Loading...
DEMO-0467-2022 Office Use Only DEMOLITION APPLICATION Permit#: T)EM0— xe, 7 - wad Permit Fee:$ fo�CJa Town of Queensbury Invoice#: Sam 742 Bay Road,Queensbury,NY 12804 P:518-761-8256 www.gueensburV.net Flood Zone? Y Reviewed By: Demolition Location: 756 Upper Glen Street, Suite 4, Tax Map ID#: 523400 302.6-1-51.2 **AN ASBESTOS REPORT IS REQUIRED WITH ALL DEMOLITION APPLICATION SUBMISSIONS** DEMOLITION INFORMATION: 1. Where will demolition material be disposed? Finch Waste Co. 2. Type of structure to be demolished: a. Residence_ d. Storage Building E_ . `8 E b. Garage e. Other: p �{�' c. Business_interior) JUL 2 6 ?02? 3. What type of utilities are connected to the structure: a Gas_X f. Well-Water Pump -('OW N! GF is`'iJE E N'cP,LE`y 4 b. - Fuel Oil g. Public Sewer I �•— - --�—� c. Propane h. Other d. Electric _ i. None e. Public Water X 4. Have ALL utilities (water, electric, etc.) been disconnected? Yes No X ADDITIONAL INFORMATION: 1. Two inspections are required: an inspection to determine that utilities are disconnected, and a final inspection after the structure is removed and the site is cleaned up and graded. 2. Twenty-four (24) hour notification is required for inspections. 3. Workers' Comp insurance information is required to be submitted with this application. Declaration: I acknowledge that no structure(s)will be removed from the parcel until the demolition application has been reviewed and approved by the Town of Queensbury Building&Code Enforcement and Zoning Departments and a permit has been issued. I have read and agree to the above: PRINT NAME: Kevl SIGNATURE: DATE: 07/25/2022 Demolition Application Revised June'2022 CONTACT INFORMATION: PLEASE PRINT LEGIBLY OR TYPE, PLEASE INCLUDE AN EMAIL • Applicant: Name(s): Huntington Construction dba EMCO Construction Mailing Address, c/s/z: 4 Kelch Dr Suite 208 Malta, NY 12020 Cell Phone: (518)857-0058 Land Line: (518)456-1853 Email: kevinha—emcoconstruction.com • Primary Owner(s): Name(s): Ilene Flaum d/b/a Flaum Properties Co. Mailing Address, C/S/Z: 400 Andrews Street, Suite 500, Rochester, NY 14604 Cell Phone: Contact Jerry Griffo: 585-370-6088 Land Line: 585-436-4550 Email: JGriffo@flaummgt.com Check if all work will be performed by property owner only • Contractor: (List all additional contractors on the back of this form) Contact Name(s): Huntington Construction dba EMCO Construction Contractor Trade: General Contractor Mailing Address, c/s/z: 4 Kelch Dr Suite 208 Malta, NY 12020 Cell Phone: (518)857-0058 Land Line: (518)456-1853 Email: kevinhaemcoconstruction com _ **Workers' Comp documentation must be submitted with this application** Contact Person for any questions regarding this project: Kevin Huntington Cell Phone: (518)857-0058 Land Line: (518)456-1853 Email: kevinh(aemcoconstruction.com Demolition Application Revised June 2022 P.0.Box 1024 SPECTRVA Schenectady.NY 12301 (518)348-6374(Phone) Environmental associates, Inc. (518)348-4062(Fax) 'EXCEEDINC ODR CLIENTS EXPECTRrfoNs or EXCELLENCE' www.4spectmm.com LIMITED ASBESTOS RENOVATION SURVEY/INSPECTION FOR 1 fU Gu ? e �2 � 4 10 1P ovpxy up ee0 FORMER TUESDAY MORNING QUEENSBURY PLAZA 756 UPPER GLEN ST QUEENSBURY, NY 12804 SPECTRUM PROJECT NO.: 22-390 m � 0 j rn w 3o 3 rnnN o G) Oo+ o � C r TOWN OF QUEENSBURY �, ! 3 � BUILDING DEPARTMENT 4 t- Based on our limited examination,compliance JULY 149 2022 4 W with our comments shall noec Pica onsuare In o indicating the plans and sp full compliance with the Building Codes of o 0 New York State. 