third Party Commissioning(New,Retro or Continued Cx) ✓ Troubleshoot HVAC systems and sequences of operation ✓ Adjust Air Flow and Certify ✓ Adjust Water Balance and Certify ✓ Energy Audits ✓ ASHRAE 110,Fume Hood Testing and Certification ✓ Clean Room Testing and Certification ✓ Sound&Vibration Testing ✓ Duct Leakage Tests/Duct Pressurization/Decay Testing ✓ Indoor Air Quality ✓ Fire Life Safety(Fire Damper Testing) ✓ D11 Drone Authorized Dealer and Repair Center ✓ Drone Inspections Energy,Power Lines,etc. ✓ Thermal Imaging of Buildings ✓ 3D Scanning of Environments for BIM&RIVET applications ✓ Blower Door Testing ✓ Aerial Photography ✓ Thermography I e i i Energy Our Energy Services focus on integrated solutions designed to enhance the performance of your building by incorporating various tests to ensure that the building is running efficiently. i ✓ Duct Leakage Tests ✓ Energy Audits ✓ Inspection of HVAC systems ✓ Third Party Commissioning(New,Retro or Continued Cx) ✓ Building Envelope scans Federal Certification WBENC Certification#20051226825 Exp 5/26/21 and WOSB#WOSB191159 Exp 5/26/21 GSA Contract#470SHA2OD0OIC I� State Certifications NYS Certified WBE#8805 Exp 2-28-23 NYC Certified WBEand SCA Certified WBE Major Clients SUNY Nanofab Albany Co VA Medical Center,NY Albany Medical Center,Albany NY Lourdes Hospital,Binghamton NY St.Peters Hospital,Albany NY Ellis Hospital,Schenectady NY rnott Hospital,Bath/Horsehead NY Office of General Services t r` SUNY Albany Fage a' Global Foundries St.Clare's Hospital,Troy NY SUNY Binghamton SUNY Plattsburgh a SUNY Albany College of Pharmacy * Champlain Valley Hospital,NY North American Industry Classification System(NAICS)238220 Testing and Balancing and (NAICS)541350,541690 Energy efficiency inspection services(Commissioning),488190 and 541990. UNSPSC,72151200,721512O4,81141805 and 81141806 General Information Registered Company Name:Mechanical Testing,Inc. DBA:Mechanical Testing Inc. Year Incorporated:1967 State of Incorporation:New York State Corporation Type:Subchapter S Federal ID 14-1498182 DUNS Number 98356397 GSA#47QSHA2OD001C Cage Code 6AGZ2 CONTACT INFORMATION Voice:(518)450-1292 Fax:(518)450-7295 Email:eileenvOmechtest.com or Visit our Website:www.mechtest.com Schedule Email:MikemC@mechtest.com or Schedule Online Link Estimator:KenMc@mechtest.com 4 Chelsea Place,Suite 102,Clifton Park,NY 12065 FIRE MARSHAL'S OFFICE Town of Queensbunj (v 742 Bay Road, Queensbury, NY 12804 ac "Home of Natural Beauty ... A -Good Place to Live " PLAN REVIEW HHHN 9 and 27 Carey Road CC-OOXX-2023 2/17/2023 The following comments are based on a review of submittals: • 27 Carey—.no issues • 9 Carey.—verify fire ext locations Verify exit/EL placement and function Provide NFPA 13 letter of compliance for any sprinkler system modifications • Provide NFPA 72 letter of compliance for any changes to the fire alarm system • Contractor to follow provisions of FC Chapter 33 in protecting life safety compone s duri c ftci Michael J Palmer Fire Marshal 742.Bay Road Queensbury NY 12804 firemarshal@queensbury.net Fire Marshal 's Office Phone: 518-761-8206 Fax: 518-745-4437 {iremarshal@queensbum net 707M.queensburil net