IM Inspection Worksheet_01-11-2023_08-06-13INSPECTION WORKSHEET (COMFIN-028626-2023) CC-0061-2023Case Number:Case Module:Permit Management 11/01/2023 Partial PassInspection Status:Inspection Date: Commercial Final InspectionInspection Type:Inspector:Mark Smith Job Address:Parcel Number:756 Glen St Queensbury, NY 12804 302.6-1-51.2 Company Name NameContact Type Applicant JET Enterprises HC3 LLC Contractor JET Enterprises TSC2 LLC Granted Permission Dave's Hot Chicken Primary Owner QUEENSBURY PLAZA I, LLC Checklist Item CommentsPassed Low flow toilet 1.3 gal/flushing cycle True Building Inspector Notes False 10/27/23 final commercial inspection not approved. Please address the items listed below and call for recheck when ready. - One hour fire rated wall that separates the kitchen from storage area will need to be repaired and fire caulking and rockwool installed at the roof deck and at all penetrations. - 2 hour fire rated wall at corridor leading to back door needs to be fire caulked at open penetrations. - Provide a certified letter of substantial completion from design engineer stating that the project was completed in accordance with the approve3d plans and specifications. - Install missing ceiling tiles in kitchen ceiling. - provide air balancing report. -install handicapped signs at restrooms. -provide electronic as built drawings. -install 4" building numbers at front door. - Complete Fire Marshall's Items. 11/1/23 partial approval for final commercial inspection. - Approved for temporary Certificate of Occupancy only. remaining items. -Submit air balancing report. -Submit electronic as built drawings Bldg Access All Sides 20ft Drivable Surface True H/C rear grab bar 36" with 24" to open side True Public Toilet Room Handicapped Accessible True Firewalls, 2 Hr, 3 Hr / Fire Dampers / Fire Doors True Handicap parking striping True Bldg Num or Tenant Address on Bld or Drive True Gas Shut-off Exposed & Regulator 12" min abv grd True Handicapped Service Counters 34 inch True H/C side & rear grab bars 36" above floor True HVAC air balancing report False provide air balancing report H/C sinks 34" above floor True H/C 18" minimum vertical grab bar True Engineer or Architect Approval True Hot water drain pan to indirect waste True November 01, 2023 Page 1 of 2 INSPECTION WORKSHEET (COMFIN-028626-2023) Checklist Item CommentsPassed H/C grab bar: 42" side, 12" from center True OK to Issue C/O False Universal Symbol of Access displayed True Final Electrical / Flex Gas Piping Bonded True Plumbing Vent Through Roof/Roof complete True Relief Valve ,Heat Trap/Water Temp 110 deg or less True Electronic as-builts False provide electronic as built drawings Handicapped Bath/Parking Lot Signage True Exits At Grade Or Platform 36 (w) x 44 (l)True H/C mirrors 40" above floor True H/C toilet flush handle on open side True OK to Issue Temporary C/O False 11/1/23 approved for temp C.O only H/C vertical grab bar 39" from floor and corner True Ext Finish /Grade Complete/6 in 10ft or Equivalent True Doors 36 inch wLever Hand Panic Hardware, if req True Attic Access 30 x 20 x 30 (h)True Floor Bathroom Watertight Other Floors Okay True November 01, 2023 Page 2 of 2