3 PREPARED FOR: 3 o a o O V O QUEENSBURY PLAZA LO C/O FLAUM MANAGEMENT N 400 ANDREWS ST. SUITE 500 FILE Copy ROCHESTER, NY 14604 Environmental Consulting&Management Services • Health&Safety Training • Laboratory Services TABLE OF CONTENTS SECTION I - INTRODUCTION SECTION II -LIMITATIONS SECTION III -ASBESTOS SAMPLING SUMMARY ATTACHMENTS - TABLE 1 -ASBESTOS SAMPLING RESULTS - TABLE 2-ASBESTOS FINDINGS - PHOTO ALBUM -LOCATION MAPS -LABORATORY REPORTS -LICENSING AND CERTIFICATION SECTION I-INTRODUCTION On July 8, 2022, Spectrum Environmental Associates, Inc. (Spectrum) conducted a survey for the presence of asbestos containing materials at the Former Tuesday Morning (Queensbury Plaza) located at 756 Upper Glen St in Queensbury,NY. Mr. Eric Rath(Asbestos Inspector#06-08942) conducted this inspection following procedures and guidelines commonly used and accepted by federal and state regulations. The objective of the survey was to identify the presence and approximate locations and quantities of suspect and/or confirmed asbestos containing materials. An initial walkthrough of the designated areas was conducted by an experienced asbestos inspector to observe and record materials used in the construction of the building. The inspector proceeded by assessing floors, walls, ceilings, surfacing materials, thermal systems insulation, roofing materials and other miscellaneous materials with the potential to contain asbestos. From observations, the inspector prepared a listing of building materials that are suspected to contain asbestos. The inspector selected these materials for inclusion in the inspection through professional experience and an understanding of the historical uses of asbestos. Generally speaking,if a building material within a structure could contain asbestos,the material was included in the inspection. Materials included in the survey were identified and recorded with respect to grouped homogeneous sampling areas. Representative bulk material samples were collected from locations within each homogeneous sampling area. Sampling information was recorded on chain of custody forms for documentation. Samples were individually preserved within a container and transported to an independent laboratory for asbestos analysis. Laboratory analysis of asbestos samples via polarized light microscopy(PLM)and/or transmission electron microscopy(TEM)was conducted by AmeriSci of New York,New York(ELAP# 11480, NVLAP#200546-0). Sample analysis was conducted as follows: • "Friable"Asbestos Samples—PLM • "Non-Friable" Organically Bound (NOB)Asbestos Samples—PLM and, if negative, TEM for confirmation as required under NYSDOH-ELAP regulations. SECTION II-LIMITATIONS The information provided in this report was compiled from field and laboratory data obtained during the site visit. Observations noted and recorded are intended to represent the conditions that existed at the subject site at the time and date that the observations were made. Spectrum has not conducted its own analytical,but has utilized an independent NYS-DOH ELAP approved laboratory to provide the analytical results contained in this report. All discussions, findings, and conclusions are based on information that Spectrum received and understood to be factual. Determinations of suspect asbestos containing materials within the building were subject to the accessibility of individual areas or spaces. Spectrum accepts no responsibility for the content of the building materials within areas or spaces that were unknown to us or not reasonably accessible. Spectrum assumes no liability for any buildings that were not identified by the client that may fall under state or federal regulations. All quantities of ACM provided in this report are provided as required by law and are believed to be accurate. If this report is to be used for bidding purposes, field verification of quantities is recommended by the abatement contractor prior to bidding. Conclusions and recommendations provided in this report are based on the assumption that materials identified are homogeneous throughout their application. This report has been compiled for the exclusive use of Flaum Management Co Inc, its successors and/or assigns. This report and its contents represent confidential information and should not be duplicated without the expressed