IM Inspection Worksheet_18-09-2023_11-55-22INSPECTION WORKSHEET (SEP-027639-2023) SEP-0746-2022Case Number:Case Module:Permit Management 09/15/2023 Partial PassInspection Status:Inspection Date: SepticInspection Type:Inspector:Mark Smith Job Address:Parcel Number:22 Ward Ln Queensbury, NY 12804 240.6-1-6 Company Name NameContact Type Applicant David Barlow Engineer Hutchins Engineering Granted Permission David Barlow Primary Owner David Barlow Checklist Item CommentsPassed Building Inspector Notes False 4/27/23 partial approval for septic system - placement of two 1500 gallon poly holding tank approved, ok to back fill. Call for recheck when remaining components of septic system are installed. 5/26/23 partial approval for septic system - connection of 2" forced main at holding tank verified - connection of the two holding tanks with 4" SDR 35 verified. Ok to back fill holding tanks. Items remaining - verify pump tank and alarms are operational. - verify alarms and water shut off solenoid are operational at holding tank. -provide as built drawing from design engineer at completion of installation of septic system. - provide proof of final electrical inspection ( at completion of project) 9/15/23 Septic System Partial Approval of Holding Tank System Components Only! - alarms and shut off solenoid verified. - alarms at grinder pump verified. - proof of final electric verified. Items remaining - Submit certified as-built drawing from design engineer Final Electrical True Commonwealth Waterline separation distance True Building to Tank True 2" Pump line from grinder pump in residence to holding #1 Tank to Distribution Box True 4" SCH40 PVC from holding tank #1 to holding tank #2 Opening Sealed:True 90% alarm level activates True Foundation to Tank True September 18, 2023 Page 1 of 2 INSPECTION WORKSHEET (SEP-027639-2023) Checklist Item CommentsPassed Engineer Report and As-Built False 9/15/23 Septic System Partial Approval of Holding Tank System Components Only! - alarms and shut off solenoid verified. - alarms at grinder pump verified. - proof of final electric verified. Items remaining - Submit certified as-built drawing from design engineer Water shut off activates at 90% full True Location of system on property False 9/15/23 Septic System Partial Approval of Holding Tank System Components Only! - alarms and shut off solenoid verified. - alarms at grinder pump verified. - proof of final electric verified. Items remaining - Submit certified as-built drawing from design engineer Type of Water: Municipal / Well Water True Lake water supply System Use Status False 9/15/23 Septic System Partial Approval of Holding Tank System Components Only! - alarms and shut off solenoid verified. - alarms at grinder pump verified. - proof of final electric verified. Items remaining - Submit certified as-built drawing from design engineer Conforms as per Plot Plan False 9/15/23 Septic System Partial Approval of Holding Tank System Components Only! - alarms and shut off solenoid verified. - alarms at grinder pump verified. - proof of final electric verified. Items remaining - Submit certified as-built drawing from design engineer Size of tank True 2 1500 gallon holding tanks InletOutlet Pipes & Baffles True 50% alarm level activates True September 18, 2023 Page 2 of 2