IM Inspection Worksheet_25-09-2023_11-48-19INSPECTION WORKSHEET (POOL-027885-2023)
POOL-0120-2023Case Number:Case Module:Permit Management
09/25/2023 PassedInspection Status:Inspection Date:
PoolInspection Type:Inspector:Charles Dyer
Job Address:Parcel Number:12 Fox Hollow Ln
Queensbury, NY 12804
295.19-3-36
Company Name NameContact Type
Applicant Bonnie Huffaker
Contractor Pools Plus
Granted Permission Bonnie Huffaker
Primary Owner Kirk Huffaker
Checklist Item CommentsPassed
Self closing device or alarms (30 sec Alarm time)True
Building Inspector Notes False Received electrical inspection / please call 518-761-8207 to set
time and date for pool inspection by TOQ code enforcement.
Thank you
Suction outlt must be protected agst user entrpmnt True
Final Electrical True
Pool enclosure around pool or yard True around pool
2 inch max to grade from underside of fence True
Pool Surface Motion Alarm True
Bottom pool drain vacuum relief system-REQUIRED True
Padlock provided on gates or ladder True On gate
4 feet above grade True
4 inch maximum clearance in fence pickets True
Timer on pool pump (no plug in timer allowed)True switch
Ok to issue CC True
Gate opens outward, self closing True
September 25, 2023 Page 1 of 1