permission of Flaum Management Co Inc, its successors and/or assigns. SECTION III—ASBESTOS SAMPLING SUMMARY The results of the sampling are provided in Table 1 (Asbestos Sampling Results) and the asbestos findings are provided in Table 2 (Asbestos Findings) of the Attachments. The laboratory results and sample location map(s) are also provided in the Attachments. ATTACHMENTS TABLE I-ASBESTOS SAMPLING RESULTS TABLE 2-ASBESTOS FINDINGS PHOTO ALBUM LOCATIONMAPS LABORATORYREPORTS LICENSING AND CERTIFICATION TABLE I - ASBESTOS SAMPLING RESULTS 756 Upper Glens St. Spectrum Project#22-390 Date Sampled: July 8, 2022 Sample# Description Location/Area PLM Results TEM Results ( Type) ( Type) O1 Sheetrock 1"floor Wall NAD NA 02 Sheetrock 2"d floor Wall NAD NA 03 Joint Compound 111 floor Wall NAD NA 04 Joint Compound 2"d floor Wall NAD NA 05 Floor Tile 151 floor(Floor Rear) NAD NAD 06 Floor Tile V floor(Floor Front) NAD NAD 07 Tile Adhesive lst floor(Floor Rear) NAD NAD 08 Tile Adhesive V floor(Floor Front) NAD NAD 09 Cove Base Adhesive lst floor(Floor Rear) NAD NAD 10 Cove Base Adhesive lst floor(Floor Front) NAD NAD 11 Glazing 2"d floor Windows Chrysotile<0.25% Chrysotile< 1.0% 12 Glazing 2"d floor Windows Chrysotile<0.25% Chrysotile< 1.0% 13 Bathroom Grout 2"d floor Bathroom NAD NA 14 Bathroom Grout 2"d floor Bathroom NAD NA 15 Ceiling Tile V floor Front NAD NAD 16 Ceiling Tile I"floor Rear NAD NAD Note: Asbestos containing materials are greater than 1%asbestos. Trace is considered less than 1%asbestos. NAD-no asbestos detected,NA-not applicable,PS—Positive Stop,SF-square feet,LF—linear feet TABLE 2 - ASBESTOS FINDINGS 756 Upper Glens St. Spectrum Project#22-390 Date Sampled: July 8, 2022 Limitations: The following limitation/conditions were noted as part of the survey: • OSHA requires that an employer not expose its workers above the PEL and therefore specific training, work practices and/or respiratory protection may need to be a consideration when handling materials that are less than one percent. • The inspection was performed in accordance with New York State Industrial Code Rule 56 Section 5.1. A copy of 56-5.1 is available upon request. It is the responsibility of the owner or its agent to forward a copy of this report to the local government entity charged with issuing a permit for such demolition, renovation, remodeling or repair work under applicable State or local laws as well as to the NYS Department of Labor Asbestos Control Bureau. Spectrum will not send this report to the NYSDOL without written permission from its client due to the sensitive nature of the information present in this report. • This report reflects the conditions found at the date and time of the inspection(s). Conditions of the area and materials may change due to external events, forces or influences. Re- inspection of the area may be required prior to the start of any work if an extended period of time has passed or if disturbances have occurred. • If materials not sampled in the survey are uncovered during renovation/demolition,per ICR56 work should stop and those materials should be assessed before work continues. Also per ICR 56, a copy of the survey report should be submitted to the local agency issuing the demolition permit and a copy should be kept on site during the demolition phase of the proj ect. • All asbestos locations on drawings are approximate. All quantities are estimated and must be field verified prior to use as part of a bidding document. Materials may extend or be hidden behind or within other materials or structural members. Any contractor or other user of this report is required to physically confirm the quantities and verify measurements of materials to be removed, to be bid for removal, or for any other purpose. Contractors are responsible to physically visit the site and confirm all quantities for bidding purposes. • This survey is for the future renovation of the