IM Inspection Worksheet_31-10-2023_13-04-02INSPECTION WORKSHEET (RESFINAL-028165-2023)
RC-0603-2022Case Number:Case Module:Permit Management
10/31/2023 FailedInspection Status:Inspection Date:
Residential Final InspectionInspection Type:Inspector:Charles Dyer
Job Address:Parcel Number:72 John St
Queensbury, NY 12804
301.17-2-36
Company Name NameContact Type
Applicant Matt Breault
Granted Permission Terri Parker
Primary Owner Terri Parker
Checklist Item CommentsPassed
bedroom(s) with gas appliances False
Low flow toilet 1.3 gal/flushing cycle False
Bathroom Fans, if no window False
3" Plumbing Vent through roof minimum 18 inch False
Grade away from foundation: 6" down, 10' out False
Final Survey Plot Plan False
Sewer Dept. Inspection Sticker False
Window guards req:<2' above floor/6' above grade False
Interior privacy/trim/doors/main entrance 36 False
Backflow Preventors where required False
Basement wall insulation R- value verified False
Emergency egress below grade False
Fuel Tanks above flood plain elevation False
Intake Openings False
Safety glazing: w/in 5' of tub/shower False
Site Plan / Variance required False
Seals on Garage Doors, esp. Wood False
Not less than 3' horiz from opening of bthrn False
Basement ceiling covered 2x8 fl joist or less False
Attic Access Insulation = Attic R- Value False
Gas Shut-off Exposed & Regulator 12" min abv grd False
Platform at all exterior doors False
Fireblocking at fl joist 80 s.f. or less False
Garage Floor Pitched False
Buried Fuel Tanks anchored in flood zone False
Wood deck: 2'+ from grade dia bracing required False
Inter Connected False
Arc Fault Breaker Habitable Spaces False
Dryer Duct Max Length 35', Labeled Over 35'False
Energy Sticker on Elec. Panel:R-Val. & Heating Sys False
Furnace/Hot Water Heater operating False
Hot water drain pan to indirect waste False
October 31, 2023 Page 1 of 3
INSPECTION WORKSHEET (RESFINAL-028165-2023)
Checklist Item CommentsPassed
Fresh Air Intake False
Chimney Rain Cap Installed False
Basement stairs closed rise greater than 4 inches False
Foam in basement/attics covered w/thermal barrier False
Outside every bedroom area False
Oil Furnace Shut-Off at Entrance to Furnace Area False
Blower Door Test Certification False
Fin Elect; Energy Saving Light Bulbs 90 Percent False
Heat detector in garage False
Gas Log In Sealed or Glass Enclosure False
OK to Issue C/O False
Truss ID Signage Installed at Electrical Meter False
Range Hood 400+ cfm-Fresh Air REQUIRED False
4 inch Building Number Address visible from road False
CO in bedrooms w/gas appliances False
HVAC Vent Terminal 10' from Lot Line & Openings False
Attic Access Gasketed False
Jack posts in basement lagged at top and bottom False
Flood Plain Certification, if required False
Guard at deck, porches 36" or more False
6" clearance to sill plate False
Crawl space/knee wall access insulated & gasketed False
5/8" Type X with Living Space Above False
1/2" Gypsum-Bsmt Ceiling<2x10 Frame/TJI/Fl. Truss False
Knee wall/Crawl space 18" x 24"False
Chimney Height / B Vent / Direct Vent Location False
Plumbing fixtures False
Guards at stairs,decks,patios 30" + above grade False
Interior/Exterior Railings 34 to 38 False
Electronic as-builts False
As Built Septic System False
General Comments True Matt, if this project is completed, please call 518-761-8207 to set
up time and date for final inspection. Thank you / CD
Roof Complete / Exterior Finish Complete False
Propane Tank: Proper Setback from Prop Line/Struct False
Handrail 4 or more risers False
Floor truss, draft stop- fin base 1,000 sq. ft.False
Encl. Stairs Sheetrock Underside minimum ½ Gypsum False
Basement Egress: 5s.f. window w/sill or Bilco door False
Handrail Termination at Newell Post or Wall False
Furnace shut-off w/in 30 ft. or w/in line of site False
Relief Valve ,Heat Trap/Water Temp 110 deg or less False
October 31, 2023 Page 2 of 3
INSPECTION WORKSHEET (RESFINAL-028165-2023)
Checklist Item CommentsPassed
Battery backup False
Pull down stairs boxed out and insulated False
Low water shut-off boiler False
Foundation insulation to floor False
Deck Ledger-Bolted per Code False
20 Minute Fire Door/Self-Closing Hardware False
Attic Access 22 x 30 minimum False
Fresh air supply 3' from grade False
HRV or ERV Installed per Bedroom Requirements False
All Hot Water Systems: 3/4" or larger piping R-3 False
OK to Issue Temporary C/O False
Outside Spigots have Air Gap False
Smoke Detectors:False
on all levels w/gas appliances (i.e. furnace)False
Bathroom / Kitchen Watertight False
4+ Deck Joist Ledger Connections-24" From Ends False
within 10' of all sleeping areas False
Flex Gas Pipe Bonding False
Carbon Monoxide Detectors:False
1/2" Gypsum or House Wall and Gable False
CSST/other piping in conduit if buried,if required False
Every level, Every bedroom False
Duct work sealed properly False
Guard at stairwell at 34" or more False
October 31, 2023 Page 3 of 3