structure. Per NYSDOL, if the project does not proceed within approximately 6 months, the structure should be visually re-inspected to confirm that no addition materials have been added and that the existing conditions of the identified ACM is still the same. • Spectrum did not inspect any exterior area below grade. Foundation sealers,buried piping and other items may exist below grade which may contain asbestos. SF—square feet,LF—linear feet,ea—each TABLE 2 — ASBESTOS FINDINGS 756 Upper Glens St. Spectrum Project#22-390 Date Sampled: July 8, 2022 Material Location/Area Estimated Quantity* Condition/Damaged None of the materials tested were positive for asbestos as defined by New York State Department of Labor - Industrial Code Rule 56 (NYS ICR 56) *Quantities of identified ACM are estimates only and should be field verified prior to bid by the contractor or confirmed as part of an RFP or design specification. Please see the limitation listed above. Asbestos%by PLM*-please refer to the PLM Bulk Asbestos Report for the method used. All asbestos locations on drawings are approximate. All quantities are estimated and must be field verified prior to use as part of a bidding document. Materials may extend or be hidden behind or within other materials or structural members. Any contractor or other user of this report is required to physically confinn the quantities and verify measurements of materials to be removed, to be bid for removal, or for any other purpose. Contractors are responsible to physically visit the site and confirm all quantities for bidding purposes. Definitions: NAD—No Asbestos Detected NA—Not Analyzed NA'— SOF-V and SM-V must be analyzed by ELAP 198.8 orequivalent effective 5/6/16 NAZ —Insufficient Material for Preparation N/A—Not Applicable(quantities are not provided for negative materials TBD—To Be Determined(quantification was not possible as the scope of work was notprovided) NA/PS—Not Analyzed/Positive Stop SF—square feet,LF—linear feet,ea—each Asbestos Inspection Photo Album of 756 Upper Glen St . by Spectrum Environmental Associates, Inc. Spectrum Project # 22-390 Date of Inspection: July 8, 2022 r f, �f' raj*•. vl/���"/ �,/r f a, .41 ji IV Eff I r � 1 tc . rlp } I Ilk fir, 4 i 77, i. w is u , 1� 1 r i� �7 p, a• F� Asa a , t i L O CA TION MA P(S) 22-390 (7-8-22) Former Tuesday Morning Store 756 Upper Glen St. Limited Renovation Bulk Sample Locations - NTS 11 13 14 2,4 10 5,7 16 6,8 - 1,3 15 9 LABORATORY REPORTS AmeriSci New York AmERI Scl NEW 117 EAST ST. YORK, NYY 10 10016 TEL:(212)679-8600• FAX:(212) 679-3114 PLM Bulk Asbestos Report Spectrum Environmental Associates, Inc. Date Received 07/09/22 AmeriSci Job # 222071921 Attn: Bill Massman Date Examined 07/13/22 P.O. # P.O.Box 1024 ELAP# 11480 Page 1 Of 4 RE:22-390; Former Tuesday Morning St.; 756 Upper Glen St., Schenectady, NY 12301 Queensb. Client No. / HGA Lab No. Asbestos Present Total %Asbestos 1 222071921-01 No NAD 1 Location: 1st Floor Wall-Sheetrock (by NYS ELAP 198.1) by Valeriu Voicu on 07/13/22 Analyst Description:White, Homogeneous, Fibrous, Bulk Material Asbestos Types: Other Material: Cellulose 2%, Non-fibrous 98% 2 222071921-02 No NAD 1 Location:2nd Floor Wall-Sheetrock (by NYS ELAP 198.1) by Valeriu Voicu on 07/13/22 Analyst Description:White, Homogeneous, Fibrous, Bulk Material Asbestos Types: Other Material: Cellulose 1%, Non-fibrous 99% 3 222071921-03 No NAD 2 Location: 1st Floor-Joint Compound (by NYS ELAP 198.1) by Valeriu Voicu on 07/13/22 Analyst Description:White, Homogeneous, Non-Fibrous, Bulk Material Asbestos Types: Other Material: Cellulose Trace, Non-fibrous 100% 4 222071921-04 No NAD 2 Location:2nd Story-Joint Compound (by NYS ELAP 198.1) by Valeriu Voicu on 07/13/22 Analyst Description:White, Homogeneous, Non-Fibrous, Bulk Material Asbestos Types: _ Other Material:.Cellulose Trace, Non-fibrous 100% 5 222071921-05 No NAD 3 Location: 1 st Story Floor Rear-Floor Tile (by NYS ELAP 198.6) by Valeriu Voicu on 07/13/22 Analyst Description:Gray, Homogeneous, Non-Fibrous, Bulk Material Asbestos Types: Other Material: Non-fibrous 24.7% See Reporting notes on last page AmeriSci Job#: 222071921 Page 2 of 4 Client Name:Spectrum Environmental Associates, Inc. PLM Bulk Asbestos Report 22-390; Former Tuesday Morning St.; 756 Upper Glen St., Queensb. Client No. / HGA Lab No. Asbestos Present Total %Asbestos 6 222071921-06 No NAD 3 Location: 1 st Story Floor Front-Floor Tile (by NYS ELAP 198.6) by Valeriu Voicu on 07/13/22 Analyst Description:Gray, Homogeneous, Non-Fibrous, Bulk Material Asbestos Types: Other Material: Non-fibrous 24.8% 7 222071921-07 No NAD 4 Location: 1 st Story Floors-Tile Adhesive (by NYS ELAP 198.6) by Valeriu Voicu on 07/13/22 Analyst Description:Gray/Black, Heterogeneous, Non-Fibrous, Bulk Material Asbestos Types: Other Material: Non-fibrous 14.6% 8 222071921-08 No NAD 4 Location: 1 st Story Floors-Tile Adhesive (by NYS ELAP 198.6) by Valeriu Voicu on 07/13/22 Analyst Description:Gray/Black, Heterogeneous, Non-Fibrous, Bulk Material Asbestos Types: Other Material: Non-fibrous 14.6% 9 222071921-09 No NAD 5 Location: 1 st Floor Front-Cove Base Adhesive (by NYS ELAP 198.6) by Valeriu Voicu on 07/13/22 Analyst Description:Tan, Homogeneous, Non-Fibrous, Bulk Material Asbestos Types: Other Material: Non-fibrous 15.8% 10 222071921-10 No NAD 5 Location: 1 st Floor Rear-Cove Base Adhesive (by NYS ELAP 198.6) by Valeriu Voicu on 07/13/22 Analyst Description:Tan, Homogeneous, Non-Fibrous, Bulk Material Asbestos Types: Other Material: Non-fibrous 12.1% 11 222071921-11 Yes Trace (<0.25 % pc) 6 Location:2nd FI.Windows-Glazing (ELAP 400 PC) by Valeriu Voicu on 07/13/22 Analyst Description:Gray, Homogeneous, Non-Fibrous, Bulk Material Asbestos Types:Chrysotile <0.25% pc Other Material: Non-fibrous 4.5% See Reporting notes on last page AmeriSci Job#: 222071921 Page 3 of 4 Client Name:Spectrum Environmental Associates, Inc. PLM Bulk Asbestos Report 22-390; Former Tuesday Morning St.; 756 Upper Glen St., Queensb. Client No. / HGA Lab No. Asbestos Present Total %Asbestos 12 222071921-12 Yes Trace (<0.25 % pc) 6 Location:2nd FI.Windows-Glazing (ELAP 400 PC) by Valeriu Voicu on 07/13/22 Analyst Description:Gray, Homogeneous, Non-Fibrous, Bulk Material Asbestos Types:Chrysotile <0.25% pc Other Material: Non-fibrous 5.5% 13 222071921-13 No NAD 7 Location:2nd FI. Bathroom-Bathroom Grout (by NYS ELAP 198.1) by Valeriu Voicu on 07/13/22 Analyst Description:White, Homogeneous, Non-Fibrous, Bulk Material Asbestos Types: Other Material: Cellulose Trace, Non-fibrous 100% 14 222071921-14 No NAD 7 Location:2nd FI. Bathroom-Bathroom Grout (by NYS ELAP 198.1) by Valeriu Voicu on 07/13/22 Analyst Description:White, Homogeneous, Non-Fibrous, Bulk Material Asbestos Types: Other Material: Cellulose Trace, Non-fibrous 100% 15 222071921-15 No NAD 8 Location: 1 st Floor Front-Ceiling Tile (by NYS ELAP 198.6) by Valeriu Voicu on 07/13/22 Analyst Description:White/Beige, Homogeneous, Non-Fibrous, Bulk Material Asbestos Types: Other Material: Non-fibrous 47.7% 16 222071921-16 No NAD 8 Location: 1st FI. Rear-Ceiling Tile (by NYS ELAP 198.6) by Valeriu Voicu on 07/13/22 Analyst Description:White/Beige, Homogeneous, Non-Fibrous, Bulk Material Asbestos Types: Other Material: Non-fibrous 51.4% See Reporting notes on last page AmeriSci Job#: 222071921 Page 4 of 4 Client Name:Spectrum Environmental Associates, Inc. PLM Bulk Asbestos Report 22-390; Former Tuesday Morning St.; 756 Upper Glen St., Queensb. Reporting Notes: (1) Sample prepared for analysis by ELAP 198.6 method Analyzed by:Valeriu Voicu Reviewed by:Gabriella Morozov Date:7/13/2022 *NAD/NSD=no asbestos detected;NA=not analyzed;NA/PS=not analyzed/positive stop,(SOF-V)=Sprayed On Fireproofing containing Vermiculite; (SM-V) =Surfacing Material containing Vermiculite;PLM Bulk Asbestos Analysis using Olympus,Model BH-2 Pol Scope,Microscope,Serial#:229915,by Appd E to Subpt E,40 CFR 763 quantified by either CVES or 400 pt ct as noted for each analysis(NVLAP 200546-0),ELAP PLM Method 198.1 for NY friable samples,which includes the identification and quantitation of vermiculite,or ELAP 198.6 for NOB samples,or EPA 400 pt ct by EPA 600- M4-82-020(NY ELAP Lab 11480);Note:PLM is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. NAD or Trace results by PLM are inconclusive,TEM is currently the only method that can be used to determine if this material can be considered or treated as non asbestos-containing in NY State(also see EPA Advisory for floor tile,FR 59,146,38970,8/1/94)National Institute of Standards and Technology Accreditation requirements mandate that this report must not be reproduced except in full without the approval of the Iab.This PLM report relates ONLY to the items tested.RI Cert AAL-094,CT Cert PH-0186,Mass Cert AA000054,N1 Lab ID #NY031. END OF REPORT AmeriSci Job#: 222071921 Page 1 of 2 Client Name: Spectrum Environmental Associates, Inc. Table I Summary of Bulk Asbestos Analysis Results 22-390; Former Tuesday Morning St.; 756 Upper Glen St., Queensb. Sample Heat Acid Insoluble AmeriSci HG Weight Sensitive Soluble Non-Asbestos **Asbestos%by **Asbestos%by Sample# Client Sample# Area (gram) Organic% Inorganic% Inorganic% PLWDS TEM 01 1 1 -- -- --_ ---- NAD NA Location: 1st Floor Wall-Sheetrock 02 2 1 --- -- - --- NAD NA Location: 2nd Floor Wall-Sheetrock 03 3 2 ---- ---- - -- NAD NA Location: 1st Floor-Joint Compound 04 4 2 --- --- -- -- NAD NA Location: 2nd Story-Joint Compound 05 5 3 0.315 19.4 55.8 24.7 NAD NAD Location: 1 st Story Floor Rear-Floor Tile 06 6 3 0.308 18.7 56.6 24.8 NAD NAD Location: 1 st Story Floor Front-Floor Tile 07 7 4 0.258 28.1 57.3 14.6 NAD NAD Location: 1st Story Floors-Tile Adhesive 08 8 4 0.240 28.3 57.1 14.6 NAD NAD Location: 1st Story Floors-Tile Adhesive 09 9 5 0.362 43.5 40.7 15.8 NAD NAD Location: 1st Floor Front-Cove Base Adhesive 10 10 5 0.223 42.6 45.3 12.1 NAD NAD Location: 1 st Floor Rear-Cove Base Adhesive 11 11 6 0.279 9.4 86.2 4.3 Chrysotile<0.25 Chrysotile<1.0 Location: 2nd Fl.Windows-Glazing 12 12 6 0.225 14.4 80.1 5.3 Chrysotile<0.25 Chrysotile<1.0 Location: 2nd Fl.Windows-Glazing 13 13 7 ---- -- ---- --- NAD NA Location: 2nd Fl.Bathroom-Bathroom Grout 14 14 7 -- -_ __ ___ NAD NA Location: 2nd Fl. Bathroom-Bathroom Grout 15 15 8 0.218 27.5 24.8 47.7 NAD NAD Location: 1st Floor Front-Ceiling Tile 16 16 8 0.234 29.4 19.2 51.4 NAD NAD Location: 1 st Fl.Rear-Ceiling Tile See Reporting notes on last page AmeriSci Job#: 222071921 Page 2 Of 2 Client Name: Spectrum Environmental Associates, Inc. Table Summary of Bulk Asbestos Analysis Results 22-390; Former Tuesday Morning St.; 756 Upper Glen St., Queensb. Sample Heat Acid Insoluble AmeriSci HG Weight Sensitive Soluble Non-Asbestos **Asbestos%by **Asbestos%by Sample# Client Sample# Area (gram) Organic% Inorganic% Inorganic% PLM/DS TEM Analyzed by:Gabriella Morozov Reviewed by:Gabriella Morozov Date:7/13/2022 **Quantitative Analysis(Semi/Full);Bulk Asbestos Analysis-PLM by Appd E to Subpt E,40 CFR 763 or NYSDOH ELAP 198.1 for New York friable samples or NYSDOH ELAP 198.6 for New York NOB samples; TEM(Semi/Full)by EPA 600/R-93/116(or NYSDOH ELAP 198A;for New York samples).Analysis using Hitachi,Model H600-Noran 7 System,Microscope,Serial#:542-26-10.NAD=no asbestos detected during a quantitative analysis;NA=not analyzed;Trace= <1%,(SOF-V) =Sprayed On Fireproofing containing Vermiculite;(SM-V)=Surfacing Material containing Vermiculite;Quantitation for beginning weights of<0.1 grams should be considered as qualitative only;Qualitative Analysis:Asbestos analysis results of"Present'or"NVA= No Visible Asbestos"represents results for Qualitative PLM or TEM Analysis only(no accreditation coverage available from any regulatory agency for qualitative analyses):NVLAP(PLM)200546-0, NYSDOH ELAP Lab 11480,NJ Lab ID #NY031. Warning Note:PLM limitation,only TEM will resolve fibers <0.25 micrometers in diameter.TEM bulk analysis is representative of the fine grained matrix material and may not be representative of non- uniformly dispersed debris for which PLM evaluation is recommended(i.e.soils and other heterogenous materials). f TR. IPO.l ox 4 024 Schenectady,[1 V 12301 SP C. I 222 07 2 (5a�)346-6374(Phone) L 7 1 �. (513)34 -4062(,Fax) 1f'I.-Wav par,04rar Cuvrry B97BNB AspectP7 m.com ]BULK SAMPLING CHAIN OF ECIUSTOD Y (Itev,03107/2014) PROJECT INFO1ZMk..C1ON Project,f� _ -�� lWidingNamo; o r or ! s Matrix Analysis Requested Turnaround Data Sampled: Area/Location: �f 7-8°,2 M,Paint u PLM-BLAP 198.1 7EM-ELAP 198.4 ® RUST-I ® 24IIour Page lF of I Investigator. C i 0 Soil ® wipe • PLM-I;LAI'198.6 ® 72 Flour q SAwLl;JTDrNTIT-TCATION ti Sample ID#: Group#:* Material Sample Location Condition/Comment � I 1 J. IBaC �i T,' t J� o t-—&-s e- k i o v- F(o \- l3 (3a r r • Unless othorivise stnted pleaso nnalrze Inch group to first(1't positivo result 7nts: `y C13Aw or,CUSTODY Relinquished By .Date Time Received By Date Time Method of Submittal 1 L2 CI � l u ? 2Z �2 lI . III Environmental Consulting a& Aanagement Services ° ,health d Sat'etV Training Laboratory Services LICENSING AND CERTIFICATION P.a Bon lo24 SPECTRVA Schenectady,NY 12301 (518)346-0374(Phone) Envimnmental dssoclates, Inc. (518)3464062(Fax) 'EXCeEwNc OVR CLIENTS EXPECTATIONS OF EXCELLENCE' wwm4spectrumxom State of New York— Department of Labor Asbestos Certification STATE OF NEW YORK-.DEPARTMENT&; ABOR;, ? ASEeS 6s cEknFICATE ERICX RATH_`- ' .. 'CLASS(E)(PIRES) CATEC(64�22).`D IWS (04/22): H PM (04/22)' 3 I DINIV4 726818, MUST BE CARRIED ON`ASBESTOS 0R07ECTS nainuanniMill aie11- IIIII II IIIIII IIII�IIIIIII II� IF FOUND RETURN TO: { EYES BLU NYSDOL - L&C UNIT p HAIR BAL ROOM 161A BUILDING 12 a HGT 5' 08" STATE OFFICE CAMPUS $ ALBANY NY 12240 n B N �O r State of New York — Department of Labor Codes Certification A Asbestos Handler B Restricted Handler - Allied Trades C Air Sampling Technician D Inspector E Management Planner F Operations and Maintenance G Supervisor H Project Monitor I Project Designer Environmental Consulting&Management Services a Health d.Safety Training • Laboratory Services New-York State Department'of.Labof --•` + A Division of Safety and Health, License and Certfcate/lJnit!% State Campus,Building 12 f' Albany,.NY 12240 S HANDLING LICENSE-, Spectrum Environmental Associates,`Inc; ", y~ -:FILE NUMBER: 9910129, ; `�.' w rr'• >`: �; LICENSE NUMBER:'29081_:'r. <' \ \ I LICENSE CLASS: RESTRICTED—`) •)•'J=7P:,0: Box�1024 :�• -�;� s'i .,�,r � , _r DATE OF ISSUE: 02/02/2022 ,? ✓ = s ,Sck nectady,,NY 1A'01 = }'yri' . { EXPIRATION DATE: 02/28/2023 `� t fJ a_ C s + '`:: y31 r fff } r i y -- 1 I ,fi ! i 'f•,�'�-"e•`,'`— _ --'sty'''.�.i;' �5.� Id.�,� 1.�. f � f: Duly,,Authorized Representativex.—,'VUilliam`LiMassmann;:<`J ryi ;� `N � • ,-� RP �.y..i,^t��:,.:� f,i,J,.'�,•�.,�.w}t'•-,�.N,�k `" k� (y i� 7 I This license'lias been issued in acpcp'ordance with apphcalile prouisi'ons�of Artic1ea30.'of the Labor Law of New York'S-i and of 1 the New York-State,Codes,Rules�ndkegulationsJ(12 NYCRR Part 56):'It-is-,subject to suspension or revocation`tor a(1) f` seriousviolation of state,federal or local laws with�regard-to;the conduet''of an'asbestos project,or(2)demonsirate"d.:lack-of f t � 1 i •�t\'.a.'`^' "o ,t.•-avx;=t'i't`Aka'`�',ft (�I ,I!�i l� r`^,lam'-•M^ responsibility m the.conduct of any job/invol'virig;asbesfos or,asbestos`matenal:''•�� This license is valid only,for'tlie contractor named;aboue and this'ji&use or.a photocopy.must.be-.promirieritly displayed at the asbestos project-worksite.`'\Th s 1 ense verifies that -persons employed.by the licensee on ar asbesto`s,.proje`ctin NeW York State have beeri-issued an Asbestos Certificate,-appropriate for the type'_of work they perform,by the'New York 5tate� / Department of Labor. t Amy Phillips,Director SH 432(8/12) For the Commissioner of Labor • _ .____N_EW YORE STATE DEPARTMENT OF HEALTH - _ - WADSWORTH CENTER = -- - _ i=xpires 12-01 AM Aprit GT,Z023 Issued April 01, 2022 _ - CERTIFICATE OF APPROVAL FOR LABORATORY SERVICE Issued in accordance with and pursuant to section 502 Public Health Law of New York State AAR. PAUL f-MUCHA NY Lab Id No: 11480 . = AMERICA SCIENCE TEAM NEW YORK, INC = _ 117 EAST 30TH ST NEW YORK, NY 10016 -- _ is hereby APPROVED as an Environmental Laboratory for tha-category ENVIRONMENTAL ANALYSES SOLID AND HAZARDOUS WASTE = - All approved-subcategories andlar.analytes are listed below _ 1fteatlaneous - Asbestos-in Ffla1le-Material Item 198.1 of Manual EPA 600/M4/82/020 Asbestos irfflon-Friable Material-OLM Item 198.6 of Manual(NOB by PLM)- Asbestos in Non-Friable Material-TEM Item 198.4 of Manual SeHal No.: 64683 Property of the New York State Department of HeaTth. Certificates are valid only at ft address = shaWn,must be conspicuously posted,and are printecr sesue paper. Continued accreditation depends -5--oh successful ongoing_partletpation in the Program. Consumers are urged to call(518)485-5570 tc- verify the laboratorys accreditation status. -- - Panty 1 of 1 a .d o r co DEMOLITION DEMOLITION PLAN SCALE: 1 /8" = 1'-0" GENERAL NOTES - Omer4 of these docurrwh wWm the drawings and specWtions ore irrstrrnrerrts of service for the project 121031 and M remain the property of the kd&d wh*w the project for 40 they ore node is executed or not They are not to be used an ony other project, except by writer aunaria6On of fhe ardrieCt. - M dime ions ere to foce of stud, or face of concrete rrasorwy wA or to center of *"/door unless ofherwise noted. - Due to the printing process these *u6ngs ore not reproduced to scale. DO NOT SCALE 00M - The suing profe.W%W of fhis document is not order contract for project a knirdAm or construction review and, therefore, assumes no responshlly for deviations from time docwnents. M motaids o d products to be intakd per nmloctm instructions. Design and mftcbon shot conform to the &"q Code, k ft ing Code, M edmical Code, Fire Cade, Fuel Gas Code of New York Stye. Controcior to reify al drawing 6mcesions. V.I.F. t161'-7" V.I.F. f163'-54" SHEET INDEX REV SHEET # SHEET NAME 1 2 3 4 5 A-1 DEMOLITION S-0 STRUCTURAL NOTES S-1 STRUCTURAL FRAMING PLAN AND SECTION BUILDING CODE ANALYSIS OCCUPANCY CLASSIFICATION BUILDING GROSS S.F. CONSTRUCTION TYPE FIRE PROTECTION SYSTEM TYPE n b PROVIDED PER NFPA 13 CODE ANALYSIS: THIS PROJECT IS FOR INTERIOR DEMOLITION OF AN EXISTING MERCANTILE SPACE. WORK INCLUDES REMOVAL OF AN EXISTING MEZZANINE A SEPARATE BUILDING PERMIT APPLICATION SHALL BE MADE OF NEW CONSTRUCTION WORK. LEGEND NEW DOOR DOOR IS PART OF BUILDING SHELL WORK EXISTING PARTITION PARTITION TO BE REMOVED ---------------- FELL COPY c� Q ire- �e6 TO'v'JN Or OUKNSBUR)" BUILDING DEPARTMENT Based on our limited examination, compliance with our comments shall not be construed as indicating the plans and specifications are in full compliance with the Building Codes of New York State. 302.6-1-51.2 DEMO-0467-2022 EMCO Construction 756 Glen St Demolition interior (former Tuesday Morning) i W 0 F- eV) N zgw>- ZZ D w �.mQ- m < U) a- (1) W W ww(C)w >>U-) ::) F— CY r- CY U w O d� a m d� z -• 0 0° Wt H� Cn ato 0 M tg _L0 Zw z :2V) O U F- w O w lY d- :2 (f)�- Z zw� Q (Y w �o� Z Q r 00 LL- d- cr M Cy m � Y m m CD 0 w _Z U Q w z o 0 IZ z 0 I-- (0 �LLJ 04 N J u7 O ON 0 o z .: N Ld N Q (.0 p o 77 O U Z w w � U ~ W a_ W 0 REVISIONS NO. DATE DESCRIPTION • s.. `.r' .. o. pao.ry a w Ifr sra�r s llrsd ir.rrrr A�e+R�. fr .r Apr r .� r�r�...t lea rw. wrr..r a ry.0 ti Mwara. y tlr irYt d ■r Ivw • �� a d� Uw Ur� rd bm pmw* ew � ee�Mrr w Ir � � Y d��iwt� N Lei! W yr �Yro� fiat M �M �N ow1iM�� rI0w1 Yy rIM� r'�� UMa M11 .wew �Mrr M Yi rwr� r r .I�Iwe� ..05=7,. DRAWING NO. A-1